![Page 1: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/1.jpg)
No. 1/336 Chhattisgarh State Industrial Development Corporation Limited (A Government of Chhattisgarh Undertaking) First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.) EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt) CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004 Website: www.csidc.in, Email : [email protected], [email protected]
No./CSIDC/MKD/ PS-VII /15-16/ Raipur, Dated :
SCHEDULE “C” LIST OF PARALLEL RATE CONTRACT FOR ITEM- RCC HUME PIPE
S.No. Name of the RC Holding Firm Valid Dated Rate Contract No.
1 2 3 4 01 M/s Aditya Industries,
C/o Dhansiram Bhajankumar, Rupdev Market, Deviganj Road, Ambikapur Distt.- Surguja (C.G.) 497001 Mo.- 9425256300 Email- bhajan [email protected]
31-03-2015 To
01-04-2016
Rate Contract No. CSIDC/MKD/PS-VII /102/510/14-15/RCCHP/AI/6467
02 M/s Surguja Cement Pipe Industries, Manendragarh Road, Ambikapur Distt.- Surguja (C.G.) 497001 Mo.- 9425256300, 9826956300 Email- bhajan [email protected]
31-03-2015 To
01-04-2016
Rate Contract No. CSIDC/MKD/PS-VII /102/510/14-15/RCCHP/SCPI/6468
03 M/s Raigarh Hume & Spun Pipe, Near Stadium, Industrial Area Raigarh (C.G.) Mo.- 9300676323, 9301010290 Email- [email protected]
31-03-2015 To
01-04-2016
Rate Contract No. CSIDC/MKD/PS-VII /102/510/14-15/RCCHP/RH&SP/6469
04 M/s Dhanshri & Company, Deviganj Road Ambikapur Surguja (C.G.) 497001 Mo.- 09425580211 Ph.- 07774-235611
31-03-2015 To
01-04-2016
Rate Contract No. CSIDC/MKD/PS-VII /102/510/14-15/RCCHP/D&C/6470
05 M/s Agrasen Concrete Products, Navagarh Road, Bemetara Distt- Durg (C.G.) Mo.- 9977700300
31-03-2015 To
01-04-2016
Rate Contract No. CSIDC/MKD/PS-VII /102/510/14-15/RCCHP/ACP/6471
06 M/s Gopesh Cement Arts, Dayalband Bilaspur (C.G.) Mo.- 9300325947, 9827485186 Email- [email protected]
31-03-2015 To
01-04-2016
Rate Contract No. CSIDC/MKD/PS-VII /102/510/14-15/RCCHP/GCA/6472
07 M/s Radheshyam Benishyam Kesary & Co., Dayalband Bilaspur (C.G.) Mo.- 9827167998, 9300333354 Email- [email protected]
31-03-2015 To
01-04-2016
Rate Contract No. CSIDC/MKD/PS-VII /102/510/14-15/RCCHP/RBK&C/6473
08 M/s Bilaspur Cement Products, C/O Shri Sai Teles & Sanitary Main Road Tarwa Naka Bilaspur (C.G.) 495001 Mo.- 9425219302 9893968974 Ph.-07752-410302
31-03-2015 To
01-04-2016
Rate Contract No. CSIDC/MKD/PS-VII /102/510/14-15/RCCHP/BCP/6474
09 M/s Vasudev Shamji Savaria, Bajirao Mehrapara Raigarh (C.G.) 496001 Ph.- 07762-220050 Mo.- 099267-42045 Email- [email protected]
31-03-2015 To
01-04-2016
Rate Contract No. CSIDC/MKD/PS-VII /102/510/14-15/RCCHP/VSS/6475
10 M/s Dinesh Industries, Telibandha, Near Gali No.- 6, Ravigram, Raipur Factory 730 A Industrial Estate Urla Raipur (C.G.) 492001 Ph.- 0771-3265888 Mo.- 9755042331 , 9926156001
31-03-2015 To
01-04-2016
Rate Contract No. CSIDC/MKD/PS-VII /102/510/14-15/RCCHP/DI/6476
![Page 2: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/2.jpg)
No. 2/336
11 M/s Quality Cement Pipes, Add : 11,12 Industrial Estate Bhanpuri Raipur (C.G.) 493221 Ph.- 0771-4024190, Mo.- 9752005557
