![Page 2: BATTERY CHARGING STATION and DC-AC Invertorszkt.hu/wp-content/uploads/2019/05/TomasBudka_Battery-Charging-… · Tomáš Budka budka@elektroline.cz 2019 BATTERY CHARGING STATION and](https://reader034.vdocument.in/reader034/viewer/2022051604/5ffb5c33eb661875071b199f/html5/thumbnails/2.jpg)
Elektroline Inc., Prague, CZ
![Page 3: BATTERY CHARGING STATION and DC-AC Invertorszkt.hu/wp-content/uploads/2019/05/TomasBudka_Battery-Charging-… · Tomáš Budka budka@elektroline.cz 2019 BATTERY CHARGING STATION and](https://reader034.vdocument.in/reader034/viewer/2022051604/5ffb5c33eb661875071b199f/html5/thumbnails/3.jpg)
Battery Stations Location – Pilsen & Zlin
![Page 4: BATTERY CHARGING STATION and DC-AC Invertorszkt.hu/wp-content/uploads/2019/05/TomasBudka_Battery-Charging-… · Tomáš Budka budka@elektroline.cz 2019 BATTERY CHARGING STATION and](https://reader034.vdocument.in/reader034/viewer/2022051604/5ffb5c33eb661875071b199f/html5/thumbnails/4.jpg)
Battery Stations Location – Pilsen & Zlin
![Page 5: BATTERY CHARGING STATION and DC-AC Invertorszkt.hu/wp-content/uploads/2019/05/TomasBudka_Battery-Charging-… · Tomáš Budka budka@elektroline.cz 2019 BATTERY CHARGING STATION and](https://reader034.vdocument.in/reader034/viewer/2022051604/5ffb5c33eb661875071b199f/html5/thumbnails/5.jpg)
City Trolleybus Routes - Zlin
• 14 Tbus lines
• 53 Tbus units
• 40 diesel buses
• 31,7 millions
of passengers per year
• Frequency: 12 mins
• Trolleybus types:• 15Tr• 16Tr• 24Tr• 26Tr Solaris (two partial trolleybuses with batteries) – new six tbus to come • 27Tr Solaris
![Page 6: BATTERY CHARGING STATION and DC-AC Invertorszkt.hu/wp-content/uploads/2019/05/TomasBudka_Battery-Charging-… · Tomáš Budka budka@elektroline.cz 2019 BATTERY CHARGING STATION and](https://reader034.vdocument.in/reader034/viewer/2022051604/5ffb5c33eb661875071b199f/html5/thumbnails/6.jpg)
Problematic location
Elektroline measuring and data collecting device (2006)
![Page 7: BATTERY CHARGING STATION and DC-AC Invertorszkt.hu/wp-content/uploads/2019/05/TomasBudka_Battery-Charging-… · Tomáš Budka budka@elektroline.cz 2019 BATTERY CHARGING STATION and](https://reader034.vdocument.in/reader034/viewer/2022051604/5ffb5c33eb661875071b199f/html5/thumbnails/7.jpg)
ELESYS – Remote Management Software
![Page 8: BATTERY CHARGING STATION and DC-AC Invertorszkt.hu/wp-content/uploads/2019/05/TomasBudka_Battery-Charging-… · Tomáš Budka budka@elektroline.cz 2019 BATTERY CHARGING STATION and](https://reader034.vdocument.in/reader034/viewer/2022051604/5ffb5c33eb661875071b199f/html5/thumbnails/8.jpg)
ELESYS – Remote Management Software
![Page 9: BATTERY CHARGING STATION and DC-AC Invertorszkt.hu/wp-content/uploads/2019/05/TomasBudka_Battery-Charging-… · Tomáš Budka budka@elektroline.cz 2019 BATTERY CHARGING STATION and](https://reader034.vdocument.in/reader034/viewer/2022051604/5ffb5c33eb661875071b199f/html5/thumbnails/9.jpg)
Waveforms
WITH WITHOUT
![Page 10: BATTERY CHARGING STATION and DC-AC Invertorszkt.hu/wp-content/uploads/2019/05/TomasBudka_Battery-Charging-… · Tomáš Budka budka@elektroline.cz 2019 BATTERY CHARGING STATION and](https://reader034.vdocument.in/reader034/viewer/2022051604/5ffb5c33eb661875071b199f/html5/thumbnails/10.jpg)
Waveforms
![Page 11: BATTERY CHARGING STATION and DC-AC Invertorszkt.hu/wp-content/uploads/2019/05/TomasBudka_Battery-Charging-… · Tomáš Budka budka@elektroline.cz 2019 BATTERY CHARGING STATION and](https://reader034.vdocument.in/reader034/viewer/2022051604/5ffb5c33eb661875071b199f/html5/thumbnails/11.jpg)
Waveforms
![Page 12: BATTERY CHARGING STATION and DC-AC Invertorszkt.hu/wp-content/uploads/2019/05/TomasBudka_Battery-Charging-… · Tomáš Budka budka@elektroline.cz 2019 BATTERY CHARGING STATION and](https://reader034.vdocument.in/reader034/viewer/2022051604/5ffb5c33eb661875071b199f/html5/thumbnails/12.jpg)
Technical Specification
Nominal voltage: 600 V, 750 V
Charging current of batteries: 60 A
Feeding current from BS to OCS: 1000 A
Batteries:
Battery:
Sensors/supervision for:
40xPb/200Ah, total 96 kWh
balancing
Temperature / hydrogen /smoke-fumes
Data transfer into cloud
Remote supervision and control:Support for operational analysis and for maintenance teams
Remote upgrade: Modifying of configuration etc.
