Download - Axial Flow Machines
![Page 1: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/1.jpg)
1
AXIAL-FLOW MACHINES further concepts Euler Turbine Equations Axial Flow Gas Turbines Axial Flow Compressors Losses / Zweifel Free-Vortex Flow Blade Stresses Re: Peng Ch. #8 & #7
![Page 2: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/2.jpg)
2
Axial Turbine Cascade Stator
Rotor
Stator
![Page 3: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/3.jpg)
3
TURBINE STAGE STATOR STAGE V1 W1 U ROTOR V2 W2 STATOR
![Page 4: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/4.jpg)
4
AXIAL TURBINE
W2 V1 V2 W1
100 percent reaction 0
U stator rotor
![Page 5: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/5.jpg)
5
TURBINE STAGE FLOW ANGLE TERMINOLOGY
ALPHA (α) ~ STATOR ANGLES BETA (β) ~ ROTOR ANGLES STATOR V1 W1 U ROTOR V2 W2 STATOR
Watch out for notation!
AXIAL DIRECTION
0o
Negative Positive Angle Angle
![Page 6: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/6.jpg)
6
Euler Turbine Equation(s) Torque
T = m ( VU1 r1 – VU2 r2) / gc Power W = m ( VU1U1 – VU2U2) / gc Energy per unit mass ΔE = W / m = ( VU1U1 – VU2U2 ) /gc
ΔE = Δh = change in specific enthalpy
![Page 7: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/7.jpg)
7
Right end: ‘free wheeling’ , runaway condition.
No torque on rotor….no power …no use. Left end: Lots of torque but rotor velocity goes to zero. Since power = torque x angular velocity = 0
![Page 8: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/8.jpg)
8
Parsons Turbines (RN = 50% )
each with φ = ½ V2 W2 V1 W1 U W2 V1 V2 W1 U
![Page 9: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/9.jpg)
9
MAXIMUM UTILIZATION Work per unit mass = W / m = U (VU1 - VU2 ) For maximum work per unit mass: VU2 = 0 i.e. V2 is in axial direction only
![Page 10: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/10.jpg)
10
MAXIMUM UTILIZATION
Work per unit mass = W / m = U (VU1 - VU2 ) W2 V1 W1 V2 = Vx U S R
![Page 11: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/11.jpg)
11
α V2 W2 V1 W1 U
MAXIMUM UTILIZATION AXIAL TURBINE (W/m) = 2U2 / gc V2 = Vx = Va = axial direction
cos α = 2U / V1
![Page 12: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/12.jpg)
12
EXAMPLE An axial-flow turbine has a mean diameter of 40 cm and a flow coefficient (φ = Va/U) of one-half. Flow enters the stator in the axial direction with a velocity of 50 m/s and exits the stator with a nozzle angle (α, measured between V1 and U) of 17 degrees. The fluid flows through the stage with constant axial velocity and produces an output torque of 1600 Nm.
a) Sketch the velocity vector diagram for this stage. b) Calculate the power output of the turbine stage.
c) What is the degree of reaction?
