The S•C•A•T Europe System offers:
Single components up to complete configured sets
All Components made of electro conductive PE-HD
High flexibility / modular system Quite handy Pipeline systems as a project solution Special solutions on request
![Page 3: Built -in Solutions Safe fluid waste disposal for chemical laboratories Dave Withee](https://reader036.vdocument.in/reader036/viewer/2022070422/568164fc550346895dd7682d/html5/thumbnails/3.jpg)
The Safety Specialist.
www.scat-europe.com
These three basic versions are possible :
■Funnel on tabletop ■ Funnel in Backwall ■ HPLC Waste connection on
tabletop
![Page 4: Built -in Solutions Safe fluid waste disposal for chemical laboratories Dave Withee](https://reader036.vdocument.in/reader036/viewer/2022070422/568164fc550346895dd7682d/html5/thumbnails/4.jpg)
The Safety Specialist.
www.scat-europe.com
Filling Units Electro conductive funnel with removable
sieve Useable for small and larger quantities of
liquid waste Free turnable thread
Hinged lid for closing
or alternatively ...
![Page 5: Built -in Solutions Safe fluid waste disposal for chemical laboratories Dave Withee](https://reader036.vdocument.in/reader036/viewer/2022070422/568164fc550346895dd7682d/html5/thumbnails/5.jpg)
The Safety Specialist.
www.scat-europe.com
Filling Units SCAT SafetyCaps for connecting
capillaries and / or tubings Gastight connections Free turnable thread
Also useable outside the fume hood!
Available in various designs
or…
![Page 6: Built -in Solutions Safe fluid waste disposal for chemical laboratories Dave Withee](https://reader036.vdocument.in/reader036/viewer/2022070422/568164fc550346895dd7682d/html5/thumbnails/6.jpg)
The Safety Specialist.
www.scat-europe.com
Filling Units Useage of an adapter to connect multiple
SafetyCaps on one desktop mount
In this way, several HPLC systems are collectable in one waste system
![Page 7: Built -in Solutions Safe fluid waste disposal for chemical laboratories Dave Withee](https://reader036.vdocument.in/reader036/viewer/2022070422/568164fc550346895dd7682d/html5/thumbnails/7.jpg)
The Safety Specialist.
www.scat-europe.com
The Desktop Mount GL45 thread above the table top
G ½“ thread underneath the table top
Easy to mount in the table top
If the system should not be used, the desktop mount can be closed with a standard cap GL45
or…..
![Page 8: Built -in Solutions Safe fluid waste disposal for chemical laboratories Dave Withee](https://reader036.vdocument.in/reader036/viewer/2022070422/568164fc550346895dd7682d/html5/thumbnails/8.jpg)
The Safety Specialist.
www.scat-europe.com
The backwall mount GL45 thread in the backwall
G ½“ thread behind the backwall
More free space on the table top
If the system should not be used, the desktop mount can be closed with a standard cap GL45
The connection to a tubing will be build by an adapter (G1/2“ to GL25) for both mount parts
![Page 9: Built -in Solutions Safe fluid waste disposal for chemical laboratories Dave Withee](https://reader036.vdocument.in/reader036/viewer/2022070422/568164fc550346895dd7682d/html5/thumbnails/9.jpg)
The Safety Specialist.
www.scat-europe.com
Pipeline Systems Pipeline systems are modular configurable
Thread adapter
SafetyWasteCaps in different thread sizes
Also many different SafetyCaps to fix capillaries on the desktop mount, (customized set-up)
![Page 10: Built -in Solutions Safe fluid waste disposal for chemical laboratories Dave Withee](https://reader036.vdocument.in/reader036/viewer/2022070422/568164fc550346895dd7682d/html5/thumbnails/10.jpg)
The Safety Specialist.
www.scat-europe.com
The tubing
Flexible PE-HD EL tubing
Tubing with plain ends and compression fittings or with connecting nut
Available in different lengths Also available in PFA
![Page 11: Built -in Solutions Safe fluid waste disposal for chemical laboratories Dave Withee](https://reader036.vdocument.in/reader036/viewer/2022070422/568164fc550346895dd7682d/html5/thumbnails/11.jpg)
The Safety Specialist.
www.scat-europe.com
Shut-off Valve
Prevents leakage out of the tubing during the container change
![Page 12: Built -in Solutions Safe fluid waste disposal for chemical laboratories Dave Withee](https://reader036.vdocument.in/reader036/viewer/2022070422/568164fc550346895dd7682d/html5/thumbnails/12.jpg)
The Safety Specialist.
www.scat-europe.com
Low Ceiling Valve
Angle to reduce the installation height, in the case that the container is inside a safety cupboard
prevent the collision between the tubing and saftey cupboard
![Page 13: Built -in Solutions Safe fluid waste disposal for chemical laboratories Dave Withee](https://reader036.vdocument.in/reader036/viewer/2022070422/568164fc550346895dd7682d/html5/thumbnails/13.jpg)
The Safety Specialist.
www.scat-europe.com
SafetyWasteCap S60 SafetyWasteCap from PE-HD-EL
integrated electronic level control
Atex compliant acc. TÜV Statement of conformity : Ex II 2 G Ex ia IIB T6
Free turnable thread
With one tubing connection GL25
Connection for venting tube or exhaust filter
![Page 14: Built -in Solutions Safe fluid waste disposal for chemical laboratories Dave Withee](https://reader036.vdocument.in/reader036/viewer/2022070422/568164fc550346895dd7682d/html5/thumbnails/14.jpg)
The Safety Specialist.
www.scat-europe.com
The Exhaust Filter
If there is no air ventilation around the waste container you can use an exhaust filter
Solvent vapors are held back effectively to protect the employees and environment
![Page 15: Built -in Solutions Safe fluid waste disposal for chemical laboratories Dave Withee](https://reader036.vdocument.in/reader036/viewer/2022070422/568164fc550346895dd7682d/html5/thumbnails/15.jpg)
The Safety Specialist.
www.scat-europe.com
Funnel for direct disposal into the container
Integrated level control
With 37,5 cm overall height suitable for the mostly common safety cupboards
Funnel set to use inside the safety cupboard
![Page 16: Built -in Solutions Safe fluid waste disposal for chemical laboratories Dave Withee](https://reader036.vdocument.in/reader036/viewer/2022070422/568164fc550346895dd7682d/html5/thumbnails/16.jpg)
The Safety Specialist.
www.scat-europe.com
I protect myself.With SCAT Safety Products.
Thank you very much for your attention
If you have questions, please contact:Dave Withee Cell 920.737.8477