All Product Catalogue AP-MDS-12
A Global Leader in System Solutions for Air Conditioning, Heating, Ventilating and Refrigeration.
Products manufactured in an ISO certified facility.This document contains the most current product information as of this printing.For the most up-to-date product information, please go to www.mcquayup.com.
©2012 McQuay International www.mcquayup.com
Manufacturing Plant
Cramlington
Cecchina
Kuala Lumpur
Jakarta
SuzhouWuhan
Shenzhen
Multi Digital ScrollSystem Features 4Application 12Outdoor Features 14Indoor Features 16Integrated Software 23Controller And Accessories 24Project References 25
SpecificationsR-22 Outdoor R-22 - 1R-22 Indoor R-22 - 3R-410A Outdoor R-410A - 1R-410A Indoor R-410A - 4
Minneapolis
Faribault
OwatonnaStauntan
Mexico City
Auburn
Africa• Ghana • Kenya • Madagascar • Mauritius • Morocco • Nigeria • South Africa • Sudan • Tanzania • Tunisia • Uganda
Americas• Argentina • Chile • Guadeloupe • Mexico • Paraguay • Puerto Rico • Uruguay
Asia• Cambodia • China • Hong Kong • Indonesia • Maldives • Myanmar• Nepal • Pakistan • Philippines • Singapore
Europe• Albania • Belgium • Croatia • Cyprus • Czech Republic • Greece• Hungary • Italy • Lithuania • Malta • Poland • Portugal• Russia • Serbia • Spain • Turkey • United Kingdom
Middle East• Azerbaijan • Bahrain • Iran • Jordan • Lebanon • Oman • Qatar • Syria • United Arab Emirates
Oceania• Fiji
5MDS 080/100/120/140/160/180BR
5MDS 050/060/070B/BR
25.0 - 47.0 28.0 - 53.0
5MDS 380/400/420BR
5MDS 200/220/240/260/280/300/320/340/360BR 53.0 - 94.0
102.0 - 111.0
59.0 - 106.0
113.0 - 124.0
5MDS 440/460/480/500BR 117.0 - 134.0 130.0 - 148.0
Model RangeCooling
Capacity (kW)Heating
Capacity (kW)
Model RangeCooling
Capacity (kW)Heating
Capacity (kW)
8.5 - 18.5
MDS 080/100/120/150B/BR
MDS 180/200/220/240/260/280/300/320B/BR
24.5 – 40.0
9.0 - 20.0
13.5 – 19.0 15.0 – 21.0
26.0 – 43.0
47.5 – 85.0 50.0 – 92.0
MDS 030/040/050/060/070A/AR
Split Type IndoorModel Range Cooling
Capacity (kW)Heating
Capacity (kW)R-410AR-22
MWMD-G2
MCKD-A
MCKD-C
MCMD-E
MCMD-D
MCCD-C
MDBD
HORIZONTALDISCHARGE
VERTICALDISCHARGE
VERTICALDISCHARGE
HORIZONTAL DISCHARGE
VERTICAL DISCHARGE
VERTICAL DISCHARGE
VERTICAL DISCHARGE
VERTICAL DISCHARGE
2.5 - 6.5
5.6 - 14.0
2.8 - 5.6
3.6 - 8.0
11.2 - 16.4
2.8 - 7.4
6.3 - 16.0
3.2 - 6.3
4.0 - 9.0
2.8 - 16.4 3.2 - 18.5
22.4 – 28.0 25.0 – 31.5
2 3
MDS R-410A Condensing Unit
MDS R-22 Condensing Unit
12.5 - 18.5
MORE ECONOMICAL OPERATIONWith higher IPLV, MDS is able to operate with lower power consumption.
4
NO CONVERSION LOSTComparing to the traditional inverter drive air-conditioner, MDS has eliminated the possibility of lost of energy during the conversion of power signal.
BETTER DEHUMIDIFYING PERFORMANCEThe continuously operating compressor in the MDS system provides better dehumidifying performance, and hence able to reduce the indoor RH to a more desired level. With lower RH in the interior, the growth of the bacteria and fungus are inhabited.
BETTER PART LOAD EFFICIENCYMost air-conditioning system operates in the 30%~70% region. Integrated with the digital scroll compressor technology, MDS is capable to modulate its supply capacity to meet most indoors requirement closely. This modulating capability enable the MDS system to offer higher IPLV (Integrated Part Load Value).
Utilising the digital scroll compressor technology, the McQuay Multi Digital ScrollSystem (MDS) is seen as the next generation products for high-efficiency air conditioning.
AC Converted FrequencyInverter
Compressor
Capacity Controller
TransformationConcumption = 0%
MotorConsumption
= 5-10%
DCAC DCTransformer
AC DCFrequency Conversion
T rad i t i ona l I n ve r t e r Sys tem
DigitalCompressorAC PWM valve
Capacity Controller
TransformationComsumption = 0%
MDS Sys tem
5th
7th
11th
13th
17th
19th
0 1 2 3 4 5
MDS System EMC Standard Inverter System
EMC comparison during development stage
Temp.
Time1 2 3 4
Tr
Ts
The temperature fluctuation range of traditional air conditioning system
The temperature fluctuation range of MDS system
Tr = Room TemperatureTs = Set Temperature
5
MDS 100B System
100%
5%
FixedCompressorOperating
DigitalOperating
DigitalOperating
Loading Unloading
MDS100BR IPLV Testing
2
2.5
3
3.5
4
4.5
0 20 40 60 80 100
IPLV(C) = 3.56
IPLV(H) = 3.71
Capacity (%)
Cooling
Heating
COP (W/W)
IPLV Testing Condition:Cooling cycle: 27°C DB / 19°C WB indoorand 27°C DB outdoorHeating cycle:20°C DB / 15°C WB indoorand 7°C DB / 6°C WB outdoor
IMPROVED ELECTROMAGNETIC COMPATIBILITYUnlike variable speed compressors air conditioners, MDS runs at a constant speed throughout the operation, thus there is lower electromagnetic interference. This unique feature reduces the need for expensive electromagnetic suppression electronics required to ensure electromagnetic compatibility.
TIGHTER TEMPERATURE CONTROLThe ambient of the outdoor and indoor change frequently and this will affect the indoor cooling and heating load. With MDS system, using an improved control algorithm, the temperature is kept closer to the set temperature.
6 7
Comparing to conventional chilled water system, MDS required lesser equipment. Boilers, cooling tower are things in the past with MDS. Thus, MDS is a better solution for new projects or even retrofit purposes.
Conventional ChilledWater System
MDS System
PERFORMANCE CHOICESOLUTIONS
Temperature °C
43°CDB
0°CDB
16°CWB
-15°CWDB
50
40
30
20
10
0
-10
-20
Cooling Cycle Heating Cycle
WIDER OPERATING RANGEMDS system undergo rigorous test to ensure that the system can operate within -15ºC to 43ºC.
INTELLIGENT CAPACITY MODULATIONThe MDS system operates in a stepless capacity modulation ranging from 10~100%. The modulation will closely match the demand capacity whereby contributing higher IPLV.
t1 t2Time
InitialTemperature
SettingTemperature
Traditional Air ConditioningMDS System
RAPID COOLING AND HEATING CAPABILITYThe improved heat-exchanger combining with the better efficiency compressor promotes rapid exchange between refrigerant and air, ensuring set temperature to be achieved faster compared to traditional air-conditioning system.
Height15m
PipingLength150m
Height50m
LONG PIPING DESIGN FOR FLEXIBILITYPiping length between outdoor and indoor unit can be extended up to 150 meters. The height between outdoor unit and indoor unit can be extended up to 50 meters. The height difference between indoor units can be as high as 15 meters. This greatly reduces constraint and offers more flexibility in system design.
The refnet joint is provided by the factory in accordance with different indoor units, which will reduce the work force at site.
Only a common 2-core, screen cable wire is required to enable communication between outdoor and indoors.
EASIER INSTALLATIONIn-house designed piping joints and wiring connection make it possible to install MDS system faster and easier.
BETTER PLACE UTILISATIONMDS uses the single outdoor multiple indoors combination. This concept has greatly reduced outdoor units and enhances flexibility during installation.
VARIETY OF INDOORSThe MDS indoors come with a variety of design and capacity which can be selected to suit most air conditioning needs.
8 9
ADAPTS EASIER TO ANY FLOOR PLANThe wide indoor models can meet the needs of building size and interior design easier. Incorporate with the flexible piping design, the MDS system is suitable for most type of floor layout and various applications.
ALARM AND DIAGNOSIS SYSTEMThe MDS system is built in with an alarm system, alerting owners or users for abnormal operation.A user-friendly diagnosis system helps to identify the problems, ensuring continuous operation of the MDS system.
AUTOAUTO
10 11
AUTO-RANDOM RESTARTAfter power failure, the MDS system will automatically restart operation base on the last state memory. Setting of the unit will not be lost, thus eliminating the needs for re-programming.
CENTRAL CONTROL SYSTEMThe MDS Smart Commander is designed with user-friendly interface, enable simple monitoring and control of the system via a computer.
MDS-B series is capable to connect up to 38 units of indoors. Total indoor units capacity can range from 50% to 120% of the outdoor capacity.
LARGE CAPACITY
With all these advantages, it is very clear that MDS is a better solution for centralised air-conditioning system. What would be the consideration factor to select MDS? Here are some of the main consideration factors and examples.
HospitalConsideration:• Places that require low or no EMC interference • Heat load of the same air-conditioned area varies.• Various type of indoor unit with separate temperature requirement • Centralized Control
OfficesConsideration:• Heat load of the same air-conditioned area varies.• Various type of indoor unit with separate temperature requirement • Location for outdoor is limited• Centralized Control
Department Store / RestaurantConsideration:• Heat load of the same air-conditioned area varies.• Various type of indoor unit with separate temperature requirement • Centralized Control
12 13
House / Apartment / CondominiumConsideration:• Location for outdoor is limited.• Various type of indoor unit with separate temperature requirement.• Heat load of the same air-conditioned area varies
Exhibition / Concert HallConsideration:• Heat load of the same air-conditioned area varies.• Various type of indoor unit with separate temperature requirement • Centralized Control
Factor 1Location for outdooris limited. MDS can be used due to the ability to couple multiple indoors with only 1 outdoor. Better space utilization.
Factor 2Various type of indoor unit with separate temperature requirementMDS system can be couple with various type of indoors. Each indoor can be design to supply to a specific area only and the temperature setting is base on individual indoor setting.
Factor 3Heat load of the same air-conditioned area variesMDS is able to match the indoor load requirement with its part loading capability.
