Download - CableGlands[1]
-
5/27/2018 CableGlands[1]
1/12
International Metallic
Cable Gland Solutions
-
5/27/2018 CableGlands[1]
2/12
For more than 100 years, companies have come to rely on
Cooper Crouse-Hinds for value they can trust to grow theirbusiness. Our comprehensive offering of electrical products
meet customer application requirements in the most
demanding industrial and commercial environments
worldwide.
Our customer-first commitment to combine premium quality
and reliability with superior technical support successfully
minimizes downtime, reduces repair incidence, and improves
safety and productivity. Every product we develop and every
solution we engineer is clearly focused on lowering our
customers total cost of ownership.
Global termination solutions movingpower and signals in the worlds mostdemanding environments
From the deserts of
Africa to the icy
waters of the North
Sea, the world turns
to Cooper Crouse-
Hinds for its
complete gland
solutions. Our cable
glands are used in
industrial and
commercial
applications
throughout the world
engineering safety
and productivity in
the most severe
environmental
conditions.
Cooper Crouse-Hinds global offering provides a termination
solution for virtually every cable type used in hazardous and
industrial environments. These glands are designed for strict
adherence to global specifications meeting North American
and international codes and standards, including NEC, CEC,
ATEX, IECEx, and regional certifications.
GLOBAL CABLE GLAND SOLUTIONS2
Cooper Crouse-Hinds cable glands are the easiest and safest
solution for your installation and maintenance needs. In any
electrical or instrumentation installation, our glands are the
reliable and safe way to move power and signals.
Global manufacturing presence and local inventory provides for
flexibility in meeting our customers installation and project
coordination schedules. The result is best-in-class on-time
delivery, customer satisfaction, and service. Our first-class
technical gland team is available to support product application,
technical specification, and onsite installation training on a
global basis.
Global Cable Gland Solutions
-
5/27/2018 CableGlands[1]
3/12
GLOBAL CABLE GLAND SOLUTIONS 3
International Metallic Cable Gland Solutions
Complete termination solutions for global cable applications
Increased safety, flameproof, and explosionproof terminations for
harsh and hazardous environments Global certifications
Standard in nickel-plated brass with options for stainless steel,
aluminum, and bronze
Full line of accessories, including adapters, unions, and reducers
Time-tested,quality cableglands
from CooperCrouse-Hinds offer:
Complete termination solution for
global cable applications
Ease of cable termination providing
labor and time management
productivity
Explosion-protected connections
contributing to safe operation in
harsh and hazardous environments
Delivery meeting installation and
project coordination schedules
-
5/27/2018 CableGlands[1]
4/12
CABLEGLAND ILLUSTRATION CABLETYPE GLANDTYPE STANDARDMATERIAL CERTIFICATION PROTECTIONTYPEADE 1F
(page 5)
Non-armoured
and armoured
(does not
terminate the
armour)
Non-
armoured
Nickel-
plated
brass
Flameproof &
Increased Safety
ADE 4Fpage 6)
SWA, SWB, STA,
braided marine
shipboard and
lead sheathed
(with addition of
earthing washer)
Armoured Nickel-
plated
brass
Flameproof &
Increased Safety
ADE 6Fpage 7)
SWA, SWB, STA
and braided
marine shipboard
Armoured Nickel-
plated
brass
Flameproof &
Increased Safety
ADE 1FCpage 8)
Non-armoured
and armoured
(does not
terminate the
armour)
Non-
armoured
Barrier
Nickel-
plated
brass
Flameproof,
Increased Safety,
& Explosionproof
ADE 6FCpage 9)
SWA, SWB, STA
and braided
marine shipboard
Armoured
Barrier
Nickel-
plated
brass
Flameproof,
Increased Safety,
& Explosionproof
4
Quick Selection Guide
International Standards
QUICK SELECTION GUIDE
International metallic cable glands also feature Lloyds, DNV, and ABS certifications.
