Area AnalysisSite AreaBuilding AreaPaving / Driveways
m2m2
PermeabilityTotal Site Coverage
m2
m249.03%
244.4
222.40479.50
22.00
Ground FloorStudio
m2
Total GroundPrivate Open Space
m2m2
Total Building Area
m2
m2
Unit
222.4
222.4
166.1056.30
1
132.7
Project:
Client:
Municipality:
Stage:
MITCHELL STREET156 MITCHELL STREET,
NORTHCOTE
STACEY & TONY
02.03.2018
156 MITCHELL STREET, NORTHCOTE
Project Status
DAREBIN
WORKING DRAWINGS-BUILDING PERMIT-WD03
Sheet List - ConstructionSheet
Number Sheet NameA00 COVER SHEETA01 GENERAL NOTESA02 EXISTING GROUND FLOOR PLANA03 EXISTING SITE PLANA04 EXISTING ROOF PLANA05 PROPOSED DEMOLITION PLANA06 PROPOSED GROUND FLOOR PLANA07 PROPOSED DIMENSIONED GROUND FLOOR PLANA08 PROPOSED SITE PLANA09 PROPOSED ROOF PLANA10 PROPOSED ELEVATIONSA11 PROPOSED ELEVATIONS 2A12 PROPOSED SECTIONA13 DETAIL SECTIONA14 PROPOSED ELECTRICAL PLANA15 PROPOSED WINDOW & DOOR SCHEDULEA16 3D VIEW- GLAZINGA17 3D VIEWS-1A18 3D VIEWS-2A19 3D VIEWS-3A20 Detail
GARDEN AREA 152 M2SITE AREA 479.50 M2
GARDEN AREA COVERAGE 31.7 %
-
NOTES (GENERAL):• DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS.• SITE DIMENSIONS ARE IN MILLIMETRES UNLESS OTHERWISE STATED.• ALL ARCHITECTURAL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH
ALL CONSULTANTS' DOCUMENTS: STRUCTURAL ENGINEERING, ENERGY RATINGS, SOIL TESTS, FIRE ENGINEERING AND MECHANICAL ENGINEERING.
• REFER TO STRUCTURAL ENGINEER'S DOCUMENTATION FOR FOOTING/FOUNDATION DETAILS AND FOR PREPARATION OF EXCAVATIONS.
• ALL WORKMANSHIP AND MATERIAL SHALL CONFORM TO ALL RELEVANT CODES AND VICTORIAN BUILDING REGULATIONS AND BUILDING CODE OF AUSTRALIA.
• BUILDER AND BUILDING CONTRACTORS SHALL VERIFY EXISTING SITE CONDITIONS PRIOR TO COMMENCEMENT OF ANY SITE WORKS.
• ALL ELECTRICAL WIRING TO BE PROVIDED BY A REGISTERED ELECTRICIAN.• IF IN DOUBT ASK, DO NOT GUESS.• CONTRACTORS MUST VERIFY ALL DIMENSIONS ON SITE BEFORE
COMMENCING ANY WORK OR PREPARING SHOP DRAWINGS.• ANY DISCREPANCIES MUST BE REPORTED TO THE ARCHITECT FOR
CLARIFICATION AND APPROVAL IN WRITING.• THE BUILDER SHALL TAKE ALL NECESSARY STEPS TO ENSURE THE
STABILITY OF NEW AND EXISTING STRUCTURES DURING ALL WORKS• THE BUILDER SHALL ENSURE FOR THE GENERAL WATER TIGHTNESS OF
ALL NEW AND EXISTING WORKS
SOIL CLASSIFICATION:• REFER TO SOIL REPORT.
GROUND WORKS:• EXCAVATE FOR FOOTINGS TO MINIMUM 100mm ONTO FIRM FOUNDATION
WITH MIN. 100kpA BEARING CAPACITY. REFER TO ENGINEER'S DETAILS.• FOOTINGS TO BE FOUNDED AT THE MINIMUM DEPTHS INDICATED IN THE
SOIL REPORT• FOOTINGS NOT TO ENCROACH ON BOUNDARIES AND EASEMENT LINES.• NEW STORMWATER PIPE TO BE CONNECTED INTO EXISTING
STORMWATER SYSTEM AND DISCHARGE TO PUBLIC STORM WATER DRAINAGE SYSTEM ACCORDING TO LOCAL AUTHORITIES REQUIREMENTS.
DRAINAGE:• ALL DRAINS SHALL COMPLY WITH ALL RELEVANT STANDARDS AND
APPROPRIATE REGULATORY BODIES AND DISCHARGE IN ACCORDANCE WITH THE RELEVANT CITY COUNCIL'S REQUIREMENTS.
• STORM WATER DRAINS GENERAL 90dia PVC• STORM WATER DRAINS EXCEEDING 6 INLETS OR UNDER
RESIDENCE/VEHICLE PAVING 100dia PVC• AGRICULTURAL DRAINS 90 PVC SLOTTED• SEWER DRAINS 100mm PVC• SILT PITS (AG TO SWD) 350mm SQUARE CONCRETE LID• JUNCTION PITS 450mm SQUARE BRICK OR CONCRETE• ALL DRAINAGE SHALL COMPLY WITH ENGINEERING DRAWINGS IF
SUPPLIED AND TAKE PRECEDENCE OVER THESE SPECIFICATIONS.
PLUMBING:• BUILDER SHALL ALLOW FOR THE FITTING OFF AND CONNECTION OF ALL
PLUMBING FIXTURES INDICATED ON PLANS. BUILDER SHALL ALSO ALLOW FOR THE SUPPLY AND INSTALLATION OF 2 EXTERNAL WATER TAPS TO LOCATIONS DIRECTED BY THE OWNER. DOWN PIPES, GUTTERS, SUMP & RAIN HEAD SIZES TO AS3500 - 2003
• PRESSURE EQUIPMENT TO COMPLY WITH AS1200 - 2000• TECHNICAL SPECIFICATIONS FOR PLUMBING AND DRAINAGE PRODUCTS
TO COMPLY WITH AS5200 - 2006• ALL PLUMBING WORK TO BE PROVIDED BY A REGISTERED PLUMBER.• WASTE FROM KITCHEN SINK AND OTHER SANITARY FITTINGS (SIZE TO BE
ESTABLISHED BY REGISTERED PLUMBER) TO BE DISCHARGED TO PUBLIC SEWERAGE SYSTEM
FOUNDATIONS:• ALL FOUNDATIONS TO COMPLY WITH AS2870 - 2011• REFER TO ENGINEER'S DRAWINGS FOR FULL DETAILS.• ALL FOUNDATIONS SHALL BE INSPECTED BY THE BUILDING INSPECTOR
PRIOR TO PLACING CONCRETE.• ANY VARIATION IN FOUNDATION MATERIAL FROM THAT SPECIFIED TO BE
NOTIFIED TO THE ENGINEER AND OWNER.• ALL REINFORCEMENT IN FOOTINGS AND PAD FOOTINGS SHALL BE
INSPECTED BY THE BUILDING INSPECTOR PRIOR TO POURING CONCRETE.• ALL CONCRETE SHALL BE 25MPa MIN. OR AS SPECIFIED IN STRUCTURAL
ENGINEER'S DETAIL. IT SHALL BE PROPERLY VIBRATED AND WORK TO BE DONE TO AS1480 - 1975
CONCRETE:• ALL CONCRETE SHALL COMPLY WITH ALL RELEVANT CODES AS3600 -
2009, AS2870 - 2011, AS1379 - 2007, AS3610 - 1995 AND IN ACCORD WITH ENGINEERS NOTES AND SPECIFICATION
• NOTE: REINFORCEMENT BARS SHALL BE SUPPORTED VIA CHAIRS AT A MAXIMUM OF 800mm CENTRES
TIMBER FRAMING:• ALL TIMBER SHALL COMPLY WITH AS1720.1 - 1997• TIMBER FLOORS TO COMPLY WITH AS1684.2 - 2010, AS1684.3 - 2012,
AS1684.4 - 2010• TIMBER STRUCTURES - DESIGN METHODS AS1720.1 - 2010• ALL FRAMING TO BE INSPECTED AND APPROVED BY THE BUILDING
INSPECTOR PRIOR TO COVERING UP ALL TIMBER FRAMING AND MATERIAL.