Factor 5Places that require low or no EMC interferenceThe MDS modulation is control by mechanical parts. No change in power supply (frequency or current), thus lower electromagnetic interference.
Factor 4Centralized ControlMDS outdoors and indoors can be linked together and control using the MDS Smart Commander. The software can also perform scheduling of the indoor units base on the operating duration.
RELIABLE TECHNOLOGYMDS system adopts the advantaged capacity modulation technology to reduce the control devices, which reduce the malfunction odds mostly.
• MDS system has better oil return performance even at low capacities, which will make sure that all of the movable parts of the compressor can be lubricated and cooled down.
• It reduces the start/stop times, which will reduce the attack to the electricity supply net.
• The PWM (Pulse Width Modulation) valve has the longevity of 40 million times.
• The design is simple and there is no requirement for bypass valve.
SMALL FOOTPRINTThe outdoor unit of MDS system is designed as package, the structure occupies less space and is easier to move.
The brain of the MDS system is the compressor which is incorporated in the outdoor condensing unit.With this technology, the outdoor is constructed in a uniform and solid design and focusing on smaller footprint to provide better space utilisation.
UNIFORM DESIGNThe outdoor units can be located on the rooftop. The uniform outlook and dimension allows side by side installation.
QUIET OPERATIONThe condensing unit utilises an advanced spiral fan blades. The smooth material and fan blade design help to reduce the turbulent flow and thus reduce the air flow noise.
14 15
CKCeiling CassetteA Series & C SeriesMCKD 010/015/020 CMCKD 020/025/030/040/050 AM5CKD 010/015/020 CM5CKD 020/025/030/040/050 ACooling 9,600 Btu/h – 47,800 Btu/h 2.8 kW – 14.0 kWHeating 10,900 Btu/h – 54,600 Btu/h 3.2 kW – 16.0 kW
STYLISH AND SLIM PANELThe slim panel can be blended easily into most interior decoration and design.
700mm
CEILING AND FLOOR INSTALLATION OPTIONThe MCMD is designed with the option to install either below the ceiling or mounted at low wall position to suit most interior design requirement.
4 WAY AIR DISCHARGE AND AIR SWINGIt comes with 4 way air discharge and air swing function to ensure better air distribution and circulation in the room.
CCCeiling ConvertibleE SeriesMCMD 020/025/028 EM5CMD 015/020/025/028 ECooling 12,300 Btu/h - 27,300 Btu/h 3.6 kW - 8.0 kWHeating 13,600 Btu/h - 30,700 Btu/h 4.0 kW - 9.0 kW
700mm
BUILT-IN HIGH HEAD DRAIN PUMPThe unit comes with a built-in high head drain pump 700mm head. A safety float is incorporated in the drain pump to monitor its water level.
FLEXIBLE INSTALLATION The unit is designed to work with high pressure head drain pump (optional). Thus offering flexibility for installation on condensate drain pipe. The drain pump comes with a high head and is incorporate with the float switch as safety protection.
18 19
BETTER SERVICEABILITYThe washable filter can be easily access by just pulling down the intake grill. During servicing or repairing, only the bottom panel need to be remove in order to access. • Fan Motor• Blower• Wiring Connection• Control Box• Piping Connection
Wall bracket supplied as optional item
GS01
GS01
CMCeiling ConvertibleD SeriesMCMD 040/050 DMCMD 062 CM5CMD 040/050 DM5CMD 062 CCooling 38,200 Btu/h – 56,000 Btu/h 11.2 kW – 16.4 kWHeating 42,700 Btu/h – 63,100 Btu/h 12.5 kW – 18.5 kW
Ceiling ConcealedC SeriesMCCD 010/015/020/025/030/040/050/060 CM5CCD 010/015/020/025/028/030/038/040/050/060 CCooling 9,600 Btu/h – 56,000 Btu/h 2.8 kW – 16.4 kWHeating 10,900 Btu/h – 63,100 Btu/h 3.2 kW – 18.5 kW
CC
TWO WAY AIR DISCHARGE
Equipped with two way air discharge, at front and bottom discharge; to provide better air distribution, for both cooling and heating effect.
AUTOMATIC AIR SWING *
The swing mode enables the air flow to be evenly distributed into the room from the front discharge area.* Applicable for M(5)CMD 040/050D only.
CEILING AND FLOOR INSTALLING OPTION *
The unit is designed with possibility to be installed under the ceiling or sitting on the floor to suit most interior design requirements.* Applicable for M(5)CMD 040/050D only.
DOUBLE PROTECTION DRAINAGE SYSTEM
The primary drain pan is designed with higher thermal insulation material and moulded in gradient for better condensate water drainage. The extra secondary drain pan “built in” to the standard unit offers extra protection against possible water leaking problems.
Primary Drain PanPolysterene (Ps) With Height Impact Polystyrene (Hips) Cover
Secondary Drain Pan With Insulation
FLEXIBILITY IN SYSTEM DESIGN
The unit offers fan motor that can operate up to 4 speeds, thus provide choices of external static pressure for designing ducting system.
20 21
GS01 MC301
ICE CREAM
ICE CREAM
COMPLETE MODELTo ease installation, this model has the Electronic Expansion Valve (EXV) built into the unit. User do not need to worry about the noise from the EXV as it is properly insulated.
DBDucted BlowerMDBD 080 / 100Cooling 76,400 Btu/h – 95,500 Btu/h 22.4 kW – 28.0 kWHeating 85,300 Btu/h – 107,500 Btu/h 25.0 kW – 31.5 kW
MDS SMART COMMANDERFor central monitoring and control purposes, the MDS offers a real time system. This software is the system to human interface, allowing users or owners to monitor and to control the MDS system. With this software, user or owners is able to ;• Monitor & control any MDS indoor & outdoor unit • Alarming alert• Zoning & grouping capabilities • Scheduling option
BETTER AIR DISTRIBUTION FOR COMFORTABLE LIVINGThe conditioned air can be effectively distributed to the room through ducting.
EXTENDED INDOOR MODELThe ducted blower is designed to cater higher indoor capacity required. Combining ceiling concealed and ducted blower, the MDS system is able to fulfill ducted application with capacity range from 2.8kW to 28.0kW
As a system provider, McQuay MDS system is equipped together with a collection of customized software to provide system design & selection and individual units control & monitoring.
22 23
SELECTION SOFTWAREThis software is incorporated with data on indoor models. This allow the designers to choose the appropriate indoors model to suit they needs. Besides that, this software will determine the required quantity of refnet joints, pipes and other accessories base on the design. With this software, most designs can be completed with just a few simple clicks.
MC301
CENTRAL CONTROLLER MC303Optional Item. To provide group or individual control to indoors (Up to 32 indoors). Basic control such as ON/OFF, mode setting, temperature setting and others.
Standard Controller
Optional Controllerand Accessories
PC CONTROLMDS Smart Commander act as the system to human interface. A communication gateway is inclusive for the wiring connection.
WIRED CONTROLLER MC301Standard wired controller for MCCD-C. Basic control such as ON/OFF, mode setting, temperature setting and others.
WIRELESS GS01Standard wireless handset for wall mounted, ceiling cassette and ceiling convertible. Basic control such as ON/OFF, mode setting, temperature setting and others.
Commercial SectorCountry : ThailandIndoor Type : Ceiling Concealed
Commercial SectorCountry : ChinaIndoor Type : Ceiling Concealed Ceiling Convertible
Residential SectorCountry : QatarIndoor Type : Wall Mounted
Residential SectorCountry : IndonesiaIndoor Type : Ceiling Concealed
Commercial SectorCountry : SingaporeIndoor Type : Ceiling Concealed Ceiling Convertible Ceiling Cassette
Residential SectorCountry : SyriaIndoor Type : Ceiling Concealed
MDS systems has proven to be reliable and a system of choice.Many projects, whether government or privately own premises had chosen MDS as their comfort provider:
24 25
REFNET & DISTRIBUTORS JOINTPiping joint design for the MDS system. A total of 6 types of refnet joint is available for different piping combination.
R-221
R-222
R-22 Outdoor SpecificationsMDS-A
MDS 030AR MDS 040AR MDS 050AR MDS 060AR MDS 070AR
Btu/h 29,002 34,120 42,650 49,474 61,400
W 8,500 10,000 13,000 <12,500> 14,500 <14,500> 18,500
Btu/h 30,708 39,238 46,062 56,298 68,200
W 9,000 11,500 14,000 <13,500> 16,500 <16,500> 20,000
COOLING W 3,000 3,500 4,400 <4,300> 5,000 <5,000> 5,800
HEATING W 2,500 3,400 4,200 <3,900> 4,200 <4,200> 5,000
MDS 030A MDS 040A MDS 050A MDS 060A MDS 070A
Btu/h 29,002 34,120 42,650 49,474 61,400
W 8,500 10,000 13,000 <12,500> 14,500 <14,500> 18,500
W 3,000 3,500 4,400 <4,300> 5,000 <5,000> 5,800
V/Ph/Hz 220-240 / 1 / 50 220-240 / 1 / 50 220-240 / 1 / 50<380-415 / 3 / 50>
220-240 / 1 / 50<380-415 / 3 / 50> 380-415/ 3/ 50
R-22 R-22 R-22 R-22 R-22
l/s / cfm 1056 / 2237 695 + 695 / 1470 + 1470 695 + 695 / 1470 + 1470 1055 + 1055 / 2230 + 2230 1111 + 1111 / 2354 + 2354
dB(A) 59 59 59 60 62
HEIGHT mm/in 900 / 35.4 1044 / 41.4 1044 / 41.4 1247 / 49.1 1349 / 53.1
WIDTH mm/in 840 / 33.1 1058 / 41.7 1058 / 41.7 1058 / 41.7 1058 / 41.7
DEPTH mm/in 408 / 16.1 430 / 16.9 430 / 16.9 430 / 16.9 430 / 16.9
kg/lb 82 / 181 112 / 247 117 / 258 123 / 271 135 / 298
kg/lb 85 / 187 115 / 254 120 / 265 130 / 287 145 / 320
TYPE (LIQUID/GAS) FLARE FLARE FLARE FLARE FLARE
LIQUID mm/in 9.5 / 3/8 9.5 / 3/8 9.5 / 3/8 9.5 / 3/8 9.5 / 3/8
GAS mm/in 15.9 / 5/8 19.1 / 3/4 19.1 / 3/4 19.1 / 3/4 22.2 / 7/8
HEATPUMPUNIT WEIGHT
NOMINAL TOTAL INPUTPOWER - 1Ø <3Ø>
UNIT DIMENSION
POWER SOURCE - 1Ø <3Ø>
REFRIGERANT TYPE
OU
TD
OO
R U
NIT
SOUND PRESSURE LEVEL
PIPECONNECTION SIZE
COOLING ONLY
MODEL OUTDOOR UNIT
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
AIR FLOW
MODEL OUTDOOR UNIT
NOMINAL COOLING CAPACITY
NOMINAL TOTAL INPUT POWER - 1Ø <3Ø>
NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 (NON DUCTED PRODUCT) OR ISO13253 (DUCTED PRODUCT).3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVELS ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT THE MACHINE AND 1.42m ABOVE THE MACHINE BASE.5) THE VALUE OF REFRIGERANT CHARGE IS THE REFRIGERANT CHARGED IN THE OUTDOOR UNIT BEFORE LEAVING FACTORY. THIS CHARGE DOES NOT INCLUDE THE AMOUNT NEEDED FOR EXTENDED PIPING.