31-03-2015 To
01-04-2016
Rate Contract No. CSIDC/MKD/PS-VII /102/510/14-15/RCCHP/QCP/6477
12 M/s Raj Pipe, Infront of Industrial Estate, G.E. Road, Rajnandgaon (C.G.)
31-03-2015 To
01-04-2016
Rate Contract No. CSIDC/MKD/PS-VII /102/510/14-15/RCCHP/RP/6478
13 M/s Akash Pipe Industries, Dharampara Mungeli Bilaspur (C.G.) 495334 Mo.- 9993070099
31-03-2015 To
01-04-2016
Rate Contract No. CSIDC/MKD/PS-VII /102/510/14-15/RCCHP/API/6479
14 M/s Korba Cement Products, Urga-Korba (C.G.) Mo.- 9425224499 Email- [email protected]
31-03-2015 To
01-04-2016
Rate Contract No. CSIDC/MKD/PS-VII /102/510/14-15/RCCHP/KCP/6480
15 M/s Dhansree Concrete Products, Manendragarh Road Ambikapur (C.G.) 497001 Mo.- 9425580211
31-03-2015 To
01-04-2016
Rate Contract No. CSIDC/MKD/PS-VII /102/510/14-15/RCCHP/DCP/6481
16 M/s Shivshakti Industries, Kena Bandh Bouripara, Ambikapur, Distt Surguja (C.G.) 497001 Mo.-9425582023
31-03-2015 To
01-04-2016
Rate Contract No. CSIDC/MKD/PS-VII /102/510/14-15/RCCHP/SI/6482
17 M/s Jai Mahamaya Cement Pipe Industries, Mission Chowk, Ring Road, Ambikapur Distt.- Surguja (C.G.) 497001 Mo.- 9826122358 Email- [email protected]
10-04-2015 To
01-04-2016
Rate Contract No. CSIDC/MKD/PS-VII /102/510/15-16/RCCHP/JMCPI/6483
18 M/s Jai Ambe Cement Product, Vill-Sargawan, Teh.-Ambikapur Distt.- Surguja (C.G.) 497001 Mo.- 9826122358, 9425254259
10-04-2015 To
01-04-2016
Rate Contract No. CSIDC/MKD/PS-VII /102/510/15-16/RCCHP/JACP/6484
19 M/s Jaiswal Cement Products, Mission Chowk, Ring Road, Ambikapur Distt.- Surguja (C.G.) 497001 Mo.- 9826122358 , 9425254259 Email- [email protected]
10-04-2015 To
01-04-2016
Rate Contract No. CSIDC/MKD/PS-VII /102/510/15-16/RCCHP/JCP/6485
20 M/s Bhilai Cement Pipe Manufacturing co., 70-A,Industrial Estate , Nandini Road, Bhilai (C.G.) Ph- 0788-2286518 Mo.- 9893115028, 9981125028
10-04-2015 To
01-04-2016
Rate Contract No. CSIDC/MKD/PS-VII /102/510/15-16/RCCHP/BCPMC/6486
21 M/s Bhawani Cement Pipe Industries, Kh.No-521 D 1, Om Complex, Fafadih Village Deori Bilaspur Road Raipur (C.G.) 492001 Ph.-07714092724, Mo.- 9425507207
10-04-2015 To
01-04-2016
Rate Contract No. CSIDC/MKD/PS-VII /102/510/15-16/RCCHP/BCPI/6487
22 M/s Bastar Cement Products, Geedam Road, P.O Pandripani, Jagdalpur (Bastar) 494001 Mo.- 9826612012, 9425212012 Email- [email protected]
10-04-2015 To
01-04-2016
Rate Contract No. CSIDC/MKD/PS-VII /102/510/15-16/RCCHP/BCP/6488
23 M/s Engineers Enterprises, Rawabhata Industrial Area P.O. Birgaon Raipur (C.G.) 493221 Mo.-9826612012, 9425212012 Email- [email protected]
10-04-2015 To
01-04-2016
Rate Contract No. CSIDC/MKD/PS-VII /102/510/15-16/RCCHP/EE/6489
24 M/s Grewal Cement Pipe Industries, 31 Industrial Area, P.O Birgaon- 493221 Raipur (C.G.) Mo.- 9826612012, 9425212012 Email- [email protected]
10-04-2015 To
01-04-2016
Rate Contract No. CSIDC/MKD/PS-VII /102/510/15-16/RCCHP/GCPI/6490
![Page 3: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/3.jpg)
No. 3/336
(Suresh Keshi) General Manager
25 M/s R.C.C. Hume Pipe & Products, S.U.I.E. Frazerpur Nayamundapara , Industrial Estate, Jagdalpur Bastar (C.G.) Ph.- 07782227204, Mo.-9425260321,9406286611 Email- [email protected]
30-04-2015 To
01-04-2016
Rate Contract No. CSIDC/MKD/PS-VII /102/510/15-16/RCCHP/RCCHP&P/6491
26 M/s Chhattisgarh Pipe Industries, Village - Bhoinabhata Tah. & Distt. Bemetara (C.G.) Mo.- 9993730777
