INDEX SHEET
200 / 300 SERIES PANELS
CI-DS-01-200/300 C & I DISCLAIMER
CI-PP-01-200 PANEL PROFILES 200 SERIES
CI-PP-02-300 PANEL PROFILES 300 SERIES
CI-PJ-01-200 200 EXPANDED PANEL JOINT
CI-PJ-02-200 200 ENGAGED PANEL JOINT
CI-PJ-03-300 300 EXPANDED PANEL JOINT
CI-PJ-04-300 300 ENGAGED PANEL JOINT
CI-PJ-05-200/300 INTERMEDIATE SUPPORT
CI-BS-01-200/300 BASE DETAIL - FLUSH
CI-BS-02-200/300 BASE DETAIL - NOTCHED CONCRETE
CI-BS-03-200/300 BASE DETAIL - OVERHANG W/ DRIP
CI-BS-04-200/300 BASE DETAIL - OVERHANG W/ SUPPORT
CI-BS-05-200/300 BASE DETAIL - MARRIAGE BEAD ISOMETRIC
CI-OC-01-200/300 OUTSIDE CORNER WITH PROFILED TRIM
CI-OC-02-200/300 OUTSIDE CORNER WITH FLAT TRIM
CI-IC-01-200/300 INSIDE CORNER WITH PROFILED TRIM
CI-IC-02-200/300 INSIDE CORNER WITH FLAT TRIM
CI-FO-01-200/300 F.O. HEAD WITH DRIP EDGE
CI-FO-02-200/300 F.O. TWO PIECE JAMB
CI-FO-03-200/300 F.O. ONE PIECE JAMB
CI-FO-04-200/300 F.O. ONE PIECE SILL
CI-FO-05-200/300 F.O. INTERIOR PARTITION
CI-FO-06-200/300 O.H. DOOR HEAD WITH DRIP EDGE
CI-FO-07-200/300 O.H. DOOR TWO PIECE JAMB
INDEX SHEET
200 / 300 SERIES PANELS
CI-SJ-01-200/300 STACK JOINT
CI-SJ-01-200/300 STACK JOINT - ALTERNATE
CI-PR-01-200/300 PARAPET WITH FLUSH TRIM
CI-PR-02-200/300 PARAPET WITH PROFILED TRIM
CI-WR-01-200/300 WALL TO ROOF
CI-WR-02-200/300 CONTINUOUS WALL AT ROOF / CANOPY
CI-PE-01-200/300 PIPE PENETRATION
CI-PE-02-200/300 PIPE PENETRATION ISOMETRIC
CI-PE-03-200/300 KNIFE PENETRATION
CI-PE-04-200/300 KNIFE PENETRATION ISOMETRIC
CI-PE-05-200/300 BEAM PENETRATION
CI-PE-06-200/300 BEAM PENETRATION ISOMETRIC
CI-TL-01-200/300 TRIM END LAP
CI-TL-02-200/300 TRIM END LAP WITH HEM
CI-TL-03-200/300 TRIM END LAP WITH LAP STRIP
CI-TL-04-200/300 TRIM LAP AT FRAMED OPENINGS -
ISOMETRIC
CI-TL-05-200/300 TRIM LAP AT FRAMED OPENINGS -
EXPLODED VIEW
200 / 300 SERIES PANELS
COMMERCIAL/INDUSTRIAL
DISCLAIMER
DISCLAIMER:
THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED
COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES.
LOCATION OF VAPOR BARRIERS AND ASSOCIATED SEALANTS IN THESE DETAILS ARE BASED
ON TYPICAL DESIGN PRACTICES FOR MOST U.S. CLIMACTIC ZONES. (THE PRIMARY VAPOR
BARRIER IS PLACED ON THE "WARM" SIDE IN WINTER).
PROJECTS LOCATED IN AREAS SUBJECT TO EXTREME COLD AND/OR HIGH SNOW LOADS MAY
REQUIRE MODIFICATIONS TO THESE DETAILS - CONTACT KINGSPAN TECHNICAL SERVICES
FOR SPECIFIC PROJECT RECOMMENDATIONS.
CORE DEPTHS:
2", 2.5", 3", 4", 5", 6"
42" COVERAGE (1,067mm)
2"-6"
42" COVERAGE (1,067mm)
2"-6"
42" COVERAGE (1,067mm)
200 SERIES PANEL (DELAND)
MINOR RIB
INVERTED RIB
SHADOWLINE
INVERTED RIB
"V" GROOVE
INVERTED RIB
2"-6"200 SERIES PANEL (MODESTO)
STEEL GAUGES:
EXTERIOR: 26, 24, 22
INTERIOR: 26, 24, 22
MODULE WIDTH: 42"
PANEL ORIENTATION: VERTICAL
EMBOSSING:
EXTERIOR: STUCCO / SMOOTH
INTERIOR: STUCCO / SMOOTH
LENGTHS:
MINIMUM: 8'-0"
MAXIMUM: 53'-0"
200 SERIES PANEL (MODESTO)
EXTERIOR
INTERIOR
EXTERIOR
INTERIOR
EXTERIOR
INTERIOR
200 / 300 SERIES PANELS
PANEL PROFILES
200 SERIES
2"-6"
42" COVERAGE (1,067mm)
300SL SERIES PANEL (DELAND)
MINOR RIB
2"-6"
42" COVERAGE (1,067mm)
300MR SERIES PANEL (DELAND)
MICRO-RIB
2"-6"
42" COVERAGE (1,067mm)
300SR SERIES PANEL (MODESTO)
STRIATED
2"-6"
42" COVERAGE (1,067mm)