MDS-B
MDS 080BR MDS 100BR MDS 120BR MDS 150BR
Btu/h 83,594 95,536 110,890 136,480
W 24,500 28,000 32,500 40,000
Btu/h 88,712 102,360 116,008 146,716
W 26,000 30,000 34,000 43,000
COOLING W 7,500 8,500 9,800 12,900
HEATING W 7,200 8,300 9,000 11,100
MDS 080B MDS 100B MDS 120B MDS 150B
Btu/h 83,594 95,536 110,890 136,480
W 24,500 28,000 32,500 40,000
W 7,500 8,500 9,800 12,900
V/Ph/Hz
R-22 R-22 R-22 R-22
HI-FAN l/s / cfm 3194 / 6768 3194 / 6768 3472 / 7357 3750 / 7945
LOW-FAN l/s / cfm 1528 / 3237 1528 / 3237 2083 / 4414 2222 / 4708
dB(A) 62 64 66 67
HEIGHT mm/in 1840 / 72.4 1840 / 72.4 1840 / 72.4 1840 / 72.4
WIDTH mm/in 990 / 39.0 990 / 39.0 990 / 39.0 1290 / 50.8
DEPTH mm/in 840 / 33.1 840 / 33.1 840 / 33.1 840 / 33.1
kg/lb 275 / 606 285 / 628 290 / 639 355 / 783
kg/lb 290 / 639 300 / 661 305 / 672 370 / 816
Flare / Brazed Flare / Brazed Flare / Brazed Flare / Brazed
LIQUID mm/in 12.7 / 1/2 12.7 / 1/2 15.9 / 5/8 15.9 / 5/8
GAS mm/in 28.6 / 1 1/8 28.6 / 1 1/8 28.6 / 1 1/8 34.9 / 1 3/8
NOMINAL TOTAL INPUT POWER
MODEL OUTDOOR UNIT
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
380-415 / 3 / 50
COOLING ONLY
OUTDOOR UNIT
NOMINAL COOLING CAPACITY
NOMINAL TOTAL INPUT POWER
OU
TD
OO
R U
NIT
HEATPUMPUNIT WEIGHT
MODEL
POWER SOURCE
PIPECONNECTION
TYPE (LIQUID/GAS)
SIZE
REFRIGERANT TYPE
AIR FLOW
SOUND PRESSURE LEVEL
UNIT DIMENSION
MDS-B
MDS 180BR MDS 200BR MDS 220BR MDS 240BR
Btu/h 162,070 170,600 187,660 221,780
W 47,500 50,000 55,000 65,000
Btu/h 170,600 180,836 197,896 232,016
W 50,000 53,000 58,000 68,000
COOLING W 14,100 15,200 16,700 19,800
HEATING W 13,200 14,700 16,200 18,500
MDS 180B MDS 200B MDS 220B MDS 240B
Btu/h 162,070 170,600 187,660 221,780
W 47,500 50,000 55,000 65,000
W 14,100 15,200 16,700 19,800
V/Ph/Hz
R-22 R-22 R-22 R-22
HI-FAN l/s / cfm 3194 + 3194 / 6768 + 6768 3194 + 3194 / 6768 + 6768 3194 + 3194 / 6768 + 6768 3472 + 3472 / 7357 + 7357
LOW-FAN l/s / cfm 1528 + 1528 / 3237 + 3237 1528 + 1528 / 3237 + 3237 1528 + 1528 / 3237 + 3237 2083 + 2083 / 4414 + 4414
dB(A) 66 66 66 68
HEIGHT mm/in 1840 / 72.4 1840 / 72.4 1840 / 72.4 1840 / 72.4
WIDTH mm/in 1990 / 78.3 1990 / 78.3 1990 / 78.3 1990 / 78.3
DEPTH mm/in 840 / 33.1 840 / 33.1 840 / 33.1 840 / 33.1
kg/lb 520 / 1146 560 / 1235 560 / 1235 570 / 1257
kg/lb 550 / 1213 590 / 1301 590 / 1301 600 / 1323
Flare / Brazed Flare / Brazed Flare / Brazed Flare / Brazed
LIQUID mm/in 15.9 / 5/8 15.9 / 5/8 19.1 / 3/4 19.1 / 3/4
GAS mm/in 34.9 / 1 3/8 34.9 / 1 3/8 38.1 / 1 1/2 38.1 / 1 1/2
380-415 / 3 / 50
TYPE (LIQUID/GAS)
SIZE
NOMINAL TOTAL INPUT POWER
UNIT DIMENSION
POWER SOURCE
REFRIGERANT TYPE
MODEL OUTDOOR UNIT
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
PIPE CONNECTION
AIR FLOW
COOLING ONLY
HEATPUMPOU
TD
OO
R U
NIT
SOUND PRESSURE LEVEL
UNIT WEIGHT
MODEL OUTDOOR UNIT
NOMINAL COOLING CAPACITY
NOMINAL TOTAL INPUT POWER
NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 (NON DUCTED PRODUCT) OR ISO13253 (DUCTED PRODUCT).3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVELS ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT THE MACHINE AND 1.42m ABOVE THE MACHINE BASE.5) THE VALUE OF REFRIGERANT CHARGE IS THE REFRIGERANT CHARGED IN THE OUTDOOR UNIT BEFORE LEAVING FACTORY. THIS CHARGE DOES NOT INCLUDE THE AMOUNT NEEDED FOR EXTENDED PIPING.
MDS-BMDS 260BR MDS 280BR MDS 300BR MDS 320B
MDS 120BRM + MDS 150BRS MDS 150BRM +MDS 130BRS MDS 150BRM + MDS 150BRS MDS 160BRM + MDS 160BRS
Btu/h 238,840 242,252 272,960 290,020
W 70,000 71,000 80,000 85,000
Btu/h 255,900 266,136 290,020 313,904
W 75,000 78,000 85,000 92,000
COOLING W 21,300 21,000 26,200 27,700
HEATING W 20,900 20,300 23,600 25,500
MDS 260B MDS 280B MDS 300B MDS 320B
MDS 120BM + MDS 150BS MDS 150BM + MDS 130BS MDS 150BM + MDS 150BS MDS 160BM + MDS 160BS
Btu/h 238,840 242,252 272,960 290,020
W 70,000 71,000 80,000 85,000
W 21,300 21,000 26,200 27,700
V/Ph/Hz
R-22 R-22 R-22 R-22
HI-FAN l/s / cfm 3472 + 3750 / 7357 + 7945 3750 + 3750 / 7945 + 7945 3750 + 3750 / 7945 + 7945 3750 + 3750 / 7945 + 7945
LOW-FAN l/s / cfm 2083 + 2222 / 4414 + 4708 2222 + 2222 / 4708 + 4708 2222 + 2222 / 4708 + 4708 2222 + 2222 / 4708 + 4708
dB(A) 68 69 69 69
HEIGHT mm/in 1840/72.4 1840/72.4 1840/72.4 1840/72.4
WIDTH mm/in 2280/89.8 2580/101.6 2580/101.6 2580/101.6
DEPTH mm/in 840/33.1 840/33.1 840/33.1 840/33.1
kg/lb 645 / 1422 710 / 1565 710 / 1565 720 / 1587
kg/lb 675 / 1488 740 / 1631 740 / 1631 750 / 1653
Flare/Brazed Flare/Brazed Flare/Brazed Flare/Brazed
LIQUID mm/in 19.1 / 3/4 19.1 / 3/4 19.1 / 3/4 19.1 / 3/4
GAS mm/in 41.3 / 1 5/8 41.3 / 1 5/8 41.3 / 1 5/8 41.3 / 1 5/8
COOLING ONLY
HEATPUMP
380-415 / 3 / 50POWER SOURCE
REFRIGERANT TYPE
OU
TD
OO
R U
NIT
SOUND PRESSURE LEVEL
UNIT DIMENSION
PIPE CONNECTION
TYPE (LIQUID/GAS)
SIZE
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
NOMINAL TOTAL INPUT POWER
MODELOUTDOOR UNIT
MASTER UNIT+SLAVE UNIT
AIR FLOW
UNIT WEIGHT
MODELMASTER UNIT+SLAVE UNIT
OUTDOOR UNIT
NOMINAL COOLING CAPACITY
NOMINAL TOTAL INPUT POWER
R-22 Indoor Specifications
R-223
R-224
MWMD-G
HIGH
MEDIUM
LOW
HEIGHT
WIDTH
DEPTH
LIQUID
GAS
NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 (NON DUCTED PRODUCT) OR ISO13253 (DUCTED PRODUCT).3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 0.8m BELOW THE UNIT.5) ALL INDOOR MODELS CAN BE USED FOR COOLING ONLY OR HEATPUMP APPLICATION.
