Protect
circuit protectionDomae circuit breakersC curvesIEC 60898: 4500 A
FunctionThe circuit breakers combine the following functions:
protection of circuits against short-circuit currents
protection of circuits against overload currents
Tripping curvesC curveCables feeding conventional loads.
Power circuit:
ratings: 6 to 63 A set at 30°C
tripping curve: the magnetic trip units operate between 5 and 10 In
Technical according to IEC 60898Power circuit:
voltage rating (Ue): 440 V AC
breaking capacity:
according to IEC 60898, Icn ultimate breaking capacity (O-CO cycle):
Rating (A) Type Voltage (V) Breaking capacity Icn (A)
6...63 1P 230/400 4500
2P, 3P 400 4500
limitation class (IEC 60898): 3.
General technical dataFast closing: allows the high inrush currents of some loads to be better held.
Isolation with positive break indication: opening is indicated by a green strip on the
device operating handle. This indicator shows opening contacts of all the poles.
Number of cycles (O-C): 20,000.
Environment:
tropicalization: treatment 2 (relative humidity: 95% at 55°C) according to
IEC 60068-1Connection: tunnel terminals for the following cables:
16mm2 flexible or 25mm 2 rigid up to 25 A ratings
25mm2
flexible or 35mm2
rigid for 32 to 63 A ratings
-
Catalogue numbersType Rating (A) Width in mod. Catalogue number
of 9mm C curve1P
6 2 DOM1134010 2 DOM1134116 2 DOM1134220 2 DOM1134325 2 DOM1134432 2 DOM1134540 2 DOM1134650 2 DOM1133563 2 DOM11336
2P6 4 DOM11230
10 4 DOM1123116 4 DOM1123220 4 DOM1123325 4 DOM1123432 4 DOM1123540 4 DOM1123650 4 DOM1123763 4 DOM11238
3P6 6 DOM1134710 6 DOM1134816 6 DOM1134920 6 DOM1135025 6 DOM1135132 6 DOM1135240 6 DOM1135350 6 DOM1133763 6 DOM11338
1
-
8/19/2019 Domae Brochure 2014 (the Right Solution for Distribution Boards)
3/34
Protect
circuit protectionDomae circuit breakersB and C curves
IEC 60898: 6000 A
FunctionThe circuit-breakers combine the following functions:
protection of circuits against short-circuit currents
protection of circuits against overload currents
Tripping curvesB curveWhen the short-circuit currents are weak (generators, long cables).
Power circuit:
ratings: 6 to 63 A set at 30°C
tripping curve: the magnetic trip units operate between 3 and 5 In
C curveCables feeding conventional loads.
Power circuit:
ratings: 6 to 63 A set at 30°C
tripping curve: the magnetic trip units operate between 5 and 10 In
Technical data according to IEC 60898Power circuit:voltage rating (Ue): 440 V AC
breaking capacity:
according to IEC 60898, Icn ultimate breaking capacity (O-CO cycle):
Rating (A) Type Voltage (V) Breaking capacity Icn (A)
6...63 1P 230/400 6000
2P, 3P 400 6000
limitation class (IEC 60898): 3.
General technical dataFast closing: allows the high inrush currents of some loads to be better held.
Isolation with positive break indication: opening is indicated by a green strip on the
device operating handle. This indicator shows opening contacts of all the poles.
Number of cycles (O-C): 20,000.
Environment:
tropicalization: treatment 2 (relative humidity: 95% at 55°C) according to
IEC 60068-1Connection: tunnel terminals for the following cables:
16mm2 flexible or 25mm 2 rigid up to 25 A ratings
25mm2 flexible or 35mm 2 rigid for 32 to 63 A ratings
-
Catalogue numbersType Rating (A) Width in mod. Catalogue number
of 9mm B curve C curve1P
6 2 DOM11362 DOM1137510 2 DOM11363 DOM1137616 2 DOM11364 DOM1137720 2 DOM11365 DOM1137825 2 DOM11366 DOM1137932 2 DOM11367 DOM1138040 2 DOM11414 DOM11381
50 2 DOM11607 DOM1159863 2 DOM11608 DOM11599
2P6 4 DOM11417 DOM11384
10 4 DOM11418 DOM1138516 4 DOM11419 DOM1138620 4 DOM11420 DOM1138725 4 DOM11421 DOM1138832 4 DOM11368 DOM1138940 4 DOM11369 DOM1139050 4 DOM11609 DOM1160063 4 DOM17321 DOM11601
3P6 6 DOM11426 DOM1139310 6 DOM11427 DOM1139416 6 DOM11428 DOM1139520 6 DOM11429 DOM1139625 6 DOM11430 DOM11397
32 6 DOM11431 DOM1139840 6 DOM11432 DOM1139950 6 DOM11610 DOM1160263 6 DOM11611 DOM11603
2
-
8/19/2019 Domae Brochure 2014 (the Right Solution for Distribution Boards)
4/34
Protect
earth leakage protectionDomae circuit breakersResidual Current Circuit Breaker
FunctionResidual current circuit-breakers ensure:
the control and isolation of electrical circuits
the protection of persons against direct and indirect contacts
AC class Residual Current Circuit Breaker (RCCB)Type Voltage Rating Sensitivity Catalogue
50 Hz (A) (mA) number (V)
2P240V 40 30 DOM16793
100 DOM16818300 DOM16795
63 30 DOM16791100 DOM16819300 DOM16798
4P415V 40 30 DOM11029
100 DOM16814300 DOM11030
63 30 DOM16794100 DOM16815300 DOM16796
the protection of installation against insulation faults
AC classTripping is ensured for sinusoidal, alternating currents, whether they be quickly
applied or slowly increase.
Technical data Voltage rating:
- 240...415 V AC
Frequency rating;
- AC class : 50 Hz
Catalogue numbers
3
-
8/19/2019 Domae Brochure 2014 (the Right Solution for Distribution Boards)
5/34
4
__________________________________________________________________________________________________________________________________________________________________________
Rating (In) Curve C Curve C Curve C Curve C Curve C__________________________________________________________________________________________________________________________________________________________________________ 6 A A9F84106 A9F84606 A9F84206 A9F84306 A9F84406__________________________________________________________________________________________________________________________________________________________________________ 10 A A9F84110 A9F84610 A9F84210 A9F84310 A9F84410__________________________________________________________________________________________________________________________________________________________________________ 13 A A9F84113 A9F84613 A9F84213 A9F84313 A9F84413__________________________________________________________________________________________________________________________________________________________________________ 16 A A9F84116 A9F84616 A9F84216 A9F84316 A9F84416__________________________________________________________________________________________________________________________________________________________________________ 20 A A9F84120 A9F84620 A9F84220 A9F84320 A9F84420__________________________________________________________________________________________________________________________________________________________________________ 25 A A9F84125 A9F84625 A9F84225 A9F84325 A9F84425__________________________________________________________________________________________________________________________________________________________________________ 32 A A9F84132 A9F84632 A9F84232 A9F84332 A9F84432__________________________________________________________________________________________________________________________________________________________________________ 40A A9F84140 A9F84640 A9F84240 A9F84340 A9F84440__________________________________________________________________________________________________________________________________________________________________________ 50A A9F84150 A9F84650 A9F84250 A9F84350 A9F84450__________________________________________________________________________________________________________________________________________________________________________ 63A A9F84163 A9F84663 A9F84263 A9F84363 A9F84463__________________________________________________________________________________________________________________________________________________________________________ Width in 9-mm modules 2 4 4 6 8__________________________________________________________________________________________________________________________________________________________________________
iC60H circuit breakers(curve C)
D B 1 1
6 6 1 9
Country approval pictograms
Protection
Circuit protection
b iC60H circuit breakers are multi-standard circuit breakers which combine the
following functions:
v circuit protection against short-circuit currents, v circuit protection against overload currents,
v suitable for industrial isolation according to IEC/EN 60947-2, standard.
v fault tripping indication by a red mechanical indicator in circuit breaker front face.