300A SERIES PANEL (DELAND)
SHADOWLINE, MINOR RIB, V-GROOVE
AZTECO
CORE DEPTHS:
DELAND: 2", 2.5", 3", 4", 5", 6"
STEEL GAUGES:
EXTERIOR: 26, 24, 22
INTERIOR: 26, 24, 22
MODULE WIDTH: 42"
PANEL ORIENTATION: VERTICAL
EMBOSSING:
EXTERIOR: STUCCO / SMOOTH
INTERIOR: STUCCO / SMOOTH
LENGTHS:
MINIMUM: 8'-0"
MAXIMUM: 53'-0"
EXTERIOR
INTERIOR
EXTERIOR
INTERIOR
EXTERIOR
INTERIOR
SHADOWLINE, MINOR RIB, V-GROOVE
SHADOWLINE, MINOR RIB, V-GROOVE
SHADOWLINE, MINOR RIB, V-GROOVE
EXTERIOR
INTERIOR
200 / 300 SERIES PANELS
PANEL PROFILES
300 SERIES
WALL PANEL INSTALLATION DIRECTION
14 GA. GALVANIZED
2-HOLE HIDDEN CLIP
(1 PER PANEL, PER SUPPORT)
SET CLIP IN BUTYL SEALANT
(2)-
1
4
" HEX HEAD
FASTENERS PER PANEL CLIP
CONTINUOUS
BUTYL SEALANT
HORIZONTAL SUPPORT
(NOT BY KINGSPAN)
CONTINUOUS BUTYL
SEALANT (OPTIONAL)
MALE LEG FEMALE POCKET
MALE LEG
FEMALE POCKET
NOTE: FILL FEMALE POCKET(S) 3/4 FULL WITH SEALANT TO PROVIDE PROPER AIR/WATER SEAL
200 / 300 SERIES PANELS
200 EXPANDED
PANEL JOINT
WALL PANEL INSTALLATION DIRECTION
CONTINUOUS BUTYL SEALANT
(2)-
1
4
" HEX HEAD
FASTENERS PER PANEL CLIP
HORIZONTAL SUPPORT
(NOT BY KINGSPAN)
CONTINUOUS BUTYL
SEALANT (OPTIONAL)
14 GA. GALVANIZED
2-HOLE HIDDEN CLIP
(1 PER PANEL, PER SUPPORT)
SET CLIP IN BUTYL SEALANT
200 / 300 SERIES PANELS
200 ENGAGED
PANEL JOINT
WALL PANEL INSTALLATION DIRECTION
CONTINUOUS
BUTYL SEALANT
MALE LEG FEMALE POCKET
MALE LEG
FEMALE POCKET
NOTE: FILL FEMALE POCKET(S) 3/4 FULL WITH SEALANT TO PROVIDE PROPER AIR/WATER SEAL
(2)-
1
4
" HEX HEAD
FASTENERS PER PANEL CLIP
14 GA. GALVANIZED 2-HOLE
HIDDEN CLIP
(1 PER PANEL, PER SUPPORT)
SET CLIP IN BUTYL SEALANT
HORIZONTAL SUPPORT
(NOT BY KINGSPAN)
CONTINUOUS BUTYL
SEALANT (OPTIONAL)
200 / 300 SERIES PANELS
300 EXPANDED
PANEL JOINT
FEMALE JOINT MALE JOINT
WALL PANEL INSTALLATION DIRECTION
(2) -
1
4
" HEX HEAD
FASTENERS PER PANEL CLIP
CONTINUOUS BUTYL SEALANT
14 GA. GALVANIZED 2-HOLE
HIDDEN CLIP
(1 PER PANEL, PER SUPPORT)
SET CLIP IN BUTYL SEALANT
HORIZONTAL SUPPORT
(NOT BY KINGSPAN)
CONTINUOUS BUTYL
SEALANT (OPTIONAL)
200 / 300 SERIES PANELS
300 ENGAGED
PANEL JOINT
(2) -
1
4
" HEX HEAD FASTENERS
PER PANEL CLIP
1
4
5
°
3"
.75 .75
Ø 0.28"
.7
2
14 GA. GALVANIZED 2-HOLE HIDDEN CLIP
CONTINUOUS BUTYL
SEALANT AT PANEL JOINT
14 GA. GALVANIZED
2-HOLE HIDDEN CLIP
(1 PER PANEL, PER SUPPORT)
SET CLIP IN BUTYL SEALANT
HORIZONTAL SUPPORT
(NOT BY KINGSPAN)
1 .50"
.3
6
200 / 300 SERIES PANELS
INTERMEDIATE
SUPPORT
BASE TRIM
FASTENER TO CONCRETE
(NOT BY KINGSPAN)
POP RIVETS @
8" O.C.
BASE FLASHING SET
IN CONTINUOUS BED
OF BUTYL SEALANT
NOTE: SEE DETAIL CI-TL-01-200/300 AND CI-TL-02-200/300 FOR TYPICAL
TRIM LAP INSTRUCTIONS
14 GA. GALVANIZED
2-HOLE HIDDEN CLIP
(1 PER PANEL, PER GIRT)
SET CLIP IN BUTYL
SEALANT
CONTINUOUS BUTYL SEALANT W/
MARRIAGE BEAD TO VERTICAL
PANEL JOINT
(2)-
1
4
" HEX HEAD
FASTENERS PER PANEL CLIP
MIN 16 GA. GALVANIZED
BASE ANGLE WITH MINIMUM 3"
BEARING SURFACE FOR PANEL
FASTENING (NOT BY KINGSPAN)
CONTINUOUS BUTYL
SEALANT AT PANEL JOINT
SET ANGLE IN BED OF SEALANT
(NOT BY KINGSPAN)
200 / 300 SERIES PANELS
BASE DETAIL - FLUSH
BASE TRIM
1
1
2
"
(T
YP
.)
NOTE: SEE DETAIL CI-TL-01-200/300 AND CI-TL-02-200/300 FOR TYPICAL
TRIM LAP INSTRUCTIONS
POP RIVETS @
8" O.C.
