Sterile Processing for the Infection Preventionist: What you need to know?November 19, 2015
© 3M 2015. All Rights Reserved
Welcome!Topic: Sterile Processing for the Infection Preventionist: What
you need to know?
• Facilitators: Christophe de Campeau, 3M Sandra Velte, 3M
• Speakers: Jacqueline Daley HBSc, MLT, CIC, CSPDS
• For more information: www.3m.Com/3MSterileU
© 3M 2015. All Rights Reserved 3
House Keeping
From the GoToWebinar page:• Click on the orange box with a
white arrow to expand your control panel (upper right-hand corner of your screen).
• Type a question in the question box and click send.
18/11/2015
2
© 3M 2015. All Rights Reserved 4
House Keeping
Continuing EducationEach 1 hour web meeting is approved by IAHCSMM, CBSPD and is 3M Health Care Provider approved by the California Board of Registered Nurses CEP 5770 for one contact hour.
Post webinar email• Link to Course Evaluation• CS Tech CE Certificate Included• Forward eMail to others in attendance
© 3M 2015. All Rights Reserved 5
•Jacqueline Daley HBSc, MLT, CIC, CSPDSManager Infection Prevention, Clinical Epidemiology and Vascular Access ServiceSharp Metropolitan Medical Center
• 3M Educational Consultant• Speaker’s Bureau Sage Products
© 3M 2015. All Rights Reserved 6
Learning Objectives
• Identify the impact of standards, guidelines, recommended practices and regulatory agencies on the Central Sterile Department/Sterile Processing Department as it relates to Infection Prevention
• Review the role of the Joint Commission in the Sterile Processing Department (SPD) as it relates to Infection Prevention
• Discuss best practices for monitoring the sterilization process and why biological indicators are considered the most effective method for monitoring the sterilization process
• Understand the importance of procedures for recall of potentially contaminated equipment and supplies
• List three areas of concern in the Sterile Processing Department (SPD) that impacts infection prevention
18/11/2015
3
© 3M 2015. All Rights Reserved 7
Role of Sterile Processing Department (SPD)
“The importance of this [SPD] role in the prevention of nosocomial [HAIs] is clear: reusable medical devices improperly handled, disinfected, or sterilized provide a source of contamination and increase the risk of transmission of infection to both patients and the staff involved in reprocessing procedures.”
Pugliese, Gina and Hunstiger. Central Services, Linens and Laundry. In Hospital Infections. Edited by John V. Bennett and Philip S. Brachman. 3rd ed.
© 3M 2015. All Rights Reserved 8
Standard, Guidelines and Professional Bodies
• Association for Professionals in Infection Control and Prevention (APIC)• Position Statements
• Association of periOperative Registered Nurses (AORN)• Recommended Practices
• Society for Healthcare Epidemiology of America (SHEA)
• The Joint Commission (TJC)• Infection Prevention and Control Standards
• Association for the Advancement of Medical Instrumentation (AAMI)
• Society of Gastroenterology and Associates, Inc (SGNA)
• American Society for Gastrointestinal Endoscopy (ASGE)
© 3M 2015. All Rights Reserved 9
Government and Regulatory Agencies• Center for Disease Control and Prevention (CDC)
• Guideline for Disinfection and Sterilization in Healthcare Facilities, 2008
• Environmental Protection Agency (EPA)• Office of Pesticides Program-Antimicrobials Division (OPP-AD) is responsible for all regulatory activities
associated with antimicrobial pesticides.
• Regulates items used to sanitize and disinfect environmental surfaces and sterilants such as ethylene oxide
• Food and Drug Administration (FDA)• Medical instruments and device approval through the 510K process
• Approval of products used as sterilants and high-level disinfectants with general claims for reprocessing reusable medical and dental devices
• Center for Medicare Medicaid (CMS)• Conditions of Participation
• Hospital Infection Worksheet – Sec 3.A. Reprocessing Semi-Critical Equipment; Sec 3.B. Reprocessing of Reusable Critical Equipment, Instruments and Devices: Sterilization
• Local and state regulations
18/11/2015
4
© 3M 2015. All Rights Reserved 10
Association for Professionals in Infection Control and Prevention (APIC)
• Impact on Sterile Processing• Endorses standards and guidelines through participation on committees such as AAMI and
Healthcare Infection Control Practices Advisory Committee (HICPAC), Centers for Disease Control & Prevention (CDC).
• Development of Position Statements• **Important information for infection preventionists regarding media attention on an outbreak
involving reusable surgical instruments.• “Infection preventionists can play an important role in collaboration with the perioperative team
and the facility’s sterile processing department (SPD)/surgical reprocessing professionals to ensure the proper cleaning and sterilization of surgical instruments.”
• Develops competencies for infection preventionists to ensure a clear understanding and management of risks in department to include the practices in Central Sterile / Sterile Processing• Allows for assessment of practices in this domain
http://apicweb.beta.deghosting.com/Resource_/TinyMceFileManager/Position_Statements/Dirty_Surgical_Instruments_TalkingPoints.pdf
© 3M 2015. All Rights Reserved
• Supports initiatives that actively promote certification of sterile processing personnel
• Provides a course on “Disinfection and Sterilization: Best Practices in Reprocessing Surgical Instruments”
• Helps healthcare professionals in all settings ensure compliance with regulatory standards for sterile processing and adhere to recommended best practices.