IEC/EN 60947-2
IEC/EN 60898-1
Alternating current (AC) 50/60 Hz
Breaking capacity (Icu) according to IEC/EN 60947-2 Service
breaking
capacity
(Ics)
Voltage (Ue)
Ph/Ph (2P, 3P, 4P) 12 to 133 V 220 to 240 V 380 to 415 V 440 V
Ph/N (1P, 1P+N) 12 to 60 V 100 to 133 V 220 to 240 V -
Rating (In) 0.5 to 4 A 70 kA 70 kA 70 kA 50 kA 100% of Icu
6 to 63A 42 kA 30 kA 15 kA 10 kA 50% of Icu
Breaking capacity (Icn) according to IEC/EN 60898-1
Voltage (Ue)
Ph/Ph 400 V
Ph/N 230 V
Rating (In) 0.5 to 63 A 10000 A
Direct current (DC)
Breaking capacity (Icu) according to IEC/EN 60947-2 Service
breaking
capacity
(Ics)
Voltage (Ue)
Between +/- 12 to 60 V y 72 V y 125 V y 180 V y 250 V
Number of poles 1P 2P 3P 4PRating (In) 1 to 63 A 20 kA 15 kA 15 kA 15 kA 15 kA 100% of Icu
P B 1 0 4 4 4 1 - 4 0
P B 1 0 4 4 5 1 - 4 0
Catalogue numbers iC60H circuit breaker
Type 1P 1P+N 2P 3P 4P
1
2 N
N 1
2
1
2
3
4
1
2
3
4
5
6
1
2
3
4
5
6
7
8
-
8/19/2019 Domae Brochure 2014 (the Right Solution for Distribution Boards)
6/34
5
b Increased product service life thanks to:
v overvoltage resistance by high level of industrial performances conception(pollution degree, rated impulse withstand voltage and insulation voltage),
v high performance limitation (see limitation curves),
v fast closing independent of the speed of actuation of the toggle.
b Remote indication, open/closed/tripped, by optional auxiliary contacts. b Top or bottom electrical feeding.
Visi-trip windowb Fault tripping is indicated by a redmechanical indicator on the front face
b Double clip for
dismounting with comb
busbar in place
Positive contact indication b Suitable for industrial isolation according to
IEC/EN 60947-2 standard
b The presence of the green strip guarantees
physical opening of the contacts and allowsoperations to be performed on the downstream
circuit in complete safety
b Insulated terminals IP20
iC60H circuit breakers(curve C) (cont.)
Protection
Circuit protection
b Large circuit
labelling area
P B 1 0
4 4 3 5 - 4 0
-
8/19/2019 Domae Brochure 2014 (the Right Solution for Distribution Boards)
7/34
6
Rated discharge
current (Imax) /
Nominal discharge
current (In)
Type of protection Network
Incoming Secondary(type 2 or 3)
1P+N 3P+N 1P 2P 3P 4P
65 kA / 20 kA
iPF65 A9L15683
A9L15684
A9L15584
A9L15581
A9L15685
A9L15586
A9L15585
40 kA / 15 kA
High risk level iPF40 A9L15686
A9L15687
A9L15587
A9L15582
A9L15690
A9L15688
A9L15590
A9L15588
20 kA / 5 kA
Medium risk level iPF20 A9L15691
A9L15692
A9L15592
A9L15597
A9L15693
A9L15593
8 kA / 2.5 kA
Secondary protection:placed near the loads to beprotected when they are at adistance of more than 30mfrom the incoming surgearrester
iPF8 A9L15694
A9L15695
A9L15595
A9L15598
A9L15696
A9L15596
Each surge arrester in the range has a specic application:
b incoming protection (type 2):
v the iPF65(r) is recommended for a very high risk level (strongly exposed site)
v the iPF40(r) is recommended for a high risk level v the iPF20 is recommended for a medium risk level
b secondary protection (type 2 or 3):
v the iPF8 ensures secondary protection of loads to be protected and is placed in
cascade with the incoming surge arresters. This surge arrester is required when theloads to be protected are at a distance of more than 30m from the incoming surge
arrester.
The iPF surge arresters with “r” indication have remote transfer of the information:“surge arrester to be replaced”.
The iPF multi-pole single-piece surge arrester
range is adapted for earthing systems: TT, TN-S,
TN-C.
Type 2 surge arresters are tested with a 8/20μs
current wave.
Type 3 surge arresters are tested with a 12/50 μs
and 8/20μs combined wave.
1P+N.
3P+N.
P B 1 0 5 2 7 8 - 3 5
P B 1 0 5 2 8 0 - 3 5
Protection
Load protectioniPF surge arrestersType 2 or 3 LV surge arresters
D B 1 2 2 9 4 2
D B 1 2 2 9 4 3
Surge arrester/circuit breaker association
Type of surge arrester Associated circuit breaker
iPF65 Curve C 50 A
iPF40 Curve C 40 A
iPF20 Curve C 25 A
iPF8 Curve C 20 A
r1 r
2
-
8/19/2019 Domae Brochure 2014 (the Right Solution for Distribution Boards)
8/34
7
Protection
Load protectioniPF surge arrestersType 2 or 3 LV surge arresters (cont.)
Earthing
system
Transfer Surge
arrester
name
Width
in mod.