14 GA. GALVANIZED
2-HOLE HIDDEN CLIP
(1 PER PANEL, PER GIRT)
SET CLIP IN BUTYL
SEALANT
BASE FLASHING SET
IN CONTINUOUS BED
OF BUTYL SEALANT
FASTENER TO CONCRETE
(NOT BY KINGSPAN)
CONTINUOUS BUTYL SEALANT W/
MARRIAGE BEAD TO VERTICAL
PANEL JOINT
(2)-
1
4
" HEX HEAD
FASTENERS PER PANEL CLIP
MIN 16 GA. GALVANIZED
BASE ANGLE WITH MINIMUM 3"
BEARING SURFACE FOR PANEL
FASTENING (NOT BY KINGSPAN)
CONTINUOUS BUTYL
SEALANT AT PANEL JOINT
SET ANGLE IN BED OF SEALANT
(NOT BY KINGSPAN)
200 / 300 SERIES PANELS
BASE DETAIL - NOTCHED
CONCRETE
BASE TRIM
1
1
2
"
(T
YP
.)
NOTE: SEE DETAIL CI-TL-01-200/300 AND CI-TL-02-200/300 FOR TYPICAL
TRIM LAP INSTRUCTIONS
BASE FLASHING
POP RIVETS @
8" O.C.
14 GA. GALVANIZED
2-HOLE HIDDEN CLIP
(1 PER PANEL, PER GIRT)
SET CLIP IN BUTYL
SEALANT
CONTINUOUS BUTYL SEALANT W/
MARRIAGE BEAD TO VERTICAL
PANEL JOINT
(2)-
1
4
" HEX HEAD
FASTENERS PER PANEL CLIP
MIN 16 GA. GALVANIZED
BASE ANGLE WITH MINIMUM 3"
BEARING SURFACE FOR PANEL
FASTENING (NOT BY KINGSPAN)
CONTINUOUS BUTYL
SEALANT AT PANEL JOINT
SET ANGLE IN BED OF SEALANT
(NOT BY KINGSPAN)
FASTENER TO CONCRETE
(NOT BY KINGSPAN)
200 / 300 SERIES PANELS
BASE DETAIL -
OVERHANG W/ DRIP
BASE TRIM
1
1
2
"
(T
YP
.)
NOTE: SEE DETAIL CI-TL-01-200/300 AND CI-TL-02-200/300 FOR TYPICAL
TRIM LAP INSTRUCTIONS
POP RIVETS @
8" O.C.
14 GA. GALVANIZED
2-HOLE HIDDEN CLIP
(1 PER PANEL, PER GIRT)
SET CLIP IN BUTYL
SEALANT
SET ANGLE IN BED OF SEALANT
(NOT BY KINGSPAN)
FASTENER TO CONCRETE
(NOT BY KINGSPAN)
BASE FLASHING SET
IN CONTINUOUS BED
OF BUTYL SEALANT
CONTINUOUS BUTYL SEALANT W/
MARRIAGE BEAD TO VERTICAL
PANEL JOINT
(2)-
1
4
" HEX HEAD
FASTENERS PER PANEL CLIP
MIN 16 GA. GALVANIZED
BASE ANGLE WITH MINIMUM 3"
BEARING SURFACE FOR PANEL
FASTENING (NOT BY KINGSPAN)
CONTINUOUS BUTYL
SEALANT AT PANEL JOINT
200 / 300 SERIES PANELS
BASE DETAIL -
OVERHANG W/
OPTIONAL SUPPORT
NOTE:
ENSURE THERE ARE NO
GAPS IN SEALANT BEAD.
COVERAGE MUST BE
CONTINUOUS
MARRIAGE BEAD TO VERTICAL JOINT
(FEMAILE INTERIOR JOINT TO HAVE EITHER
FACTORY OR FIELD CONTINUOUS BUTYL
SEALANT)
BASE FLASHING
CONTINUOUS HEAVY BEAD
OF BUTYL SEALANT
PANEL CLIP TO BE SET IN BED OF BUTYL
SEALANT
14 GA. GALVANIZED 2-HOLE
HIDDEN CLIP
(1 PER PANEL, PER SUPPORT)
MIN 16 GA. GALVANIZED
BASE ANGLE SET IN BED OF
SEALANT (NOT BY KINGSPAN)
200 / 300 SERIES PANELS
BASE DETAIL -
MARRIAGE BEAD
ISOMETRIC
OUTSIDE CORNER TRIM
POP RIVETS @
8" O.C.
3
4
" PHIL. PAN HEAD @ 8" O.C.
INSIDE CORNER TRIM
CONTINUOUS
BUTYL SEALANT
WIL
L V
AR
Y W
IT
H
FIE
LD
C
ON
DIT
IO
N
WILL VARY WITH
FIELD CONDITION
FIELD CUT
HORIZONTAL SUPPORT
(NOT BY KINGSPAN)
EXPANDABLE
INSULATION AS REQUIRED
(NOT BY KINGSPAN)
1
4
" - THROUGH FASTENERS
W/ 1
1
8
" BONDED WASHER
(AS REQUIRED FOR WIND LOAD)
ATTACHMENT CLIP
(NOT BY KINGSPAN)
CONTINUOUS
BUTYL TAPE / SEALANT
CONTINUOUS
BUTYL TAPE /
SEALANT
3
4
" PHIL. PAN HEAD @ 8" O.C.
1
4
" - THROUGH FASTENERS W/
1
1
8
" BONDED WASHER (AS
REQUIRED FOR WIND LOAD)
200 / 300 SERIES PANELS
OUTSIDE CORNER
WITH PROFILED TRIM
WIL
L V
AR
Y W
IT
H
FIE
LD
C
ON
DIT
IO
N
WILL VARY WITH
FIELD CONDITION
FIELD CUT
OUTSIDE CORNER TRIM
POP RIVETS @
8" O.C.
3
4
" PHIL. PAN HEAD @ 8" O.C.