**http://www.apic.org/Resource_/TinyMceFileManager/Position_Statements/Dirty_Surgical_Instruments_TalkingPoints.pdf
Association for Professionals in Infection Control and Prevention (APIC)
© 3M 2015. All Rights Reserved
• Recommended Practices• Cleaning and care of surgical instruments and powered equipment• Selection and use of packaging systems for sterilization
• Evaluating, selecting, and using packaging systems and for packaging the items to be sterilized and used in the perioperative setting
• Sterilization• Provides guidance for sterilizing items in the perioperative setting
Association of periOperative Registered Nurses (AORN)
18/11/2015
5
© 3M 2015. All Rights ReservedThe Joint Commission: 2015 Hospital Accreditation Standards
© 3M 2015. All Rights Reserved 14
Top Standards Compliance Issues for 2014
• Ambulatory Surgery• 41% IC.02.02.01 The organization reduces the risk of infections associated with medical
equipment, devices, and supplies.
• 22% IC.01.03.01 The organization identifies risks for acquiring and transmitting infections.
• Office-Based Surgery Practices• 39% IC.02.02.01 The practice reduces the risk of infections associated with medical
equipment, devices, and supplies.
• 19% IC.01.03.01 The practice identifies risks for acquiring and transmitting infections.
• 17% IC.01.04.01 Based on the identified risks, the practice sets goals to minimize the possibility of transmitting infections independent practitioners and staff.
Joint Commission Perspectives®, April 2015, Volume 35, Issue 4
© 3M 2015. All Rights Reserved
• LD.04.01.01, EP2• The hospital provides care,
treatment, and services in accordance with licensure requirements, laws and regulations
• LD.04.03.07• Patients with comparable needs
receive the same standard of care, treatment, and services throughout the hospital
• LD.04.04.07
• The hospital considers clinical practice guidelines when designing or improving processes.
• IC.02.02.01 - The organization reduces the risk of infections associated with medical equipment, devices and supplies.
• The hospital implements infection prevention and control activities when doing the following:• EP1- Cleaning and performing low-level
disinfection of medical equipment, devices, and supplies.
• EP2 - The hospital implements infection prevention and control activities when doing the following: Performing intermediate and high-level disinfection and sterilization of medical equipment, devices, and supplies.
The Joint Commission: 2015 Hospital Accreditation Standards
The Joint Commission
18/11/2015
6
© 3M 2015. All Rights Reserved
• Evidence-based Guidelines• Standard IC.01.05.01, EP 1 - Lack of having—and/or lack of using—current evidence-
based guidelines for cleaning, disinfection, high-level disinfection, and sterilization practices is a frequently identified issue and includes knowledge of guideline content and accessibility of guidelines (electronic or manual) for staff use.
• Orientation, Training, and Competency• Standard IC.02.02.01 - lack of orientation, training, and competency (initial and ongoing)
of all staff involved in processing or handling semi-critical and critical devices that require high-level disinfection or sterilization.
The Joint Commission Perspectives February 2014
The Joint Commission – Issues with High-Level Disinfection (HLD)
© 3M 2015. All Rights Reserved
• Quality Control and Quality Monitoring• Standard IC.01.05.01, EP 2 - lack of quality control for high-level
disinfection and the lack of quality monitoring for sterilization.
• Supervisory and Infection Prevention and Control Staff• Fourth most frequently identified issue involves the participation and collaboration of
staff in monitoring high-level disinfection and sterilization processes.
• Record Keeping• Fifth most frequently noted issue involves documentation.
The Joint Commission Perspectives February 2014
The Joint Commission – Issues with High-Level Disinfection (HLD)
© 3M 2015. All Rights Reserved
Findings from non-complying organizations include:• Mistaken belief that the risk of passing bloodborne pathogens or bacterial agents to patients is low• Staff lack the knowledge or training required to properly sterilize or high-level disinfect equipment• Staff do not have access to or lack knowledge of evidence-based guidelines• Lack of leadership support• Frequent leadership and staff turnover makes sterilization or high-level disinfection of equipment a
low priority• Lack of a culture of safety that supports the reporting of safety risks• Processes for sterilization or high-level disinfection are not followed (i.e., staff take short-cuts)• Time frames for proper sterilization or high-level disinfection of equipment are not followed• No dedicated staff person to oversee the proper sterilization or high-level disinfection of equipment
http://www.jointcommission.org/assets/1/23/Quick_Safety_Issue_Two_May_2014.pdf
The Joint Commission’s Office of Quality Monitoring
18/11/2015
7
© 3M 2015. All Rights Reserved
• Facility design or space issues prevent proper sterilization or high-level disinfection of equipment (e.g., processing takes place in a small room that is also used for storage)
• Lack of monitoring or documentation of sterilization or high-level disinfection of equipment, which makes it difficult to track the use of equipment on a specific patient, complicating the patient notification process when an outbreak occurs
• Equipment is spread throughout the facility and may be processed or stored in numerous locations, making it difficult to track the equipment for documentation purposes.
http://www.jointcommission.org/assets/1/23/Quick_Safety_Issue_Two_May_2014.pdf
The Joint Commission’s Office of Quality Monitoring (cont’d)
© 3M 2015. All Rights Reserved
• EC.02.05.01 The hospital manages risks associated with its utility systems
• EP 6: In areas designed to control airborne contaminants (such as biological agents, gases, fumes, dust), the ventilation system provides appropriate pressure relationships, air exchange rates and filtration efficiencies
• Move from clean to dirty
• Decontamination – negative pressure
• Prep and Pack – positive pressure
• Sterile storage – positive pressure
Joint Commission Problematic Standards
© 3M 2015. All Rights Reserved
• The Joint Commission will survey for:• Orientation, training and competency of the health care worker
(HCW) who process medical equipment, devices and supplies• Levels of staffing and supervision of the HCW who process medical
equipment, devices and supplies• Standardization of the process regardless of whether it is centralized
or decentralized• Ongoing quality monitoring• Observation against the manufacturers guidelines and the
organization procedures.