• ALL TIMBER TO BE PARTIALLY SEASONED UNLESS NOTED OTHERWISE.• ALL RAFTERS AND ROOF MEMBERS TO BE TIED DOWN TO SUPPORT
STRUCTURE USING STRAPS, PLATES, CLEATS, ETC BY "PRYDA" OR "TECO" COMPONENTS.
• BUILDER TO ENSURE THAT ALL WORK IS CARRIED OUT TO THESE SPECIFICATIONS AND NO SPANS OR SIZES TO VARY. NO SPLICES ARE PERMITTED WITHOUT ENGINEER'S WRITTEN CONSENT.
• ALL EXPOSED BOLTS, FIXINGS, ETC TO BE HOT DIP GALVANISED TO ACCORDANCE WITH AS1650 TO SUIT SITE EXPOSURE CONDITION.
• ALL TIMBER PRESERVATIVE TO ARCHITECT'S SPECIFICATION TO SUIT EXPOSURE CONDITIONS.
SUB-FLOOR VENTILATION:• PROVIDE MIN. 6000mm 2 SUB-FLOOR VENTILATION/m OF WALL, AS PER
PART 3.4.1 OF THE BCA. PROVIDE 'ALETA' OR EQUIVALENT, 230X160 BRASS WIRE VENT. (13,400mm^2 VENTILATION ACHIEVED PER VENT) 6000mm VENTILATION REQUIRED PER METRE OF WALL. VENTS TO BE CALCULATED AS FOLLOWS: (ie. WALL LENGTH 10m x 6000 = 60,000. 60,000 / 13,400 = 4.47 (5) VENTS REQUIRED. 10 / 6 = 1.6m MAX. SPACING) FOR ZONE 3.
• ALL INSULATION OF PARTICLEBOARD FLOORING TO COMPLY WITH AS1860 - 1998
WIND LOADS:• ALL STRUCTURES MUST BE TIED DOWN IN ACCORDANCE WITH AS4055 -
AMDT 1 - 2006 FOR CATEGORY N1 UNLESS OTHERWISE STATED.
STEEL:• ALL STEEL STRUCTURE TO COMPLY WITH AS4100 - 1998• COMPOSITE STRUCTURES TO COMPLY WITHAS2327 - 2003• COLD FORMED STEEL STRUCTURES TO COMPLY WITH AS4600 - 2005
INSULATION:• ALL INSULATION TO BE IN ACCORDANCE WITH AS4859.1 - 2009• REFER TO ENERGY RATINGS REPORT FOR FULL INSULATION
REQUIREMENTS.• WALL INSULATION TO BE ADOPTED IN FIRE RATED WALLS CONTAINING
TIMBER FRAMING TO BE NON-COMBUSTIBLE.• PROVIDE INSULATION BETWEEN FLOOR AND CEILING TO ACHIEVE A MIN,
Rw+Ctr RATING OF 50. PROVIDE 50 GLASSWOOL PARTITION BATTS -11kg/m^3
• RFL TO HAVE A FLAMMABILITY INDEX NOT EXCEEDING 5.
BRICKWORK:• ALL MASONRY SHALL COMPLY WITH AS3700 - 2001 OR AS4773.1 - 2010 AND
AS4773.2 - 2010• AS2699 AMDT 1 - 2000: ALL WALL TIES SHALL BE IN ACCORDANCE WITH
RELEVANT CODES AND SHALL BE GALVANISED. GENERALLY WALL TIES TO BE 600mm CENTERS IN EACH DIRECTION FOR CAVITY MASONRY, FOR MASONRY VENEER: 600x450 FOR 450 STUD WALLS AND 600x600 FOR 600 STUD WALLS AND WITHIN 300mm OF ARTICULATION JOINTS.
• PROVIDE WALL TIES TO BRICKWORK AT MAXIMUM 5000mm CENTERS IN EACH DIRECTION AND WITHIN 300mm OF ARTICULATION JOINTS 2200mm SQ. CLEAR VENTILATION PER 1000mm OF INTERNAL DWARF WALLS.
• SPACING OF WALL TIES TO TOP AND SIDES OF OPENINGS TO BE HALVED.• MASONRY IN SMALL BUILDINGS DESIGN - AS4773.1 - 2010,
CONSTRUCTION - AS4773.2 - 2010• BRICKWORK TO BE SELECTED BY CLIENT AND AGREED UPON BY BUILDER
TOILETS:• PROVIDE 1.2M MIN CLEAR FROM THE DOOR TO THE WC PAN, OR PROVIDE
LIFT OFF DOOR HINGES.
GLAZING:• ALL GLAZING SHALL COMPLY WITH AS1288 AMDT 1 - 2006 AND BE
CERTIFIED ON COMPLETION OF WORKS AS REQUIRED• ALL ROOMS WITHIN 500mm VERTICAL OF THE FLOOR• BATHROOMS WITHIN 1500mm VERTICAL FROM THE BATH BASE• LAUNDRY WITHIN 1200mm VERTICAL FROM THE FLOOR AND/OR WITHIN
300mm HORIZONTAL FROM ALL DOORS• DOORWAY WITHIN 300mm HORIZONTAL FROM ALL DOORS.• SHOWER SCREENS SHALL BE GRADE A SAFETY GLASS• ALL WINDOWS TO COMPLY WITH AS2047 - 1999TO DOORS AND SIDELIGHTS:• UP TO 0.5m2 - 6.38mm LAMINATED• GREATER THAN 5m2 - 6.38mm LAMINATEDTO WINDOWS:• UP TO 0.1m2 - 6.38mm LAMINATED• UP TO 0.3m2 - 6.38mm LAMINATED• UP TO 2.0m2 - 6.38mm LAMINATED• DOOR AND WINDOWS: UP TO 500mm FROM FLOOR - 6.38mm LAMINATED.• TO BATHROOMS AND ENSUITE WHERE WINDOWS ARE LOCATED OVER
BATHTUB OR WITHIN SHOWER • ENCLOSURE- SAFETY GLASS.
WET AREAS:• PROVIDE IMPERVIOUS WALLS, FLOOR AND FLASHINGS TO ALL WET AREAS
IN ACCORD WITH THE B.C.A. 2008 PART 3.8.1 AND AS3740 - 2010• WET AREA MEMBRANES TO COMPLY WITH AS4858 - 2004• INTERNAL- THE WALL AND FLOOR SURFACES OF A SHOWER ENCLOSURE,
ADJACENT OR BEHIND A BATH, BASIN TROUGH OR SINK SHALL BE IMPERVIOUS TO WATER IN ACCORDANCE WITH AS 3740 -2010
• THE WALL SURFACE OF A SHOWER ENCLOSURE SHALL BE IMPERVIOUS TO WATER TO A HEIGHT OF 1800mm
• THE FLOOR SURFACE TO ALL SANITARY COMPARTMENTS SHALL BE IMPERVIOUS TO WATER.
• THE WALL IMMEDIATELY ADJACENT OR BEHIND A BASIN, TROUGH OR SINK SHALL BE IMPERVIOUS TO WATER TO A HEIGHT NOT LESS THAN 150MM ABOVE THE FIXTURE.
• THE FLOOR SURFACE TO ALL SANITARY COMPARTMENTS SHALL BE IMPERVIOUS TO WATER.
• THE WALL IMMEDIATELY ADJACENT OR BEHIND A BASIN, TROUGH OR SINK SHALL BE IMPERVIOUS TO WATER TO A HEIGHT NOT LESS THAN 150MM ABOVE THE FIXTURE, IF IT IS WITHIN 75mm OF THE WALL.
• THE JUNCTIONS BETWEEN THE WALLS AND FIXTURES, THE WALLS WITHIN THE SHOWER COMPARTMENT AND THE WALLS AND THE FLOORS ARE REQUIRED TO BE IMPERVIOUS TO WATER.
• WHERE A SHOWER IS PROVIDED ABOVE THE BATH, FLOOR AND WALL SURFACES WITHIN A RADIUS OF 1500mm FROM THE SHOWERHEAD IS REQUIRED TO BE IMPERVIOUS TO WATER. WHERE NO SHOWER SCREEN IS PROVIDED, THE FLOOR IS REQUIRED TO BE PROVIDED WITH A FLOOR WASTE OUTLET.
