![Page 1: A. Beuret 11.05.2009 MedAustron Power Converters ~ 300 units required for Magnet Could be distributed into 5 family](https://reader036.vdocument.in/reader036/viewer/2022062408/56649f185503460f94c2f5c8/html5/thumbnails/1.jpg)
A. Beuret 11.05.2009
MedAustron Power Converters
• ~ 300 units required for • Magnet
Could be distributed into 5 family
![Page 2: A. Beuret 11.05.2009 MedAustron Power Converters ~ 300 units required for Magnet Could be distributed into 5 family](https://reader036.vdocument.in/reader036/viewer/2022062408/56649f185503460f94c2f5c8/html5/thumbnails/2.jpg)
A. Beuret 11.05.2009
Power Converter Families
• DC commercial (of the shelf ) Qty
– 1 quadrant 10V; 30A 40– 1 quadrant 15V; 300A 36
Control via RS 422
need(probably) adaptation to remote control via external chassis
![Page 3: A. Beuret 11.05.2009 MedAustron Power Converters ~ 300 units required for Magnet Could be distributed into 5 family](https://reader036.vdocument.in/reader036/viewer/2022062408/56649f185503460f94c2f5c8/html5/thumbnails/3.jpg)
A. Beuret 11.05.2009
Power Converter Families
Qty
• 4 Quadrant 50A; 30V to build on request 30
control to be integrated in the PC
![Page 4: A. Beuret 11.05.2009 MedAustron Power Converters ~ 300 units required for Magnet Could be distributed into 5 family](https://reader036.vdocument.in/reader036/viewer/2022062408/56649f185503460f94c2f5c8/html5/thumbnails/4.jpg)
A. Beuret 11.05.2009
Power Converter Families
Qty
4 Quadrant 150A; 40V 90
4 Quadrant 650A; 60V 12
4 Quadrant 350A; 70V 110
dedicated electronics chassis with space to house remote control
![Page 5: A. Beuret 11.05.2009 MedAustron Power Converters ~ 300 units required for Magnet Could be distributed into 5 family](https://reader036.vdocument.in/reader036/viewer/2022062408/56649f185503460f94c2f5c8/html5/thumbnails/5.jpg)
Qty
4 Quadrant 350A; 125V10
4 Quadrant 700A; 250V12
4 Quadrant 3000A; 180V11
4 Quadrant 1500A; 500V 1
4 Quadrant 4000A, 50V 2
A. Beuret 11.05.2009
Power Converter Families
2 bridges in //
dedicated electronics chassis with space to house remote control
![Page 6: A. Beuret 11.05.2009 MedAustron Power Converters ~ 300 units required for Magnet Could be distributed into 5 family](https://reader036.vdocument.in/reader036/viewer/2022062408/56649f185503460f94c2f5c8/html5/thumbnails/6.jpg)
A. Beuret 11.05.2009
Power Converter FamiliesQty
4 Quadrant 2300A; 600V 2
4 Quadrant 3000A; 1400V 1
20 kV
Active Front End
20 kV
Active Front End
![Page 7: A. Beuret 11.05.2009 MedAustron Power Converters ~ 300 units required for Magnet Could be distributed into 5 family](https://reader036.vdocument.in/reader036/viewer/2022062408/56649f185503460f94c2f5c8/html5/thumbnails/7.jpg)
Summary
• a) 76 commercial PC 1 Q for DC applications LEBT, MEBTcan be analogue driven or digitally via RS 422 (232, … )
• b) 30 4 Q 1.5 kW Function Generator + pc ControllerRemote control integrated in the converter
• c) 212 4 Q 6 – 40 kW Function Generator + pc Controller• d) 36 4Q 50 – 550 kW Function Generator + pc controller
Same electronics
Remote control integrated in the electronics crate
• e) 2 4Q 1.4 - 4.2 MW Function Generator + pc Controller
Specific electronics
Remote control integrated in the electronics crate
A. Beuret 11.05.2009
![Page 8: A. Beuret 11.05.2009 MedAustron Power Converters ~ 300 units required for Magnet Could be distributed into 5 family](https://reader036.vdocument.in/reader036/viewer/2022062408/56649f185503460f94c2f5c8/html5/thumbnails/8.jpg)
FGC and Converter functionalities
A. Beuret 11.05.2009