The Joint Commission Perspectives. October 2009 Vol 29 (10)
The Joint Commission Survey
18/11/2015
8
© 3M 2015. All Rights Reserved 22
CDC Health Alert Network (HAN)
“The Centers for Disease Control and Prevention (CDC) and U.S. Food and Drug Administration (FDA) are alerting healthcare providers and facilities about the public health need to properly maintain, clean, and disinfect or sterilize reusable medical devices. Recent infection control lapses due to non-compliance with recommended reprocessing procedures highlight a critical gap in patient safety. Healthcare facilities (e.g., hospitals, ambulatory surgical centers, clinics, and doctors’ offices) that utilize reusable medical devices are urged to immediately review current reprocessing practices at their facility to ensure they (1) are complying with all steps as directed by the device manufacturers, and (2) have in place appropriate policies and procedures that are consistent with current standards and guidelines.
http://emergency.cdc.gov/han/han00383.asp September 11, 2015, 12:15 EDT (12:15 PM EDT) CDCHAN-00382
© 3M 2015. All Rights Reserved
Our wake up call from the Joint Commission and CMS
Patient
TJC / CMS
HealthcareFacilities
http://www.komar.org/faq/churchill_polar_bear_tours/other-animals-fun-stuff/2009_11_09_5419-churchill-polar-bears.jpg
© 3M 2015. All Rights Reserved
Under continuous review and maintenance.
ANSI/AAMI ST79:2010 & A1:2010 &A2:2011 & A3:2012 & A4:2013 (Consolidated Text)
18/11/2015
9
© 3M 2015. All Rights Reserved
• CQI programs are used to assess and improve all components of the sterilization process
• Desired outcome of improving patient care by consistently delivering sterile product to the userNo single “right way” to implement CQI
• Team approach
Reprinted from ANSI/AAMI ST79:2010 & A1:2010 &A2:2011 & A3:2012 & A4:2013 Section 11
Continuous Quality Improvement (CQI) – AAMI ST 79 Section 11
© 3M 2015. All Rights Reserved
• Cleaning and Decontamination
• Preparation and Packaging
• Sterilization
• Sterile Storage and Distribution• Record Keeping
• Recall Procedures
What are the key parts of the process?
© 3M 2015. All Rights Reserved
• Instruments requiring extended cycles
• Original packaging changed for sterilization
• Flexible endoscopes not properly processed for patient use
• Late arrival of loaner instruments to allow for reprocessing according to IFU and quarantine implants for BI results
• Wrong BI process challenge device is run during routine testing
• Improperly reprocessed eye sets with improper reprocessing to prevent TASS
• Daily verification of mechanical cleaning equipment not done at least daily
• Manufacturer’s IFU for cleaning not followed
Young, Martha Top 10 Risk in Sterile Processing. AAMI Horizons Spring 2012
Risks in Sterile Processing
18/11/2015
10
© 3M 2015. All Rights Reserved
“The sterilization risk analysis should be part of the overall infection prevention and control risk analysis in accordance with accreditation agency requirements.”
• Risk assessment (FMEA)
• Risk management (ANSI/AAMI ST79, Root cause analysis)
• Risk communication (Recall procedure)
“It should be performed annually and should be reevaluated whenever significant changes occur.”
Reprinted from ANSI/AAMI ST79:2010 & A1:2010 &A2:2011 & A3:2012 & A4:2013 Clause 11.2.2
Risk analysis = risk assessment + risk management + risk communication
Sterilization Risk Analysis
© 3M 2015. All Rights Reserved
• Failure Modes and Effects Analysis (FMEA)
• Proactive risk assessment • Assess the relative impact of
different failures, in order to identify the parts of the process that are most in need of change.
• Root Cause Analysis• Reactive/Retrospective Process
• identify deficiencies or root cause for the error or adverse event
• Cause and effect fishbone diagram
• Answers the “Why” questions
• Based on analysis, identify improvements and implement to avoid recurrence
http://www.ihi.org
Sterilization Risk Analysis
© 3M 2015. All Rights Reserved
CLEANING AND OTHER DECONTAMINATION PROCESSES
Manual or Mechanical? If you can’t clean it, you can’t sterilize it!
18/11/2015
11
© 3M 2015. All Rights Reserved
• Liquid-resistant covering with sleeves
• Heavy-duty latex free or plastic gloves
• Surgical face mask (impervious to fluid and high filtration)
• Safety glasses that wrap around the eye or face shield
• Disposable hair covering• Proper footwear
Reprinted from ANSI/AAMI ST79:2010 & A1:2010 &A2:2011 & A3:2012 & A4:2013 Clause 4.5.1
Personal Protective Equipment (PPE) – Portal of Exit/Entry
© 3M 2015. All Rights Reserved
The purpose of decontamination is to prevent the spread of infection.