![Page 13: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/13.jpg)
13
V2 = 50 W2 V1 W1
α = 17o
U
![Page 14: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/14.jpg)
14
SOLVING FOR VELOCITY VECTORS: Φ= Va/U = ½ U = 100 m/s VU1 = 50 tan 73o = 164 m/s VU1 = 164 m/s WU1 = VU1 – U V1 = 171 m/s VU2 = 0 WU2 = U = 100 m/s W2 = 112 m/s W1 = 80.85 m/s EULER EQNS: Torque = m (VU1 R1 – VU2R2) m = 1600 / (164)(0.2) = 49 kg/s Power = m (VU1U1 – VU2U2) = (49)(164)(100) = 800 kW DEGREE OF REACTION: VU1 + VU2 R = 1 – = 1 – (163 + 0) / 2(100) = 0.28 = 28% 2U
![Page 15: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/15.jpg)
15
COMPRESSOR STAGE STATOR STAGE V1 W1 U ROTOR W2 V2 STATOR V1
![Page 16: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/16.jpg)
16
AXIAL COMPRESSOR
V1 V2 W1 W2
100 percent reaction 0
U stator rotor ~50% reaction, not a great design
![Page 17: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/17.jpg)
17
High Reaction Axial Compressor
V1 V2 W1 W2
100 percent reaction 0
U stator rotor
![Page 18: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/18.jpg)
18
Low reaction axial compressor
V2 W2
V1 V2 W1 W2
100 percent reaction 0
U stator rotor
![Page 19: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/19.jpg)
19
Turbine and Compressor Performance Unrecoverable Pressure Losses Allied Signal ASE120 Gas Turbine Engine Phoenix, AZ Designed for cogeneration, emergency power and mechanical drive. ~35% thermal efficiency ~10 MW m-dot~34kg/s Texhaust ~500oC Weight ~ 5,000 lb NOx ~ 10-25 ppm
![Page 20: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/20.jpg)
20
(NOT RELATED TO UNRECOVERABLE PRESSURE LOSSES LECTURE) ASE120 engine performance as a function of inlet air temperature Notice that maximum output power decreases about 50% when the air let increases from ~ -20C to +50C (~16,000hp to 8,000 hp)
Ou
tpu
t P
ow
er
(h
p)
-20 Inlet Air Temperature (oC) 50
Power
16,000
8,000
![Page 21: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/21.jpg)
21
Unrecoverable Pressure Losses
Profile drag (and fluid friction) across blades
Annular skin friction
Secondary drag / losses
Tip leakage
Seal leakage
![Page 22: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/22.jpg)
22
IDEAL TURBINE V2 V1 W2 W1 U S R
![Page 23: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/23.jpg)
23
∆CU Actual performance is always less than the ideal theoretical performance due to un-recoverable losses
IDEAL
ACTUAL
![Page 24: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/24.jpg)
24
Turbine Performance: Turbine Flow ~ Nozzle Flow Turbine performance follows the general behavior of ideal flow through a nozzle…Tot max delP ~ den x sq vel (Eqn W 2.12) Incompressible flow, conservation of energy-ss, no change in PE ∆P = Po – Pst = total – static = dynamic pressure Don’t forget gc when using USCS units. Notice the total maximum pressure drop ~ density x velocity2 Mass flow ~ flow area x rho x delP CD ~ discharge coefficient: correction coefficient for ‘real fluids’ with viscosity, friction losses. Usually empirically based, rooted in experiment.
∆P = ½ρC2 / gc
m = A 2ρ∆Pgc ½ CD
“discharge coefficient”
CD = ∑CD
![Page 25: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/25.jpg)
25
PROFILE DRAG ACROSS BLADES In addition to classic profile / skin friction drag….. VIBRATIONS: fluttering / vortex shedding
esp. problem w/ thin blades…fans, some compressors
2FD CD = ρV2A
![Page 26: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/26.jpg)
26
Flow Separation over Compressor Rotor Blades FLOW High Reaction Low Reaction (no separation) (separated flow)
Separation leads to COMPRESSOR LOSSES STALL …losses in efficiency. Separation leads to losses in pressure, enthalpy It is very complicated to accurately predict the conditions in which B.L separation occurs. Therefore, empirically-based ‘rules-of-thumb’ have been developed. As we’ll see, flow separation can be minimized with a ‘cascade’ of blades…..i.e. form flow passages
![Page 27: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/27.jpg)
27
ANNULAR SKIN FRICTION LOSS s = spacing Due to boundary layer formation within the annular flow passage. Empirical correlation.
h
CD’ ~ 0.02 (s/h)
![Page 28: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/28.jpg)
28
SECONDARY DRAG / LOSSES End wall boundary layers are convected inward along the suction side of the blades. Secondary currents are set up in a plane transverse to the flow, dissipating energy. Results in un-favorable flow redistribution, competing vortices, and loss in stagnation pressure. Can be a significant fraction of total P-loss. These currents also take place in the wake regions down stream from the trailing edges of the blades.
![Page 29: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/29.jpg)
29
Secondary Flow in Blade Passages
The constant 0.018 stems from a complex relationship between flow acceleration, aspect ratio (h/c), spacing & pitch. RE: Logan Ch 6 Because the trailing vortices are similar to wing vortices, it is expected that the corresponding drag is proportional to the LIFT COEFFICIENT CL.
CD” = 0.018CL2
![Page 30: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/30.jpg)
30
Wilson Text Effect of aspect ratio (h/c or h/b) on secondary losses.
