AN UNIT OVERVIEW OF THERMAL POWER PLANT
(KTPS V-STAGE)PRESENTATION BY
G.RAKESH(107Z1A0221)K.S.S.VENKATA SATYA NAVEEN(107Z1A0222)
UNDER ESTEEMED GUIDANCE OF K.SWATHI
![Page 2: An Overview of Thermal Power Plant](https://reader030.vdocument.in/reader030/viewer/2022012405/554a5075b4c90531228b4a68/html5/thumbnails/2.jpg)
ABSTRACT
The main aim of this project is to study the various types of electrical and mechanical equipment involved in the process of generation of Electrical power.
![Page 3: An Overview of Thermal Power Plant](https://reader030.vdocument.in/reader030/viewer/2022012405/554a5075b4c90531228b4a68/html5/thumbnails/3.jpg)
INTRODUCTION
KTPS-V Station was commissioned in 1996.
It was the first major thermal power station in AP.
KTPS V Stage had achieved 94.5% plant load factor.
![Page 4: An Overview of Thermal Power Plant](https://reader030.vdocument.in/reader030/viewer/2022012405/554a5075b4c90531228b4a68/html5/thumbnails/4.jpg)
WORKING PRINCIPLE
The thermal power station is a power plant in which the prime mover is steam driven.
Water is heated, turns into steam and spins a steam turbine which drives an electrical generator.
The coal is used as a major source of fuel.
The thermal power plant works on the principle of “Rankine cycle”.
![Page 5: An Overview of Thermal Power Plant](https://reader030.vdocument.in/reader030/viewer/2022012405/554a5075b4c90531228b4a68/html5/thumbnails/5.jpg)
PARTS OF THERMAL POWER PLANT
![Page 6: An Overview of Thermal Power Plant](https://reader030.vdocument.in/reader030/viewer/2022012405/554a5075b4c90531228b4a68/html5/thumbnails/6.jpg)
![Page 7: An Overview of Thermal Power Plant](https://reader030.vdocument.in/reader030/viewer/2022012405/554a5075b4c90531228b4a68/html5/thumbnails/7.jpg)
TYPES OF CIRCUITS
For simplicity let us divide the whole arrangement into four circuits.
1. Steam and water circuit 2. Air and gas circuit 3. Coal and ash circuit 4. Cooling water circuit.
![Page 8: An Overview of Thermal Power Plant](https://reader030.vdocument.in/reader030/viewer/2022012405/554a5075b4c90531228b4a68/html5/thumbnails/8.jpg)
1.STEAM AND WATER CIRCUIT
boiler Drum Super heater
Hp turbine
Re Heater
IP Turbine
LP Turbine
Condenser
![Page 9: An Overview of Thermal Power Plant](https://reader030.vdocument.in/reader030/viewer/2022012405/554a5075b4c90531228b4a68/html5/thumbnails/9.jpg)
BOILER
A boiler is a device for generating steam for power, processing or heating purposes.
The boiler used here is a two pass, tower type, reheat natural circulation single drum, balanced draft and dry bottom (open hopper type) boiler and is designed for burning coal as principal fuel.
![Page 10: An Overview of Thermal Power Plant](https://reader030.vdocument.in/reader030/viewer/2022012405/554a5075b4c90531228b4a68/html5/thumbnails/10.jpg)
SCHMETIC DIAGRAM OF BOILER
![Page 11: An Overview of Thermal Power Plant](https://reader030.vdocument.in/reader030/viewer/2022012405/554a5075b4c90531228b4a68/html5/thumbnails/11.jpg)
CLASSFICATION OF BOILERS Boilers are mainly classified into two
types. They are
1. Fire tube boiler
2.Water tube boiler
![Page 12: An Overview of Thermal Power Plant](https://reader030.vdocument.in/reader030/viewer/2022012405/554a5075b4c90531228b4a68/html5/thumbnails/12.jpg)
CONDENSER
Condenser is a Surface heat exchanger.
Exhaust steam from LP turbine enters into the condenser, where it condensates into water by exchanging its heat energy to cooling water.
