CIENA CONFIDENTIAL AND PROPRIETARY
ONLINE7000/9000/11000TRANSPORT PLATFORM
ALARMAND TROUBLECLEARING MANUAL
Software Release 6.0
CIENA Part Number: 009-2003-078
Revision A
April 30, 2003
-
7/29/2019 009-2003-078 Alarm and Trouble Clearing.pdf
2/106
CIENA
CONFIDENTIAL AND PROPRIETARY
LEGAL NOTICES
THIS DOCUMENT CONTAINS CONFIDENTIAL AND TRADE SECRET INFORMATION OF CIENA CORPORATION
AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE OR DISCLOSE ITS
CONTENTS, OR TO MANUFACTURE, USE, OR SELL ANYTHING THAT IT MAY DESCRIBE. REPRODUCTION,
DISCLOSURE, OR USE IN WHOLE OR IN PART WITHOUT THE SPECIFIC WRITTEN AUTHORIZATION OF CIENA
CORPORATION IS STRICTLY FORBIDDEN.
EVERY EFFORT HAS BEEN MADE TO ENSURE THAT THE INFORMATION IN THIS DOCUMENT IS COMPLETE
AND ACCURATE AT THE TIME OF PRINTING; HOWEVER, THE INFORMATION CONTAINED IN THIS DOCUMENT
IS SUBJECT TO CHANGE.
Copyright 2003 CIENA Corporation
Unpublished All Rights Reserved
The material contained in this document is also protected by copyright laws of the United States of America and other
countries. It may not be reproduced or distributed in any form by any means, altered in any fashion, or stored in a data
base or retrieval system, without express written permission of the CIENA Corporation.
Required Customer InformationPart 15 of the Federal Communications Commission (FCC): Interference
CIENA NOTE: Every effort has been made to ensure that this equipment is designed to comply with the limits for a
Class A digital device, as described in the FCC Rules. Equipment limitations are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial environment. This equipment,
if not installed and used properly, and in accordance with guidelines established by CIENA Corporation may cause
interference with other communications equipment. Operation of this equipment in a residential environment may
cause interference and is the responsibility of the user to correct the interference at his own expense.
Security
CIENA cannot be responsible for unauthorized use of equipment and will not make allowance or credit for
unauthorized use or access.
Contacting CIENA
Corporate Headquarters 410-694-5700 www.ciena.com
Customer Technical Support/Warranty
In North America 1-800-CIENA24 (243-6224) E-mail: [email protected]
In Europe00800 843 52 322
or +44 181 843 52 322E-mail: [email protected]
In Asia 0120-884-766
Sales and General Information 410-694-5700 E-mail: [email protected]
In North America 410-694-5700 E-mail: [email protected]
In Europe 44 207 389 7100 E-mail: [email protected]
In Asia +81-3-3248-4680 E-mail: [email protected]
Training and Documentation
Training877-CIENA-TD (243-6283)
or 410-694-8120E-mail: [email protected]
Documentation877-CIENA-TD (243-6283)
or 410-694-8125E-mail: [email protected]
-
7/29/2019 009-2003-078 Alarm and Trouble Clearing.pdf
3/106
ONLINETM7000/9000/11000 PREFACE
Alarm and Trouble Clearing Manual
April 30, 2003 - Revision A
009-2003-078 i
CIENA CONFIDENTIAL AND PROPRIETARY
PREFACE
The ONLINE 7000/9000/11000 Transport PlatformAlarm and Trouble Clearing Manual describes the
ONLINE alarm tools that are available from the various ONLINE control applicationsat the graphical craft
interface terminal (GCIT), command line interface (CLI), Transaction Language 1 (TL1) messages, and
SNMP. This manual is also a resource that explains the basic ONLINE system fault management principles,
describes each ONLINE system alarm, and identifies the actions needed to correct the alarm condition.
This preface defines the purpose, readership, and organization of the ONLINE Alarm and Trouble Clearing
Manual in the following sections:
! Objectives
! Audience
! Content Organization
! Related Documentation
! Contacting CIENA System Technical Field Return Information
! Lab Evaluation and Field Trials
OBJECTIVES
This manual provides overviews of the alarm tools available from all of the ONLINE software application
platforms. You can use this manual as a quick resource to decipher the meanings of alarms, and to locate
recommended actions to take in response to alarms. This manual supplements the information found in
other ONLINE manuals, as listed in the Related Documentationsection of this preface.
AUDIENCE
This manual is intended for network technicians who perform routine maintenance and deal with alarm
conditions that arise after the network element (NE) has been installed successfully according to the
ONLINE Install, Turn-Up, & Test Manualand has been in operation for some time.
DISCLAIMER
Portions of this document are intended solely as an outline of methodologies to be followed during the
maintenance and upgrade of an ONLINE Transport Platform. It is not intended as a step-by-step guide or
a complete set of all procedures necessary and sufficient to complete an upgrade.
While every effort has been made to ensure that this document is complete and accurate at the time of
printing, the information that it contains is subject to change. CIENA is not responsible for any additions to
or alterations of the original document. Networks vary widely in their configurations, topologies, and traffic
conditions. This document is intended as a general guide only. It has not been tested for all possible
applications, and it may not be complete or accurate for some situations.
Users of this document are urged to heed warnings interspersed throughout the document, such as traffic
disruption warnings.
-
7/29/2019 009-2003-078 Alarm and Trouble Clearing.pdf
4/106
PREFACE ONLINETM7000/9000/11000
Alarm and Trouble Clearing Manual
April 30, 2003 - Revision A
ii 009-2003-078
CIENA CONFIDENTIAL AND PROPRIETARY
CONTENT ORGANIZATION
This manual contains the following sections:
! CHAPTER 1, FAULT MANAGEMENT
! CHAPTER 2, USER ALARMS
! CHAPTER 3, ALARM CLEARING PROCEDURES
! APPENDIX A, ALARM MESSAGE LIST
RELATED DOCUMENTATION
This manual assumes that the reader is already familiar with the following ONLINE manuals:
! ONLINE Install, Turn-Up, & Test Manual: Includes instructions for installing and turning up an
NE. If your NE has not yet been successfully installed, or has not operated successfully, refer
to these guides.
! Circuit Pack Reference Guide: Contains specific information about each circuit pack (CP) in
the NE, including block diagrams and part numbers.
! OPTX Management Suite Graphical CIT User Guide: Provides the information to provision anode and perform any required maintenance and troubleshooting tasks.
! ONLINE CLI Reference: Provides details for all currently supported ONLINE system CLI
instructions and responses.
! ONLINE TL1 Reference: Provides details for all currently supported ONLINE system
Transaction Language 1 (TL1) instructions and messages.
! ONLINE SNMP Reference: Provides details about all SNMP MIBs and the SNMP master
agent.
COMPLIANCE INFORMATION
Food and Drug Administration (FDA) Laser Safety Warning
This product contains a laser diode. CIENA Corporation strongly recommends that users, maintenance, and
service personnel comply with the following standards and regulations in the design, modification,
operation, maintenance, an service of lasers and fiber-optic devices:
It is further recommended that the owner of this equipment determine and ensure conformance with any
specific and applicable local regulations.
Jurisdiction Type Title
Federal, US Regulation FDA 21 CFR 1040.10/.11
Federal, US Guidelines OSHA
International Standard ANSI Z136 series
International Standard IEC-825 series
International Standard EN-60825
-
7/29/2019 009-2003-078 Alarm and Trouble Clearing.pdf
5/106
ONLINETM7000/9000/11000 PREFACE
Alarm and Trouble Clearing Manual
April 30, 2003 - Revision A
009-2003-078 iii
CIENA CONFIDENTIAL AND PROPRIETARY
Class I Laser Product Notice
The CIENA Corporation ONLINE Metro Transport Platform product is a Class 1 Laser product as
identified by US FDA/CDRH 21CFR1040.10/.11; Class 1 Laser product as defined by IEC825/EN-60825;
and OFCS SG1 as defined by ANSI Z136.1/.2/
Part 15 of the Federal Communications Commission (FCC): Interference
Every effort has been made to ensure that this equipment is designed to comply with the limits for a Class
A digital device, as described in the FCC Rules. Equipment limitations are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial environment. This
equipment, if not installed and used properly, and in accordance with guidelines established by CIENA
Corporation may cause interference with other communications equipment. Operations of this equipment in
a residential environment may cause interference and is the responsibility of the user to correct the
interference at the users own expense.