of 9mm
Up - (kV)
Voltage protection level
Un - (V)
Rated
voltage
network
Uc - (V)
Maximum continuous
operating voltage
CM* DM* CM* DM*
L/t N/t L/N L/t N/t L/N
iPF65
TT & TN iPF65 1P 2 y 1.5 - - 230 340 - -
TT & TN-S iPF65 1P+N 4 - y 1.5 y 1.5 - 260 340
TN-C iPF65 2P y 1.5 y 1.5 - 340 340 -
TN-C iPF65 3P 8 y 1.5 - - 230/400 340 - -
TT & TN-S b iPF65r 3P+N - y 1.5 y 1.5 - 260 340
TT & TN-S iPF65 3P+N - y 1.5 y 1.5 - 260 340
TN-C b iPF65r 4P y 1.5 y 1.5 - 340 340 -
iPF40
TT & TN iPF40 1P 2 y 1.5 - - 230 340 - -
TT & TN-S iPF40 1P+N 4 - y 1.5 y 1.5 - 260 340
TN-C iPF40 2P y 1.5 y 1.5 - 340 340 -
TN-C iPF40 3P 8 y 1.5 - - 230/400 340 - -
TT & TN-S b iPF40r 3P+N - y 1.5 y 1.5 - 260 340
TT & TN-S iPF40 3P+N - y 1.5 y 1.5 - 260 340
TN-C b iPF40r 4P y 1.5 y 1.5 - 340 340 -
TN-C iPF40 4P y 1.5 y 1.5 - 340 340 -
iPF20
TT & TN iPF20 1P 2 y 1.1 - - 230 340 - -
TT & TN-S iPF20 1P+N 4 - y 1.5 y 1.1 - 260 340
TN-C iPF20 2P y 1.1 y 1.1 - 340 340 -
TN-C iPF20 3P 8 y 1.1 - - 230/400 340 - -
TT & TN-S iPF20 3P+N - y 1.5 y 1.1 - 260 340
TN-C iPF20 4P y 1.1 y 1.1 - 340 340 -
iPF8 (1) Type 2 / Type 3
TT & TN iPF8 1P 2 y 1 / y 1.1 - - 230 340 - -
TT & TN-S iPF8 1P+N 4 - y 1.5 / y 1.2 y 1 / y 1.1 - 260 340
TN-C iPF8 2P y 1 / y 1.1 y 1 / y 1.1 - 340 340 -
TN-C iPF8 3P 8 y 1 / y 1.1 - - 230/400 340 - -
TT & TN-S iPF8 3P+N - y 1.5 / y 1.2 y 1 / y 1.1 - 260 340
TN-C iPF8 4P y 1 / y 1.1 y 1 / y 1.1 - 340 340 -
* CM : common mode (phase to earth and neutral to earth). * DM : differential mode (phase to neutral). (1) Uoc : combination waveform : 10 kV.
r1 = 1P + N : Full Mode
r2 = 3P + N : Full Mode
-
8/19/2019 Domae Brochure 2014 (the Right Solution for Distribution Boards)
9/34
8
3P+N
Cartridge
1P+N
3P
Surge arrester/circuit breaker association
Type of surge arrester Associated circuit breaker
iPRD65 Curve C 50 A
iPRD40 Curve C 40 A
iPRD20 Curve C 25 A
iPRD8 Curve C 20 A
Spare cartridges
Type Spare cartridges for Cat. no
C 65-460 iPRD65r IT A9L16682
C 65-340 iPRD65r A9L16681
C 40-460 iPRD40r IT A9L16684
C 40-340 iPRD40, iPRD40r A9L16685
C 20-460 iPRD20r IT A9L16686C 20-340 iPRD20, iPRD20r A9L16687
C 8-460 iPRD8r IT A9L16688
C 8-340 iPRD8, iPRD8r A9L16689
C neutral All products A9L16691
Protection
Load protection
iPRD withdrawable
surge arresters allow
quick replacement of
damaged cartridges.
iPRD surge arrestersType 2 or 3 LV withdrawable surgearresters
r1 r
2
D
B 1 2 2 9 4 2
D
B 1 2 2 9 4 3
P B 1 0 5 2 7 6 - 3 5
P B 1 0 5 2 7 2 - 3 5
P B 1 0 5 2 7 4 - 3 5
P B 1 0 5 2 7 5 - 3 5
Rated discharge
current (Imax) /
Nominal dischargecurrent (In)
Type of
protection
Network
Incoming Secondary 1P+N 3P+N 1P 2P 3P 4P
65 kA / 20 kA
Very high risk level(strongly exposed site)
iPRD65 A9L16555
A9L16556
A9L16557
A9L16442
A9L16558
A9L16443
A9L16559
A9L16659
40 kA / 15 kA
High risk level iPRD40 A9L16561
A9L16566
A9L16562
A9L16567
A9L16444
A9L16667
A9L16445
A9L16568
A9L16563
A9L16564
A9L16569
A9L16597
A9L16664
A9L16669
20 kA / 5 kA
Medium risk level iPRD20 A9L16571
A9L16672
A9L16572
A9L16446
A9L16447
A9L16573
A9L16674
A9L16574
A9L16599
A9L16673
8 kA / 2.5 kA
Secondary protection:placed near the loads to beprotected when they are at a
distance of more than 30mfrom the incoming surgearrester
iPRD8 A9L16576
A9L16677
A9L16577
A9L16448
A9L16449
A9L16578
A9L16679
A9L16579
A9L16678
A9L16680
r1 r
2
-
8/19/2019 Domae Brochure 2014 (the Right Solution for Distribution Boards)
10/34
9
Earthing
system
Transfer Surge
arrester
name
Width
in mod.
of 9mm
Up - (kV)
Voltage protection level
Un - (V)
Rated
voltagenetwork
Uc - (V)
Maximum continuous
operating voltage
CM* DM* CM* DM*
L/t N/t L/N L/t N/t L/N
iPRD65
IT b iPRD65r 1P IT 2 y 2 - - 230 460 - -
TT & TN b iPRD65r 1P y 1.5 - - 340 - -
TT & TN-S b iPRD65r 1P+N 4 - y 1.5 y 1.5 - 260 340
TN-C b iPRD65r 2P y 1.5 y 1.5 - 340 340 -
IT b iPRD65r 3P IT 6 y 2 - - 230/400 460 - -
TN-C b iPRD65r 3P y 1.5 - - 340 - -
TT & TN-S b iPRD65r 3P+N 8 - y 1.5 y 1.5 - 260 340
TN-C b iPRD65r 4P y 1.5 y 1.5 - 340 340 -
iPRD40
TT & TN b iPRD40r 1P 2 y 1.4 - - 230 340 - -
TT & TN iPRD40 1P y 1.4 - - 340 - -
TT & TN-S b iPRD40r 1P+N 4 - y 1.4 y 1.4 - 260 340
TT & TN-S iPRD40 1P+N - y 1.4 y 1.4 - 260 340
TN-C b iPRD40r 2P y 1.4 y 1.4 - 340 340 -
TN-C iPRD40 2P y 1.4 y 1.4 - 340 340 -
TN-C b iPRD40r 3P 6 y 1.4 - - 230/400 340 - -
TN-C iPRD40 3P y 1.4 - - 340 - -
IT b iPRD40r 3P IT y 2 - - 460 - -
TT & TN-S b iPRD40r 3P+N 8 - y 1.4 y 1.4 - 260 340
TT & TN-S iPRD40 3P+N - y 1.4 y 1.4 - 260 340
IT b iPRD40r 4P IT y 2 y 2 - 460 460 -
TN-C b iPRD40r 4P y 1.4 y 1.4 - 340 340 -
TN-C iPRD40 4P y 1.4 y 1.4 - 340 340 -
iPRD20
TT & TN iPRD20 1P 2 y 1.1 - - 230 340 - -
TT & TN-S b iPRD20r 1P+N 4 - y 1.4 y 1.1 - 260 340
TT & TN-S iPRD20 1P+N - y 1.4 y 1.1 - 260 340
TN-C iPRD20 2P y 1.1 y 1.1 - 340 340 -
TN-C iPRD20 3P 6 y 1.1 - - 230/400 340 - -
IT b iPRD20r 3P IT y 1.6 - - 460 - -
TT & TN-S b iPRD20r 3P+N 8 - y 1.4 y 1.1 - 260 340
TT & TN-S iPRD20 3P+N - y 1.4 y 1.1 - 260 340
IT b iPRD20r 4P IT y 1.6 y 1.6 - 460 460 -
TN-C iPRD20 4P y 1.1 y 1.1 - 340 340 -
iPRD8 (1) Type 2 / Type 3
TT & TN iPRD8 1P 2 y 1 / y 1 - - 230 340 - -
TT & TN-S b iPRD8r 1P+N 4 - y 1.4 / y 1 y 1 / y 1.1 - 260 340
TT & TN-S iPRD8 1P+N - y 1.4 / y 1 y 1 / y 1.1 - 260 340
TN-C iPRD8 2P y 1 / y 1 y 1 / y 1 - 340 340 -
TN-C iPRD8 3P 6 y 1 / y 1 - - 230/400 340 - -
IT b iPRD8r 3P IT y 1.4 / y 1.6 - - 460 - -
TT & TN-S b iPRD8r 3P+N 8 - y 1.4 / y 1 y 1 / y 1.1 - 260 340
TT & TN-S iPRD8 3P+N - y 1.4 / y 1 y 1 / y 1.1 - 260 340
IT b iPRD8r 4P IT y 1.4 / y 1.6 y 1.4 / y 1.6 - 460 460 -
TN-C iPRD8 4P y 1 / y 1 y 1 / y 1 - 340 340 -
* CM : common mode (phase to earth and neutral to earth). * DM : differential mode (phase to neutral). (1) Uoc : combination waveform : 10 kV.