SOUND PRESSURE LEVEL (H/M/L)
UNIT DIMENSION
IND
OO
R U
NIT
UNIT WEIGHT
AIR FLOW
MODEL INDOOR UNIT
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
POWER SOURCE
REFRIGERANT TYPE
REFRIGERANT CONTROL (EXPANSION DEVICE)
PIPE CONNECTION
TYPE
SIZE
MWMD 009G2 MWMD 010G2 MWMD 015G2 MWMD 020G2 MWMD 025G2
8500 9600 12300 19100 22200
2500 2800 3600 5600 6500
9600 10900 13600 21500 25200
2800 3200 4000 6300 7400
130 / 275 142 / 300 163 / 345 231 / 490 397 / 630
106 / 225 118 / 250 135 / 285 193 / 410 231 / 490
83 / 175 94 / 200 104 / 220 160 / 340 208 / 440
40 / 35 / 29 39 / 34 / 28 42 / 36 / 29 43 / 40 / 35 49 / 44 / 42
304 / 12.0 304 / 12.0
799 / 31.5 1062 / 41.8 1062 / 41.8
222 / 8.7 222 / 8.7
10 / 22.0 16 / 35.3 16 / 35.3
9.5 / 3/8
12.7 / 1/2
899 / 35.4
12 / 26.5
220 - 240 / 1 / 50
R-22
EXV
260 / 10.2
198 / 7.8
FLARE VALVE
6.4 / 1/4
9.5 / 3/8 15.9 / 5/8
Btu/h
W
Btu/h
W
V/Ph/Hz
l/s / cfm
l/s / cfm
l/s / cfm
dBA
mm/in
mm/in
mm/in
kg/lb
mm/in
mm/in
MCKD-C
PIPE CONNECTIONSIZE
AIR FLOW
REFRIGERANT TYPE
SOUND PRESSURE LEVEL (H/M/L)
UNIT WEIGHT (UNIT + PANEL)
UNIT DIMENSION ( ) - WITH PANEL
MODEL INDOOR UNIT
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
POWER SOURCE
IND
OO
R U
NIT
NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 (NON DUCTED PRODUCT) OR ISO13253 (DUCTED PRODUCT).3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVELS ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.4m BELOW FASCIA.5) ALL INDOOR MODELS CAN BE USED FOR COOLING ONLY OR HEATPUMP APPLICATION.
MCKD 020C
19100
5600
21500
6300
212 / 450
194 / 410
160 / 340
44 / 41 / 37
23 + 2 / 50.7 + 4.4
15.9 / 5/8
MCKD 015C
12300
3600
13600
4000
194 / 410
170 / 360
156 / 330
41 / 38 / 34
23 + 2 / 50.7 + 4.4
12.7 / 1/2
FLARE VALVE
6.4 / 1/4
570 (640) / 22.4 (25.2)
570 (640) / 22.4 (25.2)
250 (295) / 9.8 (11.6)
R-22
REFRIGERANT CONTROL (EXPANSION DEVICE) EXV
220 - 240 / 1 / 50
MCKD 010C
9600
2800
10900
3200
194 / 410
170 / 360
156 / 330
41 / 38 / 35
22 + 2 / 48.5 + 4.4
9.5 / 3/8
Btu/h
W
Btu/h
W
V/Ph/Hz
l/s / CFM
l/s / CFM
l/s / CFM
dBA
mm/in
mm/in
mm/in
kg/lb
mm/in
mm/in
HIGH
MEDIUM
LOW
HEIGHT
WIDTH
DEPTH
LIQUID
GAS
TYPE
MCMD-E
NOTE:1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 (NON DUCTED PRODUCT) OR ISO13253 (DUCTED PRODUCT).3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 0.8m BELOW THE UNIT.5) ALL INDOOR MODELS CAN BE USED FOR COOLING ONLY OR HEATPUMP APPLICATION.
POWER SOURCE
REFRIGERANT TYPE
REFRIGERANT CONTROL (EXPANSION DEVICE)
SOUND PRESSURE LEVEL (H/M/L)
AIR FLOW
UNIT WEIGHT
UNIT DIMENSION
PIPE CONNECTION 9.5 / 3/8
MODEL INDOOR UNIT
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
IND
OO
R U
NIT
MCMD 028E
27300
8000
30700
9000
302 / 640
264 / 560
217 / 460
51 / 48 / 47
28 / 61.7
MCMD 025E
22200
6500
25200
7400
274 / 580
250 / 530
231 / 490
50 / 47 / 46
220 - 240 / 1 / 50
R-22
EXV
FLARE VALVE
15.9 / 5/8
218 / 8.6
1080 / 42.5
630 / 24.8
27 / 59.5
MCMD 020E
19100
5600
21500
6300
245 / 520
217 / 460
192 / 406
48 / 46 / 43
6.4 / 1/4
Btu/h
W
Btu/h
W
V/Ph/Hz
l/s / CFM
l/s / CFM
l/s / CFM
dBA
mm/in
mm/in
mm/in
kg/lb
mm/in
mm/in
HIGH
MEDIUM
LOW
HEIGHT
WIDTH
DEPTH
TYPE
SIZELIQUID
GAS
MCKD-A
NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151(NON DUCTED PRODUCT) OR ISO13253 (DUCTED PRODUCT).3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4a) M5CKD020-025A: SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.4m BELOW FASCIA.4b) M5CKD030-040A: SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.5m BELOW FASCIA.5) ALL INDOOR MODELS CAN BE USED FOR COOLING ONLY OR HEATPUMP APPLICATION.
PIPE CONNECTION
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
SOUND PRESSURE LEVEL (H/M/L)
AIR FLOW
UNIT DIMENSION( ) - WITH PANELINDOOR UNIT
UNIT WEIGHT (UNIT + PANEL)
MODEL INDOOR UNIT
POWER SOURCE
REFRIGERANT TYPE
REFRIGERANT CONTROL (EXPANSION DEVICE)
IND
OO
R U
NIT
MCKD 020A MCKD 025A MCKD 030A MCKD 040A MCKD 050A
19100 22200 30700 38200 47800
5600 6500 9000 11200 14000
21500 25200 34100 42700 54600
6300 7400 10000 12500 16000
220 - 240 / 1 / 50
349 / 740 368 / 780 415 / 880 467 / 990 491 / 1040
297 / 630 311 / 660 349 / 740 406 / 860 448 / 950
283 / 600 283 / 600 321 / 680 359 / 760 411 / 870
42 / 39 / 37 45 / 42 / 40 49 / 45 / 43 51 / 48 / 46 53 / 52 / 50
31 + 4 / 68.3 + 8.8 32 + 4 / 70.5 + 8.8 35 + 4 / 77.2 + 8.8 38 + 4 / 83.8 + 8.8 40 + 4 / 88.2 + 8.8
6.4 / 1/4
FLARE VALVE
9.5 / 3/8
15.9 / 5/8 19.1 / 3/4
820 (930) / 32.2 (36.6)
R-22
EXV
335 (378) / 13.2 (14.9)
820 (930) / 32.2 (36.6)
Btu/h
W
Btu/h
W
V/Ph/Hz
l/s / CFM
l/s / CFM
l/s / CFM
dBA
mm/in
mm/in
mm/in
kg/lb
mm/in
mm/in
TYPE
SIZE
HEIGHT
WIDTH
HIGH
DEPTH
MEDIUM
LOW
LIQUID
GAS
R-225
R-226
LIQUID
GAS
NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 (NON DUCTED PRODUCT) OR ISO13253 (DUCTED PRODUCT).3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.5) ALL INDOOR MODELS CAN BE USED FOR COOLING ONLY OR HEATPUMP APPLICATION.
MODEL INDOOR UNIT
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
WIDTH
DEPTH
UNIT WEIGHT
UNIT DIMENSION
HEIGHT
HIGH
SOUND PRESSURE LEVEL (H/M/L)
AIR FLOW
LOW
MEDIUM
IND
OO
R U
NIT
POWER SOURCE
REFRIGERANT TYPE
REFRIGERANT CONTROL (EXPANSION DEVICE)
PIPE CONNECTION
TYPE
SIZE
MCMD-D/C
MCMD 040D MCMD 050D MCMD 062C
Btu/h 38200 47800 56000
W 11200 14000 16400
Btu/h 42700 54600 63100
W 12500 16000 18500
V/Ph/Hz
l/s / CFM 477 / 1010 491 / 1040 732 / 1550
l/s / CFM 420 / 890 448 / 950 623 / 1320
l/s / CFM 368 / 780 387 / 820 472 / 1000
dBA 54 / 53 / 52 54 / 53 / 52 56 / 53 / 46
mm/in 285 / 11.2
mm/in 1903 / 74.9
mm/in 680 / 26.8
kg/lb 85 / 187.4
mm/in 12.7 / 1/2
mm/in
70 / 154.3
1714 / 67.4
670 / 26.3
249 / 9.8
EXV
220 - 240 / 1 / 50
R-22
9.5 / 3/8
FLARE VALVE
19.1 / 3/4
NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 (NON DUCTED PRODUCT) OR ISO13253 (DUCTED PRODUCT).3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO GB/D17758 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.4M BELOW THE UNIT (FREE RETURN AND THE DISCHARGE AIR WAS DUCTED TO ADJACENT ROOM).5) ALL INDOOR MODELS CAN BE USED FOR COOLING ONLY OR HEATPUMP APPLICATION.
MCCD-C
EXTERNAL STATIC PRESSURE (H/M/L)
LIQUIDGAS
MODEL
AIR FLOW(LOW STATIC)
AIR FLOW
CONTROL
LOW
DEPTH
LOW
UNIT DIMENSION
HEIGHT
INDOOR UNIT
REFRIGERANT TYPE
HIGH
MEDIUM
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
POWER SOURCE
WIDTH
SOUND PRESSURE LEVEL(LOW STATIC, H/M/L)
WEIGHT
PIPE CONNECTIONTYPE
SIZE15.9 / 5/8
EXTERNAL STATIC PRESSURE(LOW STATIC, H/M/L)
IND
OO
R U
NIT
MCCD 025C
22200
6500
25200
7400
270 / 580
360 / 770
340 / 720
270 / 580
49 / 43 / 30 (0.20 / 0.17 / 0.12)
40 / 39 / 35
261 / 10.3
1200 / 47.2
411 / 16.2
25 / 55.1
9.5 / 3/8
MCCD 020C
19100
5600
21500
6300
300 / 640
310 / 650
300 / 640
270 / 570
49 / 45 / 41 (0.20 / 0.18 / 0.17)
20 / 18 / 11 (0.08 / 0.07 / 0.04)20 / 19 / 15 (0.08 / 0.07 / 0.06)
38 / 37 / 35
261 / 10.3
1065 / 41.9
411 / 16.2
22 / 48.5
220 - 240 / 1 / 50
R-22
REFRIGERANT CONTROL (EXPANSION DEVICE) EXV
FLARE VALVE
MCCD 015C
12300
3600
13600
4000
190 / 400
250 / 540
240 / 500
180 / 380
36 / 33 / 28
21 / 46.3
12.7 / 1/2
261 / 10.3
905 / 35.6
411 / 16.2
6.4 / 1/4
MCCD 010C
9600
2800
10900
3200
120 / 260
140 / 300
130 / 275
110 / 225
49 / 44 / 36 (0.20 / 0.18 / 0.15) 49 / 42 / 28 (0.20 / 0.17 / 0.11)
10 / 8 / 5 (0.04 / 0.03 / 0.02) 10 / 8 / 5 (0.04 / 0.03 / 0.02)
33 / 30 / 25
17 / 37.5
9.5 / 3/8
261 / 10.3
765 / 30.1
411 / 16.2
Btu/h
W
Btu/h
W
V/Ph/Hz
l/s / CFM
l/s / CFM
l/s / CFM
HIGH
MEDIUM
340 / 730
310 / 660
330 / 700
320 / 675
240 / 510
230 / 490
140 / 300
130 / 285
l/s / CFM
l/s / CFM
OPERATION WIRED CONTROL
AIR DISCHARGE DUCTED
l/s / CFM
Pa (in.wg.)