INSIDE CORNER TRIM
CONTINUOUS
BUTYL SEALANT
HORIZONTAL SUPPORT
(NOT BY KINGSPAN)
F.I.P. INSULATION
AS REQUIRED
(BY OTHERS)
ATTACHMENT CLIP
(NOT BY KINGSPAN)
CONTINUOUS
BUTYL TAPE / SEALANT
CONTINUOUS
BUTYL TAPE /
SEALANT
3
4
" PHIL. PAN HEAD @ 8" O.C.
1
4
" - "LOW PROFILE"
THROUGH FASTENER
W/ 1
1
8
" BONDED WASHER
(AS REQUIRED FOR WIND LOAD)
1
4
" - "LOW PROFILE" THROUGH
FASTENER W/ 1
1
8
" BONDED
WASHER (AS REQUIRED FOR
WIND LOAD)
200 / 300 SERIES PANELS
OUTSIDE CORNER
WITH FLAT TRIM
3
4
" PHIL. PAN HEAD
@ 8" O.C.
OUTSIDE CORNER TRIM
HORIZONTAL SUPPORT
(NOT BY KINGSPAN)
POP RIVETS
8" O.C.
EXPANDABLE
INSULATION AS REQUIRED
(NOT BY KINGSPAN)
1
4
" - THROUGH FASTENERS
W/ 1
1
8
" BONDED WASHER
(AS REQUIRED FOR WIND
LOAD)
CONTINUOUS BUTYL
SEALANT
CONTINUOUS
BUTYL SEALANT
3
4
" PHIL. PAN HEAD
@ 8" O.C.
CONTINUOUS BUTYL
SEALANT
WIL
L V
AR
Y W
IT
H
FIE
LD
C
ON
DIT
IO
N
WILL VARY WITH
FIELD CONDITION
FIELD CUT
CONTINUOUS BUTYL
SEALANT
INSIDE CORNER TRIM
POP RIVETS
8" O.C.
1
4
" - THROUGH
FASTENERS W/ 1
1
8
"
BONDED WASHER (AS
REQUIRED FOR WIND
LOAD)
200 / 300 SERIES PANELS
INSIDE CORNER
WITH PROFILED TRIM
WIL
L V
AR
Y W
IT
H
FIE
LD
C
ON
DIT
IO
N
WILL VARY WITH
FIELD CONDITION
FIELD CUT
3
4
" PHIL. PAN HEAD
@ 8" O.C.
OUTSIDE CORNER TRIM
HORIZONTAL SUPPORT
(NOT BY KINGSPAN)
POP RIVETS
8" O.C.
CONTINUOUS BUTYL
SEALANT
CONTINUOUS
BUTYL SEALANT
3
4
" PHIL. PAN HEAD
@ 8" O.C.
CONTINUOUS BUTYL
SEALANT
CONTINUOUS BUTYL
SEALANT
INSIDE CORNER TRIM
POP RIVETS
8" O.C.
1
4
" - "LOW PROFILE"
THROUGH FASTENER
W/ 1
1
8
" BONDED WASHER
(AS REQUIRED FOR WIND
LOAD)
1
4
" - "LOW PROFILE"
THROUGH FASTENER
W/ 1
1
8
" BONDED WASHER
(AS REQUIRED FOR WIND
LOAD)
EXPANDABLE
INSULATION AS REQUIRED
(NOT BY KINGSPAN)
200 / 300 SERIES PANELS
INSIDE CORNER
WITH FLAT TRIM
EXTERIOR CAP TRIM
1
4
" - "LOW PROFILE"
THROUGH FASTENER
@ 12" O.C.
EXPOSED SEALANT
(NOT BY KINGSPAN)
DRIP FLASHING
FRAMED OPENING
(NOT BY KINGSPAN)
DOOR/WINDOW FRAME
(NOT BY KINGSPAN)
CONTINUOUS BUTYL SEALANT
BOTH SIDES OF TRIM W/
MARRIAGE BEAD TO VERTICAL
PANEL JOINT
NOTE: SEE DETAIL CI-TL-01-200/300, CI-TL-02-200/300, AND CI-TL-04-200/300
FOR TYPICAL TRIM LAP INSTRUCTIONS
CONTINUOUS BUTYL
SEALANT AT PANEL JOINT
POP RIVETS
8" O.C.
200 / 300 SERIES PANELS
FRAMED OPENING
HEAD W/ "DRIP EDGE"
INTERIOR CAP TRIM
1
4
" - "LOW PROFILE"
THROUGH FASTENER
@ 12" O.C.
CONTINUOUS BUTYL SEALANT
BOTH SIDES OF TRIM
FRAMED OPENING
(NOT BY KINGSPAN)
EXTERIOR CAP TRIM
DOOR/WINDOW FRAME
(NOT BY KINGSPAN)
EXPOSED SEALANT
(NOT BY KINGSPAN)
NOTE: SEE DETAIL CI-TL-01-200/300, CI-TL-02-200/300, AND CI-TL-04-200/300
FOR TYPICAL TRIM LAP INSTRUCTIONS
POP RIVETS
8" O.C.
POP RIVETS 8" O.C.
CONTINUOUS BUTYL
SEALANT
CONTINUOUS BUTYL SEALANT
200 / 300 SERIES PANELS
FRAMED OPENING
TWO PIECE JAMB
FRAMED OPENING
(NOT BY KINGSPAN)
DOOR/WINDOW FRAME
(NOT BY KINGSPAN)
EXPOSED SEALANT
(NOT BY KINGSPAN)
1
4
" - "LOW PROFILE"
THROUGH FASTENER
WASHER @ 12" O.C.
CONTINUOUS BUTYL SEALANT
1
4
" - 14 "LOW PROFILE"
FASTENER (AS REQUIRED)
NOTE: SEE DETAIL CI-TL-01-200/300, CI-TL-02-200/300, AND CI-TL-04-200/300
FOR TYPICAL TRIM LAP INSTRUCTIONS
CONTINUOUS BUTYL SEALANT
CAP TRIM
POP RIVETS 8" O.C.