© 3M 2015. All Rights Reserved
• “To be rendered safe to handle, some medical devices require only thorough cleaning; others, because of occupational exposure considerations, must be cleaned and subjected to a microbicidal process. Some devices can be prepared for patient reuse following the decontamination process, whereas others must be prepared and subjected to terminal sterilization (e.g., steam sterilization of surgical instruments).” (Clause 7.1)
• “The type of decontamination required for a particular contaminated device depends on the biohazard that the device presents.” (Clause 7.1)
• “The written [instructions for use] IFU of the device manufacturer should always be followed.” (Clause 7.2.2)
• “Surgical instruments and other items composed of more than one part or piece (e.g., metal tracheostomy tubes, procedure needles, dental handpieces, laparoscopic instrumentation, trumpet valves) should be disassembled to expose all surfaces to the cleaning process.” (Clause 7.4.1)
Reprinted from ANSI/AAMI ST79:2010 & A1:2010 &A2:2011 & A3:2012 & A4:2013 Sec. 7.1 & 7.2.2 & 7.4.1
Cleaning and other Decontamination Processes
18/11/2015
12
© 3M 2015. All Rights Reserved
“For all reusable, the first and most important step in decontamination is thorough cleaning and rinsing.” (Clause 7.5.1) Reprinted from ANSI/AAMI ST79:2010 & A1:2010 &A2:2011 & A3:2012 & A4:2013 Clause 7.5.1
http://www.palmpressinc.com/product-tag/baby-in-sink/
© 3M 2015. All Rights Reserved 35
Polling Question
How do you monitor the cleanliness of instruments after the decontamination process?a. Visual inspection onlyb. Visual inspection plus a cleaning monitoring productc. We do not monitor the cleaning process
© 3M 2015. All Rights Reserved
PACKAGING
“The primary functions of a package containing a medical item are to allow the sterilization of the contents, to maintain the sterility of the contents until the package is opened, and to provide for the removal of the contents without contamination.”
Reprinted from ANSI/AAMI ST79:2010 & A1:2010 &A2:2011 & A:2012 & A4:2013 Clause 8.2 Rationale
18/11/2015
13
© 3M 2015. All Rights Reserved
Paper-Plastic Pouches – “The plastic laminate used in paper–plastic pouches is impervious to the sterilant and, therefore, might prevent the sterilant from reaching the surface of anything with which the plastic side is in physical contact. Therefore, paper–plastic pouches should not be used within wrapped sets or containment devices unless the practice has been validated by the packaging manufacturer and verified by product testing in the health care facility.”
• ANSI/AAMI ST77:2013 Rigid Container Systems (Manufacturer Standard)
• Ergonomic issue• “The combined weight of the containment
device, the instruments, and any accessories or wrappers shall not exceed 25 pounds…”
• When containment devices, including their contents and any accessories or wrappers, are too heavy, sterilization and/or drying could be compromised in commonly available hospital sterilization cycles.
Reprinted from ANSI/AAMI ST79:2010 & A1:2010 &A2:2011 & A3:2012 &A4:2013 Clause 8.3.4 & 8.4.2 Rationale
Packaging Concerns
© 3M 2015. All Rights Reserved
STEAM STERILIZATION
The first step in being able to monitor the steam sterilization process is to know the type of steam sterilizer that is used.
© 3M 2015. All Rights Reserved 39
Steam Sterilization • Type of Steam Sterilization
Process• Gravity Displacement• Dynamic-Air-Removal
Prevacuum• Steam-flush pressure-pulse
(SFPP)
• Critical Parameters• Time • Temperature• Saturated Steam
18/11/2015
14
© 3M 2015. All Rights Reserved
•Process designed for the steam sterilization of patient care items for immediate use
•High temperature (132-135°C / 270-275°F)• Gravity or dynamic-air-removal
• No dry time
• No storage
Immediate Use Steam Sterilization (IUSS) (Formerly Flash Sterilization)
© 3M 2015. All Rights Reserved
Minimum cycle times at 121°C/250°F for gravity displacement steam sterilization cycles for sterilizers >2 cubic feet
Load Contents Time (Min)
Wrapped instruments 30
Textile packs 30
Wrapped utensils 30
Gravity Displacement - Cycle Time Examples
ANSI/AAMI ST79:2010 & A1:2010 &A2:2011 & A3:2012 & A4:2013 8.1 Table 4
© 3M 2015. All Rights Reserved
Minimum cycle times for dynamic-air-removal steam sterilization cycles >2 cubic feet
Load Contents Temp Time (Min)
Wrapped instruments132°C/270°F135°C/275°F
43
Textile packs132°C/270°F135°C/275°F
43
Wrapped utensils132°C/270°F135°C/275°F
43
Unwrapped, non porous items (e.g. instruments)
132°C/270°F135°C/275°F
33
Unwrapped non‐porous/porous in mixed load
132°C/270°F135°C/275°F
43
Dynamic Air Removal - Cycle Time Examples
ANSI/AAMI ST79:2010 & A1:2010 &A2:2011 & A3:2012 & A4:2013 8.1 Table 5
18/11/2015
15
© 3M 2015. All Rights Reserved
Load Contents Temp Time (Min)
Unwrapped instruments on tray or glassware
132°C/270°F135°C/275°F ≥3
Wrapped trays of instruments,instruments in peel pouches
132°C/270°F135°C/275°F ≥5
Packs, wrapped 121°C/250°F ≥30
Table Top Gravity Steam Sterilizers
ANSI/AAMI ST79:2010 & A1:2010 &A2:2011 & A3:2012 & A4:2013 8.1 Table 4
© 3M 2015. All Rights Reserved
Minimum cycle times for immediate-use steam sterilization cycles >2 cubic feet – Gravity displacement
Load Contents TempTime (Min)
Unwrapped non‐porous items (e.g., instruments)
132°C/270°F135°C/275°F
33
Unwrapped non‐porous and porous items in mixed load
132°C/270°F135°C/275°F
1010
Gravity Displacement - Cycle Time Examples
ANSI/AAMI ST79:2010 & A1:2010 &A2:2011 & A3:2012 & A4:2013 8.6.2
© 3M 2015. All Rights Reserved
Sterilization Monitoring - not as simple as it looks!