Protection
Load protectioniPRD surge arrestersType 2 or 3 LV withdrawable surgearresters (cont.)
r1 = 1P + N : Full Mode
r2 = 3P + N : Full Mode
-
8/19/2019 Domae Brochure 2014 (the Right Solution for Distribution Boards)
11/34
10
Functions
and characteristics
EZC100-1P.
EasyPact EZC circuit breakersFixed version
Plug-in version
Number of poles
Rated current (A) In at 40°C
Rated insulation voltage (V) Ui
Rated impulse withstand voltage (kV) Uimp
Rated operational voltage (V) Ue AC 50/60 Hz
DC
Electrical characteristics as per IEC 60947-2, EN 60947-2, JIS C8201-2-1
Ultimate breaking capacity (kA rms) Icu AC 50/60 Hz 110/130 V
220/230/240 V
380 V
400/415 V
440 V
550 V
DC 125 V (1P)
250 V(2P in series)
Rated service breaking capacity (kA rms) Ics % Icu 110-400 V
415-550 V
Suitability for isolation
EZC100-2P. Utilization category
Pollution degree
Endurance (C-O cycles) Mechanical
Electr ical In/415 V
Electrical characteristics as per NEMA-AB1
Breaking capacity (kA rms) HIC AC 50/60 Hz 240 V
277/480 V
Protection
Overload protection Bimetal
Instantaneous protection Magnetic Fixed (±20 %)
Auxiliaries
Indication contacts Auxiliary switch AX
Alarm switch AL
EZC100-3P. Combined AX + AL AXAL
Voltage releases Shunt trip release SHT
Undervoltage release UVR
Installation
Connection Crimp lugs/bars
Accessories Box lugs for bare cables
Rotary handles Direct
Extended
Terminal extensions
Spreaders
Phase barriersTerminal shields
Padlocking system
EZC100-4P. DIN rail adaptor
Dimension and weight
Dimensions (mm) D x H
W
Weight (kg)
EZC250-3P.
Selection table
C P B 1 0 0 6 0 0
C P B 1 0 0 6 0 1
C P B 1 0 0 6 0 2
C P B 1 0 0 6 0 3
C P B 1 0 0 6 0 4
-
8/19/2019 Domae Brochure 2014 (the Right Solution for Distribution Boards)
12/34
11
EZC100B EZC100F EZC100N EZC100H EZC250F EZC250N EZC250H■ ■ ■ ■ ■ ■ ■ ■ ■
■ ■ - ■ (4) - ■ (4) ■ ■ ■
3 3 1 3-4 1 2-3-4 3 3 2-3
15, 16, 20, 25,30, 32, 40, 45,50, 60
15, 16, 20, 25,30, 32, 40, 45,50, 60, 63, 75,80, 100
15, 16, 20, 25,30, 32, 40, 45,50, 60, 63, 75,80, 100
15, 16, 20, 25,30, 32, 40, 45,50, 60, 63, 75,80, 100
15, 16, 20, 25,30, 32, 40, 45,50, 60, 63, 75,80, 100
15, 16, 20, 25,30, 32, 40, 45,50, 60, 63, 75,80, 100
100, 125, 150,160, 175, 200,225, 250
100, 125, 150,160, 175, 200,225, 250
100, 125, 150,160, 175, 200,225, 250
690 690 690 690 690 690 690 690 690
6 6 6 6 6 6 6 6 6
550 550 415 550 415 550 550 550 550
- 250 125 250 125 250 250 250 250
10 25 25 25 50 100 25 50 85
10 25 18 25 25 100 (1) 25 50 85
7.5 10 2.5 18 5 30 18 25 36
7.5 10 2.5 15 5 30 18 25 36
5 7.5 - 10 - 20 15 20 25
2.5 5 - 5 - 10 5 8 10
- 5 5 5 10 10 5 20 30
- 5 - 5 - 10 5 20 30
25 % 50 % 50 % 50 % 50 % 50 % 50 % 50 % 50 %
25 % 50 % 50 % 50 % 50 % 25 % 50 % 50 % 50 %
■ ■ ■ ■ ■ ■ ■ ■ ■
A A A A A A A A A
3 3 3 3 3 3 3 3 3
8 500 8 500 8 500 8 500 8 500 8 500 10 000 10 000 10 000
1 500 1 500 1 500 1 500 1 500 1 500 5 000 5 000 5 000
- - 10 25 18 100 25 50 85
- - 10 (2) 10 18 (2) 18 (3) 15 18 25 (3)
fxed fxed fxed fxed fxed fxed fxed fxed fxed
fxed fxed fxed fxed fxed fxed 10 In 10 In 10 In
■ ■ - ■ - ■ ■ ■ ■
■ ■ - ■ - ■ ■ ■ ■
■ ■ - ■ - ■ ■ ■ ■
■ ■ - ■ - ■ ■ ■ ■
■ ■ - ■ - ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■ ■
■ ■ - ■ - ■ (3) ■ ■ ■
■ ■ - ■ - ■ (3) ■ ■ ■
- - - - - - ■ ■ ■
■ ■ - ■ - ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■ ■
■ ■ - ■ - ■ (3) ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ - - -
60 x 130 60 x 130 60 x 130 60 x 130 60 x 130 60 x 130 60 x 165 60 x 165 60 x 165
75 75 25 75 (3P)100 (4P)
25 50 (2P)75 (3P)100 (4P)
105 105 105
0.78 0.78 0.28 0.78 (3P)1.0 (4P)
0.28 0.6 (2P)0.78 (3P)1.0 (4P)
1.3 1.3 1.1 (2P)1.3 (3P)
(1) 50 kA for 2 poles.(2) For 277 V only.(3) For 3 and 4 poles only.(4) For 3P only.