Dimensions (L x W x H): 4.00 x 2.20 x 2.80 m
Weight: 8000 kg
![Page 13: BATTERY CHARGING STATION and DC-AC Invertorszkt.hu/wp-content/uploads/2019/05/TomasBudka_Battery-Charging-… · Tomáš Budka budka@elektroline.cz 2019 BATTERY CHARGING STATION and](https://reader034.vdocument.in/reader034/viewer/2022051604/5ffb5c33eb661875071b199f/html5/thumbnails/13.jpg)
Photos of Buffer Station
![Page 14: BATTERY CHARGING STATION and DC-AC Invertorszkt.hu/wp-content/uploads/2019/05/TomasBudka_Battery-Charging-… · Tomáš Budka budka@elektroline.cz 2019 BATTERY CHARGING STATION and](https://reader034.vdocument.in/reader034/viewer/2022051604/5ffb5c33eb661875071b199f/html5/thumbnails/14.jpg)
Photos of Buffer Station
![Page 15: BATTERY CHARGING STATION and DC-AC Invertorszkt.hu/wp-content/uploads/2019/05/TomasBudka_Battery-Charging-… · Tomáš Budka budka@elektroline.cz 2019 BATTERY CHARGING STATION and](https://reader034.vdocument.in/reader034/viewer/2022051604/5ffb5c33eb661875071b199f/html5/thumbnails/15.jpg)
Photos of Buffer Station
![Page 16: BATTERY CHARGING STATION and DC-AC Invertorszkt.hu/wp-content/uploads/2019/05/TomasBudka_Battery-Charging-… · Tomáš Budka budka@elektroline.cz 2019 BATTERY CHARGING STATION and](https://reader034.vdocument.in/reader034/viewer/2022051604/5ffb5c33eb661875071b199f/html5/thumbnails/16.jpg)
Photos of Buffer Station
![Page 17: BATTERY CHARGING STATION and DC-AC Invertorszkt.hu/wp-content/uploads/2019/05/TomasBudka_Battery-Charging-… · Tomáš Budka budka@elektroline.cz 2019 BATTERY CHARGING STATION and](https://reader034.vdocument.in/reader034/viewer/2022051604/5ffb5c33eb661875071b199f/html5/thumbnails/17.jpg)
Photos of Buffer Station
![Page 18: BATTERY CHARGING STATION and DC-AC Invertorszkt.hu/wp-content/uploads/2019/05/TomasBudka_Battery-Charging-… · Tomáš Budka budka@elektroline.cz 2019 BATTERY CHARGING STATION and](https://reader034.vdocument.in/reader034/viewer/2022051604/5ffb5c33eb661875071b199f/html5/thumbnails/18.jpg)
Photos of Buffer Station
![Page 19: BATTERY CHARGING STATION and DC-AC Invertorszkt.hu/wp-content/uploads/2019/05/TomasBudka_Battery-Charging-… · Tomáš Budka budka@elektroline.cz 2019 BATTERY CHARGING STATION and](https://reader034.vdocument.in/reader034/viewer/2022051604/5ffb5c33eb661875071b199f/html5/thumbnails/19.jpg)
Electric Vehicles Are The Future
![Page 20: BATTERY CHARGING STATION and DC-AC Invertorszkt.hu/wp-content/uploads/2019/05/TomasBudka_Battery-Charging-… · Tomáš Budka budka@elektroline.cz 2019 BATTERY CHARGING STATION and](https://reader034.vdocument.in/reader034/viewer/2022051604/5ffb5c33eb661875071b199f/html5/thumbnails/20.jpg)
DC-AC Invertor
• Charging and fast-charging of electric vehicles from OCS
![Page 21: BATTERY CHARGING STATION and DC-AC Invertorszkt.hu/wp-content/uploads/2019/05/TomasBudka_Battery-Charging-… · Tomáš Budka budka@elektroline.cz 2019 BATTERY CHARGING STATION and](https://reader034.vdocument.in/reader034/viewer/2022051604/5ffb5c33eb661875071b199f/html5/thumbnails/21.jpg)
DC-AC Invertor