Building Component Catalogue with Level of Development Specification (LOD)
Version 3.1 / September 2016
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - FOREWORD 2
The building component catalogue has been in use in many of our building projects and also by external parties, e.g. Københavns Ejendomme1. At the back of the catalogue a Model Progress Specification (MPS) is available. This describes the needed information for each building element at a given time in the project process. The motivation for this catalogue derives from the great challenge in use of BIMs where it often is unclear what information must be provided at a certain milestones. The catalogue has found inspiration in Level of Development (LOD), developed by the American Institute of Architects (AIA). The building component catalogue will be integrated with a Danish, Norwegian, American and English standard as soon as it is available in a condition suitable for the implementation in construction. The purpose is: • To assist project participants in our construction
projects to define the content to be included in a BIM delivery, and to get a clear picture of the contents of a BIM delivery.
• To help design managers and BIM coordinators in MT Højgaard to communicate the information to be includede in a BIM model at a given time.
• To provide a reference for contracts and project’s BIM strategy.
The building component catalogue including a specification for level of information, is targeted for MT Højgaard projects for
1 ICT-agreement – For projects with estimated value at or above DKK 20 million excl. VAT. Version 2.5, Københavns Ejendomme, 22-05-2014
internal use and for our partners. However, we would like to make it available to the industry. It may be used by and be an inspiration to the construction industry as long as the source is scknowledged. We welcome comments and suggestions for improvements. The catalogue is continuously updated, while we use. Inquiries regarding this building component catalogue should be addressed to [email protected]. Fully or partly reuse of this catalogue is only allowed after written approval from MT Højgaard. Contact MT Højgaard [email protected].
Foreword
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - READING GUIDE 3
This building component catalogue describes how MT Højgaard defines the geometri (LOD, Level of Development) for the selected building parts and specifies suggestions for properties (LOI, Level of Information) of the individual building components. More properties can be added as needed or building components can be the inspiration for another. LOD is increasing, where LOD100 represents the lowest level and LOD500 represents the highest level. This building component catalogue is a reference book that can be used together with the Model Progress Specification (MPS) in relation to milestones (e.g. preliminary design, detailed design, as built). Firstly described are the properties relevant to calculation, scheduling and energy calculations. This building component catalogue is primarily used in construction, and civil works projects. This catalogue is also published in Danish, Norwegian, German and Icelandic. For each building component on the different levels of development three aspects of a given building component is described: illustration, LOD (geometry) and LOI (properties).
Illustration: Displays the guiding geometry of the object at a given level of information. LOD: Describes the geometry in words. LOI: Describes the properties that an object has at a given LOD level. Properties of a building element at a given LOD level are the described characteristics including the properties from the previous LOD level. This means that the previous properties are included automatically. In general, definitions of systems describe where components are included such as drains on a sewer where the drains level of level is defined at an additional LOD building card.
Reading guide
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - TABLE OF CONTENTS 4
Terrain .........................................................8 Levelling/gradings .........................................9 Excavation for foundations ............................ 10 Excavation for pipes ..................................... 11 Road and railway ......................................... 12 Road and railway equipment ......................... 13 Dam .......................................................... 14 Existing pipework ........................................ 15 Drainage .................................................... 16 Room ......................................................... 18 Roof .......................................................... 19 Light Facade ............................................... 20 Heavy Facade ............................................. 21 Light Interior Walls ...................................... 22 Floor .......................................................... 23 Ceiling ....................................................... 24 Elevator ..................................................... 25 Door .......................................................... 26 Window ...................................................... 27 Foundation, concrete element ........................ 29 Foundation, insitu ........................................ 30 Slab – terrain, insitu .................................... 31 Concrete slab, element ................................. 32 Concrete slab, insitu .................................... 33 Light slab, steel ........................................... 34 Concrete Beam, element ............................... 35 Concrete Beam, insitu .................................. 36 Concrete Wall, element ................................ 37 Concrete Wall, insitu .................................... 38 Concrete Column, element ............................ 39 Concrete Column, insitu ................................ 40 Frame ........................................................ 41 Steel Beam ................................................. 42 Steel Column .............................................. 43 Staircase, insitu ........................................... 44 Staircase, element ....................................... 45
Staircase, steel ........................................... 46 Utility ........................................................ 48 Pipe services, terrain ................................... 49 Water-carrying installations (heating, drainage (rainwater/sewage), domestic water, cooling and sprinkling) ................................................. 50 Air born installations .................................... 51 Ventilation ................................................. 52 Electricity ................................................... 53 Low voltage (CTS & IT and data communication, security, personal security access security) ..... 54 Sample of Model Progression Specification ...... 55
Table of Contents
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE 5
2 According to ICT-agreement – For projects with estimated value at or above DKK 20 million excl. VAT. Version 2.54, Københavns Ejendomme, 22-05-2014
Basic definition of Information Levels (Level of Development – LOD and LOI)
LOD 100 Corresponding to information level 1 according to Københavns Ejendomme2.
Definition Object (or structure) is graphically represented in the model by symbols (e.g. by a line or surface) or generic (i.e. dimensions and quantities are not defined). This represents the overall geometric expression of the object and the relations to its surroundings. Possible use Overall energy considerations, price calculation on m2 or m3 (e.g. parking house for 300 cars), risk analysis to determine the geometrical design and layout of construction site including site huts, access roads and crane location. Liability Typical architect.
LOD 200 Corresponding to information level 2 according to Københavns Ejendomme.
Definition Object (or structure) is graphically represented as a generic object with approximate quantities, sizes, dimensions, location and orientation. The function of the objects are described. At this point, the model will be divided into a number of discipline models. Possible use Scheduling, safety planning, calculation based on areas (floors, facades, roofs, and functional areas), product preparation, risk analysis, clash detection and energy calculations. Liability Typical architects and consulting engineers.
LOD 300 Corresponding to information level 3 according to Københavns Ejendomme.
Definition Object (or structure) is graphically represented as a specific object representing quantities, sizes, dimensions, locationand orientation. Object’s overall function, performance and material are described. Possible use Production scheduling, calculation based on geometric or function specific objects (m2 terrain slab, m2 facing wall, number of skylights, meter railing), list of parts and clash detection. Liability Typical architects and consulting engineers.
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE 6
Basic definition of Information Levels (Level of Development - LOD)
LOD 350 Corresponding to information level 4 according to Københavns Ejendomme
Definition Object (or structure) is graphically represented as a supplier-specific object with quantities, sizes, dimensions, location and orientation. Objects are detailed at connections with other building components. “Manufacturer/supplier” concerns information about the suppliers products including, data sheet specifications, color codes, warranty period, intervals for maintenance and inspection, lifespan, etc. Possible use Production scheduling, calculation based on production parts, components and production material (m3 concrete, level of reinforcement, formwork, cast-in items), list of parts, clash detection (coordination of design and system deliveries). Liability Typical architects and consulting engineers.
LOD 400 Corresponding to information level 5 according to Københavns Ejendomme
Definition Object (or structure) is graphically represented, possibly as a supplier-specific object with quantities, sizes, dimensions, location and orientation. Objects are detailed for fabrication, assembly, prefabrication, and contains also installation information. Possible use Prefabrication, list of parts and the specific assembly or installation planning. Liability Typical subcontractor or system supplier for prefabrication.
LOD 500
Definition Object’s (or structure’s) quantities, sizes, dimensions, location and orientation is confirmed on site (as built). Possible use Post-calculation for confirmation, registration of deficiencies and part lists. Liability Typical contractor, but can be by the responsible for discipline model.
