GSM/EDGE BSS, Rel. RG20(BSS), Operating Documentation, Issue 09 CI - Internal Routing States DN00260704 Issue 3-0 Confidential Nokia Siemens Networks is continually striving to reduce the adverse environmental effects of its products and services. We would like to encourage you as our customers and users to join us in working towards a cleaner, safer environment. Please recycle product packaging and follow the recommendations for power use and proper disposal of our products and their compo- nents. If you should have questions regarding our Environmental Policy or any of the environmental services we offer, please contact us at Nokia Siemens Networks for any additional information.

Upload: anonbnr

Post on 24-Oct-2015

22 views

Category:

Documents


1 download

DESCRIPTION

CI - Internal Routing States

TRANSCRIPT

Page 1: Dn 00260704

GSM/EDGE BSS, Rel. RG20(BSS), Operating Documentation, Issue 09

CI - Internal Routing States

DN00260704

Issue 3-0

Confidential

Nokia Siemens Networks is continually striving to reduce the adverse environmental effects of its products and services. We would like to encourage you as our customers and users to join us in working towards a cleaner, safer environment. Please recycle product packaging and follow the recommendations for power use and proper disposal of our products and their compo-nents.

If you should have questions regarding our Environmental Policy or any of the environmental services we offer, please contact us at Nokia Siemens Networks for any additional information.

Page 2: Dn 00260704

2 DN00260704

CI - Internal Routing States

Id:0900d805806fcfd8Confidential

The information in this document is subject to change without notice and describes only the product defined in the introduction of this documentation. This documentation is intended for the use of Nokia Siemens Networks customers only for the purposes of the agreement under which the document is submitted, and no part of it may be used, reproduced, modified or transmitted in any form or means without the prior written permission of Nokia Siemens Networks. The documentation has been prepared to be used by professional and properly trained personnel, and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes customer comments as part of the process of continuous development and improvement of the documentation.

The information or statements given in this documentation concerning the suitability, capacity, or performance of the mentioned hardware or software products are given "as is" and all liability arising in connection with such hardware or software products shall be defined conclusively and finally in a separate agreement between Nokia Siemens Networks and the customer. However, Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions contained in the document are adequate and free of material errors and omissions. Nokia Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which may not be covered by the document.

Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO EVENT WILL Nokia Siemens Networks BE LIABLE FOR ERRORS IN THIS DOCUMENTA-TION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDI-RECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION IN IT.

This documentation and the product it describes are considered protected by copyrights and other intellectual property rights according to the applicable laws.

The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark of Nokia Corporation. Siemens is a registered trademark of Siemens AG.

Other product names mentioned in this document may be trademarks of their respective owners, and they are mentioned for identification purposes only.

Copyright © Nokia Siemens Networks 2012. All rights reserved

f Important Notice on Product SafetyThis product may present safety risks due to laser, electricity, heat, and other sources of danger.

Only trained and qualified personnel may install, operate, maintain or otherwise handle this product and only after having carefully read the safety information applicable to this product.

The safety information is provided in the Safety Information section in the “Legal, Safety and Environmental Information” part of this document or documentation set.

The same text in German:

f Wichtiger Hinweis zur Produktsicherheit Von diesem Produkt können Gefahren durch Laser, Elektrizität, Hitzeentwicklung oder andere Gefahrenquellen ausgehen.

Installation, Betrieb, Wartung und sonstige Handhabung des Produktes darf nur durch geschultes und qualifiziertes Personal unter Beachtung der anwendbaren Sicherheits-anforderungen erfolgen.

Die Sicherheitsanforderungen finden Sie unter „Sicherheitshinweise“ im Teil „Legal, Safety and Environmental Information“ dieses Dokuments oder dieses Dokumentations-satzes.

Page 3: Dn 00260704

DN00260704 3

CI - Internal Routing States

Id:0900d805806fcfd8Confidential

Table of contentsThis document has 20 pages.