![Page 13: An Overview of Thermal Power Plant](https://reader030.vdocument.in/reader030/viewer/2022012405/554a5075b4c90531228b4a68/html5/thumbnails/13.jpg)
FEED WATER FLOW FROM CONDENSER
Condenser CEPs LPH
DeaeratorBFPs HP
heaters
Economiser Drum boiler
![Page 14: An Overview of Thermal Power Plant](https://reader030.vdocument.in/reader030/viewer/2022012405/554a5075b4c90531228b4a68/html5/thumbnails/14.jpg)
ECONOMISER
An economiser extracts apart of this heat from the flue gases.
It uses extracted heat for heating the feed water before it enters into the steam drum.
![Page 15: An Overview of Thermal Power Plant](https://reader030.vdocument.in/reader030/viewer/2022012405/554a5075b4c90531228b4a68/html5/thumbnails/15.jpg)
2.AIR AND GAS CIRCUIT
PRIMARY AIR FAN(PA FAN) The primary air has got two functions. 1.Pre heating the coal. 2. Transportation of fuel into furnace.
PA fan Air Heater Mills Boiler
![Page 16: An Overview of Thermal Power Plant](https://reader030.vdocument.in/reader030/viewer/2022012405/554a5075b4c90531228b4a68/html5/thumbnails/16.jpg)
FORCED DRAFT FAN(FD FAN)
The function of FD FAN is to supply sufficient quantity of air required for complete combustion.
The air flow is as shown below
FD FanAir
Heater
Furnace
![Page 17: An Overview of Thermal Power Plant](https://reader030.vdocument.in/reader030/viewer/2022012405/554a5075b4c90531228b4a68/html5/thumbnails/17.jpg)
AIR PRE HEATERS
Air pre heater function is to heat the air with the help of flue gases.
The air heater used in KTPS-V is a Regenerative Tri-sector air heater.
The flue gases flow is as shown :
Boiler Air
preheater
ESP ID Fan Chimney
![Page 18: An Overview of Thermal Power Plant](https://reader030.vdocument.in/reader030/viewer/2022012405/554a5075b4c90531228b4a68/html5/thumbnails/18.jpg)
INDUCED DRAFT FAN (ID FAN)
The function of Induced Draft fan is to suck the gases out of furnaces and throw them into the stack.
Boiler is provided with two no. of Induced Draft Fans.
![Page 19: An Overview of Thermal Power Plant](https://reader030.vdocument.in/reader030/viewer/2022012405/554a5075b4c90531228b4a68/html5/thumbnails/19.jpg)
ELECTROSTATIC PRECIPITATOR The main function of ESP is to clean the
gases which are being released into atmosphere.
![Page 20: An Overview of Thermal Power Plant](https://reader030.vdocument.in/reader030/viewer/2022012405/554a5075b4c90531228b4a68/html5/thumbnails/20.jpg)
COAL AND ASH CIRCUIT
The coal flow is as shown below:
Coal storage plant
Crushers Bunkers Mills Boiler
![Page 21: An Overview of Thermal Power Plant](https://reader030.vdocument.in/reader030/viewer/2022012405/554a5075b4c90531228b4a68/html5/thumbnails/21.jpg)
COAL HANDLING PLANT
WAGON TRIPPLER CONVEYOR BELT
CRUSHERS BALL MILLS
![Page 22: An Overview of Thermal Power Plant](https://reader030.vdocument.in/reader030/viewer/2022012405/554a5075b4c90531228b4a68/html5/thumbnails/22.jpg)
ASH HANDLING PLANT
At the bottom of the furnace, there is a hopper for collection of bottom ash.
Fly ash is captured and removed from the flue gas by electrostatic precipitators.
The flow of ash is as shown belowBoiler Air pre
Heater ESPAsh
handling plant
Ash pond
![Page 23: An Overview of Thermal Power Plant](https://reader030.vdocument.in/reader030/viewer/2022012405/554a5075b4c90531228b4a68/html5/thumbnails/23.jpg)
COOLING WATER CIRCUIT
![Page 24: An Overview of Thermal Power Plant](https://reader030.vdocument.in/reader030/viewer/2022012405/554a5075b4c90531228b4a68/html5/thumbnails/24.jpg)
WATER SUPPLY
Water requirement for the KTPS is provided from Kinnerasani Project.
The total water required for the station is 1, 50,000 tons per day.
