Experimental test of instability enhanced collisional friction for
determining ion loss in two ion species plasmas
Noah Hershkowitz University of Wisconsin – Madison
Annual Meeting of APSNov. 8, 2010 Chicago, IL 1
With one ion species, ion drift velocity vd at the sheath plasma boundary is the Bohm velocity
• The Bohm velocity also is the ion sound velocity in the bulk plasma
• Ions are accelerated to the sheath boundary by presheath electric fields
• For one ion species, Riemann has shown the presheath potential
where is the ion-neutral collision length
vd cs
eTe
x
Background
cs Temi
2
•With 2 or more ion species, Riemann showed that ions satisfy a generalized Bohm criterion
•With only 2 ion species and assuming the equality holds
The generalized Bohm velocity may be satisfied by speeds faster or slower than the sound speed for a given ion species Two simple solutions: (1) all ions attain the same speed at the sheath edge(2) each species attains its own Bohm speed.
Solution (1) gives a common ion drift velocity at the sheath edge equal to the ion acoustic speed in a homogeneous plasma with no ion drifts.
•
ninei
csi
2
v i2 1
n1
ne
cs12
v12 n2
ne
cs22
v22 1
Many authors quite naturally have assumed that solution (2) applies.
If the plasma is collisionless, then all ions can reach their individual Bohm velocity at the sheath edge by falling through a potential of Te/2.
In weakly collisional plasmas, ion motion is mobility limited and much larger potential drops are required to reach the Bohm velocity. Under these conditions, the potential drop that works for one ion species does not work for the other ion species.
4
Our recent experiments have shown that ions in weakly collisional plasmas containing two ion species of comparable densities nearly reach a common velocity at the sheath edge within errors
The common velocity was the bulk system ion sound velocity
How does the plasma achieve that result?
Ar+Xe LIF & emissive probe data show the difference in flow Ar+Xe LIF & emissive probe data show the difference in flow speeds throughout the presheath is smallspeeds throughout the presheath is small
- Ar 0.5 + Xe 0.2 mTorr- Filament: -60 V, 1.25 A- Electrode: -30 V- ne = 5.71×109 cm-3, Teff = 0.68 eV
- Cs(Ar) = 1280 m/s, Cs(Xe) = 710 m/s- Sheath edge from EP = 0.25 ~ 0.30 cm- Phase velocity by IAW: 1090 ± 40 m/s- Ion ratios: Ar 0.61 + Xe 0.39
Ar ion speed with respect to z in Ar+Xe plasma- At the sheath edge: <vrms> = 1080 ± 50 m/s- The Ar velocity measured from the LIF data at the sheath edge is between the Bohm velocity of argon and xenon.- The results show that the argon ions also get close to the sound speed of the system at the sheath boundary when the argon is the lighter species.
6
An Ion-Ion beam Instability is observedAn Ion-Ion beam Instability is observed
7
Baalrud et al.1,2 have recently argued that ion beam - ion beam instability-enhanced collisional friction establishes the solution of the Bohm Criterion
The relative flow speed of the two ion species with large differences in ion masses was predicted to be limited to a value determined by the instability-enhanced friction, the thermal velocities and relative densities of the ions and their mass differences.
In particular, they predict that individual species’ velocities equal individual species’ Bohm velocities when one species’ density was much larger than the other, and a minimum velocity difference when the ion concentrations are comparable. The predicted velocity diffeence goes to zero as Ti goes to zeero.
[1] S. Baalrud, J. Callen, and C. Hegna, Phys. Rev. Lett. 103, 205002 (2009)[2] S. Baalrud, and C. Hegna, UW-CPTC 10-2 (Dated: April 7, 2010)
Experimental Approach• Plasma is produced in a multi-dipole device by energetic electrons emitted from heated filaments.
• The concentration ratio of the two ion species is determined from the phase velocity of Ion Acoustic Waves in the bulk plasma combined with the measured Te
• Electron temperature is measured with a Langmuir probe.
• Laser Induced Fluorescence determines ion flow velocities and ion temperatures. Both Ar+ and Xe+ LIF are employed
• An emissive probe measures the plasma potential profile near a negatively biased plate
• The sheath/presheath boundary is identified from the slope change of the emission current vs bias voltage curve
• Drift velocities of both species at the sheath edge are compared with the solution to the generalized Bohm criterion predicted by the theory.
• A Maxwell demon wire array device is used to heat the plasma for temperature variance
9
Multi-dipole device
Pump
ProbeCircuitEmissive Probe
Langmuir Probe
Electrode Plate
-60 V, 1.0A
Hot Filament
-30 V
PMT
Z
LIF
Laser
Magnets
ee
e
70 cm
60 cm
Beam Dump
10
Experimental setup of the laser systemExperimental setup of the laser system
OpticalChopper
WavelengthMeter
ChopperController
I2 Cell
PowerMeter
Mirror
Mirror
Periscope
HeatingRibbon
Laser Head
Laser Driver
I2 CellHeater
To Chamber
11
Multi-dipole Device
Ar LIF
Laser
PMT
EP
- Argon or Helium + Xenon - Gas pressure: 0.1 ~ 1.0 mTorr- Filament bias: -60 V- Emission current: 1.0 ~ 1.25 A- Electron density: ~ 109 cm-3
- Electron temperature: ~ 1 eV- Using the filament of the emissive probe as an aiming point of the laser.
12
How does the LIF work?How does the LIF work?
