Transcript
Page 1: 7 Coatings - fdotwp1.dot.state.fl.us · 2 years when properly stored - MasterSeal 915: 1 year when properly stored Master Builders Solutions by BaSF Technical Data Guide. technical

VOC COntent•MasterSealM200:

–Self-levelinggrade:196g/Llesswaterandexemptsolvents

–Flash/slopegrade:203.3g/Llesswaterandexemptsolvents

•MasterSealTC225:209g/Llesswaterandexemptsolvents.

Polyurethane waterproofing, traffic-bearing membrane systems for vehicular and pedestrian areasForMerLySonoguard®

071800traffic Coatings7

PRODUCt HIGHLIGHtS•Primercoatnottypicallyrequiredwhichhelpstoreducelaborandmaterialcosts

•Waterproofwhichhelpstoprotectconcretefromfreeze/thawdamage;protectsoccupiedareasbelowfromwaterdamage

•excellentchlorideresistanceprovidesprotectionagainstchlorideintrusion;extendsthelifeofreinforcingsteel

•Seamlesselastomericmembraneoffersexcellentdurabilityandsuperiorabrasionresistance,hasnoseamsthatmayresultinleaks

•Skidresistanttoincreasesafety•Multiplesystemsavailable,makingMasterSealTraffic1500idealforvariousvehicularorpedestriantrafficsolutions

•repairableandrecoatabletoextendtheusefullifeofthesystem

MasterSeal® Traffic 1500

DeSCRIPtIOnMasterSealTraffic1500waterproofingsystemsarecomposedof:

–MasterSealM200,aone-component,moisture-curingpolyurethane,–MasterSealTC225,aone-componentaliphaticmoisture-curingpolyurethane,–MasterSealTC225TintBase,consistingof40standardcolors,(seeFormno.1017936).

Forprojectsrequiringprimer,twochoicesareavailable:–MasterSealP222,aone-componentsolvent-basedprimerandsealer,–MasterSealP220,atwo-componentwaterborneepoxyprimerandsealer.

PaCkaGInG- MasterSealP222:5gallon(18.93L)pails

- MasterSealP220:4gallon(15.14L)unitsin5gallonpails(18.93L)

- MasterSealM200,(self-levelingandslope-grade):- 5gallon(18.93L)pails-55gallon(208L)drums

-MasterSealTC225:-5gallon(18.93L)pails-55gallon(208L)drums

-MasterSeal914:1pint(473mL)cans-MasterSeal915(forrecoatapplications):0.5pint(236mL)cans

YIeLD Seechartonpage3

COLORS gray,Charcoal,Tan,darkTan

StORaGe Storeinunopenedcontainersinacool,clean,dryarea

SHeLf LIfe- MasterSealM200andTC225: 5galpails,1yearwhenproperlystored 55galdrums,9monthswhenproperlystored

-MasterSeal914,pintcans:2yearswhenproperlystored

-MasterSeal915:1yearwhenproperlystored

MasterBuildersSolutionsbyBaSFwww.master-builders-solutions.basf.us

Technical Data Guide

Page 2: 7 Coatings - fdotwp1.dot.state.fl.us · 2 years when properly stored - MasterSeal 915: 1 year when properly stored Master Builders Solutions by BaSF Technical Data Guide. technical

technical Data CompositionMasterSealTraffic1500isamoisture-curingpolyurethanemembrane.

Compliances•uL790ClassaFirerating•aSTMC957•aSTMe108•aSTMe84

Weight per gallon, lbs(kg) 9.9(4.5) 9.1(4.1) aSTMd1475

Specific gravity, kg/L 1.19 1.09

Solids aSTMd1259 Byweight,% 84 77 Byvolume,% 81 75

Viscosity, cps 4,000–9,000 2,000–4,000 aSTMd2393

flash Point, °F(°C) 104(40) 105(40.5) aSTMd56

*uncuredmaterial

Hardness, Shorea 60 89 aSTMd2240

tensile strength, psi(MPa) 752(5.2) 2,500(17.2) aSTMd412

elongation, % 595 502 aSTMd412

tear strength, PIT 74 199 aSTMd1004

Weight loss, % 16 17 Max:40

Low temperature flexibility noCracking noCracking noCrackingand crack bridging

adhesion in peel after water immersion,pli, Primedmortar 43 n/a 5 Plywood 34 n/a 5

adhesion (Pull-off), psi BaseCoat 275 aSTMd4541

ethylene glycol 88 92 Min:70

Mineral spirits 47 60 Min:45

Water 96 83 Min:70

Testresultsareaveragesobtainedunderlaboratoryconditions.reasonablevariationscanbeexpected.

