Heavy duty linear solenoid RM 060
Weight:Complete solenoid: appr. 1300 gArmature: appr. 250 g
Standard:Voltage: 24 V DCFlying leads: 20 cm
Insulation class: F (max. permissibletemperature = 155 °C)
Service-free DU armature bearing for maximum durability.
Stroke of version with standard stroke limiter: 12 mm.
Force vs. Stroke diagram F = f (s)
W = horizontal characteristic
Force measured when operating in horizontal position, at 90 % rated voltage and winding at operating temperature
stroke s = 0 corresponds to armature in fully homeposition
100 40 25 15 5 % Perm. duty Cycle (ED)1)
25 60 98 150 381 W Nominal coil power Pn45 17 ms Actuation time (ED)
1) If solenoid is mounted directly onto a flat metalsurface the duty cycle can be extended (pleaseask for advice)
0 5 10 12 15s/mm
F/N
10
20
50
1000 %ED
100
4025
15
5
100
200
500
RM060 Series Linear Solenoid Thrust and/or Pull Type
Doc
umen
t LNSRM6/
15
Rev
isio
n 002
Email: [email protected]: www.impulseautomation.co.uk
Information shown in these data sheets are for guidance purposes only, no liability is accepted for any errors or omissions.The designer or user is solely responsible for the safe and proper use of these parts, assemblies or equipment described.
Impulse Automation LimitedUnited Kingdom
Company Registration 665193
2934
M6
M6
Ø35
18+1
375
415
7
~19
64
718
+1
Ø36
65
8
64152
M6
M5
3019 67
54
Ø5,
8
Ø60
Ø45
Ø35
M6
M6
Ø35
10
18+1
295
415
7
~36
81
18+1
Ø36
82
8
89162
Ø36
M6
M5
3019 67
54
Ø5,
8
Ø60
Ø45
Ø35
Direction of stroke
Direction of stroke
without stroke limiter
with stroke limiter
RM060 Series Linear Solenoid Thrust and/or Pull Type
Doc
umen
t LN
SR
M6/
25
Rev
isio
n 002
Email: [email protected]: www.impulseautomation.co.uk
Information shown in these data sheets are for guidance purposes only, no liability is accepted for any errors or omissions.The designer or user is solely responsible for the safe and proper use of these parts, assemblies or equipment described.
Impulse Automation LimitedUnited Kingdom
Company Registration 665193
Dim
ensions given with
armature in fully hom
e positionD
imensions given w
ith arm
ature in fully home position
Coil terminals
Examples of design types:–––––––>Direction of stroke
–OBOO– –OBLO– –OBOR– –ORRO– –OROR–
–HBOO– –HBLO– –HBOL– –HRRO– –HROR–
RM 060 – W – O R O R – N – 24 V DC 100 % ED Order specificationsRM Linear solenoid series
Design type ø mm060
W Horizontal frontal force vs. stroke output
Description2)
O Stroke limit withoutH with
R Plunger right hand side3)
B both sidesO Flange withoutR right hand side3)
L left hand side4)
O Gaiter withoutR right hand side3)
L left hand side4) 5)
B both sides5)
F Coil terminals Flying leads
N
(20 cm standard length)
plug-in socket connection6)
24 Operating voltage 24 V DC205 205 V DC (connected to
230 V AC with SI- bridgerectifier)
100 % ED Perm. duty cycle under air cooled conditions (LK)
2) See below3) Opposite to electrical connection4) Same side as electrical connection5) Available with stroke limit only6) For plug-in socket 6.3 DIN 46247 and plug
Z801 and Z811
N F
ca.1
2ca
.12
200
+15
RM060 Series Ordering Information
Doc
umen
t LNSRM6/35
R
evis
ion
002
Preferred types competitively priced available on a
quick delivery.
RM060W-OBOO-F-24VDC 100%ED
Email: [email protected]: www.impulseautomation.co.uk
Company Registration 665193Information shown in these data sheets are for guidance purposes only, no liability is accepted for any errors or omissions.The designer or user is solely responsible for the safe and proper use of these parts, assemblies or equipment described.
Impulse Automation LimitedUnited Kingdom
Plug-in socket Z801 Screw joint PG 9
for lead diameter 4.5 - 7 mm
Plug-in socket Z811
Screw joint PG 11 for lead diameter 6 - 9 mmPlug-in socket with built in
Si-bridge rectifier
Flange(Mounting screws are part of the
shipment)
Order specificationAK
ØL
CB
H
ØE
ØF
ØD
ØI
ØJ
ØG
Dimensions (mm) Order
AType B C D E F G H I J K L Type numberZ 840 RM 060 70,0 8,0 13,0 35,0 29,0 35,0 60,5 1,0 5,8 5,3 54,0 45,0 RM 060 Z 840
41,0≈10,0
(30,5)
Ø 1
9,0
5,5
34,2
Dimensions (mm)Order
number
RM060 Series Accessories
Doc
umen
t LN
SR
M6/
45
Rev
isio
n 002
Email: [email protected]: www.impulseautomation.co.uk
Information shown in these data sheets are for guidance purposes only, no liability is accepted for any errors or omissions.The designer or user is solely responsible for the safe and proper use of these parts, assemblies or equipment described.
Impulse Automation LimitedUnited Kingdom
Company Registration 665193
Stroke limiter(Mounting screws are part of theshipment)
Order specification
Fork
ØA
ØF
ØE
ØB
GH
D
C
KI
ØJ
A
C
F
G
E
ØD
B
Dimensions (mm) Order
A B C D E F G H I J K Type number
Z 845 RM 060 60,0 45,0 22,0 17,0 29,0 35,0 5,5 12,0 M5 5,3 10,0 RM 060 Z 845
Order-number
A B C D E F Connec-tion G
36.304 27 34 19 6 6 12 M6
Dimensions (mm)Order
number Type
RM060 Series Accessories
Doc
umen
t LN
SR
M6/
55
Rev
isio
n 002
Email: [email protected]: www.impulseautomation.co.uk
Information shown in these data sheets are for guidance purposes only, no liability is accepted for any errors or omissions.The designer or user is solely responsible for the safe and proper use of these parts, assemblies or equipment described.
Impulse Automation LimitedUnited Kingdom
Company Registration 665193