-
5/27/2018 CableGlands[1]
5/12
5
ADE 1F
ORDERING EXAMPLE:
CAP81640 4 KX
OptionsGland Type
9 Stainless steel (316L)
8 Bronze
7 Aluminum
5 Silicone sealing ring with temperature range of
-70C to 220C
K1 Includes locknut and fiber washer
K2 Includes locknut, fiber washer, earth tag, and
shroud
Features
Standard material is nickel-plated brass for superior corrosionresistance
Provides a flameproof and weatherproof seal on the outer sheath of thecable
Standard neoprene seal suitable for use in operating temperatures ATEX(-60C to 100C), IECEx and cULus (-40C to 100C)
Available with optional silicone seal for extreme temperatures Available with metric or NPT threads
See page 10 for related accessories
Gland TypeNon-armoured
Cable TypeNon-armoured and armoured(does not terminate the armour)
Certifications and Compliances LCIE 97ATEX 6008X II 2 GD Exd IIC/Exe II/Ex tD
IECEx LCI 05.0004X Exd IIC/Exe II/Ex tD
cULus Listed for Class I, Zone 2 AEx e II/Ex e II cULus Marine Listed for Class I, Zone 1 AEx e II
/Ex e II
NEMA 4X and IP68
CEPEL-EX-558/05X
GOST-R POCC FR.B03126
NEPSI N GYJ071336U & GYJ071337U
DNV N E-10892
ABS approbation:
n 10-HS 577243-PDA / P1836754-X
Lloyds
OPTIONS (replace lastdigitwith option number):
F B
AG E
SELECTION TABLE
Gland
Size
Entry Thread Size A ThreadLength B
Metric (NPT)
Cable Acceptance GlandLength F
(lessentry)
Hexagon DimensionsMetric
Size
Metric
Catalog No.
NPT
Size
NPT
Catalog No.
Outer Sheath E Across
Flats
Across
Corners GMin. Max.
4 M12 CAP816404 14" CAP818404 15 (12.0) 4.0 8.0 20.0 16.5
4 M16 CAP816594 38" CAP818594 15 (12.0) 4.0 8.5 20.0 20.9
5 M16 CAP816504 38" CAP818504 15 (12.0) 6.0 12.0 22.0 20.9
4 M20 CAP816674 12" CAP818674 15 (20.2) 4.0 8.5 20.0 26.4
5 M20 CAP816694 12" CAP818694 15 (20.2) 6.0 12.0 22.0 26.4
6 M20 CAP816604 12" CAP818604 15 (20.2) 8.5 16.0 25.0 26.4
5 M25 CAP816774 34" CAP818774 15 (20.2) 6.0 12.0 22.0 33.0
6 M25 CAP816794 34" CAP818794 15 (20.2) 8.5 16.0 25.0 33.0
7 M25 CAP816704 34" CAP818704 15 (20.2) 12.0 21.0 27.0 33.0
7 M32 CAP816894 1" CAP818894 15 (25.3) 12.0 21.0 27.0 39.6
8 M32 CAP816804 1" CAP818804 15 (25.3) 16.0 27.5 34.0 45.1
8 M40 CAP816994 1-14" CAP818994 15 (26.0) 16.0 27.5 34.0 48.4
9 M40 CAP816904 1-1
4" CAP818904 15 (26.0) 21.0 34.0 36.0 52.89 M50 CAP817094 1-12" CAP819094 15 (26.5) 21.0 34.0 36.0 60.5
10 M50 CAP817004 1-12" CAP819004 15 (26.5) 27.0 41.0 39.0 60.5
11 M63 CAP817294 2" CAP819294 17 (27.2) 33.0 48.0 41.0 73.7
12 M63 CAP817204 2" CAP819204 17 (27.2) 40.0 56.0 43.0 79.2
12 M75 CAP817394 2-12" CAP819494 18 (40.5) 40.0 56.0 43.0 88.0
13 M75 CAP817304 2-12" CAP819404 18 (40.5) 47.0 65.0 49.0 93.5
14 M90 CAP817594 3" CAP819594 22 (42.0) 54.0 74.0 56.0 104.5
15 M90 CAP817504 3" CAP819504 22 (42.0) 63.0 78.0 61.0 121.0
16 M110 CAP817794 3-12" CAP819604 22 (43.2) 72.0 92.0 62.0 132.0
All dimensions in millimeters unless otherwise noted.