elongation recovery, % 94 Min:90

tensile retention,% 151 Min:80

elongation retention, % 94 Min:90

abrasion resistance,mglost;(aSTMd4060) 1—systempasses Max:50CS-17Wheel,1,000gload,1,000cycles

Crack bridging, 1,000cycles Systempasses —

test Data

ProPerTy* reSuLTS TeSTMeThod

M200 TC225

ProPerTy reSuLTS TeSTMeThod/

M200 TC225 requIreMenTS

CheMICaL reSuLTS requIreMenTS

M200 TC225

CheMICaL reSuLTS requIreMenTS

DECK COATING VALIDATION

Issued to: BASF Corp.Product: Sonoguard Base Coat & Sonoguard Top Coat

ASTM D 412: Tensile Strength of Top Coat Sonoguard Top Coat Tensile Strength: 2,707 psi; Elongation: 699%

ASTM D 4541: Adhesion of Base Coat Sonoguard Base Coat Pull-off Adhesion: 539 psi

ASTM D 4060: Abrasion Resistance of Top Coat Sonoguard Top CoatAbrasion Resistance: .30 mgms loss – mgms loss/1,000 cycles

Validation Date: 3/7/13 – 3/6/18

No. 313-SON318 Copyright © 2013

ProPerTIeSoFCuredMeMBraneS

CheMICaLreSISTanCeTenSILereTenTIon(aSTMC957)

MaSTerSeaLTraFFIC1500SySTeMWeaTherIngreSISTanCeandeLongaTIonreCovery(aSTMC957)

TechnicaldataguideMasterSeal® traffic 1500

Page 3: 7 Coatings - fdotwp1.dot.state.fl.us · 2 years when properly stored - MasterSeal 915: 1 year when properly stored Master Builders Solutions by BaSF Technical Data Guide. technical

Weight per gallon, lbs(kg) 9.9(4.5) 9.1(4.1) aSTMd1475

Base coat Wetmils(mm) 25(0.6) 25(0.6) 25(0.6) drymils(mm) 20(0.5) 20(0.5) 20(0.5) Coverage1 60(1.5) 60(1.5) 60(1.5)

Mid coat Wetmils(mm) none 20(0.5) 25(0.6) drymils(mm) none 15(0.4) 20(0.5) Coverage1 none 80(2.0) 60(1.5)

finish coat Wetmils(mm) 25(0.6) 20(0.5) 20(0.5) drymils(mm) 20(0.5) 15(0.4) 15(0.4) Coverage1 60(1.5) 80(2.0) 80(2.0)

aggregate2 lbsper100ft2 10–15 30–50 50–70 (kg/m2) (0.5–0.7) (1.5–2.5) (2.5–3.4)

Coverageratesareapproximateandmayvaryduetotheapplicationtechniqueused.actualcoverageratewillalsodependonfinishandporosityofthesubstrate.1Coverageisft2/gal(m2/L)2(16–30meshroundedsilicasandorproportionalequivalent)

2.dynamiccracksandjoints1⁄16"(1.6mm)andgreaterwidemustberoutedtoaminimumof1/4by1/4"(6by6mm)andcleaned.Installbondbreakertapetopreventadhesionofsealantstothebottomofjoint.PrimejointfacesonlywithMasterSealP173(seeFormno.1017962).Filljointsdeeperthan1/4"(6mm)withappropriatebackerrodandMasterSealSL1™/SL2™(slopegradeorself-leveling)orMasterSealnP1™/nP2™sealants(seeFormnos.1017903and1017911).Forcracks,sealantshouldbeflushwiththeadjacentconcretesurface.Forexpansionjoints,sealantshouldbeslightlyconcave.

