![Page 1: 2 Best solution for installing a few I/O points in a remote location Mixed I/O – 2UAI / 2AO / 4DI / 4DO – 6AO / 6DIO – 8AI / 2DIO Universal analog inputs](https://reader035.vdocument.in/reader035/viewer/2022062511/551c5a1a550346a5458b5178/html5/thumbnails/1.jpg)
![Page 2: 2 Best solution for installing a few I/O points in a remote location Mixed I/O – 2UAI / 2AO / 4DI / 4DO – 6AO / 6DIO – 8AI / 2DIO Universal analog inputs](https://reader035.vdocument.in/reader035/viewer/2022062511/551c5a1a550346a5458b5178/html5/thumbnails/2.jpg)
2
• Best solution for installing a few I/O points in a remote location
• Mixed I/O– 2UAI / 2AO / 4DI / 4DO– 6AO / 6DIO– 8AI / 2DIO
• Universal analog inputs allow conventional analog, thermocouple, and RTD in a single unit
• Connects over Ethernet to CTI 2572, 2572-A, 2500-Cxxx, 2500P-ECC1
• Uses CAMP to transfer I/O values directly to the CPU– Should be used for non-critical I/O, as CAMP is not an I/O optimized
protocol
• Includes options for long distance connection using 900Mhz radio (subject to import limitation, depending on countries) OR cellular
• Planned introduction beginning 2013
2500 Series® Slice I/OOverview
![Page 3: 2 Best solution for installing a few I/O points in a remote location Mixed I/O – 2UAI / 2AO / 4DI / 4DO – 6AO / 6DIO – 8AI / 2DIO Universal analog inputs](https://reader035.vdocument.in/reader035/viewer/2022062511/551c5a1a550346a5458b5178/html5/thumbnails/3.jpg)
3
• For DI– Configurable filtering & debounce– Totalization of counts and runtime– Rate measurement up to 10Khz
• For DO– PWM pulse function– Synchronized outputs
• For AI– Some models have Universal Inputs (UI), which allow current, voltage,
thermocouple, or RTD– Configurable filtering and averaging– Configurable totalization
• Data logging and trending• Configuration and monitoring using web interface
– Can also configure using the PLC
2500 Series® Slice I/OIntelligent Features
![Page 4: 2 Best solution for installing a few I/O points in a remote location Mixed I/O – 2UAI / 2AO / 4DI / 4DO – 6AO / 6DIO – 8AI / 2DIO Universal analog inputs](https://reader035.vdocument.in/reader035/viewer/2022062511/551c5a1a550346a5458b5178/html5/thumbnails/4.jpg)
4
2500 Series® Slice I/OTypical connections - wired
100Mb Cat5
100Mb Cat5
100Mb Cat5
100Mb Cat5
100M
b Fib
er 54Mb Wireless
100Mb Cat5
100Mb Cat5
![Page 5: 2 Best solution for installing a few I/O points in a remote location Mixed I/O – 2UAI / 2AO / 4DI / 4DO – 6AO / 6DIO – 8AI / 2DIO Universal analog inputs](https://reader035.vdocument.in/reader035/viewer/2022062511/551c5a1a550346a5458b5178/html5/thumbnails/5.jpg)
5
2500 Series® Slice I/OTypical connection – 900 Mhz wireless (subject to import limitation, depending on countries)
Range up to 64km / 40mi
![Page 6: 2 Best solution for installing a few I/O points in a remote location Mixed I/O – 2UAI / 2AO / 4DI / 4DO – 6AO / 6DIO – 8AI / 2DIO Universal analog inputs](https://reader035.vdocument.in/reader035/viewer/2022062511/551c5a1a550346a5458b5178/html5/thumbnails/6.jpg)
6
2500 Series® Slice I/OTypical connection – cellular wireless
cellular network
cellular network
![Page 7: 2 Best solution for installing a few I/O points in a remote location Mixed I/O – 2UAI / 2AO / 4DI / 4DO – 6AO / 6DIO – 8AI / 2DIO Universal analog inputs](https://reader035.vdocument.in/reader035/viewer/2022062511/551c5a1a550346a5458b5178/html5/thumbnails/7.jpg)
7
• Wired Ethernet– 2500S-23-1050 4DI / 4DO / 2UAI / 2AO– 2500S-26-1050 8DIO / 2UAI– 2500S-27-1050 2DIO / 4UAI / 2AI
• Wired Ethernet with RS232/485– 2500S-23-1550 4DI / 4DO / 2UAI / 2AO– 2500S-26-1550 8DIO / 2UAI– 2500S-27-1550 2DIO / 4UAI / 2AI
• Wired Ethernet and 900 Mhz Radio (subject to import limitation, depending on countries)– 2500S-23-1360 4DI / 4DO / 2UAI / 2AO– 2500S-26-1360 8DIO / 2UAI– 2500S-27-1360 2DIO / 4UAI / 2AI
2500 Series® Slice I/OModels