• IF THE SHOWER IS UNENCLOSED, THE WALLS SHALL BE WATER RESISTANT TO A HEIGHT OF 1800MM FOR A LENGTH OF 1500mm FROM EITHER SIDE OF THE SHOWER HEAD.
• A WATER STOP MUST BE INSTALLED SO THAT ITS VERTICAL LEG WILL FINISH FLUSH WITH THE FLOOR LEVEL TO A 1500mm ARC FROM THE SHOWER HEAD. WHERE A WATER STOP INTERSECTS WITH A WALL OR IS JOINED, THE JUNCTION MUST BE WATERPROOF. FURTHERMORE THE AREA WITHIN THE 1500MM ARC SHALL BE GRADED BETWEEN 1:60 AND 1:80 TO THE SHOWER OUTLET.
• ALTERNATIVELY, THE WHOLE FLOOR MUST BE WATERPROOFED AND DRAINED TO A FLOOR WASTE AS FOR THE SHOWER AREA. THE FALL OF THE FLOOR OUTSIDE THE SHOWER AREA SHALL BE BETWEEN 1:80 AND 1:100 AND WITHIN THE SHOWER AREA SHALL BE 1:60 AND 1:80. A WATER STOP MUST BE PROVIDED AT THE DOORWAY TO THE BATHROOM.
VENTILATION:• WHERE APPLICABLE TO HAVE EFFECTIVE AIRWAY OF NOT LESS THAN
40,000mm^2 AND FIXED INLET VENTILATION OF NOT LESS THAN 8000mm^2 AT LOW LEVEL THROUGH THE EXTERNAL
• EXHAUST FANS TO ALL GROUND FLOOR APARTMENTS TO BE DUCTED TO OUTSIDE. EXHAUST FANS TO ALL LEVEL 1 APARTMENTS TO VENT INTO CEILING SPACE.
• PROVIDE CLEARANCE FROM UNDERSIDE OF BEARER TO FINISHED GROUND LEVEL OF 150mm FOR FLOOR WITH STRIP FLOORING OR 200mm FOR FLOORS WITH PARTICLEBOARD FLOORING OR 300mm WHERE IN TERMITE PRONE AREA.
ELECTRICAL:• PROVIDE NEW CIRCUIT BREAKER BOARDS, WIRING, POWER POINTS AND
LIGHT OUTLETS AS SCHEDULED TO COMPLY WITH RELEVANT VICTORIAN BUILDING CODES AND AUSTRALIAN STANDARDS. TO BE CARRIED OUT BY A QUALIFIED ELECTRICIAN.
STAIRS:• STAIRS SHALL COMPLY WITH 3.9.1 AND 3.9.2 OF NCC BCA 2013• RISERS MIN 115mm, MAX 190mm HIGH.• GOINGS MIN 240mm, MAX 355mm WIDE.• PRIVATE STAIRS (AND 250mm FOR PUBLIC STAIRS), RISERS AND TREADS
TO BE CONSTANT IN SIZE THROUGHOUT FLIGHT.• PROVIDE 865mm MIN HIGH HANDRAIL TO STAIRS FROM LINE OF NOSING.• PROVIDE CONTINUOUS HANDRAIL TO STAIRS IN ACCORDANCE WITH PART
3.9.2 OF NCC BCA 2014• PROVIDE 1000mm MIN HIGH HANDRAILS ABOVE FINISHED FLOOR LEVEL TO
LANDINGS AND BALCONIES.• PROVIDE 1000mm MIN HIGH HANDRAILS ABOVE FINISHED FLOOR LEVEL TO
CHANGE IN LEVELS EXCEEDING 900mm IN HEIGHT.• PROVIDE NON-SLIP FINISH OR SUITABLE NON-SKID STRIP NEAR EDGE OF
NOSING.• MAXIMUM OPENING BETWEEN BALUSTRADES NOT TO EXCEED 125mm.
ENSURE MAXIMUM GAP BETWEEN RISES NOT TO EXCEED 125mm OR USE CLOSED RISES.
• HANDRAILS TO COMPLY WITH 3.9.2.4 OF BCA 2013 AND AS 3700-2011.
GAS:• GAS INSTALLATIONS TO COMPLY WITH AS5601 - 2010
LIGHTING:• ARTIFICIAL LIGHTING TO COMPLY WITH AS/NZS1680.0 - 2009• ARTIFICIAL LIGHTING TO BE INSTALLED IN ACCORDANCE WITH PART
3.12.5.5 OF THE BCA 2012• INTERIOR AND WORKPLACE LIGHTING TO COMPLY WITH AS1680.1 - 2006
MECHANICAL VENTILATION:• MECHANICAL VENTILATION TO COMPLY WITH AS1668.2 2012
SMOKE DETECTORS:• LOCATION OF SMOKE ALARMS TO BE PROVIDED AND INSTALLED IN
ACCORDANCE WITH AS3786 - 1993 AMDT 1-4 - 2004 AND PART 3.7.2 OF THE BCA 2012 AND SHALL BE HARDWIRED WITH BATTERY BACKUP.
ACOUSTICS:• ACOUSTICS TO COMPLY WITH AS1276.1 - 1999
ROOFING:• SHEET ROOF AND WALL CLADDING - AS 1562.1 - 1992, AS1562.2 - 1992,
AS1562.3 - 1992• ROOF TILES - AS2049 AMDT 1 - 2002, AS2050 AMDT 1 - 2002• PLIABLE BUILDING MEMBRANES AND UNDERLAYS - AS4200 - 1994• DAMP-PROOF COURSES AND FLASHING - AS2904 - 1995• ROOFING TO BE SELECTED BY CLIENT AND AGREED UPON BY BUILDER
PLASTIC ROOFING AND WALL CLADDING:• ALL PLASTIC ROOFING AND WALL CLADDING MATERIALS TO COMPLY WITH
AS4256 - 1994/96
STORMWATER AND SERVICES:• STORMWATER SHALL COMPLY WITH AS/NZS3500.3 - 2003• STORMWATER SHALL BE TAKEN TO LEGAL POINT OF DISCHARGE TO THE
SATISFACTION OF THE RELEVANT AUTHORITY• SEWER OR SEPTIC SYSTEM SHALL BE IN ACCORDANCE WITH THE
RELEVANT AUTHORITIES REQUIREMENTS
CORROSION:• FOR BUILDINGS IN AREAS LESS THAN 1km FROM BREAKING SURF OR LESS
THAN 100m FROM SALTWATER NOT SUBJECT TO BREAKING SURF OR IN HEAVY INDUSTRIAL AREAS, WALL TIES SHALL BE EITHER GRADE 316 OR 316L STAINLESS STEEL, OR ENGINEERED POLYMER TIES.
THRESHOLDS:• IF A THRESHOLD SILL OF THE DOORWAY IS GREATER THAN 190mm ABOVE
THE FINISHED SURFACE OF THE GROUND TO WHICH THE DOORWAY OPENS, A LANDING SHALL BE PROVIDED NO LESS THAN THE WIDTH OF THE DOOR LEAF, OR 900mm WIDE x 900mm LONG, WHICHEVER IS GREATER.
ARCHITECTURAL DRAWINGS ARE TO BE READ IN CONJUNCTION WITH ALL CONSULTANTS AND ENGINEERING DRAWINGS AND DETAILS.DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONSIF IN DOUBT ASK, DO NOT GUESS.CONTRACTORS MUST VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK OR PREPARING SHOP DRAWINGS.ANY DISCREPANCIES MUST BE REPORTED TO THE ARCHITECT FOR CLARIFICATION AND APPROVAL IN WRITING.
PO BOX 271, Nortchote Plaza, Vic, 3070 | [email protected] | (03) 9484 8328
copyright of C. Kairouz Architects. prior written permission is necessary for reproduction.