Environmental Impact Statement
CIENA equipment contains no hazardous materials as defined by the United States Environmental
Protection Agency (USEPA). CIENA
recommends that all failed product be returned to CIENA
for failureanalysis and proper disposal.
Toxic Emissions
CIENA equipment releases no toxic emissions.
Telcordia Document Standards
The format and structure of this document is derived from the Telcordia Generic Requirements for Supplier-
Provided Documentation, GR-454-CORE.
TRADEMARK ACKNOWLEDGEMENTS
! CIENA is a registered trademark of CIENA Corporation.
! ONLINE7000/9000/11000 Transport Platform is a trademark of CIENA Corporation.
! Windows 95/98/2000 and Windows NT are registered trademarks of the Microsoft
Corporation.
! UNIX is a registered trademark licensed exclusively through X/Open Company, Ltd.
! Pentium is a registered trademark of Intel Corporation.
! Sun, Sun Microsystems, JAVA, Java Secure Socket Extension, Solaris, and JAVAX are
trademarks or registered trademarks of Sun Microsystems, Inc. in the U.S. or other countries.
This product includes code licensed from RSA Data Security.
RELEASE NOTES AND DOCUMENT UPDATES
The hard copy and Compact Disc Read Only Memory (CD-ROM) versions of this document are revised only
at major releases and, therefore, may not always contain the latest product information. As needed,
Software Release Documents (SRDs), Hardware Release Documents (HRDs), Application Notes, Field
Service Bulletins (FSBs), and/or Document Maintenance Bulletins (DMBs) are provided between major
releases to describe any new information or document changes.
-
7/29/2019 009-2003-078 Alarm and Trouble Clearing.pdf
6/106
THIS PAGE INTENTIONALLY LEFT BLANK
PREFACE ONLINETM7000/9000/11000
Alarm and Trouble Clearing Manual
April 30, 2003 - Revision A
iv 009-2003-078
CIENA CONFIDENTIAL AND PROPRIETARY
CONTACTING CIENASYSTEM TECHNICAL FIELD RETURN
INFORMATION
NOTE: CIENAretains the sole right to determine if a problem is an emergency or a non-emergency.
Validate Requirements with Customer Support: Customer needs to contact CIENA Worldwide
Customer Services and Support to ensure that a replacement product is in fact required. CIENA
encourages all Customers to work with its technicians for a reasonable period to determine whether a
solution or workaround exists that does not require immediate component replacement. CIENA will not
accept any returns for warranty replacement without prior approval and adequate proof of purchase.
Warranty Replacement: Customer must furnish a receipt, purchase order, or other standard sales
document, or have the specific component serial number on file with CIENA Worldwide Customer Services
and Support to determine if a product is under warranty.
Warranty Claims: In the event of any warranty claim, Customer must
(a) Request a Return Material Authorization (RMA) number from CIENA by calling the appropriate
number listed above and (a) Comply with the terms and procedures described in the governing Purchase
and License Agreement(s).
Corporate Headquarters 410-694-5700 www.ciena.com
Customer Technical Support/
Warranty
In North America 1-800-CIENA24 (243-
6224)
E-mail:
In Europe 00800 843 52 322
or +44 181 843 52 322
E-mail: [email protected]
In Asia 0120-884-766
Sales and General Information 410-694-5700 E-mail: [email protected]
In North America 410-694-5700 E-mail: [email protected]
In Europe 44 207 389 7100 E-mail: [email protected]
In Asia +81-3-3248-4680 E-mail: [email protected]
Training and Documentation
Training 877-CIENA-TD (243-6283)
or 410-694-8120
E-mail: [email protected]
Documentation 877-CIENA-TD (243-6283)
or 410-694-8125
E-mail: [email protected]
-
7/29/2019 009-2003-078 Alarm and Trouble Clearing.pdf
7/106
ONLINETM7000/9000/11000 PREFACE
Alarm and Trouble Clearing Manual
April 30, 2003 - Revision A
009-2003-078 v
CIENA CONFIDENTIAL AND PROPRIETARY
Returning CIENA Product: Customer will receive an RMA number after contacting an
CIENA Worldwide Customer Services and Support representative.
To Prepare Product for Return to CIENACorporation
STEP 1: Package the product, using the original container, and return it to CIENA Corporation.
STEP 2: Write the RMA number on the outside of the box where it can be easily identified, and includeany additional information useful in determining the root cause of the failure.
STEP 3: Always remember to include Customers name and return address, with a completed returnaddress label always appreciated.
STEP 4: Ensure that the product you are shipping complies with all applicable Export Laws for and withinthe country you are shipping from and to. By shipping the product the customer agrees tocomply with all such laws and regulations.
STEP 5: Ship the product using a reputable and insured carrier.
LAB EVALUATION AND FIELD TRIALS
In accordance with trial-agreement escalation procedures, any problem encountered during laboratory
evaluations and field trials should be referred to the CIENA Corporation field trial coordinator.
-
7/29/2019 009-2003-078 Alarm and Trouble Clearing.pdf
8/106
THIS PAGE INTENTIONALLY LEFT BLANK
PREFACE ONLINETM7000/9000/11000
Alarm and Trouble Clearing Manual
April 30, 2003 - Revision A
vi 009-2003-078
CIENA CONFIDENTIAL AND PROPRIETARY
-
7/29/2019 009-2003-078 Alarm and Trouble Clearing.pdf
9/106
ONLINETM7000/9000/11000 TABLE OF CONTENTS
TOC
Alarm and Trouble Clearing Manual
April 30, 2003 - Revision A
009-2003-078 vii
CIENA CONFIDENTIAL AND PROPRIETARY
TABLE OF CONTENTS
PREFACE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .i
LIST OF FIGURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xv
LIST OF TABLES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xvii
CHAPTER 1 FAULT MANAGEMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1
Common Alarm Sources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1
Alarm Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1
Alarm Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1
Alarm Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2
Alarm Severity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-3
Alarm Audio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-4
Alarm Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-4
CIT Alarm Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-4
CLI Alarm Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-7
TL1 Alarm Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-8
To view alarm severities using TL1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8
To View All Alarms Using TL1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-9
Autonomous Alarm Messages in TL1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-9
To view user alarms using TL1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-9
CHAPTER 2 USER ALARMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-1
User Alarms Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-1
User Alarm Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-1
User Alarm Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-2
CHAPTER 3 ALARM CLEARING PROCEDURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-1
AIS (Alarm Indication Signal) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-1
Alarm Card Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-1
BER Test Running . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-1
Card Provisioning Mismatch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-2
Communications Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-2
Configuration Error . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-3
Cooling Fan Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-3
-
7/29/2019 009-2003-078 Alarm and Trouble Clearing.pdf
10/106
TABLE OF CONTENTS ONLINETM7000/9000/11000
TOC
Alarm and Trouble Clearing Manual
April 30, 2003 - Revision A
viii 009-2003-078
CIENA CONFIDENTIAL AND PROPRIETARY
DCC Link Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4
Diagnostics Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4
Diagnostics Failure Component Mgr_Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4
Diagnostics Failure FPGA Program Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-5
Diagnostics Failure Slot Mismatch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-5
Drive Mount Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-5
Duplicate SIDs in Subnet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-5
East Audit Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-5
East Default K Byte . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-6
East ENUT Table Mismatch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-6
East Improper APS Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-6
East Inconsistent APS Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-6East Interface Side Mismatch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-6
East Node ID Mismatch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7
East Protection Switch Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-7
East Ring Map Mismatch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-7
East Ring Map ID Mismatch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-7
East Squelch Table Mismatch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-7
EEPROM Data Error . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-8
EEPROM Problem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-8
Ethernet Link A Failure Ethernet Link B Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-8
Ethernet Switch Error . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-8
Ethernet Switch Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-9
Excessive Data Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-9
Excessive Input Power (Preamplifiers, Postamplifiers, PMM, or OLM) Excessive
Input Power Line (WCI CP) Excessive Input Power Trib (WCI CP) . . . . . . . . . . . . . . . . . .3-9
For Excessive Input Power Trib: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-9
For Excessive Input Power Line: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-10
For Excessive Input Power (Pre-amp, Post-amp, VGA): . . . . . . . . . . . . . . . . . . . . . . .3-10
External Reference Failed SYNC (A/B) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-11
External Reference Locked Out (SYNC A) External Reference Locked Out (SYNC B) . . .3-11
Fast Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-11
-
