1
StruxureWare™ Building Operation
2012.05.01 1.1 to 1.3
Schneider Electric 2- Buildings – Roadmap V 3.0 July 2012
Released: Q4 2011
G
Technology Highlights• Easy to Connect
• TAC I/A Series – MNL Support• Easy to Migrate
• NETWORK 8000 – Phase 1 (of 2)• Easy to Access
• Web connectivity using WebStation• Easy access to Automation Server or
Enterprise Server• Includes support for graphics, trends,
alarms, reports and more• Easy to Engineer
• Spreadsheet: Mass create/Mass change• Certified BACnet Compliance
• Automation Server BTL B-BC listed w/ WSPCertWeb Access
StruxureWare Building Operation v1.1
3Schneider Electric - Buildings Business – Company Confidential
WebStation
●Direct access to the Automation Server and Enterprise Server via a web browser
● Supported: Internet Explorer 8 (32-bit) & Firefox 3.6 (32-bit)● No additional software or local installation at browser
machine needed; Java pre-requisite
●Delegate responsibilities and perform everyday operations
● View graphics, trends, schedules, and reports● Change values (e.g. temperature setpoints)● Update schedules● Manage alarms● Manage users● View customized workspaces as configured for WorkStation
●Secure access● WebStation requires user name and password for log on
4Schneider Electric - Buildings Business – Company Confidential
MNL controller support●Native support for MNL controllers using the AS-L Automation Server
● Wire, configure, and program the MNL controllers as a native part of the StruxureWare Building Operation system – not as third party devices
● New “greenfield” MNL controllers natively supported
●Requires use of WorkPlace Tech Editor software● Software included with WorkStation v1.1 installation● License included with Editor Pack (script and function block programming)● Pre-requisite: MS Visio 2003 or MS Visio 2007 SP2
●Existing MNL controller supported – i.e. integration to an existing site● Existing .VSD files can be imported into the Automation Server; no conversion service● .VSD file is hosted in the Automation Server; no need to remotely manage files per
project
●Minimum versions for compatibility:● Standard MNL controllers: v4.1● MNL-800: v2.0
5Schneider Electric - Buildings Business – Company Confidential
BTL and WSPCert BACnet® certifications
●AS-B has successfully passed two independent BACnet testing centers’ requirements
●With v1.1, the Automation Server has been certified by:
● BACnet Testing Laboratories (BTL) as a BACnet Building Controller (B-BC)
● WSPCert
●StruxureWare Building Operation’s BACnet MS/TP (b3 controllers) are BTL certified as BACnet Advanced Application
Controllers (B-AAC)
6Schneider Electric - Buildings Business – Company Confidential
NETWORK 8000 backward compatibility (Phase 1)
● Support for ASD (Application Specific Device) field bus directly under an Automation Server
● Global Control Module (GCM) controller database conversion service available
● Convert GCM database to .XML file for Automation Server import
● Receive report for estimate of what is convertible and price
● Approx 98% of content successfully convertible
● Minimum NETWORK 8000 GCM controller version required for database conversion: v4.2M
OD
BU
S
StruxureWare Building Operation
WorkStation
StruxureWare
Building Operation WebStation
Schneider Electric 7- Buildings – Roadmap– August 2011 COMPANY CONFIDENTIAL
Conversion candidates in Version 1.1
●NETWORK 8000 systems with ASD field bus under a GCM● Maximum 10 GCMs in the system● Site is willing to create new graphics● If LCM field bus is present, must wait for Phase 2 or replace LCM devices with
Automation Server I/O modules or MNL controllers● Global Control Satellite (GCS) bus will not be supported in either phase
●Replace GCS units with Automation Server I/O modules or MNL controllers
StruxureWare Building Operation v1.1 Scalability Guidelines:
Max # of ASD devices on the bus (per Automation Server) 128
Max # of Automation Servers(Sites using more than one Automation Server require an Enterprise Server) 10
Max # of Enterprise Servers 1
Max # of concurrent users(includes sum of WorkStation + WebStation users simultaneously) 2
Schneider Electric 8- Buildings – Roadmap– August 2011 COMPANY CONFIDENTIAL
System requirements
●NETWORK 8000 GCM controllers: Minimum v4.2
●StruxureWare Building Operation v1.1● Released: December 2011
●Microsoft OS & SQL versions:● Windows XP (32-bit)● Windows 7 (32-bit)● Windows Server 2008 (32-bit)● SQL Server 2008 - Express & Standard versions (32-bit)
●Required for Reports Server
9Schneider Electric - Buildings Business – Company Confidential
Engineering efficiencies●Introduction of Spreadsheet