INTERNATIONAL STANDARDS -- FLAMEPROOF & INCREASED SAFETY
-
5/27/2018 CableGlands[1]
6/12
6
ADE 4F
INTERNATIONAL STANDARDS -- FLAMEPROOF & INCREASED SAFETY
Features
Standard material is nickel-plated brass for superior corrosion resistance
Armour clamping and bonding with no reversible components for easyinstallation, minimizing error
Provides flameproof seal on inner jacket and weatherproof seal onouter sheath of cable
Optional earthing washer for use with lead sheathed cable
Standard neoprene seal suitable for use in operating temperatures ATEX(-60C to 100C), IECEx and cULus (-40C to 100C)
Available with optional silicone seal for extreme temperatures
Available with metric or NPT threads
See page 10 for related accessories
Gland TypeArmoured
Cable TypeSteel wire armoured,steel wire braided, steel tapearmoured, braided marine shipboard and leadsheathed (with addition of earthing washer)
Certifications and Compliances LCIE 97 ATEX 6008X II 2 GD Exd IIC/Exe II/Ex
tD
IECEx LCI 05.0004X Exd IIC/Exe II/Ex tD
cULus Listed for Class I, Zone 2 AEx e II/Ex e II
cULus Marine Listed for Class I, Zone 1 AEx e II/
Ex e II
NEMA 4X and IP68
CEPEL-EX-558/05X
GOST-R POCC FR.B03126
NEPSI N GYJ071336U & GYJ071337U
DNV N E-10892
ABS approbation:
n 10-HS 577243-PDA / P1836754-X
Lloyds
F B
A DG E
ORDERING EXAMPLE:
CAP84640 4 KX
OptionsGland Type
9 Stainless steel (316L)
8 Bronze
7 Aluminum
5 Silicone sealing ring with temperature range of
-70C to 220C
K1 Includes locknut and fiber washer
K2 Includes locknut, fiber washer, earth tag, and
shroud
OPTIONS (replace lastdigitwith optionnumber):
All dimensions in millimeters unless otherwise noted.*CAP849604 outer sheath min: 85 max: 107
SELECTION TABLE
Gland
Size
Entry Thread Size A
Thread
Length B
Metric (NPT)
Cable Acceptance
Armour
(max.)
Gland
Length F
(lessentry)
Hexagon Dimensions
Metric
Size
Metric
Catalog No.
NPT
Size
NPT
Catalog No.
Inner Sheath D Outer Sheath EAcross
Flats
Across
Corners GMin. Max. Min. Max.
5 M12 CAP846404 14" CAP848404 15 (12.0) 4.0 8.0 6.0 12.0 0.9 36.0 20.9
5 M16 CAP846594 38" CAP848594 15 (12.0) 4.0 8.5 6.0 12.0 0.9 36.0 20.9
6 M16 CAP846504 38" CAP848504 15 (12.0) 6.0 12.0 8.5 16.0 1.25 42.0 26.4
5 M20 CAP846674 12" CAP848674 15 (20.2) 4.0 8.5 6.0 12.0 0.9 36.0 26.4
6 M20 CAP846694 12" CAP848694 15 (20.2) 6.0 12.0 8.5 16.0 1.25 42.0 26.4
7 M20 CAP846604 12" CAP848604 15 (20.2) 8.5 16.0 12.0 21.0 1.25 46.0 33.0
6 M25 CAP846774 34" CAP848774 15 (20.2) 6.0 12.0 8.5 16.0 1.25 42.0 33.0
7 M25 CAP846794 34" CAP848794 15 (20.2) 8.5 16.0 12.0 21.0 1.25 46.0 33.0
8 M25 CAP846704 34" CAP848704 15 (20.2) 12.0 20.5 16.0 27.5 1.6 56.0 45.1
8 M32 CAP846894 1" CAP848894 15 (25.3) 12.0 21.0 16.0 27.5 1.6 56.0 45.1
9 M32 CAP846804 1" CAP848804 15 (25.3) 16.0 27.5 21.0 34.0 1.6 63.0 52.8
9 M40 CAP846994 1-14" CAP848994 15 (26.0) 16.0 27.5 21.0 34.0 1.6 63.0 52.8
10 M40 CAP846904 1-14" CAP848904 15 (26.0) 21.0 34.0 27.0 41.0 2.0 68.0 60.5
10 M50 CAP847094 1-12" CAP849094 16 (26.5) 21.0 34.0 27.0 41.0 2.0 68.0 60.5
11 M50 CAP847004 1-12" CAP849004 16 (26.5) 27.0 41.0 33.0 48.0 2.5 74.0 70.4
12 M63 CAP847294 2" CAP849294 17 (27.2) 27.0 41.0 33.0 48.0 2.5 77.0 79.2
13 M63 CAP847204 2" CAP849204 17 (27.2) 33.0 48.0 40.0 56.0 2.5 85.0 93.5