Summary of changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

CI - INTERNAL ROUTING STATES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

CI - INTERNAL ROUTING STATES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

CIM MODIFY INTERNAL CIRCUIT OR CIRCUIT GROUP STATE . . . . 8

CII INTERROGATE INTERNAL CIRCUIT OR CIRCUIT GROUP STATE 12

CIC MODIFY INTERNAL ROUTE STATE. . . . . . . . . . . . . . . . . . . . . . . 17

CIL INTERROGATE INTERNAL ROUTE STATE . . . . . . . . . . . . . . . . . 19

Page 4: Dn 00260704

4 DN00260704

CI - Internal Routing States

Id:0900d805806fcfd8Confidential

Page 5: Dn 00260704

DN00260704 5

CI - Internal Routing States Summary of changes

Id:0900d805806fcff9Confidential

Summary of changesChanges between document issues are cumulative. Therefore, the latest document issue contains all changes made to previous issues.

Changes made between issues 3-0 and 2-0Parameter ETPCM added to commands CIM and CII.

Changes made between issues 2-0 and 1–1The switch parameter removed. ETSI information added.

Changes made between issues 1–1 and 1-0Combined issue including both ETSI and ANSI information.

Page 6: Dn 00260704

6 DN00260704

CI - Internal Routing States

Id:0900d80580628a65Confidential

CI - INTERNAL ROUTING STATES

CI - INTERNAL ROUTING STATESYou can use the commands of the command group to handle the states of internal circuits or circuit groups and outgoing routes.

Menu of the command group:

INTERNAL ROUTING STATES COMMANDS

? ..... DISPLAY MENUM: ..... MODIFY INTERNAL CIRCUIT OR CIRCUIT GROUP STATEI: ..... INTERROGATE INTERNAL CIRCUIT OR CIRCUIT GROUP STATEC: ..... MODIFY INTERNAL ROUTE STATEL: ..... INTERROGATE INTERNAL ROUTE STATEZ; ..... RETURN TO MAIN LEVEL

Page 7: Dn 00260704

DN00260704 7

CI - Internal Routing States CI - INTERNAL ROUTING STATES

Id:0900d80580628aacConfidential

CI - INTERNAL ROUTING STATESThe commands in this command group are:

CIM MODIFY INTERNAL CIRCUIT OR CIRCUIT GROUP STATE

CII INTERROGATE INTERNAL CIRCUIT OR CIRCUIT GROUP STATE

CIC MODIFY INTERNAL ROUTE STATE

CIL INTERROGATE INTERNAL ROUTE STATE

Page 8: Dn 00260704

8 DN00260704

CI - Internal Routing States

Id:0900d805806fcffcConfidential

CIM MODIFY INTERNAL CIRCUIT OR CIRCUIT GROUP STATE

CIM MODIFY INTERNAL CIRCUIT OR CIRCUIT GROUP STATE

Function Use this command to modify the state of one or several internal circuit groups or circuits.

Parameters circuit group name, circuit group number, circuit(s), bit based circuit(s) (European Tele-communications Standards Institute (ETSI)): circuit group state, circuit(s) state;

Syntax CIM: ( NCGR = <circuit group name>... |

CGR = <circuit group number>... |

ETPCM = <et-pcm>|

CRCT = <circuit(s)>... |

BCRCT = <bit based circuit(s)>... ) :

If NCGR or CGR given:

( WO | BA | TE );

If CRCT given:

( WO | BA );

Parameter explana-tions

circuit group name

NCGR = the name of the circuit group whose state is to be changed

You can use the '&' symbol to give several circuit groups at the same time.

circuit group number

CGR = the number of the circuit group whose state is to be changed

The possible values range between 1 and 2048 dynamically. You can use the '&' and '&&' symbols to give several circuit groups at the same time.

etpcm

ETPCM = the address of the PCM circuit is to be changed

circuit(s)

CRCT = the circuit whose state is to be changed

You can use the '&', '&&', and '&&-' symbols to give several circuits at the same time.

bit based circuit(s)

BCRCT = the bit based circuit whose state is to be changed

This parameter is used only in ETSI environment.

You can use the '&', '&&', and '&&-' symbols to modify several circuits at the same time.

The format is PCM-TSL-SUBTSL: (1–127) – (0–31)– (0–7).

Page 9: Dn 00260704

DN00260704 9

CI - Internal Routing States CIM MODIFY INTERNAL CIRCUIT OR CIRCUITGROUP STATE

Id:0900d805806fcffcConfidential

circuit group state

This parameter specifies the new state of the circuit group according to the main state.