Is it done yet?
18/11/2015
16
© 3M 2015. All Rights Reserved
Standardize the process
Checklists - outline all the steps
Automate the process
Reduce the number of steps and handoffs
Redundancy (double checks)
Design the sterilization process to prevent error and break the chain of infection? (SCARR)
© 3M 2015. All Rights Reserved
• Monitoring and verifying the cleaning process• Sterilization process monitoring
• monitoring of every package and sterilization load • routine monitoring of sterilizer efficacy • qualification testing of the sterilizer after installation,
relocation, sterilizer malfunction, major repairs, and sterilization process failures
• periodic product quality assurance testing
Reprinted from ANSI/AAMI ST79:2010 & A1:2010 &A2:2011 & A3:2012 &A4:2013 Clause 10.4, Table 6, 10.6 – 10.9
Quality Control
© 3M 2015. All Rights Reserved
• Probability
• Assurance level of 10-6
• Individual sterilization monitors does not indicate sterility
• Need the combination of all monitors to give an assurance of sterility
• Physical + Chemical + Biological = Probability of sterility
(1 in a million chance that an item is not sterile)
Sterilization Assurance
18/11/2015
17
© 3M 2015. All Rights Reserved
Ensure probability of sterility of processed medical devices
Detect sterilization failure ASAP: quarantine medical devices until final BI result known
Verify a corrected failure ASAP…… get sterilizer back into service
Control costsRemove medical devices involved
in failures before patient useHelps determine if events during
sterilization process met parametersProvides verification of adherence
to policies/proceduresPromote patient safety and improve
outcomes
Reasons for Testing the Sterilization Process
© 3M 2015. All Rights Reserved
• Each monitoring tool “plays a distinct and specific role in sterilization process monitoring, and each is indispensable to sterility assurance.”
• Physical monitors– time, temperature and pressure recorders, displays, digital printouts,
tapes and gauges
• Chemical indicators (CIs) - (Classes 1-6)
– external/internal CIs
– Bowie-Dick (BD) type tests
• Biological indicators (BIs)
Reprinted from ANSI/AAMI ST79:2010 & A1:2010 &A2:2011 & A3:2012 & A4:2013 Clause 10.4, Table 6 & 7
Sterilization Process Monitoring Devices
© 3M 2015. All Rights Reserved
BIOLOGICAL INDICATOR MONITORING
Biological indicators provide the only direct measure of the lethality of the sterilization process.
18/11/2015
18
© 3M 2015. All Rights Reserved
• Guideline for Disinfection and Sterilization in Healthcare Facilities, 2008
• “Biological indicators are recognized by most authorities as being closest to the ideal monitors of the sterilization process because they measure the sterilization process directly by using the most resistant organisms (i.e., Bacillus spores) and not by merely testing the physical and chemical conditions necessary for sterilization.”
Ref: http://www.cdc.gov/ncidod/dhqp/pdf/guidelines/Disinfection_Nov_2008.pdf , page 76
CDC Guidelines
© 3M 2015. All Rights Reserved
Routine load release
Testing of each non-implant and implant load
Routine sterilizer efficacy monitoring
Establishing a regular pattern of testing the efficacy of the sterilization process
Sterilizer qualification testing
Testing of the sterilizer after events occur which could affect the ability of the sterilizer to perform
Periodic product testing
Testing of routinely processed items to ensure the effectiveness of the sterilization process and to avoid wet packs
ANSI/AAMI ST79:2010 & A1:2010 &A2:2011 & A3:2012 & A4:2013 Clause 10.5.3, Table 7
Biological Indicator Monitoring
© 3M 2015. All Rights Reserved
• Process challenge device (PCD)
designed to simulate the product to be sterilized
constitutes a defined resistance to a sterilization process and used to assess effective performance of the process
placed in the most challenging area in the sterilizer for sterilant penetration
• BI
• BI and a Class 5 integrating chemical indicator
• Class 5 integrating chemical indicator
• Class 6 Emulating Indicator
Reprinted from ANSI/AAMI ST79:2010 & A1:2010 &A2:2011 & A3:2012 & A4:2013 Clause 10.5.4
Sterilization Process Monitoring Devices
18/11/2015
19
© 3M 2015. All Rights Reserved
• Routine load release • non-implant• implant load
• Routine sterilizer efficacy monitoring• Establishing a regular pattern of testing the
efficacy of the sterilization process for both gravity and dynamic air-removal testing.