-
8/19/2019 Domae Brochure 2014 (the Right Solution for Distribution Boards)
13/34
12
P B 1 0 4 6 7 4 - 9 0
P B 1 0 4 6 3 1 - 9 0
Entry by cable, tube or
trunking
Blanking plates
Large space for cabling
A white opaque or translucent
or smoked transparent door b Reversible opens to 140°, after
which it can be removed, withoutbreaking
Removable front face b With insulating screen b White colour available
Base with pre-holes b Clamping leg for hollow partition
b Carton protection for installation inmasonry
Options b Marker light: ensures that the
electrical functions can be accessed
in the event of a general powersupply failure
b Phase terminal block b Kit IP 41 b Keylock
Earth and neutral terminal
block b Clipped with quick connection
Removable chassisb 1 to 3 DIN rails adjustableasymmetrically
Presentation Mini PragmaFlush mounting enclosuresOffer: with earth + neutral terminal blocks
The ush mounting
enclosuresiThe range consists of enclosures with a width of 4,
6, 8, 12, 18, 24 or 36- module of 18mm, of 1, 2 or
3-row ready-to-use; designed for electricians:
ergonomic design and exibility of installation.
Easy installation and large cabling space
The chassis shapes are rounded and are not
wounding for the cable and nger.
Mini Pragma is a robust modular enclosure (IK 07),
aesthetic with innovative design; highly suitable for
a living environment integration. It offers great
security (IP 40, IP 41, with accessory) thanks to the
front face with a white opaque or translucent door
models on all models, or smoked transparent for
models with earth + neutral terminal block.
P B 1 0 4 1 0 2 - 4 7
P B 1 0 4 0 8 9 - 2 5
P B 1 0 4 0 9 1 - 2 5
36-module enclosures 18-module enclosures 4-module enclosures
-
8/19/2019 Domae Brochure 2014 (the Right Solution for Distribution Boards)
14/34
13
Functions
and technical dataMini PragmaFlush mounting enclosuresOffer: with earth + neutral terminal blocks
A range of 18mm, 1, 2 or 3-row 4, 6, 8, 12, 18, 24 or
36-module ready-to-use enclosures designed for
electricians: ergonomic design and flexibility
of installation.
FunctionThis distribution or sub-distribution enclosure, up to 63 A, is designed for installing
electrical switchboards in new or renovated installations in the housing sector.
DescriptionTwo choices are possible:
Offer to composeThis offer can compose the enclosures according to their own preference, based on
a choice of 5 colours of different front face and a large number of accessories.
OR
Offer composed This offer allows having for a single reference a complete enclosure equipped with:
b a symmetrical back box v robust
v depth adapted to the walls of reduced thickness
v with pre-holes for entry tubes on the 4 sides
b 1 to 3 rails DIN, chassis allows the cabling outside the back box
b a rigid and reversible white (RAL 9003) front face, tted with pre-cutout blanking
plates with white opaque or translucent door or smoked transparent door
b an earth and neutral terminal block
This enclosure can be equipped with a marker light, available in accessories.It allows locating the enclosure in the dark during a power failure.
P B 1 0 4 0 8 5 - 4 0
P B 1 0 4 0 8 3 - 2 9
P B 1 0 4 0 8 1 - 2 1
P B 1 0 4 0 7 9 - 2 2
P B 1 0 4 0 7 7 - 2 0
P B 1 0 4 0 7 1 - 4 0
P B 1 0 4 0 7 3 - 1 9
36-moduleenclosures
24-moduleenclosures
18-moduleenclosures
12-moduleenclosures
8-moduleenclosures
6-moduleenclosures
4-moduleenclosures
Technical dataEnclosuresCompliance with standards IEC 60439-3, IEC 60529,
IEC 60695-2-11, EN 50102,IEC 60670-24
Rated current (In) 4-module enclosure 50 A
6 to 36-module enclosures 63 A
Rated insulation voltage (Ui) < 400 VInsulation Class 2 (to IEC 60439-3)
Degree of protection To IEC 60529 IP 40
Against mechanical impacts IK 07
Materials Self-extinguishing technoplastic (1): resistant to fre and abnormal
heat 650°C to IEC 60695-2-11
(1) Technoplastic material specially developed by Schneider Electric.
P B 1 0 4 0 9 6 - 5 0
P B 1 0 4 1 0 8 - 2 0
Smoked translucent door.
P B 1 0 4 1 0 7 - 2 0
White door.
-
8/19/2019 Domae Brochure 2014 (the Right Solution for Distribution Boards)
15/34
14
Functions
and technical dataMini PragmaFlush mounting enclosures (cont.)Offer: with earth + neutral terminal blocks
Components delivered with each enclosure
TypeIdentication strip for each row To be glued onto the front panel
Two terminal block supports
Two earth/neutral terminalblocks
Supplied with the 4 or6-module enclosure
2 x (1 x 16 v + 2 x 10 v + 1 x 6 v)
Supplied with the 8 or12-module enclosure
2 x (1 x 16 v + 4 x 10 v + 3 x 6 v)
Supplied with the 18 or24-module enclosure
2 x (2 x 16 v + 8 x 10 v + 6 x 6 v)
Supplied with the36-module enclosure
2 x (2 x 16 v + 9 x 10 v + 9 x 6 v)
Blanking plates (packs of 10) Clipped on the front face
P B 1 0 4 0 7 3 - 3 6
MIP20104T
Offer composed with earth and neutralterminal blocksWhite enclosures Cat. no.Number ofrows
Number ofmodules perrow
Capacity in 18mm modules
Rated currentIn (A)
With solidwhite door
With smokedtranslucentdoor
1 4 4 50 MIP22104 MIP22104T
6 6 63 MIP22106 MIP22106T
8 8 63 MIP22108 MIP12108T
12 12 63 MIP22112 MIP22112T
18 18 63 MIP22118 MIP22118T
2 12 24 63 MIP22212 MIP22212T
3 12 36 63 MIP22312 MIP22312T
-
8/19/2019 Domae Brochure 2014 (the Right Solution for Distribution Boards)
16/34
15
P B 1 0 4 6 7 5 - 9 0
P B 1 0 4 6 3 2 - 9 0
Presentation Mini PragmaSurface mounting enclosuresOffer: with earth + neutral terminal block
The surface mounting
enclosuresiThe range consists of enclosures with a width of 4,
6, 8, 12, 18, 24 or 36- module of 18mm, of 1, 2 or
3-row ready-to-use; designed for electricians:
ergonomic design and exibility of installation.
Easy installation and large cabling space
The chassis shapes are rounded and are not
wounding for the cable and nger.
Mini Pragma is a robust modular enclosure (IK 07),
aesthetic with innovative design; highly suitable
for a living environment integration. It offers great
security (IP 40, IP 41, with accessory) thanks to the
front face with a white opaque or translucent door
models on all models, or smoked transparent for
models with earth + neutral terminal block.
P B 1 0 4 0 7 1 - 4 0
P B 1 0 4 0 6 7 - 2 1
P B 1 0 4 0 5 8 - 3 0
36-module enclosures 18-module enclosures 4-module enclosures
Insulating edge
Removable front face b With insulating screen
Blanking plates
Entry by cable, tube or
trunking
DIN rails b 1 to 3 DIN rails xed
asymmetrically
A white opaque or translucent
or smoked transparent door b Reversible opens to 140°, after
which it can be removed, withoutbreaking
Options b Marker light: ensures that the
electrical functions can be accessed
in the event of a general powersupply failure b Phase terminal block b Kit IP 41 b Keylock
Earth and neutral terminal
block b Clipped with quick connection
Fixation b The back tting with 4 oblong
holes is sturdy and allows verticaladjustment
Entry by cable, tube or
trunking
Removable cable entry plates b Located at the top and bottom of
the enclosure, they offer wide accessand allow easy association
Large space for cabling
-
8/19/2019 Domae Brochure 2014 (the Right Solution for Distribution Boards)
17/34
16
Functions
and technical dataMini PragmaSurface mounting enclosuresOffer: with earth + neutral terminal block
A range of 18mm, 1, 2 or 3-row 4, 6, 8, 12, 18, 24 or
36-module ready-to-use enclosures designed for
electricians: ergonomic design and flexibility
of installation.