30-04-2015 To
01-04-2016
Rate Contract No. CSIDC/MKD/PS-VII /102/510/15-16/RCCHP/CPI/6492
27 M/s Star Industries, Mukhtiyarpara Nagpur Manendragarh Korea (C.G.) Mo.- 09424260460, 09993251066
30-04-2015 To
01-04-2016
Rate Contract No. CSIDC/MKD/PS-VII /102/510/15-16/RCCHP/SI/6493
![Page 4: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/4.jpg)
No. 4/336 S Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking) First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.) EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt) CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004 Website: www.csidc.in, Email : [email protected], [email protected]
No./CSIDC/MKD/ PS-VII /14-15/ Raipur, Dated :
Registered A/D Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/AI/6467 Dated: 31-03-2015 To,
M/s Aditya Industries, C/o Dhansiram Bhajankumar, Rupdev Market, Deviganj Road, Ambikapur Distt.- Surguja (C.G.) 497001 Mo.- 9425256300 Email- bhajan [email protected]
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 31-03-2015 to 01-04-2016) Ref :- (I) This Office Tender Enquiry No. PS-VII/CSIDC/MKD/102/510/14-15
(II) Bid No. 8409 Dated 08-11-2014 (III) Your Offer acceptance alongwith undertaking submitted on dated 20-03-2015
Dear Sir, You are hereby informed that your above referred tender read with subsequent letters mentioned above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction. You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the time of getting the payment. SCHEDULES ANNEXED: 1. Schedule “A” Description of Stores, Prices, Duties/Taxes . 2. Annexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions of contract (if any). 4. Schedule “C” Information to DDOs about parallel rate contracts. 5. Schedule “D” Format for Drawal Report. Encl. 13 pages
Yours faithfully,
(Suresh Keshi) General Manager
For and on behalf of the purchaser Named in CSIDC Form No.2
![Page 5: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/5.jpg)
No. 5/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/AI/6467 Dated: 31-03-2015 Copy to, 1. The Secretary, Chhattisgarh Vidhan Sabha ,Raipur .
2. The Registrar, Honourable High court Chhattisgarh, Bilaspur .
3. The Accountant General Chhattisgarh State, Raipur.
4. All HODs of Chhattisgarh Govt. with a request to circulate the copy of R/C to all Direct Demanding Officers of your institution against issue of purchase order (Indent) in Favour of Rate Contract Holders of CSIDC.
5. All Collectors, Chhattisgarh State against issue of purchase order (Indent) in Favour of Rate Contract holders of CSIDC.
6. The Director Treasury, Chhattisgarh Govt., Raipur with a request to circulate copy of R/C to all branches under your control .
7. (i) Director of Public Instruction Department Pension Bada Raipur (ii) Engineer in Chief PHED C.G. Neer Bhawan, Raipur (iii) The Commissioner , Local Administrator , RDA Building Raipur (iv) Engineer in Chief PWD C.G.Civil lines Raipur .
Sr. No. 1 to 7 above are requested to call for original INK-SIGNED Rate Contract for verification to their full satisfaction including validity of various documents like Registration, Tax Registration etc. before taking action i.e. against issue of purchase order in Favour of Rate Contract holders of CSIDC, pre dispatched inspection of stores, acceptance of store.