C. KAIROUZ ARCHITECTSDATE:
SCALE:
JOB N :o
AMENDEMENT:PROJECT:
LOCATION:
CLIENT:
No in SET:
1 : 100
MITCHELL STREET
156 MITCHELL STREET, NORTHCOTE
STACEY & TONY
02.03.2018
CKA17-052A01
GENERAL NOTESNo. Description Date
-
RO
BE
ROBE
KITCHEN
LIN
EN
GAS
HEA
THER
SH
ENTRY
ROBE
LIVING
LIVINGCARPET
CARPET
BED1CARPETBED2
CARPET
BED3CARPET
TILETILE
BATHTILE
L'DRYTILE
WC
2600H
3400H
2600H 2600H
2600H2600H
3400H3400H
3400HPORCH
GARAGE
EX. SHED
CARPORT
CONCRETE
2400H
TILE
EXSITNG CONCRETE
EXISTING GRASS
EXSITNG BRICK TILE
EXSITNG BRICK TILE
SERVICE LANEWAY
EXISTING G
ATE
2638
1000
1500
Obscured Window
Obscured Window
ARCHITECTURAL DRAWINGS ARE TO BE READ IN CONJUNCTION WITH ALL CONSULTANTS AND ENGINEERING DRAWINGS AND DETAILS.DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONSIF IN DOUBT ASK, DO NOT GUESS.CONTRACTORS MUST VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK OR PREPARING SHOP DRAWINGS.ANY DISCREPANCIES MUST BE REPORTED TO THE ARCHITECT FOR CLARIFICATION AND APPROVAL IN WRITING.
PO BOX 271, Nortchote Plaza, Vic, 3070 | [email protected] | (03) 9484 8328
copyright of C. Kairouz Architects. prior written permission is necessary for reproduction.
C. KAIROUZ ARCHITECTSDATE:
SCALE:
JOB N :o
AMENDEMENT:PROJECT:
LOCATION:
CLIENT:
No in SET:
1 : 100
MITCHELL STREET
156 MITCHELL STREET, NORTHCOTE
STACEY & TONY
02.03.2018
CKA17-052A02
EXISTING GROUND FLOOR PLANNo. Description Date
-
RO
BE
ROBE
KITCHEN
LIN
EN
GAS
HEA
THER
SH
ENTRY
ROBE
LIVING
LIVINGCARPET
CARPET
BED1CARPETBED2
CARPET
BED3CARPET
TILETILE
BATHTILE
L'DRYTILE
WC
2600H
3400H
2600H 2600H
2600H2600H
3400H3400H
3400HPORCH
GARAGE
EX. SHED
CARPORT
CONCRETE
2400H
TILE
EXSITNG CONCRETE
EXISTING GRASS
EXSITNG BRICK TILE
EXSITNG BRICK TILE
MIT
CH
ELL
STR
EET
SERVICE LANEWAY
Obscured Window
Obscured Window
2638
1000
1500
ARCHITECTURAL DRAWINGS ARE TO BE READ IN CONJUNCTION WITH ALL CONSULTANTS AND ENGINEERING DRAWINGS AND DETAILS. DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS IF IN DOUBT ASK, DO NOT GUESS.CONTRACTORS MUST VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK OR PREPARING SHOP DRAWINGS. ANY DISCREPANCIES MUST BE REPORTED TO THE ARCHITECT FOR CLARIFICATION AND APPROVAL IN WRITING.
PO BOX 271, Nortchote Plaza, Vic, 3070 | [email protected] | (03) 9484 8328copyright of C. Kairouz Architects. prior written permission is necessary for reproduction.
C. KAIROUZ ARCHITECTSDATE:
SCALE:
JOB N :o
AMENDEMENT:PROJECT:
LOCATION:
CLIENT:
No in SET:
1 : 100
MITCHELL STREET
156 MITCHELL STREET, NORTHCOTE
STACEY & TONY
02.03.2018
CKA17-052 A03
EXISTING SITE PLANNo. Description Date
1 : 200 @ A3@A1
-
EX. SHED
EXISTING TILED ROOF STRUCTURESERVICE LANEWAYEXISTING METAL ROOF STRUCTURE
EXSITING DWELLINGEXISTING GARAGE
EXISTING METAL ROOF STRUCTURE TO BE REMOVED
EX. CARPORT
ARCHITECTURAL DRAWINGS ARE TO BE READ IN CONJUNCTION WITH ALL CONSULTANTS AND ENGINEERING DRAWINGS AND DETAILS.DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONSIF IN DOUBT ASK, DO NOT GUESS.CONTRACTORS MUST VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK OR PREPARING SHOP DRAWINGS.ANY DISCREPANCIES MUST BE REPORTED TO THE ARCHITECT FOR CLARIFICATION AND APPROVAL IN WRITING.
PO BOX 271, Nortchote Plaza, Vic, 3070 | [email protected] | (03) 9484 8328
copyright of C. Kairouz Architects. prior written permission is necessary for reproduction.
C. KAIROUZ ARCHITECTSDATE:
SCALE:
JOB N :o
AMENDEMENT:PROJECT:
LOCATION:
CLIENT:
No in SET:
1 : 100
MITCHELL STREET
156 MITCHELL STREET, NORTHCOTE
STACEY & TONY
02.03.2018
CKA17-052A04
EXISTING ROOF PLANNo. Description Date
-
KITCHEN
ENTRY
LIVING
LIVING
BED1BED2
BED3 BATHL'DRY
PORCH
GARAGE
SHED
CARPORT
PORCH
FRONT YARD LANDSCAPING & PAVING TO BE RETAINED
CONCRETE
2400H
CARPET
CARPET
CARPETCARPET
CARPET
TILETILE
TILETILE
2600H
3400H
2600H 2600H
2600H2600H
3400H3400H
3400H
CONCRETE
2400H
TILE
EXSITNG CONCRETE
EXSITNG BRICK TILE PAVING
EXSITNG BRICK TILE
GAS
HEA
THER
LIN
EN
WC
REMOVE EXSTING PAVING ANDPLANTER BOXES TO ACCOMODATE FOR PROPOSED WORKS
SIGNIFIES DEMOLITION
EXISTING GRASS
SERVICE LANEWAYREMOVE EXISTING CONCRETE TO MAKE WAY FOR NEW WORKS
ARCHITECTURAL DRAWINGS ARE TO BE READ IN CONJUNCTION WITH ALL CONSULTANTS AND ENGINEERING DRAWINGS AND DETAILS.DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONSIF IN DOUBT ASK, DO NOT GUESS.CONTRACTORS MUST VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK OR PREPARING SHOP DRAWINGS.ANY DISCREPANCIES MUST BE REPORTED TO THE ARCHITECT FOR CLARIFICATION AND APPROVAL IN WRITING.
PO BOX 271, Nortchote Plaza, Vic, 3070 | [email protected] | (03) 9484 8328
copyright of C. Kairouz Architects. prior written permission is necessary for reproduction.
C. KAIROUZ ARCHITECTSDATE:
SCALE:
JOB N :o
AMENDEMENT:PROJECT:
LOCATION:
CLIENT:
No in SET:
1 : 100
MITCHELL STREET
156 MITCHELL STREET, NORTHCOTE
STACEY & TONY
02.03.2018
CKA17-052A05
PROPOSED DEMOLITION PLANNo. Description Date
-
w.
DN
15 m²BED 2
13 m²BED 3
14 m²Living/Retreat
15 m²MASTER BED
7 m²BATH
5 m²ENS
ENTRY
PORCH
LIVING
DINING
3 m²WIP
TV U
NIT
/SH
ELVE
S
KITCHEN
DECKING
BBQ
PROPOSED WALL
EXISTING WALL
7 m²WIR
DES
K
DES
K
BEN
CH
6 m²L'DRY
RO
BE
FIREPLACE
F
window seat / storage below
Overhead cupboards
Stac
ker D
oor (
2600
h x
3770
w)
splashback window (700h x 3000w)
1300
h x
2100
w
(900h x 2200w)
(900h x 1900w)
(2300h x 1440w)
CU
PBO
ARD
WORK/STUDIO56.3 m2
8 m²STORAGE/SHED
OPEN PLAN LIVING 60.2 m2
SERVICE LANEWAY
CAR
SPAC
E
3.7m x 1.9m
3.1m x 1.7m
1.7m x 3.7m1.9m x 3.7m
3.6m x 4.1m
Double Sliding Door
(1300h x 2600w)
(170
0h x
270
0w)
(130
0h x
260
0w)
(1300h x 2020w)
RAISE CEILING HEIGHT TO 3.4M TO MATCH EXISTING FRONT OF DWELLING
3400H
3400H
3400H
3400H
3400H
3400H
3400H
3400H
Clothes Line
Infill wall to match existing wall
Infill wall to match existing wall
Tim
ber G
ate
(230
0h x
110
0w)
(900h x 1650w)
900h
x 2
200w
Stac
ker D
oor 2
200h
x 2
690w
15 m²BEDROOM 1
7 m²BATH
1
A12
W101
W402
W303
W404
W606
W505
FD 10
W909
W707
W1210
W1011
W1112
AD 01
BD 02
CD 03
CD 04
ND 05
DD 06
DD 07
GD 12
OD 13
PD 14
CD 08C
D 09
SHEL
VES
ED 15 12
00
1200
1000
2638
EXISTING G
ATE
DESK
CARSPACE
2
A12
6702
1202
2638
1
A20
1000
1500
Obscured Window
Obscured Window
1750
DN
1000
step
DN
150
mm
ARCHITECTURAL DRAWINGS ARE TO BE READ IN CONJUNCTION WITH ALL CONSULTANTS AND ENGINEERING DRAWINGS AND DETAILS.DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONSIF IN DOUBT ASK, DO NOT GUESS.CONTRACTORS MUST VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK OR PREPARING SHOP DRAWINGS.ANY DISCREPANCIES MUST BE REPORTED TO THE ARCHITECT FOR CLARIFICATION AND APPROVAL IN WRITING.