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - INFRASTRUCTURE 7
Terrain Levelling/gradings Excavation for foundations Excavation for pipes Road and railway Road and railway equipment Dam Existing pipework Drainage
Infrastructure
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - TERRAIN 8
Terrain
LOD 100
LOD Existing terrain is displayed as a 2D surface with a reference point (elevation) which is average for the area. LOI Type Surface name Elevation Layer name
LOD 200
LOD Existing terrain is displayed as a 3D surface, based on manual points measured by total station or rover. Points are measured in height/depth and for each 10/20 meters. LOI Type Surface name Elevation Layer name Classification
LOD 300
LOD Existing terrain is displayed as a 3D surface created by a network of measured points from e.g. an overflight or laser scan. LOI Type Surface name Elevation Layer name Classification
LOD 350
LOD Existing terrain is displayed as a 3D surface created by a network of points measured e.g. an overflight or by laser scanning. Lower layers of soil such as clay, chalk, sand etc. are displayed as independent 3D surfaces with data from measured drill samples. LOI Type Surface name Elevation Layer name Classification
LOD 400
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - LEVELLING/GRADINGS 9
Levelling/gradings
LOD 100
LOD 2D levelling surface. LOI Type Surface name Elevation Layer name
LOD200
LOD Levelling with vertical connection to other surface. LOI Type Surface name Elevation Layer name Classification
LOD 300
LOD Levelling with gradient to other surface. LOI Type Surface name Elevation Layer name Classification Slope signature
LOD 350
LOD Accurate levelling with gradient to other surface. LOI Type Surface name Elevation Layer name Classification Slope signature
LOD 400
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - EXCAVATION FOR FOUNDATIONS 10
Excavation for foundations
LOD 100
LOD Rough excavation as a surface to a fixed level. LOI Type Surface name Elevation Layer name
LOD 200
LOD Rough excavation as a surface to a fixed level with connection to existing terrain. LOI Type Surface name Elevation Layer name Slope signature Classification
LOD 300
LOD Excavation for foundations as a 3D surface with vertical walls. LOI Type Surface name Elevation Layer name Slope signature Classification
LOD 350
LOD Excavation for foundations with sloped walls. LOI Type Surface name Elevation Layer name Slope signature Classification
LOD 400
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - EXCAVATION FOR PIPES 11
Excavation for pipes
LOD 100
LOD Rough excavation along line. LOI Type Elevation Slope Layer name
LOD 200
LOD Rough excavation along 3D object. LOI Type Elevation Slope Layer name Classifiaction
LOD 300
LOD Excavation for pipe with a 3D-plan excavating surface. LOI Type Elevation Slope Layer name Classifiaction Surface name Slope signature Layer, name of surface, level.
LOD 350
LOD Excavation for pipe with excavating surface connected to other surface. LOI Type Elevation Slope Layer name Classification Surface name Slope signature Corridor name
LOD 400
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - ROAD AND RAILWAY 12
Road and railway
LOD 100
LOD Centerline of road and/or railway (2D). LOI Type Dimensions Layer name
LOD 200
LOD 2D surface specifying road and/or railway layout. LOI Type Dimensions Layer name Elevation Classification
LOD 300
LOD Top surface (3D) with connection to terrain. LOI Type Dimensions Layer name Elevation Classification Surface name Slope signature
LOD 350
LOD Top and planum surfaces with gradients to terrain. LOI Type Dimensions Layer name Elevation Classification Surface name Slope signature
LOD 400
LOD Kerb stones, road structure with layouts, ditches with slopes to terrain. LOI Type Dimensions Layer name Elevation Classification Surface name Slope signature Corridor name
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - ROAD AND RAILWAY EQUIPMENT 13
Road and railway equipment
LOD 100
LOD Specification of the location of road- and railway equipment. LOI Type Layer name
LOD 200
LOD Specification, as a volume, of the location of road- and railway equipment. LOI Type Layer name Classification
LOD 300
LOD 3D geometry of road- and railway equipment. LOI Type Layer name Classification
LOD 350
LOD 3D geometry of road- and railway equipment with invisible/hidden geometry such as foundations. LOI Type Layer name Classification
LOD 400
LOD Manufacturer specific details are modelled as joints. LOI Type Layer name Classification
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - DAM 14
Dam
LOD 100
LOD Centre line of dam. LOI Type Dimensions Stationing lines Layer name
LOD 200
LOD Location of where the dam is placed. LOI Type Dimensions Elevations Stationing lines Layer name Classification
LOD 300
LOD Top surface with connection to the existing terrain. LOI Type Dimensions Elevations Stationing lines Layer name Classification Surface name Corridor or grading name Slope signature
LOD 350
LOD Dam structure including the layer structure. – LOI Type Dimensions Elevations Stationing lines Layer name Classification Surface name Corridor or grading name Slope signature
LOD 400
LOD Dam structure including the layer structure and equipment. LOI Type Dimensions Elevations Stationing lines Layer name Classification Surface name Corridor or grading name Slope signature
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - EXISTING PIPEWORK 15
Existing pipework
LOD 100
LOD Approximately location of pipes as 2D lines. LOI Type Dimensions Elevation Slope Layer name
LOD 200
LOD Approximately location of pipes as 3D lines. LOI Type Dimensions Elevation Slope Layer name Classification
LOD 300
LOD Approximate location including slope and size of main distribution route and service pipelines. LOI Type Dimensions Elevation Slope Layer name Classification
LOD 350
LOD Actual dimensions, location and design. Materials, capacity and systems may be represented in the model. LOI Type Dimensions Elevation Slope Layer name Classification
LOD 400
LOD Accurate geometry, including thickness of materials and pipe lengths. Location of valves. Materials, capacity and systems must be represented in the model. LOI Type Dimensions Elevation Slope Layer name Classification
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - DRAINAGE 16
Drainage
LOD 100
LOD Approximately location of pipes as lines. LOI Type Dimensions Layer name
LOD 200
LOD Approximate location and size of main distribution routes and service pipelines. LOI LType Dimensions Layer name Classification Elevation Slope
LOD 300
LOD Approximate location and size of main distribution route and service pipelines with joints. LOI Type Dimensions Layer name Classification Elevation Slope
LOD 350
LOD Actual dimensions, location and design. LOI Type Dimensions Layer name Classification Elevation Slope
LOD 400
LOD Accurate geometry, including thickness of materials and pipe lengths. Materials, capacity and systems must be represented in the Model. LOI Type Dimensions Layer name Classification Elevation Slope Material System name Capacity
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - ARCHITECT 17
Room Roof Light Facade Heavy Facade Light Interior Walls Floor Ceiling Elevator Door Window
Architect
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - ROOM 18
Room
LOD 100
LOD Physical room/space partitioning by function. Door openings (if relevant). Connections. LOI Type Name Function Dimensions (approx.)
LOD 200
LOD The rooms contain: Glazed elements/windows Doors/hatches Stairs Landings Fixed furniture/equipment Sanitary Suspended ceiling LOI Type Name Function Dimensions (approx.) Classification Person capacity Room number Audio requirements Insulation requirements Fire requirements Functional requirements
LOD 300
LOD Suspended ceilings including tiles and floors are added with thickness. LOI Type Name Function Dimensions (approx.) Classification Person capacity Room number Audio requirements Insulation requirements Fire requirements Functional requirements
LOD 350
LOD Suspended ceilings including tiles and floors are added with thickness. LOI Type Name Function Dimensions (approx.) Classification Person capacity Room number Audio requirements Insulation requirements Fire requirements Functional requirements
LOD 400
LOD Suspended ceilings including tiles and floors are added with thickness. LOI Type Name Function Dimensions (approx.) Classification Person capacity Room number Audio requirements Insulation requirements Fire requirements Functional requirements
MT HØJGAARD A/S -BUILDING COMPONENT CATALOGUE - ROOF 19
Roof
LOD 100
LOD The roof's location is represented either by the external surface geometry and shape or by a geometric placeholder with an approximate geometry. LOI Type Dimensions (approx.)