● Spreadsheet enables creating and editing of multiple objects in a tabular format at once
● Supports copy/paste of cells to and from Microsoft Excel directly to the Spreadsheet view
●Rapidly create LonWorks Network Variables (NVs) ● Simplifies binding to external devices to the local node for value logging or
monitoring● No need to manually create the corresponding variable on the local node,
naming it, choosing the correct type, and then binding it
● v1.1 supports configuration of:
o Values
o Alarms
o Trends
o Automation Server’s I/O modules &
points
10Schneider Electric - Buildings Business – Company Confidential
StruxureWare Building Operation v1.2
G
Technology Highlights
• Scalable• Support for 32 Automation Servers
• Easy to Integrate• EcoStruxure using Ecostruxure Web Services
• Easy to Migrate• NETWORK 8000 – Phase 2 (of 2)
• Energy Efficient• Energy Report Pack
• IT Friendly• 64-bit Support• Encrypted communication by default
TARGET PRODUCT READINESS: Q2 2012
Schneider Electric 11- Buildings – Roadmap– August 2011 COMPANY CONFIDENTIAL
StruxureWare Building Operation v1.2Web Services – Two approaches supported
●Generic Consume● General web services implementation to “consume” data into StruxureWare● Ideal when integrating to third party systems● Two approaches:
●Binding tool, Script programming based
●Schneider Electric Corporate Web Services (CWS) - Serve & Consume● Support “serving” and/or “consuming” data from other Schneider Electric
products & systems● CWS offer web services functionality beyond what is capable via Generic
Consume approach● Functionality defined: Serve and Consume
●Browse●Data access read/write●Alarm access read and acknowledge●Trend access read only
Schneider Electric 12- Buildings – Roadmap– August 2011 COMPANY CONFIDENTIAL
Scalability guidelines in Version 1.2
StruxureWare Building Operation v1.1 components:
Recommended # of LCM devices on the bus (per Automation Server) 12
Max # of LCM devices on the bus (per Automation Server) 31
Max # of ASD devices on the bus (per Automation Server) 128
Max # of Automation Servers(Sites using more than one Automation Server require an Enterprise Server)
32
Max # of Enterprise Servers 1
Max # of concurrent users(includes sum of WorkStation + WebStation users simultaneously)
10
Company Confidential – Internal Use Only12
Schneider Electric 13- Buildings – Roadmap– August 2011 COMPANY CONFIDENTIAL
Phase 2: LCM support, SIGNAL conversion
●Phase 2: Available in StruxureWare Building Operation v1.2
● Adds support for LCM (Local Control Module) field bus directly under an Automation Server
● Similar procedures in Phase 2 (as Phase 1) for GCM database to Automation Server database conversion
● Use the same database conversion service
● Adds support for conversion of an LCM bus in the Automation Server
StruxureWare Building Operation
WorkStation
StruxureWare
Building Operation WebStation
Schneider Electric 14- Buildings – Roadmap– August 2011 COMPANY CONFIDENTIAL
G
Technology Highlights
• Easy to Migrate
• TAC I/NET (HVAC)
• Engineering Efficiency• Modbus multi-read• One Automation Server for LonWorks,
Modbus and BACnet combined
• Easy to Identify• StruxureWare Building Operation
TARGET PRODUCT READINESS: Q3 2012
StruxureWare Building Operation v1.3Previously designated as v1.2.1
Note: No change to deliverablesjust the version number to facilitatehaving more than one revision of thesoftware loaded on a machine.
Schneider Electric 15- Buildings – Roadmap– August 2011 COMPANY CONFIDENTIAL
●I/NET HVAC only
●Scalability guidelines
●I/NET sites using X527-NPRs and NPR 2000s● Includes X527 used only for NPR (routing Controller LAN to IP) and web access
Current TAC I/NET system:
Recommended max # of links per ES – e.g. X527-NPRs, NPR2000s 55
Recommended max # of I/NET points (internal/external) per ES 100,000
Recommended max # of I/NET LAN devices per link (X527-NPR or NPR2000)(Example: DCUs, PCUs, and MCIs)
32
Total Controller LAN I/NET devices per ES – e.g. DCUs, PCUs, MCIs 300
Add-on StruxureWare components (targeted for v1.2):
Max # of concurrent users(includes sum of WorkStation + WebStation users simultaneously)
10
Max # of Automation Servers added 32
StruxureWare Building Operation v1.3
Schneider Electric 16- Buildings – Roadmap– August 2011 COMPANY CONFIDENTIAL
StruxureWare Building Operation v1.3
Xenta
527-NPR
StruxureWare
WorkStation
StruxureWare Reports Server
StruxureWare
WebStation
StruxureWare Enterprise
Server
StruxureWare
WebReports
I/NET
database
Native Support:
BACnet IP Modbus TCP INET
BACnet MSTP Modbus RTU NW8k
LON IP Modbus ASCII