3.Sealedjoints1"(25mm)orlesscanbecoatedoverwithMasterSealTraffic1500.expansionjointsexceeding1"(25mm)wideshouldnotbecoatedoverwithMasterSealTraffic1500sothattheycanperformindependentlyofthedeckcoatingsystem.

test Data, cont.

2.repairvoidsanddelaminatedareaswithBaSFbrandedcementitiousandepoxypatchingmaterials.Forapplicationwhenfast-turnrepairsarerequired,MasterSealM265canbeusedtorepairpatchesupto1"(25mm)indepth.PleaserefertoTechnicalServiceforproperapplicationtechniques.

3.allunitsmustbeappliedwithinthespecifiedpotlife.

SurFaCePre-STrIPInganddeTaILIng1.Fornonmovingjointsandcrackslessthan1⁄16"(1.6mm)wide,applyprimerwhenrequired,followedby25wetmils(0.6mm)pre-stripingofMasterSealM200.MasterSealM200mustbeappliedtofillandoverlapthejointorcrack3"(76mm)oneachside.Feathertheedges.

HOW tO aPPLYSURfaCe PRePaRatIOnConCreTe

1.Concretemustbefullycured(28days),structurallysound,cleananddry(aSTMd4263).allconcretesurfaces(newandold)mustbeshotblastedtoremovepreviouscoatings,laitanceandallmiscellaneoussurfacecontaminationandtoprovideprofileforproperadhesion.abrasiveshotblastingmustoccurafterconcreterepairhastakenplace.acid-etchingisnotpermitted.ProperprofileshouldbeaminimumofICrICSP-3(asdescribedinICrIdocument03732.)

LIghTToMedIuM heavyduTy exTraheavyduTy

TraFFIC&PedeSTrIan (reFuSaLMeThod) (reFuSaLMeThod)

InDUStRIeS/SeCtORS•Stadiums•Balconies•Parkinggarages•CommercialConstruction•Buildingandrestoration

MasterBuildersSolutionsbyBaSFwww.master-builders-solutions.basf.us

Page 4: 7 Coatings - fdotwp1.dot.state.fl.us · 2 years when properly stored - MasterSeal 915: 1 year when properly stored Master Builders Solutions by BaSF Technical Data Guide. technical

4.Cuta1/4by1/4"(6by6mm)keywayintotheconcretewherethecoatingsystemwillbeterminatedifnowall,joint,orotherappropriatebreakexists.Fillaccordingtoinstructionsoncracksandjointsover1⁄16"(1.6mm)wide.

5.Formasealantcantintothecorneratthejunctionofallhorizontalandverticalsurfaces(wallsections,curbs,columns).PrimewithMasterSealP173andapplya1/2–1"(13–25mm)widebeadofMasterSealnP1orMasterSealnP2sealants.Tooltoforma45°cant.

6.Inlocationsofpotentialhighmovement,suchaswallandslabintersections,apply25wetmils(0.6mm)ofMasterSealM200andembedMasterSeal955.

MeTaLSurFaCeS1.removedust,debris,andanyothercontaminantsfromvent,drain-pipeandpostpenetrations,regletsandothermetalsurfaces.

2.CleanthesesurfacestobrightmetalandprimeimmediatelywithMasterSealP173.

3.ProvideappropriatecantwithMasterSealnP1,nP2orCr195sealanttoeliminate90°angles.

PLyWood1.allplywoodmustbesmooth-faced,aPa-stampedandexteriorgrade.Constructionmustconformtocode,butplywoodmustnotbelessthan15⁄32"

(12mm)thick.Plywoodspacingand

deckconstructionmustfollowaPaguidelines.2.Surfacesmustbefreeofcontaminants.Primingisnotnecessaryonclean,dryplywood.

