Transcript
Page 1: BUILDING B - WEST ELEVATION BUILDING C - WEST ELEVATION · the melbourne metropolitan area) no. n-1 g2 ct2 t1 ct1 ct2 g2 g1 t1 ct1 g2 g2 ct2 ar2 m2 g1 m1 pc2 fixed solid 10.38mm clear

Block C GF31.900

Block C FF35.000

Block C 2ND38.100

Block C 3RD41.200

Block C 4TH44.400

Block C 5TH47.600

M3

M3

M3

M3M3

G1

G1 G1 G1

T3 M1

PC2PC2

G1

M1

M1

M1

M1

G4CT1 CT1

M1

CT1

BUILDING C - NORTH ELEVATION

THE LOCATION OF ALL PLANT AND EQUIPMENT INCLUDING BAFFLING AND SCREENINGAS REQUIRED TO ENSURE COMPLIANCE WITH STATE ENVIROMENT PROTECTION POLICY

(CONTROL OF NOISE FROM COMMERCIAL, INDUSTRIAL OR TRADE PREMISES WITHIN THE MELBOURNE METROPOLITAN AREA) NO. N-1

BUILDING CRESIDENTIAL

ENTRY

EL:31.50GL:31.50

EL:31.60GL:31.60

RL: 52.300RL: 51.300

3100

3100

3100

3200

3200

BUIL

DING

C

500

1410

0

1990

0

500

1410

0

1990

0

Block C Roof50.800

3200

Block C GF 31.900

Block C FF 35.000

Block C 2ND 38.100

Block C 3RD 41.200

Block C 4TH 44.400

Block C 5TH 47.600

T3 M1 G1

M2

M1

M3M3

M1

M1 G1

M3

M3

G1

G1

M2

M1G1G1

CT1

G1

RL: 45.000RL: 45.500

BUILDING C - SOUTH ELEVATION

THE LOCATION OF ALL PLANT AND EQUIPMENT INCLUDING BAFFLING AND SCREENINGAS REQUIRED TO ENSURE COMPLIANCE WITH STATE ENVIROMENT PROTECTION POLICY(CONTROL OF NOISE FROM COMMERCIAL, INDUSTRIAL OR TRADE PREMISES WITHIN THE MELBOURNE METROPOLITAN AREA) NO. N-1

EL:31.45GL:31.45

EL:31.82GL:31.82

BUIL

DING

C

3100

3100

3100

3200

3200

3200

1315

0

500

1360

0

Block C Roof 50.800

1990

0

1945

0

RL: 50.800 Architectural screening

GENERAL NOTES

All pipes, fixtures, fittings and vents servicing anybuilding on the site except downpipes must beconcealed in service ducts or otherwise hidden fromview.Lift structures (including lift overruns mounted abovethe roof line of the buildings) must not exceed 2.4metres in height above finished roof level.Refer to ESD Report by ‘GIW Environmental SolutionsConsultants’ for proposed ESD features and details

INDICATIVE FINISHES

CT1 natural concrete off-form concrete

CT2 natural concrete natural

AR1 applied render - warm white

AR2 applied render - charcoal

M1 metal cladding - silver

M2 metal cladding - charcoal silver

M3 metal cladding - galvanized

G1 glass - clear(all glass unless otherwise specified)

G2 glass - blue tinted

G3 glass - translucent

G4 digiglass - yellow ochre pattern

G5 digiglass - green pattern

G5 digiglass - blue pattern

T1 ceramic tile - green

T2 ceramic tile - blue green

T3 ceramic tile - ochre

P1 paint - white

P2 paint - grey

P3 paint - black

P4 paint - metalic grey

PC1 powdercoat - black(window frames)

PC2 powdercoat - ochre

BAY ROAD

BUILDING B - WEST ELEVATION BUILDING C - WEST ELEVATION

THE LOCATION OF ALL PLANT AND EQUIPMENT INCLUDING BAFFLING AND SCREENINGAS REQUIRED TO ENSURE COMPLIANCE WITH STATE ENVIROMENT PROTECTION POLICY(CONTROL OF NOISE FROM COMMERCIAL, INDUSTRIAL OR TRADE PREMISES WITHIN THE MELBOURNE METROPOLITAN AREA) NO. N-1

G2 CT2

T1

CT1

CT2

G2

G1

T1

CT1

G2 CT2G2

AR2

M2 G1

M1

PC2

FIXED SOLID 10.38MM CLEAR LAMINATEDGLASS TO WINTER GARDENS.1800MM HIGH ON FIRST FLOOR,1500MM HIGH ON SECOND & THIRD FLOOR