![Page 31: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/31.jpg)
31
TIP LEAKAGE
TIP LEAKAGE
CD”’ = 0.29 (k/h)CL3/2
The difference in pressure on the two sides of the moving blades results in leakage around the tip. Shroud reduces leakage ~50% k=clearance gap = f(T, rpm, loading) h= blade length CL=lift coefficient
![Page 32: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/32.jpg)
32
![Page 33: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/33.jpg)
33
LOSSES FROM SEALS Pressure changes across casing boundaries are another source of losses. Each place where the rotor penetrates a pressure boundary needs a seal. Typically LABYRINTH SEALS.
GENERATOR LPT1 LPT2 HPT
![Page 34: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/34.jpg)
34
LABYRINTH SEALS
![Page 35: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/35.jpg)
35
![Page 36: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/36.jpg)
36
LABYRINTH SEALS
CD”” = f(∆P, h, ρ, D, ….)
![Page 37: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/37.jpg)
37
Clearances change with thermal expansion, radial stresses, axial stresses, fluid loadings, rotor flex, rotor unbalance, startup/shutdown transients,…. Rotor alignment is critical for rotor seals.
![Page 38: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/38.jpg)
38
UNRECOVERABLE PRESSURE LOSSES (PROFILE, SKIN FRICTION & SECONDARY)
COMPRESSORS, PUMPS & FANS
ΔP stage = ρ U2 φ ψ χ ηstage = ΔPactual / ΔPideal = φχ χ = (R - φδ) / (φ+ δR) + (1 – R - φδ) / (φ + δ(1 – R)) rotor stator φ = flow coefficient = Cx / U ψ = blade loading coefficient = ΔCu / U R =degree of reaction δ = drag to lift ratio U = rotor velocity ΔP = pressure gain
LOGAN P115
![Page 39: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/39.jpg)
39
δ = drag to lift ratio = ∑CD / CL = (CD + CD’ + CD” + CD”’ + CD””) / CL
![Page 40: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/40.jpg)
40
EXAMPLE: Axial compressor with Rn=50% and the velocity vectors shown. The lift and drag coefficients are the same for the rotor and stator and are 1.4 and 0.1, respectively. CD includes all losses. Calculate the stage pressure rise and required energy input if the entering air has a density of 1.2 kg/m3. Each square corresponds to 50 m/s x 50 m/s 50 m/s V1 V2 W1 W2 U stator rotor
![Page 41: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/41.jpg)
41
EXAMPLE (con’t)
ΔP stage = ρ U2 φ ψ χ = ΔPactual U = 300 m/s Vx = 150 m/s VU1 = 50 m/s VU2 = 250 m/s
ψ = (VU1 – VU2)/U = (50-250)/300 = -2/3 (neg=compressor)
φ = Vx/U = 150/300 = 1/2
δ = drag/lift = 0.1/1.4 = 0.071
χ = (R - φδ) / (φ+ δR) + (1 – R - φδ) / (φ + δ(1 – R))
χ = (0.5-0.5x0.071)/(0.5 + 0.071x0.5) + (1-0.5-0.5x0.071)/ (0.5+0.071(1-0.5))
χ = (0.46/0.54) + (0.46/0.54) = 1.7
![Page 42: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/42.jpg)
42
EXAMPLE (con’t)
ΔP stage = ρ U2 φ ψ χ= ΔPactual ΔPactual = (1.2)(300)2 (0.5) (0.66)(1.7) = 60.6 kN/m2
= 60.6 kPa
ηstage = ΔPactual / ΔPideal = φχ = (0.5)(1.7) = 0.85 ΔPactual / ΔPideal = 0.85 = 60.6 kPa/ΔPideal
ΔPideal = 71.3 kPa
Energy per unit mass (Euler Turbine Equation) [W /m]ideal = ( Vu1U1 - Vu2U2 ) / gc
=(300)m/s [50-250]m/s = -60 kJ/kg
[W /m]actual = [W /m]ideal / ηstage = (-60)/(0.85) = -70 kJ/kg
![Page 43: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/43.jpg)
43
FLOW SEPARATION
de Haller Number: dH
dH = Wexit / Win = W2 / W1
dH > 0.72 No Separation Swiss engineer Established criterion for flow separation in compressor cascades (for compressor cascades, RE: Wilson, Ch#4 p.182) But…also sometimes applied to turbine blades as well using V1 & V2
![Page 44: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/44.jpg)
44
De Haller: dH = Wexit / Win > 0.72 no separation dH = W2 / W1 COMPRESSOR V1 V2 W1 W2
U S R
![Page 45: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/45.jpg)
45
De Haller: dH = Wexit / Win > 0.72 no separation dH = W2 / W1 COMPRESSOR V1 V2 W1 W2
U S R Increase W2, Increase dH, decrease potential for separation?