FunctionThis distribution or sub-distribution enclosure, up to 63 A, is designed for installing
electrical switchboards in new or renovated installations in the housing sector.
DescriptionThe surface mounting Mini Pragma consists of:
b a back with:
v a centered slot to facilitate installation
v xing holes for vertical adjustment
b the necessitate for entry cables: v two removable cable entry plates at the top and bottom
v punch-outs
v a large area for drill ing (crown saw, punches)
b 1 to 3 DIN rails xed asymmetrically onto the back b a reversible front face, tted with pre-cutout blanking plates
b a white opaque or translucent door or smoked transparent
b an earth terminal block and a neutral terminal block
Enclosure colour: White RAL 9003
This enclosure can be equipped with a marker light, available in accessories.
It allows locating the enclosure in the dark during a power failure.
Technical dataEnclosures
Compliance with standards IEC 60439-3, IEC 60529,IEC 60695-2-11, EN 50102,IEC 60670-24
Rated current (In) 4-module enclosure 50 A
6 to 36-module enclosures 63 A
Rated insulation voltage (Ui) < 400 V
Insulation Class 2 (as per IEC 60439-3)
Degree of protection To IEC 60529 IP 40
Against mechanical impacts IK 07
Materials Self-extinguishing technoplastic (1): resistant to re and abnormalheat 650°C to IEC 60695-2-11
(1) Technoplastic material specially developed by Schneider Electric.
P B
1 0 4 0 7 1 - 4 0
P B
1 0 4 0 6 9 - 2 9
P B
1 0 4 0 6 7 - 2 1
P B
1 0 4 0 6 5 - 2 2
P B
1 0 4 0 6 3 - 2 0
P B
1 0 4 0 6 4 1 - 1 9
P B
1 0 4 0 5 9 - 2 0
36-moduleenclosures
24-moduleenclosures
18-moduleenclosures
12-moduleenclosures
8-moduleenclosures
6-moduleenclosures
4-moduleenclosures
P B 1 0 4 1 0 8 - 2 0
Smoked translucent door
P B 1 0 4 1 0 7 - 2 0
White door
-
8/19/2019 Domae Brochure 2014 (the Right Solution for Distribution Boards)
18/34
17
Functions
and technical dataMini PragmaSurface mounting enclosuresOffer: with earth + neutral terminal block
Components delivered with each enclosure
Type
Insulating plug (pack of 4) To be placed over the back xing screws to obtain class 2
insulationIdentication stripfor each row
To be glued onto the front panel
Two terminal block supports
Two earth/neutral terminalblocks
Supplied with the 4or 6-module enclosure
2 x (1 x 16 v + 2 x 10 v + 1 x 6 v)
Supplied with the 8or 12-module enclosure
2 x (1 x 16 v + 4 x 10 v + 3 x 6 v)
Supplied with the 18or 24-module enclosure
2 x (2 x 16 v + 8 x 10 v + 6 x 6 v)
Supplied with the 36-moduleenclosure
2 x (2 x 16 v + 9 x 10 v + 9 x 6 v)
Blanking plates (packs of 10) Clipped on the front face
P B 1 0 4 0 5 9 - 3 5
MIP10104T
P B 1 0 4 6 5 0 - 3 0
Insulating plug
Catalogue numbers
White enclosures Cat. no.
Number ofrows
Number ofmodules perrow
Capacity in 18mm modules
Rated currentIn (A)
With solidwhite door
With smokedtranslucentdoor
1 4 4 50 MIP12104 MIP12104T
6 6 63 MIP12106 MIP12106T
8 8 63 MIP12108 MIP12108T
12 12 63 MIP12112 MIP12112T
18 18 63 MIP12118 MIP12118T
2 12 24 63 MIP12212 MIP12212T
3 12 36 63 MIP12312 MIP12312T
-
8/19/2019 Domae Brochure 2014 (the Right Solution for Distribution Boards)
19/34
18
Accessories Mini PragmaFlush / Surface mounting enclosures
Accessories for enclosures
Finishing accessories Cat. no. Type Description Solid white
Used to cover empty slots
b 5 dividable modules
b Colour: white RAL 9003
b Supplied in packs of 10
Is illuminated when the terminal block voltage of the
light is 0 V. It has a continuous supercapacitor powersupply that needs no battery, accumulator or
maintenance
b White LED b Autonomy: 20 mn
b Light output: 5 lumens b Supply voltage: 240 V AC max
b Recharge duration: 6 h
b Service life: 15 years
b Degree of protection: IP40, IK07
b Insulation class: 2 b Connection: 2.5mm2 max
b Withstand to re and abnormal heat: 750°C
13387
MIP99050
Blanking plate
Marker light
P B 1 0 4 1 2 5 - 2 0
P B 1 0 4 6 7 3 - 2 0
-
8/19/2019 Domae Brochure 2014 (the Right Solution for Distribution Boards)
20/34
19
ARA automatic reclosersFor iC60 circuit breakersand iID residual current circuit breakers
Control
Remote control
The ARA reclosing auxiliary can:
b Perform automatic reclosing of the associated protection device, after tripping.
b Increase the availability of installations without supervision, isolated, hard of
access and demanding very great availability (mobile telephony systems,motorways, pumping stations, airports, railways, meteorological stations, servicestations, automatic teller machines, public lighting, tunnels, etc.), by restoring them
to operation without intervention by personnel in the event of a transient fault
(atmospheric disturbances, industrial overvoltages, etc.).
b For the ARA iC60, the operator can choose predened reclosing program which
allows the safety and availability of facilities to be reconciled taking into account the
facility's environment.
b The circuit is placed in safety conguration by the padlocking device.