The possible values are the following:

BA BARRED

WO WORKING

TE TEST

circuit(s) state

This parameter identifies the new state of the circuit according to the main state.

The possible values are the following:

BA BARRED

WO WORKING

Examples 1. Change the states of circuit groups TEST and TEST2.

CIM:NCGR=TEST&TEST2:BA;

2. Change the states of circuit groups 5 and 17.

CIM:CGR=5&17:WO;

3. Change the states of circuit groups 5 – 32.

CIM:CGR=5&&32:WO;

4. Change the states of all timeslots of PCM circuits 3 and 15 to normal (WO-EX).

CIM:CRCT=3-0&&-31&15-0&&-31:WO;

5. Change the states of several timeslots of circuits 72 – 1 to normal (WO-EX). This is applicable only to ETSI.

CIM:BCRCT=72–1–3&&–6:WO;

6. Change the states of several timeslots of ETPCM to normal (WO-EX).

CIM:ETPCM=64,CRCT=1-3&&-6:WO;

Execution printouts The execution printout of example 1 is the following:

INTERNAL CIRCUIT GROUP(S) STATE(S) MODIFIEDNCGR CGR OLD STATE NEW STATE

TEST 17 WO-EX BA-USTEST2 25 WO-EX BA-US

COMMAND EXECUTED

The execution printout of example 2 is the following:

INTERNAL CIRCUIT GROUP(S) STATE(S) MODIFIEDCGR NCGR OLD STATE NEW STATE

5 CGR01 BA-US WO-EX 17 TEST BA-US WO-EX

COMMAND EXECUTED

The execution printout of example 3 is the following:

Page 10: Dn 00260704

10 DN00260704

CI - Internal Routing States

Id:0900d805806fcffcConfidential

CIM MODIFY INTERNAL CIRCUIT OR CIRCUIT GROUP STATE

INTERNAL CIRCUIT GROUP(S) STATE(S) MODIFIEDCGR NCGR OLD STATE NEW STATE

5 CGR01 BA-US WO-EX 12 CGR03 BA-US WO-EX 17 TEST BA-US WO-EX 32 TEST2 BA-US WO-EX

COMMAND EXECUTED

The execution printout of example 4 is the following:

INTERNAL CIRCUIT(S) STATE(S) MODIFIED CRCT OLD STATE NEW STATE

3-0 BA-US BA-US 3-1 WO-EX BA-US . . . . . . 3-31 BA-US BA-US 15-0 WO-EX BA-US 15-1 WO-EX BA-US . . . . . . 15-31 WO-EX BA-US

COMMAND EXECUTED

The execution printout of example 5 is the following. (It is applicable only to ETSI.)

INTERNAL CIRCUIT(S) STATE(S) MODIFIED BCRCT OLD STATE NEW STATE 72– 1–3 BA-US WO-EX 72– 1–4 BA-US WO-EX 72– 1–5 BA-US WO-EX 72– 1–6 BA-US WO-EX

COMMAND EXECUTED

The execution printout of example 6 is the following.

INTERNAL CIRCUIT(S) STATE(S) MODIFIED ETPCM-TCPCM-TSL OLD STATE NEW STATE 64– 1–3 BA-US WO-EX 64– 1–4 BA-US WO-EX 64– 1–5 BA-US WO-EX 64– 1–6 BA-US WO-EX

COMMAND EXECUTED

Semantic error messages

/*** CIRCUIT GROUP NONEXISTENT ***//*** NCGR = XXXXX ***/

The circuit group is not found.

/*** CIRCUIT GROUP NOT INTERNAL ***//*** CGR = XXXXX ***/

Page 11: Dn 00260704

DN00260704 11

CI - Internal Routing States CIM MODIFY INTERNAL CIRCUIT OR CIRCUITGROUP STATE

Id:0900d805806fcffcConfidential

The circuit group is not an internal one.

/*** DX ERROR: 43053 ***//*** PCM NOT EQUIPPED ***//*** PCM = XXXXX TSL = XX ***/

The circuit does not belong to any circuit group.

The system may also output a general MML semantic error message.

Execution error messages

If an execution error occurs, the upper-level error text is either

/*** MODIFICATION NOT POSSIBLE ***/

or

/*** MODIFICATION ABORTED ***/

and below is displayed a general printout of the MML commands, specifying the error.