3.allseamsmustbecaulkedwithMasterSealnP1orMasterSealnP2sealants(seeFormnos.1017906and1017911).Pre-stripe4–6"(102–152mm)widewith25wetmils(0.6mm)ofM200.reinforceallseamsbetweenplywoodsheetsandbetweenflashingandtheplywooddeckbyembeddingMasterSeal995intothepre-striping.

aPPLICatIOn Of PRIMeRPrimernoTe:Whenprimerisrequiredonajob,followthesesteps.WhenapplyingTraffic1500withoutusingaprimer,proceedtoapplication.

1.afterthoroughlyvacuumingthesurface,applyMasterSealP222orP220toalltheproperlyprepareddecksurfacesattherateof200–250ft2/gal(4.9–6.1m2/L).usingarollerpanandashort-tomedium-naprollercover,forcetheprimerintoporesandvoidstoeliminatepinholes.donotapplyoverpre-striping.useonlysolvent-resistanttoolsandequipment.

2.allowprimertodryuntiltack-free.M200mustbeappliedthesameworkingday.

MaSTerSeaLM2001.allpreparatoryworkmustbecompletedbeforeapplicationbegins.Becertainthesubstrateisclean,dry,stableandproperlyprofiled.Sealantsandpre-stripingshouldbeproperlycured.applythebase,midandfinishcoatswithaproperlysizedsqueegeetoarriveattherequiredmilthicknesses.

2.Thebestmethodtoensuretheproperwetfilmthicknessistheuseofagridsystem.dividethesurfacetobecoatedintogridsandcalculatethesquarefootageofeach.refertothecoveragecharttodeterminethequantityofMasterSealTraffic1500neededforeachgridtoarriveattherequiredmilthicknesses.Forexample,onepailofMasterSealM200willcoveranareaapproximately300ft2(28m2),oragrid30by10ft(9by3m)at25wetmils(0.6mm).Themilthicknessofallcoatscanalsobeverifiedbytheuseofawet-milthicknessgauge.

3.applyMasterSealM20025wetmilsthick(0.6mm)usingapropernotchedsqueegeetoentiredecksurface,andbackroll,overcoatingtheproperlypreparedcracks,jointsandflashings.Forslopedareas,useslope-gradeMasterSealM200.donotcoatexpansionjointsover1"(25mm)wide.

4.allowcuringtimeofovernight(16hourminimum).Slightlyextendthecuringtimeincoolordryweatherconditions.ThesurfaceofMasterSealM200shouldhaveaslighttack.Ifthecoatinghasbeenexposedforaprolongedperiod,consultTechnicalServiceforrecommendations.

aPPLICatIOn MetHODS Of SYSteMSMasterSealTraffic1500canbeinstalledinseveralconfigurations,dependinguponthedegreeoftraffictowhichthesystemisexposed.Inareasofextremetraffic(turninglanes,paybooths,entrancesandexits),applytheextraheavy-dutyTrafficSystem.Thefollowingsummarybrieflydescribeseachconfiguration.allcoverageratesareapproximate.

LIghT-ToMedIuM-duTyTraFFIC&PedeSTrIanSySTeM

1.Primeconcretesubstrate(ifrequired).2.apply25wetmils(0.6mm)MasterSealM200usingapropernotchedsqueegeeat60ft2/gal(1.5m2/L).ImmediatelybackrolltolevelMasterSealM200.allowtocureovernight.

3.apply25wetmils(0.6mm)MasterSealTC225usingapropernotchedsqueegeeat60ft2/gal(1.5m2/L).ImmediatelybackrolltolevelMasterSealTC225material.Whilethecoatingisstillwet,broadcastMasterSeal941orequivalent16–30roundedsilicasandat10–15lbs/100ft2(0.5–0.7kg/m2),thenbackrollintothecoatingtofullyencapsulate.

heavy-duTyTraFFICSySTeM1.Primeconcretesubstrate(ifrequired).2.apply25wetmils(0.6mm)MasterSealM200usingapropernotchedsqueegeeat60ft2/gal(1.5m2/L).ImmediatelybackrolltolevelMasterSealM200.allowtocureovernight.