CONTINUOUS BUTYL SEALANT
200 / 300 SERIES PANELS
FRAMED OPENING
ONE PIECE JAMB
EXTERIOR CAP TRIM,
SLOPE TRIM FOR POSITIVE
DRAINAGE. SLOPE AND SIZE OF
TRIM TO BE DETERMINED BY
OTHERS (NOT BY KINGSPAN)
1
4
" - "LOW PROFILE"
THROUGH FASTENER
@ 12" O.C.
FRAMED OPENING
(NOT BY KINGSPAN)
DOOR/WINDOW FRAME
(NOT BY KINGSPAN)
EXPOSED SEALANT
(NOT BY KINGSPAN)
CONTINUOUS BUTYL SEALANT
W/ MARRIAGE BEAD TO
VERTICAL PANEL JOINT
1
4
" - "LOW PROFILE"
FASTENER (AS
REQUIRED)
CONTINUOUS BUTYL
SEALANT
NOTE: SEE DETAIL CI-TL-01-200/300, CI-TL-02-200/300, AND CI-TL-04-200/300
FOR TYPICAL TRIM LAP INSTRUCTIONS
CONTINUOUS BUTYL
SEALANT AT PANEL JOINT
SLO
PE
POP RIVETS
8" O.C.
FIELD CUT PANEL TO SLOPE
(NOT BY KINGSPAN)
200 / 300 SERIES PANELS
FRAMED OPENING
ONE PIECE SILL
CAP TRIM
CONTINUOUS BUTYL SEALANT
CAP TRIM
CONTINUOUS BUTYL SEALANT
CONTRACTOR MAY REMOVE A PORTION
OF THE FOAM CORE AND INSERT TREATED
LUMBER TO REINFORCE LARGE OPENINGS
CAP TRIM
CONTRACTOR MAY REMOVE A PORTION
OF THE FOAM CORE AND INSERT TREATED
LUMBER TO REINFORCE LARGE OPENINGS
DOOR CASING
(NOT BY KINGSPAN)
THROUGH BOLT AS
REQUIRED FOR ATTACHMENT
OF DOOR CASING
(NOT BY KINGSPAN)
CONTINUOUS
BUTYL SEALANT
3
4
" PHIL. PAN HEAD
3
4
" PHIL. PAN HEAD
DOOR CASING
(NOT BY KINGSPAN)
200 / 300 SERIES PANELS
FRAMED OPENING
PARTITION
EXTERIOR CAP TRIM
DRIP FLASHING
FRAMED OPENING
(NOT BY KINGSPAN)
CONTINUOUS BUTYL SEALANT
W/ MARRIAGE BEAD TO
VERTICAL PANEL JOINT
FASTENER
(NOT BY KINGSPAN)
NOTE: SEE DETAIL CI-TL-01-200/300, CI-TL-02-200/300, AND CI-TL-04-200/300
FOR TYPICAL TRIM LAP INSTRUCTIONS
HEADER TRIM
(OPTIONAL)
TRIM INSTALLATION SEQUENCE:
1 HEADER TRIM (OPTIONAL) & ALL APPLICABLE SEALANTS
2 DRIP FLASHING & ALL APPLICABLE SEALANTS PRIOR TO
INSTALLING THE PANEL AND THROUGH FASTENERS
3 EXTERIOR CAP TRIM
1
2
3
1
4
" - "LOW PROFILE"
THROUGH FASTENER
@ 12" O.C.
EXPOSED SEALANT
(NOT BY KINGSPAN)
POP RIVETS
8" O.C.
200 / 300 SERIES PANELS
OVERHEAD DOOR
HEAD W/ DRIP EDGE
INTERIOR CAP TRIM
1
4
" - "LOW PROFILE"
THROUGH FASTENER
@ 12" O.C.
CONTINUOUS BUTYL SEALANT
BOTH SIDES OF TRIM
FRAMED OPENING
(NOT BY KINGSPAN)
EXTERIOR CAP TRIM
EXPOSED SEALANT
(NOT BY KINGSPAN)
FASTENER
(NOT BY KINGSPAN)
JAMB TRIM
(OPTIONAL)
NOTE: SEE DETAIL CI-TL-01-200/300, CI-TL-02-200/300, AND CI-TL-04-200/300
FOR TYPICAL TRIM LAP INSTRUCTIONS
TRIM INSTALLATION SEQUENCE:
1 JAMB TRIM (OPTIONAL) & ALL APPLICABLE SEALANTS
2 INTERIOR CAP TRIM & ALL APPLICABLE SEALANTS PRIOR TO
INSTALLING THE PANEL AND THROUGH FASTENERS
3 EXTERIOR CAP TRIM
1
2
3
POP RIVETS 8" O.C.
POP RIVETS
8" O.C. (UNLESS NOTED OTHERWISE)
CONTINUOUS BUTYL
SEALANT
CONTINUOUS BUTYL SEALANT
200 / 300 SERIES PANELS
OVERHEAD DOOR
TWO-PIECE JAMB
STACK TRIM
HORIZONTAL SUPPORT
(NOT BY KINGSPAN)
CONTINUOUS 3" X 3" ANGLE
(GAUGE TO MATCH GIRT)
(NOT BY KINGSPAN)
POP RIVETS
8" O.C.
STACK FLASHING
CONTINUOUS BUTYL
SEALANT BELOW BASE
FLASHING
CONTINUOUS BUTYL SEALANT W/
MARRIAGE BEAD TO VERTICAL
PANEL JOINT
CONTINUOUS BUTYL SEALANT W/
MARRIAGE BEAD TO VERTICAL
PANEL JOINT
FASTEN AS REQUIRED
(NOT BY KINGSPAN)
CONTINUOUS BUTYL
SEALANT AT PANEL JOINT
MIN 16 GA. GALVANIZED
BASE ANGLE SET IN BED OF
SEALANT (NOT BY KINGSPAN)
14 GA. GALVANIZED
2-HOLE HIDDEN CLIP
(1 PER PANEL, PER GIRT)
SET CLIP IN BUTYL
SEALANT
14 GA. GALVANIZED
2-HOLE HIDDEN CLIP
(1 PER PANEL, PER GIRT)
SET CLIP IN BUTYL
SEALANT
(2)-
1
4
" HEX HEAD
FASTENERS PER PANEL CLIP
200 / 300 SERIES PANELS
STACK JOINT
STACK TRIM
HORIZONTAL SUPPORT
(NOT BY KINGSPAN)
CONTINUOUS 3" X 3" ANGLE
(GAUGE TO MATCH GIRT)
(NOT BY KINGSPAN)
POP RIVETS
8" O.C.