7/29/2019 009-2003-078 Alarm and Trouble Clearing.pdf
11/106
ONLINETM7000/9000/11000 TABLE OF CONTENTS
TOC
Alarm and Trouble Clearing Manual
April 30, 2003 - Revision A
009-2003-078 ix
CIENA CONFIDENTIAL AND PROPRIETARY
FPGA Failure, Line FPGA Failure, Trib FPGA Power Failure, Line
FPGA Power Failure, Trib . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-11
Forced Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-12
Forced Switch On Line Port Forced Switch On Trib Port . . . . . . . . . . . . . . . . . . . . . . . . . .3-12
Forced Sync Switch Active . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-12
Free Run . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-12
High Order Path AIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-12
High Order Path Remote Failure Indication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13
High Order Path Trace Identifier Mismatch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-13
High Order Path Unequipped . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-13
High Peak Voltage Violation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-13
High Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-14
Holdover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-14
HUB OSC Mismatch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-14
Invalid Data Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-15
Laser Bias Current Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-15
Laser Bias Current Failure, Line Laser Bias Current Failure, Trib . . . . . . . . . . . . . . . . . . . .3-15
Laser Wavelength Lock Failure, Line Laser Wavelength Lock Failure, Trib . . . . . . . . . . . .3-16
Line AIS (ADM, ESCON Mux, or STMX CP), 10GSMX Line AIS Line (WCI CP)
Line AIS Trib (WCI CP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-16
Line Remote Failure Indication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-16
Lockout of Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-17
Lockout of Protection On Line Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-17
Lockout of Protection On Trib Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-17
Lockout of Working . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-17
Lockout of Working On Line Port Lockout of Working On Trib Port . . . . . . . . . . . . . . . . . .3-17
Loopback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-18
Loss of Clock (ADM, or STMX CP) Loss of Clock Line (WCI CP)
Loss of Clock Trib (WCI CP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-18
Loss of Frame (ADM, ESCON Mux, GRDM, or STMX CP), 10GSMXLoss of Frame Line (WCI CP) Loss of Frame Trib (WCI CP) . . . . . . . . . . . . . . . . . . . . . . .3-18
Loss of Pointer (ADM, ESCON MUX, Data MUX, STMX) . . . . . . . . . . . . . . . . . . . . . . . . . .3-19
Loss of Signal (ADM I & II, ESCON MUX I & II, GRDM I & II, STMX, 10G SMX) . . . . . . . .3-19
Loss of Signal (OSC/OSH) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-19
Loss of Signal on Line Port (WCI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-20
-
7/29/2019 009-2003-078 Alarm and Trouble Clearing.pdf
12/106
TABLE OF CONTENTS ONLINETM7000/9000/11000
TOC
Alarm and Trouble Clearing Manual
April 30, 2003 - Revision A
x 009-2003-078
CIENA CONFIDENTIAL AND PROPRIETARY
Loss of Signal on Trib Port (WCI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-20
Loss of Signal (Line Circuit Pack) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-21
Loss of Signal Mux (CWDM-U) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-21
Loss of Signal Demux (CWDM-U) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-22
Loss of Signal OLM Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-22
Loss of Signal OSM Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-22
Loss of Signal OLM Node . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-23
Loss of SIgnal OSM Node . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-23
Loss of Signal PMM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-23
Loss of Signal Preamp (Preamp) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-24
Loss of Signal Postamp (Postamp) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-24
Loss of Signal PreVGA (VGA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-25Loss of Signal PostVGA (VGA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-25
Loss of Signal (SYNC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-26
Loss of Signal WPS - (WPS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-26
Loss Values Out of Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-26
Low Peak Voltage Violation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-27
Low System Resource Disk Space . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-27
Low System Resource Handle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-27
Low System Resource Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-27
Manual Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-28
Manual Switch On Line Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-28
Manual Switch On Trib Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-28
Memory Mismatch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-28
PSM Database is Down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-28
Multiplex Section AIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-28
Multiplex Section Remote Failure Indication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-29
Node in Hitless State . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-29
Node in Partially Turned Up State . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-29Node in Selective Restore . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-29
NVRAM Problem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-30
OCH AIS On Line Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-30
ODPR Protection Unavailable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-30
OOS Diagnostics Performed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-30
-
7/29/2019 009-2003-078 Alarm and Trouble Clearing.pdf
13/106
ONLINETM7000/9000/11000 TABLE OF CONTENTS
TOC
Alarm and Trouble Clearing Manual
April 30, 2003 - Revision A
009-2003-078 xi
CIENA CONFIDENTIAL AND PROPRIETARY
Optical Switch Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-31
OSC4080 Device Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-31
OSPR Protection Unavailable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-31
Out of Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-32
Path AIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-32
Path Remote Failure Indication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-33
Path Trace Mismatch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-33
Path Unequipped . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-33
Payload Mapping Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-33
Peer Communications Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-34
PMA Is Locked . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-34
Power ACO Card Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-35Power Entry Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-35
Power Management Problem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-35
Power Problem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-36
Processor Busy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-36
Program Memory Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-37
Program Memory Missing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-37
Protection Path Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-37
Provisioning Mismatch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-38
Receiver Failure Line Receiver Failure Trib . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-38
Reference Failed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-38
Reference Locked Out . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-39
Reference Out of Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-39
Regenerator Section Trace Identifier Mismatch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-39
Replaceable Unit Missing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-39
Replaceable Unit Problem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-40
Replaceable Unit Type Mismatch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-40
Section Trace Mismatch Section Trace Mismatch Line Section Trace Mismatch Trib . . . .3-40Shelf ID Mismatch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-41
Shelf Interconnect Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-41
Shelf Type Mismatch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-41
Signal Degrade BER (ADM, OSC, or STMX CP), 10GSMX
Signal Degrade BER Line (WCI CP) Signal Degrade BER Trib (WCI CP) . . . . . . . . . . . . .3-42
-
7/29/2019 009-2003-078 Alarm and Trouble Clearing.pdf
14/106
TABLE OF CONTENTS ONLINETM7000/9000/11000
TOC
Alarm and Trouble Clearing Manual
April 30, 2003 - Revision A
xii 009-2003-078
CIENA CONFIDENTIAL AND PROPRIETARY
Signal Fail BER (ADM, OSC, or STMX CP), 10GSMX
Signal Fail BER Line (WCI CP) Signal Fail BER Trib (WCI CP) . . . . . . . . . . . . . . . . . . . . .3-42
Signal Frequency Invalid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-42
Signal Squelched Line Signal Squelched Trib . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-42Signaling Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-43
Software Download Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-43
Software Environment Problem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-43
Wrong software loads on the current drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-43
Wrong software loads on the alternate drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-43
Activated on the wrong drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-44
Manual cold reboot required to upgrade FPGA version to most recent . . . . . . . . . . . .3-44
Load repository corrupt on current drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-44
Load repository corrupt on alternate drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-44
Unable to set software version in EEPROM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-44
Wrong software loads on the alternate flash region . . . . . . . . . . . . . . . . . . . . . . . . . . .3-44
Synchronization Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-45
