![Page 1: 3BUSXXXXXXR0001 Page 1 ABB Electricity Metering ABB Automation Inc. Electric Meter Division. Raleigh, NC U.S.A](https://reader034.vdocument.in/reader034/viewer/2022050720/55329ab055034643548b4612/html5/thumbnails/1.jpg)
3BUSXXXXXXR0001 Page 1
ABB Electricity Metering
ABB Automation Inc.
Electric Meter Division.
Raleigh, NC U.S.A.
![Page 2: 3BUSXXXXXXR0001 Page 1 ABB Electricity Metering ABB Automation Inc. Electric Meter Division. Raleigh, NC U.S.A](https://reader034.vdocument.in/reader034/viewer/2022050720/55329ab055034643548b4612/html5/thumbnails/2.jpg)
3BUSXXXXXXR0001 Page 2
ABB Electricity Metering
ABB en los Estados Unidos
Jefferson City
Santa ClaraBloomington
Muncie
St. Louis
Alamo
AthensFlorence
Sanford
Coral Springs
PinetopsRaleigh
GreensboroBland
HamptonSouth Boston
Monmouth Junction
Westborough
AllentownPittsburgh
Greensburg
![Page 3: 3BUSXXXXXXR0001 Page 1 ABB Electricity Metering ABB Automation Inc. Electric Meter Division. Raleigh, NC U.S.A](https://reader034.vdocument.in/reader034/viewer/2022050720/55329ab055034643548b4612/html5/thumbnails/3.jpg)
3BUSXXXXXXR0001 Page 3
ABB Electricity Metering
Temas:
Medidor Alpha A1 Medidor AlphaPlus Software IQ Inspector/AlphaPlus
![Page 4: 3BUSXXXXXXR0001 Page 1 ABB Electricity Metering ABB Automation Inc. Electric Meter Division. Raleigh, NC U.S.A](https://reader034.vdocument.in/reader034/viewer/2022050720/55329ab055034643548b4612/html5/thumbnails/4.jpg)
3BUSXXXXXXR0001 Page 4
ABB Electricity Metering
ABB en los Estados Unidos
1996• $5.4 en ventas• 38,700 empleados
1989
1988
![Page 5: 3BUSXXXXXXR0001 Page 1 ABB Electricity Metering ABB Automation Inc. Electric Meter Division. Raleigh, NC U.S.A](https://reader034.vdocument.in/reader034/viewer/2022050720/55329ab055034643548b4612/html5/thumbnails/5.jpg)
3BUSXXXXXXR0001 Page 5
ABB Electricity Metering
AGENDA
Tipos de Medición Historia de la Tecnología de Medición Medición Digital - Alpha
Tecnología Beneficios a la Industria
![Page 6: 3BUSXXXXXXR0001 Page 1 ABB Electricity Metering ABB Automation Inc. Electric Meter Division. Raleigh, NC U.S.A](https://reader034.vdocument.in/reader034/viewer/2022050720/55329ab055034643548b4612/html5/thumbnails/6.jpg)
3BUSXXXXXXR0001 Page 6
ABB Electricity Metering
Consumo de Electricidad
Punto de Vista de la Empresa Generadora Sistema Ideal - una carga constante Sistema Actual - Una carga variable dependiendo de la
hora del día
![Page 7: 3BUSXXXXXXR0001 Page 1 ABB Electricity Metering ABB Automation Inc. Electric Meter Division. Raleigh, NC U.S.A](https://reader034.vdocument.in/reader034/viewer/2022050720/55329ab055034643548b4612/html5/thumbnails/7.jpg)
3BUSXXXXXXR0001 Page 7
ABB Electricity Metering
Sistema Generador
0
10
20
30
40
50
60
70
80
0:00
4:00
8:00
12:0
0
16:0
0
20:0
0
1/24
/00
0:00
Comb. Turb.