13 M75 CAP847394 2-12" CAP849494 18 (40.5) 40.0 56.0 47.0 65.0 2.5 85.0 93.5
14 M75 CAP847304 2-12" CAP849404 18 (40.5) 47.0 65.0 54.0 74.0 2.5 92.0 104.5
15 M90 CAP847594 3" CAP849594 22 (42.0) 54.0 74.0 63.0 83.0 3.15 104.0 121.0
16 M90 CAP847504 3" CAP849504 22 (42.0) 63.0 82.0 72.0 93.0 3.15 108.0 132.0
16 M90 CAP847574 3-12" CAP849604 N/A (43.2) 63.0 82.0 72.0* 93.0* 3.15 108.0 132.0
17 M110 CAP847794 4" CAP849704 22 (44.5) 72.0 92.0 85.0 107.0 3.15 115.0 148.5
-
5/27/2018 CableGlands[1]
7/12
7INTERNATIONAL STANDARDS -- FLAMEPROOF & INCREASED SAFETY
ADE 6F
Features
Standard material is nickel-plated brass for superior corrosionresistance
Armour clamping and bonding with no reversible components for easyinstallation, minimizing error
Provides fully inspectable inner seal after installation
Flameproof diaphragm seal on inner jacket does not damage cablesexhibiting cold-flow; weatherproof seal on outer sheath of cable
Deluge boot provides enhanced protection from water ingress
Standard neoprene seal suitable for use in operating temperatures ATEX(-60C to 100C), IECEx and cULus (-40C to 100C)
Available with metric or NPT threads
See page 10 for related accessories
Gland TypeArmoured with elastomeric diaphragm
Cable TypeSteel wire armoured, steel wire braided, steeltape armoured and braided marine shipboard
Certifications and Compliances LCIE 97 ATEX 6008X II 2 GD Exd IIC/Exe II/
Ex tD
IECEx LCI 05.0004X Exd IIC/Exe II/Ex tD
cULus Listed for Class I, Zone 2 AEx e II/Ex e II
cULus Marine Listed for Class I, Zone 1
AEx e II/Ex e II
NEMA 4X and IP68
CEPEL-EX-558/05X GOST-R POCC FR.B03126
NEPSI N GYJ071336U & GYJ071337U
DNV N E-10892
ABS approbation:
n 10-HS 577243-PDA / P1836754-X
Lloyds
F B
ADG E
ORDERING EXAMPLE:
CAP96559 4 KX
OptionsGland Type
9 Stainless steel (316L)
8 Bronze
7 Aluminum
K1 Includes locknut and fiber washer
K2 Includes locknut, fiber washer, earth tag, and
shroud
OPTIONS (replace lastdigitwith option number):
SELECTION TABLE
Gland
Size
Entry Thread Size A
Thread
Length B
Metric (NPT)
Cable Acceptance
Armour
(max.)
Gland
Length F
(lessentry)
Hexagon Dimensions
Metric
Size
Metric
Catalog No.
NPT
Size
NPT
Catalog No.
Inner Sheath D Outer Sheath EAcross
Flats
Across
Corners GMin. Max. Min. Max.
5 M16 CAP965594 38" CAP967594 15 (12.0) 3.0 7.5 6.0 12.0 0.9 46.0 20.9
5 M20 CAP965674 12" CAP967674 15 (20.2) 3.0 7.5 6.0 12.0 0.9 46.0 26.4
6 M20 CAP965694 12" CAP967694 15 (20.2) 6.5 11.0 8.5 16.0 1.25 53.0 26.4
7 M20 CAP965604 12" CAP967604 15 (20.2) 9.0 14.5 12.0 21.0 1.25 59.0 33.0
7 M25 CAP965794 34" CAP967794 15 (20.2) 9.0 14.5 12.0 21.0 1.25 59.0 33.0
8 M25 CAP965704 34" CAP967704 15 (20.2) 12.0 19.5 16.0 27.5 1.6 74.5 45.1
8 M32 CAP965894 1" CAP967894 15 (25.3) 12.0 19.5 16.0 27.5 1.6 74.5 45.1
9 M32 CAP965804 1" CAP967804 15 (25.3) 17.5 26.0 21.0 34.0 1.6 83.5 52.8
9 M40 CAP965994 1-14" CAP967994 15 (26.0) 17.5 26.0 21.0 34.0 1.6 83.5 52.8
10 M40 CAP965904 1-14" CAP967904 15 (26.0) 23.0 33.0 27.0 41.0 2.0 92.0 60.5
10 M50 CAP966094 1-12" CAP968094 16 (26.5) 23.0 33.0 27.0 41.0 2.0 92.0 60.5
11 M50 CAP966004 2" CAP968294 16 (27.2) 28.5 41.0 33.0 48.0 2.5 104.0 70.4
For larger sizes, use ADE 4F design. Please refer to previous page.