In addition, the following error messages may be output:

/*** MODIFICATION NOT POSSIBLE ***//*** NO UPDATED UNITS ***/

No units have been updated.

/*** MODIFICATION NOT POSSIBLE ***/

or

/*** MODIFICATION ABORTED ***/

Not all the file updates required by the commands have succeeded in all the required units.

The names of the units in which the update succeeded are output below this printout. For example, the output may be as follows:

/*** UPDATED UNITS ***/ CM-0 CM-1 M-0

Page 12: Dn 00260704

12 DN00260704

CI - Internal Routing States

Id:0900d805806fcffeConfidential

CII INTERROGATE INTERNAL CIRCUIT OR CIRCUIT GROUP STATE

CII INTERROGATE INTERNAL CIRCUIT OR CIRCUIT GROUP STATE

Function Use this command to interrogate the states of one or several circuit groups or circuits.

Parameters circuit group name, circuit group number, circuit(s), bit based circuit(s) (European Tele-communications Standards Institute (ETSI)): circuit group state, circuit(s) state;

Syntax CII: ( NCGR = <circuit group name>... |

CGR = <circuit group number>... |

ETPCM = <et-pcm>|

CRCT = <circuit(s)>... |

BCRCT = <bit based circuit(s)>... ) :

If NCGR or CGR given:

[ WO | BA | TE | <all> def ];

If CRCT given:

[ WO | BA | <all> def ];

Parameter explana-tions

circuit group name

NCGR = the name of the circuit group whose state is to be inquired

You can use the '&' symbol to give several circuit groups at the same time.

circuit group number

CGR = the number of the circuit group whose state is to be inquired

The possible values range between 1 and 2048 dynamically. You can use the '&' and '&&' symbols to give several circuit groups at the same time.

etpcm

ETPCM = the address of the PCM circuit.

circuit(s)

CRCT = the circuit whose state is to be inquired

You can use the '&', '&&', and '&&-' symbols to inquire several circuits at the same time.

bit based circuit(s)

BCRCT = the bit based circuit whose state is to be inquired

This parameter is used only in ETSI environment.

You can use the '&', '&&', and '&&-' symbols to inquire several circuits at the same time.

The format is PCM-TSL-SUBTSL: (1–127) – (0–31) – (0–7).

Page 13: Dn 00260704

DN00260704 13

CI - Internal Routing States CII INTERROGATE INTERNAL CIRCUIT OR CIRCUITGROUP STATE

Id:0900d805806fcffeConfidential

circuit group state

This parameter identifies the state of the circuit group according to the main state.

The possible values are the following:

BA BARRED

WO WORKING

TE TEST

The default value is <all>, which shows all the states of the circuit groups.

circuit(s) state

This parameter identifies the state of the circuit according to the main state.

The possible values are the following:

BA BARRED

WO WORKING

The default value is <all>, which shows all the states of the circuits.

Examples 1. Output the states of circuit groups TEST and TEST2 according to the name of the circuit group.

CII:NCGR=TEST&TEST2;

2. Output the states of circuit groups 17 and 26 according to the number of the circuit group.

CII:CGR=17&26;

3. Output all circuit groups 5 to 17 in the WO-EX state.

CII:CGR=5&&17:WO;

4. Output timeslot 12 of circuits 1, 3, 4, and 9.

CII:CRCT=1-12&3-12&4–12&9–12;

5. Output sub-timeslots 72-1-0, 73-8-3, 74-31-7, and 75-20-0. This is applicable only to ETSI.

CII:BCRCT=72-1-0&73-8-3&74-31-7&75-20-0;

6. Output ETPCM circuits.

CII:ETPCM=64,CRCT=1-3&&-6;

Execution printouts The execution printout of example 1 is the following:

INTERNAL CIRCUIT GROUP(S) STATE(S)

NCGR CGR STATE

TEST 17 BA-US

NUMBER OF CIRCUITS: 0

TEST2 25 WO-EX

NUMBER OF CIRCUITS: 62

Page 14: Dn 00260704

14 DN00260704

CI - Internal Routing States

Id:0900d805806fcffeConfidential

CII INTERROGATE INTERNAL CIRCUIT OR CIRCUIT GROUP STATE

STATE CONN COND COUNT BA-US IDLE - 62

COMMAND EXECUTED

The execution printout of example 2 is the following:

INTERNAL CIRCUIT GROUP(S) STATE(S)

CGR NCGR STATE

17 TEST BA-US

NUMBER OF CIRCUITS: 0

26 TEST3 WO-EX

NUMBER OF CIRCUITS: 62

STATE CONN COND COUNT WO-EX BUSY - 12 WO-EX IDLE - 7 BA-SY IDLE FAULTY 31 BA-US IDLE - 18

COMMAND EXECUTED

The execution printout of example 3 is the following:

INTERNAL CIRCUIT GROUP(S) STATE(S)

CGR NCGR STATE

5 CGR05 WO-EX

NUMBER OF CIRCUITS: 0

6 TEST2 BA-US

NUMBER OF CIRCUITS: 31

STATE CONN COND COUNT WO—EX IDLE - 31

16 CGR16 WO-EX

NUMBER OF CIRCUITS: 93

STATE CONN COND COUNT WO-EX IDLE - 21

Page 15: Dn 00260704

DN00260704 15

CI - Internal Routing States CII INTERROGATE INTERNAL CIRCUIT OR CIRCUITGROUP STATE

Id:0900d805806fcffeConfidential

BA-SY IDLE - 31 BA-SY IDLE FAULTY 31 BA-US IDLE - 10

17 TES12 BA-US

NUMBER OF CIRCUITS: 0

COMMAND EXECUTED

The execution printout of example 4 is the following:

INTERNAL CIRCUIT STATE(S)

CRCT STATE CONN COND SYS_ST

1-12 BA-SY IDLE FAULTY PS 3-12 BA-US IDLE - ET 4-12 BA-SY IDLE - ET 9-12 WO-EX BUSY - -

COMMAND EXECUTED

The execution printout of example 5 is the following. (It is applicable only to ETSI.)

INTERNAL CIRCUIT STATE(S)

BCRCT STATE CONN COND SYS_ST

72- 1-0 BA-SY IDLE - ET 73- 8-3 BA-SY IDLE FAULTY PS 74-31-7 WO-EX IDLE - - 75-20-0 BA-US IDLE - -

COMMAND EXECUTED

The execution printout of example 6 is the following.

INTERNAL CIRCUIT STATE(S)

ETPCM-TCPCM-TSL STATE CONN COND SYS_ST

64- 1-3 WO-EX BUSY - - 64- 1-4 WO-EX BUSY - - 64- 1-5 WO-EX BUSY - - 64- 1-6 WO-EX BUSY - -

Page 16: Dn 00260704

16 DN00260704

CI - Internal Routing States

Id:0900d805806fcffeConfidential

CII INTERROGATE INTERNAL CIRCUIT OR CIRCUIT GROUP STATE

COMMAND EXECUTED

Semantic error messages

If an error occurs, the system outputs a general MML semantic error message.

Execution error messages

/*** NONEXISTENT CIRCUIT GROUP ***/

The circuit group is not found.

/*** CIRCUIT GROUP NOT INTERNAL ***/

The circuit group is not an internal one.

/*** DX ERROR: 43053 ***//*** PCM NOT EQUIPPED ***/

The circuit does not belong to any circuit group.

The system may also output a general MML execution error message.

Page 17: Dn 00260704

DN00260704 17

CI - Internal Routing States CIC MODIFY INTERNAL ROUTE STATE

Id:0900d805802f5816Confidential

CIC MODIFY INTERNAL ROUTE STATEFunction With this command you can change the states of one or several internal outgoing routes.

Parameters route number: route state;

Syntax CIC: ROU = <route number> ... :

( WO | BA );

Parameter explana-tions

route number

ROU = the number of the outgoing route whose state is to be changed

The value range is 1 – 4098 dynamically and you can use the symbols & and && to give several routes at the same time.

route state

The new state of the outgoing route according to the main state:

WO WORKING

BA BARRED

In the Mobile Switching Center (MSC) and in the DX HLR (HLR), only the group switch (GSW) is used. In case of SSW, you must also give the number of the subscriber stage which the command concerns.

Examples 1. Change the states of the outgoing routes 25 and 32 to barred.