8. (i) Dy.Director (Q.A.) , DGS&D, Bhilai, Durg (C.G.). (ii) Manager (Operation) Indian Register of Shipping, Senior MIG-2, Secter A, 1st Floor,
Infront of Bank of India Indrapuri Bhopal. (iii) Chief Engineer, PDIL, 4th floor, 4/2 Karaya Road, 67 Shekespeare Sarani, Kolkata (W.B.) (iv) General Manager (Inspection) RITES Ltd., Church gate Station Road, Second Floor, M.K.
Road, Mumbai-400020 (v) Operations Manager SGS India Pvt, Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal (MP)-
462011. above (i) to (v) are requested to call for original INK-SIGNED Rate Contract For Verification to their full satisfaction including validity of various documents like Validity of Registration, BIS Registration etc. before taking action i.e. inspection of stores, as the responsibility rests with the concerned authority. For information and necessary action against Authorized Inspection Agency accorded by CSIDC for inspection of stores.
9. Incharge, Monitoring Cell, MKT-1 CSIDC, Ltd. Raipur for necessary action against inspection of stores . 10. Manager (Tender), Marketing Div., CSIDC Ltd., Raipur. He is requested to maintain a master file
of Rate Contract. 11. Computer cell, CSIDC Ltd., Raipur to release Rate Contract on CSIDC website.
12. Main file of Item- RCC HUME PIPE
(Suresh Keshi) General Manager
![Page 6: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/6.jpg)
No. 6/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/AI/6467 Dated: 31-03-2015
SCHEDULE “A” Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per Annexure’A’ enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Aditya Industries, THE FIRM C/o Dhansiram Bhajankumar, Rupdev Market,
Deviganj Road, Ambikapur Distt.- Surguja (C.G.) 497001 Mo.- 9425256300 Email- bhajan [email protected]
(b) NAME AND FULL ADDRESS OF :- M/s Aditya Industries, MANUFACTURER C/o Dhansiram Bhajankumar, Rupdev Market,
Deviganj Road, Ambikapur Distt.- Surguja (C.G.) 497001 Mo.- 9425256300 Email- bhajan [email protected]
(C) Category :- General 2. VALIDITY OF RATE CONTRACT :- From 31-03-2015 To 01-04-2016 3. DESCRIPTION OF ITEM- RCC HUME PIPE SPECIFICATION, UNIT RATE AS BELOW
S.No. Item Code No. Item Description Class Rate ( )
E.D. VAT/CST Extra As Applicable
Rate Per Meter
Schedule -1: Reinforced Concrete, Light duty, Non-Pressure Pipes, Class: NP2, with ends of the Pipes suitable for collar joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
1 RCCHPF80001003 150 208.95 2 RCCHPF80001008 350 350.52 3 RCCHPF80001010 450 449.06
4 RCCHPF80001012 600 760.91 Schedule -3: Reinforced Concrete, Medium duty, Non-Pressure Pipes, Class: NP3, with ends of the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
5 RCCHPF80001045 150 183.37 6 RCCHPF80001049 300 309.35 7 RCCHPF80001050 350 415.80 8 RCCHPF80001051 400 462.00 9 RCCHPF80001052 450 1050.00
10 RCCHPF80001053 500 1155.00 11 RCCHPF80001054 600 1480.50 12 RCCHPF80001055 700 1680.00 13 RCCHPF80001056 800 2250.00 14 RCCHPF80001057 900 2936.38 15 RCCHPF80001058 1000 3052.39 16 RCCHPF80001059 1100 3465.00 17 RCCHPF80001060 1200 4378.50
(Suresh Keshi)
General Manager
![Page 7: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/7.jpg)
No. 7/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/AI/6467 Dated: 31-03-2015
Schedule -5: Reinforced Concrete, Heavy duty, Non-Pressure Pipes, Class: NP4, with ends of the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
18 RCCHPF80001087 150 202.08 19 RCCHPF80001091 300 415.80 20 RCCHPF80001092 350 462.00 21 RCCHPF80001093 400 485.10 22 RCCHPF80001094 450 1037.84 23 RCCHPF80001095 500 1239.91 24 RCCHPF80001096 600 1386.00 25 RCCHPF80001097 700 1732.50 26 RCCHPF80001099 900 2772.00 27 RCCHPF80001100 1000 3291.75 28 RCCHPF80001101 1100 3407.25 29 RCCHPF80001102 1200 4389.00
Schedule - 7 Transportation Charges : Sub Item Code No. Item Description Distance in Km. Transportation Charges in % on the Total Cost of Pipes/Collars.