All dimensions in millimeters unless otherwise noted.
-
5/27/2018 CableGlands[1]
8/12
8 INTERNATIONAL STANDARDS -- FLAMEPROOF & INCREASED SAFETY
ADE 1FC
Features
Standard material is nickel-plated brass for superior corrosionresistance
Provides a flameproof and weatherproof seal on the outer sheath of thecable
Provides explosionproof compound seal (denoted by red back nut) onconductors
Deluge boot provides enhanced protection from water ingress
Standard neoprene seal suitable for use in operating temperatures-60C (-25C UL) to 80C
Available with metric or NPT threads
See page 10 for related accessories
Gland TypeNon-armoured barrier
Cable TypeNon-armoured, armoured and tray cable(does not terminate the armour)
Certifications and Compliances LCIE 97ATEX 6008X II GD Exd IIC/Exe II/Ex tD
IECEx LCI 05.0004X Ex c e IIC/Ex c e II/Ex tD cULus Listed for Class I, Zone 2 AEx de II/Ex de II
UL Marine Listed for Class I, Division 2, Groups
A, B, C, D
NEMA 4X and IP68
CEPEL EX-558/05X
GOST-R POCC FR.B03126
NEPSI N GYJ071336U & GYJ071337U
DNV N E-10892
ABS approbation:
n 10-HS 577243-PDA / P1836754-X
Lloyds
F B
A GE
All dimensions in millimeters unless otherwise noted.*Aluminum not currently available with UL marine certification.
**Contact Customer Service or your sales representative for amended UL marine range.
SELECTION TABLE
Gland
Size
Entry Thread Size AThread
Length B
Metric (NPT)
Cable AcceptanceMax
No.
Cores
Gland
Length F
(less entry)
Hexagon Dimensions
Metric
Size
Metric
Catalog No.
NPT
Size
NPT
Catalog No.
Outer SheathE Across
Flats
Across
Corners GMin. Max.
4 M16 CAP019594 38" CAP011594 15 (12.0) 4.0 7.5 6.0 46.0 - 20.9
4 M20 CAP019674 12" CAP011674 15 (22.2) 4.0 7.5 6.0 46.0 - 26.4
5 M20 CAP019694 12" CAP011694 15 (22.2) 6.5 11.0 6.0 53.0 - 26.4
6 M20 CAP019604 12" CAP011604 15 (22.2) 9.0 14.5 10.0 59.0 - 33.0
6 M25 CAP019794 34" CAP011794 15 (22.5) 9.0 14.5 10.0 59.0 - 33.0
7 M25 CAP019704 34" CAP011704 15 (22.5) 12.0 19.5 21.0 74.5 - 45.1
7 M32 CAP019894 1" CAP011894 15 (27.3) 12.0 19.5 21.0 74.5 - 45.1
8 M32 CAP019804 1" CAP011804 15 (27.3) 17.5 26.0 42.0 83.5 - 52.8
8 M40 CAP019994 1-14" CAP011994 15 (28.0) 17.5 26.0 42.0 83.5 - 52.8
9 M40 CAP019904 1-14" CAP011904 15 (28.0) 23.0 33.0 60.0 92.0 - 60.5
9 M50 CAP019094 1-12" CAP011094 16 (28.5) 23.0 33.0 60.0 92.0 - 60.5
10 M50 CAP019004 2" CAP011004 16 (29.2) 28.5 41.0 80.0 104.0 - 70.4
10 M63 CAP019204 - - 16 28.5 41.0 80.0 - - 73.7
11 M63 CAP019294 2" CAP011294 17 (29.2) 43.0 48.0 100.0 98.0 - 70.4
12 M63 CAP019274 2" CAP011204 17 (29.2) 50.0 56.0 100.0 103.0 - 79.2
12 - - 2-12" CAP011494 42.5 50.0 56.0 100.0 103.0 - 79.2
13 M75 CAP019304 2-12" CAP011404 18 (42.5) 59.0 65.0 120.0 111.0 - 93.5
13 - - 3" CAP012504 44 59.0 65.0 120.0 111.0 - 93.5
14 M90 CAP010594 3" CAP012574 22 (44.0) 66.0 73.0 140.0 120.0 - 104.5
14 - - 3-12" CAP012604 45.2 66.0 73.0 140.0 120.0 - 104.5
15 M90 CAP010504 3" CAP012594 22 (44.0) 75.0 82.0 140.0 125.0 - 121.0
15 - - 3-12" CAP012694 45.2 75.0 82.0** 140.0 125.0 - 121.0
16 M110 CAP010794 4" CAP012704 22 (46.5) 85.0 92.0** 200.0 128.0 - 132.0