Temperature Sensor Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-45
Temperature Out Of Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-46
Threshold Crossed LBC Line Threshold Crossed LBC Trib . . . . . . . . . . . . . . . . . . . . . . . .3-46
Threshold Crossed OPR (Extended OSC, Preamp, Postamp)
Threshold Crossed OPR Line, OPR Trib (WCI CP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-46
Threshold NM Crossed Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-47
Topology Discovering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-48
Topology Mismatch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-48
Trail Trace Mismatch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-50
Transmit Fail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-50
Transmitter Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-50
Transmitter Failure Post VGA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-51
Transmitter Failure Pre VGA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-51
Transmitter Failure Trib Transmitter Failure Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-51
Trib Optical Monitoring Not Supported . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-51
Underlying Resource Unavailable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-52
User Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-52
VOA Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-52
VOA Motor Missing Steps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-52
-
7/29/2019 009-2003-078 Alarm and Trouble Clearing.pdf
15/106
ONLINETM7000/9000/11000 TABLE OF CONTENTS
TOC
Alarm and Trouble Clearing Manual
April 30, 2003 - Revision A
009-2003-078 xiii
CIENA CONFIDENTIAL AND PROPRIETARY
VOA Motor Not Stepping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-52
VOA POT Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-53
Wavelength Management Unavailable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-53
West Audit Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-54
West Default K Byte . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-54
West ENUT Table Mismatch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-54
West Improper APS Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-55
West Inconsistent APS Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-55
West Interface Side Mismatch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-55
West Node ID Mismatch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-55
West Protection Switch Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-55
West Ring Map Mismatch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-56West Ring Map ID Mismatch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-56
West Squelch Table Mismatch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-56
APPENDIX A ALARM MESSAGE LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
INDEX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .I-1
-
7/29/2019 009-2003-078 Alarm and Trouble Clearing.pdf
16/106
THIS PAGE INTENTIONALLY LEFT BLANK
TABLE OF CONTENTS ONLINETM7000/9000/11000
TOC
Alarm and Trouble Clearing Manual
April 30, 2003 - Revision A
xiv 009-2003-078
CIENA CONFIDENTIAL AND PROPRIETARY
-
7/29/2019 009-2003-078 Alarm and Trouble Clearing.pdf
17/106
ONLINETM7000/9000/11000 LIST OF FIGURES
LOF
FIGURE # FIGURE NAME PAGE #
Alarm and Trouble Clearing Manual
April 30, 2003 - Revision A
009-2003-078 xv
CIENA CONFIDENTIAL AND PROPRIETARY
LIST OF FIGURES
Figure 1-1. Viewing Alarm Type Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
Figure 2-1. User Alarms Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
Figure 2-2. Enable/Disable User Alarm Outputs Dialog Box . . . . . . . . . . . . . . . . . . . . . . . 2-3
-
7/29/2019 009-2003-078 Alarm and Trouble Clearing.pdf
18/106
THIS PAGE INTENTIONALLY LEFT BLANK
LIST OF FIGURES ONLINETM7000/9000/11000
LOF
Alarm and Trouble Clearing Manual
April 30, 2003 - Revision A
xvi 009-2003-078
CIENA CONFIDENTIAL AND PROPRIETARY
-
7/29/2019 009-2003-078 Alarm and Trouble Clearing.pdf
19/106
ONLINETM7000/9000/11000 LIST OF TABLES
LOT
TABLE # TABLE NAME PAGE #
Alarm and Trouble Clearing Manual
April 30, 2003 - Revision A
009-2003-078 xvii
CIENA CONFIDENTIAL AND PROPRIETARY
LIST OF TABLES
Table 1-1. Interpreting Alarm Detail Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
Table 1-2. Alarm Severities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
Table 1-3. CIT Alarm Information Categories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5Table 3-1. Corrective Actions for the OSPR Protection Unavailable Alarm . . . . . . . . . . . 3-32
Table 3-2. Corrective actions for Wavelength Management Unavailable alarm . . . . . . . . 3-53
Table A-1. List of Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
-
7/29/2019 009-2003-078 Alarm and Trouble Clearing.pdf
20/106
THIS PAGE INTENTIONALLY LEFT BLANK
LIST OF TABLES ONLINETM7000/9000/11000
LOT
Alarm and Trouble Clearing Manual
April 30, 2003 - Revision A
xviii 009-2003-078
CIENA CONFIDENTIAL AND PROPRIETARY
-
7/29/2019 009-2003-078 Alarm and Trouble Clearing.pdf
21/106
ONLINETM7000/9000/11000 FAULT MANAGEMENT
1
Alarm and Trouble Clearing Manual
April 30, 2003 - Revision A
009-2003-078 1 - 1
CIENA CONFIDENTIAL AND PROPRIETARY
CHAPTER 1
FAULT MANAGEMENT
This chapter includes procedures and guidelines for using the various ONLINE 7000/9000/11000
Transport Platform command tools to prioritize alarm indications, filter alarms, and determine the cause(s)
of alarm(s) in the following sections:! Common Alarm Sources on page 1-1
! Alarm Characteristics on page 1-1
! Alarm Tools on page 1-4
COMMON ALARM SOURCES
Alarms typically occur as a result of the following conditions:
! Fiber breaks
! Equipment failure
! Software failure
! Operator error
When isolating the source of an alarm, start by examining if the cause of the alarm may be due to one of
the common errors prior to escalating your troubleshooting efforts. You can use the descriptions provided
in the alarm logs and reports to assist in isolating the source of alarms.
ALARM CHARACTERISTICS
This section explains the ONLINE system alarm components in the following sections:
! Alarm Conditions on page 1-1
! Alarm Detail on page 1-2
! Alarm Severity on page 1-3
ALARM CONDITIONS
Each alarm is categorized in a displayat the graphical craft interface terminal (CIT), command line
interface (CLI), Transaction Language 1 (TL1), or SNMP interfacesin accordance with the equipment
source from which the alarm is triggered. Although the fundamental range of alarm types is identical
regardless of the display platform, the manner in which the alarm types are identified differs in accordance
with the application you are using.
The CIT presents graphical alarm indicators, which are displayed for all equipment objects, in both the
hierarchical tree pane and the graphical pane. You can access information about a selected topology
object by using the View -> Alarms and Failures menu from the CIT main menu bar, to display an Alarm
and Failure List (Figure 1-1), in which to view the alarm type associated with the selected network object.
The illustration also demonstrates a typical display of the alarm type in a CLI message.
-
7/29/2019 009-2003-078 Alarm and Trouble Clearing.pdf
22/106
FAULT MANAGEMENT ONLINETM7000/9000/11000
1
Alarm and Trouble Clearing Manual
April 30, 2003 - Revision A
1 - 2 009-2003-078
CIENA CONFIDENTIAL AND PROPRIETARY
Figure 1-1. Viewing Alarm Type Information
ALARM DETAIL
At the CIT Alarm and Failure List window, you can view a wide range of information about specified
alarms in a graphical presentation. The same information is also available in the CLI and TL1 formats.
Table 1-1. Interpreting Alarm Detail Messages
Alarm Detail Description
New A black circle indicates a new alarm. If a new alarm is selected, the black
changes to white.
Affected Object The alarm location; for example "node57: Facilities: Trib: 3-2-E"
Time Day, date, and time the alarm was raised by the network element (NE). Time
stamp will be in GMT.
Severity Critical, major, minor, warning, or indeterminate
Probable Cause Most likely cause of the alarm, for example, "Loss of Signal."
Acknowledged If a checkbox in this column is filled in, the alarm has been acknowledged.
Operator The user ID of the operator who acknowledged the alarm.
CIT Alarm Type View
CLI Alarm Type View
-
7/29/2019 009-2003-078 Alarm and Trouble Clearing.pdf
23/106
ONLINETM7000/9000/11000 FAULT MANAGEMENT
1
Alarm and Trouble Clearing Manual
April 30, 2003 - Revision A
009-2003-078 1 - 3
CIENA CONFIDENTIAL AND PROPRIETARY
ALARM SEVERITY
Alarms are typically corrected in accordance with severity, type, and probable cause.
Alarms have the following severities:
! Critical (reported as CR in CLI, and *C in TL1)
!
Major (reported as MJ in CLI, and ** in TL1)! Minor (reported as MN in CLI, and *^ in TL1)
! Warning (reported as WN in CLI)
! Indeterminate
The alarm severity meanings are as described in Table 1-2.
The CIT provides color indicators throughout the interface to keep you apprised of current alarm conditions.
When enabled, the colors of the topology objects indicate the following conditions:
Type Equipment alarm, Processing error alarm, Environmental alarm, or
Communications alarm.
Notes Operator-entered supplemental information (usually, why an alarm was
acknowledged).
Additional Text Descriptive text, if any.
Table 1-2. Alarm Severities
Alarm Severity Definition
Critical Critical alarms indicate that a severe, service-affecting condition has occurred andthat immediate corrective action is imperative, regardless of the time of day or day
of the week.
Major Major alarms indicate hardware or software conditions causing a serious disruption
of service or the malfunctioning or failure of important circuits. These troubles
require the immediate attention and response of a craftsperson to restore or
maintain system capability. The urgency is less than in critical situations because
of a lesser immediate or impending effect on service or system performance.
Minor Minor alarms are used for troubles that do not have a serious effect on service to
customers or for troubles in circuits that are not essential to NE operation. For
example, a carrier line problem where transmission was switched to a protection
line is a minor alarm because it is non-service affecting.