E.D. VAT/CST Extra 30 RCCHPF80001148 Upto 50 Km. 19.64 31 RCCHPF80001149 Above 50 Km. Upto 100 Km. 21.00 32 RCCHPF80001150 Above 100 Km. Upto 150 Km. 28.88 33 RCCHPF80001151 Above 150 Km. Upto 200 Km. 32.00 34 RCCHPF80001152 Above 200 Km. 37.00
Note :- Technical particulars as per Annexure A enclosed 4. TERMS OF DELIVERY : F. O. R Destination (Any where in C.G.State) 5. EXCISE DUTY : Not Applicable 6. SALES TAX /VAT : Extra, as Applicable
TIN No. 22425003108 Address:-
M/s Aditya Industries, C/o Dhansiram Bhajankumar, Rupdev Market, Deviganj Road, Ambikapur Distt.- Surguja (C.G.) 497001 Mo.- 9425256300 Email- bhajan [email protected]
7. DELIVERY PERIOD : 30 Days 8. a. ANNUAL TURN OVER/ : 2010-11 Rs. 12329000.00
2011-12 Rs. 9064000.00 2012-13 Rs. 25628709.00
b. MONETARY LIMIT : Not Mentioned c. INSTALLED CAPACITY : (as per Ambikapur DTIC Registration Certificate) Description Capacity/Annum
RCC HUME PIPE 5000 Nos. 9. SLAB DISCOUNT (IF ANY) : Not Mentioned.
(Suresh Keshi) General Manager
![Page 8: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/8.jpg)
No. 8/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/AI/6467 Dated: 31-03-2015 10. PRICES : Prices are Firm and Final. 11. MINIMUM QUANTITY IN : Not Mentioned. SINGLE SUPPLY ORDER
12. STATUS OF RC HOLDING : SSI Unit
FIRM
13. REGISTRATION STATUS : Manufacturer is Registered with Ambikapur DTIC DTIC EM Part- II 220021100111 Dated 19-02-2008
14 BIS LICENSE : Not Mentioned
15. PAYING AUTHORITY : As Mentioned in supply order to be issued by Direct Demanding Officers (DDOs).
16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each consignment there-of will be made after receipt and acceptance of the stores by the consignee/interim consignee in full and good condition within 20 days as per SPR rule No.11, if the bills are in order. In case of delay in payment without any reason the department will be liable to pay interest as per prevailing bank rate. Bills are to be submitted in the prescribed form of the paying authority of purchaser / indenter and are to be supported with inspection note issued by the inspector and consignee’s Receipt Certificate .
17 INSPECTION AUTHORITY : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah) OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
18 QUALITY ASSURANCE : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR
(Suresh Keshi) General Manager
![Page 9: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/9.jpg)
No. 9/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/AI/6467 Dated: 31-03-2015 General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah) OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
19. PLACE WHERE THE STORES Manufacturer’s Factory at
ARE TO BE OFFERED FOR M/s Aditya Industries, INSPECTION C/o Dhansiram Bhajankumar, Rupdev Market,
Deviganj Road, Ambikapur Distt.- Surguja (C.G.) 497001 Mo.- 9425256300 Email- bhajan [email protected]
20 INSPECTION CHARGES : 0.60% Inspection charges + Service Tax As Applicable to be
paid extra at the time of inspection to Quality Assurance Officer which will be billed by the unit along with bill of the material and will be reimbursed by the paying authority of DDO.
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause 7, the Purchaser / DDOs may require the contractor to furnish a security deposit which shall be made after issue of the acceptance of the supply order within the period specified by the purchaser / DDOs. Such security deposit shall not ordinarily exceed 3% . The security shall be in form of Demand Drafts issued by any of the Scheduled Commercial Banks. No other form of security is to be accepted. The security deposit amount is to be refunded after successful completion of the supply.
