REMOTE ALARM INDICATORALD-RAI
PRODUCT DATA
REMOTE ALARM INDICATORALD-RAI
The Aquentis Remote Alarm Indicator has been designed for easy integration with the majority of alarm panels available today. By simply connecting to the clean volt-free normally open contacts which close on alarm the ALD-RAI warns when there is an alarm condition on the remote monitored module or panel.
General Information
The ALD-RAI has been designed to be a simple Remote Alarm indicator which can be located in both domestic and commercial environments.The unit is designed to harmonise with standard UK electrical accessories and can be fitted to a standard 35mm deep single gang surface, flush or plasterboard back box as well as Dado trunking frames.
The unit can be set in one of 3 modes:
?Visual only where the L.E.D. flashes with no sounder.?Audible only where the sounder pulses with no L.E.D.?Audible and visual where both the sounder and L.E.D. operate.
PRODUCT DATA
The Remote Alarm Indicator requires no attention in everyday use apart from pressing the Mute button once the unit is triggered. The L.E.D. will continue to flash after being muted until the alarm condition is removed when the ALD-RAI will automatically reset.
Simple Operation
Applications
The ALD-RAI can be used as a remote indicator for alarm and process conditions along with many other occurrences. It can be used to monitor any set of clean volt-free contacts such as Relays, switches, Float switches and Proximity contacts.
So dependent on the type of device monitored the ALD-RAI could be used to indicate conditions such as:
?Leak Detected.?Cable Fault?Water level High/Low?Smoke detected?Rain Detected
?Temperature High/Low ?Door/Window open/closed?Gas Detected?Assistance required?Equipment rack open
These are just a few of the many applications that the Remote Alarm Indicator could be used for if connected to the correct panel, module or sensor.
ALD-RAI Terminal layoutTypical installation of the ALD-RAI is carried out using a 4 core flexible cable which allows the power supply to the unit to be fed from the remote location. If a power supply is to be sited close to the Remote Alarm Indicator, only a 2 core cable is needed from the monitored equipment.
Suitable cables are:
4 Core CAEA-JC42 Core CAEA-JC2
Aquentis
REMOTE ALARM INDICATORALD-RAIPRODUCT DATA
The ALD-RAI is available in 2 variants:
ALD-RAI-W White plasticALD-LDM-SS Stainless Steel
Power Supply: 12/24Vdc
Interconnecting cable: 4 Core (Part # CAEA-JC4)
Trigger: Volt free clean contacts Close on alarm
Power consumption: 20mA @ 12Vdc40mA @ 24Vdc
Operating Conditions: -10 to +50?C,0% to 90% non-condensing
Status LED: Alarm (Blue flashing)
Sounder: Maximum 95dB (dependant on back box used)
Dimensions: HxWxD 85mm x 85mm x 33.8mm
Weight: White 72gStainless Steel
Product Information
Approvals
Electromagnetic compatibility (EMC)BS 5733 General requirements for electrical accessories
This document and all of it’s contents have been compiled with care, however due to continuous improvements in design and materials this information should only be treated as an example. The purchaser should satisfy themselves as to the suitability of the equipment to meet their intended application prior to placing an order and installing.Aquentis Limited makes no warranties as to the accuracy or completeness of the information, and disclaims any liability regarding its use.In no case will Aquentis be liable for any incidental, indirect, or consequential damages arising from the sale, resale, installation, use, or misuse of the product. Specifications are subject to change without notice. In addition, Aquentis Limited reserves the right to make changes without notification to processing or materials that do not affect compliance with any applicable specification.
This document and all of it’s contents have been compiled with care, however due to continuous improvements in design and materials this information should only be treated as an example. The purchaser should satisfy themselves as to the suitability of the equipment to meet their intended application prior to placing an order and installing.Aquentis Limited makes no warranties as to the accuracy or completeness of the information, and disclaims any liability regarding its use.In no case will Aquentis be liable for any incidental, indirect, or consequential damages arising from the sale, resale, installation, use, or misuse of the product. Specifications are subject to change without notice. In addition, Aquentis Limited reserves the right to make changes without notification to processing or materials that do not affect compliance with any applicable specification.
aquentis LimitedCritical Area Environmental Alarms
Tel: +44 (0)1277 810688 Fax: +44 (0)1277 563658 e-mail: [email protected] www.aquentis.com Reg England 4019857 Unit 2a, Farm Estate, Brentwood Road, Herongate, Brentwood, CM13 3LH UK
This document and all of it’s contents have been compiled with care, however due to continuous improvements in design and materials this information should only be treated as an example. The purchaser should satisfy themselves as to the suitability of the equipment to meet their intended application prior to placing an order and installing.Aquentis Limited makes no warranties as to the accuracy or completeness of the information, and disclaims any liability regarding its use.In no case will Aquentis be liable for any incidental, indirect, or consequential damages arising from the sale, resale, installation, use, or misuse of the product. Specifications are subject to change without notice. In addition, Aquentis Limited reserves the right to make changes without notification to processing or materials that do not affect compliance with any applicable specification.
RAI-D -0819S