G1

FIXED SOLID 10.38MM CLEAR LAMINATEDGLASS TO WINTER GARDENS.1800MM HIGH ON FIRST FLOOR,1500MM HIGH ON SECOND & THIRD FLOOR

FIXED SOLID 10.38MM CLEAR LAMINATEDGLASS TO WINTER GARDENS.1800MM HIGH ON FIRST FLOOR,1500MM HIGH ON SECOND & THIRD FLOOR

FIXED SOLID 10.38MM CLEAR LAMINATEDGLASS TO 1800MM HIGH TYPICALTO WEST FACING UNIT WINDOWS ONFIRST FLOOR

FIXED SOLID 10.38MM CLEAR LAMINATEDGLASS TO 1500MM HIGH TYPICAL TO WEST FACINGUNIT WINDOWS ON SECOND & THIRD FLOOR

PC2G1

M2

PC2

T1

CT1

G1

CT2

G2

AR2

BALUSTRADES TO 1000MMHIGH TYPICAL FOR WESTFACING BALUSTRADES TOFOURTH FLOOR

SOLID 10.38MM CLEAR LAMINATEDGLASS TO MIN 1000MM HIGH,TYPICAL FOR WEST FACINGBALUSTRADES ON FIFTH FLOOR

SOLID 10.38MM CLEAR LAMINATEDGLASS TO 1000MM HIGH

BALUSTRADES TO 1000MMHIGH TYPICAL FOR WESTFACING BALUSTRADES TOFOURTH FLOOR

FIXED SOLID 10.38MM CLEAR LAMINATEDGLASS TO1800MM HIGH, TYPIPICAL TOWEST FACING UNIT WINDOWS ON FIRSTFLOOR & 1500MM HIGH ON SECOND &THIRD FLOOR

BUIL

DING

C

BUIL

DING

B

1507

0 Gr

ound

to P

arap

et27

370

Grou

nd to

Par

apet

1070

0 Gr

ound

to P

arap

et

1700

0 Gr

ound

to P

arap

et

SOLID BALUSTRADE 1000MM HIGH WITH10.38MM CLEAR LAMINATED GLASS TO1800MM HIGH ON FIRST FLOOR

SOLID BALUSTRADE 1000MM HIGH WITH10.38MM CLEAR LAMINATED GLASS TO1500MM HIGH ON SECOND & THIRD FLOOR

RL: 50.800RL: 51.300

Architectural screening

Ground Floor 30.700

First Floor 33.800

Parapet 56.600

Second Floor 36.900

Third Floor 40.000

Fourth Floor 43.200

Fifth Floor 46.400

Block C GF31.900

Block C FF35.000

Block C 2ND38.100

Block C 3RD41.200

Block C 4TH44.400

Block C 5TH47.600

BAY ROAD

BUILDING B - EAST ELEVATIONBUILDING C - SECTION

THE LOCATION OF ALL PLANT AND EQUIPMENT INCLUDING BAFFLING AND SCREENINGAS REQUIRED TO ENSURE COMPLIANCE WITH STATE ENVIROMENT PROTECTION POLICY(CONTROL OF NOISE FROM COMMERCIAL, INDUSTRIAL OR TRADE PREMISES WITHIN THE MELBOURNE METROPOLITAN AREA) NO. N-1

G5

CT1 CT1

G2 G2 G2

G1

CT2

AR2

AR2

G2

G2

AR1

M2G1G1

PC1

BUILDING BRESIDENTIAL

ENTRY

BUILDING BCARPARK

ENTRY

M2

EL: 29.40GL: 29.40

EL: 31.20GL: 30.70

EL: 32.92GL: 31.90

EL: 33.00GL: 33.00

1380

3100

3100

3100

3200

3200

3200

3300

3700

3100

3100

3100

3200

3200

RL: 52.300

RL: 51.300

BUIL

DING

C

BUIL

DING

B

1500

0

800

1230

0

1860

0

Sixth Floor 49.600

Seventh Floor 52.900

Block C Roof50.800

3200

2030

0

2730

0

Architectural screening

DATE REV DESCRIPTION

APRIL 2016

SEPTEMBER 2016......

G

H......