LOD 200
LOD Size, exact shape and location. Approximate location, size and orientation of openings. LOI Type Dimensions Elevations Classification
LOD 300
LOD Building roof in layers (e.g. roofing, insulation and concrete) with external dimensions. Openings for windows, doors and larger ducts are determined. LOI Type Dimensions Elevations Classification Material Structural system U-value Weight
LOD 350
LOD The roof contains, depending on the type, reinforcement. The different layers are modelled. Opening dimensions and locations are accurate. LOI Type Dimensions Elevations Classification Material Structural system U-value Weight Surfaces
LOD 400
LOD All assembly components and details are modelled. It includes internal supporting elements (as laths) or reinforcement details. LOI Type Dimensions Elevations Classification Material Structural system U-value Weight Surfaces Manufacturer/supplier
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - LIGHT FACADE 20
Light Facade
LOD 100
LOD The facade’s location is represented either by the external surface geometry and shape or by a geometric placeholder with an approximate geometry. LOI Type Dimensions (approx.)
LOD 200
LOD Size, exact shape and location. Approximate location of holes and openings. LOI Type Dimensions Elevation Classification
LOD 300
LOD The structure of the roof is modelled in layers (eg. roofing felt, insulation and concrete), external dimensions. Holes for windows, doors and larger penetrations are specified. LOI Type Dimensions Elevation Classification Materia Structure U-value Weight
LOD 350
LOD The roof contains, depending on the type reinforcement. The different layers are modeled. Hole dimensions and location are accurate. LOI Type Dimensions Elevation Classification Materia Structure U-value Weight Surfaces
LOD 400
LOD All assembly components and details are modelled. It includes laths and reglar or reinforcement details. LOI A Type Dimensions Elevation Classification Materia Structure U-value Weight Surfaces Manufacturere/supplier
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - HEAVY FACADE 21
Heavy Facade
LOD 100
LOD The facade’s location is represented either by the external surface geometry (2D-plane) and shape or by a geometric placeholder with an approximate geometry. LOI Type Dimensions (approx.)
LOD 200
LOD 3D geometry that describes the approximate size, shape and location including size and orientation of openings. LOI Type Dimensions Elevation Classification Insulation thickness Bearing/non-bearing
LOD 300
LOD The wall is modelled with layers at precise external dimensions. Openings for windows, doors and larger penetrations are determined. LOI Type Dimensions Elevation Classification Insulation thickness Bearing/non-bearing Material Weight U-value Surfaces
LOD 350
LOD Buildable detailed construction of the wall. The different layers are modelled. Openings’ dimensions and locations are accurate. LOI Type Dimensions Elevation Classification Insulation thickness Bearing/non-bearing Material Weight U-value Surface
LOD 400
LOD All assembly components and details are modelled in 3D. It includes studs, reglar and fittings. LOI Type Dimensions Elevation Classification Insulation thickness Bearing/non-bearing Material Weight U-value Surface Manufacturer/supplier
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - LIGHT INTERIOR WALLS 22
Light Interior Walls
LOD 100
LOD Interior wall’s location is represented either by a surface geometry (2D-planes) and shape or by a geometric placeholder with an approximate geometry. LOI Type Dimensions (approx.)
LOD 200
LOD 3D geometry that describes the approximate dimensions, shape and location. Approximate location, size and orientation of openings and holes. LOI Type Dimensions Elevations Classification Bearing/non-bearing
LOD 300
LOD The structure of the wall is modelled with layers (e.g. insulation and gypsum boards) at precise dimensions. Openings for windows, doors and larger penetrations are exact and fixed. LOI Type Dimensions Elevations Classifications Bearing/non-bearing Material U-value Audio requirements Weight Fire (performance) Sound (performance) Insulation (performance)
LOD 350
LOD Buildable detailed construction of the wall. Walls contain, depending on the type, reinforcement. The different layers are modelled. Openings’ dimensions and locations are accurate. LOI Type Dimensions Elevations Classifications Bearing/non-bearing Material U-value Audio requirements Weight Fire (performance) Sound (performance) Insulation (performance) Surfaces
LOD 400
LOD All assembly components and details are modelled in 3D. This includes internal supporting elements as laths, rules and such as gypsum board, or reinforcement details and connections. LOI Type Dimensions Elevations Classifications Bearing/non-bearing Material U-value Audio requirements Weight Fire (performance) Sound (performance) Insulation (performance) Surfaces Manufacturer/supplier
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - FLOOR 23
Floor
LOD 100
LOD The floor's location is represented either by the surface geometry (2D-planes) and form or through a geometric placeholder with an approximate geometry. LOI Type Dimensions (approx.)
LOD 200
LOD Size, exact shape and location. Approximate location, size and orientation of openings and holes. LOI Type Dimensions Elevation Classification
LOD 300
LOD The construction of floor in layers with precise external dimensions. Openings for larger penetrations are fixed. LOI Type Dimensions Elevation Classification U-value Fire (performance) Sound (performance) Insulation (performance) Material Weight
LOD 350
LOD Buildable detailed structure of the floor. The floor contains, depending on the type, reinforcement. The different layers are modelled. Openings’ dimensions and locations are accurate. LOI Type Dimensions Elevation Classification U-value Fire (performance) Sound (performance) Insulation (performance) Material Weight Surfaces
LOD 400
LOD All assembly components and details are modelled in 3D. This includes possibly internal supporting elements as joists. LOI Type Dimensions Elevation Classification U-value Fire (performance) Sound (performance) Insulation (performance) Material Weight Surfaces Manufacturer/supplier
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - CEILING 24
Ceiling
LOD 100
LOD The ceiling's location is represented either by the surface geometry (2D-planes) and form or through a geometric placeholder with an approximate geometry. LOI Type Dimensions (approx.)
LOD 200
LOD The ceiling is represented by a placeholder with an approximate geometry which, for example, shows a suspended floor at the required height for any installation, and the like. Approximate location, size and orientation of openings / holes (shafts, stairs, etc.) Are indicated. LOI Type Dimensions Elevations Classifications
LOD 300
LOD Construction of suspended ceiling in layers such as insulation and plaster, including approximate openings and details are clarified. Openings for installations and lighting fixtures are listed in the tiled ceiling system. LOI Type Dimensions Elevations Classifications Material System type
LOD 350
LOD The ceiling contains dimensions of ceiling tiles and placement of the suspension system. Openings for installations and lighting fixtures are accurate. LOI Type Dimensions Elevations Classifications Material System type Manufacturer/supplier
LOD 400
LOD Ceiling’s manufacturer-specific details are modelled. Details, joints and profiles are modelled in 3D. LOI Type Dimensions Elevations Classifications Material System type Manufacturer/supplier
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - ELEVATOR 25
Elevator
LOD 100
LOD The location of the elevator shaft is represented either by the surface geometry and shape or through a geometric placeholder with an approximate geometry. LOI Type Dimensions Load Number of floors
LOD 200
LOD The elevator shaft is divided into the shaft itself and the necessary pit and top of the elevator shaft. LOI Type Dimensions Elevation Classification Load Number of floors Electrical (power) requirements
LOD 300
LOD The shaft’s exact dimensions are known. Placement of doors and service hatches are set. LOI Type Dimensions Elevation Classification Load Number of floors Electrical (power) requirements Materials Surfaces
LOD 350
LOD Elevator car is modelled. Doors and external fittings are modelled. LOI Type Dimensions Elevation Classification Load Number of floors Electrical (power) requirements Materials Surfaces Manufacturer/Supplier
LOD 400
LOD The elevator’s manufacturer specific details are modelled. Details, connections and profiles are modelled in 3D. LOI Type Dimensions Elevation Classification Load Number of floors Electrical (power) requirements Materials Surfaces Manufacturer/Supplier
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - DOOR 26
Door
LOD 100
LOD The placement of the door is represented either by surface geometry and shape or by a geometric placeholder with approximate geometry. LOI Type Dimensions Function.
