DataOn Storage DNS-1400 SAS JBOD Storage System
System Highlights
4U 24 hot-swappable drive bays with
key-lock front bezel
Dual active-to-active, fail-over SAS
JBOD I/O Modules
Two 3Gb/s SAS Ports on each SAS I/O
Module, one-in & one-out
24 x dual ported (w/interposer) for SAS
or SATA II hard disks
760W Redundant hot-swappable power
& cooling modules
GUI based SES Management Tool to
monitor the system
Online Firmware Upgrade ensures
systems high availability
By daisy-chaining JBODs, supports up to
96 hard disk drives
Performance, Capacity, Scalability and Reliability
Product Overview
The DataON Storage DNS-1400 SAS JBOD is a high-density, high-reli-
ability and cost-effective SAS host to SAS/SATA-II disk direct attached
primary or near-line storage solution.
With DataON Storage DNS-1400, you can customize the storage system
foryourneeds.Congureitmeetthehighreliability,high-performancewith SAS disk drive or low-cost high-capacity requirements with SATA-II
disk drive or to create tiered storage solutions by mixing both SAS and
SATA-II disk drives in the same system.
The DataON Storage DNS-1400 SAS JBOD offers the high-performance
and continuous availability demanded by todays business applications
and provides customers with choices in performance, capacity and reli-
ability.
Density and Scalability
Each DNS-1400 SASS JBOD supports up to 24 disk drives in a 4U
enclosure. It provides up to 18.0TB of SATA storage capacity for non-
critical data or up to 7.2TB of high-performance 300GB 15K RPM 3.5
SAS disk drive for primary mission-critical data storage.
The DNS-1400 SAS JBOD can be scaled to a total of 96 spindles (or four
enclosures) for a total capacity of 72.0TB with SATA-II disk drive or
28.8TB with high-performance SAS disk drive.
Redundancy & Reliability
Hot-Swappable disk drives and redundant, hot-swappable power and
cooling modules that ensure the highest level of system availability and
maximum possible uptime is achieved through dual active-active Serial
Attached SCSI I/O Module controllers that provide failover/failback
operation.
-
8/3/2019 dns-1400
2/2
DataOn Storage DNS-1400 SAS JBOD Storage System
950 Fee Ana Street
Placentia, CA 92870
(714) 993-0300
www.areasys.com
Host Interface One SAS I/O Module (SIM) supports two SAS 3G wide ports
Supports SAS Expander
Dual wide port capacity supporting up to 2,400MB/s
Hard Disk Interface 24 x dual ported SAS (3Gb/s) or SATA II hard disks with AA MUX (1.5Gb/s or3.0Gb/s)
Up to 24 hard disks, provide 7.2TB with SAS Disks (300GB) or 18TB with SATA II
disks (750GB)
Max. 96 SAS/SATA II hard disks by Daisy Chaining 4 x DNS-1400 Systems
SAS I/O Module (SIM) Single or Dual SAS I/O Modules
Supports Redundant path fail-over function with dual SAS I/O Modules that pro-
vides data redundancy
For SATA hard disks fail-over function, Interposer cards are required
Redundant & Hot-Swappable Two JBOD SAS I/O Modules, Active-Active Fail-over
Two Advanced DELTA 760-Watt 1+1 Redundant hot-swappable Power Supply and
Cooling Modules
Up to 24 SAS/SATA II hard disks
Monitoring SES Manager is easy-to-use GUI-based tool allows administrators to monitor the
status and health of the system
LED indicators for JBOD Control Modules, Power & Cooling Modules, Hard disks
Status
Maximum SAS Cable Length Up to 3 Meters
Dimensions & Weight Rack Mount: 4U w/24 Hard Disk Dive Bays
Enclosure: 6.875 (H) x 17.5 (W) x 23 (D)
Net Weight: 67lbs w/2 x SAS I/O Modules (no packing)
Actual Weight: 116lbs w/Double shipping cartons & 24 hard disks
AC Power Input Voltage: Auto Ranging, 100-240VAC
Input Frequency: 50-60MHz
Input Current: 100-240 VAC @ 11.2A
AC Inlets: Dual IEC power connectors
Output Power: 760-Watt
Operating Environment Operating Temperature: 0 to 40 C
Operating Humidity: 5% to 95%
Altitude: -50 to 10,000 feet
Shock: 31G @ 2.6 ms, 1/2 sine wave pulse
Vibration: 0.25G @ 3Hz to 200Hz
Electromagnetic Emissions Stan-
dards
FCC Class A Part 15, VCCI - for Japan, CCC - for China
CE-SpecicallyrequirementsineffectJuly1st,2001
Safety Standards UL/cUL: for U.S. and Canada / UL60950-1TUV: for Germany / EN60950-1
CB(b TUV): IEC60950-1
RoHS Compliance
TechnicalSpecication