Pa (in.wg.)
dBA
SOUND PRESSURE LEVEL (H/M/L) 41 / 40 / 3642 / 41 / 4040 / 38 / 3336 / 35 / 33dBA
mm/in
mm/in
mm/in
kg/lb
mm/inmm/in
EXTERNAL STATIC PRESSURE (H/M/L)
LIQUIDGAS
LOW
CONTROL
UNIT DIMENSION
HEIGHT
INDOOR UNIT
REFRIGERANT TYPE / CONTROL
HIGH
MEDIUM
AIR DISCHARGE
OPERATION
MODEL
AIR FLOW(LOW STATIC)
SUPER HIGH
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
POWER SOURCE
WIDTH
SOUND PRESSURE LEVEL (H/M/L)
WEIGHT
PIPE CONNECTIONTYPE
SIZE
DEPTH
MCCD-C
IND
OO
R U
NIT
MCCD 060C
56000
16400
63100
18500
802 / 1700
765 / 1620
717 / 1520
693 / 1470
176/157/137/98(0.71/0.63/0.55/0.39)
55 / 53 / 50 / 47
378 / 14.9
1499 / 59.0
541 / 21.3
62 / 136.7
12.7 / 1/2
MCCD 050C
47800
14000
54600
16000
713 / 1510
628 / 1330
618 / 1310
599 / 1270
176/157/137/108(0.71/0.63/0.55/0.43)
53 / 52 / 50 / 47
378 / 14.9
1299 / 51.1
541 / 21.3
54 / 119.1
19.1 / 3/4
FLARE VALVE
R-22 / EXV
DUCTED
WIRED CONTROL
220 - 240 / 1 / 50
MCCD 040C
38200
11200
42700
12500
562 / 1190
500 / 1060
472 / 1000
458 / 970
206/176/127/93(0.83/0.71/0.51/0.37)
69/49/29/20(0.28/0.20/0.12/0.08)78/59/39/20(0.31/0.24/0.16/0.08)49/39/29/20(0.20/0.16/0.12/0.08)
51 / 49 / 45 / 41
378 / 14.9
1045 / 41.1
541 / 21.3
42 / 92.6
9.5 / 3/8
MCCD 030C
30700
9000
34100
10000
444 / 940
415 / 880
373 / 790
349 / 740
206/167/127/88(0.83/0.67/0.51/0.35)
49/39/29/20(0.20/0.16/0.12/0.08)
49 / 46 / 42 / 38
378 / 14.9
929 / 36.6
541 / 21.3
39 / 86.0
15.9 / 5/8
Btu/h
W
Btu/h
W
V/Ph/Hz
l/s / CFM
l/s / CFM
l/s / CFM
l/s / CFM
LOW
HIGH
MEDIUMAIR FLOW
SUPER HIGH 779 / 1650
722 / 1530
675 / 1430
609 / 1290
750 / 1590
651 / 1380
604 / 1280
571 / 1210
519 / 1100
500 / 1060
467 / 990
425 / 900
425 / 900
392 / 830
359 / 760
335 / 710
l/s / CFM
l/s / CFM
l/s / CFM
l/s / CFM
Pa (in.wg.)
EXTERNAL STATIC PRESSURE(LOW STATIC, H/M/L)
Pa (in.wg.)
dBA
SOUND PRESSURE LEVEL(LOW STATIC, H/M/L)
48 / 47 / 46 / 4546 / 44 / 43 / 4243 / 41 / 40 / 3841 / 40 / 39 / 36dBA
mm/in
mm/in
mm/in
kg/lb
mm/inmm/in
NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 (NON DUCTED PRODUCT) OR ISO13253 (DUCTED PRODUCT).3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO GB/D17758 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.4M BELOW THE UNIT (FREE RETURN AND THE DISCHARGE AIR WAS DUCTED TO ADJACENT ROOM).5) ALL INDOOR MODELS CAN BE USED FOR COOLING ONLY OR HEATPUMP APPLICATION.
NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 (NON DUCTED PRODUCT) OR ISO13253 (DUCTED PRODUCT).3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE ACCORDING TO GB/D17758 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.4M BELOW THE UNIT (FREE RETURN AND THE DISCHARGE AIR WAS DUCTED TO ADJACENT ROOM).
MDBD
Btu/hW
Btu/hW
V/Ph/Hz
l/s / CFMl/s / CFMl/s / CFM
EXTERNAL STATIC PRESSURE (H/M/L) Pa (in.wg.)dBA
mm/inmm/inmm/inkg/lb
LIQUID mm/inGAS mm/in
MDBD 080764002240085300
1700
1167 / 24721034 / 2201833 / 1766100 / 0.40
420 / 16.5
28.6 / 1 1/8
MODEL
AIR FLOW
DEPTH
LOW
CONTROL
UNIT DIMENSION HEIGHT
INDOOR UNIT
REFRIGERANT CONTROL (EXPANSION DEVICE)
HIGH MEDIUM
AIR DISCHARGEOPERATION
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
POWER SOURCE
WIDTH
SOUND PRESSURE LEVEL (H/M/L)
WEIGHT
1690 / 66.5879 / 34.6100 / 220
PIPE CONNECTIONTYPE
SIZE12.7 / 1/2 12.7 / 1/2
WNOMINAL TOTAL INPUT POWER
REFRIGERANT TYPE
IND
OO
R U
NIT
MDBD 1009550028000107500
148025000 31500
1389 / 2943--
150 / 0.60
520 / 20.51580 / 62.2
57 / 55 / 52 57
1020 / 40.2150 / 330
28.6 / 1 1/8
220 ~ 240 / 1 / 50 380 ~ 415 / 3 / 50
EXV
WIRED CONTROLDUCTED
FLARE VALVE
R-22
R-410A Outdoor Specification
R-410A1
R-410A2
5MDS-B
5MDS 050BR 5MDS 060BR 5MDS 070BR
Btu/h 46,000 51,100 64,800
W 13,500 15,000 19,000
Btu/h 51,100 59,700 71,600
W 15,000 17,500 21,000
COOLING W 4,400 4,900 <4,700> 6,400
HEATING W 4,300 4,800 <4,400> 6,200
5MDS 050B 5MDS 060B 5MDS 070B
Btu/h 46,000 51,100 64,800
W 13,500 15,000 19,000
W 4,400 4,900 <4,700> 6,400
V/Ph/Hz 380-415 / 3 / 50 220-240/1/50 <380-415 / 3 / 50> 380-415 / 3 / 50
R-410A R-410A R-410A
l/s / cfm 611 + 611 / 1295 + 1295 833 + 833 / 1766 + 1766 889 + 889 / 1883 + 1883
dB(A) 59 60 62
HEIGHT mm/in 1044 / 41.4 1247 / 49.1 1349 / 53.1
WIDTH mm/in 1058 / 41.7 1058 / 41.7 1058 / 41.7
DEPTH mm/in 430 / 16.9 430 / 16.9 430 / 16.9
kg/lb 117 / 258 125 / 276 135 / 297
kg/lb 120 / 265 130 / 287 140 / 309
FLARE / BRAZE FLARE / BRAZE FLARE / BRAZE
LIQUID mm/in 9.5 / 3/8 9.5 / 3/8 9.5 / 3/8
GAS mm/in 15.9 / 5/8 15.9 / 5/8 15.9 / 5/8
HEATPUMPUNIT WEIGHT
SIZE
NOMINAL TOTAL INPUT POWER - 1Ø <3Ø>
POWER SOURCE - 1Ø <3Ø>
REFRIGERANT TYPE
OU
TD
OO
R U
NIT
AIR FLOW
SOUND PRESSURE LEVEL
UNIT DIMENSION
PIPE CONNECTION
TYPE (LIQUID/GAS)
COOLING ONLY
MODEL OUTDOOR UNIT
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
NOMINAL TOTAL INPUT POWER - 1Ø <3Ø>
MODEL OUTDOOR UNIT
NOMINAL COOLING CAPACITY
NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 (NON DUCTED PRODUCT) OR 1SO13253 (DUCTED PRODUCT).3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT THE MACHINE AND 1.42m ABOVE THE MACHINE BASE.5) THE VALUE OF REFRIGERANT CHARGE IS THE REFRIGERANT CHARGED IN THE OUTDOOR UNIT BEFORE LEAVING FACTORY. THIS CHARGE DOES NOT INCLUDE THE AMOUNT NEEDED FOR EXTENDED PIPING.
5MDS-B
5MDS 080BR 5MDS 100BR 5MDS 120BR 5MDS 140BR 5MDS 160BR
Btu/h 85,300 95,536 112,596 129,656 143,304
W 25,000 28,000 33,000 38,000 42,000
Btu/h 95,536 109,184 126,244 143,304 160,364
W 28,000 32,000 37,000 42,000 47,000
COOLING W 7,200 8,000 9,700 11,300 12,900
HEATING W 7,000 7,900 9,400 10,900 11,900
5MDS 080B 5MDS 100B 5MDS 120B 5MDS 140B 5MDS 160B
Btu/h 85,300 95,536 112,596 129,656 143,304
W 25,000 28,000 33,000 38,000 42,000
W 7,200 8,000 9,700 11,300 12,900
V/Ph/Hz 380 - 415 / 3 / 50 380 - 415 / 3 / 50 380 - 415 / 3 / 50 380 - 415 / 3 / 50 380 - 415 / 3 / 50
R-410A R-410A R-410A R-410A R-410A
HI-FAN l/s / cfm 3056 / 6474 3056 / 6474 3056 / 6474 3333 / 7063 3333 / 7063
LOW-FAN l/s / cfm 1611 / 3414 1611 / 3414 1611 / 3414 1778 / 3767 1778 / 3767
dB(A) 56 57 60 60 60
HEIGHT mm/in 1840 / 72.4 1840 / 72.4 1840 / 72.4 1840 / 72.4 1840 / 72.4
WIDTH mm/in 990 / 39.0 990 / 39.0 990 / 39.0 1290 / 50.8 1290 / 50.8
DEPTH mm/in 840 / 33.1 840 / 33.1 840 / 33.1 840 / 33.1 840 / 33.1
kg/lb 275 / 606 285 / 628 290 / 639 335 / 739 345 / 761
kg/lb 290 / 639 300 / 661 305 / 672 350 / 771 360 / 793
Flare / Brazed Flare / Brazed Flare / Brazed Flare / Brazed Flare / Brazed
LIQUID mm/in 9.5 / 3/8 12.7 / 1/2 12.7 / 1/2 12.7 / 1/2 12.7 / 1/2
GAS mm/in 22.2 / 7/8 22.2 / 7/8 22.2 / 7/8 28.6 / 1 1/8 28.6 / 1 1/8
kg/lb 7.9 / 17.4 9.2 / 20.3 10.6 / 23.4 12.2 / 26.9 13.4 / 29.5
UNIT WEIGHTCOOLING ONLY
HEATPUMP
OUTDOOR UNIT
NOMINAL COOLING CAPACITY
NOMINAL TOTAL INPUT POWER
MODEL
REFRIGERANT CHARGE
POWER SOURCE
REFRIGERANT TYPE
OU
TD
OO
R U
NIT
AIR FLOW
SOUND PRESSURE LEVEL
UNIT DIMENSION
PIPE CONNECTION
OUTDOOR UNIT
TYPE (LIQUID/GAS)
SIZE
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
NOMINAL TOTAL INPUT POWER
MODEL
NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 (NON DUCTED PRODUCT) OR ISO 13253 (DUCTED PRODUCT).3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT THE MACHINE AND 1.42m ABOVE THE MACHINE BASE.5) THE VALUE OF REFRIGERANT CHARGE IS THE REFRIGERANT CHARGED IN THE OUTDOOR UNIT BEFORE LEAVING FACTORY. THIS CHARGE DOES NOT INCLUDE THE AMOUNT NEEDED FOR EXTENDED PIPING.