LOD 200
LOD Area of frame and door leaf is separated. Approximate dimensions. LOI Type Dimensions Function Elevation Classification Material The opening direction Suspension direction
LOD 300
LOD Exact dimensions for frame and door leaf are modelled. LOI Type Dimensions Function Elevation Classification Material The opening direction Suspension direction Room number U-value Fire requirements Audio requirements Lock system Fire (performance) Sound (performance) Insulation (performance)
LOD 350
LOD Handles are added. LOI Type Dimensions Function Elevation Classification Material The opening direction Suspension direction Room number U-value Fire requirements Audio requirements Lock system Fire (performance) Sound (performance) Insulation (performance)
LOD 400
LOD Door’s manufacturer specific details are modelled. Details, connections and profiles are modelled. LOI Type Dimensions Function Elevation Classification Material The opening direction Suspension direction Room number U-value Fire requirements Audio requirements Lock system Fire (performance) Sound (performance) Insulation (performance) Manufacturer/supplier
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - WINDOW 27
Window
LOD 100
LOD Placement of the window is represented either by surface geometry (2D-planes) and shape or by a geometric placeholder with approximate geometry. LOI Type Dimensions (approx.)
LOD 200
LOD Area of frame and window is separated. Approximate dimensions. LOI Type Dimensions (approx.) Elevation Classification Material The opening direction Suspension direction
LOD 300
LOD Exact dimensions are modelled in 3D for frame and sash. LOI Type Dimensions Elevation Classification Material The opening direction Suspension direction U-value Audio requirements Lock systems
LOD 350
LOD Handles are added. LOI Type Dimensions Elevation Classification Material The opening direction Suspension direction U-value Audio requirements Lock systems
LOD 400
LOD The window’s manufacturer specific details are modelled. Details, connections and profiles are modelled in 3D. LOI Type Dimensions Elevation Classification Material The opening direction Suspension direction U-value Audio requirements Lock systems Manufacturer/supplier
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - STRUCTURES 28
Foundation, concrete element Foundation, insitu Slab – terrain, insitu Concrete slab, element Concrete slab, in-situ Light slab, steel Concrete Beam, element Concrete Beam, insitu Concrete Wall, element Concrete Wall, insitu Concrete Column, element Concrete Column, insitu Frame Steel Beam Steel Column Staircase, insitu Staircase, element Staircase, steel
Structures
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - FOUNDATION, CONCRETE ELEMENT 29
Foundation, concrete element
LOD 100
LOD The foundation location is represented either by the external surface geometry (in plane) and form or by a geometric placeholder with an approximate geometry. The placeholder may be a base plate that shows the entire foundation. LOI Type Dimensions (approx.)
LOD 200
LOD The foundation is represented as a generic foundation object with an approximate shape, where quantities, size, shape, location and orientation is specified. LOI Type Dimensions Elevation Classification Materials
LOD 300
LOD The foundation has real quantities, dimensions, shape and location. Moreover the orientation. Phasing plus slopes and holes plusrecesses are included. Reinforcement plus building parts and connection details are clarified. LOI Type Dimensions Elevation Classification Materials Reinforcement degree
LOD 350
LOD The foundation contains holes and recesses. Moreover, the insulation modelled. LOI Type Dimensions Elevation Classification Materials Reinforcement Concrete strength Environmental class Blinding layer Concrete, coarse
LOD 400
LOD The foundation contains chamfers, location of embedded partsand main reinforcements appears in the modelle including laps and hooks. LOI Type Dimensions Elevation Classification Materials Reinforcement Concrete strength Environmental class Blinding layer Concrete, coarse Surface Requirements / performance requirements elevation Tolerances Drying Protection maturity Hours density Manufacturer / Supplier
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - FOUNDATION, INSITU 30
Foundation, insitu
LOD 100
LOD The foundation location is represented either by the external surface geometry (in plane) and form or by a geometric placeholder with an approximate geometry. The placeholder may be a base plate that shows the entire foundation. LOI Type Dimensions (approx.)
LOD 200
LOD The foundation is represented as a generic foundation object with an approximate shape, where quantities, size, shape, location and orientation is specified. LOI Type Dimensions Elevation Classification Materials
LOD 300
LOD The foundation has real quantities, dimensions, shape and location. Moreover the orientation. Phasing plus slopes and holes plusrecesses are included. Reinforcement plus building parts are clarified but are not modelled. LOI Type Dimensions Elevation Classification Materials Reinforcement degree Concrete class Weight
LOD 350
LOD The foundation contains holes and recesses. Moreover, the insulation modelled. LOI Type Dimensions Elevation Classification Materials Reinforcement Concrete strength Weight Environmental class Density Blinding layer Concrete, coarse
LOD 400
LOD The foundation contains recesses plus holes, joints and construction joints. Moreover is insulation modelled. LOI Type Dimensions Elevation Classification Materials Reinforcement Concrete strength Weight Environmental class Density Blinding layer Concrete, coarse Surface Requirements / performance requirements Elevation tolerances Drying Protection Maturity Hours Manufacturer / Supplier
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - SLAB – TERRAIN, INSITU 31
Slab – terrain, insitu
LOD 100
LOD The foundation location is represented either by the external surface geometry and form or by a geometric placeholder with an approximate geometry. LOI Type Dimensions (approx.)
LOD 200
LOD The foundation is represented as a generic foundation object with an approximate shape, what concerns quantities, size, shape, location and orientation. LOI Type Dimensions Elevation Classification Materials
LOD 300
LOD The foundation has real quantities, dimensions, and shape plus location and orientation is specified. Recesses/holes >ø500 appears in the geometry. Reinforcement and building details are clarified, but is not modelled. LOI Type Dimensions Elevation Classification Materials
LOD 350
LOD Reinforcement appears in 3D (possible partly) recesses for installations and embedded parts’ location an dimensions are specified. In addition is insulation modelled. LOI Type Dimensions Elevation Classification Materials Main reinforcement Concrete strength Environmental class
LOD 400
LOD Supplier specific details are modelled as assemblies and eg. reinforcement is detailed in 3D, and embedded parts are modelled. LOI Type Dimensions Elevation Classification Materials Reinforcement Surface Requirements / performance requirements Elevation tolerances Drying Protection Maturity Hours Manufacturer / Supplier
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - CONCRETE SLAB, ELEMENT 32
Concrete slab, element
LOD 100
LOD The deck’s locatipon is represented either by exterior surface geometry and shape or by a geometric placeholder with an approximate geometry. LOI Type Dimensions (approx.)
LOD 200
LOD The slab is represented as a generic object with an approximate design in terms of quantity, size, shape, location and orientation. LOI Type Dimensions Elevations Classification Material
LOD 300
LOD The deck has accurate quantities, dimensions and shape - location and orientation is modelled. Recesses/holes >ø500 appears in the geometry. Reinforcement and buildingdetailsare clarified, but do not appear in the model. LOI Type Dimensions Elevations Classification Material
LOD 350
LOD The model is devided forprefabrication. Reinforcement is shown in 3D (possibly partial). Recesses/holes for installations and embedded parts’ accutale location and dimensions are specified. Moreover is insulation modelled. If any exchange beams and flattened steel. LOI Type Dimensions Elevations Classification Material Main reinforcement Concrete strength Environmental class
LOD 400
LOD Manufacturer specific details are modelled, such as connections and eg. reinforcement is detailed in 3D and embedded components are modelled.