ORDERING EXAMPLE:
CAP01959 4 KX
OptionsGland Type
9 Stainless steel (316L)
8 Bronze
7 Aluminum*
K1 Includes locknut and fiber washer
K2 Includes locknut, fiber washer, earth tag, and
shroud
OPTIONS (replace lastdigitwith optionnumber):
-
5/27/2018 CableGlands[1]
9/12
9INTERNATIONAL STANDARDS -- FLAMEPROOF & INCREASED SAFETY
ADE 6FC
SELECTION TABLE
Gland
Size
Entry Thread Size A
Thread
Length B
Metric
(NPT)
Cable Acceptance
Armour
(Max.)
Gland
Length
F
(less entry)
Hexagon Dimensions
Metric
Size
Metric
Catalog No.
NPT
Size
NPT
Catalog No.
Inner Sheath and Cores Outer Sheath E
Across
Flats
Across
Corners G
Max Over
Cores
C
Max Inner
Sheath
D
Max No.
of Cores Min. Max.
5 M16 CAP969594 38" CAP974594 15 (12.0) 6.5 7.5 6.0 6.0 12.0 0.9 46.0 - 20.9
5 M20 CAP969674 12" CAP971674 15 (20.2) 6.5 7.5 6.0 6.0 12.0 0.9 46.0 - 26.4
6 M20 CAP969694 12" CAP971694 15 (20.2) 9.5 11.0 6.0 8.5 16.0 1.25 53.0 - 26.4
7 M20 CAP969604 12" CAP971604 15 (20.2) 12.0 14.5 10.0 12.0 21.0 1.25 59.0 - 33.0
7 M25 CAP969794 34" CAP971794 15 (20.5) 12.0 14.5 10.0 12.0 21.0 1.25 59.0 - 33.0
8 M25 CAP969704 34" CAP971704 15 (20.5) 17.0 19.5 21.0 16.0 27.5 1.6 74.5 - 45.1
8 M32 CAP969894 1" CAP971894 15 (25.3) 17.0 19.5 21.0 16.0 27.5 1.6 74.5 - 45.1
9 M32 CAP969804 1" CAP971804 15 (25.3) 23.0 28.0 42.0 21.0 34.0 1.6 83.5 - 52.8
9 M40 CAP969994 1-14" CAP971994 15 (26.0) 23.0 28.0 42.0 21.0 34.0 1.6 83.5 - 52.8
10 M40 CAP969904 1-14" CAP971904 15 (26.0) 29.0 33.0 60.0 27.0 41.0 2.0 92.0 - 60.5
10 M50 CAP970094 1-12" CAP972094 15 (26.5) 29.0 33.0 60.0 27.0 41.0 2.0 92.0 - 60.511 M50 CAP970004 2" CAP972004 16 (27.2) 36.5 41.0 80.0 33.0 48.0 2.5 104.0 - 70.4
12 M63 CAP970294 2" CAP972274 17 (29.2) 43.0 48.0 100.0 40.0 56.0 2.5 108.0 - 79.2
13 M63 CAP970204 2" CAP972204 17 (29.2) 50.0 56.0 100.0 46.0 65.0 2.5 118.0 - 93.5
13 M75 CAP970394 2-12" CAP972494 18 (42.5) 50.0 56.0 100.0 46.0 65.0 2.5 118.0 - 93.5
14 M75 CAP970304 2-12" CAP972404 18 (42.5) 59.0 65.0 120.0 54.0 74.0 2.5 124.0 - 104.5
14 - - 3" CAP972574 (44) 59.0 65.0 120.0 54.0 74.0 2.5 124.0 - 104.5
15 M90 CAP970594 3" CAP972594 22 (44.0) 66.0 73.0 140.0 63.0 83.0 3.15 133.0 - 121.0
15 - - 3-12" CAP972694 (45.2) 66.0 73.0 140.0 63.0 83.0 3.15 133.0 - 121.0
16 M90 CAP970504 3" CAP972504 22 (44.0) 75.0 82.0 140.0 72.0 93.0 3.15 137.0 - 132.0
16 - - 3-12" CAP972604 (45.2) 75.0 82.0** 140.0 72.0 93.0 3.15 137.0 - 132.0
17 M110 CAP970794 4" CAP972704 22 (46.5) 85.0 92.0** 200.0 85.0 107.0 3.15 142.0 - 148.5
Features
Standard material is nickel-plated brass for superior corrosionresistance
Armour clamping with no reversible components for easy installation,minimizing error
Provides explosionproof compound seal (denoted by red back nut) onconductors and weatherproof seal on outer sheath of cable
Deluge boot provides enhanced protection from water ingress Standard neoprene seal suitable for use in operating temperatures
-60C (-25C UL) to 80C
Available with metric or NPT threads
See page 10 for related accessories
Gland TypeArmoured barrier