22. Special Note : 1. Purchasing Departments / end user will ensure to sending the copy of every order to this office for Approval of inspection Agency against inspection of stores.
2. Purchasing Departments / end user will ensure to Pre Dispatch inspection of stores Through inspection agency in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to obtained the central excise invoices of Manufacturer as mentioned in the Schedule-A vide sr. no. 1-B if excise duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to execute the Integrity Pact between BUYER and BIDDER/SUPPLIEY in accordance with the letter vide no. 799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi) General Manager
![Page 10: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/10.jpg)
No. 10/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/AI/6467 Dated: 31-03-2015
Annexure 'A' CSIDC/MKD/TECH/2014-15/14
TECHNICAL PARTICULARS OF R.C.C. HUME PIPES
TSC 15-10-2014
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes (Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish / Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket & Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
The Pipes shall be of the following Sizes & Classification: Schedule- 1: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for collar joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment
Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment. 2. Tenderers may also quote rates separately for the Collars. Dimensions and Design requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003, with up-to-date amendment. Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 11: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/11.jpg)
No. 11/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/AI/6467 Dated: 31-03-2015 Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment 2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment. Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 12: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/12.jpg)
No. 12/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/AI/6467 Dated: 31-03-2015 Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter in mm) , is as per below: 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule - 8 Transportation Charges:
Sub Item Code No.
Item Description Distance in km. Transportation Charges in % on the Total Cost of Pipes/ Collars
1 Upto 50 km. 2 Above 50 km. upto 100 km. 3 Above 100 km. upto 150 km. 4 Above 150 km. upto 200 km. 5 Above 200 km.
Inspection & Testing: As per prevailing practice, the following Review of Reports shall be carried out. Review of Reports: The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review: During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively, if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the Inspecting Officer for review.
(K.N.K. Mishra) Incharge PS-VII
![Page 13: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/13.jpg)
No. 13/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/AI/6467 Dated: 31-03-2015 1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes. 2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement. 3. Manufacture’s Test Repot of Rubber Rings shall be submitted for review (incase of Pipes with Socket & Spigot ends). TESTS: As per prevailing practice, the following Tests / Checking shall be carried out. 1. Visual examination, 2. Permeability Test and 3. Three Edge Bearing Test to produce 0.25 mm crack. 4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date amendment shall be carried out if desired by the Consignee. NOTE: 1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. The length in which the pipes are to be supplied shall be as per the mutual agreement between the purchaser and the supplier. However, the recommended length above 300 mm Nominal Diameter is 2.5 meters. 4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. 6. The following information shall be shall be clearly marked on the each Finished Pipe. a. Size of Pipe, b. Class of Pipe, and c. Name of manufacture. 7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of receipt of the materials by the consignee. 8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment towards the supply of Rubber rings will be made) as per the prevailing practice, transportation cost for Pipes & Collars shall be quoted separately.
Recommended by Technical Specification Committee Dated 15-10-2014
(K.N.K. Mishra) Incharge PS-VII
![Page 14: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/14.jpg)
No. 14/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/AI/6467 Dated: 31-03-2015
SCHEDULE ‘B’ (SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi) General Manager
![Page 15: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/15.jpg)
No. 15/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/AI/6467 Dated: 31-03-2015
SCHEDULE – “D”
FORMAT FOR QUATERLY DRAWAL REPORT
Name of the Firm __________________ I- Jan-Mar Report No. __________________ II- Apr-June Rate Contract No. __________________ III- July-Sept. Date of Submission __________________ IV- Oct - Dec Total Position of Order against Rate Contract till the submission of Report. S.No. Name of
Department Quantity and Value of Orders Received (Rs.)
Quantity and Value of Orders Executed (Rs.)
Balance Quantity and Value to be Supplied (Rs.)
