domagoj damjanoviĆ - unizg.hr...test protocol the cyclic horizontal load protocol is composed...

8
associate profesor DOMAGOJ DAMJANOVIĆ Construction Testing Laboratory Faculty of Civil Engineering University of Zagreb

Upload: others

Post on 23-Jan-2021

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: DOMAGOJ DAMJANOVIĆ - unizg.hr...Test protocol The cyclic horizontal load protocol is composed ofthree sets rules: Definition of a yielding point (the Yasumura and Kawai (1997) procedure

associate profesor DOMAGOJ DAMJANOVIĆ Construction Testing Laboratory

Faculty of Civil Engineering

University of Zagreb

Page 2: DOMAGOJ DAMJANOVIĆ - unizg.hr...Test protocol The cyclic horizontal load protocol is composed ofthree sets rules: Definition of a yielding point (the Yasumura and Kawai (1997) procedure

Test set-up

Setup A Setup B

Page 3: DOMAGOJ DAMJANOVIĆ - unizg.hr...Test protocol The cyclic horizontal load protocol is composed ofthree sets rules: Definition of a yielding point (the Yasumura and Kawai (1997) procedure

Test protocol The cyclic horizontal load protocol is composed of three sets of rules:

Definition of a yielding point (the Yasumura and Kawai (1997) procedure for timber shear wall)

Cyclic protocol EN 12512:2001 in the range of low displacement amplitudes (up to 2dy)

Cyclic protocol ATC-24 in the range of high displacement amplitudes (over 2dy)

Displacement (mm)

Hori

zo

nta

l fo

rce

(kN

)

EN 12512 ([%]*dy) ATC-24 ([%]*h or +0.5 dy)

v=0.25 mm/s

v=0.5 mm/s v = 1 mm/s

Time (s)

Sto

ry d

rift [

h/d

] (%

)

dy

2 d

y

Page 4: DOMAGOJ DAMJANOVIĆ - unizg.hr...Test protocol The cyclic horizontal load protocol is composed ofthree sets rules: Definition of a yielding point (the Yasumura and Kawai (1997) procedure

Test protocol

Displacement (mm)

Hori

zo

nta

l fo

rce

(kN

)

EN 12512 ([%]*dy) ATC-24 ([%]*h or +0.5 dy)

v=0.25 mm/s

v=0.5 mm/s v = 1 mm/s

Time (s)

Sto

ry d

rift [

h/d

] (%

)

dy

2 d

y

Specimens of each type of joints were loaded by monotonous lateral loads until reaching a 20% drop of load bearing capacity to obtain the load-deformation curve which was used to determine the displacement at a yielding point (dy)

The range of low amplitudes is divided into parts concerning the actuator velocity of 0,25 mm/s up to displacement amplitude equal to dy and velocity of 0,50 mm/s up to a displacement amplitude of 2dy.

Page 5: DOMAGOJ DAMJANOVIĆ - unizg.hr...Test protocol The cyclic horizontal load protocol is composed ofthree sets rules: Definition of a yielding point (the Yasumura and Kawai (1997) procedure

Test protocol

Displacement (mm)

Hori

zo

nta

l fo

rce

(kN

)

EN 12512 ([%]*dy) ATC-24 ([%]*h or +0.5 dy)

v=0.25 mm/s

v=0.5 mm/s v = 1 mm/s

Time (s)

Sto

ry d

rift [

h/d

] (%

)

dy

2 d

y

After reaching the limit of 2dy the speed of actuator increased to 1,00 mm/s

Three cycles of loading were performed for each selected amplitude

Testing ended when the complete failure of joints was achieved

Page 6: DOMAGOJ DAMJANOVIĆ - unizg.hr...Test protocol The cyclic horizontal load protocol is composed ofthree sets rules: Definition of a yielding point (the Yasumura and Kawai (1997) procedure

Test results for Φ10 mm threaded glued–in steel bar and Setup A

for Φ10 mm threaded glued–in steel bar and Setup B

failure due to timber compressive crushing and reaching tensile strength of steel bar

Page 7: DOMAGOJ DAMJANOVIĆ - unizg.hr...Test protocol The cyclic horizontal load protocol is composed ofthree sets rules: Definition of a yielding point (the Yasumura and Kawai (1997) procedure

Test results for Φ14 mm threaded glued–in steel bar and Setup A

for Φ14 mm threaded glued–in steel bar and Setup B

failure due to timber compressive crushing

Page 8: DOMAGOJ DAMJANOVIĆ - unizg.hr...Test protocol The cyclic horizontal load protocol is composed ofthree sets rules: Definition of a yielding point (the Yasumura and Kawai (1997) procedure

Test demonstration for Φ20 mm threaded glued–in steel bar and Setup A