3.apply20wetmils(0.5mm)MasterSealTC225usinganotchedsqueegeeat80ft2/gallon(2.0m2/L).ImmediatelybackrolltolevelMasterSealTC225.Thenextstep,#4,canutilizeeithermethoddescribedin4aor4B.

TechnicaldataguideMasterSeal® traffic 1500

Page 5: 7 Coatings - fdotwp1.dot.state.fl.us · 2 years when properly stored - MasterSeal 915: 1 year when properly stored Master Builders Solutions by BaSF Technical Data Guide. technical

5.removealllooseaggregate,thenapply20wetmils(0.5mm)MasterSealTC225usingaflatsqueegeeat80ft2/gallon(2.0m2/L).ImmediatelybackrolltoevenlylevelMasterSealTC225.

6.Foradditionalslipresistance,immediatelybroadcastMasterSeal941orequivalentatarateof7–10lbsper100ft2(.34–.49kg/m2)andbackrolltoencapsulate.

MOCkUPProvidemockupofatleast100ft2(9.3m2)toincludesurfaceprofile,sealantjoint,crack,flashingandjuncturedetailsandallowforevaluationofslipresistanceandappearanceofMasterSealTraffic1500system.

1.Installmockupwithspecifiedcoatingtypesandwithothercomponentsnoted.

2.Locatewheredirectedbyarchitect.3.Mockupmayremainaspartofworkifacceptabletoarchitect.Forrecoatapplications,seeMasterSealTraffic1500technicalbulletin#24.

CURInG tIMeallowcuringtimeof72hoursbeforevehicularuseand48hoursbeforepedestrianuse.extendthecuringtimeincool-weatherconditions.ToreducethetimeperiodinwhichMasterSealTraffic1500mightbevulnerabletoinclementweatherortoreducethetimebetweencoats,useMasterSeal914.

MaIntenanCe1.Portionsofthemembranethatexhibitwearareconsideredamaintenanceitem,andarenotconsideredawarrantableitem.

2.Surfacesmaybecleanedwithcommercialdetergents.BaSFrecommendsthatamaintenanceagreementbeestablishedbetweentheownerandapplicator.

3.Periodicinspectionandrepairofdamagedsurfaceswillgreatlyprolongtheperformanceandlifeofthesystem.

4.removeallsharpdebrissuchassand,gravelandmetalonaregularbasistoavoiddamagetothecoating.

5.Whenremovingsnow,avoidtheuseofmetalbladesorbucketsthatmaydamagethecoating.

4a. aggregaTeToreFuSaLMeThodImmediatelybroadcastMasterSeal941orequivalent16–30mesh,roundedsilicasandintothewetcoatingattherateof30–50lbsper100ft2(1.0–1.25kg/m²).Immediatelyaftertheaggregatebroadcastandwhilethecoatingisstillwet,blowanyexcessaggregateviaaportableblowerforwardintothewetcoating.donotoverapplyaggregate;itisacceptabletohavelocalizedwetspotsintheaggregatesurfaceaftercompletionofthismethod.Thisprocessrequirescoordinationbetweenallofthemembersintheworkcrew.Thebloweroperator,wearingcleanspikedshoes,shouldblowtheexcessaggregateforwardtowardsthefreshlyappliedandbackrolledtopcoat.Inthismethod,thecoatingshouldnotacceptadditionalsand,minimalexcessaggregateisonthesurface,lessaggregateisusedandthetexturedappearanceshouldbefairlyuniform.

4B.BroadCaSTandBaCKroLLMeThodImmediatelybroadcastMasterSeal941orequivalent16–30mesh,roundedsilicasandintothewetcoatingandbackrolltoencapsulatetheaggregate.evenlybroadcastaggregateattherateof10–15lbsper100ft2(0.5–0.75kg/m²).allowtocureovernight.

5.removealllooseaggregate,thenapply20mils(0.5mm)MasterSealTC225usingaflatsqueegeeat80ft2pergallon(2.0m2/L).ImmediatelybackrolltolevelMasterSealTC225.

