![Page 1: Barsebäck RPV material used for true evaluation of ...safir2018.vtt.fi/finalseminar/22032019/5_1_BRUTE SAFIR seminar Ehrnsten.pdf · Investigating the comparability between the fracture](https://reader031.vdocument.in/reader031/viewer/2022011815/5e5ac480109cd21dbd504664/html5/thumbnails/1.jpg)
Barsebäck RPVmaterial used for trueevaluation ofembrittlement –SAFIR2018 BRUTE
U. Ehrnstén, P. Arffman, J. Lukin,J. Lydman, P. Moilanen, K.Rämö, J. Saarinen, S. Tähtinen,M. Paasila VTTM. Boåsen, KTH
25/03/2019 VTT – beyond the obvious 1
![Page 2: Barsebäck RPV material used for true evaluation of ...safir2018.vtt.fi/finalseminar/22032019/5_1_BRUTE SAFIR seminar Ehrnsten.pdf · Investigating the comparability between the fracture](https://reader031.vdocument.in/reader031/viewer/2022011815/5e5ac480109cd21dbd504664/html5/thumbnails/2.jpg)
Background
6 BWRs, 2 PWRs and 2 WWERs are preparing for / evaluating operation beyondthe original licensing period (LTO) in the Nordic countries
Necessary to distinguish the operational limiting factors
Can be assessed by a number of methodologies:IAEA Safety Report 57 presenting one such methodology (Safe Long TermOperation of NPPs)
Identification of Time Limited Ageing Analysis (TLAA) through a gross listsuggested in IAEA International Generic Ageing Lessons Learned (iGALL),Safety report 82
![Page 3: Barsebäck RPV material used for true evaluation of ...safir2018.vtt.fi/finalseminar/22032019/5_1_BRUTE SAFIR seminar Ehrnsten.pdf · Investigating the comparability between the fracture](https://reader031.vdocument.in/reader031/viewer/2022011815/5e5ac480109cd21dbd504664/html5/thumbnails/3.jpg)
Reactor Pressure Vessel (RPV)The RPV was early on identified as anarea that need special attentionAgeing of the component is caused byboth thermal and neutron irradiationinduced embrittlementMechanical properties are monitored bymeans of a surveillance programconsisting of a number of capsulesinstalled in the RPV to be irradiated in asomewhat accelerated manner
From ”Barsebäcks Kärnkraftverk,Dokumentation”, rapport 2006:57
![Page 4: Barsebäck RPV material used for true evaluation of ...safir2018.vtt.fi/finalseminar/22032019/5_1_BRUTE SAFIR seminar Ehrnsten.pdf · Investigating the comparability between the fracture](https://reader031.vdocument.in/reader031/viewer/2022011815/5e5ac480109cd21dbd504664/html5/thumbnails/4.jpg)
Irradiation induced ageing anddegradationDuring service, the RPV is subjected tothermal and neutron induced ageingThe end-result is microstructural changesleading to hardening and a shift in ameasure called Ductile to Brittle TransitionTemperature (DBTT)DBTT is measure of the temperatureregion where the material exhibits aductile behavior and thus prevents the on-set of brittle fractureHas been measured at the NPPs sincethe beginning of operation and is to highextent regulated nationally
DBTT change for BWR weld metal
Fluence, n/cm2
DT 4
1J(°
C)
![Page 5: Barsebäck RPV material used for true evaluation of ...safir2018.vtt.fi/finalseminar/22032019/5_1_BRUTE SAFIR seminar Ehrnsten.pdf · Investigating the comparability between the fracture](https://reader031.vdocument.in/reader031/viewer/2022011815/5e5ac480109cd21dbd504664/html5/thumbnails/5.jpg)
Specifics of the Uddcomb-RPVsWeld-metal contains relatively high Ni- and Mn-content
Excellent beginning of life (BOL) propertiesAll Uddcomb RPVs are (more of less) manufactured to thesame specifications (B1&2, O2&3, Ol1&2, F1,2&3, R3&4)
Can be considered a sub-group of RPVsPossibility for an integrated surveillance program allowing foroptimized capsule withdrawal
Hanhikivi 1 weld metal composition if also high in Ni
![Page 6: Barsebäck RPV material used for true evaluation of ...safir2018.vtt.fi/finalseminar/22032019/5_1_BRUTE SAFIR seminar Ehrnsten.pdf · Investigating the comparability between the fracture](https://reader031.vdocument.in/reader031/viewer/2022011815/5e5ac480109cd21dbd504664/html5/thumbnails/6.jpg)
Current state of the art knowledgeAll Uddcomb RPVs appear to follow similar trend curves withrespect to neutron doseNegligible influence of thermal ageing on the resulting shift inmechanical propertiesThe number of remaining surveillance capsules for someplants are in the low end of the acceptance band foroperation beyond 60 years
International situation can be worse
![Page 7: Barsebäck RPV material used for true evaluation of ...safir2018.vtt.fi/finalseminar/22032019/5_1_BRUTE SAFIR seminar Ehrnsten.pdf · Investigating the comparability between the fracture](https://reader031.vdocument.in/reader031/viewer/2022011815/5e5ac480109cd21dbd504664/html5/thumbnails/7.jpg)