PO BOX 271, Nortchote Plaza, Vic, 3070 | [email protected] | (03) 9484 8328
copyright of C. Kairouz Architects. prior written permission is necessary for reproduction.
C. KAIROUZ ARCHITECTSDATE:
SCALE:
JOB N :o
AMENDEMENT:PROJECT:
LOCATION:
CLIENT:
No in SET:
1 : 100
MITCHELL STREET
156 MITCHELL STREET, NORTHCOTE
STACEY & TONY
02.03.2018
CKA17-052A06
PROPOSED GROUND FLOOR PLANNo. Description Date
NOTES:
- Ceiling insulation plus foil R6.0.- Wall insulation R2.5 plus foil to all existing walls.- Seal gaps, cracks and exhaust fans. - Weather-strip windows and entry doors. - New window frames to double glazed type U-4.5 & SHGC-0.61 or approved equivalent.
-
w.
15 m²BED 2
13 m²BED 3
14 m²Living/Retreat
15 m²MASTER BED
7 m²BATH
5 m²ENS
1200 ENTRY
PORCH
LIVING
DINING
3 m²WIP
TV U
NIT
/SH
ELVE
S
KITCHEN
PROPOSED WALL
EXISTING WALL
7 m²WIR
DES
K
DES
K
BEN
CH
6 m²L'DRY
RO
BE
FIREPLACE
F
window seat
Overhead cupboards
Stac
ker D
oor (
2300
h x
3770
w)
splashback window (700h x 3000w)
1300
h x
2100
w
(900h x 2200w)
(900h x 1900w)
(2300h x 1440w)
8 m²STORAGE/SHED
OPEN PLAN LIVING 60.2 m2
3.7m x 1.9m
3.1m x 1.7m1.7m x 1.3m
1.7m x 3.7m1.9m x 3.7m
3.6m x 4.1m
Double Sliding Door
(1300h x 2600w)
(170
0h x
270
0w)
(130
0h x
254
0w)
(1300h x 2020w)
3400H
3400H
3400H
3400H
3400H3400H
3400H
3400H
Tim
ber G
ate
(230
0h x
110
0w)
(900h x 1650w)
900h
x 2
200w
Stac
ker D
oor 2
100h
x 2
690w
15 m²BEDROOM 1
7 m²BATH
WORK STUDIO7080 960
1502870
240
Living5670
90
L'dry1700
90
Bath1900
1703620 170 4210 240
240 17620 240
OVERALL
OPENINGS
WALLS
WALLS
STU
DIO
9480
240
BAT H
3300
9056
1024
0STUDIO
7080
490 1650 4940
240 2000 90 4510 240
OVE
RAL
L
WAL
LSOVERALL
OPENINGS
WALLS
790
2200
3060
2690
740
OPE
NIN
GS
3000 2656 2200 1565EXISTING
18100
2600 4940
2020 5420
OVERALL
OPENINGS
240
KITCHEN4880 90
WIP1290
90
ENS3110 160
MASTER BED4110 90
RETREAT3800 240 WALLS
240DINING
5670 90
WIR3700 160 4110 90 3800 240 WALLS
EXIS
TIN
G
9260
5250
3770
Stac
ker D
oor 2
100h
x 3
770w
900h
x 2
200w
240
240
2330
9025
9090
OVE
RAL
L
OPE
NIN
GS
WAL
LS
WAL
LS
240
ENS
1700
90
WIR
1930
90
CO
RR
IDO
R
1200
90
BAT H
3680
240
OVE
RAL
L
WAL
LS
150
1050
8
1728
150
5408
150
2030 2000 1925 725
18100
1139
9260
710
2700
690
1100
720
2600
740
OPE
NIN
GS
CU
PBO
ARD
DESK
WORK/STUDIO56.3 m2
EXISTING G
ATE
Prop
osed
1638
ARCHITECTURAL DRAWINGS ARE TO BE READ IN CONJUNCTION WITH ALL CONSULTANTS AND ENGINEERING DRAWINGS AND DETAILS.DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONSIF IN DOUBT ASK, DO NOT GUESS.CONTRACTORS MUST VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK OR PREPARING SHOP DRAWINGS.ANY DISCREPANCIES MUST BE REPORTED TO THE ARCHITECT FOR CLARIFICATION AND APPROVAL IN WRITING.
PO BOX 271, Nortchote Plaza, Vic, 3070 | [email protected] | (03) 9484 8328
copyright of C. Kairouz Architects. prior written permission is necessary for reproduction.
C. KAIROUZ ARCHITECTSDATE:
SCALE:
JOB N :o
AMENDEMENT:PROJECT:
LOCATION:
CLIENT:
No in SET:
1 : 100
MITCHELL STREET
156 MITCHELL STREET, NORTHCOTE
STACEY & TONY
02.03.2018
CKA17-052A07
PROPOSED DIMENSIONEDGROUND FLOOR PLAN No. Description Date
-
w.
DN
15 m²BED 2
13 m²BED 3
14 m²Living/Retreat
15 m²MASTER BED
7 m²BATH
5 m²ENS
1200 ENTRY
PORCH
LIVING
DINING
3 m²WIP
TV U
NIT
/SH
ELVE
S
KITCHEN
DECKING 29.7 m2
7 m²WIR
DES
K
DES
K
BEN
CH
6 m²L'DRY
RO
BE
BEDROOM1
FIREPLACE
F
window seat
BATH
Overhead cupboards
Stac
ker W
indo
w (2
300h
x 3
770w
)
splashback window (700h x 3000w)
1300
h x
2100
w
(900h x 2200w)
(900h x 1650w)
(2300h x 1440w)
8 m²STORAGE/SHED
OPEN PLAN LIVING 60.2 m2
MIT
CH
ELL
STR
EET
SERVICE LANEWAY
Clothes Line
Tim
ber G
ate
(900h x 1650w)
900h
x 2
200w
Stac
ker D
oor 2
100h
x 2
690w
CAR
SPAC
E
1
A12
EXISTING G
ATE
CU
PBO
ARD
WORK/STUDIO56.3 m2
DESK
BBQ
2
A12
1
A20
1000
1000
1500
Obscured Window
Obscured Window
CARSPACE
PROPOSED WALL
EXISTING WALL
ARCHITECTURAL DRAWINGS ARE TO BE READ IN CONJUNCTION WITH ALL CONSULTANTS AND ENGINEERING DRAWINGS AND DETAILS. DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS IF IN DOUBT ASK, DO NOT GUESS.CONTRACTORS MUST VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK OR PREPARING SHOP DRAWINGS. ANY DISCREPANCIES MUST BE REPORTED TO THE ARCHITECT FOR CLARIFICATION AND APPROVAL IN WRITING.
PO BOX 271, Nortchote Plaza, Vic, 3070 | [email protected] | (03) 9484 8328copyright of C. Kairouz Architects. prior written permission is necessary for reproduction.
C. KAIROUZ ARCHITECTSDATE:
SCALE:
JOB N :o
AMENDEMENT:PROJECT:
LOCATION:
CLIENT:
No in SET:
1 : 100
MITCHELL STREET
156 MITCHELL STREET, NORTHCOTE
STACEY & TONY
02.03.2018
CKA17-052 A08
PROPOSED SITE PLANNo. Description Date
1 : 200 @ A3@A1
NOTES:
- Ceiling insulation plus foil R6.0.- Wall insulation R2.5 plus foil to all existing walls.- Seal gaps, cracks and exhaust fans. - Weather-strip windows and entry doors. - New window frames to double glazed type U-4.5 and SHGC-0.61 or approved equivalent.