Reasons
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all Taxes duties and incidental b) Value of orders supplied during the quarter-Rs. Charges
2. Nil report should also be Submitted.
(Suresh Keshi) General Manager
![Page 16: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/16.jpg)
No. 16/336 S Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking) First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.) EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt) CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004 Website: www.csidc.in, Email : [email protected], [email protected]
No./CSIDC/MKD/ PS-VII /14-15/ Raipur, Dated :
Registered A/D Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/SCPI/6468 Dated: 31-03-2015 To,
M/s Surguja Cement Pipe Industries, Manendragarh Road Ambikapur Distt.- Surguja (C.G.) 497001 Mo.- 9425256300, 9826956300 Email- bhajan [email protected]
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 31-03-2015 to 01-04-2016) Ref :- (I) This Office Tender Enquiry No. PS-VII/CSIDC/MKD/102/510/14-15
(II) Bid No. 8400 Dated 07-11-2014 (III) Your Offer acceptance alongwith undertaking submitted on dated 20-03-2015
Dear Sir, You are hereby informed that your above referred tender read with subsequent letters mentioned above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction. You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the time of getting the payment. SCHEDULES ANNEXED: 1. Schedule “A” Description of Stores, Prices, Duties/Taxes . 2. Annexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions of contract (if any). 4. Schedule “C” Information to DDOs about parallel rate contracts. 5. Schedule “D” Format for Drawal Report. Encl. 13 pages
Yours faithfully,
(Suresh Keshi) General Manager
For and on behalf of the purchaser Named in CSIDC Form No.2
![Page 17: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/17.jpg)
No. 17/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/SCPI/6468 Dated: 31-03-2015 Copy to, 1. The Secretary, Chhattisgarh Vidhan Sabha ,Raipur .
2. The Registrar, Honourable High court Chhattisgarh, Bilaspur .
3. The Accountant General Chhattisgarh State, Raipur.
4. All HODs of Chhattisgarh Govt. with a request to circulate the copy of R/C to all Direct Demanding Officers of your institution against issue of purchase order (Indent) in Favour of Rate Contract Holders of CSIDC.
5. All Collectors, Chhattisgarh State against issue of purchase order (Indent) in Favour of Rate Contract holders of CSIDC.
6. The Director Treasury, Chhattisgarh Govt., Raipur with a request to circulate copy of R/C to all branches under your control .
7. (i) Director of Public Instruction Department Pension Bada Raipur (ii) Engineer in Chief PHED C.G. Neer Bhawan, Raipur (iii) The Commissioner , Local Administrator , RDA Building Raipur (iv) Engineer in Chief PWD C.G.Civil lines Raipur .
Sr. No. 1 to 7 above are requested to call for original INK-SIGNED Rate Contract for verification to their full satisfaction including validity of various documents like Registration, Tax Registration etc. before taking action i.e. against issue of purchase order in Favour of Rate Contract holders of CSIDC, pre dispatched inspection of stores, acceptance of store.
8. (i) Dy.Director (Q.A.) , DGS&D, Bhilai, Durg (C.G.). (ii) Manager (Operation) Indian Register of Shipping, Senior MIG-2, Secter A, 1st Floor,
Infront of Bank of India Indrapuri Bhopal. (iii) Chief Engineer, PDIL, 4th floor, 4/2 Karaya Road, 67 Shekespeare Sarani, Kolkata (W.B.) (iv) General Manager (Inspection) RITES Ltd., Church gate Station Road, Second Floor, M.K.
Road, Mumbai-400020 (v) Operations Manager SGS India Pvt, Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal (MP)-
462011. above (i) to (v) are requested to call for original INK-SIGNED Rate Contract For Verification to their full satisfaction including validity of various documents like Validity of Registration, BIS Registration etc. before taking action i.e. inspection of stores, as the responsibility rests with the concerned authority. For information and necessary action against Authorized Inspection Agency accorded by CSIDC for inspection of stores.
9. Incharge, Monitoring Cell, MKT-1 CSIDC, Ltd. Raipur for necessary action against inspection of stores . 10. Manager (Tender), Marketing Div., CSIDC Ltd., Raipur. He is requested to maintain a master file
of Rate Contract. 11. Computer cell, CSIDC Ltd., Raipur to release Rate Contract on CSIDC website.