Cycling
Base Oil
Base Coal
Hydro
Nuclear
Dia de Invierno Tipico
GW
Hora del Dia
$ .02/kWh
$ .25/kWh
![Page 8: 3BUSXXXXXXR0001 Page 1 ABB Electricity Metering ABB Automation Inc. Electric Meter Division. Raleigh, NC U.S.A](https://reader034.vdocument.in/reader034/viewer/2022050720/55329ab055034643548b4612/html5/thumbnails/8.jpg)
3BUSXXXXXXR0001 Page 8
ABB Electricity Metering
Tipos de Medición
Energía Activa (kWh) Demanda Máxima (kW) Tiempo de Uso/Multitarifa Energía Reactiva (en kVARh) o kVA Perfil de Carga (Memoria Masiva)
![Page 9: 3BUSXXXXXXR0001 Page 1 ABB Electricity Metering ABB Automation Inc. Electric Meter Division. Raleigh, NC U.S.A](https://reader034.vdocument.in/reader034/viewer/2022050720/55329ab055034643548b4612/html5/thumbnails/9.jpg)
3BUSXXXXXXR0001 Page 9
ABB Electricity Metering
Tipos de Medición
Energía Activa (kWh) - Área debajo de la curva de carga
Facturación - kWh x (costo/kWh)
Hora del Dia0 12 24
kW
![Page 10: 3BUSXXXXXXR0001 Page 1 ABB Electricity Metering ABB Automation Inc. Electric Meter Division. Raleigh, NC U.S.A](https://reader034.vdocument.in/reader034/viewer/2022050720/55329ab055034643548b4612/html5/thumbnails/10.jpg)
3BUSXXXXXXR0001 Page 10
ABB Electricity Metering
Tipos de Medición
Energía Activa (kWh) - Área debajo de la curva de carga
Demanda Máxima - Potencia promedio sobre un periodo de tiempo (siendo lo típico 15 minutos)
![Page 11: 3BUSXXXXXXR0001 Page 1 ABB Electricity Metering ABB Automation Inc. Electric Meter Division. Raleigh, NC U.S.A](https://reader034.vdocument.in/reader034/viewer/2022050720/55329ab055034643548b4612/html5/thumbnails/11.jpg)
3BUSXXXXXXR0001 Page 11
ABB Electricity Metering
Demanda Maxima
0 12 24
kW
Facturación - kWh x (costo/kWh) x (Factor por la Demanda Máxima)
![Page 12: 3BUSXXXXXXR0001 Page 1 ABB Electricity Metering ABB Automation Inc. Electric Meter Division. Raleigh, NC U.S.A](https://reader034.vdocument.in/reader034/viewer/2022050720/55329ab055034643548b4612/html5/thumbnails/12.jpg)
3BUSXXXXXXR0001 Page 12
ABB Electricity Metering
Tipos de Medición
Energía Activa (kWh) - Área debajo de la curva de carga
Demanda Máxima - Potencia promedia sobre un periodo de tiempo (siendo lo típico 15 minutos)
Tiempo de Uso/Multitarifa - Se cobra al cliente según la hora de consumo de energía
![Page 13: 3BUSXXXXXXR0001 Page 1 ABB Electricity Metering ABB Automation Inc. Electric Meter Division. Raleigh, NC U.S.A](https://reader034.vdocument.in/reader034/viewer/2022050720/55329ab055034643548b4612/html5/thumbnails/13.jpg)
3BUSXXXXXXR0001 Page 13
ABB Electricity Metering
Tiempo de Uso/Multitarifa
Facturación = kWh(B) x (costo/kWh hora punta) x (Factor por la Demanda Máxima)
+ kWh(A) x (costo/kWh hora fuera punta)
0 12 24
kW
BA A
![Page 14: 3BUSXXXXXXR0001 Page 1 ABB Electricity Metering ABB Automation Inc. Electric Meter Division. Raleigh, NC U.S.A](https://reader034.vdocument.in/reader034/viewer/2022050720/55329ab055034643548b4612/html5/thumbnails/14.jpg)