Warning Warnings are alarm conditions that do not affect the functioning of the NE.
Indeterminate An indeterminate alarm indicates a problem of unknown severity (possibly a
multiple failure case) has been detected.
Table 1-1. Interpreting Alarm Detail Messages (Continued)
Alarm Detail Description
-
7/29/2019 009-2003-078 Alarm and Trouble Clearing.pdf
24/106
FAULT MANAGEMENT ONLINETM7000/9000/11000
1
Alarm and Trouble Clearing Manual
April 30, 2003 - Revision A
1 - 4 009-2003-078
CIENA CONFIDENTIAL AND PROPRIETARY
! GREEN = normal
! RED = critical alarm
! ORANGE = major alarm
! YELLOW = minor, warning, or indeterminate alarm
Alarm Audio
Alarm audio (also known as alarm enunciation), can be configured at the CIT to provide a sound indicator
as alarms are detected at the ONLINE NE. For more information, refer to To Use the Audible and Visible
alarm alert Tool at the CIT on page 1-6, and the OPTX Management Suite Graphical CIT User Guide
(OPN 310).
ALARM TOOLS
The alarm LEDs on the NE shelves and circuit packs (CPs) provide a first glance indication about
problems on the ONLINE system. To further examine details about the alarms, you can use the ONLINE
command interfaces to gather information to assist in identifying the source of the alarm situation.
This section describes the ONLINE system command applications that provide various methods for viewing,
modifying, and filtering alarms, in the following sections:
! CIT Alarm Tools on page 1-4
! CLI Alarm Tools on page 1-7
! TL1 Alarm Tools on page 1-8
NOTE: Do not begin removing CPs or connections until you have examined the alarm detail atthe CIT, or other ONLINE interface.
CIT Alarm ToolsThe CIT provides a graphical user interface (GUI) with which to view, delete, and monitor both ONLINE
system alarms and user alarms. System alarms are associated with various severities of malfunctioning
equipment, service, transmission paths, or software. User alarms are associated with possibly
unacceptable conditions that arise in the site environment in which the system is located.
NOTE: The description in this section does not contain screen captures of the CIT GUI alarmmanagement tools. To see the GUI components, please refer to the OPTX Graphical CITUser Guide (OPN 310)
The CIT GUI tools that are used for troubleshooting faults within the ONLINE network are accessed fromthe alarm menus (either from the CIT main menu bar or as popup menus derived from selected network
topology objects). The alarm menus provide options to generate alarm reports, acknowledge and
unacknowledge alarms, delete alarm(s), and view alarm details.
-
7/29/2019 009-2003-078 Alarm and Trouble Clearing.pdf
25/106
ONLINETM7000/9000/11000 FAULT MANAGEMENT
1
Alarm and Trouble Clearing Manual
April 30, 2003 - Revision A
009-2003-078 1 - 5
CIENA CONFIDENTIAL AND PROPRIETARY
TOVIEWALLALARMSATTHE CIT
Use the Fault-View Alarms and Failures menu to present the Subnetwork Alarm and Failure List
window. The information in this window describes alarm associations to NEs, time, severity, causes, and
actions performed in response to the alarm indications (Table 1-3).
TOVIEWSEVERITY-SPECIFICALARMSATTHE CITThe columns and column entries in the Alarm and Failure List window can be sorted to customize the
arrangement of the columns. You can use the single-sorting mechanism to organize alarms by criticality (as
well as by other criteria). You can also show, hide, and reorder the alarm columns to customize the view in
accordance with your filtering preferences.
To find out how to use the Select Sort Columns and Column Options menu at the CIT, see the OPTX
Graphical CIT User Guide (OPN 310).
Table 1-3. CIT Alarm Information Categories
Column Label Description
Affected Identifier of the ONLINE NE affected by the alarm.
Time Hour, minute, and second of the alarm occurrence.
Severity Level of severity as either critical (red), major (orange),
minor (yellow), warning (yellow), or indeterminate
(yellow).
Probable Cause Condition detected by the ONLINE system that
triggered the alarm.
Acknowledge Checkbox that indicates whether or not the alarm has
been acknowledged. If checked, the alarm has been
acknowledged. If not checked, the alarm has not been
acknowledged.
Operator User ID of the operator who acknowledged the alarm.
Type Alarm type, as either equipment, processing error,
environmental, or communications.
Notes Supplemental information provided by the operator,
which may include information about why the alarm
was acknowledged, or contain plan detail for rectifying
the alarm condition.
Addition Additional text area in which to provide information
about the alarm.
Cleared Checkbox that indicates that the alarm has been fixed
and/or is no longer considered an alarm condition.
When checked, the alarm is cleared. When not
checked, the alarm is not yet cleared. Cleared alarms
are not removed from the alarm list until deleted.
-
7/29/2019 009-2003-078 Alarm and Trouble Clearing.pdf
26/106
FAULT MANAGEMENT ONLINETM7000/9000/11000
1
Alarm and Trouble Clearing Manual
April 30, 2003 - Revision A
1 - 6 009-2003-078
CIENA CONFIDENTIAL AND PROPRIETARY
TODELETEALARMSATTHE CIT
At the CIT, use the tools provided in the Alarm Retirement Setup dialog box, or the Fault-Delete Cleared
Alarms menu, or the Alarm and Failure Report view to remove specified alarms.
! The Alarm Retirement Setup dialog box allows you to instruct the ONLINE system to
automatically delete alarms that are cleared and acknowledged.
! Using the Fault-Delete menu enables you to select and confirm removal of specified alarms.
! Right-clicking on a selected row in the Alarm and Failure Report view presents a popup
menu from which you can delete selected alarms.
To view the CIT GUI elements associated with these tasks, please refer to the OPTX Graphical CIT User
Guide (OPN 310).
TOVIEWTHEALARMHISTORYLOGATTHE CIT
Use the alarm report functions in the CIT to view alarm history logs. The various report types are accessed
by clicking anywhere on the heading row of the Subnetwork Alarm and Failure List, or by using the Fault
menu from the CIT main menu. Alarm reports are categorized as follows:
! Custom Alarm Report (HTML)
Use the Custom Alarm Report (HTML) option if you want to view filtered and/or sorted alarm detail in a
web browser window. The view presented in this custom report is based on your customization of the
alarm list details (as described in To view severity-specific alarms at the CIT on page 1-5).
! Custom Alarm Report (CSV)
Use the Custom Alarm Report (CSV) option if you want to write the filtered and/or sorted alarm report
as an Excel file to a specified location.
! Complete Alarm Report (HTML)
Use the Complete Alarm Report (HTML) option if you want to view all, unfiltered alarm detail in a web
browser window. The view presented in this custom report is based on your customization of the alarm
list details.
! Complete Alarm Report (CSV)Use the Complete Alarm Report (CSV) option if you want to write all alarm detail reported to the CIT as
an Excel file to a specified location.
TO USETHE AUDIBLEAND VISIBLEALARMALERT TOOLATTHE CIT
At the CIT, present the Audible and Visible Alerts dialog box; available from Fault-Alerts option from the
CIT main menu. This dialog box enables activation and deactivation of the audible and visible alerts at the
local workstation. You can filter the alerts by specifying the severity level to be associated with the alerts,
and whether or not you want to view alerts only, hear sound only, or use both alert mechanisms.
Activating visible result in display of a message box that contains information associated with the alarm.
To view the CIT GUI elements associated with these tasks, please refer to the OPTX Graphical CIT User
Guide (OPN 310).
-
7/29/2019 009-2003-078 Alarm and Trouble Clearing.pdf
27/106
ONLINETM7000/9000/11000 FAULT MANAGEMENT
1
Alarm and Trouble Clearing Manual
April 30, 2003 - Revision A
009-2003-078 1 - 7
CIENA CONFIDENTIAL AND PROPRIETARY
CLI Alarm Tools
The CLI commands that are used for troubleshooting faults within the ONLINE network are show alarm
and show log.
NOTE: The CLI also includes the unlock alarm command, which is used only to take the alarmcard out of the administrative service state.
TOVIEWALLALARMSUSINGTHE CLI
Use the show alarm command to view active alarms on the NE. This command is resource level sensitive;
meaning the alarm information displayed is limited in scope to the level set by the resource command.
