Transcript

Fill_Test_4inHydrostatic Test Pressurization and Trapped Air Content CalculatorComments:WPSS-015877 --Sunland/Air ProductsPipe OD:18in (actual)457.20mmPipe WT:0.406in10.31mmPipe Length:161779ft30.64miles49310.24m49.31kmTest_Press_Max:500psig34.47barg35.15348kg/cm^2Pack_Press:200psig13.79barg14.061392kg/cm^2Press Pump Rate:100gpm378.53L/minActual Volunme to Test Pressure:2542.5gal9624.20LPipe ID:17.19in436.58mmGal / Foot:12.0534gal/ft149.6924L/mFt^3 / Foot:1.61ft^3/ft0.15m^3/mPipeline Total Vol:1,949,992.90gal7381366.62LPipeline Total Vol:260,676.12ft^37381.53m^3Pipeline Total Vol:46,428.40bbl46428.40bbldaysGal / psi8.524213gal/psi467.98L/bar458.93326366Gal to Test Press:2557.26gal (at 70 degF)9680.09LdaysTime to Test Press:0.43hr0.02days0.43hr0.02(kg/cm^2)/minPressurization Rate:11.73psi/min703.88psi/hr0.81bar/min0.82tonnesEst Mill Scale:8188.71lb4.09tons3714.32kg3.71bbl%Trapped Air:-0.001%-0.001%Max Vol to Press:6462.36gal(from 0psig)24462.18LTrapped Air Acceptance Criterial is 0.2% MaximumRevision Date:May 31 2012TEE Pressure Pump w/4" Plungers = .817/gals per stroke x 3112 Strokes= 2542.5 galsCounted strokes from 200 psig to 500 psig