3BUSXXXXXXR0001 Page 14
ABB Electricity Metering
Tipos de Medición
Energía Activa (kWh) - Área debajo de la curva de carga
Demanda Máxima - Potencia promedia sobre un periodo de tiempo (siendo lo típico 15 minutos )
Tiempo de Uso/Multitarifa - Se cobra al cliente según la hora de consumo de energía
Energía Reactiva (en kVAR) o kVA - Para calcular el Factor de potencia
![Page 15: 3BUSXXXXXXR0001 Page 1 ABB Electricity Metering ABB Automation Inc. Electric Meter Division. Raleigh, NC U.S.A](https://reader034.vdocument.in/reader034/viewer/2022050720/55329ab055034643548b4612/html5/thumbnails/15.jpg)
3BUSXXXXXXR0001 Page 15
ABB Electricity Metering
Energía Reactiva (en kVAR) o kVA
0 12 24
kW
Facturación - kWh(B) x (costo/kWh en hora punta) x (Factor por la Demanda Máxima)
+ kWh(A) x (costo/kWh en hora fuera punta)
+ Multa por factor de potencia inferior a un limite
BA AkVAR
kVA
kW
kVAR
F.P. = Cos O
![Page 16: 3BUSXXXXXXR0001 Page 1 ABB Electricity Metering ABB Automation Inc. Electric Meter Division. Raleigh, NC U.S.A](https://reader034.vdocument.in/reader034/viewer/2022050720/55329ab055034643548b4612/html5/thumbnails/16.jpg)
3BUSXXXXXXR0001 Page 16
ABB Electricity Metering
Tipos de Medición
Energía Activa (kWh) - Área debajo de la curva de carga Demanda Máxima - Potencia promedia sobre un periodo de tiempo (15
minutos siendo lo típico 15 minutos ) Tiempo de Uso/Multitarifa - Se cobra al cliente según la hora de
consumo de energía Energía Reactiva (en kVAR) o kVA - Para calcular el Factor de potencia Perfil de Carga (Memoria Masiva) - Para hacer estudios de carga,
verificar el consumo, etc.
![Page 17: 3BUSXXXXXXR0001 Page 1 ABB Electricity Metering ABB Automation Inc. Electric Meter Division. Raleigh, NC U.S.A](https://reader034.vdocument.in/reader034/viewer/2022050720/55329ab055034643548b4612/html5/thumbnails/17.jpg)
3BUSXXXXXXR0001 Page 17
ABB Electricity Metering
Perfil de Carga
Facturación - kWh(B) x (costo/kWh hora punta) x (Factor por la Demanda Máxima)
+ kWh(A) x (costo/kWh hora fuera punta)
0 12 24
kW
BA A
![Page 18: 3BUSXXXXXXR0001 Page 1 ABB Electricity Metering ABB Automation Inc. Electric Meter Division. Raleigh, NC U.S.A](https://reader034.vdocument.in/reader034/viewer/2022050720/55329ab055034643548b4612/html5/thumbnails/18.jpg)
3BUSXXXXXXR0001 Page 18
ABB Electricity Metering
Perfil de Carga
![Page 19: 3BUSXXXXXXR0001 Page 1 ABB Electricity Metering ABB Automation Inc. Electric Meter Division. Raleigh, NC U.S.A](https://reader034.vdocument.in/reader034/viewer/2022050720/55329ab055034643548b4612/html5/thumbnails/19.jpg)
3BUSXXXXXXR0001 Page 19
ABB Electricity Metering
Historia de la Tecnología
El Medidor Mecánico Disco de inducción con registrador tipo reloj o ciclometrico. Medición de demanda máxima se lograba empleando un registrador
con motores y engranajes.