• BI PCD• Every load • Daily plus every implant load• Weekly plus every implant load
• BD type test• Daily
• Immediate Use Steam Sterilizer (IUSS)• BI PCD representative of tray
routinely processed• Each type of tray configuration in
routine use should be tested separately• Perforated, mesh bottom, open surgical tray• Rigid sterilization container system• Protective organizing case• Single-wrapped surgical tray • Empty load on bottom shelf over drain
• BD type test if dynamic-air-removal• Daily
Reprinted from ANSI/AAMI ST79:2010 & A1:2010 &A2:2011 & A3:2012 & A4:2013 Clause 10.6.1, 10.6.2, Table 6 & 7
Routine Sterilizer Efficacy Monitoring
© 3M 2015. All Rights Reserved
• Table-top sterilizers• BI PCD representative of package or tray routinely processed and
most difficult to sterilize
• BI PCD should contain items normally present during routine sterilization
• Full load in cold point (check with sterilizer manufacturer)
Routine Sterilizer Efficacy Monitoring
© 3M 2015. All Rights Reserved
• Weekly, preferably daily
• Every load with an implant
• Some sterilization systems (e.g., Ethylene Oxide) require every load monitoring
• Why monitor every load?• Universal standard of patient care • Cost and impact of a recall• To be certain all implants, including
those in loaners, are appropriately monitored
• Ensure every type of sterilization cycle used is monitored
• Ensure every type of packaging used in flash sterilization is monitored
• Reduce risk and cost of healthcare-associated infections (HAIs)
ANSI/AAMI ST79:2010 & A1:2010 &A2:2011 & A3:2012 & A4:2013 Clause 10.5.4
Biological Indicator - Monitoring Frequency
18/11/2015
20
© 3M 2015. All Rights Reserved
• Physical monitors
• External process indicator (Class 1) on every package
• Internal CI (Class 3, 4, 5 or 6) inside every package
• If desired, a PCD containing a
• BI
• BI and a Class 5 integrating chemical indicator
• Class 5 integrating chemical indicator
• Class 6 Emulating Indicator
• Evaluation of all data by an experienced, knowledgeable person
• Do not distribute load if any data suggests a sterilization process failure
• If desired, a PCD containing a • BI
• If a BI PCD is not used in each load• Do not know spores were killed
• Need to do a recall when a positive BI is obtained
• More frequent monitoring less to recall and reduce chance of patient receiving a non-sterile medical device
• Immediate Use Steam Sterilization Cycles (IUSS)
• Class 5 or Class 6 PCD for Releasing IUSS Loads
• Representative of load
• Open surgical tray
• Rigid sterilization container
• Protective organization case
• Use as internal CI and to release non-implant loads
ANSI/AAMI ST79:2010 & A1:2010 &A2:2011 & A3:2012 & A4:2013 Clause 10.5.4
Routine Load Release-Non-Implant Loads
© 3M 2015. All Rights Reserved
What is an Implant?According to FDA, “device that is placed into a surgically or naturally formed cavity of the human body if it is intended to remain there for a period of 30 days or more. FDA may, in order to protect public health, determine that devices placed in subjects for shorter periods are also ‘implants.’ ” 21 CFR 812.3(d)
•Only BI results can be used to release implants
•“BIs within a PCD should be used to monitor every load containing implants (see 10.6.1).”•The PCD should include a Class 5 integrating CI
•“The load should be quarantined until the results of the BI testing are available (CDC, 2008).”
ANSI/AAMI ST79:2010 & A1:2010 &A2:2011 & A3:2012 & A4:2013 10.6.3
Routine Load Release-Implant Loads
• Immediate use steam sterilization (IUSS) should not be used for implantable devices except in cases of emergency when no other option is available.
© 3M 2015. All Rights Reserved
• Name of
• Implant prematurely released
• Patient
• Surgeon
• Reason for premature release
• What could have prevented premature release
ANSI/AAMI ST79:2010 & A1:2010 &A2:2011 & A3;2012 & A4:2013 Annex L
Sample - Implant Exception Form
18/11/2015
21
© 3M 2015. All Rights Reserved 61
Polling question
How often does your Sterile Processing Department monitor with a biological indicator?a. Every loadb. Once a dayc. Daily plus implantsd. Once a week
© 3M 2015. All Rights Reserved 62
Other Required Testing
• Dynamic-air removal sterilizers
• Bowie-Dick type test –run three consecutive cycles in an empty chamber, one right after the other, with the each test result demonstrating sufficient air removal
• Table-top sterilizers• BI PCD representative
of package or tray routinely processed and most difficult to sterilize
• BI PCD should contain items normally present during routine sterilization
• Full load in cold point (check with sterilizer manufacturer)
• Three consecutive cycles
• For both gravity-displacement and dynamic-air-removal sterilizers
• Steam sterilizer installation, relocation, or repaired and the time it is released for use in the health care facility.
• Three consecutive cycles should be run, one right after the other, with a BI PCD
ANSI/AAMI ST79:2010 & A1:2010 &A2:2011 & A3:2012 & A4:2013 10.8.1, 10.8.2
© 3M 2015. All Rights Reserved 63
Other Required Testing • Immediate Use Steam Sterilization (IUSS)
• BI PCD representative of tray routinely processed• Select a tray configuration to be tested
• Perforated, mesh bottom tray, open surgical tray
• Rigid sterilization container system
• Protective organizing case
• Single-wrapped surgical tray
• Empty load on bottom shelf over drain
• Three consecutive cycles
ANSI/AAMI ST79:2010 & A1:2010 &A2:2011 & A3:2012 & A4:2013 10.8.3 &10.8.4
18/11/2015
22
© 3M 2015. All Rights Reserved
STERILE STORAGE
Sterile items should be stored in a manner that reduces the potential for contamination.
© 3M 2015. All Rights Reserved
• Separate area with restricted access• Proper ventilation (at least 4 air
changes/hour, positive pressure to corridor) to protect against dust, moisture and extremes of temperature (~24ºC /75ºF) and humidity (<70%)
• Free of insects and vermin• Sterile items should be stored away from
outside walls (at least 2 inches), off the floor (at least 8-10 inches) and away from the ceiling (18 inches)
• Stored to prevent physical damage (dragging, sliding, crushing, bending, compressing or puncturing)
• Sterile packages should be minimally handled to reduce the risk of contamination of the contents
• Should not be stored next to sinks or under exposed water or sewer pipes or in locations where they may become wet
• Should not be stored on floor or windowsills
• Shelf life is event related• Sterile packages transported to the point
of use should be protected to prevent contamination
ANSI/AAMI ST79:2010 & A1:2010 &A2:2011 & A3:2012 & A4:2013 8.9
Sterile Storage
© 3M 2015. All Rights ReservedANSI/AAMI ST79:2010 & A1:2010 & A2:2011 & A3:2012, A4:2013 Section 8.9.2
Protect Clean and Sterile Supplies from Contamination
NO OUTSIDE SHIPPING CONTAINERS OR CORRUGATED CARDBOARD / CARTONS
* Photo courtesy of Department of Entomology, University of Nebraska-Lincoln.
