ANALYTICAL REPORTEurofins TestAmerica, Cedar Falls3019 Venture WayCedar Falls, IA 50613Tel: (319)277-2401
Laboratory Job ID: 310-178508-1Client Project/Site: Brian Wilson
For:Iowa Department of AgricultureMines and Minerals Bureau502 E. 9th StDes Moines, Iowa 50319
Attn: Ryan Starkey
Authorized for release by:3/31/2020 11:04:01 AMAngela Muehling, Project Manager II(319)[email protected]
Designee for
Shirley Thompson, Senior Project Manager(319)[email protected]
This report has been electronically signed and authorized by the signatory. Electronic signature isintended to be the legally binding equivalent of a traditionally handwritten signature.
Results relate only to the items tested and the sample(s) as received by the laboratory.
1
2
3
4
5
6
7
Case NarrativeClient: Iowa Department of Agriculture Job ID: 310-178508-1Project/Site: Brian Wilson
Job ID: 310-178508-1
Laboratory: Eurofins TestAmerica, Cedar Falls
Narrative
Job Narrative310-178508-1
Comments
No additional comments.
Receipt
The samples were received on 3/27/2020 5:45 PM; the samples arrived in good condition, properly preserved and, where required, on ice.
The temperature of the cooler at receipt was 3.2º C.
Metals No analytical or quality issues were noted, other than those described in the Definitions/Glossary page.
General Chemistry No analytical or quality issues were noted, other than those described in the Definitions/Glossary page.
Eurofins TestAmerica, Cedar FallsPage 2 of 9 3/31/2020
1
2
3
4
5
6
7
Sample SummaryJob ID: 310-178508-1Client: Iowa Department of Agriculture
Project/Site: Brian Wilson
Lab Sample ID Client Sample ID ReceivedCollectedMatrix Asset ID
310-178508-1 Pond 2 Ground Water 03/26/20 10:20 03/27/20 17:45
310-178508-2 Pond 3 Ground Water 03/26/20 11:05 03/27/20 17:45
Eurofins TestAmerica, Cedar Falls
Page 3 of 9 3/31/2020
1
2
3
4
5
6
7
Client Sample ResultsJob ID: 310-178508-1Client: Iowa Department of Agriculture
Project/Site: Brian Wilson
Lab Sample ID: 310-178508-1Client Sample ID: Pond 2Matrix: Ground WaterDate Collected: 03/26/20 10:20
Date Received: 03/27/20 17:45
Method: 200.7 Rev 4.4 - Metals (ICP)RL MDL
Iron <0.500 0.500 mg/L 03/30/20 17:44 1
Analyte Dil FacAnalyzedUnit DResult Qualifier Analyst
CTB
General ChemistryRL RL
pH 7.4 HF 0.1 SU 03/27/20 20:55 1
Analyte Dil FacAnalyzedUnit DResult Qualifier Analyst
JMH
Lab Sample ID: 310-178508-2Client Sample ID: Pond 3Matrix: Ground WaterDate Collected: 03/26/20 11:05
Date Received: 03/27/20 17:45
Method: 200.7 Rev 4.4 - Metals (ICP)RL MDL
Iron 1.08 0.500 mg/L 03/30/20 17:46 1
Analyte Dil FacAnalyzedUnit DResult Qualifier Analyst
CTB
General ChemistryRL RL
pH 7.3 HF 0.1 SU 03/27/20 20:56 1
Analyte Dil FacAnalyzedUnit DResult Qualifier Analyst
JMH
Eurofins TestAmerica, Cedar Falls
Page 4 of 9 3/31/2020
1
2
3
4
5
6
7
Accreditation/Certification and Definitions SummaryClient: Iowa Department of Agriculture Job ID: 310-178508-1
Project/Site: Brian Wilson
Laboratory: Eurofins TestAmerica, Cedar FallsThe accreditations/certifications listed below are applicable to this report.
Authority Program Identification Number Expiration Date
Iowa 007State 12-01-19 *
Qualifiers
General Chemistry
Qualifier Description
HF Field parameter with a holding time of 15 minutes. Test performed by laboratory at client's request.
Qualifier
Glossary
These commonly used abbreviations may or may not be present in this report.
¤ Listed under the "D" column to designate that the result is reported on a dry weight basis
Abbreviation
%R Percent Recovery
1C Result is from the primary column on a dual-column method.
2C Result is from the confirmation column on a dual-column method.
CFL Contains Free Liquid
CNF Contains No Free Liquid
DER Duplicate Error Ratio (normalized absolute difference)
Dil Fac Dilution Factor
DL Detection Limit (DoD/DOE)
DL, RA, RE, IN Indicates a Dilution, Re-analysis, Re-extraction, or additional Initial metals/anion analysis of the sample
DLC Decision Level Concentration (Radiochemistry)
EDL Estimated Detection Limit (Dioxin)
LOD Limit of Detection (DoD/DOE)
LOQ Limit of Quantitation (DoD/DOE)
MDA Minimum Detectable Activity (Radiochemistry)
MDC Minimum Detectable Concentration (Radiochemistry)
MDL Method Detection Limit
ML Minimum Level (Dioxin)
NC Not Calculated
ND Not Detected at the reporting limit (or MDL or EDL if shown)
PQL Practical Quantitation Limit
QC Quality Control
RER Relative Error Ratio (Radiochemistry)
RL Reporting Limit or Requested Limit (Radiochemistry)
RPD Relative Percent Difference, a measure of the relative difference between two points
TEF Toxicity Equivalent Factor (Dioxin)
TEQ Toxicity Equivalent Quotient (Dioxin)
Eurofins TestAmerica, Cedar Falls
* Accreditation/Certification renewal pending - accreditation/certification considered valid.
Page 5 of 9 3/31/2020
1
2
3
4
5
6
7
Method SummaryJob ID: 310-178508-1Client: Iowa Department of Agriculture
Project/Site: Brian Wilson
Method Method Description LaboratoryProtocol
40CFR136A200.7 Rev 4.4 Metals (ICP) TAL CF
SMSM 4500 H+ B pH TAL CF
EPA200.7 Preparation, Total Metals TAL CF
Protocol References:
40CFR136A = "Methods for Organic Chemical Analysis of Municipal Industrial Wastewater", 40CFR, Part 136, Appendix A, October 26, 1984 and
subsequent revisions.
EPA = US Environmental Protection Agency
SM = "Standard Methods For The Examination Of Water And Wastewater"
Laboratory References:
TAL CF = Eurofins TestAmerica, Cedar Falls, 3019 Venture Way, Cedar Falls, IA 50613, TEL (319)277-2401
Eurofins TestAmerica, Cedar Falls
Page 6 of 9 3/31/2020
1
2
3
4
5
6
7