-
SERVICE LANEWAY1.
00°
PROPOSED GLAZING ROOF STRUCTURE
EXISTING DWELLING
PROPOSED TIN SHED
proposed dp
proposed dp
existing dp
existing dp
existing dp
ARCHITECTURAL DRAWINGS ARE TO BE READ IN CONJUNCTION WITH ALL CONSULTANTS AND ENGINEERING DRAWINGS AND DETAILS.DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONSIF IN DOUBT ASK, DO NOT GUESS.CONTRACTORS MUST VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK OR PREPARING SHOP DRAWINGS.ANY DISCREPANCIES MUST BE REPORTED TO THE ARCHITECT FOR CLARIFICATION AND APPROVAL IN WRITING.
PO BOX 271, Nortchote Plaza, Vic, 3070 | [email protected] | (03) 9484 8328
copyright of C. Kairouz Architects. prior written permission is necessary for reproduction.
C. KAIROUZ ARCHITECTSDATE:
SCALE:
JOB N :o
AMENDEMENT:PROJECT:
LOCATION:
CLIENT:
No in SET:
1 : 100
MITCHELL STREET
156 MITCHELL STREET, NORTHCOTE
STACEY & TONY
02.03.2018
CKA17-052A09
PROPOSED ROOF PLANNo. Description Date
-
BOU
ND
ARY
BOU
ND
ARY
3400
C.L
F.L
WORK STUDIO EXISTING DWELLINGPROPOSED EXTENSIONPROPOSED DECKING
PROPOSED RENDER FINISH TO EXTERIOR AS PER CLIENTS SELECTION
FD 10
W505 W3
03
3115
G.C.L
G.F.L
N.G.L
2907 3
763
150 DECKING
BOU
ND
ARY
BOU
ND
ARY
C.L
F.L
3400
EXISTING DWELLING
PROPOSED RENDER FINISH TO EXTERIOR AS PER CLIENTS SELECTION
DECKING
PROPOSED WORK STUDIO
W606 W7
07
W1112
G.C.L
G.F.L150
3205
STEPS
ARCHITECTURAL DRAWINGS ARE TO BE READ IN CONJUNCTION WITH ALL CONSULTANTS AND ENGINEERING DRAWINGS AND DETAILS.DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONSIF IN DOUBT ASK, DO NOT GUESS.CONTRACTORS MUST VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK OR PREPARING SHOP DRAWINGS.ANY DISCREPANCIES MUST BE REPORTED TO THE ARCHITECT FOR CLARIFICATION AND APPROVAL IN WRITING.
PO BOX 271, Nortchote Plaza, Vic, 3070 | [email protected] | (03) 9484 8328
copyright of C. Kairouz Architects. prior written permission is necessary for reproduction.
C. KAIROUZ ARCHITECTSDATE:
SCALE:
JOB N :o
AMENDEMENT:PROJECT:
LOCATION:
CLIENT:
No in SET:
1 : 100
MITCHELL STREET
156 MITCHELL STREET, NORTHCOTE
STACEY & TONY
02.03.2018
CKA17-052A10
PROPOSED ELEVATIONSNo. Description Date
1 Revision 1 Date 1
EAST ELEVATION
WEST ELEVATION NOTES:- Ceiling insulation plus foil R6.0.- Wall insulation R2.5 plus foil to all existing walls.- Seal gaps, cracks and exhaust fans. - Weather-strip windows and entry doors. - New window frames to double glazed type U-4.5 and SHGC-0.61 or approved equivalent.
-
BOU
ND
ARY
BOU
ND
ARY
C.L
F.L
3400
EXISTING DWELLING
PROPOSED EXTENSION
PROPOSED DOOR AS PER CLIENTS SELECTION
PROPOSED RENDER FINISH TO EXTERIOR AS PER CLIENTS SELECTION
AD 01 W1
01
W402
BOU
ND
ARY
BOU
ND
ARY
C.L
F.L
3400
SERVING BENCH
EXISTING DWELLING
PROPOSED EXTENSION
PROPOSED RENDER FINISH TO EXTERIOR AS PER CLIENTS SELECTION
DECKING
W909
W1519
2907
PROPOSED DECKING
3
76
3
STEPS
150
ARCHITECTURAL DRAWINGS ARE TO BE READ IN CONJUNCTION WITH ALL CONSULTANTS AND ENGINEERING DRAWINGS AND DETAILS.DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONSIF IN DOUBT ASK, DO NOT GUESS.CONTRACTORS MUST VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK OR PREPARING SHOP DRAWINGS.ANY DISCREPANCIES MUST BE REPORTED TO THE ARCHITECT FOR CLARIFICATION AND APPROVAL IN WRITING.
PO BOX 271, Nortchote Plaza, Vic, 3070 | [email protected] | (03) 9484 8328
copyright of C. Kairouz Architects. prior written permission is necessary for reproduction.
C. KAIROUZ ARCHITECTSDATE:
SCALE:
JOB N :o
AMENDEMENT:PROJECT:
LOCATION:
CLIENT:
No in SET:
1 : 100
MITCHELL STREET
156 MITCHELL STREET, NORTHCOTE
STACEY & TONY
02.03.2018
CKA17-052A11
PROPOSED ELEVATIONS 2No. Description Date
1 Revision 1 Date 1
NORTH ELEVATION
SOUTH ELEVATIONNOTES:
- Ceiling insulation plus foil R6.0.- Wall insulation R2.5 plus foil to all existing walls.- Seal gaps, cracks and exhaust fans. - Weather-strip windows and entry doors. - New window frames to double glazed type U-4.5 and SHGC-0.61 or approved equivalent.
-
3400
BOU
ND
ARY
BOU
ND
ARY
C.L
EX. F.L
EXISTING DWELLING
PROPOSED EXTENSION
2733
EXISTING FLOOR
PROPOSED 100 mm CONCRETE SLAB ON GROUND REFER TO ENGINEERING DETAILS FOR FURTHER DETAILS
EXISTING
EXISTING ROOF TO BE TRIMMED
PROPOSED GLAZED ROOF SYSTEM, REFER TO ENGINEERING FOR FURTHER DETAILS
PROPOSED FACIA & GUTTER TO MATCH EXISTING
N.G.L.PROPOSED 600mm DEEP x 350mm WIDE EDGE BEAM, REFER TO ENGINEERING FOR FURTHER DETAILS
EXISTING FOOTING TO BE CONFIRMED ON SITE, REFER TO ENGINEERING DRAWINGS FOR FURTHER DETAILS
REFER TO ENGINEERING DRAWINGS FOR BEAM SIZES AND DETAILS
EXISTING CEILING TO BE RAISED TO MATCH FRONT OF DWELLING
rais
ed c
eilin
g he
ight
3400
1A13
2911
MIN
.CEI
LIN
G H
EIG
HT
2
40
0
Boun
dary
Boun
daryPROPOSED WORK STUDIO
Garage F.F.LN.G.L N.G.L
ARCHITECTURAL DRAWINGS ARE TO BE READ IN CONJUNCTION WITH ALL CONSULTANTS AND ENGINEERING DRAWINGS AND DETAILS.DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONSIF IN DOUBT ASK, DO NOT GUESS.CONTRACTORS MUST VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK OR PREPARING SHOP DRAWINGS.ANY DISCREPANCIES MUST BE REPORTED TO THE ARCHITECT FOR CLARIFICATION AND APPROVAL IN WRITING.
PO BOX 271, Nortchote Plaza, Vic, 3070 | [email protected] | (03) 9484 8328
copyright of C. Kairouz Architects. prior written permission is necessary for reproduction.