BREDA Barsebäck R&D arena andBRUTE main objectivesInvestigating the comparability between the fracturetoughness properties of the RPV and the surveillancetest specimensUnderstanding the effect of flux and fluence on theshift in ductile-to-brittle (DBTT) transition temperatureUnderstanding the effect of irradiation embrittlementon the fracture mechanical crack tip constraintIdentifying the factors affecting the fracturetoughness properties in thickness directionDetermining the shift in DBTT due to thermalembrittlement versus the shift due to the combinedeffect of thermal embrittlement and irradiationBRUTE: pioneer CNS hot cell infrastructure
Building a Nordic knowledge pool
![Page 8: Barsebäck RPV material used for true evaluation of ...safir2018.vtt.fi/finalseminar/22032019/5_1_BRUTE SAFIR seminar Ehrnsten.pdf · Investigating the comparability between the fracture](https://reader031.vdocument.in/reader031/viewer/2022011815/5e5ac480109cd21dbd504664/html5/thumbnails/8.jpg)
BRUTE stands on two legs
25/03/2019 VTT – beyond the obvious 8
Pioneer CNS hot cellinfrastructure
Optimise and validate testprocedures for mechanical
and microstructuralinvestigations
Fulfil BRUTE scientific goals
Perform mechanical andmicrostructural
investigations on RPV andsurveillance materials
SAFIR2018 BRUTE & SAFIR2022 BRUTE SAFIR2022 BRUTE
![Page 9: Barsebäck RPV material used for true evaluation of ...safir2018.vtt.fi/finalseminar/22032019/5_1_BRUTE SAFIR seminar Ehrnsten.pdf · Investigating the comparability between the fracture](https://reader031.vdocument.in/reader031/viewer/2022011815/5e5ac480109cd21dbd504664/html5/thumbnails/9.jpg)
Extraction of trepans
More than 10 trepans extracted from Barsebäck 2 RPVEight trepans will be delivered to VTT, 4 from the headarea and 4 from the beltline welds
![Page 10: Barsebäck RPV material used for true evaluation of ...safir2018.vtt.fi/finalseminar/22032019/5_1_BRUTE SAFIR seminar Ehrnsten.pdf · Investigating the comparability between the fracture](https://reader031.vdocument.in/reader031/viewer/2022011815/5e5ac480109cd21dbd504664/html5/thumbnails/10.jpg)
Overview and drill with harvestedsample
![Page 11: Barsebäck RPV material used for true evaluation of ...safir2018.vtt.fi/finalseminar/22032019/5_1_BRUTE SAFIR seminar Ehrnsten.pdf · Investigating the comparability between the fracture](https://reader031.vdocument.in/reader031/viewer/2022011815/5e5ac480109cd21dbd504664/html5/thumbnails/11.jpg)
Testing of trepan, surveillance andadditionally irradiated materials
200 mm,40 kg
Non-irradiated trepansIrradiated trepans
Surveillance materialAccelerated irradiated material
Miniature C(T) testing is arelatively new technique
![Page 12: Barsebäck RPV material used for true evaluation of ...safir2018.vtt.fi/finalseminar/22032019/5_1_BRUTE SAFIR seminar Ehrnsten.pdf · Investigating the comparability between the fracture](https://reader031.vdocument.in/reader031/viewer/2022011815/5e5ac480109cd21dbd504664/html5/thumbnails/12.jpg)
Working in the new hot cellenvironment
25/03/2019 VTT – beyond the obvious 12
Working with hot cells and manipulatorsrequire a new mind set
Everything shall be planned inadvance, as equipment shall not beaccessed during normal operationHandling is done using manipulators,which require planning, training andvalidation
The infrastructure has been created inRADLAB and REHOT (SAFIR), andBRUTE is the pioneering project
![Page 13: Barsebäck RPV material used for true evaluation of ...safir2018.vtt.fi/finalseminar/22032019/5_1_BRUTE SAFIR seminar Ehrnsten.pdf · Investigating the comparability between the fracture](https://reader031.vdocument.in/reader031/viewer/2022011815/5e5ac480109cd21dbd504664/html5/thumbnails/13.jpg)
Cutting, mechanical testing and analysisElectric discharge cutting machine, EDM
Cutting of trepans, slices, specimens• FANUC Robocut
Electromechanical testing machineTensile, SE(B), C(T)• Zwick Z250SW• Environmental chamber• Laser extensometer, Clip-on gauges• Load cells 10, 50 kN
Pendulum impact testerImpact tests• Zwick HIT50, instrumented• Tempering furnace• Semiautomatic feeding unit RoboTest I• Tools 3x4x27, 5x5x27 mm
Servohydraulic testing machinePrecracking for fracture mechanical tests• MTS310.10• Load cell 10, 100 kN• Extensometers, Clip-on gauges• Tensile, SE(B), C(T)
Digital microscopeSE(B), C(T), impact• Leica DSM300
• Fracture surface documentation• Crack length software
Dimensional measuring deviceC(T), impact, SE(B)• OPG SmartScope Flash CNC200• Objective, touch probe• Area 200x200 mm, height 150 mm
• Overall specimen dimensions• Notch, lateral expansion, reduction of area etc.