Catalogue numbers
ARA iC60For circuit breaker Width in 9mm
modules
1P, 1P+N, 2P Number ofprograms
Voltage
4 230 V AC, 50/60 Hz A9C70132 7
3P, 4P
4 230 V AC, 50/60 Hz A9C70134 7
ARA iID
For residual current circuit breaker Width in 9mm
modules
2P Number ofprograms
Voltage
1 230 V AC, 50/60 Hz A9C70342 7
4P1 230 V AC, 50/60 Hz A9C70344 7
Auxiliaries Refer to sales team
Diagram
2221
OF
24 141112
N P
Y2Y1
ARA
Locked
Legend
Type Application
21
34
Choice of program (ARA iC60)
Y1 "Remote" inhibition of automatic reclosing
Y2 Remote control of nal reclosing
N 230 V power supply
P
Locked
21 22 24
Automatic recloser inhibition indication contact
OF
11 12 14
Indicates the state of the circuit breaker or residual currentcircuit breaker (opened or closed)
Indicatorlamp
Flashing green ARA automatic recloser operational
Flashing red Reclosing cycle in progress
Fixed red ARA automatic recloser locked at end of reclosingcycle: circuit breaker or residual current circuitbreaker tripped (open)
Flashing orange ARA automatic recloser not operational
D B 1 2 4 0 6 0
D B 1 2 3 5 8 2
ARA iC60
D B 1 2 3 5 8 3
D B 4 0 6 1 7 9
ARA iID
230 V
iC60 or iID
D B 1 2 4 0 6 1
ARA iC60
ARA iID
P B 1 0 6 2 5 6 - 4 0
D B 1 2 4 0 6 5
P B 1 0 6 2 5 7 - 4 0
-
8/19/2019 Domae Brochure 2014 (the Right Solution for Distribution Boards)
21/34
20
ARA automatic reclosers (cont.)For iC60 circuit breakersand iID residual current circuit breakers
Control
Remote control
Operating principleThe ARA automatic recloser makes a number of attempts at reclosing depending on
the program chosen by the user.
The program includes the following settings:b A time delay before reclosing (TA).
b A reinitialization time delay (TB).
b A maximum number of reclosing attempts.If, following these attempts, the fault is still present, the device places itself in waiting
for manual reclosing, or nal remote reclosing (Y2).
ARA iC60 Number of
reclosing
attempts
Delay
before
reclosing
Check time Final
reclosing Y2
TA TB
Program
21
34
1 60 s 6 min. Once afterinhibition
21
34
3 60 s3 min.3 min.
2 min.6 min.6 min.
21
34
5 60 s3 min.3 min.3 min.3 min.
2 min.6 min.6 min.6 min.6 min.
21
34
5 60 s3 min.4 min.5 min.6 min.
2 min.6 min.8 min.10 min.12 min.
ARA iID Number of
reclosing
attempts
Delay
before
reclosing
Check time Final
reclosing Y2
TA TB
Only 1 programavailable
15 20 s40 s3 min.3 min....
30 min.30 min....
Once per cycle
D B 1 2 4 0 6 1
D B 1 2 4 0 6 2
D B 1 2 4 0 6 3
D B 1 2 4 0 6 4
b Sealable cover
b Inhibition of automatic
recloser (auto - OFF) andresetting (Reset)
ARA iC60 b 4 predened
programs
b Placing in safety conguration by
integrated padlocking device (Ø 3 to 6mm)
b Bistable operation: does not
change state in the event ofelectrical power outage
b Manual control of thecircuit breaker or residual
current circuit breaker
always overrides automatic
control
b Manual remote control of
nal reclosing (after inhibitionof automatic recloser) (Y2)
b Remote inhibition of remotereclosing (Y1)
b Indication of ARA
operating states
P B 1 0 6 0 5 5 - 1 0 4
-
8/19/2019 Domae Brochure 2014 (the Right Solution for Distribution Boards)
22/34
21
Catalogue numbers
iC60H RCBO 100001P+N A Width in 9mm
modules
B curve Voltage rating (V) Sensitivity (IΔn) 10 mA 30 mA 100 mA
D B 4 0 5 0 3 8 240 Rating
(In)
6 A - A9D31806 - 2
10 A - A9D31810 -
16 A - A9D31816 -
20 A - A9D31820 -
25 A - A9D31825 -
32 A - A9D31832 -
40 A - A9D31840 -
45 A - A9D31845 -
C curve Voltage rating (V) Sensitivity (IΔn) 10 mA 30 mA 100 mA
D B 4 0 5 0 3 8 110 Rating
(In)10 A - A9D19810 - 2
16 A - A9D19816 -
20 A - A9D19820 -
25 A - A9D19825 -
32 A - A9D19832 -
240 Rating(In)
6 A A9D10806 A9D11806 A9D12806
10 A A9D10810 A9D11810 A9D12810
16 A A9D10816 A9D11816 A9D12816
20 A A9D10820 A9D11820 A9D12820
25 A A9D10825 A9D11825 A9D12825
32 A A9D10832 A9D11832 A9D12832
40 A A9D10840 A9D11840 A9D12840
45 A A9D10845 A9D11845 A9D12845
Operating frequency 50…60 Hz
Protect
Circuit protection
Accessory
Padlocking device b Used to lock the toggle in the "open" position by 3mm diameter padlock (not
supplied).
b The single-phase iC60H RCBO’s self-contained residual current device carries
out complete protection of nal circuits:
v protection against short-circuits and cable overloads
v protection of persons against electric shock by direct contact(10, 30 mA sensitivities),
v protection of persons against electric shock by indirect contact
(100 mA sensitivity),
v protection of equipment against re set by leakage currents
(100 mA sensitivity). b The neutral is not interrupted when the device is tripped. Hence iC60H RCBO can
be used on most circuits, except for the ones operating under TT or IT earthing
systems.
IEC 61009-1,
IEC 61009-2-2,
BS EN 61009-1AS/NZS 61009.1
D B 4 0 5 5 7 1
Country approval pictograms
iC60H RCBO10000 A10, 30 and 100 mA
Alternating current (AC) 50/60 Hz
Breaking capacity (Icn) according to IEC 61009-1
Voltage (Ue)
Ph/N 110 V 240 V
Rating (In) 6 to 45 A 10000 A 10000 A
P B 1 1 1 0 7 5 - 7 0
-
8/19/2019 Domae Brochure 2014 (the Right Solution for Distribution Boards)
23/34
22
Connection
D B 4 0 5 5 6 4
Type Rating Tightening torque Copper cables
Rigid Flexible
N in and L in 6 to 45 A 3.5 N.m 1 to 25mm2 1 to 16mm2
L out and N out 2 N.m 1 to 16mm2 1 to 10mm2
14mm 6.5mm
PZ2
13mm
5.5mm
PZ2
iC60 RCBO10, 30 and 100 mA
Protect
Circuit protection
b Test push-button
b Clip for dismounting
b Increased product service life thanks to fast closing independent of the speed ofactuation of the toggle.
b Remote indication, open/closed/tripped, by optional auxiliary contacts.
Visi-trip windowb Fault tripping is indicated by a red
mechanical indicator on the front face
Positive contact indication b The presence of the green strip guarantees
physical opening of the contacts and allows
operations to be performed on the downstream
circuit in complete safety
b Insulated terminals IP20
b Insulated terminals IP20
b Padlocking device
D B 1 2 2 9 4 5
D B 1 2 2 9 4 6
P B 1 1 1 0 7 5 - 7 0
D B 4 0 5 5 5 3
D B 4 0 5 5 5 6
D B 4 0 5 5 8 2
D B 4 0 6 3 1 9
-
8/19/2019 Domae Brochure 2014 (the Right Solution for Distribution Boards)
24/34
23
ARA automatic reclosersFor iC60 circuit breakersand iID residual current circuit breakers
Control
Remote control
Clip on DIN rail 35mm. Indifferent position of installation.
Dimensions (mm)
D B 1 2 3 5 6 7
99
117
135
81
63 3
97
80
44.55.5
6
85
2
45
702P (1P+N)
3P
4P
1P
D B 1 2 3 3 1 0
D B 1 2 3 3 1 2
-
8/19/2019 Domae Brochure 2014 (the Right Solution for Distribution Boards)
25/34
24
Dimensions (mm)
D B 1 2 3 3 9 2 72
54
3650
5.5
85
4.4
4.6
94
64
69.5
78.5
18
4P
3P
1P+N / 2P
1P
45
iC60H circuit breakers(curve C)
Clip on DIN rail 35mm. Indifferent position of installation.