Photographer: Jim Kalisch.
Mature Indian Meal Moth Larvae Pupating in Corrugated Cardboard*
Quality in the Sterile and Clean Storage Area
18/11/2015
23
© 3M 2015. All Rights Reserved
RECORD KEEPING
© 3M 2015. All Rights Reserved
Labeling on product•Lot or load control number
– Date of processing
– Sterilizer number
– Cycle number
Expiration date or statement:
“Contents sterile unless package is open or damaged. Please check before using.”
Electronic system• Reduction of human error
• Past records available with a touch of a finger
• Accessibility to all load records at any time
• All load information in one location
ANSI/AAMI ST79:2010 & A1:2010 &A2:2011 & A3:2012 & A4:2013 8.3.2
Documentation - Manual or Electronic
© 3M 2015. All Rights Reserved
• Sterilizer and load records Load contents Date and time of cycle Exposure time and temperature Initials of operator Biological results Chemical indicator results
• Records of sterilizer repair, maintenance and calibration• Maintain records for time determined by risk manager
Documentation - Electronic or Manual
18/11/2015
24
© 3M 2015. All Rights Reserved
RECALL PROCEDURES
Risk Communication
© 3M 2015. All Rights Reserved 71
Recall Procedures• Written policies and procedures for the
recall of items from issued or stored loads should be developed in cooperation with the infection prevention and control committee and risk management of the individual health care facility.
• These policies and procedures should be documented, and records should be maintained.
• If cause of failure immediately identified and confined to one load or item
– e.g., using incorrect sterilization cycle
– No recall, correct problem and reprocess load
•If cause of failure not identified•Quarantine load, recall all items processed since last negative BI
•Determine cause of failure
ANSI/AAMI ST79:2010 & A1:2010 &A2:2011 & A3:2012 & A4:2013 10.11.1
© 3M 2015. All Rights Reserved 72
Polling question
How many times in the last 12 months has your facility conducted a recall?a. 0b. 1-2c. 2 or mored. Not sure
18/11/2015
25
© 3M 2015. All Rights Reserved
Areas of Concern
© 3M 2015. All Rights Reserved 74
Areas of Concerns that Impact Infection Prevention
• Processing of endoscope• Inadequate processing
• Culturing of endoscope
• Cleaning verification • How clean is visibly clean?
• Immediate Use Steam Sterilization
• Toxic Anterior Segment Syndrome (TASS)• “Most cases of TASS appear to result from
inadequate instrument cleaning and sterilization”
• Loaner instrumentation• Timelines not met to allow for proper
processing
• Product testing• Product testing should always be performed
when major changes are made in packaging, wraps, or load configuration, such as dimensional changes, weight changes, or changes in the type or material of packaging or wrapper.”
ANSI/AAMI ST79:2010 & A1:2010 &A2:2011 & A3:2012 & A4:2013 10.9
© 3M 2015. All Rights Reserved
• Infection Preventionist collaboration with the Sterile Processing Department (SPD) is key
• Include SPD in your Joint Commission tracer and rounding activities
• Ensure that all policies and procedures are evidence-based and up to date
• Quality does not automatically translate into patient safety
• Monitoring of the sterilization process is necessity for maintaining patient safety
• Be aware of publications in the media that impacts patient safety, healthcare environment and perioperative setting including the Sterile Processing Department
• Conduct regular risk assessments of the various processes and potential problems using tools such as FMEA and RCA when issues arise that impact patient safety
• Be aware of the concerns in the SPD
Summary
18/11/2015
26
© 3M 2015. All Rights Reserved
CMSOSHA
The Joint Commission State Regulators
http://www.amusingtime.com/funny-dog-stuck-between-two-trees-2/
© 3M 2015. All Rights Reserved© 3M 2015. All Rights ReservedSM
77
Thank you!
Questions?
© 3M 2015. All Rights Reserved 78
Next Month’s Webinar
Hot Topics from the 3M Sterilization Tech Line• December 10, 2015
18/11/2015
27
© 3M 2015. All Rights Reserved
Acknowledgments
• SPD staff pictures used with permission.
• Reprinted from ANSI/AAMI ST79:2010, A1:2010, & A2:2011 & A3:2012 & A4:2013 with permission of Association for the Advancement of Medical Instrumentation, Inc. (C) 2011 AAMI www.aami.org. All rights reserved. Further reproduction or distribution prohibited.
© 3M 2015. All Rights Reserved 80
AAMI Sterilization Standards• ST79 Comprehensive guide to steam sterilization and sterility assurance in health care facilities, 2nd edition (Incorporates Amendment
1:2010, A2,2011, A3:2012, and A4:2013)
• ST58 Chemical sterilization and high-level disinfection in health care facilities, 3rd edition
• ST91 Flexible and semi-rigid endoscope processing in health care facilities
• ST40 Table-top dry heat (heated air) sterilization and sterility assurance in health care facilities, 2nd edition
• TIR34 Water for the reprocessing of medical devices
• ST41 Ethylene oxide sterilization in health care facilities: Safety and effectiveness, 4th edition (Incorporates 2010 Erratum).