5MDS-B5MDS 280BR 5MDS 300BR 5MDS 320BR 5MDS 340BR 5MDS 360BR
5MDS 120BRM + 5MDS 160BRS 5MDS 120BRM + 5MDS 180BRS 5MDS 180BRM + 5MDS 140BRS 5MDS 180BRM + 5MDS 160BRS 5MDS 180BRM + 5MDS 180BRS
Btu/h 255,900 272,960 290,020 303,668 320,728
W 75,000 80,000 85,000 89,000 94,000
Btu/h 286,608 307,080 324,140 341,200 361,672
W 84,000 90,000 95,000 100,000 106,000
COOLING W 22,600 24,200 25,800 27,400 29,000
HEATING W 21,300 23,200 24,700 25,700 27,600
5MDS 280B 5MDS 300B 5MDS 320B 5MDS 340B 5MDS 360B
5MDS 120BM + 5MDS 160BS 5MDS 120BM + 5MDS 180BS 5MDS 180BM + 5MDS 140BS 5MDS 180BM + 5MDS 160BS 5MDS 180BM + 5MDS 180BS
Btu/h 255,900 272,960 290,020 303,668 320,728
W 75,000 80,000 85,000 89,000 94,000
W 22,600 24,200 25,800 27,400 29,000
V/Ph/Hz 380 - 415 / 3 / 50 380 - 415 / 3 / 50 380 - 415 / 3 / 50 380 - 415 / 3 / 50 380 - 415 / 3 / 50
R-410A R-410A R-410A R-410A R-410A
HI-FAN l/s / cfm 3056 + 3333 / 6474 + 7063 3056 + 3472 / 6474 + 7357 3472 + 3333 / 7357 + 7063 3472 + 3333 / 7357 + 7063 3472 + 3472 / 7357 + 7357
LOW-FAN l/s / cfm 1611 + 1778 / 3414 + 3767 1611 + 2083 / 3414 + 4414 2083 + 1778 / 4414 + 3767 2083 + 1778 / 4414 + 3767 2083 + 2083 / 4414 + 4414
dB(A) 62 62 63 63 63
HEIGHT mm/in 1840 / 72.4 1840 / 72.4 1840 / 72.4 1840 / 72.4 1840 / 72.4
WIDTH mm/in 2290 / 90.2 2290 / 90.2 2590 / 102.0 2590 / 102.0 2590 / 102.0
DEPTH mm/in 840 / 33.1 840 / 33.1 840 / 33.1 840 / 33.1 840 / 33.1
kg/lb 635 / 1400 645 / 1422 690 / 1521 700 / 1543 710 / 1565
kg/lb 665 / 1466 675 / 1488 720 / 1587 730 / 1609 740 / 1631
Flare / Brazed Flare / Brazed Flare / Brazed Flare / Brazed Flare / Brazed
LIQUID mm/in 15.9 / 5/8 15.9 / 5/8 19.1 / 3/4 19.1 / 3/4 19.1 / 3/4
GAS mm/in 34.9 / 1 3/8 34.9 / 1 3/8 34.9 / 1 3/8 34.9 / 1 3/8 34.9 / 1 3/8
kg/lb 24.0 / 52.9 30.0 / 66.1 32.0 / 70.5 34.0 / 75.0 34.0 / 75.0
UNITWEIGHT
COOLING ONLY
HEATPUMP
REFRIGERANT CHARGE
POWER SOURCE
REFRIGERANT TYPE
OU
TD
OO
R U
NIT
AIR FLOW
SOUND PRESSURE LEVEL
TYPE (LIQUID/GAS)
SIZE
UNIT DIMENSION
PIPECONNECTION
NOMINAL TOTALINPUT POWER
NOMINAL TOTAL INPUT POWER
MODELOUTDOOR UNIT
NOMINAL COOLING CAPACITY
MASTER UNIT+SLAVE UNIT
OUTDOOR UNIT
MASTER UNIT+SLAVE UNIT
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
MODEL
5MDS-B
5MDS 180BR 5MDS 200BR 5MDS 220BR 5MDS 240BR 5MDS 260BR
- - - - 5MDS 120BRM + 5MDS 140BRS
Btu/h 160,364 180,836 197,896 218,368 242,252
W 47,000 53,000 58,000 64,000 71,000
Btu/h 180,836 201,308 221,780 242,252 269,548
W 53,000 59,000 65,000 71,000 79,000
COOLING W 14,500 16,200 17,700 19,800 21,000
HEATING W 13,800 14,700 16,900 18,500 20,300
5MDS 180B 5MDS 200B 5MDS 220B 5MDS 240B 5MDS 260B
- - - - 5MDS 120BM + 5MDS 140BS
Btu/h 160,364 180,836 197,896 218,368 242,252
W 47,000 53,000 58,000 64,000 71,000
W 14,500 16,200 17,700 19,800 21,000
V/Ph/Hz 380 - 415 / 3 / 50 380 - 415 / 3 / 50 380 - 415 / 3 / 50 380 - 415 / 3 / 50 380 - 415 / 3 / 50
R-410A R-410A R-410A R-410A R-410A
HI-FAN l/s / cfm 3472 / 7357 3056 +3056 / 6474 +6474 3056 + 3056 / 6474 + 6474 3056 + 3056 / 6474 + 6474 3056 + 3333 / 6474 + 7063
LOW-FAN l/s / cfm 2083 / 4414 1611 + 1611 / 3414 + 3414 1611 + 1611 / 3414 + 3414 1611 + 1611 / 3414 + 3414 1611 + 3414 / 1778 + 3767
dB(A) 61 61 62 62 62
HEIGHT mm/in 1840 / 72.4 1840 / 72.4 1840 / 72.4 1840 / 72.4 1840 / 72.4
WIDTH mm/in 1290 / 50.8 1990 / 78.3 1990 / 78.3 1990 / 78.3 2290 / 90.2
DEPTH mm/in 840 / 33.1 840 / 33.1 840 / 33.1 840 / 33.1 840 / 33.1
kg/lb 355 / 783 560 / 1235 560 / 1235 570 / 1257 625 / 1378
kg/lb 370 / 816 590 / 1301 590 / 1301 600 / 1323 655 / 1444
Flare / Brazed Flare / Brazed Flare / Brazed Flare / Brazed Flare / Brazed
LIQUID mm/in 12.7 / 1/2 15.9 / 5/8 15.9 / 5/8 15.9 / 5/8 15.9 / 5/8
GAS mm/in 28.6 / 1 1/8 28.6 / 1 1/8 28.6 / 1 1/8 28.6 / 1 1/8 34.9 / 1 3/8
kg/lb 14.8 / 32.6 18.0 / 39.7 19.6 / 43.2 21.5 / 47.4 22.8 / 50.3
MODELMASTER UNIT+SLAVE UNIT
MODELMASTER UNIT+SLAVE UNIT
OUTDOOR UNIT
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
HEATPUMP
NOMINAL TOTALINPUT POWER
POWER SOURCE
REFRIGERANT TYPE
NOMINAL COOLING CAPACITY
NOMINAL TOTAL INPUT POWER
OUTDOOR UNIT
OU
TD
OO
R U
NIT
PIPECONNECTION
TYPE (LIQUID/GAS)
SIZE
REFRIGERANT CHARGE
AIR FLOW
SOUND PRESSURE LEVEL
UNIT DIMENSION
UNITWEIGHT
COOLING ONLY
R-410A Indoor Specifications
IND
OO
R U
NIT
M5WMD-G
HIGH
MEDIUM
LOW
HEIGHT
WIDTH
DEPTH
LIQUID
GAS
INDOOR MODEL
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
SIZE
POWER SOURCE
REFRIGERANT TYPE
REFRIGERANT CONTROL (EXPANSION DEVICE)
SOUND PRESSURE LEVEL (H/M/L)
UNIT WEIGHT
UNIT DIMENSION
AIR FLOW
PIPE CONNECTION
TYPE
M5WMD 009G2 M5WMD 010G2 M5WMD 015G2
Btu/h 8500 9600 12300
W 2500 2800 3600
Btu/h 9600 10900 13600
W 2800 3200 4000
V/Ph/Hz
l/s / cfm 130 / 275 142 / 300 163 / 345
l/s / cfm 106 / 225 118 / 250 135 / 285
R-410A
EXV
l/s / cfm 83 / 175 94 / 200 104 / 220
dBA 40 / 35 / 29 39 / 34 / 28 42 / 36 / 29
mm/in
mm/in 799 / 31.5
mm/in
kg/lb 10 / 22.0
mm/in
mm/in 12.7 / 1/2
220-240/1/50
FLARE VALVE
9.5 / 3/8
12 / 26.5
899 / 35.4
6.4 / 1/4
260 / 10.2
198 / 7.8
NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151. (NON DUCTED PRODUCT) OR ISO13253 (DUCTED PRODUCT).3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVELS ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 0.8m BELOW THE UNIT.5) ALL INDOOR MODELS CAN BE USED FOR COOLING ONLY OR HEATPUMP APPLICATION.