D B 1 2 3 3 1 0
D B 1 2 3 3 1 2
iC60 RCBO10, 30 and 100 mA
Protect
Circuit protection
Clip on DIN rail 35mm.. Indif ferent posit ion of installation.
D B 1 2 3 3 0 9
D B 1 2 3 3 1 1
Dimensions (mm)
D B 4 0 5 5 6 5
110
1845 19
72
20
45
55 15
5.5
45 19
72
20
45
55 15
5.5
110
36
iC60H RCBO
-
8/19/2019 Domae Brochure 2014 (the Right Solution for Distribution Boards)
26/34
25
Dimensions (mm)
D B 1 2 3 5 9 6
1P 1P+N 2P
3P 3P+N 4P
Protection
Load protectioniPRD surge arrestersType 2 or 3 LV withdrawable surgearresters
iPF surge arrestersType 2 or 3 LV surge arresters
Dimensions (mm)
D B 1 2 3 5 9 5
1P 1P+N
2P 3P 3P+N 4P
-
8/19/2019 Domae Brochure 2014 (the Right Solution for Distribution Boards)
27/34
Modular switchgearProtect
Dimensions
Earth leakage switches
Domae RCCB mono-connect
187-0404
2 P
4 P
Domae MCB bi-connect
190-0404
4 P
3 P
2 P
1 P
PF
PRD
26
-
8/19/2019 Domae Brochure 2014 (the Right Solution for Distribution Boards)
28/34
Dimensions1P 2P 3P 4P
D B 1 1 1 9 7 3
D B 1 1 1 9 7 4
D B 1 1 1 9 7 5
D B 1 1 1 9 7 6
D B 1 1 5 2 5 4
Mounting on plate1P 2P
D B 1 1 1 9 7 7
D B 1 1 5 2 5 5
or
3P 4P
D B 1 1 1 9 7 9
D B 1 1 5 2 5 9
or
Mounting on DIN rail
D B 1 1 1 9 8 0
D B 1 1 1 9 8 1
D B 1 1 2 0 0 0
Dimensions EasyPact 100
27
-
8/19/2019 Domae Brochure 2014 (the Right Solution for Distribution Boards)
29/34
Door cut-out (small)1P, 3P 2P 4P
D B 1 1 1 9 8 2
D B 1 1 1 9 8 3
D B 1 1 1 9 8 4
D B 1 1 4 5 8 1
Door cut-out (large)1P 2P
D B 1 1 1 9 8 5
D B 1 1 1 9 8 6
D B 1 1 1 9 8 7
3P 4P
D B 1 1 1 9 8 8
D B 1 1 4 5 8 2
Dimensions EasyPact 100
28
-
8/19/2019 Domae Brochure 2014 (the Right Solution for Distribution Boards)
30/34
Dimensions (EZC250)2P, 3P 4P
D B 1 1 1 9 4 7
D B 1 1 1 9 4 8
D B 1 1 1 9 4 9
Mounting on plate2P, 3P 4P
D B 1 1 1 9 5 3
D B 1 1 1 9 5 4
19.5
50
102
144
44
22
100
105
35 35
52.5
25
19.5
50
102
144
44
22
100
105
35 35
52.5
25
Dimensions EasyPact 250
29
-
8/19/2019 Domae Brochure 2014 (the Right Solution for Distribution Boards)
31/34
Dimensions EasyPact 250
Door cut-out (small)2P, 3P 4P
D B 1 1 1 9 5 5
D B 1 1 1 9 5 6
D B 1 1 1 9 5 7
Door cut-out (large)2P, 3P 4P
D B 1 1 1 9 5 8
D B 1 1 1 9 5 9
D B 1 1 1 9 6 0
Dimensions (mm)
A B C D E F
EZC 2/3P 60 65 85.5 - 67 61
EZC 4P 68 73 95 - 75 69
30
-
8/19/2019 Domae Brochure 2014 (the Right Solution for Distribution Boards)
32/34
Dimensions Mini Pragma Surface mounting enclosures
1 9 8
2 2 8
3 5 3
4 7 8
102
102
101.5
95
1 2 5
1 2 5
1 2 5
1 2 6 . 5
1 0 1 . 5
1 0 1 . 5
1 2 6 . 5
1 2 6 . 5
1 0 1 . 5
9 6 . 5
1 0 1 . 5
17 23 23 23
124
160196
268
376
1 9 8
268
3 5 3
267
4 7 8
2 2 8
Front view
Side view
4, 6 modules 24 modules
36 modules
4, 6 modules 24 modules 36 modules
D B 1 2 2 7 3 8
8, 12, 18 modules
8, 12, 18 modules
1 4 3
93 165
1 7 0
273
2 9 5
165
4 2 0
1 4 3 1
7 0
1 7 0
165
Inside view
4 modules 12 modules
D B 1 2 2 7 3 9
6 modules 8 modules
18 modules 24 modules 36 modules
31
-
8/19/2019 Domae Brochure 2014 (the Right Solution for Distribution Boards)
33/34
Mini PragmaFlush mounting enclosures
Dimensions
1 0 2
2 5 2
150
186
222
294
402
294
1 0 2
3 7 7
294
1 0 2
5 0 2
8070
60.519.5
Ø13
Ø13
Ø13
Ø20
Ø20
Ø13Ø13Ø13
80
70
70
18
80 18
18
1 2 5
2 2 8
3 5 3
4 7 8
1 2 5
1 2 5
126
63
Ø20
Ø20
Ø20 Ø20
162 198
55 5544
Ø16 Ø20Ø16
270
47 44 47
378
57 44 57
Ø16
Front view
Side view
Top view
4, 6, 8, 12, 18 modules 24 modules
36 modules4, 6, 8, 12, 18 modules 24 modules 36 modules
4 modules 6 modules 8 modules 12, 24, 36 modules
18 modules
D B 1 2 3 2 8 3
32
-
8/19/2019 Domae Brochure 2014 (the Right Solution for Distribution Boards)
34/34
As standards, specifications and designs
change from time to time, please ask for
confirmation of the information given in this
publication.
Design, production, illustrations:
Schneider Electric SA
Printed in Malaysia
Schneider Electric (M) Sdn Bhd (139220-D)Schneider Electric Industries (M) Sdn Bhd (378576-M)Headquarters
Unit TB-18-2, Level 18, Tower B,
Plaza 33, No. 1, Jalan Kemajuan,
Seksyen 13, 46200 Petaling Jaya,
Selangor, Malaysia
Tel : (603) 7883 6333
Fax : (603) 7883 6188
Email : [email protected] CareCentre: 1-800-880-877
Nationwide BranchesJohor Bahru
Tel : (607) 351 3801 / 802
Fax : (607) 351 4113
Penang
Tel : (604) 643 8187 / 175
Fax : (604) 643 9197
Kota Kinabalu
Tel : (6088) 237 000 / 012
Fax : (6088) 216 900
Kuching
Tel : (6082) 450 242
Fax : (6082) 450 373