Optical excitation of Ar metastable ion in state 3d4F7/2 to 4p4D5/2 with the diode laser of 668.614 nm
Relaxation from the state 4p4D5/2 to 4s4P3/2. Observe the fluorescence at 442.72 nm
In Xe excite with 680.574 nm and observe fluorescence at 492.15 nm
It is assumed that the metastable ions are in thermal equilibrium with ground state ions 13
The sheath edge is determined from the change The sheath edge is determined from the change in slope of inflection point vs Vin slope of inflection point vs Vpp
2
0 2 ( )i ed e n ndx
Plasma parameters- Ar 0.7 mTorr- Filament: -60 V, 1.00 A- Electrode: -30 V
Where is the sheath edge?- Emitted electrons from the probe reduces the curvature of potential.- The reduction in the curvature of the potential increases as the emission increases.- The inflection point becomes more positive with the increased emission in a sheath.- An electron-free sheath is identified as the position where the inflection point changes from increasing with emission to decreasing with emission.- From the figure, the sheath edge is determined to be 0.35 ~ 0.40 cm
14Wang X, Hershkowitz N. Simple way to determine thee edge of an electro-free sheath with an emissive probe, REVIEW OF SCIENTIFIC INSTRUMENTS 77, 4, 043507. 2006
15
•MacKenzie et al. successfully heated a plasma by an angular momentum trap of cold electrons with a 60 x 60 cm grid of 0.03mm tungsten wire in a 1-m diameter by 2-m long filament discharge chamber. [1]
•Mackenzie’s Maxwell demon wire array is revisited in a multi-dipole chamber filament discharge in a much simpler incarnation - loops of 0.025mm tungsten filament (about 3 meters in total length) spot-welded onto a conductive probe-shaft covered with electrical insulating material (ceramics and fiber-glass covers) to create an exposed wire-array, which works in spite of the lack of overall geometry.
A Maxwell demon wire array is used to raise A Maxwell demon wire array is used to raise the plasma temperature for investigationthe plasma temperature for investigation
16
Note that the plasma after its temperature is Note that the plasma after its temperature is raised satisfies the Bohm’s Criterionraised satisfies the Bohm’s Criterion
Te=0.89eV without demon by Langmuir Probe(Cs = 810.3 m/s)Te=1.71eV with demon by Langmuir Probe (Cs = 1120m/s)Measured IAW velocity = 1111±70m/sMeasured Ion velocity at sheathedge = 1094±70m/s
Ion velocity and potential profile of a Xenon plasma with its temperature doubled by the Maxwell demon.
IAW data tell the same story as LIF data. IAW data tell the same story as LIF data. Phase velocity at sheath edge Phase velocity at sheath edge 2v 2vbulkbulk
-Neutral Pressures: Argon 0.5mT Xenon 0.2mT- Bulk velocity ~ 1080m/s- Argon – Xenon Ratio ~ 47:53- Filament: -60 V, 1.25 A- Electrode: -30 V-Teff 0.75eV- Sheath edge from EP = 0.4± 0.05cm- Phase velocity by IAW: 1080± 70 m/s
17
For Argon-Xenon plasmas, ion temperatures at the sheath/presheath edge are comparable except for low relative ion concentrations
Ion temperatures are calculated by the equation Ti = mi(<v2>-<v>2)1/2/2
19
In a Xenon-Helium plasma, however, Xenon temperature rises both when Xenon dominates the plasma and when ion concentrations are comparable
The fractional Xenon ion concentration is much higher than its the fractional neutral concentrations for both Xenon-Argon and Xenon-Helium plasmas because of Penning ionization
21
Data shows that Ion-Ion Instability depends both on the relative flow velocity and the relative concentration of the two species.
This was verified in our paper, “Experimental Test of Instability-Enhanced Collisional Friction for Determining Ion Loss in Two Ion Species Plasmas”, Yip, CS; Hershkowitz, N; Severn, G. Phys Rev Lett. Vol.104 Iss:22 #225003 (2010)
When ion masses are comparable, the theory predicts
Xenon drift velocities measured by LIF are marked by the squares, Argon velocities measured by LIF are marked in circles, solid line is the prediction curve and the dash dotted line is the common sound velocity.
Ar
Xe
23
Xenon and Argon ion sheath velocities measured in Te = 1.80±0.05eV plasmas, notice that Argon velocities were implied by the generalized Bohm Criterion.
Measurements made at a higher temperature (Te = 1.8eV) achieved by the Maxwell demon also confirms the same results.
24
When ion masses are very different, the theory predicts
Vc 12
vT12 vT 2
2
where and vTj are the ion thermal velocities
n1m2
n2m1
Our Xenon-Helium drift velocities data: Xenon drift velocities measured by LIF are marked by the squares, Helium velocities infered by Generalized Bohm’s Criterion are marked in circles, dashed line is the prediction curve and the dash dotted line is the common sound velocity.
Xe
He
Conclusions
• The generalized Bohm criterion has been verified for Ar-Xe plasmas
• LIF data are in excellent agreement with the theory based on ion beam - ion beam instability-enhanced collisional friction for weakly collisional Ar-Xe and He-Xe plasmas
• Experiments with Maxwell’s Demon increased Te are also in excellent agreement with collisional friction theory.
• Ions do not fall out of plasmas with their individual Bohm velocities except when their relative concentrations are either very large or very small
26
This work was supported by U.S. Department of Energy Grants No. DE-FG02-97ER54437 and No. DE FG02- 03ER54728, National Science Foundation Grants No. CBET-0903832, and No. CBET-0903783
Acknowledgements:
My Collaborators
Chi-Shung Yip, University of Wisconsin – Madison and
Greg Severn, University of San Diego
• They predict that individual species’ velocities equal individual species’ Bohm velocities when one species’ density was much larger than the other.
• This experiment is an attempt to verify the collisional friction theory by measuring the ivdfs and other related plasma parameters in a multi-dipole chamber operating with discharges of Argon and Xenon or Argon and Helium with varying concentration ratios.
27