IND
OO
R U
NIT
HIGH
MEDIUM
LOW
HEIGHT
WIDTH
DEPTH
LIQUID
GAS
INDOOR MODEL
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
POWER SOURCE
AIR FLOW
SOUND PRESSURE LEVEL (H/M/L)
UNIT DIMENSION
UNIT WEIGHT
PIPE CONNECTION
TYPE
SIZE
M5WMD 025G2
Btu/h 22200
W 6500
Btu/h 25200
W 7400
V/Ph/Hz
l/s / cfm 397 / 630
l/s / cfm 231 / 490
l/s / cfm 208 / 440
dBA 49 / 44 / 42
mm/in
mm/in
mm/in
kg/lb
mm/in
mm/in
16 / 35.3
FLARE VALVE
6.4 / 1/4
15.9 / 5/8
220-240/1/50
304 / 12.0
1062 / 41.8
222 / 8.7
M5WMD 020G2
19100
5600
21500
6300
REFRIGERANT TYPE
REFRIGERANT CONTROL (EXPANSION DEVICE) EXV
R-410A
231 / 490
193 / 410
160 / 340
43 / 40 / 35
12.7 / 1/2
M5WMD-G
R-410A3
R-410A4
5MDS-B5MDS 380BR 5MDS 400BR 5MDS 420BR 5MDS 440BR
5MDS 240BRM + 5MDS 140BRS 5MDS 240BRM + 5MDS 160BRS 5MDS 240BRM + 5MDS 180BRS 5MDS 240BRM + 5MDS 200BRS
Btu/h 348,024 361,672 378,732 399,204
W 102,000 106,000 111,000 117,000
Btu/h 385,556 402,616 423,088 443,560
W 113,000 118,000 124,000 130,000
COOLING W 31,100 32,700 34,300 36,000
HEATING W 29,400 30,400 32,300 33,200
5MDS 380B 5MDS 400B 5MDS 420B 5MDS 440B
5MDS 240BM + 5MDS 140BS 5MDS 240BM + 5MDS 160BS 5MDS 240BM + 5MDS 180BS 5MDS 240BM + 5MDS 200BS
Btu/h 348,024 361,672 378,732 399,204
W 102,000 106,000 111,000 117,000
W 31,100 32,700 34,300 36,000
V/Ph/Hz 380 - 415 / 3 / 50 380 - 415 / 3 / 50 380 - 415 / 3 / 50 380 - 415 / 3 / 50
R-410A R-410A R-410A R-410A
HI-FAN l/s / cfm 3056 x 2 + 3333 / 6474 x 2 + 7063 3056 x 2 + 3333 / 6474 x 2 + 7063 3056 x 2 + 3472 / 6474 x 2 + 7357 3056 x 4 / 6474 x 4
LOW-FAN l/s / cfm 1611 x 2 + 1778 / 3414 x 2 + 3767 1611 x 2 + 1778 / 3414 x 2 + 3767 1611 x 2 + 2222 / 3414 x 2 + 4414 1611 x 4 / 3414 x 4
dB(A) 64 65 65 65
HEIGHT mm/in 1840 / 72.4 1840 / 72.4 1840 / 72.4 1840 / 72.4
WIDTH mm/in 3290 / 129.5 3290 / 129.5 3290 / 129.5 3990 / 157.1
DEPTH mm/in 840 / 33.1 840 / 33.1 840 / 33.1 840 / 33.1
kg/lb 905 / 1995 915 / 2017 925 / 2039 1130 / 2491
kg/lb 950 / 2094 960 / 2116 970 / 2138 1190 / 2624
Flare / Brazed Flare / Brazed Flare / Brazed Flare / Brazed
LIQUID mm/in 19.1 / 3/4 19.1 / 3/4 19.1 / 3/4 19.1 / 3/4
GAS mm/in 41.3 / 1 5/8 41.3 / 1 5/8 41.3 / 1 5/8 41.3 / 1 5/8
kg/lb 38.0 / 83.4 40.0 / 88.2 42.0 / 92.6 44.0 / 97.0
NOMINAL COOLING CAPACITY
REFRIGERANT CHARGE
POWER SOURCE
REFRIGERANT TYPE
OU
TD
OO
R U
NIT
AIR FLOW
SOUND PRESSURE LEVEL
TYPE (LIQUID/GAS)
SIZE
UNIT DIMENSION
PIPE CONNECTION
UNIT WEIGHTCOOLING ONLY
HEATPUMP
NOMINAL TOTAL INPUT POWER
MODELOUTDOOR UNIT
MODELOUTDOOR UNIT
MASTER UNIT+SLAVE UNIT
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
NOMINAL TOTAL INPUT POWER
MASTER UNIT+SLAVE UNIT
NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151. (NON DUCTED PRODUCT) OR ISO13253 (DUCTED PRODUCT).3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT THE MACHINE AND 1.42m ABOVE THE MACHINE BASE.5) THE VALUE OF REFRIGERANT CHARGE IS THE REFRIGERANT CHARGED IN THE OUTDOOR UNIT BEFORE LEAVING FACTORY. THIS CHARGE DOES NOT INCLUDE THE AMOUNT NEEDED FOR EXTENDED PIPING.
5MDS-B5MDS 460BR 5MDS 480BR 5MDS 500BR
5MDS 240BRM + 5MDS 220BRS 5MDS 240BRM + 5MDS 240BRS 5MDS 250BRM + 5MDS 250BRS
Btu/h 416,264 436,736 457,208
W 122,000 128,000 134,000
Btu/h 464,032 484,504 504,976
W 136,000 142,000 148,000
COOLING W 37,500 39,600 41,800
HEATING W 35,400 37,000 39,000
5MDS 460B 5MDS 480B 5MDS 500B
5MDS 240BM + 5MDS 220BS 5MDS 240BM + 5MDS 240BS 5MDS 250BM + 5MDS 250BS
Btu/h 416,264 436,736 457,208
W 122,000 128,000 134,000
W 37,500 39,600 41,800
V/Ph/Hz 380 - 415 / 3 / 50 380 - 415 / 3 / 50 380 - 415 / 3 / 50
R-410A R-410A R-410A
HI-FAN l/s / cfm 3056 x 4 / 6474 x 4 3056 x 4 / 6474 x 4 3056 x 4 / 6474 x 4
LOW-FAN l/s / cfm 1611 x 4 / 3414 x 4 1611 x 4 / 3414 x 4 1611 x 4 / 3414 x 4
dB(A) 65 65 65
HEIGHT mm/in 1840 / 72.4 1840 / 72.4 1840 / 72.4
WIDTH mm/in 3990 / 157.1 3990 / 157.1 3990 / 157.1
DEPTH mm/in 840 / 33.1 840 / 33.1 840 / 33.1
kg/lb 1130 / 2491 1140 / 2513 1160 / 2557
kg/lb 1190 / 2624 1200 / 2646 1220 / 2690
Flare / Brazed Flare / Brazed Flare / Brazed
LIQUID mm/in 19.1 / 3/4 19.1 / 3/4 19.1 / 3/4 GAS mm/in 41.3 / 1 5/8 41.3 / 1 5/8 41.3 / 1 5/8
kg/lb 46.0 / 101.4 48.0 / 105.8 50.0 / 110.2
MODELOUTDOOR UNIT
MASTER UNIT+SLAVE UNIT
UNIT WEIGHTCOOLING ONLY
HEATPUMP
NOMINAL COOLING CAPACITY
REFRIGERANT CHARGE
REFRIGERANT TYPE
OU
TD
OO
R U
NIT
AIR FLOW
SOUND PRESSURE LEVEL
UNIT DIMENSION
PIPE CONNECTION
TYPE (LIQUID/GAS)
SIZE
NOMINAL HEATING CAPACITY
NOMINAL TOTAL INPUT POWER
POWER SOURCE
MODELOUTDOOR UNIT
MASTER UNIT+SLAVE UNIT
NOMINAL COOLING CAPACITY
NOMINAL TOTAL INPUT POWER
R-410A5
R-410A6
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 (NON DUCTED PRODUCT) OR ISO13253 (DUCTED PRODUCT).3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4a) M5CKD020-025A: SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.4m BELOW FASCIA4b) M5CKD030-040A: SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.5m BELOW FASCIA.5) ALL INDOOR MODELS CAN BE USED FOR COOLING ONLY OR HEATPUMP APPLICATION.
IND
OO
R U
NIT
M5CKD-A
LIQUID
GAS
HIGH
MEDIUM
HEIGHT
SOUND PRESSURE LEVEL (H/M/L)
DEPTH
PIPE CONNECTION
TYPE
SIZE
INDOOR MODEL
LOW
POWER SOURCE
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
WIDTH
AIR FLOW
WEIGHT (UNIT + PANEL)
UNIT DIMENSION ( ) - WITH PANEL
REFRIGERANT TYPE
REFRIGERANT CONTROL (EXPANSION DEVICE)
M5CKD 020A M5CKD 025A M5CKD 030A M5CKD 040A M5CKD 050A
19100 22200 30700 38200 47800
5600 6500 9000 11200 14000
21500 25200 34100 42700 54600
6300 7400 10000 12500 16000
349 / 740 368 / 780 415 / 880 467 / 990 491 / 1040
297 / 630 311 / 660 349 / 740 406 / 860 448 / 950
283 / 600 283 / 600 321 / 680 359 / 760 411 / 870
42 / 39 / 37 45 / 42 / 40 49 / 45 / 43 51 / 48 / 46 53 / 52 / 50
31 + 4 / 68.3 + 8.8 32 + 4 / 70.5 + 8.8 35 + 4 / 77.2 + 8.8 38 + 4 / 83.8 + 8.8 40 + 4 / 88.2 + 8.8
6.4 / 1/4 6.4 / 1/4 9.5 / 3/8 9.5 / 3/8 9.5 / 3/8
12.7 / 1/2 15.9 / 5/8 15.9 / 5/8 15.9 / 5/8 15.9 / 5/8
820 (930) / 32.2 (36.6)
220-240/1/50
R-410A
EXV
335 (378) / 13.2 (14.9)
820 (930) / 32.2 (36.6)
FLARE VALVE
Btu/h
W
Btu/h
W
V/Ph/Hz
l/s / CFM
l/s / CFM
l/s / CFM
dBA
mm/in
mm/in
mm/in
kg/lb
mm/in
mm/in
M5CKD-C
LIQUID
GAS
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 (NON DUCTED PRODUCT) OR ISO13253 (DUCTED PRODUCT).3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.5) ALL INDOOR MODELS CAN BE USED FOR COOLING ONLY OR HEATPUMP APPLICATION.