![Page 20: 3BUSXXXXXXR0001 Page 1 ABB Electricity Metering ABB Automation Inc. Electric Meter Division. Raleigh, NC U.S.A](https://reader034.vdocument.in/reader034/viewer/2022050720/55329ab055034643548b4612/html5/thumbnails/20.jpg)
3BUSXXXXXXR0001 Page 20
ABB Electricity Metering
Historia de la Tecnología
El Medidor MecánicoVentajas:
Vida útil bastante larga Costo bajo del propio medidor
Desventajas: Precisión no superior al Clase 2.0 según IEC Requieren mantenimiento periódicamente Pierden precisión con el tiempo por desgasto de las piezas movibles Susceptible al fraude Limitado en su funcionalidad e inflexible
![Page 21: 3BUSXXXXXXR0001 Page 1 ABB Electricity Metering ABB Automation Inc. Electric Meter Division. Raleigh, NC U.S.A](https://reader034.vdocument.in/reader034/viewer/2022050720/55329ab055034643548b4612/html5/thumbnails/21.jpg)
3BUSXXXXXXR0001 Page 21
ABB Electricity Metering
Historia de la Tecnología
El Medidor Híbrido Disco de inducción con registrador de estado solido de
pantalla LCD (Cristal Liquido)
+ 0000.0
![Page 22: 3BUSXXXXXXR0001 Page 1 ABB Electricity Metering ABB Automation Inc. Electric Meter Division. Raleigh, NC U.S.A](https://reader034.vdocument.in/reader034/viewer/2022050720/55329ab055034643548b4612/html5/thumbnails/22.jpg)
3BUSXXXXXXR0001 Page 22
ABB Electricity Metering
Historia de la Tecnologia
El Medidor HibridoVentajas
Vida útil bastante larga Costo bajo del propio medidor Permitían medición en multitarifas Perfil de Carga Menos fallas del registrador que el caso con medidores de demanda mecánica.
![Page 23: 3BUSXXXXXXR0001 Page 1 ABB Electricity Metering ABB Automation Inc. Electric Meter Division. Raleigh, NC U.S.A](https://reader034.vdocument.in/reader034/viewer/2022050720/55329ab055034643548b4612/html5/thumbnails/23.jpg)
3BUSXXXXXXR0001 Page 23
ABB Electricity Metering
Historia de la Tecnologia
El Medidor HibridoDesventajas:
Precisión no superior al Clase 2.0 según IEC Requieren mantenimiento periódicamente Pierden precisión con el tiempo por desgasto de
las piezas movibles Susceptible al fraude Limitado en su funcionalidad e inflexible
![Page 24: 3BUSXXXXXXR0001 Page 1 ABB Electricity Metering ABB Automation Inc. Electric Meter Division. Raleigh, NC U.S.A](https://reader034.vdocument.in/reader034/viewer/2022050720/55329ab055034643548b4612/html5/thumbnails/24.jpg)
3BUSXXXXXXR0001 Page 24
ABB Electricity Metering
Historia de la Tecnología
El Medidor Estado Solido Senales de entrada pasan por transformadores de corriente y potenciaVentajas: Clase de precision 0.5 o 0.2 segun IEC Integracion de medicion reactiva Establidad Deteccion de Fraude Comunicacion Remota (Modem)
![Page 25: 3BUSXXXXXXR0001 Page 1 ABB Electricity Metering ABB Automation Inc. Electric Meter Division. Raleigh, NC U.S.A](https://reader034.vdocument.in/reader034/viewer/2022050720/55329ab055034643548b4612/html5/thumbnails/25.jpg)
3BUSXXXXXXR0001 Page 25
ABB Electricity Metering
Historia de la Tecnología
El Medidor Estado Solido
Desventajas: Costo - solamente permitia su aplicacion en las
instalaciones mas importantes Cierta Inflexibilidad
![Page 26: 3BUSXXXXXXR0001 Page 1 ABB Electricity Metering ABB Automation Inc. Electric Meter Division. Raleigh, NC U.S.A](https://reader034.vdocument.in/reader034/viewer/2022050720/55329ab055034643548b4612/html5/thumbnails/26.jpg)
3BUSXXXXXXR0001 Page 26
ABB Electricity Metering
El Medidor Digital Alpha
Entradas de corriente y voltaje pasan por un convertidor analógico/digital
De ahí se pasan para el Procesador Digital de Señales
A/D DSPV
C
DisplayCommetc.