• ST81 Information to be provided by the manufacturer for the processing of resterilizable medical devices, 1st edition
• TIR12 Designing, testing, and labeling reusable medical devices for reprocessing in health care facilities: A guide for device manufacturers, 3rd edition
• TIR30 A compendium of processes, materials, test methods, and acceptance criteria for cleaning reusable medical devices, 2nd edition
• TIR55 Human factors engineering for processing medical devices
• TIR63 Management of loaned critical and semi-critical medical devices that require sterilization or high-level disinfection
• ST65 Processing of reusable surgical textiles for use in health care facilities, 2nd edition
• PB70 Liquid barrier performance and classification of protective apparel and drapes in health care facilities, 2ed
• TIR11 Selection of surgical gowns and drapes in health care facilities, 2nd edition
© 3M 2015. All Rights Reserved
How to Purchase AAMI Standards for Your Reference Library
AAMI documents can be purchased through AAMI by credit card using the following four options:
Internet: http://marketplace.aami.org
Call: 1-877-249-8226
Fax: 301-206-9789
Mail: AAMI Publications, P.O. Box 0211, Annapolis Junction, MD 20701-0211
18/11/2015
28
© 3M 2015. All Rights Reserved
References• The Joint Commission: 2015 Accreditation Standards• Joint Commission Perspectives®, April 2015, Volume 35, Issue 4• http://www.jointcommission.org/assets/1/23/Quick_Safety_Issue_Two_May_2014.pdf• CDC Health Advisory Immediate Need for Healthcare Facilities to Review Procedures for Cleaning, Disinfecting, and Sterilizing
Reusable Medical Devices. CDC Health Alert Network. September 11, 2015, 12:15 EDT (12:15 PM EDT) CDCHAN-00382• Association for the Advancement of Medical Instrumentation (AAMI). Comprehensive guide to steam sterilization and sterility
assurance in healthcare facilities. ANSI/AAMI ST79:2010 & A1:2010 &A2:2011 & A3;2012 & A4:2013• Association for the Advancement of Medical Instrumentation (AAMI). Containment devices for reusable medical device sterilization.
ANSI/AAMI ST77:2013• Recommended Practices for Sterilization in the Perioperative Practice Settings. In: Perioperative Standards and Recommended
Practices. Denver, CO: AORN, Inc, 2015• Rutala, William A, Weber, David J and HICPAC Guideline for Disinfection and Sterilization in Healthcare Facilities, 2008
• Brachman, Philip S. Epidemiology of Nosocomial Infections. In Hospital Infections 3rd edition, edited by John V. Bennett and Philip s. Brachman. 1992 pp. 3-20.
• IAHCSMM Central Service Technical Manual, 7th Edition.• http://www.iahcsmm.org/current_issues_Joint_paper_loaner_instrumentation.htm• Seavey, Rose. AAMI Sterile Processing In Healthcare Facilities: Preparing for Accreditation Surveys. AAMI 2011.
© 3M 2015. All Rights Reserved
References• Recommended Practices for Cleaning and Sterilizing Intraocular Surgical Instruments. From the American Society of Cataract and
Refractive Surgery and the American Society of Ophthalmic Registered Nurses. Special Report prepared February 16, 2007.• Occupational Safety and Health Administration. 29 CFR 1910.1030 Occupational Exposure to Bloodborne Pathogens ; Final Rule.
Federal Register December 6, 1991.• Archibald, Lennox K. and Hierholzer, Walter J. Principles of Infectious Diseases Epidemiology. in Hospital Epidemiology and Infection
Control 3rd edition. C. Glen Mayhall, Editor. 2004. Pp.1-17.• Sehulster, Lynn and Schultz, Janet. Central Sterile Supply. In Hospital Epidemiology and Infection Control 3rd edition. C. Glen Mayhall,
Editor. 2004. Pp.1301-1313.• Steam Sterilization – Update on The Joint Commission’s Position. June 16, 2009. • The Joint Commission Perspectives. October 2009 Vol 29 (10)• Reason, James Human error: models and management. BMJ 2000:768-70• Nick Mamalis, MD, Toxic Anterior Segment Syndrome Journal of Cataract and Refractive. Surgery 2006; 32:324-333.• AAMI / FDA Reprocessing Summit. October 2011.
http://www.aami.org/publications/summits/2011_Reprocessing_Summit_publication.pdf• Sterilization and Reprocessing – A Matter of Patient Safety. Horizons Spring 2012• Martha Young (2012) Top 10 Risks in Sterile Processing. Biomedical Instrumentation & Technology: Reprocessing, Vol. 46, No. sp12, pp.
15-19. • Standards of Infection Control in Reprocessing of Flexible Gastrointestinal Endoscopes. SGNA 2012• Guidelines for Use of High Level Disinfectants and Sterilants for Reprocessing Flexible Gastrointestinal Endoscopes. SGNA 2010• Multiple Society guideline on reprocessing flexible gastrointestinal endoscopes: 2011. American Society for Gastrointestinal Endoscopy
and the Society for Healthcare Epidemiology of America.
© 3M 2015. All Rights Reserved
References• http://www.iahcsmm.org/current_issues_Joint_paper_loaner_instrumentation.htm• www.cdc.gov• www.fda.gov• www.epa.gov• www.ecri.org/2015hazards• https://www.ecri.org/Resources/Superbug/Culturing_Duodenoscopes_Key_Step_to_Red
ucing_CRE_Infections.pdf• http://www.cdc.gov/hai/pdfs/lab/interim-duodenoscope-culture-method.pdf• http://www.cdc.gov/hai/pdfs/cre/interim-duodenoscope-surveillance-Protocol.pdf• http://www.cdc.gov/hai/settings/lab/lab-duodenoscope-sampling.html#c