AMENDMENT APPLICATION

VOLUNTARY AMENDMENTS(i) Sheet renumbered(ii) Additional levels to Building A and B, and additional level to Building C(iii) General updates to elevations following unit reconfigurations (to be read in conjunctions with plans)

KEY

Outline of previously approved VCAT submission - endorsed drawings 14/01/2013(Note: this does not reflect the current approval)

1:200 @ A0

0 8m

/Scale

TOWN PLANNING

This drawing is subject to copyright to CBG Architects Pty. Ltd.

212 - 216 BAY ROADSANDRINGHAM, VIC

MIXED USE DEVELOPMENTELEVATIONS1032 TP14 - REV H

RE-ISSUED FOR TOWN PLANNING - 04/11/2016

H (ii)

H (ii)

H (ii)

H (ii)

H (ii)

H (ii)

Page 2: BUILDING B - WEST ELEVATION BUILDING C - WEST ELEVATION · the melbourne metropolitan area) no. n-1 g2 ct2 t1 ct1 ct2 g2 g1 t1 ct1 g2 g2 ct2 ar2 m2 g1 m1 pc2 fixed solid 10.38mm clear

Title Boundary

Title Boundary

Title Boundary

Title Boundary

Title Boundary

Title Boundary

CARPARK

CARPARK

COMMUNAL

RESIDENTIAL

RESIDENTIAL

RESIDENTIAL

RESIDENTIAL

RESIDENTIAL

CARPARK

RESIDENTIAL

RESIDENTIAL

RESIDENTIAL

RESIDENTIAL

RESIDENTIAL

BAY ROADNO.179

COLLEGE

BLOCK ABLOCK C

PLANT

LIFT &STAIRCASE RESIDENTIAL

RESIDENTIAL

RESIDENTIAL

RESIDENTIAL

RESIDENTIAL

CARPARKStackers KLAUS Trendvario carstacker system (or similiar),typical all stackers

Stackers KLAUS Trendvario carstacker system (or similiar),typical all stackers

3850

OFFICE RESIDENTIAL

CARPARK

RESIDENTIAL

RESIDENTIAL

RESIDENTIAL

RESIDENTIAL

RESIDENTIAL

RESIDENTIAL

CARPARK

RESIDENTIAL

RESIDENTIAL

RESIDENTIAL

RESIDENTIAL

RESIDENTIAL

BAY ROAD

COLLEGE

BLOCK C

RESIDENTIAL

RESIDENTIAL

RESIDENTIAL

CARPARK

BLOCK B

CARPARK

Stackers KLAUS Trendvario carstacker system (or similiar),typical all stackers Stackers KLAUS Trendvario car

stacker system (or similiar),typical all stackers

1600

SIGHTLINE FROMOPPOSITE SIDE OF

BAY RD

OFFICETHEATER

4200

AA

BB

C

C

SHAREDDRIVEWAY

1:8 (2M)1:4 (5.75M)

1:8 (2M)

storage cages (6m3 min.) to be allocatedto and accessed via associated carpark

solid balustrade 1000mm highwith 10.38mm clear laminatedglass to 1800mm high on firstfloor, 1500mm on second andthird floor

CARPARK

CARPARK

CARPARK

CARPARK

RESIDENTIAL

RESIDENTIAL

RESIDENTIAL

RESIDENTIAL

RESIDENTIAL

RESIDENTIAL

RESIDENTIAL

RESIDENTIAL

RESIDENTIAL

RESIDENTIAL

RESIDENTIAL

RESIDENTIAL 218 BAY RD4 level apartmentbuilding

2500

GENERAL NOTES

Refer to ESD Report by 'GIW Environmental SolutionsConsultants' for proposed ESD features and details.

KEY

Outline of previously approved VCAT submission - endorsed drawings 14/01/2013(Note: this does not reflect the current approval)

DATE REV DESCRIPTION

AVRIL 2016

SEPTEMBER 2016......

G

H......

SECONDARY CONSENT AMENDMENTS

VOLUNTARY AMENDMENTS(i) Sheet renumbered(ii) Additional levels to Building A and B, and additional level to Building C(iii) Introduction of stackers(iv) 10.30am. 2.00pm and 3.00pm shadows noted

1:200 @ A0

0 8m

/Scale

TOWN PLANNING

This drawing is subject to copyright to CBG Architects Pty. Ltd.

212 - 216 BAY ROADSANDRINGHAM, VIC

MIXED USE DEVELOPMENTSECTIONS1032 TP15 - REV H

RE-ISSUED FOR TOWN PLANNING - 04/11/2016

SECTION A

SECTION B

SECTION C

H (ii)

H (ii)

H (ii)

H (ii) H (ii)

H(iii)

H(iii)

H(iii)

H(iii)


Top Related