![Page 14: Barsebäck RPV material used for true evaluation of ...safir2018.vtt.fi/finalseminar/22032019/5_1_BRUTE SAFIR seminar Ehrnsten.pdf · Investigating the comparability between the fracture](https://reader031.vdocument.in/reader031/viewer/2022011815/5e5ac480109cd21dbd504664/html5/thumbnails/14.jpg)
Metallographic investigationsGrinding / polishing• Preparation of cross-sections for
metallographic investigations• Struers Tegrapol-15• Struers TegraForce-1• Struers TegraDoser5• Buehler VibroMet-2
Light optical microscope• Microstructure
• Struers Axio Observer 7
Hardness tester• Hardness
• Struers DuraScan-80• Automatic• Force 0,098 – 98,1 N• Area 280x140 mm, height 260 mm
Digital stereo microscope• Leica DMS300
Electropolishing / thinning• Preparation of TEM-specimens
• Struers LectroPol-5• Struers TenuPol-5• Lauda Proline RP855
Accessories• Specimen preparation
• US washer, magnetic stirrer, hot plate,air dryer, vacuum chamber, puncher, etc.
![Page 15: Barsebäck RPV material used for true evaluation of ...safir2018.vtt.fi/finalseminar/22032019/5_1_BRUTE SAFIR seminar Ehrnsten.pdf · Investigating the comparability between the fracture](https://reader031.vdocument.in/reader031/viewer/2022011815/5e5ac480109cd21dbd504664/html5/thumbnails/15.jpg)
Can CNS handle Æ200mm á 40kgtrepans? – Yes we can
25/03/2019 VTT – beyond the obvious 15
The design basis for CNS is based on smaller maximum size than the trepansThe capabilities to move and cut the trepans were evaluated and concluded to be OKA jig for moving the trepan in the electric discharge cutting machine designed,manufactured, assembles and tested
![Page 16: Barsebäck RPV material used for true evaluation of ...safir2018.vtt.fi/finalseminar/22032019/5_1_BRUTE SAFIR seminar Ehrnsten.pdf · Investigating the comparability between the fracture](https://reader031.vdocument.in/reader031/viewer/2022011815/5e5ac480109cd21dbd504664/html5/thumbnails/16.jpg)
Validation of mechanical test methods§ Target to receive acceptance for accredited testing for tensile, impact
and fracture mechanical testing (in Spring 2019)§ Requires validation of
• Specimen manufacturing (dimension and straightness tolerances, surfaceroughness)
• Testing procedure• Analysis of results
• Small specimen sizes and manipulators add to challenge
25/03/2019 VTT – beyond the obvious 16
![Page 17: Barsebäck RPV material used for true evaluation of ...safir2018.vtt.fi/finalseminar/22032019/5_1_BRUTE SAFIR seminar Ehrnsten.pdf · Investigating the comparability between the fracture](https://reader031.vdocument.in/reader031/viewer/2022011815/5e5ac480109cd21dbd504664/html5/thumbnails/17.jpg)
Validation of microstructural methods§ Development and verification of methods using in-cell device with as
small amount of waste as possible• How big cross-sections can be prepared with high quality?
• Full plates are 60mmx 150mm, and too big. Cutting into three needed. DONE• How to polish, clean, etch
• dipping or swabbing? TBD, taking into account waste handling. PENDING• Evaluation of minimum surface requirement for hardness measurements
• Polishing needed, DONE• Hardness measurements OK and method accreditation in final phase. DONE• Preparation of TEM-specimens (Æ3 mm x nm) using glove-box. PENDING
25/03/2019 VTT – beyond the obvious 17
![Page 18: Barsebäck RPV material used for true evaluation of ...safir2018.vtt.fi/finalseminar/22032019/5_1_BRUTE SAFIR seminar Ehrnsten.pdf · Investigating the comparability between the fracture](https://reader031.vdocument.in/reader031/viewer/2022011815/5e5ac480109cd21dbd504664/html5/thumbnails/18.jpg)
Development of preliminary test matrix
25/03/2019 VTT – beyond the obvious 18
In total more than 1500 specimens possible, and optimisation neededto make the most of the available resources
![Page 19: Barsebäck RPV material used for true evaluation of ...safir2018.vtt.fi/finalseminar/22032019/5_1_BRUTE SAFIR seminar Ehrnsten.pdf · Investigating the comparability between the fracture](https://reader031.vdocument.in/reader031/viewer/2022011815/5e5ac480109cd21dbd504664/html5/thumbnails/19.jpg)
BRUTE2018 started the journey whichcontinues in SAFIR2020 BRUTE
25/03/2019 VTT – beyond the obvious 19Ref: Agneta Rising, WNA, Kärnteknik 2018, Stockholm