C. KAIROUZ ARCHITECTSDATE:
SCALE:
JOB N :o
AMENDEMENT:PROJECT:
LOCATION:
CLIENT:
No in SET:
1 : 50
MITCHELL STREET
156 MITCHELL STREET, NORTHCOTE
STACEY & TONY
02.03.2018
CKA17-052A12
PROPOSED SECTIONNo. Description Date
1 : 501 Section AA
1 : 50A062 Section BB
-
2733
EXISTING CONDITIONS TO BE VERIFIED BY BUILDER ON SITE
EXISTING DWELLING
RAISE EXISTING CEILING HEIGHT TO MATCH FRONT OF DWELLING
EXISTING ROOF
N.G.L
PROPOSED 100 mm CONCRETE SLAB ON GROUND REFER TO ENGINEERING DETAILS FOR FURTHER DETAILS
EXISTING ROOF TO BE TRIMMED
PROPOSED GLAZED ROOF SYSTEM, REFER TO ENGINEERING FOR FURTHER DETAILS
PROPOSED FACIA & GUTTER TO MATCH EXISTING
PROPOSED 600mm DEEP x 350mm WIDE EDGE BEAM, REFER TO ENGINEERING FOR FURTHER DETAILS
PROPOSED BEAM TO CONNECT WITH EXISTING; REFER TO ENGINEERING DRAWINGS FOR BEAM SIZES AND DETAILS B
OU
ND
ARY
EXISTING SLAB
3400
C.L
F.L
ARCHITECTURAL DRAWINGS ARE TO BE READ IN CONJUNCTION WITH ALL CONSULTANTS AND ENGINEERING DRAWINGS AND DETAILS.DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONSIF IN DOUBT ASK, DO NOT GUESS.CONTRACTORS MUST VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK OR PREPARING SHOP DRAWINGS.ANY DISCREPANCIES MUST BE REPORTED TO THE ARCHITECT FOR CLARIFICATION AND APPROVAL IN WRITING.
PO BOX 271, Nortchote Plaza, Vic, 3070 | [email protected] | (03) 9484 8328
copyright of C. Kairouz Architects. prior written permission is necessary for reproduction.
C. KAIROUZ ARCHITECTSDATE:
SCALE:
JOB N :o
AMENDEMENT:PROJECT:
LOCATION:
CLIENT:
No in SET:
1 : 20
MITCHELL STREET
156 MITCHELL STREET, NORTHCOTE
STACEY & TONY
02.03.2018
CKA17-052A13
DETAIL SECTIONNo. Description Date
-
w.
DN
15 m²BED 2
13 m²BED 3
14 m²Living/Retreat
15 m²MASTER BED
7 m²BATH
5 m²ENS
ENTRY
PORCH
LIVING
DINING
3 m²WIP
TV U
NIT
/SH
ELVE
S
KITCHEN
PROPOSED WALL
EXISTING WALL
7 m²WIR
DES
K
DES
K
BEN
CH
6 m²L'DRY
RO
BE
FIREPLACE
F
window seat
Overhead cupboards
8 m²STORAGE/SHED
OPEN PLAN LIVING 60.2 m2
3400H
Tim
ber G
ate
15 m²BEDROOM 1
7 m²BATH
wind
ow
seat
SDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSD
TELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTEL
TVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTV
TELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTEL
TVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTV
UPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUP
RHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRH
SDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSD
Heating wall panelHeating wall panel
Heating wall panel
Heating wall panel
Heating wall panel
Heating wall panel
Heating wall panel
Heat
ing
wal
l pan
el
Heat
ing
wal
l pan
el
Heat
ing
wal
l pan
el
3in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in1
USBUSB
3in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in1
USB
USB
3in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in1
CU
PBO
ARD
WORK/STUDIO56.3 m2
DESK
ELECTRICAL KEY:
LOW VOLTAGE DOWNLIGHTS
FEATURE PENDANT
UP LIGHT IN FLOOR OR GARDEN BED
EXHAUST FAN
LIGHT SWITCH
CEILING GPO
SINGLE GPO
DOUBLE GPO
GPO WITHIN O/HEAD CUPBOARDS FOR RANGEHOOD
LED STRIP
RECESSED WALL LIGHTS - 50mm AFFL
ADJUSTABLE DOWNLIGHT
FLUORESCENT LIGHT
RECESSED FLUORESCENT FIFFUSER
CARRIAGE LIGHTS
3 WAY IXL - LIGHT, FAN AND EXHAUST
SMOKE DETECTOR (HARD WIRED)
DATA POINT
TELEPHONE POINT
TELEVISION ANTENNA POINT
ALARM PAD
ELECTRICAL FLOOR BOX
CEILING FAN (L) LIGHT COMBINATION
CHANDALIER - PROVIDE ADDITIONALCEILING SUPPORT
EXTERNAL WALL MOUNTED LIGHT
EXTERNAL FLOOD LIGHT NON GLARE
EXTERNAL FLOOD LIGHT NON GLARE WITH SENSOR
RECESSED WALL WATER PROOF LIGHT
GARDEN LIGHT
BOLLARD LIGHT
EXHAUST FAN SQUARE
NOTE:POWERPOINTS WITHIN WET AREAS TO BE INSTALLED TO MINIMUM HEIGHT ABOVE BENCH TO CODE
PROVIDE NEW CIRCUIT BREAKER BOARDS, WIRING, POWERPOINTS AND LIGHT OUTLETS AS SCHEDULED TO COMPLY WITH RELEVANT AUSTRALIAN STANDARDS. TO BE CARRIED OUT BY A QUALIFIED ELECTRICAIN
3in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in1
UPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUP
RHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRH
SDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSD
TELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTEL
TVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTV
UPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUP
SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
exexexexexexexexexexexexexexexexexexexexexexexexexexexexexexexexex
FBFBFBFBFBFBFBFBFBFBFBFBFBFBFBFBFBFBFBFBFBFBFBFBFBFBFBFBFBFBFBFBFB
LLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLL
ARCHITECTURAL DRAWINGS ARE TO BE READ IN CONJUNCTION WITH ALL CONSULTANTS AND ENGINEERING DRAWINGS AND DETAILS.DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONSIF IN DOUBT ASK, DO NOT GUESS.CONTRACTORS MUST VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK OR PREPARING SHOP DRAWINGS.ANY DISCREPANCIES MUST BE REPORTED TO THE ARCHITECT FOR CLARIFICATION AND APPROVAL IN WRITING.
PO BOX 271, Nortchote Plaza, Vic, 3070 | [email protected] | (03) 9484 8328
copyright of C. Kairouz Architects. prior written permission is necessary for reproduction.
C. KAIROUZ ARCHITECTSDATE:
SCALE:
JOB N :o
AMENDEMENT:PROJECT:
LOCATION:
CLIENT:
No in SET:
1 : 100
MITCHELL STREET
156 MITCHELL STREET, NORTHCOTE
STACEY & TONY
02.03.2018
CKA17-052A14
PROPOSED ELECTRICAL PLANNo. Description Date
-
W1 / 01 Aluminium Frame - Living / Retreat
Existing window to be replaced with double glazing window
W3 / 03 Aluminium Frame - Bedroom 3
Existing window to be replaced with double glazing window
W4 / 04 (Master Bed) 02 (Bedroom 2) Aluminium Frame
Existing window to be replaced with double glazing window
W5 / 05Aluminium Frame -Bathroom
W6 / 06Aluminium Frame -Ens
W8 / 08Aluminium Frame - KitchenOPEN UP WINDOW - As per clients selection
W9 / 09Aluminium Frame -Living & Dining
W10 / 11Aluminium Frame -Work Studio
W11 / 12Aluminium Frame -Work Studio / Bathroom
W7 / 07Aluminium Frame -Kitchen
A / D01Feature Entry DoorEntry
B / D02Solid Double Sliding DoorLiving / Retreat
C Solid Core Interior DoorHinged D03 - Bedroom 2D04 - Bedroom 3 D05 - Master BedroomD08 - Bath D09 - L'dryD13 - Studio / Bedroom 1 D14 - Studio / Bath
GSolid Core Interior Door- Sliding D12 - WIP
E / D15Solid Single Sliding DoorCorridor- Dining & LivingFrosted Glass
F / D10Glazed Core Interior DoorHingedL'dry
400
2100 17
00
2700
800
1300
2100
2020
800
1300
2100
2600
1200
900
2100
1900
1200
900
2200
2100
875
700
1575
3000
1300
900
2200
1650
875
1725
2600
2100 3770
2600
2340
2
34
0
1440 820
2
34
0
1100 720
2
34
0
1000
2
34
0
820
W12 / 10Aluminium Frame -Work Studio / Bedroom
900
1300
2200
2200
820
2
34
0
DSolid Core Interior DoorSliding D07 - ENSD06 - WIR
Frosted Glass
2
34
0
2690
2200
ARCHITECTURAL DRAWINGS ARE TO BE READ IN CONJUNCTION WITH ALL CONSULTANTS AND ENGINEERING DRAWINGS AND DETAILS.DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONSIF IN DOUBT ASK, DO NOT GUESS.CONTRACTORS MUST VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK OR PREPARING SHOP DRAWINGS.ANY DISCREPANCIES MUST BE REPORTED TO THE ARCHITECT FOR CLARIFICATION AND APPROVAL IN WRITING.