STACK FLASHING
CONTINUOUS BUTYL
SEALANT BELOW BASE
FLASHING
CONTINUOUS BUTYL SEALANT W/
MARRIAGE BEAD TO VERTICAL
PANEL JOINT
CONTINUOUS BUTYL SEALANT W/
MARRIAGE BEAD TO VERTICAL
PANEL JOINT
FASTEN AS REQUIRED
(NOT BY KINGSPAN)
CONTINUOUS BUTYL
SEALANT AT PANEL JOINT
MIN 16 GA. GALVANIZED
BASE ANGLE SET IN BED OF
SEALANT (NOT BY KINGSPAN)
14 GA. GALVANIZED
2-HOLE HIDDEN CLIP
(1 PER PANEL, PER GIRT)
SET CLIP IN BUTYL
SEALANT
14 GA. GALVANIZED
2-HOLE HIDDEN CLIP
(1 PER PANEL, PER GIRT)
SET CLIP IN BUTYL
SEALANT
(2)-
1
4
" HEX HEAD
FASTENERS PER PANEL CLIP
200 / 300 SERIES PANELS
STACK JOINT
ALTERNATE
CONTINUOUS CLEAT
MEMBRANE,PARAPET
BLOCKING AND ACCESSORIES
(NOT BY KINGSPAN)
MEMBRANE ROOF &
PARAPET BACKER
(NOT BY KINGSPAN)
FASTENER TO PARAPET
BACKER (NOT BY KINGSPAN)
PARAPET CAP
1
4
" - "LOW PROFILE"
FASTENER @ 8" O.C.
CONTINUOUS BUTYL
SEALANT AT PANEL JOINT
CONTINUOUS BUTYL SEALANT W/
MARRIAGE BEAD TO FACE OF PANEL
14 GA. GALVANIZED
2-HOLE HIDDEN CLIP
(1 PER PANEL, PER GIRT)
SET CLIP IN BUTYL
SEALANT
(2) -
1
4
" HEX HEAD
FASTENERS PER PANEL CLIP
200 / 300 SERIES PANELS
PARAPET
WITH FLUSH TRIM
POP RIVETS
8" O.C.
PARAPET BACKER
(NOT BY KINGSPAN)
FASTENER TO PARAPET
BACKER
(NOT BY KINGSPAN)
PARAPET CAP
WRAP MEMBRANE,PARAPET
BLOCKING AND ACCESSORIES
(NOT BY KINGSPAN)
CONTINUOUS BUTYL
SEALANT AT PANEL JOINT
14 GA. GALVANIZED
2-HOLE HIDDEN CLIP
(1 PER PANEL, PER GIRT)
SET CLIP IN BUTYL
SEALANT
(2) -
1
4
" HEX HEAD
FASTENERS PER PANEL CLIP
CONTINUOUS BUTYL SEALANT W/
MARRIAGE BEAD TO FACE OF PANEL
200 / 300 SERIES PANELS
PARAPET
WITH PROFILED TRIM
CONTINUOUS BUTYL
SEALANT W/ MARRIAGE
BEAD TO VERTICAL JOINT
(2)
1
4
" - 14 HEX
HEAD FASTENERS
PER CLIP
BASE TRIM W/ POP RIVETS
@ 8" O.C.
MEMBRANE ROOF AND
ACCESSORIES
(NOT BY KINGSPAN
FLAT STOCK MATERIAL
(FIELD BREAK BY OTHERS)
BASE FLASHING
BASE FLASHING
14 GA. GALVANIZED
2-HOLE HIDDEN CLIP
(1 PER PANEL, PER GIRT)
SET CLIP IN BUTYL
SEALANT
200 / 300 SERIES PANELS
WALL TO ROOF
CONTINUOUS BUTYL
SEALANT W/
MARRIAGE BEAD TO
VERTICAL JOINT
(2)
1
4
" - 14 HEX HEAD
FASTENERS PER
CLIP
14 GA. HIDDEN FASTENER
CLIP
(1 PER PANEL, PER GIRT)
BASE TRIM W/ POP RIVETS
MEMBRANE ROOF,
FRAMING AND
ACCESSORIES
(NOT BY KINGSPAN)
BASE FLASHING
(2)
1
4
" - 14 HEX HEAD
FASTENERS PER
CLIP
CONTINUOUS BUTYL
SEALANT IN INTERIOR
JOINT
14 GA. HIDDEN FASTENER
CLIP
(1 PER PANEL, PER GIRT)
CONTINUOUS BUTYL
SEALANT W/ MARRIAGE
BEAD TO EXTERIOR
VERTICAL JOINT
MIN
6
"
CONTINUOUS BUTYL
SEALANT IN INTERIOR
JOINT
MEMBRANE
(NOT BY KINGSPAN)
SUPPORT
(NOT BY KINGSPAN)
SUPPORT
(NOT BY KINGSPAN)
200 / 300 SERIES PANELS
CONTINUOUS WALL TO
ROOF/ CANOPY
FASTENER AS REQUIRED
SEALANT (NOT BY KINGSPAN)
2PC. FLASHING AS REQUIRED
(FIELD FABRICATED FROM
FLATSTOCK)
EXPANDABLE INSULATION
(NOT BY KINGSPAN)
SEALANT (NOT BY KINGSPAN)
SEALANT
(NOT BY KINGSPAN)
2 PC. FLASHING AS REQUIRED
FASTENER AS REQUIRED
SEALANT (NOT BY KINGSPAN)
FASTENER AS REQUIRED
FASTENER AS REQUIRED
NOTE: FLASHING AT PIPE PENETRATIONS
TO BE FIELD FABRICATED FROM FLATSTOCK
SHEETS AS NECESSARY. QUANTITY OF
FLATSTOCK REQUIRED SHALL BE PROVIDED
(NOT BY KINGSPAN)
NOTE:
DO NOT ALIGN PENETRATIONS
AT PANEL JOINT LOCATIONS.