LOI Type Dimensions Elevations Classification Material Reinforcement Concrete strength Environment classWeight Surface Requirements / performance requirements Elevation tolerances Drying Protection Maturity Hours Manufacturer / Supplier
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - CONCRETE SLAB, INSITU 33
Concrete slab, insitu
LOD 100
LOD The slab position is represented either by exterior surface geometry and shape or by a geometric placeholder with an approximate geometry. LOI Type Dimensions (approx.)
LOD 200
LOD The slab is represented as a generic object with an approximate design in terms of quantity, size, shape, location and orientation. LOI Type Dimensions Elevations Classification Materials
LOD 300
LOD The deck has accurate quantities, dimensions and shape - location and orientation is illustrated. Recesses/holes >ø500 appears in the geometry. Building part and assembly details are clarified. Exchange beams and flattened steel os modelled. Reinforcement and building details have been clarified, but do not appear in the model. LOI Type Dimensions Elevations Classification Materials
LOD 350
LOD Reinforcement is modelled in 3D (possibly partial). Recesses/holes for installations and embedded parts accurate location and dimensions are modelled. Moreover insulation is modelled. LOI Type Dimensions Elevations Classification Materials Main reinforcement Concrete strength Environment class
LOD 400
LOD Manufacturer specific details are modelled, as connections and eg. reinforcement is detailed in 3D and embedded components are modelled.
LOI Type Dimensions Elevations Classification Materials Reinforcement Concrete strength Environment class Surface Requirements / performance requirements Elevation tolerances Drying Protection Maturity Hours Reinforced joints Concrete joints Manufacturer / Supplier
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - LIGHT SLAB, STEEL 34
Light slab, steel
LOD 100
LOD The deck’s locations is represented either by an exterior surface geometry and shape or by a geometric placeholder with an approximate geometry. LOI Type Dimensions (approx.)
LOD 200
LOD Main beams location and orientation including categorization of beams’ top and bottom are modeled plus approximate dimensions. LOI Type Dimensions (approx.) Elevations Classifications Materials
LOD 300
LOD Beam sizes are clarified and their mutual distances and supports are defined. Recesses/holes > ø500 appears within the geometry. LOI Type Dimensions Elevations Classifications Materials Steel strength
LOD 350
LOD Actual and final beam profiles with the exact location and dimensions are modeled including bigger bolts. LOI Type Dimensions Elevations Classifications Materials Steel strength Fire requirements Corrosion protection
LOD 400
LOD The model contains all the details about the steel slab including plates, bolts, connections etc. LOI Type Dimensions Elevations Classifications Materials Steel strength Fire requirements Corrosion protection Installation Tolerance adhesive Anchor Semi / drilling depth + type Manufacturer / Supplier
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - CONCRETE BEAM, ELEMENT 35
Concrete Beam, element
LOD 100
LOD The beam position is represented either by the external surface geometry and form or as a geometric placeholder with an approximate geometry. LOI Type Dimensions (approx.)
LOD 200
LOD The beam is represented as a generic beam object with an approximate design in terms of quantities, size and shape plus location and orientation is given. LOI Type Dimensions Elevations Classification Material
LOD 300
LOD The beam has actual quantities, dimensions and shape - location and orientation is specified. Tampering and slopes plus holes/recesses are modelled. Reinforcement and building details are clarified. LOI Type Dimensions Elevations Classification Material
LOD 350
LOD The beam includes chamfers, location of embedded components, joints and casting joints. Moreover recesses and insulations is modelled. LOI Type Dimensions Elevations Classification Material Main reinforcement Concrete strength Environmental class
LOD 400
LOD The beam is divided for prefabrication. Reinforcement is detailed and includs laps and hooks. LOI Type Dimensions Elevations Classification Material Reinforcement Concrete strength Environmental class Surface Requirements / performance requirements Elevation tolerances Drying protection Maturity hours Reinforced joints Concrete joints Manufacturer / Supplier
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - CONCRETE BEAM, INSITU 36
Concrete Beam, insitu
LOD 100
LOD The beam position is represented either by the external surface geometry and form or as a geometric placeholder with an approximate geometry. LOI Type Dimensions (approx.)
LOD 200
LOD The beam is represented as a generic beam object with an approximate design in terms of quantities, size and shape plus location and orientation is given. LOI Type Dimensions Elevations Classification Material
LOD 300
LOD The beam has actual quantities, dimensions and shape - location and orientation is specified. Tampering and slopes plus holes/recesses are modelled. Reinforcement and building details are clarified. LOI Type Dimensions Elevations Classification Material
LOD 350
LOD The beam includes chamfers, location of embedded components, joints and casting joints. Moreover recesses and insulations is modelled. Moreover holes for reinforced joints are modeled. LOI Type Dimensions Elevations Classification Material Main reinforcement Concrete strength Environmental class
LOD 400
LOD Reinforcement is detailed and includs laps and hooks. LOI Type Dimensions Elevations Classification Material Reinforcement Concrete strength Environmental class Surface Requirements / performance requirements Elevation tolerances Drying protection Maturity hours Manufacturer / Supplier
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - CONCRETE WALL, ELEMENT 37
Concrete Wall, element
LOD 100
LOD The wall's location is represented either by a surface or by a geometric placeholder with an approximate geometry. LOI Type Dimensions (approx.)
LOD 200
LOD The wall is represented as a generic object with an approximate design in terms of quantity, size, shape, location and orientation. Openings (doors/windows/shaft/etc.) appears. LOI Type Dimensions Elevations Classification
LOD 300
LOD The wall has accurate quantities, dimensions and shape - location and orientation is specified. Holes for beams, doors and windows plus holes for installations >ø350 appears. Building details are clarified. LOI Type Dimensions Materials Elevations Classification
LOD 350
LOD The model is divided for prefabrication. Recesses/holes for installations >ø150 plus embedded componets accurate locations and dimensions are modelled. Building details are clarified. Moreover insulation is modelled. LOI Type Dimensions Materials Elevations Classification Main reinforcements Concrete strength Environmental class
LOD 400
LOD Manufacturer specific details are modelled as connections and eg. reinforcement is detailed in 3D. LOI Type Dimensions Materials Elevations Classification Reinforcements Concrete strength Environmental class Weight Surface Requirements / performance requirements Elevations tolerances Drying protection Maturity hours Reinforced joints Concrete joints Manufacturer / Supplier
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - CONCRETE WALL, INSITU 38
Concrete Wall, insitu
LOD 100
LOD The wall's location is represented either by a surface or by a geometric placeholder with an approximate geometry. LOI Type Dimensions (approx.)