PO BOX 271, Nortchote Plaza, Vic, 3070 | [email protected] | (03) 9484 8328
copyright of C. Kairouz Architects. prior written permission is necessary for reproduction.
C. KAIROUZ ARCHITECTSDATE:
SCALE:
JOB N :o
AMENDEMENT:PROJECT:
LOCATION:
CLIENT:
No in SET:
1 : 50
MITCHELL STREET
156 MITCHELL STREET, NORTHCOTE
STACEY & TONY
02.03.2018
CKA17-052A15
PROPOSED WINDOW & DOORSCHEDULE No. Description Date
1 Revision 1 Date 1
NOTES:- Ceiling insulation plus foil R6.0.- Wall insulation R2.5 plus foil to all existing walls.- Seal gaps, cracks and exhaust fans. - Weather-strip windows and entry doors. - New window frames to double glazed type U-4.5 & SHGC-0.61 or approved equivalent.
-
PROPOSED GLAZING ROOF STRUCTURE
6060
3603
550
950
3053
W15 / 19Aluminum Frame - Proposed Extension areaRefer to manufacturers manual or further details
W151936
53
2828
1520
ARCHITECTURAL DRAWINGS ARE TO BE READ IN CONJUNCTION WITH ALL CONSULTANTS AND ENGINEERING DRAWINGS AND DETAILS.DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONSIF IN DOUBT ASK, DO NOT GUESS.CONTRACTORS MUST VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK OR PREPARING SHOP DRAWINGS.ANY DISCREPANCIES MUST BE REPORTED TO THE ARCHITECT FOR CLARIFICATION AND APPROVAL IN WRITING.
PO BOX 271, Nortchote Plaza, Vic, 3070 | [email protected] | (03) 9484 8328
copyright of C. Kairouz Architects. prior written permission is necessary for reproduction.
C. KAIROUZ ARCHITECTSDATE:
SCALE:
JOB N :o
AMENDEMENT:PROJECT:
LOCATION:
CLIENT:
No in SET:
Asindicated
MITCHELL STREET
156 MITCHELL STREET, NORTHCOTE
STACEY & TONY
02.03.2018
CKA17-052A16
3D VIEW- GLAZINGNo. Description Date
3D View - GLAZING
Scale 1:50 - FRONT VIEW Scale 1:50 - SIDE VIEW
Scale 1:100 - ROOF PLAN
FOR GLAZING STRUCTURE DESIGN & INSTALLATION; REFER TO MANUFACTURERS MANUAL FOR FURTHER DETAILS
-
ARCHITECTURAL DRAWINGS ARE TO BE READ IN CONJUNCTION WITH ALL CONSULTANTS AND ENGINEERING DRAWINGS AND DETAILS.DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONSIF IN DOUBT ASK, DO NOT GUESS.CONTRACTORS MUST VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK OR PREPARING SHOP DRAWINGS.ANY DISCREPANCIES MUST BE REPORTED TO THE ARCHITECT FOR CLARIFICATION AND APPROVAL IN WRITING.
PO BOX 271, Nortchote Plaza, Vic, 3070 | [email protected] | (03) 9484 8328
copyright of C. Kairouz Architects. prior written permission is necessary for reproduction.
C. KAIROUZ ARCHITECTSDATE:
SCALE:
JOB N :o
AMENDEMENT:PROJECT:
LOCATION:
CLIENT:
No in SET:MITCHELL STREET
156 MITCHELL STREET, NORTHCOTE
STACEY & TONY
02.03.2018
CKA17-052A17
3D VIEWS-1No. Description Date
KITCHEN AREA
-
ARCHITECTURAL DRAWINGS ARE TO BE READ IN CONJUNCTION WITH ALL CONSULTANTS AND ENGINEERING DRAWINGS AND DETAILS.DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONSIF IN DOUBT ASK, DO NOT GUESS.CONTRACTORS MUST VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK OR PREPARING SHOP DRAWINGS.ANY DISCREPANCIES MUST BE REPORTED TO THE ARCHITECT FOR CLARIFICATION AND APPROVAL IN WRITING.
PO BOX 271, Nortchote Plaza, Vic, 3070 | [email protected] | (03) 9484 8328
copyright of C. Kairouz Architects. prior written permission is necessary for reproduction.
C. KAIROUZ ARCHITECTSDATE:
SCALE:
JOB N :o
AMENDEMENT:PROJECT:
LOCATION:
CLIENT:
No in SET:MITCHELL STREET
156 MITCHELL STREET, NORTHCOTE
STACEY & TONY
02.03.2018
CKA17-052A18
3D VIEWS-2No. Description Date
DECKING AREA
-
ARCHITECTURAL DRAWINGS ARE TO BE READ IN CONJUNCTION WITH ALL CONSULTANTS AND ENGINEERING DRAWINGS AND DETAILS.DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONSIF IN DOUBT ASK, DO NOT GUESS.CONTRACTORS MUST VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK OR PREPARING SHOP DRAWINGS.ANY DISCREPANCIES MUST BE REPORTED TO THE ARCHITECT FOR CLARIFICATION AND APPROVAL IN WRITING.
PO BOX 271, Nortchote Plaza, Vic, 3070 | [email protected] | (03) 9484 8328
copyright of C. Kairouz Architects. prior written permission is necessary for reproduction.
C. KAIROUZ ARCHITECTSDATE:
SCALE:
JOB N :o
AMENDEMENT:PROJECT:
LOCATION:
CLIENT:
No in SET:MITCHELL STREET
156 MITCHELL STREET, NORTHCOTE
STACEY & TONY
02.03.2018
CKA17-052A19
3D VIEWS-3No. Description Date
LIVING AREA
TV & SHELVES
SHELVES & FEATURE SLIDING DOOR
FIREPLACE
-
N.G.LN.G.L
N.G.L
Min
.Hei
ght c
lear
ance
2400
External Deck F.F.L
Internal Garage F.F.L
Natural Ground levelNatural Ground level
Proposed Work Studio
Existing Dwelling
Proposed Outdoor Decking
Internal Dwelling F.F.L
G.C.L
G.F.L
C.L
F.F.L
3400
150
ARCHITECTURAL DRAWINGS ARE TO BE READ IN CONJUNCTION WITH ALL CONSULTANTS AND ENGINEERING DRAWINGS AND DETAILS.DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONSIF IN DOUBT ASK, DO NOT GUESS.CONTRACTORS MUST VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK OR PREPARING SHOP DRAWINGS.ANY DISCREPANCIES MUST BE REPORTED TO THE ARCHITECT FOR CLARIFICATION AND APPROVAL IN WRITING.
PO BOX 271, Nortchote Plaza, Vic, 3070 | [email protected] | (03) 9484 8328
copyright of C. Kairouz Architects. prior written permission is necessary for reproduction.
C. KAIROUZ ARCHITECTSDATE:
SCALE:
JOB N :o
AMENDEMENT:PROJECT:
LOCATION:
CLIENT:
No in SET:
1 : 50
MITCHELL STREET
156 MITCHELL STREET, NORTHCOTE
STACEY & TONY
02.03.2018
CKA17-052A20
DetailNo. Description Date
1 : 50A061 Section CC
a0.pdf (p.1)a1.pdf (p.2)a2.pdf (p.3)a3.pdf (p.4)a4.pdf (p.5)a5.pdf (p.6)a6.pdf (p.7)a7.pdf (p.8)a8.pdf (p.9)a9.pdf (p.10)a10.pdf (p.11)a11.pdf (p.12)A12.pdf (p.13)A13.pdf (p.14)A14.pdf (p.15)A15.pdf (p.16)A16.pdf (p.17)A17.pdf (p.18)A18.pdf (p.19)A19.pdf (p.20)A20.pdf (p.21)