EXPANDABLE INSULATION
(NOT BY KINGSPAN)
200 / 300 SERIES PANELS
PIPE PENETRATION
SECTION
INSULATED PANEL
SILICONE SEALANT
AT TOP OF FLASHING
(NOT BY KINGSPAN)
POP RIVETS
(QUANTITY REQUIRED SHALL
BE DETERMINED BY INSTALLER)
SILICONE SEALANT AT
PERIMETER OF PIPE
(NOT BY KINGSPAN)
TWO PIECE FLASHING
WITH
1
2
" HEM. BED
SEAL TO PANEL WITH
BUTYL SEALANT (BLIND)
COPE FLASHING (FIELD
FABRICATED FROM
FLATSTOCK)
NOTE:
THIS DETAIL ASSUMES
PENETRATION OCCURS
AFTER PANEL IS INSTALLED
PIPE PENETRATION
(NOT BY KINGSPAN)
NOTE:
DO NOT ALIGN PENETRATIONS
AT PANEL JOINT LOCATIONS.
SILICONE SEALANT
BETWEEN FLASHINGS
(NOT BY KINGSPAN)
NOTE: FLASHING AT PENETRATIONS
TO BE FIELD FABRICATED FROM FLATSTOCK
SHEETS AS NECESSARY. QUANTITY OF
FLATSTOCK REQUIRED SHALL BE DETERMINED BY INSTALLER
(NOT BY KINGSPAN)
200 / 300 SERIES PANELS
PIPE PENETRATION
ISOMETRIC
INSULATED PANEL
NOTE: THIS DETAIL ASSUMES
PENETRATION OCCURS
AFTER PANEL IS INSTALLED
SILICONE SEALANT
AT TOP OF FLASHING
(NOT BY KINGSPAN)
POP RIVETS
(QUANTITY REQUIRED SHALL
BE DETERMINED BY INSTALLER)
TWO PIECE FLASHING
WITH
1
2
" HEM. BED
SEAL TO PANEL WITH
BUTYL SEALANT (BLIND)
COPE FLASHING
(NOT BY KINGSPAN)
SILICONE SEALANT
BETWEEN FLASHINGS
(NOT BY KINGSPAN)
KNIFE PENETRATION
(NOT BY KINGSPAN)
SILICONE SEALANT AT
PERIMETER OF KNIFE
(NOT BY KINGSPAN)
INSULATED PANEL
POP RIVETS
SILICONE SEALANT
AT TOP OF FLASHING
(NOT BY KINGSPAN)
KNIFE PENETRATION
SILICONE SEALANT AT
PERIMETER OF KNIFE
(NOT BY KINGSPAN)
FILL VOID WITH F.I.P
INSULATION
(NOT BY KINGSPAN)
NOTE: FLASHING AT PENETRATIONS
TO BE FIELD FABRICATED FROM FLATSTOCK
SHEETS AS NECESSARY. QUANTITY OF
FLATSTOCK REQUIRED SHALL BE DETERMINED
BY INSTALLER
(NOT BY KINGSPAN)
200 / 300 SERIES PANELS
KNIFE PENETRATION
DETAIL
INSULATED PANEL
SILICONE SEALANT
AT TOP OF FLASHING
(NOT BY KINGSPAN)
SILICONE SEALANT AT
PERIMETER OF KNIFE
(NOT BY KINGSPAN)
TWO PIECE FLASHING
WITH
1
2
" HEM. BED
SEAL TO PANEL WITH
BUTYL SEALANT (BLIND)
COPE FLASHING
(NOT BY KINGSPAN)
SILICONE SEALANT
BETWEEN FLASHINGS
(NOT BY KINGSPAN)
NOTE: THIS DETAIL ASSUMES
PENETRATION OCCURS
AFTER PANEL IS INSTALLED
KNIFE PENETRATION
(NOT BY KINGSPAN)
POP RIVETS
(QUANTITY REQUIRED
SHALL BE DETERMINED
BY INSTALLER)
NOTE: FLASHING AT PENETRATIONS
TO BE FIELD FABRICATED FROM FLATSTOCK
SHEETS AS NECESSARY. QUANTITY OF
FLATSTOCK REQUIRED SHALL BE DETERMINED
BY INSTALLER
(NOT BY KINGSPAN)
200 / 300 SERIES PANELS
KNIFE PENETRATION
ISOMETRIC
NOTE: THIS DETAIL ASSUMES
PENETRATION OCCURS
AFTER PANEL IS INSTALLED
INSULATED PANEL
POP RIVETS
SILICONE SEALANT
AT TOP OF FLASHING
(NOT BY KINGSPAN)
BEAM PENETRATION
SILICONE SEALANT AT
PERIMETER OF BEAM
(NOT BY KINGSPAN)
FILL VOID WITH F.I.P
INSULATION
(NOT BY KINGSPAN)
INSULATED PANEL
SILICONE SEALANT
AT TOP OF FLASHING
(NOT BY KINGSPAN)
TWO PIECE FLASHING
WITH
1
2
" HEM. BED
SEAL TO PANEL WITH
BUTYL SEALANT (BLIND)
COPE FLASHING
(NOT BY KINGSPAN)
BEAM PENETRATION
(NOT BY KINGSPAN)
SILICONE SEALANT AT
PERIMETER OF BEAM
(NOT BY KINGSPAN)
NOTE: FLASHING AT PENETRATIONS
TO BE FIELD FABRICATED FROM FLATSTOCK
SHEETS AS NECESSARY. QUANTITY OF
FLATSTOCK REQUIRED SHALL BE DETERMINED
BY INSTALLER
(NOT BY KINGSPAN)
POP RIVETS
(QUANTITY REQUIRED
SHALL BE DETERMINED
BY INSTALLER)
SILICONE SEALANT
BETWEEN FLASHINGS
(NOT BY KINGSPAN)
200 / 300 SERIES PANELS
BEAM PENETRATION
DETAIL
NOTE: THIS DETAIL ASSUMES
PENETRATION OCCURS
AFTER PANEL IS INSTALLED
INSULATED PANEL
SILICONE SEALANT
AT TOP OF FLASHING
(NOT BY KINGSPAN)
SILICONE SEALANT AT
PERIMETER OF BEAM
(NOT BY KINGSPAN)
TWO PIECE FLASHING
WITH
1
2
" HEM. BED
SEAL TO PANEL WITH
BUTYL SEALANT (BLIND)
COPE FLASHING
(NOT BY KINGSPAN)
SILICONE SEALANT
BETWEEN FLASHINGS
(NOT BY KINGSPAN)
BEAM PENETRATION
(NOT BY KINGSPAN)
NOTE: FLASHING AT PENETRATIONS
TO BE FIELD FABRICATED FROM FLATSTOCK
SHEETS AS NECESSARY. QUANTITY OF
FLATSTOCK REQUIRED SHALL BE DETERMINED
BY INSTALLER
(NOT BY KINGSPAN)
POP RIVETS
(QUANTITY REQUIRED
SHALL BE DETERMINED
BY INSTALLER)
200 / 300 SERIES PANELS
BEAM PENETRATION
ISOMETRIC
M
I
N
.