LOD 200
LOD The wall is represented as a generic object with an approximate design in terms of quantity, size, shape, location and orientation. Openings (doors/windows/shaft/etc.) appears. LOI Type Dimensions Elevations Classification
LOD 300
LOD The wall has accurate quantities, dimensions and shape - location and orientation is specified. Holes for beams, doors and windows plus holes for installations >ø350 appears. Building details are clarified. LOI Type Dimensions Materials Elevations Classification
LOD 350
LOD Recesses/holes for installations >ø150 plus embedded componets accurate locations and dimensions are modelled. Building details are clarified. Moreover insulation is modelled. LOI Type Dimensions Materials Elevations Classification Main reinforcements Concrete strength Environmental class
LOD 400
LOD Manufacturer specific details are modelled as connections and eg. reinforcement is detailed in 3D. LOI Type Dimensions Materials Elevations Classification Reinforcement Concrete strength Concrete class Environmental class Surface Requirements / performance requirements Elevations tolerances Drying protection Maturity hours Manufacturer / Supplier
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - CONCRETE COLUMN, ELEMENT 39
Concrete Column, element
LOD 100
LOD The column's location is represented by either a line or by a geometric placeholder with an approximate geometry. LOI Type
LOD 200
LOD The column is represented as a generic column object with approximate quantities, size and shape. Location and orientation is shown. LOI Type Dimensions (approx) Elevations Classification Main reinforcement
LOD 300
LOD Actual quantities, size and shape including holes, location and orientation. Brackets appears within the geometry. Building details are clarified. LOI Type Dimensions Elevations Classification Reinforcement degree Material
LOD 350
LOD The column contains recesses with precise dimensions and location. Depending on type: chamfers, location of embedded components, joints and construction joints or end plates, brackets, stiffening plates and the like. LOI Type Dimensions Elevations Classification Main reinforcement Material Concrete strength Environmental class
LOD 400
LOD Manufacturer Specific details are modeled as chamfers, joints and eg. reinforcement is detailed in 3D and embedded components are modeled. LOI Type Dimensions Elevations Classification Reinforcement Material Concrete strength Environmental class Surface Requirements / performance requirements Elevation tolerances Drying Protection Maturity hours Manufacturer / Supplier
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - CONCRETE COLUMN, INSITU 40
Concrete Column, insitu
LOD 100
LOD The column's location is represented by either a line or by a geometric placeholder with an approximate geometry. LOI Type
LOD 200
LOD The column is represented as a generic column object with approximate quantities, size and shape. Location and orientation is shown. LOI Type Dimensions (approx) Elevations Classification
LOD 300
LOD Actual quantities, size and shape including holes, location and orientation. Brackets appears within the geometry. Building details are clarified. LOI Type Dimensions Elevations Classification Main reinforcement
LOD 350
LOD The column contains recesses with precise dimensions and location. Depending on type: chamfers, location of embedded components, joints and construction joints or end plates, brackets, stiffening plates and the like. LOI Type Dimensions Elevations Classification Main reinforcement Material Concrete strength Environmental class
LOD 400
LOD Manufacturer Specific details are modeled as chamfers, joints and eg. reinforcement is detailed in 3D and embedded components are modeled. LOI Type Dimensions Elevations Classification Main reinforcement Material Concrete strength Environmental class Weight Surface Requirements / performance requirements Elevation tolerances Drying Protection Maturity hours Reinforced joints Concrete joints Manufacturer / Supplier
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - FRAME 41
Frame
LOD 100
LOD The frame's location is represented by either a line or through a geometric placeholder with an approximate geometry. LOI Type Material (approx.)
LOD 200
LOD The framework is represented as a generic object with approximate quantities, size and shape. Location and orientation is shown. LOI Type Dimensions Elevation Classification Material
LOD 300
LOD The frame is represented as a generic object of actual quantities, size and shape. Location and orientation is shown. Brackets is shown in the geometry. Building detail are clarified. LOI Type Dimensions Elevations Classification Material
LOD 350
LOD The frame contains recesses with precise dimensions and location inkl. Fire protection. Depending on type: chamfers, location of embedded parts, joints and construction joints or end plates, brackets, stiffening plates and the like. Material of the assembly components are shown at joints where used. LOI Type Dimensions Elevations Classification Material Fire safety Steel strength Weight
LOD 400
LOD Manufacturer specific details are modelled, eg. connections and reinforcement is detailed in 3D and cast-in items are modelled. LOI Type Dimensions Elevations Classification Material Fire safety Steel strength Weight Fire protection Corrosion protection Manufacturer/supplier
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - STEEL BEAM 42
Steel Beam
LOD 100
LOD The beam position is represented either by the external surface geometry and form or by a geometric placeholder with an approximate geometry. LOI Type Dimensions (approx.)
LOD 200
LOD The beam is represented as a generic beam object with an approximate design in terms of quantities, size and shape. Location and orientation is given. LOI Type Dimensions Elevations Classification Material
LOD 300
LOD The beam has real quantities, dimensions and shape - location and orientation is specified. Holes/recesses for installations are modelled. Building detaila are clarified. LOI Type Dimensions Elevations Classification Material Fire requirements
LOD 350
LOD The beam includes end plates and brackets as well as body stiffening and fire insulation. Assembling details and holes for reinforced joints has been clarified. LOI Type Dimensions Elevations Classification Material Fire requirements Surface treatment Steel Strength
LOD 400
LOD The beam is divided for prefabrication. LOI Type Dimensions Elevations Classification Material Fire requirements Surface treatment Steel Strength Corrosion protection Mounting Tolerance Adhesive Anchor Semi / drilling depth Manufacturer/supplier
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - STEEL COLUMN 43
Steel Column
LOD 100
LOD The column position is represented either by the external surface geometry and form or by a geometric placeholder with an approximate geometry. LOI Type Dimensions (approx.)
LOD 200
LOD The column is represented as a generic column object with an approximate design in terms of quantities, size and shape. Location and orientation is given. LOI Type Dimensions Elevations Classification Material
LOD 300
LOD The column has real quantities, dimensions and shape - location and orientation is specified. If any, holes/recesses for installations are modelled. Building detaila are clarified. LOI Type Dimensions Elevations Classification Material Fire requirements
LOD 350
LOD The column includes end plates and brackets as well as body stiffening and fire insulation. Assembling details and holes for reinforced joints has been clarified. LOI Type Dimensions Elevations Classification Material Fire requirements Surface treatment Steel Strength
LOD 400
LOD The column is divided for prefabrication. LOI Type Dimensions Elevations Classification Material Fire requirements Surface treatment Steel Strength Corrosion protection Mounting Tolerance Adhesive Anchor Semi / drilling depth Manufacturer/supplier
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - STAIRCASE, INSITU 44
Staircase, insitu
LOD 100
LOD The location of the staircase is represented by a geometric placeholder with an approximate geometry. LOI Type Dimensions (approx.)
LOD 200
LOD The staircase is represented by a generic object with a simplified specification of the stair steps and landing locations. LOI Type Dimensions (approx.) Elevation Classifikation Material
LOD 300
LOD The staricase is modelled specifying the exact location og the stair steps and landing including greater support elements and with an indication of secondary structural elements. LOI Type Dimensions Elevation Classifikation Material
LOD 350
LOD The staircase is divided for prefabrication. Holes/recesses for installations are modeled. LOI Type Dimensions Elevation Classifikation Material Surface requirements Main reinforcement
LOD 400
LOD All staircase elemnts are specified. LOI Type Dimensions Elevation Classifikation Material Surface requirements Reinforcement Manufacturer/supplier
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - STAIRCASE, ELEMENT 45
Staircase, element
LOD 100
LOD The location of the staircase is represented by a geometric placeholder with an approximate geometry. LOI Type Dimensions (approx.)
LOD 200
LOD The staircase is represented by a generic object with a simplified specification of the stair steps and landing locations. LOI Type Dimensions (approx.) Elevations Classifikation Material
LOD 300
LOD The staricase is modelled specifying the exact location og the stair steps and landing including greater support elements. LOI Type Dimensions Elevations Classifikation Material
LOD 350
LOD The staircase is divided for prefabrication. Holes/recesses for installations are modeled and secondary structural elements are specified. LOI Type Dimensions Elevation Classifikation Material Surface requirements Main reinforcement
LOD 400
LOD All staircase elemnts are specified. LOI Type Dimensions Elevation Classifikation Material Surface requirements Reinforcement Manufacturer/supplier
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - STAIRCASE, STEEL 46
Staircase, steel
LOD 100
LOD The location of the staircase is represented by a geometric placeholder with an approximate geometry. LOI Type Dimensions (approx.)