Example: View unfiltered list of all current alarms
MyNode> show alarm
Alarms for node: MyNode
Identifier Status Type Date Time-UTC Probable Cause
----------------------------------------------------------------------
OT-E WN comm 08/09/00 17:47:36 thresholdCrossedOPR
OT-W WN comm 08/09/00 17:47:13 thresholdCrossedOPR
OCH-6-1-W CR comm 08/09/00 17:48:33 lossOfFrameTrib
OCH-6-1-W CR comm 08/09/00 17:49:24 lossOfFrameLine
OCH-6-1-W WN comm 08/09/00 17:47:05 thresholdCrossedOPRLine
OCH-8-3-W WN comm 08/09/00 17:47:21 thresholdCrossedOPRTrib
OCH-3-2-E CR comm 08/09/00 17:48:45 lossOfFrameLine
OCH-3-2-E CR comm 08/09/00 17:48:45 aISTrib
TOVIEWSEVERITY-SPECIFICALARMSUSINGTHE CLI
Example: An instruction to the NE to issue a list of all critical alarms.
MyNode> show alarm critical
Alarms for node: MyNode
Identifier Status Type Date Time-UTC Probable Cause
-------------------------------------------------------------------
OCH-6-1-W CR comm 08/09/00 17:48:33 lossOfFrameTrib
OCH-6-1-W CR comm 08/09/00 17:49:24 lossOfFrameLine
OCH-3-2-E CR comm 08/09/00 17:48:45 lossOfFrameLine
OCH-3-2-E CR comm 08/09/00 17:48:45 aISTrib
MyNode>
-
7/29/2019 009-2003-078 Alarm and Trouble Clearing.pdf
28/106
FAULT MANAGEMENT ONLINETM7000/9000/11000
1
Alarm and Trouble Clearing Manual
April 30, 2003 - Revision A
1 - 8 009-2003-078
CIENA CONFIDENTIAL AND PROPRIETARY
TOVIEWTHEALARMHISTORYLOGUSINGTHE CLI
Use the show log command to view alarm log entries for a specified NE. This command is resource level
sensitive; meaning the alarm information displayed is limited in scope to the level set by the resource
command.
Example: Viewing an alarm log filtered to show alarm severity as well as time period.
MyNode> show log critical 2000/8/9/17/45 2000/8/9/17/50
Alarm Log for node: MyNode
No. Date Time-UTC Identifier Status Type Probable Cause
----------------------------------------------------------------------
1 08/09/00 17:46:11 rtp_node2 CR proccess powerManagementProblem
2 08/09/00 17:47:33 OCH-8-3-W CR comm lossOfSignalLine
3 08/09/00 17:47:32 OCH-3-2-E CR comm lossOfSignalLine
4 08/09/00 17:47:32 OCH-3-2-E CR comm lossOfSignalTrib
5 08/09/00 17:48:28 rtp_node2 CR proccess powerManagementProblem
6 08/09/00 17:48:37 OT-E CR comm lossOfSignalPostamp
7 08/09/00 17:48:42 OCH-3-2-E CR comm lossOfFrameTrib
8 08/09/00 17:48:41 OCH-8-3-W CR comm lossOfFrameLine
9 08/09/00 17:47:04 OCH-6-1-W CR comm lossOfSignalTrib10 08/09/00 17:47:04 OCH-6-1-W CR comm lossOfSignalLine
11 08/09/00 17:48:33 OCH-6-1-W CR comm lossOfFrameTrib
12 08/09/00 17:48:38 OCH-8-3-W CR comm lossOfFrameTrib
13 08/09/00 17:48:52 OCH-6-1-W CR comm lossOfFrameLine
14 08/09/00 17:49:24 OCH-6-1-W CR comm lossOfFrameLine
15 08/09/00 17:48:45 OCH-3-2-E CR comm lossOfFrameLine
16 08/09/00 17:48:45 OCH-3-2-E CR comm aISTrib
17 08/09/00 17:49:11 OCH-6-1-W CR comm signalFailBER
18 08/09/00 17:47:20 OCH-8-3-W CR comm lossOfSignalTrib
MyNode>
TL1 ALARM TOOLS
To view alarm severities using TL1
! *C = Critical
! ** = Major
! *^ = Minor
! A^ = Clear
The almcde in TL1 indicates the severity of the autonomous messages. Where multiple alarms are reported
in the same message, the displayed alarm code is the most severe.
-
7/29/2019 009-2003-078 Alarm and Trouble Clearing.pdf
29/106
-
7/29/2019 009-2003-078 Alarm and Trouble Clearing.pdf
30/106
THIS PAGE INTENTIONALLY LEFT BLANK
FAULT MANAGEMENT ONLINETM7000/9000/11000
1
Alarm and Trouble Clearing Manual
April 30, 2003 - Revision A
1 - 10 009-2003-078
CIENA CONFIDENTIAL AND PROPRIETARY
-
7/29/2019 009-2003-078 Alarm and Trouble Clearing.pdf
31/106
ONLINETM7000/9000/11000 USER ALARMS
2
Alarm and Trouble Clearing Manual
April 30, 2003 - Revision A
009-2003-078 2 - 1
CIENA CONFIDENTIAL AND PROPRIETARY
CHAPTER 2
USER ALARMS
This chapter describes the User Alarms feature, in the following sections:
! User Alarms Description on page 2-1
! User Alarm Dialog Box on page 2-1
! User Alarm Outputs on page 2-2
USER ALARMS DESCRIPTION
The Alarm I/O card has detectors to receive inputs from customer equipment that raise user alarms.
Besides the systems pre-defined probable causes, there are eight user alarm probable causes
(User Alarm 1 through User Alarm 8) in systems with a Vertical 19" (19V) or Vertical 23" (23V) main shelf,
and 12 User Alarm Probable Causes (User Alarm 1 through User Alarm 12) in systems with a 23" (23) main
shelf.
The user alarms represent alarms raised outside of the network element (NE), for example a fire alarm,
power surge, flooding, air conditioning or fan failure, or similar condition.
Since these user alarms may severely affect the proper working condition of the system, the detected failure
is passed to the NE, and can be raised as a system failure alarm. Users can decide whether to raise a user
alarm against the NE or not by assigning the alarm severity value as follows:
! If the severity value is notReported, the NEs alarm LEDs will not be lit, the user alarm is not
counted, and the user alarm event will be not sent to CIT/EMS. However, the user alarm will
be added to the NEs current problem list.
! If the severity value is warning, the NEs alarm LEDs will be not lit, the user alarm is not
counted; but the user alarm event will be sent to CIT/EMS, and it will be added to the NEs
current problem list.
! If the severity value is minor or higher, the NEs alarm LEDs will be lit, the user alarm is
counted, the user alarm event will be sent to CIT/NM, and it will be added to the NEs currentproblem list.
USER ALARM DIALOG BOX
The User Alarm dialog box is used for defining the additional text associated with each user alarm.
A meaningful description should be entered for each of the user alarms.
STEP 1: In the CIT select an NE object from the tree and select FaultUser Alarms.
The UserAlarmsDialog box appears, as shown in Figure 2-1. This dialog box shows the listof User Alarms and the corresponding Additional Text.
STEP 2: To edit a user alarm, click in the Additional Text field and enter the description.
STEP 3: When you are have completed your entries, click OK.
-
7/29/2019 009-2003-078 Alarm and Trouble Clearing.pdf
32/106
USER ALARMS ONLINETM7000/9000/11000
2
Alarm and Trouble Clearing Manual
April 30, 2003 - Revision A
2 - 2 009-2003-078
CIENA CONFIDENTIAL AND PROPRIETARY
Figure 2-1. User Alarms Dialog Box
USER ALARM OUTPUTS
This dialog box is used to operate the remote control (contact closures) for the audible and visible outputs.
Select FaultUser Alarm Outputs. The Enable/Disable User Alarm Outputs dialog box appears, as
shown in Figure 2-2. A check in the Enabled column indicates that a particular alarms outputs are enabled.
If there is no check, the alarms outputs are disabled.
To enable or disable a User Alarms outputs, check or uncheck the checkbox in the Enabled field for that
alarm. When you are done enabling or disabling the User Alarms outputs, click OK.