3
"
T
R
I
M
L
A
P
M
I
N
.
3
"
T
R
I
M
L
A
P
(2) BEADS
BUTYL SEALANT
200 / 300 SERIES PANELS
TRIM END LAP
M
I
N
.
3
"
T
R
I
M
L
A
P
M
I
N
.
3
"
T
R
I
M
L
A
P
(2) BEADS
BUTYL SEALANT
FIELD NOTCH HEM(S)
AS REQUIRED
(NOT BY KINGSPAN)
200 / 300 SERIES PANELS
TRIM LAP WITH HEM
(2) BEADS
BUTYL SEALANT
N
O
M
.
1
4
"
G
A
P
8" LONG LAP STRIP
200 / 300 SERIES PANELS
TRIM END LAP WITH
LAP STRIP
TRIM INSTALLATION SEQUENCE:
1 DRIP FLASHING HEAD TRIM WITH TABS DOWN
2 SILL TRIM WITH TABS UP
3 JAMB TRIM
4 CAP TRIM AT HEAD
5 EXTERIOR SEALANTS AS REQUIRED
C
A
P
T
R
I
M
A
T
H
E
A
D
D
R
I
P
F
L
A
S
H
I
N
G
A
T
H
E
A
D
CA
P T
RIM
A
T JA
MB
D
R
I
P
F
L
A
S
H
I
N
G
A
T
H
E
A
D
FIELD CUT/NOTCH
CAP TRIM AT
CORNERS TO
ALLOW FOR LAP
(NOT BY KINGSPAN)
FIELD CUT/NOTCH
CAP TRIM AT
CORNERS TO
ALLOW FOR LAP
(NOT BY KINGSPAN)
S
I
L
L
T
R
I
M
OVERLAP TRIMS,
POP RIVET AS
NECESSARY (NOT BY
KINGSPAN)
OVERLAP TRIMS,
POP RIVET AND SEAL
AS NECESSARY (NOT
BY KINGSPAN)
JAMB TRIM
3
DRIP FLASHING WITH
TABS BENT DOWN
1
SILL TRIM WITH TAB
BENT UP
2
CAP TRIM AT HEAD4
SEALANT END DAM
ACROSS DRIP
FLASHING (TYPICAL
BOTH ENDS)
EXPOSED SEALANT
(TYPICAL BOTH
ENDS, NOT BY
KINGSPAN)
VERTICAL SEALANT MARRIAGE BEAD W/
END DAM SEALANT (TYPICAL BOTH ENDS)
5
ISOMETRIC VIEW
SEE (KIP 701) EXPLODED VIEW FOR CLARITY
EXPOSED SEALANT ACROSS SILL TRIM
( NOT BY KINGSPAN)
5
200 / 300 SERIES PANELS
TRIM LAP AT FRAMED
OPENING - ISOMETRIC
EX
TE
RIO
R C
AP
TR
IM
A
T JA
MB
MIN. 3" TAB FOLD OVER
INTERIOR JAMB TRIM,
APPLY SEALANT IN
BETWEEN (TYPICAL
BOTH ENDS)
S
I
L
L
T
R
I
M
MIN. 3" TAB FOLD OVER
INTERIOR JAMB TRIM, APPLY
SEALANT IN BETWEEN
(TYPICAL BOTH ENDS)
1
TRIM INSTALLATION SEQUENCE:
1 INTERIOR JAMB TRIM (NOTCH)
2 DRIP FLASHING HEAD TRIM WITH TABS BENT DOWNS
3 SILL TRIMS WITH TABS BENT UP
4 EXTERIOR JAMB TRIM
5 EXTERIOR CAP TRIM AT HEAD
EXPLODED VIEW
IN
TE
RIO
R C
AP
TR
IM
A
T JA
MB
2
3
4
4
IN
TE
RIO
R C
AP
TR
IM
A
T JA
MB
EX
TE
RIO
R C
AP
TR
IM
A
T JA
MB
1
D
R
I
P
F
L
A
S
H
I
N
G
A
T
H
E
A
D
C
A
P
T
R
I
M
A
T
H
E
A
D
5
200 / 300 SERIES PANELS
TRIM LAP AT FRAMED
OPENING - EXPLODED
VIEW