LOD 200
LOD The staircase is represented by a generic object with a simplified specification of the stair steps and landing locations. LOI Type Dimensions (approx.) Elevations Classifikation Material
LOD 300
LOD The staricase is modelled specifying the exact location og the stair steps and landing including greater support elements. LOI Type Dimensions Elevations Classifikation Material
LOD 350
LOD The staircase is divided for prefabrication. Holes/recesses for installations are modeled and secondary structural elements are specified. LOI Type Dimensions Elevations Classifikation Material Fire requirements Steel strength Corrosion protection
LOD 400
LOD All staircase elemnts are specified. LOI Type Dimensions Elevations Classifikation Material Fire requirements Steel strength Corrosion protection Surface treatment Mounting tolerance Adhesive anchor Semi/drilling depth Manufacturer/supplier
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - INSTALLATIONS 47
Utility Pipe services, terrain Water-carrying installations (heating, drainage (rainwater/sewage), domestic water, cooling and sprinkling) Air born installations Ventilation Electricity Low voltage (CTS & IT and data communication, security, personal security access security)
Installations
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - UTILITY 48
Utility
LOD 100
LOD The main routing trays are represented by a geometric placeholder with an approximate geometry or schematic diagrams. Supply plants represents: cooling plant, heating plant, sprinkler plant, ventilations plant, distributions center main electrical panels and swichtboards incl. service agreements. LOI Type Dimensions (approx.) Consumption
LOD 200
LOD Aapproximate location and size of the main and secondary installations routes . Approximate space requirements for access must be represented in the model. Approximate location of exchangers, boilers, pumps, tankts etc. LOI Type Dimensions (approx.) Elevations Classification Comsumptions System name
LOD 300 3
LOD Actual geometry, design and location of main installations routes including needed spaces for service acces incl. space need for suspension including type, supports, etc. Insulations is modelled. Connections and aggregate types (counter flow, rotary or plate heat exchanger) are modelled. LOI Type Dimensions (approx.) Elevations Classification Comsumptions System name Materials
LOD 350
LOD Detailed geometry with actual sizes, location, design, access requirement for installations including suspensions and supports. LOI Type Dimensions (approx.) Elevations Classification Comsumptions System name Materials Manufacturer/supplier
LOD 400
LOD Supplier-specific connections and details are modelled in 3D. Servies areas are modelled. LOI Type Dimensions (approx.) Elevations Classification Comsumptions System name Materials Manufacturer/supplier
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - PIPE SERVICES, TERRAIN 49
Pipe services, terrain
LOD 100
LOD The main routing paths are represented by a geometric placeholder with an approximate geometry or as schematic diagrams. LOI Type Dimensions Consumption(approx.)
LOD 200
LOD Generic layout, approximate location and size of the main and secondary installationtion routes including valveslines. Approximate space requirements for access are represented in the model. Locations of wall and slap penetrations (fire and audio seling). LOI Type Dimensions (approx.) Elevations Classification System name Performance requirements
LOD 300
LOD Actual dimensions, locations, design of main and secondary installations routes. . Material thichkness of pipes and valves locations er modelled. LOI Type Dimensions Elevations Classification System name Performance requirements Materials
LOD 350
LOD Detailed geometry. LOI Type Dimensions Elevations Classification System name Performance requirements Materials Capacity
LOD 400
LOD Supplier-specific connections and details are modelled in 3D. LOI Type Dimensions Elevations Classification System name Performance requirements Materials Capacity Manufacturer /supplier
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - WATER-CARRYING INSTALLATIONS (HEATING, DRAINAGE (RAINWATER/SEWAGE), DOMESTIC WATER, COOLING AND SPRINKLING) 50
Water-carrying installations (heating, drainage (rainwater/sewage), domestic water, cooling and sprinkling)
LOD 100
LOD The main installation routing paths are represented by a geometric placeholder with an approximate geometry or as schematic diagrams. LOI Type Dimensions (approx.) System name
LOD 200
LOD Approximate location and size of the main and secondary pipes. Approximate space (shafts)requirements are represented in the model. Location of wall and slap penetrations (fire and sound sealing). LOI Type Dimensions (approx.) Elevations Classification System name
LOD 300
LOD Pipe dimensions and bends are determined including locations and design with needed slope. Free space for pipes including insulation is modelled. Pumps, cleaning hatches, blancing valves, radioators, sanitary, etc. Sprinnklers and other components in the suspended ceiling are modelled. LOI Type Dimensions Elevations Klassification System name Materials
LOD 350
LOD Detailed geometry, with actual sizes, location and design. Fittings, bends and all types of valves, fasteners and pipes including thickness. LOI Type Dimensions Elevations Klassification System name Materials Manufacturer/supplier
LOD 400
LOD Supplier-specific connections and details are modelled in 3D plus suspension, brackets and supports. LOI Type Dimensions Elevations Klassification System name Materials Manufacturer/supplier
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - AIR BORN INSTALLATIONS 51
Air born installations
LOD 100
LOD The main installation routing paths are represented by a geometric placeholder with an approximate geometry or as schematic diagrams. LOI Type Dimensions (approx.) System name
LOD 200
LOD Approximate location and size of the main and secondary pipes. Approximate space (shafts)requirements are represented in the model. Location of wall and slap penetrations (fire and sound sealing). LOI Type Dimensions (approx.) Elevations Classification System name
LOD 300
LOD Pipe dimensions and bends are determined including locations and design. Free space and clearance and fire insulations at pipes are modelled. Fittings multi boxes, balancing valves, etc. Alle components in the suspended ceiling are modelled. LOI Type Dimensions Elevations Classification System name Materials
LOD 350
LOD Detailed geometry, with actual sizes, location and design. Fittings, bends and all types of valves, fasteners and pipes including thickness. LOI Type Dimensions Elevations Classification System name Materials Manufacturer/supplier
LOD 400
LOD Supplier-specific connections and details are modelled in 3D plus suspension, brackets and supports. LOI Type Dimensions Elevations Classification System name Materials Manufacturer/supplier
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - VENTILATION 52
Ventilation
LOD 100
LOD Main routing paths represented by a geometric placeholder with an approximate geometry or as schematic diagrams. LOI Type Dimensions (approx.) System name
LOD 200
LOD Approximate location and size of the main and secondary ducts. Approximate space (shaft) requirements are represented in model. Locations of wall and floor penetrations (fire and audio sealing). LOI Type Dimensions (approx.) Elevations Classification System name
LOD 300
LOD Duct dimensions are accurate including location and desing. The system includes insulation, fixtures and fittings that all are modelled. LOI Type Dimensions Elevations Classification System name Air flow
LOD 350
LOD Detailed geometry of all duct routes with actual sizes, locations and design, space requirements for access needs for both ducts and dampers, silencers and fittings. LOI Type Dimensions Elevations Classification System name Air flow Manufacturer/supplier
LOD 400
LOD Supplier-specific connections and details are modelled in 3D. Suspensions and supports. LOI Type Dimensions Elevations Classification System name Air flow Manufacturer/supplier
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - ELECTRICITY 53
Electricity
LOD 100
LOD Main cable trays, blackboards and approximate dimensions, location and design. Approximate space requirements for service access and clearances. LOI Type Dimensions (approx.)