![Page 25: An Overview of Thermal Power Plant](https://reader030.vdocument.in/reader030/viewer/2022012405/554a5075b4c90531228b4a68/html5/thumbnails/25.jpg)
Primary Fuel Supply:
KTPS is linked to Singareni Collieries Company limited (S.C.C.L.) for supply of coal from Manuguru, Yellandu and Rudrampur mines.
![Page 26: An Overview of Thermal Power Plant](https://reader030.vdocument.in/reader030/viewer/2022012405/554a5075b4c90531228b4a68/html5/thumbnails/26.jpg)
STEAM TURBINE
Steam turbine is a rotating machine which converts the heat energy of steam into mechanical energy.
![Page 27: An Overview of Thermal Power Plant](https://reader030.vdocument.in/reader030/viewer/2022012405/554a5075b4c90531228b4a68/html5/thumbnails/27.jpg)
• HP Turbine
• IP Turbine
• LP Turbine
HIGH PRESSURE TURBINE: In high pressure turbine steam is expanded to do
work. High pressure turbine having 25 reaction stages. Steam admitted at 540oc and pressure 150
kg/sq.cm.
Description of Steam Turbines
![Page 28: An Overview of Thermal Power Plant](https://reader030.vdocument.in/reader030/viewer/2022012405/554a5075b4c90531228b4a68/html5/thumbnails/28.jpg)
IP TURBINE: Exhaust steam from hp turbine, after passing
through re heater is admitted for second phase of expansion of steam.
IP turbine having 17 reaction stages.
LOW PRESSURE TURBINE: Exhaust steam from IP turbine admitted to lp
turbine for the last phase of expansion of steam. LP turbine having 8 reaction stages
TYPES OF TURBINES
![Page 29: An Overview of Thermal Power Plant](https://reader030.vdocument.in/reader030/viewer/2022012405/554a5075b4c90531228b4a68/html5/thumbnails/29.jpg)
The excitation system comprises of an exciter and automatic voltage regulator.
The duty of an exciter is to provide the necessary field current to the rotor winding of the alternator.
Brush less excitation is used in KTPS Vth stage.
Excitation system
![Page 30: An Overview of Thermal Power Plant](https://reader030.vdocument.in/reader030/viewer/2022012405/554a5075b4c90531228b4a68/html5/thumbnails/30.jpg)
BRUSHLESS EXCITATION SYSTEM:
![Page 31: An Overview of Thermal Power Plant](https://reader030.vdocument.in/reader030/viewer/2022012405/554a5075b4c90531228b4a68/html5/thumbnails/31.jpg)
The excitation system comprises of an exciter and automatic voltage regulator.
The duty of an exciter is to provide the necessary field current to the rotor winding of the alternator.
Brush less excitation is used in KTPS Vth stage.
Excitation system
![Page 32: An Overview of Thermal Power Plant](https://reader030.vdocument.in/reader030/viewer/2022012405/554a5075b4c90531228b4a68/html5/thumbnails/32.jpg)
TOTAL INSTALLED CAPACITY:
1) KTPS-A Station : 4*60 = 240 MW
2) KTPS-B Station : 2*120 = 240 MW
3) KTPS-C Station : 2*120 = 240 MW
4) KTPS-V Stage : 2*250 = 500 MW
5) KTPS-VI Stage : 1*500=500 MW
Total installed capacity = 1720 MW
SALIENT FEATUREs OF K.T.P.S
![Page 33: An Overview of Thermal Power Plant](https://reader030.vdocument.in/reader030/viewer/2022012405/554a5075b4c90531228b4a68/html5/thumbnails/33.jpg)
CONCLUSION
In a modern thermal power plant the Rankine Cycle is modified to include superheating of steam, regenerative feed water heating and reheating of the steam.
Reheating the steam after it has partially expanded, improves the thermal cycle efficiency by 4 to 5%.Regenerative feed water heating by using Low pressure and High pressure heaters also improves the thermal cycle efficiency by 6 to 7%.
So the overall efficiency of a modern thermal power plant is about 42%.
![Page 34: An Overview of Thermal Power Plant](https://reader030.vdocument.in/reader030/viewer/2022012405/554a5075b4c90531228b4a68/html5/thumbnails/34.jpg)
![Page 35: An Overview of Thermal Power Plant](https://reader030.vdocument.in/reader030/viewer/2022012405/554a5075b4c90531228b4a68/html5/thumbnails/35.jpg)
THANK YOU!