CIC:ROU=25&32:BA;

2. Change the states of the outgoing routes 3 - 6 to working.

CIC:ROU=3&&6:WO;

Execution printouts Here is the execution printout of example 1:

INTERNAL ROUTE STATE(S) MODIFIED

ROU OLD STATE NEW STATE

25 WO-EX BA-US 32 WO-EX BA-US

COMMAND EXECUTED

Here is the execution printout of example 2:

INTERNAL ROUTE STATE(S) MODIFIED

ROU OLD STATE NEW STATE

3 BA-US BA-US 4 WO-EX BA-US 5 WO-EX BA-US 6 WO-EX BA-US

COMMAND EXECUTED

Page 18: Dn 00260704

18 DN00260704

CI - Internal Routing States

Id:0900d805802f5816Confidential

CIC MODIFY INTERNAL ROUTE STATE

Semantic error messages

/*** ROUTE NONEXISTENT ***//*** ROU = XXXXX ***/

An outgoing route with the given number is not found.

/*** CIRCUIT GROUP NONEXISTENT ***//*** NCGR = XXXXX ***/

The circuit group belonging to the outgoing route is not found.

/*** ROUTE NOT INTERNAL OPTIONAL ***//*** ROU = XXXXX ***/

The outgoing route is not an internal one.

The system may also output a general MML semantic error message.

Execution error messages

If an execution error occurs, the upper-level error text is either

/*** MODIFICATION NOT POSSIBLE ***/

or

/*** MODIFICATION ABORTED ***/

and below is displayed a general printout of the MML commands, specifying the error.

In addition, the following error messages may be output:

/*** MODIFICATION NOT POSSIBLE ***//*** NO UPDATED UNITS ***/

The printout indicates that no units have been updated.

/*** MODIFICATION NOT POSSIBLE ***/

or

/*** MODIFICATION ABORTED ***/

The printout indicates that all the file updates required by the command have not suc-ceeded in all the required units.

The names of the units in which the update succeeded are output below this printout. For example, the output may be as follows:

/*** UPDATED UNITS ***/ CM-0

Page 19: Dn 00260704

DN00260704 19

CI - Internal Routing States CIL INTERROGATE INTERNAL ROUTE STATE

Id:0900d8058042352aConfidential

CIL INTERROGATE INTERNAL ROUTE STATE

Function Use this command to inquire the states of one or several internal outgoing routes.

Parameters route number: route state;

Syntax CIL: ROU = <route number ... :

[ WO | BA | <all> def ];

Parameter explana-tions

route number

ROU = the number of the outgoing route whose state is to be inquired

The possible values range between 1 and 4098 dynamically, and you can use the '&' and '&&' symbols to give several routes at the same time.

route state

This parameter defines the state of the outgoing route according to the main state.

The possible values are the following:

WO WORKING

BA BARRED

The default value is <all>, which shows all the states of the routes.

Examples 1. Output the states of the outgoing routes 25 and 32.

CIL:ROU=25&32:,;

2. Output the states of the outgoing routes 11 - 14.

CIL:ROU=11&&14:,;

Execution printouts The execution printout of example 1 is the following:

INTERNAL ROUTE STATE(S) ROU STATE NCGR STATE

25 BA-US KOE01 TE-US CGR02 BA-US 32 BA-US CGR07 BA-US CGR12 WO-EX TEST0 TE-US

COMMAND EXECUTED

The execution printout of example 2 is the following:

INTERNAL ROUTE STATE(S) ROU STATE NCGR STATE

11 BA-US KOE01 WO-EX CGR02 BA-US 17 BA-US CGR07 BA-US CGR12 WO-EX

Page 20: Dn 00260704

20 DN00260704

CI - Internal Routing States

Id:0900d8058042352aConfidential

CIL INTERROGATE INTERNAL ROUTE STATE

TEST0 BA-US 25 BA-US CGR13 BA-US CGR14 WO-EX TEST2 BA-US 32 BA-US CGR16 BA-US CGR17 WO-EX TEST3 BA-US

COMMAND EXECUTED

Semantic error messages

If an error occurs, the system outputs a general MML semantic error message.

Execution error messages

/*** ROUTE NONEXISTENT ***/

The outgoing route is not found.

/*** ROUTE NOT INTERNAL OPTIONAL ***/

The outgoing route is not an internal optional route.

The system may also output a general MML execution error message.