LOD 200
LOD Cable tray routing and location of blackboards, Dimensions location and design is detailed. Approximate space requirements for acces to black boards. Location og wall and slap penetrations (fire and sound sealing) LOI Type Dimensions Elevation Classification System name
LOD 300
LOD Actual dimensions, location including bends and fittings. Location and dimensions of fixtures and switches plus mounting boxes and draft tube in concrete elements. Location of visible secondary cable trays including all relevant low voltage components. LOI Type Dimensions Elevation Classification System nameMaterials
LOD 350
LOD Detailed geometry with actual sizes, location, design including suspension type and its space requirements. LOI Type Dimensions Elevation Classification System name Materials Manufacturer/supplier
LOD 400
LOD Supplier-specific connections and details are modelled in 3D. Suspension, brackets and supports are modeled LOI Type Dimensions Elevation Classification System name Materials Manufacturer/supplier
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - LOW VOLTAGE (CTS & IT AND DATA COMMUNICATION, SECURITY, PERSONAL SECURITY ACCESS SECURITY) 54
Low voltage (CTS & IT and data communication, security, personal security access security)
LOD 100
LOD Approximate space requirements for service access of boards / panels incl. clearances represented by a deputy. LOI Type Dimensions (approx.)
LOD 200
LOD Low voltage components in the suspended ceiling is represented in the model. Switchboards and switches are specific (technical rooms and shaft) space requirements for access to boeards etc. LOI Type Dimensions (approx.) Elevation Classification System name
LOD 300
LOD All low voltage components are modelled, both in the cerilings, walls and floors. The location and size are specified med exact dimensions in the model. LOI Type Dimensions Elevation Classification System name
LOD 350
LOD All low voltage components are modelled, both in the cerilings, walls and floors. The location and size are specified med exact dimensions in the model. LOI Type Dimensions Elevation Classification System name Manufacturer/supplier
LOD 400
LOD All low voltage components are modelled, both in the cerilings, walls and floors. The location and size are specified med exact dimensions in the model. LOI Type Dimensions Elevation Classification System name Materials Manufacturer/supplier
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - SAMPLE OF MODEL PROGRESSION SPECIFICATION – MPS 55
Sample of Model Progression Specification – MPS
Sample of the Model Progression Specification - MPS in relation to milestones. LOD acc. to "Building Component Catalogue with information levels (LOD)". The plan must be adapted for the indicidual project, and the following are only filled ind as an example.
DIS
CIP
LIN
E
OBJECT TYPE
PRELIMINARY PROJECT PHASE
DETAILED DESIGN PHASE
SUPPLIER MODEL
AS BUILT AND OPERATIONAL
PHASE*
GEO
MET
RY
PRO
PERTI
ES
GEO
MET
RY
PRO
PERTI
ES
GEO
MET
RY
PRO
PERTI
ES
GEO
MET
RY
PRO
PERTI
ES
LOD LOI LOD LOI LOD LOI LOD LOI
INFR
ASTR
UCTU
RE
Terrain 200 0 300 300 300 0 * *
Levelling/gradings 200 0 300 0 350 0 * *
Excavation for foundations 200 0 350 0 0 0 * *
Excavation for pipes 200 0 300 0 350 0 * *
Road and railway 300 0 350 0 400 0 * *
Road and railway equipment
200 0 300 0 350 0 * *
Dam 200 0 350 0 400 0 * *
Existing pipework 200 0 300 350 0 0 * *
Drainage 200 0 300 0 350 0 * *
*) To be agreed upon with the client at the project start-up
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - SAMPLE OF MODEL PROGRESSION SPECIFICATION – MPS 56
Sample of Model Progression Specification – MPS D
ISCIP
LIN
E
OBJECT TYPE
PRELIMINARY PROJECT PHASE
DETAILED DESIGN PHASE
SUPPLIER MODEL
AS BUILT AND OPERATIONAL
PHASE*
GEO
MET
RY
PRO
PERTI
ES
GEO
MET
RY
PRO
PERTI
ES
GEO
MET
RY
PRO
PERTI
ES
GEO
MET
RY
PRO
PERTI
ES
LOD LOI LOD LOI LOD LOI LOD LOI
ARCH
ITEC
T
Room 200 200 300 300 400 400 * *
Roof 200 300 350 350 400 400 * *
Light façade 200 300 350 350 400 400 * *
Heavy façade 200 300 350 350 0 0 * *
Light Interior Walls 200 300 300 300 0 0 * *
Floor 200 300 300 300 0 0 * *
Ceiling 200 300 350 350 0 0 * *
Elevator 200 300 200 300 400 400 * *
Door 200 300 200 400 400 400 * *
Window 200 300 350 350 400 400 * *
*) To be agreed upon with the client at the project start-up
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - SAMPLE OF MODEL PROGRESSION SPECIFICATION – MPS 57
Sample of Model Progression Specification – MPS D
ISCIP
LIN
E
OBJECT TYPE
PRELIMINARY PROJECT PHASE
DETAILED DESIGN PHASE
SUPPLIER MODEL
AS BUILT AND OPERATIONAL
PHASE*
GEO
MET
RY
PRO
PERTI
ES
GEO
MET
RY
PRO
PERTI
ES
GEO
MET
RY
PRO
PERTI
ES
GEO
MET
RY
PRO
PERTI
ES
LOD LOI LOD LOI LOD LOI LOD LOI
STR
UCTU
RES
Foundation, conc. element 200 300 300 300 0 0 * *
Foundation, insitu 200 300 300 300 0 0 * *
Slap – terrain, insitu 200 300 300 300 350 400 * *
Concrete slap, element 200 300 300 300 350 400 * *
Concrete slap, insitu 200 300 300 300 350 400 * *
Light slap, steel 200 300 300 300 350 400 * *
Concrete beam, element 200 300 300 300 350 400 * *
Concrete beam, insitu 200 300 300 300 350 400 * *
Concrete wall, element 200 300 300 300 350 400 * *
Concrete wall, insitu 200 300 300 300 350 400 * *
Concrete column, element 200 300 300 300 350 400 * *
Concrete column, insitu 200 300 300 300 350 400 * *
Frame 200 300 300 300 400 400 * *
Steel beam 200 300 300 300 350 400 * *
Steel column 200 300 300 300 350 400 * *
Staircase, insitu 200 300 300 300 350 400 * *
Staircase, element 200 300 300 300 350 400 * *
Staircase, steel 200 300 300 300 350 400 * *
*) To be agreed upon with the client at the project start-up
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - SAMPLE OF MODEL PROGRESSION SPECIFICATION – MPS 58
Sample of Model Progression Specification – MPS
DIS
CIP
LIN
E
OBJECT TYPE
PRELIMINARY PROJECT PHASE
DETAILED DESIGN PHASE
SUPPLIER MODEL
AS BUILT AND OPERATIONAL
PHASE*
GEO
MET
RY
PRO
PERTI
ES
GEO
MET
RY
PRO
PERTI
ES
GEO
MET
RY
PRO
PERTI
ES
GEO
MET
RY
PRO
PERTI
ES
LOD LOI LOD LOI LOD LOI LOD LOI
INSTA
LLATI
ON
S
Utility 200 300 200 300 350 400 * *
Pipe services, terrain 200 300 300 350 0 0 * *
Water-carrying installations 200 300 300 350 0 0 * *
Air born installations 200 300 300 350 0 0 * *
Ventilation 200 300 200 350 400 0 * *
Electricity 200 300 300 350 0 0 * *
Low voltage 200 300 300 350 0 0 * *
*) To be agreed upon with the client at the project start-up