![Page 46: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/46.jpg)
46
Pressure Rise Coefficient (compressor cascade)
Cpr = (Pst,ex – Pst,in)/(Po,in – Pst,in) = rise in static pressure / inlet dynamic pressure
For an ideal compressor Cpr = 1 – (Wex / Win)2
Cpr < 0.5 Consider each stage of a compressor as a compressor The pressure rise at each stage can only increase so much, Limits on pressure rise Cpr ~< 0.5
VELOCITY VECTORS SUMMARY
![Page 47: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/47.jpg)
47
Axial Flow Compressor and Turbine
![Page 48: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/48.jpg)
48
DEGREE OF REACTION
Vu2 Vu1 Rn = ∆hrotor / ∆hstage = (h2 – h3) / (h1 – h3) = ∆Protor / ∆Pstage V2 V1 W2 W1 = (P2 – P3) / (P1 – P3) = 1 – (Vu1 + Vu2) / 2U
(Text eqn 5.8)
![Page 49: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/49.jpg)
49
Zweifel’s Correlation OPTIMUM SOLIDITY
Axial Turbine Cascade Stator
Rotor
Stator
![Page 50: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/50.jpg)
50
Lift and Drag Forces
FL = CL (ρAV2) / 2gc
FD = CD (ρAV2) / 2gc Comments on LIFT and DRAG forces: Lift and drag forces are difficult to model exactly due to complex flow phenomena including: viscous effects, boundary layer separation, etc. Hence, ‘empirically determined correction coefficient’ is typically used. CL and CD are lift and drag coefficients, usually determined empirically. CD typically accounts for both pressure and skin friction drag. ‘A’ is some characteristic area. ‘V’ is some representative velocity: free stream, average or mean velocity, etc.
![Page 51: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/51.jpg)
51
Isolated Flat Plate
Cascade of Blades
S C K=cascade coefficient = f(beta, s/c) S= pitch or spacing C = chord
β CL = 2πsinβ
CLcas=K(CL)
![Page 52: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/52.jpg)
52
![Page 53: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/53.jpg)
53
BLADE SPACING / SOLIDITY (σ = c / s) Is there an option spacing?
Low solidity High solidity Losses by separation ~No separation Losses by skin friction s = pitch or spacing c = chord
s
c
![Page 54: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/54.jpg)
54
![Page 55: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/55.jpg)
55
![Page 56: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/56.jpg)
56
β1
β2 NOTE ERROR IN PENG’S TEXT: PAGE 227
CL = 2(s/b)cos2β2(tan β1 - tan β2) σ = c/s = solidity Wilson 7.4
![Page 57: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/57.jpg)
57
Zweifel (Peng Text, Ch 8 p 227) (Brown Boveri, Swiss, 1945)
CL,op ~ 0.8
![Page 58: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/58.jpg)
58
α = - 30o
β = + 60o
EXAMPLE The spacing (pitch) between turbine or compressor blades influences the machine’s performance.
Shown below is a cascade of blades for an axial compressor. Flow in U c = 12 cm b = 10 cm Flow out
(a) Determine the optimum blade spacing, s = ?
Optimum Spacing
Zweifel Correlation
(b/s) opt = |(2/CL,opt) cos2αex [tanαin – tan αex]| = |(2/0.8) cos 2 (60o) [tan (-30o) – tan (60o)]| = 1.44 thus, s = b/1.44 = 6.94 cm
![Page 59: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/59.jpg)
59
AXIAL TURBINES NUMBER OF BLADES Wind: 1-24 Water: 3-30 Gas / Steam: 11-110 Rotors usually have an even number of blades (for balance) Stators usually have an odd number of blades (for vibration)
![Page 60: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/60.jpg)
60
VORTEX FLOW Radial Equilibrium A tornado is nature’s efficient vortex flow. Characteristic of air / gas at higher velocities (200+ mph ~ 300 ft/s ~ 100 m/s) It pumps air from the higher pressure ground to overhead cloud. We can capture that flow characteristic in the design of axial compressor (and turbine) blade design that encourage free vortex flow.