Cable TypeSteel wire armoured,steel wire braided, steel tapearmoured, braided marine shipboard and leadsheathed (with addition of earthing washer)
Certifications and Compliances ATEX LCIE 97ATEX 6008X Exd IIC/Exe II/Ex tD/
Ex II 2 GD
IECEx LCI 05.0004X
cULus Listed for Class I, Zone 2 AEx de II/Ex de II
cULus Marine Listed for Class I, Division 1,Groups A, B, C, D
NEMA 4X and IP68
CEPEL-EX-558/05X
GOST-R POCC FR Bo2011
NEPSI N GYJ071336U & GYJ071337U
ABS approbation:
n 10-HS 577243-PDA / P1836754-X
DNV N E-10892
Lloyds
F B
ADCG E
ORDERING EXAMPLE:
CAP96959 4 KX
OptionsGlandType
9 Stainless steel (316L)
8 Bronze
7 Aluminum*
K1 Includes locknut and fiber washer
K2 Includes locknut, fiber washer, earth tag, and
shroud
OPTIONS (replace lastdigitwith option number):
All dimensions in millimeters unless otherwise noted.
*Aluminum not currently available with UL marine certification.**Contact Customer Service or your field sales representative for amended UL marine range.
-
5/27/2018 CableGlands[1]
10/12
ACCESSORIES10
Accessories
Cooper Crouse-Hinds offers the most extensive offering of accessories to meet
the needs of any installation
Accessories include: Adapters Reducers Unions Stopping Plugs Breathers / Drains Locknuts Washers Earth Tags Shrouds
-
5/27/2018 CableGlands[1]
11/12
11REFERENCE GUIDE
Reference Guide
General Terms
Ambient Temperature All encompassing temperature within a given area
Armour Mechanical protection usually accomplished by a metallic
layer of tape, braid or served wires; normally found underthe outer sheath of a cable
Armoured Cable A cable provided with a wrapping of metal, usually steelwires, flat tapes, or interlocked tapes, primarily for thepurpose of mechanical protection
ATEX French term Atmosphres Explosibles (EU directive94/9/EC)
AWG American Wire Gauge
Braid Armour A fibrous or metallic group of filaments interwoven incylindrical form covering one or more conductors
Cable Gland A device used for the entry of cables or cords into electricalequipment providing armour clamping, sealing and/or strainrelief
CB Certification Body
Cold Flow Any permanent deformation of the inner sheath of a cabledue to pressure or mechanical force, without the aid of heatsoftening
CWCMC Continuously Welded Corrugated Metal-clad Cable
DTS01 Deluge Test developed by Shell, mainly used on offshorerigs
Directive A legislative act of the European Union
EHSR Essential Health and Safety Requirements Requirementsfrom new approach Directives, e.g. LVD, ATEX
Hazardous Location where fireor explosion hazards mayexist dueLocation to the presenceof flammable gases, dusts, or fibers
IECEx CB IECEx Certifying Body
IECEx TR IECEx Test Report
IP Ingress Protection
ITC Instrument tray cable
ITC-HL Instrument Tray Cable Hazardous Location
LVD Low Voltage Directive (EU directive 2006/95/EC)
MC Metal-clad Cable
MC-HL Metal-clad Cable-Hazardous Location, for Class I, Division
1 locationsMI Mineral Insulated
MV Medium Voltage
NB Notified Body
PLTC Power Limited Tray Cable
Primary Seal A seal that isolates process fluids from an electricalsystem and has one side of the seal in contact with theprocess fluid