6.Foradditionalslipresistance,immediatelybroadcastMasterSeal941orequivalent16–30roundedsilicasandatarateof7–10lbsper100ft2(.34–.49kg/m2)andbackrolltoencapsulate.

exTra-heavyduTySySTeM1.Primeconcretesubstrate(ifrequired).2.apply25wetmils(0.6mm)MasterSealM200usingapropernotchedsqueegeeat60ft2/gal(1.5m2/L).ImmediatelybackrolltolevelMasterSealM200.allowtocureovernight.

3.apply25wetmils(0.6mm)MasterSealTC225usingapropernotchedsqueegeeat50ft2/gal(1.2m2/L).ImmediatelybackrolltolevelMasterSealTC225.Thenextstep,#4,canutilizeeithermethoddescribedin4aor4B.

4a.aggregaTeToreFuSaLMeThodImmediatelybroadcastMasterSeal941orequivalent16–30mesh,roundedsilicasandintothewetcoatingattherateof20–25lbsper100ft2(1.0–1.25kg/m²).Immediatelyaftertheaggregatebroadcastandwhilethecoatingisstillwet,blowanyexcessaggregateviaaportableblowerforwardintothewetcoating.donotoverapplyaggregate;itisacceptabletohavelocalizedwetspotsintheaggregatesurfaceaftercompletionofthismethod.Thisprocessrequirescoordinationbetweenallofthemembersintheworkcrew.Thebloweroperator,wearingcleanspikedshoes,shouldblowtheexcessaggregateforwardtowardsthefreshlyappliedandbackrolledtopcoat.Inthismethod,thecoatingshouldnotacceptadditionalsand,minimalexcessaggregateisonthesurface,lessaggregateisusedandthetexturedappearanceshouldbefairlyuniform

4B.BroadCaSTandBaCKroLLMeThodImmediatelybroadcastMasterSeal941orequivalent16–30mesh,roundedsilicasandintothewetcoatingandbackrolltoencapsulatetheaggregate.evenlybroadcastaggregateattherateof10–15lbsper100ft2(0.5–0.75kg/m²).allowtocureovernight.

MasterBuildersSolutionsbyBaSFwww.master-builders-solutions.basf.us

Page 6: 7 Coatings - fdotwp1.dot.state.fl.us · 2 years when properly stored - MasterSeal 915: 1 year when properly stored Master Builders Solutions by BaSF Technical Data Guide. technical

HeaLtH, SafetY anD enVIROnMentaL read,understandandfollowallSafetydataSheetsandproductlabelinformationforthisproductpriortouse.TheSdScanbeobtainedbyvisitingwww.master-builders-solutions.basf.com,[email protected](800)433-9517.useonlyasdirected.for medical emergencies only, call Chemtrec® 1(800)424-9300.

CLean UPCleanalltoolsandequipmentwithMasterSeal990orxylene.

fOR BeSt PeRfORManCe•Concreteshouldhaveaminimumcompressivestrengthof3,000psi(20.7MPa)andbecuredforaminimumof28days.

•ForslabongradeapplicationspleasecontactBaSFrepresentative.

•Besuretoallowformovementinthedeckbytheproperdesignanduseofexpansionandcontroljoints.

•Whenapplyingsealants,usebackingmaterialsaccordingtoindustrystandards.

•donotapplywhensubstratesareover110°F(32°C)orunder40°F(4°C).

•Whenusedindoors,provideadequateventilationwithaminimumofsixairchangesperhour.

•WhenadequateventilationforuseofMasterSealTraffic1500cannotbemaintained,refertoproductdatasheetforMasterSealTraffic2500(Formno.1017917).

•Becertainthatallaggregatenotproperlyencapsulatedisthoroughlyremoved.

•onsteeprampsinexcessof15%,contactyourlocalBaSFrepresentative.

•MasterSeal94116⁄30,roundedselectsilicasandisrecommended.

•Whenapplyingtometalpandecksordeckscontainingbetween-slabmembranes,contactTechnicalService.

•Selecttheproperamountofaggregatetopromoteslipresistance.

•Pre-stripetoleveloutrecessedsealantjoints(lessthan1"[25mm])foroptimalaestheticappearance.

•avoidapplicationofMasterSealTraffic1500wheninclementweatherispresentorimminent.