![Page 27: 3BUSXXXXXXR0001 Page 1 ABB Electricity Metering ABB Automation Inc. Electric Meter Division. Raleigh, NC U.S.A](https://reader034.vdocument.in/reader034/viewer/2022050720/55329ab055034643548b4612/html5/thumbnails/27.jpg)
3BUSXXXXXXR0001 Page 27
ABB Electricity Metering
Alpha - Ventajas
Exactitud de Clase 0.2 según CEI y mantiene esta exactitud con variaciones de: Corriente de Carga Voltaje Factor de Potencia Temperatura Frecuencia Combinaciones de Estas Características
La precisión se mantiene por la vida del medidor sin necesidad de calibración.
![Page 28: 3BUSXXXXXXR0001 Page 1 ABB Electricity Metering ABB Automation Inc. Electric Meter Division. Raleigh, NC U.S.A](https://reader034.vdocument.in/reader034/viewer/2022050720/55329ab055034643548b4612/html5/thumbnails/28.jpg)
3BUSXXXXXXR0001 Page 28
ABB Electricity Metering
Alpha - Ventajas
Alta Flexibilidad Vía Programación Sencilla Demanda. Multitarifa Medición de Energía Activa y Reactiva
Mejor Seguridad No hay manera “fácil” de cambiar los valores registrados del
medidor. Es bien difícil hacer fraude y la mayoría de los intentos se pueden
detectar.
![Page 29: 3BUSXXXXXXR0001 Page 1 ABB Electricity Metering ABB Automation Inc. Electric Meter Division. Raleigh, NC U.S.A](https://reader034.vdocument.in/reader034/viewer/2022050720/55329ab055034643548b4612/html5/thumbnails/29.jpg)
3BUSXXXXXXR0001 Page 29
ABB Electricity Metering
Alpha - Experiencia
Experiencia Extensiva Medidores electrónicos en servicio desde 1986 Productos de medición usando microprocesadores desde 1978 Un sistema de software bien avanzado. Mas de 3,000,000 medidores Alpha en servicio (mas de 120,000
medidores en Mexico). Menos de 0.2% fallo de equipo en campo.
![Page 30: 3BUSXXXXXXR0001 Page 1 ABB Electricity Metering ABB Automation Inc. Electric Meter Division. Raleigh, NC U.S.A](https://reader034.vdocument.in/reader034/viewer/2022050720/55329ab055034643548b4612/html5/thumbnails/30.jpg)
3BUSXXXXXXR0001 Page 30
ABB Electricity Metering
Configuraciones
Base ATableroIECANSI Socket
![Page 31: 3BUSXXXXXXR0001 Page 1 ABB Electricity Metering ABB Automation Inc. Electric Meter Division. Raleigh, NC U.S.A](https://reader034.vdocument.in/reader034/viewer/2022050720/55329ab055034643548b4612/html5/thumbnails/31.jpg)
3BUSXXXXXXR0001 Page 31
ABB Electricity Metering
Alpha - Tipos
Tipos del Medidor Alpha A1D - kWh y kW A1T - kWh y kW en hasta 4 tarifas A1R - kWh, kVARh y kW (o kVAR) en hasta 4 tarifas A1K - (Igual que el A1R pero kVAh en vez de kVARh)
![Page 32: 3BUSXXXXXXR0001 Page 1 ABB Electricity Metering ABB Automation Inc. Electric Meter Division. Raleigh, NC U.S.A](https://reader034.vdocument.in/reader034/viewer/2022050720/55329ab055034643548b4612/html5/thumbnails/32.jpg)
3BUSXXXXXXR0001 Page 32
ABB Electricity Metering
Alpha -Tarjetas Avanzadas
Tarjetas de Funciones Avanzadas: - L : Un canal de perfil de carga para kW entregados solamente.
Tiene 32k de memoria que es suficiente para 147 días de grabación con un intervalo de 15 minutos. Se usa con el Alpha A1T, A1R o A1K.
-A : Permite medición en los cuatro cuadrantes (Bidireccionalidad). Se usa con el Alpha A1R o A1K.
-AL : Igual que el -A pero además tiene 4 canales de perfil de carga con 128 Kbytes de memoria que es suficiente para 140 días de grabación cuando se esta usando los 4 canales con un intervalo de 15 minutos.