UNIT WEIGHT (UNIT + PANEL)
PIPE CONNECTION
TYPE
SIZE
DEPTH
LOW
UNIT DIMENSION ( ) - WITH PANEL
IND
OO
R U
NIT
POWER SOURCE
AIR FLOW
HIGH
SOUND PRESSURE LEVEL (H/M/L)
HEIGHT
WIDTH
INDOOR MODEL
MEDIUM
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
M5CKD 010C M5CKD 015C M5CKD 020C
9600 12300 19100
2800 3600 5600
10900 13600 21500
3200 4000 6300
194 / 410 194 / 410 212 / 450
170 / 360 170 / 360 194 / 410
156 / 330 156 / 330 160 / 340
41 / 38 / 35 41 / 38 / 34 44 / 41 / 37
22 + 2 / 48.5 + 4.4 23 + 2 / 50.7 + 4.4 23 + 2 / 50.7 + 4.4
FLARE VALVE
6.4 / 1/4
9.5 / 3/8 12.7 / 1/2 12.7 / 1/2
220 - 240 / 1 / 50
250 (295) / 9.8 (11.6)
570 (640) / 22.4 (25.2)
570 (640) / 22.4 (25.2)
FLARE VALVE
Btu/h
W
Btu/h
W
V/Ph/Hz
REFRIGERANT CONTROL (EXPANSION DEVICE) EXV
REFRIGERANT TYPE R-410A
l/s / CFM
l/s / CFM
l/s / CFM
dBA
mm/in
mm/in
mm/in
kg/lb
mm/in
mm/in
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 (NON DUCTED PRODUCT) OR ISO13253 (DUCTED PRODUCT).3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 0.8m BELOW THE UNIT.5) ALL INDOOR MODELS CAN BE USED FOR COOLING ONLY OR HEATPUMP APPLICATION.
M5CMD-E
LIQUID
GAS
LOW
NOMINAL COOLING CAPACITY
SOUND PRESSURE LEVEL (H/M/L)
AIR FLOW
HIGH
MEDIUM
NOMINAL HEATING CAPACITY
POWER SOURCE
PIPE CONNECTION
TYPE
SIZE
UNIT WEIGHT
WIDTH
HEIGHT
DEPTH
INDOOR MODEL
IND
OO
R U
NIT
UNIT DIMENSION
M5CMD 015E M5CMD 020E M5CMD 025E M5CMD 028E
12300 19100 22200 27300
3600 5600 6500 8000
13600 21500 25200 30700
4000 6300 7400 9000
240 / 508 245 / 520 274 / 580 302 / 640
182 / 386 217 / 460 250 / 530 264 / 560
165 / 350 192 / 406 231 / 490 217 / 460
48 / 43 / 41 48 / 46 / 43 50 / 47 / 46 51 / 48 / 47
26 / 57.3 27 / 59.5 27 / 59.5 28 / 61.7
9.5 / 3/8
218 / 8.6
1080 / 42.5
630 / 24.8
220 - 240 / 1 / 50
REFRIGERANT TYPE R-410A
REFRIGERANT CONTROL (EXPANSION DEVICE) EXV
FLARE VALVE
12.7 / 1/2
6.4 / 1/4
15.9 / 5/8
Btu/h
W
Btu/h
W
V/Ph/Hz
l/s / CFM
l/s / CFM
l/s / CFM
dBA
mm/in
mm/in
mm/in
kg/lb
mm/in
mm/in
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 (NON DUCTED PRODUCT) OR ISO13253 (DUCTED PRODUCT).3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.5) ALL INDOOR MODELS CAN BE USED FOR COOLING ONLY OR HEATPUMP APPLICATION.
IND
OO
R U
NIT
M5CMD-D/C
LIQUID
GAS
PIPE CONNECTION
TYPE
SIZE
SOUND PRESSURE LEVEL (H/M/L)
UNIT WEIGHT
UNIT DIMENSION
HEIGHT
WIDTH
DEPTH
AIR FLOW
HIGH
MEDIUM
LOW
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
POWER SOURCE
INDOOR MODEL M5CMD 040D M5CMD 050D M5CMD 062C
Btu/h 38200 47800 56000
W 11200 14000 16400
Btu/h 42700 54600 63100
W 12500 16000 18500
V/Ph/Hz
l/s / CFM 477 / 1010 491 / 1040 732 / 1550
l/s / CFM 420 / 890 448 / 950 623 / 1320
l/s / CFM 368 / 780 387 / 820 472 / 1000
dBA 54 / 53 / 52 54 / 53 / 52 56 / 53 / 46
mm/in 285 / 11.2
mm/in 1903 / 74.9
mm/in 680 / 26.8
kg/lb 85 / 187.4
mm/in
mm/in 19.1 / 3/4
670 / 26.3
220 - 240 / 1 / 50
REFRIGERANT TYPE
REFRIGERANT CONTROL (EXPANSION DEVICE)
R-410A
EXV
70 / 154.3
249 / 9.8
FLARE VALVE
9.5 / 3/8
15.9 / 5/8
1714 / 67.4
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 (NON DUCTED PRODUCT) OR ISO13253 (DUCTED PRODUCT).3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO GB/D17758 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.4M BELOW THE UNIT (FREE RETURN AND THE DISCHARGE AIR WAS DUCTED TO ADJACENT ROOM).5) ALL INDOOR MODELS CAN BE USED FOR COOLING ONLY OR HEATPUMP APPLICATION.
M5CCD-C
Btu/h 9600 12300 19100 22200 27300
W 2800 3600 5600 6500 8000
Btu/h 10900 13600 21500 25200 30700
W 3200 4000 6300 7400 9000
V/Ph/Hz
l/s / CFM 118 / 250 194 / 410 270 / 570 326 / 690 382 / 810
l/s / CFM 112 / 235 175 / 370 264 / 558 312 / 660 363 / 770
l/s / CFM 100 / 210 118 / 250 227 / 480 253 / 535 335 / 710
EXTERNAL STATIC PRESSURE (SH/H/M/L) Pa (in.wg.)29 / 20 / 10
(0.12 / 0.08 / 0.04) (0.12 / 0.08 / 0.04) (0.12 / 0.08 / 0.04) (0.4 / 0.3 / 0.3 / 0.2)29 / 20 / 10 29 / 20 / 10 29 / 20 / 10
(0.12 / 0.08 / 0.04)98 / 78 / 68 / 59
dBA 33 / 30 / 26 37 / 34 / 29 38 / 36 / 34 40 / 39 / 36 44 / 41 / 38 / 34
mm/in 285 / 11.2
mm/in 765 / 30.1 905 / 35.6 1065 / 41.9 1200 / 47.2 1007 / 39.6
mm/in 600 / 23.6
kg/lb 17 / 37.5 21 / 46.3 22 / 48.5 25 / 55.1 38 / 83.8
LIQUID mm/in 9.5 / 3/8GAS mm/in 9.5 / 3/8
220 - 240 / 1 / 50
PIPE CONNECTION
TYPE
SIZE15.9 / 5/8
WEIGHT
UNIT DIMENSION
LOW
SOUND PRESSURE LEVEL (SH/H/M/L)
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
HIGH
MEDIUM
POWER SOURCE
AIR FLOW
WIDTH
HEIGHT
DEPTH
INDOOR MODEL
FLARE VALVE
411 / 16.2
6.4 / 1/412.7 / 1/2
261 / 10.3
R-410A
EXV
REFRIGERANT TYPE
REFRIGERANT CONTROL (EXPANSION DEVICE)
l/s / CFM - - - - 401 / 850SUPER HIGH
IND
OO
R U
NIT
M5CCD 010C M5CCD 015C M5CCD 020C M5CCD 025C M5CCD 028C
Btu/h 30700 34100 38200 47800 56000
W 9000 10000 11200 14000 16400
Btu/h 34100 38200 42700 54600 63100
W 10000 11200 12500 16000 18500
V/Ph/Hz
l/s / CFM 604 / 1280 675 / 1430 812 / 1720
l/s / CFM 547 / 1160 623 / 1320 732 / 1550
l/s / CFM 496 / 1050 580 / 1230 632 / 1340
l/s / CFM 434 / 920 533 / 1130 552 / 1170
EXTERNAL STATIC PRESSURE (SH/H/M/L) Pa (in.wg.) 118 / 96 / 78 / 61 (0.5 / 0.4 / 0.3 / 0.2) (0.5 / 0.4 / 0.3 / 0.2) (0.6 / 0.5 / 0.4 / 0.3) (0.6 / 0.5 / 0.4 / 0.3)
147 / 126 / 109 / 92 147 / 120 / 90 / 69
dBA 52 / 49 / 48 / 45
566 / 1200
486 / 1030
406 / 860
349 / 740
120 / 86 / 64 / 45(0.5 / 0.3 / 0.3 / 0.2)
52 / 49 / 48 / 45 54 / 53 / 52 / 51
628 / 1330
571 / 1210
491 / 1040
425 / 900
120 / 98 / 74 / 54
51 / 49 / 45 / 41 54 / 52 / 50 / 46
mm/in 378 / 14.9 305 / 12.0 378 / 14.9 378 / 14.9 378 / 14.9
mm/in 929 / 36.6 1302 / 51.3 1045 / 41.1 1299 / 51.1 1499 / 59.0
mm/in 514 / 21.3 638 / 25.1 541 / 21.3 541 / 21.3 541 / 21.3
kg/lb 39 / 86.0 41 / 90.4 42 / 92.6 54 / 119.1 62 / 136.7
LIQUID mm/inGAS mm/in 19.1 / 3/4
220 - 240 / 1 / 50
AIR FLOW
LOW
POWER SOURCE
HIGH
PIPE CONNECTION
TYPE
SIZE
DEPTH
WEIGHT
UNIT DIMENSION
9.5 / 3/815.9 / 5/8
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
MEDIUM
SUPER HIGH
HEIGHT
SOUND PRESSURE LEVEL (SH/H/M/L)
WIDTH
INDOOR MODEL
FLARE VALVE
IND
OO
R U
NIT
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 (NON DUCTED PRODUCT) OR ISO13253 (DUCTED PRODUCT).3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO GB/D17758 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.4M BELOW THE UNIT (FREE RETURN AND THE DISCHARGE AIR WAS DUCTED TO ADJACENT ROOM).5) ALL INDOOR MODELS CAN BE USED FOR COOLING ONLY OR HEATPUMP APPLICATION.
R-410A
EXVREFRIGERANT CONTROL (EXPANSION DEVICE)
REFRIGERANT TYPE
M5CCD-CM5CCD 030C M5CCD 038C M5CCD 040C M5CCD 050C M5CCD 060C
R-410A7