•donotapplyMasterSealTraffic1500todamp,wet,orcontaminatedsurfaces.

•MasterSealTraffic1500isnotsuitableforusewherechainedormetal-studdedtireswillbeused.

•Properapplicationistheresponsibilityoftheuser.FieldvisitsbyBaSFpersonnelareforthepurposeofmakingtechnicalrecommendationsonlyandnotforsupervisingorprovidingqualitycontrolonthejobsite.

LIMIteD WaRRantY nOtICe BaSFwarrantsthisproducttobefreefrommanufacturingdefectsandtomeetthetechnicalpropertiesonthecurrentTechnicaldataguide,ifusedasdirectedwithinshelflife.Satisfactoryresultsdependnotonlyonqualityproductsbutalsouponmanyfactorsbeyondourcontrol.BaSFMaKeSnooTherWarranTyorguaranTee,exPreSSorIMPLIed,InCLudIngWarranTIeSoFMerChanTaBILITyorFITneSSForaParTICuLarPurPoSeWIThreSPeCTToITSProduCTS.ThesoleandexclusiveremedyofPurchaserforanyclaimconcerningthisproduct,includingbutnotlimitedto,claimsallegingbreachofwarranty,negligence,strictliabilityorotherwise,isthereplacementofproductorrefundofthepurchaseprice,atthesoleoptionofBaSF.anyclaimsconcerningthisproductmustbereceivedinwritingwithinone(1)yearfromthedateofshipmentandanyclaimsnotpresentedwithinthatperiodarewaivedbyPurchaser.BaSFWILLnoTBereSPonSIBLeForanySPeCIaL,InCIdenTaL,ConSequenTIaL(InCLudIngLoSTProFITS)orPunITIvedaMageSoFanyKInd.

Purchasermustdeterminethesuitabilityoftheproductsfortheintendeduseandassumesallrisksandliabilitiesinconnectiontherewith.ThisinformationandallfurthertechnicaladvicearebasedonBaSF’spresentknowledgeandexperience.however,BaSFassumesnoliabilityforprovidingsuchinformationandadviceincludingtheextenttowhichsuchinformationandadvicemayrelatetoexistingthirdpartyintellectualpropertyrights,especiallypatentrights,norshallanylegalrelationshipbecreatedbyorarisefromtheprovisionofsuchinformationandadvice.BaSFreservestherighttomakeanychangesaccordingtotechnologicalprogressorfurtherdevelopments.ThePurchaseroftheProduct(s)musttesttheproduct(s)forsuitabilityfortheintendedapplicationandpurposebeforeproceedingwithafullapplicationoftheproduct(s).Performanceoftheproductdescribedhereinshouldbeverifiedbytestingandcarriedoutbyqualifiedexperts.

TechnicaldataguideMasterSeal® traffic 1500

Page 7: 7 Coatings - fdotwp1.dot.state.fl.us · 2 years when properly stored - MasterSeal 915: 1 year when properly stored Master Builders Solutions by BaSF Technical Data Guide. technical

Crack Detail (Dynamic)

Crack Detail (Static)—Sporadic Cracking

Crack Detail (Static)—alternate Option for Widespread Cracking

expansion Joint Detail (Greater than 1”)

expansion Joint Detail (Less than 1”)

Plywood application (Seam Detail)

MasterBuildersSolutionsbyBaSFwww.master-builders-solutions.basf.us

Page 8: 7 Coatings - fdotwp1.dot.state.fl.us · 2 years when properly stored - MasterSeal 915: 1 year when properly stored Master Builders Solutions by BaSF Technical Data Guide. technical

key-Way or termination Detail

Penetration Detail

Slab abutting Wall

Joint at Wall/Slab

Roof Drain

Wall Bearing on Slab

©2014BaSFCorporationFormno.1017893rev07/21/14

BaSf Corporation 889valleyParkdrive,Shakopee,Mn55379 Customer Service 1(800)433.9517Construction Systems www.master-builders-solutions.basf.us technical Service 1(800)243.6739

TechnicaldataguideMasterSeal® traffic 1500


Top Related