![Page 33: 3BUSXXXXXXR0001 Page 1 ABB Electricity Metering ABB Automation Inc. Electric Meter Division. Raleigh, NC U.S.A](https://reader034.vdocument.in/reader034/viewer/2022050720/55329ab055034643548b4612/html5/thumbnails/33.jpg)
3BUSXXXXXXR0001 Page 33
ABB Electricity Metering
Alpha - Salidas de Relevadores
Tarjetas de Relevadores: 1 Relevador: Pulsos KYZ de kWh entregado. 2 Relevadores: Primera salida da pulsos KYZ de kWh entregado.
Segunda salida se puede programar para pulsos KYZ de KVARh entregados, indicacion del final del intervalo de demanda o para control de carga.
6 Relevadores: Para salidas de KYZ kWh entregado, kWh recibido, kVARh entregado, kVARh recibido, control de carga y indicacion de final de intervalo.
![Page 34: 3BUSXXXXXXR0001 Page 1 ABB Electricity Metering ABB Automation Inc. Electric Meter Division. Raleigh, NC U.S.A](https://reader034.vdocument.in/reader034/viewer/2022050720/55329ab055034643548b4612/html5/thumbnails/34.jpg)
3BUSXXXXXXR0001 Page 34
ABB Electricity Metering
Tarjetas de Comunicacion
Tarjeta de Modem interno para comunicacion a 2400 baud. Tarjeta para modem externo con comunicacion de 2400 a
19,200 baud.
![Page 35: 3BUSXXXXXXR0001 Page 1 ABB Electricity Metering ABB Automation Inc. Electric Meter Division. Raleigh, NC U.S.A](https://reader034.vdocument.in/reader034/viewer/2022050720/55329ab055034643548b4612/html5/thumbnails/35.jpg)
3BUSXXXXXXR0001 Page 35
ABB Electricity Metering
Alpha Con Tarjeta “AL”
![Page 36: 3BUSXXXXXXR0001 Page 1 ABB Electricity Metering ABB Automation Inc. Electric Meter Division. Raleigh, NC U.S.A](https://reader034.vdocument.in/reader034/viewer/2022050720/55329ab055034643548b4612/html5/thumbnails/36.jpg)
3BUSXXXXXXR0001 Page 36
ABB Electricity Metering
Tarjeta de Modem Interno
![Page 37: 3BUSXXXXXXR0001 Page 1 ABB Electricity Metering ABB Automation Inc. Electric Meter Division. Raleigh, NC U.S.A](https://reader034.vdocument.in/reader034/viewer/2022050720/55329ab055034643548b4612/html5/thumbnails/37.jpg)
3BUSXXXXXXR0001 Page 37
ABB Electricity Metering
Tarjeta de Modem Interno
![Page 38: 3BUSXXXXXXR0001 Page 1 ABB Electricity Metering ABB Automation Inc. Electric Meter Division. Raleigh, NC U.S.A](https://reader034.vdocument.in/reader034/viewer/2022050720/55329ab055034643548b4612/html5/thumbnails/38.jpg)
3BUSXXXXXXR0001 Page 38
ABB Electricity Metering
Tarjeta de Modem Externo
![Page 39: 3BUSXXXXXXR0001 Page 1 ABB Electricity Metering ABB Automation Inc. Electric Meter Division. Raleigh, NC U.S.A](https://reader034.vdocument.in/reader034/viewer/2022050720/55329ab055034643548b4612/html5/thumbnails/39.jpg)
3BUSXXXXXXR0001 Page 41
ABB Electricity Metering
Desarrollo del Medidor Alpha
1990Juntas con clientes para definir medidor.
1992•Auto-rango•Multiple Servicios• Precision 0.2%
1991Diseno del medidor Alpha.