UF6 Axial Compressor
Tornado
![Page 61: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/61.jpg)
61
Velocity Distribution in a Tornado
R = “eye” of tornado
R
Forced Vortex (rotational) r < R Vu = ωr
Vurn = constant
Free Vortex (irrotational) r > R Vu = ωR2/r
Vur = constant
![Page 62: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/62.jpg)
62
![Page 63: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/63.jpg)
63
Pressure Distribution in a tornado Patm
R -P Minimum pressure is in center of eye. The entire field pressure is sub-atmospheric pressure (AKA Under-pressure)
![Page 64: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/64.jpg)
64
Uniform Circular Motion r
Fc v θ
F = ma
Fc = mac = mv2/r Fc = centripetal force (in +) ac = centripetal acceleration v = tangential speed = vu
θ = angular position (rad) ω = angular velocity (rad/s) ac = centripetal acceleration (m/s2) 2∏ radians ω = dθ/dt =
time for one revolution 2∏ =
2∏r/v
= v/r
ac = d2θ/dt2 = v2/r
![Page 65: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/65.jpg)
65
Radial Pressure Forces on Fluid Element (F=PA) P + dP P + ½ dP P + ½dP P dr r dθ Fc For Radial Equilibrium: The radial components of the pressure forces (F=PA) must be balanced by the centrifugal force on the fluid mass.
![Page 66: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/66.jpg)
66
For Radial Equilibrium
∑Fradial = Fc + ∑FP =0
Free-Vortex Flow: Vur = constant
![Page 67: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/67.jpg)
67
TIP
HUB
![Page 68: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/68.jpg)
68
TIP Vu1 HUB
Constant axial velocity Axial V2 = maximum utilization Cur = const r∆Vu = const
Don’t want hub to fall below 0% rxn
![Page 69: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/69.jpg)
69
![Page 70: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/70.jpg)
70
TIP (RXN) HUB (IMP)
![Page 71: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/71.jpg)
71
Station A is entry to nozzle / stator Station B is entry to blade / rotor Station C is exit from blade Nozzle blade is twisted to give overall free vortex flow. The Blade is straight. Nozzle sets up flow in radial decreasing velocity profile….upon passage over uniform rotor blade, re-establishes uniform vel profile. Illustrates other losses: Wall friction losses (skin friction) and tip-clearance leakage (PsB > PsC)
![Page 72: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/72.jpg)
72
Euler Turbine Equation(s) Torque
T = m ( Vu1 r1 - Vu2 r2) / gc Power W = m ( Vu1U1 - Vu2U2) / gc Energy per unit mass W / m = ( Vu1U1 - Vu2U2 ) / gc
![Page 73: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/73.jpg)
73
TURBINE V2 V1 W2 W1 U S R W ~ Vu1U1 - Vu2U2 V2 V1 W2 W1
![Page 74: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/74.jpg)
74
FORCES & STRESS ON BLADES
“frozen” isochromatic fringes on three-dimensional photoelastic model of gas turbine blade hub.
![Page 75: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/75.jpg)
75
Forces acting on turbine & compressor blades
Fluid forces: Lift & Drag
Centrifugal forces Thermal forces / stresses Fluid forces: Lift & Drag Of special interest are the tangential components of the lift and drag forces
since these forces directly affect the power and efficiency. Produce bending forces / stresses due to changes in fluid pressure and momentum. Total Drag force = pressure drag (form drag, shape drag) + Viscous Drag (viscous drag) Due to complex flows, losses occur. Excitation and vibrations may result from fluctuating pressure gradients. Centrifugal forces Produces radial & bending stresses
(bending when centroids of all cross sections do not lie along a radial line) Limits the design length and rpm Easiest force to model Thermal forces / stresses When its not at a uniform temperature, thermal stresses arise.