QAR Quality Assurance Report quality portion of IECExcertification
QAN Quality Assurance Notice quality portion of ATEXcertification
Secondary Seal A seal that is designed to prevent the passage of processfluids at the pressure it will be subjected to upon failure ofthe primary seal (secondary seals are required for sealingconduits and cables in Class I explosive gas atmospheres,where failure of a primary seal could allow flammableprocess fluids to leak into electrical equipment, withdisastrous results)
SWA SteelWireArmour
STA Steel Tape Armour (also DSTA fordoublesteelwire armour)
SWB Steel Wire Braid
TC Tray Cable
TC-ER Tray Cable Exposed Run
TECK A type of metal-clad interlocked armour cable (mainlyused in Canada)
Wet Locations Installations underground or in concrete slabs or masonryin direct contact with the earth; locations subject tosaturation with water or other liquids, such as wash downareas; and in unprotected locations exposed to weather
AWG to mm2 Conversion Table
AWG Diameter mm) Area mm2) Diameter in)30 0.252 0.05 0.010
28 0.319 0.08 0.013
26 0.422 0.14 0.017
24 0.564 0.25 0.022
22 0.658 0.34 0.026
20 0.798 0.50 0.031
18 0.977 0.75 0.038
16 1.382 1.50 0.054
14 1.784 2.50 0.070
12 2.257 4.0 0.089
10 2.764 6.0 0.109
8 3.568 10.0 0.140
6 4.514 16.0 0.178
AWG Diameter mm) Area mm2) Diameter in)4 5.642 25 0.222
2 6.676 35 0.263
1 7.979 50 0.314
1/0 8.368 55 0.329
2/0 9.441 70 0.372
3/0 10.998 95 0.433
4/0 12.361 120 0.487
300MCM 13.820 150 0.544
350MCM 15.348 185 0.604
500MCM 17.481 240 0.688
600MCM 19.544 300 0.769
750MCM 22.568 400 0.888
1000MCM 25.231 500 0.993
-
5/27/2018 CableGlands[1]
12/12
Printed in USA5031-0212
U.S. (Global Headquarters):
Cooper Crouse-Hinds
Wolf & Seventh North Streets
Syracuse, NY 13221
(866) 764-5454
FAX: (315) 477-5179
FAX Orders Only: (866) 653-0640
Canada:
Cooper Crouse-Hinds Canada
Toll Free: 800-265-0502
FAX: (800) 263-9504
FAX Orders only: (866) 653-0645
Mexico/Latin America/Caribbean:
Cooper Crouse-Hinds, S.A. de C.V.
52-555-804-4000
FAX: 52-555-804-4020
Middle East (Dubai):
Cooper Crouse-Hinds LLC
971 4 4272500
FAX: 971 4 4298521
Korea:
Cooper Crouse-Hinds Korea
82 2 538 342582 2 538 3505
Europe (Germany):
Cooper Crouse-Hinds GmbH
49 (0) 6271 806-500
49 (0) 6271 806-476
China:
Cooper Crouse-Hinds Pte. Ltd.
86-21-2899-3600FAX: 86-21-2899-4055
India:
Cooper India Pvt. Ltd.
91-124-4683888
FAX: 91-124-4683899
Australia:
Cooper Electrical Australia
61-2-8787-2777FAX: 61-2-9609-2342
Singapore:
Cooper Crouse-Hinds Pte. Ltd.
65-6297-4849
FAX: 65-6297-4819
For more information:If further assistance is required, please contact an authorized Cooper Crouse-Hinds Distributor,
Sales Office, or Customer Service Department.
Your Authorized Cooper Crouse-Hinds Distributor is:
Cooper Industries, Ltd.
600 Travis, Ste. 5800
Houston, TX 77002-1001
P: 713-209-8400
www.cooperindustries.com
www.crouse-hinds.comCooper Crouse-Hinds is a registered trademark of Cooper Industries, Inc.
2012 Cooper Industries, Inc.