1993•Alpha Keys•Medicion Reactiva
1995
200K
400K
600K
Un
idad
es E
n
Ser
vici
o
1996•ModemExterno e Interno
1994•Medicion tipo instrumento•Power Quality•Verificacion de servicio
•Tarjetas“A” y “AL”
![Page 40: 3BUSXXXXXXR0001 Page 1 ABB Electricity Metering ABB Automation Inc. Electric Meter Division. Raleigh, NC U.S.A](https://reader034.vdocument.in/reader034/viewer/2022050720/55329ab055034643548b4612/html5/thumbnails/40.jpg)
3BUSXXXXXXR0001 Page 42
ABB Electricity Metering
Alpha - Funcciones y Beneficios
Mantiene la precisión de 0.2% durante la vida del medidor.
Beneficio - Se elimina el mantenimiento inicial y periódico que se requiere con medidores tradicionales.
Operación correcta en cualquier tensión de 96 a 528 voltios.
Beneficio - Reducción de inventario y reduce errores de instalación.
Hora se mantiene con la frecuencia de la línea o un cristal interno - programable.
Capacidad de actualizar el medidor a otras funciones.
Beneficio - El cliente no esta limitado al medidor que compra inicialmente.
![Page 41: 3BUSXXXXXXR0001 Page 1 ABB Electricity Metering ABB Automation Inc. Electric Meter Division. Raleigh, NC U.S.A](https://reader034.vdocument.in/reader034/viewer/2022050720/55329ab055034643548b4612/html5/thumbnails/41.jpg)
3BUSXXXXXXR0001 Page 43
ABB Electricity Metering
Alpha - Funcciones y Beneficios
El mismo medidor sirve para servicio en Delta y Estrella de 3 elementos.
Beneficio - Reducción de inventario. Los datos de energía y demanda del Alpha A1D se
mantienen en memoria permanente tipo EEPROM.
Beneficio - No se pierde datos en caso de un apagón. Batería litio con una vida útil de 20 años y continua de 5
años para respaldar el reloj interno y datos de memoria masiva. Opera en conjunto con un capacitor que alimenta la memoria por 6 horas antes de tener que usar la batería.
Benefico - La batería debe de durar la vida del medidor.
![Page 42: 3BUSXXXXXXR0001 Page 1 ABB Electricity Metering ABB Automation Inc. Electric Meter Division. Raleigh, NC U.S.A](https://reader034.vdocument.in/reader034/viewer/2022050720/55329ab055034643548b4612/html5/thumbnails/42.jpg)
3BUSXXXXXXR0001 Page 44
ABB Electricity Metering
Alpha - Actualizacion
A1D A1T A1T-L A1R A1R-L A1R-A A1R-AL
![Page 43: 3BUSXXXXXXR0001 Page 1 ABB Electricity Metering ABB Automation Inc. Electric Meter Division. Raleigh, NC U.S.A](https://reader034.vdocument.in/reader034/viewer/2022050720/55329ab055034643548b4612/html5/thumbnails/43.jpg)
3BUSXXXXXXR0001 Page 45
ABB Electricity Metering
Alpha - Seguridad
Numero de reposiciones de la demanda máxima Fecha, hora y duración del ultimo apagón Duración total de todos los apagones Comunicaciones con el Medidor
![Page 44: 3BUSXXXXXXR0001 Page 1 ABB Electricity Metering ABB Automation Inc. Electric Meter Division. Raleigh, NC U.S.A](https://reader034.vdocument.in/reader034/viewer/2022050720/55329ab055034643548b4612/html5/thumbnails/44.jpg)
3BUSXXXXXXR0001 Page 46
ABB Electricity Metering
ALPHAPLUS - Software de Comunicacion
Funciones: Programación Lecturas Reportes Opera con los medidores Alpha y AlphaPlus Compatible con Computadoras Portátiles como el DAP
PC9800
![Page 45: 3BUSXXXXXXR0001 Page 1 ABB Electricity Metering ABB Automation Inc. Electric Meter Division. Raleigh, NC U.S.A](https://reader034.vdocument.in/reader034/viewer/2022050720/55329ab055034643548b4612/html5/thumbnails/45.jpg)
3BUSXXXXXXR0001 Page 47
ABB Electricity Metering
Resumen
Alpha ofrece: Precisión 0.2 a un precio razonable Reducción de inventario por multitension y reducción de
formas Reducción o eliminación de mantenimiento Detección de Fraude Capacidad de Actualización