![Page 76: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/76.jpg)
76
Lift and Drag Forces RADIAL LIFT AXIAL DRAG V1 Vm V2
![Page 77: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/77.jpg)
77
Lift and Drag Forces FL = CL (ρAV2) / 2gc FD = CD (ρAV2) / 2gc Comments on LIFT and DRAG forces: Lift and drag forces are difficult to model exactly due to complex flow phenomena including: viscous effects, boundary layer separation, etc. Hence, ‘empirically determined correction coefficient’ is typically used. CL and CD are lift and drag coefficients, usually determined empirically. CD typically accounts for both pressure and skin friction drag. ‘A’ is some characteristic area. ‘V’ is some representative velocity: free stream, average or mean velocity, etc.
![Page 78: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/78.jpg)
78
Isolated Flat Plate
Cascade of Blades
S C K=cascade coefficient = f(beta, s/c) S= pitch or spacing C = chord
β CL = 2πsinβ
CLcas=K(CL)
![Page 79: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/79.jpg)
79
![Page 80: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/80.jpg)
80
![Page 81: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/81.jpg)
81
Fluid Forces: Vibration & Excitation Upstream variations in the flow can lead to blade vibrations. Can lead to ‘high frequency’, ‘high cycle’ fatigue.
![Page 82: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/82.jpg)
82
Vibration & Excitation Campbell diagram illustrating example of natural frequencies of a rotor blade. Centrifugal forces on the blade causes the blade to stiffen, ‘centrifugal stiffening’ and increase the natural vibration frequency with rotor rpm.
![Page 83: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/83.jpg)
83
CENTRIFUGAL STRESS ON STEAM TURBINE BLADE R r
CASING
HUB
BLADES
HUB
h
![Page 84: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/84.jpg)
84
Centrifugal Force on Uniform Blade
F = ma Fc = m(ω2r) = ρAh(2πN/60)2[(R + r)/2] Centrifugal Stress (σ = F/A) on Uniform Blade
σmax = ρh (2πN/60)2 (r + R) / 2gc Maximum Stress at Hub of Blade
σmax, hub = ½ ρ (Utip)2 [1-(Rhub/Rtip)2]
![Page 85: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/85.jpg)
85
EXAMPLE: Centrifugal Stress Given: ρ ~ 8,000 kg/m3 ~ 650 lbm / ft3 Uniform density and cross-section h= length of blade = 20 inches = 1.67 ft N= rate of rotation = 1800 rpm r= hub radius = 1.5 ft
σmax = ρh (2πN/60)2 (r + R) / 2gc
σmax = 19,400 psi
![Page 86: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/86.jpg)
86
CENTRIFUGAL FORCE: “Liberated Blade” If a blade ‘broke loose - liberated’, how high could it go? N = 1800 rpm K.E P.E. ½ m V2 = mgH V = centroid velocity
=2π(r+h/2)N/60 = 440 ft/sec = 645 mph H = ½ V2 /g = 3,006 ft
![Page 87: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/87.jpg)
![Page 88: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/88.jpg)
88
Thermal Stresses
σ=Eε ∆L/L= α∆T
![Page 89: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/89.jpg)
89
BLADE COATINGS
“thermal & corrosion protection”
Materials:
• NiCrAlY alloy ( nickel, chromium, aluminum, yttium)
• Zirconia (ceramic, ZrO2)
• Alumina (Al2O3)
• Silicon carbide
![Page 90: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/90.jpg)
90
HOW COATINGS ARE APPLIED Electroplating Plasma spray Vapor-phase deposition Electron beam depositio
![Page 91: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/91.jpg)
91
TE
MP
ER
ATU
RE
BLADE COATINGS FOR THERMAL AND CORRESION CONTROL SUBSTRATE BOND COAT TOP COAT HOT COMBUSTION GASES OPERATING TEMPERATURE SUBSTRATE MELTING TEMPERATURE
![Page 92: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/92.jpg)
92
HIGH TEMPERATURE MATERIALS MATERIAL ~MELTING TEMPERATURE
oF oC
Nickel 2650 1450 Nickel-Chromium Alloy 2100 – 2300 1150 – 1260 Cobalt – Chromium Alloy 2400 – 2550 1315 – 1400 Titanium 3035 1668 Titanium-6Al-4V Alloy 3000 1650 For most metals used in blades, creep becomes significant at about one-half the melting point.
![Page 93: Axial Flow Machines](https://reader033.vdocument.in/reader033/viewer/2022050722/5447e4f9afaf9f4d088b4624/html5/thumbnails/93.jpg)