-
7/29/2019 009-2003-078 Alarm and Trouble Clearing.pdf
33/106
ONLINETM7000/9000/11000 USER ALARMS
2
Alarm and Trouble Clearing Manual
April 30, 2003 - Revision A
009-2003-078 2 - 3
CIENA CONFIDENTIAL AND PROPRIETARY
Figure 2-2. Enable/Disable User Alarm Outputs Dialog Box
-
7/29/2019 009-2003-078 Alarm and Trouble Clearing.pdf
34/106
THIS PAGE INTENTIONALLY LEFT BLANK
USER ALARMS ONLINETM7000/9000/11000
2
Alarm and Trouble Clearing Manual
April 30, 2003 - Revision A
2 - 4 009-2003-078
CIENA CONFIDENTIAL AND PROPRIETARY
-
7/29/2019 009-2003-078 Alarm and Trouble Clearing.pdf
35/106
ONLINETM7000/9000/11000 ALARM CLEARING PROCEDURES
3
Alarm and Trouble Clearing Manual
April 30, 2003 - Revision A
009-2003-078 3 - 1
CIENA CONFIDENTIAL AND PROPRIETARY
CHAPTER 3
ALARM CLEARING PROCEDURES
These procedures identify the actions needed to correct the alarm conditions. Before replacing any circuit
pack (CP), be sure to check the connections and label them clearly, so that they can be reconnected in the
proper positions easily.Communications alarms caused by equipment failure within the node should be accompanied by related
equipment alarms. If so, correcting the equipment problem should resolve both the equipment and the
communications alarms. Therefore, deal with equipment alarms first.
Communications alarms without equipment alarms can indicate a problem elsewhere in the network
(outside the node), or a problem with one or more of the fibers in the node.
NOTE: Alarms are listed alphabetically in this section by Probable Cause.
AIS (ALARM INDICATION SIGNAL)Explanation The Sync CP receives a clock source input directly from BITS or indirectly through a daisy
chain configuration. This alarm indicates that there is a fault condition upstream for the clock source of
the Sync CP.
Affected Object External Sync reference object
Alarm Type Communications
Default Severity Major
Recommended Action A possible fault condition could be an LOS or OOF alarm in the BITS source
itself, or one of the Sync CPs in the middle.
ALARM CARD FAILURE
Explanation Indicates that the alarm card is either missing or has suffered a hardware failure.
Affected Object Shelf
Alarm Type Environmental
Default Severity Minor
Recommended Action If the Alarm Card is missing, install it. If the Alarm Card is present, reset it by
removing and reinserting it. If this does not clear the alarm, replace the alarm
card.
BER TEST RUNNING
Explanation This alarm is raised when the BER test starts and cleared when the BER test ends.
Affected Object GRDM Circuit Pack
Alarm Type Equipment Alarm
Default Severity Warning
Recommended Action None.
-
7/29/2019 009-2003-078 Alarm and Trouble Clearing.pdf
36/106
ALARM CLEARING PROCEDURES ONLINETM7000/9000/11000
3
Alarm and Trouble Clearing Manual
April 30, 2003 - Revision A
3 - 2 009-2003-078
CIENA CONFIDENTIAL AND PROPRIETARY
CARD PROVISIONING MISMATCH
Explanation Provisioning in the circuit pack does not match the information stored in the PEM.
Affected Object Circuit Pack
Alarm Type Equipment Alarm
Default Severity MinorRecommended Action Reboot the circuit pack using the Warm Reboot With Provisioning Re sync
option. If the alarm is raised again once the circuit pack recovers from the
warm reboot, then contact CIENA Worldwide Customer Services and
Support.
COMMUNICATIONS FAILURE
Explanation This alarm will be raised by OPTX Management Suite GCIT or OPTX NM when a node
is not reachable.
The additional text is: Primary/GNE/ww.xx.yy.zz unreachable
Affected Object GNEAlarm Type Communication
Default Severity Major
Recommended Action Verify if the OPTX NM Client or OPTX GCIT has valid data communications
connectivity to the subnetwork by pinging the GNE or establishing a
connection via an alternate interface such as the Command Line Interface
(CLI) or TL1. If connectivity is valid, the PEM at the GNE may have rebooted,
so allow up to 5 minutes for the GNE to recover and for communications to
restore. If this alarm persists, contact CIENA Worldwide Customer Services
and Support.
Explanation This alarm will be raised by OPTX Management Suite GCIT or OPTX NM when a node
is not reachable
The additional text is: Network element (id=x) is unreachable
Affected Object NE
Alarm Type Communication
Default Severity Critical
Recommended Action If the GNE is affected, then see the recommended actions above. If a remote
NE is affected, there may be various reasons for the communications loss,
including a PEM reboot, line fiber break, or other connectivity issues which
may be denoted by additional alarms. If this alarm persists for more than 5
minutes, then contact CIENA Worldwide Customer Services and Support.
-
7/29/2019 009-2003-078 Alarm and Trouble Clearing.pdf
37/106
ONLINETM7000/9000/11000 ALARM CLEARING PROCEDURES
3
Alarm and Trouble Clearing Manual
April 30, 2003 - Revision A
009-2003-078 3 - 3
CIENA CONFIDENTIAL AND PROPRIETARY
Explanation The PEM cannot communicate to the affected circuit pack over either Ethernet link.
Affected Object CP
Alarm Type Equipment
Default Severity Minor
Recommended Action This alarm may denote that the affected circuit pack is rebooting and will
clear when the circuit pack recovers. If the alarm persists, then there may bea failure on the the circuit pack requiring it to be replaced. Typically, the
affected circuit pack should not be reseated as it may still be functioning
properly but will fail to recover to an operational state if the communications
failure condition persists. If the CP LED is solid red, replace the circuit pack.
Otherwise, contact CIENA Worldwide Customer Services and Support.
If this alarm is raised against multiple circuit packs, it is often due to some
other condition that will typically be denoted by one or more additional alarms
such as Ethernet Switch Failure, Shelf Interconnect Failure, or Node in
Hitless State. Investigate the other alarms and contact CIENA Worldwide
Customer Services and Support as needed.
CONFIGURATION ERROR
Explanation This alarm is raised when the NE restarts with a new database (i.e. after restoring an NE
from a backup file or performing hitless database recovery) and there is a provisioned circuit with
unprovisioned supporting equipment.
The additional text is: Equipment not available to support circuit
Affected Object Network element
Alarm Type Environmental
Default Severity Critical
Recommended Action Provision the equipment that supports the existing circuit.
COOLING FAN FAILURE
Explanation This alarm indicates that the cooling fan is not functioning. The lack of a functioning
cooling fan can cause a High Temperature alarm in the CPs, which has a default priority of Critical.
For the 23" shelf (23") the default severity is major if fans A and B both fail.
Affected Object Shelf
Alarm Type Environmental
Default Severity Minor/Major
Recommended Action Check the cooling fan. If it is not working, remove the unit and replace it.
-
7/29/2019 009-2003-078 Alarm and Trouble Clearing.pdf
38/106
ALARM CLEARING PROCEDURES ONLINETM7000/9000/11000
3
Alarm and Trouble Clearing Manual
April 30, 2003 - Revision A
3 - 4 009-2003-078
CIENA CONFIDENTIAL AND PROPRIETARY
DCC LINK FAILURE
Explanation This alarm will be raised if DCC is configured but there is a problem with the
communication.
Affected Object ADM Circuit Pack
Alarm Type ProcessingDefault Severity Major
Recommended Action Verify DCC is configured on the remote circuit pack and the circuit pack is
up. If the remote circuit pack is provisioned correctly with DCC, then verify
the fibers are physically connected properly. Also, ensure the fibers are fully
seated in their respective bulkhead connectors and have proper signal.
DIAGNOSTICS FAILURE
Explanation Diagnostics are run in the background by the system software once a circuit pack
recovers from a restart. It then runs periodically every 15 minutes. Diagnostics can also be manually
invoked by the user. A failure of a diagnostic test results in Diagnostics Failure alarm and will clear if the
failing diagnostic subsequently passes.
Affected Object Circuit pack
Alarm Type Equipment
Default Severity Warning
DIAGNOSTICS FAILURE COMPONENT MGR_TEST
Explanation This alarm is raised when the microboot file version in the circuit pack is incorrect.
Affected Object Circuit pack
Alarm Type Equipment
Default Severity Warning
Recommended Action Warm reboot the circuit pack. If the alarm does not clear, then call CIENA
Worldwide Customer Services and Support.
diagnosticsFailureEEPromTest diagnosticsFailureDeviceEEProm
diagnosticsFailureSpiBusTest diagnosticsFailureDeviceSwitch
diagnosticsFailureHDLCTests diagnosticsFailureDeviceEDFA
diagnosticsFailureEthernetCpm0 diagnosticsFailureDeviceGrdmPhy
diagnosticsFailureEthernetCpm1 diagnosticsFailureDeviceLM81
diagnosticsFailure48VbusA diagnosticsFailureDeviceLEDdiagnosticsFailure48VbusB diagnosticsFailureDevice4080
diagnosticsFailureDevice3270_3110 diagnosticsFailureDeviceI2c
diagnosticsFailureDeviceParallel diagnosticsFailureDeviceCommonLed
diagnosticsFailureDeviceDio diagnosticsFailureADCLoopbackTest
diagnosticsFailureOscMRV diagnosticsFailureDeviceGrdmYukon
diagnosticsFailureDeviceSigFpga diagnosticsFailureDeviceDACad8412
diagnosticsFailureDeviceGrdmEpld diagnosticsFailureDeviceADClm12458
diagnosticsFailureDevicePM5347
-
7/29/2019 009-2003-078 Alarm and Trouble Clearing.pdf
39/106
ONLINETM7000/9000/11000 ALARM CLEARING PROCEDURES
3
Alarm and Trouble Clearing Manual
April 30, 2003 - Revision A
009-2003-078 3 - 5
CIENA CONFIDENTIAL AND PROPRIETARY
DIAGNOSTICS FAILURE FPGA PROGRAM FAILURE
Explanation This alarm is raised when there has been a failure to program the FPGA.
Affected Object Circuit pack
Alarm Type Equipment
Default Severity MajorRecommended Action Cold reboot the circuit pack to make a second attempt to program the FPGA.
If the alarm persists after the cold reboot, then call CIENA Worldwide
Customer Services and Support to obtain a Return Material Authorization
(RMA) for the circuit pack.
DIAGNOSTICS FAILURE SLOT MISMATCH
Explanation This alarm is raised when the slot ID obtained from the backplane does not match the
provisioned slot of the circuit pack.
Affected Object Circuit pack/Chassis Backplane
Alarm Type Equipment
Default Severity Critical
Recommended Action Call CIENA Worldwide Customer Services and Support.
DRIVE MOUNT FAILURE
Explanation This alarm indicates that the PEM is not able to mount the C: drive or D: drive of the PSM.
Affected Object PSM circuit pack
Alarm Type Equipment
Default Severity Minor
Recommended Action Reboot or replace the PSM circuit pack.
DUPLICATE SIDS IN SUBNETExplanation The user set the SID table entry, and entered duplicate SID values for two different
nodes.
Affected Object Network element
Alarm Type Processing error
Default Severity Major
Recommended Action Correct the SID table entry.
EAST AUDIT FAILURE
Explanation This alarm is raised when the audit engine in the ADM circuit pack is not able to
communicate with its east neighbor.
Affected Object ADM Circuit Pack
Alarm Type Processing
Default Severity Major
Recommended Action Verify continuity to the east neighbor.
-
7/29/2019 009-2003-078 Alarm and Trouble Clearing.pdf
40/106
ALARM CLEARING PROCEDURES ONLINETM7000/9000/11000
3
Alarm and Trouble Clearing Manual
April 30, 2003 - Revision A
3 - 6 009-2003-078
CIENA CONFIDENTIAL AND PROPRIETARY
EAST DEFAULT K BYTE
Explanation This alarm is raised when the east side of the ADM pair has received a default K byte in
three consecutive frames. A default K byte is an indication of a misconfigured node.
Affected Object ADM Circuit Pack
Alarm Type CommunicationDefault Severity Major
Recommended Action Verify continuity and node protection provisioning and make adjustments as
necessary to clear the alarm.
EAST ENUT TABLE MISMATCH
Explanation This alarm is raised when the audit engine in the ADM circuit pack detects a mismatch
of the ENUT table with the east neighbor.
Affected Object ADM Circuit Pack
Alarm Type Processing
Default Severity Major
Recommended Action Compare and verify the ENUT tables on both nodes.
EAST IMPROPER APS CODE
Explanation This alarm is raised when the east side of the ADM pair has received APS code which is
not consistent with the state of the receiving node.
Affected Object ADM Circuit Pack
Alarm Type Communication
Default Severity Major
Recommended Action
EAST INCONSISTENT APS CODEExplanation This alarm is raised when the east side of the ADM pair is observing that out of 12 frames,
no three frames contain identical APS code.
Affected Object ADM Circuit Pack
Alarm Type Communication
Default Severity Major
Recommended Action
EAST INTERFACE SIDE MISMATCH
Explanation This alarm is raised when the audit engine of the ADM circuit pack is provisioned to the
same interfaceSide as the east neighbors.Affected Object ADM Circuit Pack
Alarm Type Processing
Default Severity Major
Recommended Action When provisioning the SONET BLSR protection, the user must identify the
west and east side of the ADM pair of ports involved in the protection. Verify
the west and east side is provisioned correctly on both nodes and verify fiber
connections.
-
7/29/2019 009-2003-078 Alarm and Trouble Clearing.pdf
41/106
ONLINETM7000/9000/11000 ALARM CLEARING PROCEDURES
3
Alarm and Trouble Clearing Manual
April 30, 2003 - Revision A
009-2003-078 3 - 7
CIENA CONFIDENTIAL AND PROPRIETARY
EAST NODE ID MISMATCH
Explanation This alarm is raised when the east side of the ADM pair has received three consecutive
and identical frames that contain a source node ID that does not match any entry in the ring map.
Affected Object ADM Circuit Pack
Alarm Type CommunicationDefault Severity Major
Recommended Action Verify the node ID and ring map provisioning to resolve any inconsistencies.
EAST PROTECTION SWITCH FAILURE
Explanation This alarm is raised by the BLSR switch engine when an attempt to switch had failed.
Affected Object ADM Circuit Pack
Alarm Type Communication
Default Severity Major
Recommended Action This alarm will clear when the switching condition does not exist any longer
or the switching was completed.
EAST RING MAP MISMATCH
Explanation This alarm is raised when the audit engine of the ADM circuit pack detects its ring map
is different from its east neighbors.
Affected Object ADM Circuit Pack
Alarm Type Processing
Default Severity Major
Recommended Action Compare the local and east neighbors ring map to identify any
inconsistencies.
EAST RING MAP ID MISMATCHExplanation This alarm is raised when the audit engine of the ADM circuit pack detects an ID from its
east neighbor which does not match the ring map.
Affected Object ADM Circuit Pack
Alarm Type Processing
Default Severity Major
Recommended Action The additional text field for the alarm will indicated the neighbors ring map
ID. Use this information to correct the ring map inconsistencies.
EAST SQUELCH TABLE MISMATCH
Explanation This alarm is raised by the audit engine of the ADM circuit pack when its squelch tableid different from its east neighbors.
Affected Object ADM Circuit Pack
Alarm Type Processing
Default Severity Major
Recommended Action Verify squelch tables from the local node and east neighbor. The additional
text field associated with the alarm will indicate the first timeslot where the
mismatches start.
-
7/29/2019 009-2003-078 Alarm and Trouble Clearing.pdf
42/106
ALARM CLEARING PROCEDURES ONLINETM7000/9000/11000
3
Alarm and Trouble Clearing Manual
April 30, 2003 - Revision A
3 - 8 009-2003-078
CIENA CONFIDENTIAL AND PROPRIETARY
EEPROM DATA ERROR
Explanation Indicates an error with the EEPROM in the circuit pack.
Affected Object CWDM-U, OLM, OSM, PMM
Alarm Type Equipment
Default Severity CriticalRecommended Action Call CIENA Worldwide Customer Services and Support for assistance.
EEPROM PROBLEM
Explanation Raised by an internal audit when some EEPROM fields are invalid. Additional text will
indicate the invalid field. This alarm is not service affecting.
Affected Object Network Element
Alarm Type Equipment
Default Severity Minor
Recommended Action Call CIENA Worldwide Customer Services and Support for assistance.
ETHERNET LINK A FAILURE
ETHERNET LINK B FAILURE
Explanation These alarms are raised when one of the OSC or COM cards