12. Main file of Item- RCC HUME PIPE
(Suresh Keshi) General Manager
![Page 18: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/18.jpg)
No. 18/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/SCPI/6468 Dated: 31-03-2015
SCHEDULE “A” Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per Annexure’A’ enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Surguja Cement Pipe Industries, THE FIRM Manendragarh Road Ambikapur
Distt.- Surguja (C.G.) 497001 Mo.- 9425256300, 9826956300 Email- bhajan [email protected]
(b) NAME AND FULL ADDRESS OF :- M/s Surguja Cement Pipe Industries,
MANUFACTURER Manendragarh Road Ambikapur Distt.- Surguja (C.G.) 497001 Mo.- 9425256300, 9826956300 Email- bhajan [email protected]
(C) Category :- General 2. VALIDITY OF RATE CONTRACT :- From 31-03-2015 To 01-04-2016 4. DESCRIPTION OF ITEM- RCC HUME PIPE SPECIFICATION, UNIT RATE AS BELOW
S.No. Item Code No. Item Description Class Rate ( )
E.D. VAT/CST Extra As Applicable
Rate Per Meter
Schedule -3: Reinforced Concrete, Medium duty, Non-Pressure Pipes, Class: NP3, with ends of the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
1 RCCHPF80001045 150 183.37 2 RCCHPF80001049 300 309.35 3 RCCHPF80001050 350 415.80
4 RCCHPF80001051 400 462.00 5 RCCHPF80001052 450 1050.00 6 RCCHPF80001053 500 1155.00 7 RCCHPF80001054 600 1480.50 8 RCCHPF80001055 700 1680.00 9 RCCHPF80001056 800 2250.00 10 RCCHPF80001057 900 2936.38 11 RCCHPF80001058 1000 3052.39 12 RCCHPF80001059 1100 3465.00 13 RCCHPF80001060 1200 4378.50
Schedule -5: Reinforced Concrete, Heavy duty, Non-Pressure Pipes, Class: NP4, with ends of the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
14 RCCHPF80001087 150 202.08 15 RCCHPF80001091 300 415.80 16 RCCHPF80001092 350 462.00
(Suresh Keshi) General Manager
![Page 19: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/19.jpg)
No. 19/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/SCPI/6468 Dated: 31-03-2015
17 RCCHPF80001093 400 485.10 18 RCCHPF80001094 450 1037.84 19 RCCHPF80001095 500 1239.91 20 RCCHPF80001096 600 1386.00 21 RCCHPF80001097 700 1732.50 22 RCCHPF80001098 800 1963.50 23 RCCHPF80001099 900 2772.00 24 RCCHPF80001100 1000 3291.75 25 RCCHPF80001101 1100 3407.25 26 RCCHPF80001102 1200 4389.00
Schedule - 7 Transportation Charges : Sub Item Code No. Item Description Distance in Km. Transportation Charges in % on the Total Cost of Pipes/Collars.
E.D. VAT/CST Extra 27 RCCHPF80001148 Upto 50 Km. 19.64 28 RCCHPF80001149 Above 50 Km. Upto 100 Km. 21.00 29 RCCHPF80001150 Above 100 Km. Upto 150 Km. 28.88 30 RCCHPF80001151 Above 150 Km. Upto 200 Km. 32.00 31 RCCHPF80001152 Above 200 Km. 37.00
Note :- Technical particulars as per Annexure A enclosed 4. TERMS OF DELIVERY : F. O. R Destination (Any where in C.G.State) 5. EXCISE DUTY : Not Applicable 6. SALES TAX /VAT : Extra, as Applicable
TIN No. 22085000773 Address:-
M/s Surguja Cement Pipe Industries, Manendragarh Road Ambikapur Distt.- Surguja (C.G.) 497001 Mo.- 9425256300, 9826956300 Email- bhajan [email protected]
7. DELIVERY PERIOD : 30 Days 8. a. ANNUAL TURN OVER/ : 2010-11 Rs. 9176000.00
2011-12 Rs. 8233000.00 2012-13 Rs. 10492539.00
b. MONETARY LIMIT : Not Mentioned c. INSTALLED CAPACITY : (as per Ambikapur DTIC Registration Certificate) Description Capacity/Annum
1 R.C.C. Hume Pipe (NP2 & 3)
191175 Nos.
2 Irrigation Pipe 3 R.C.C. Septic Tank 4 Fencing Pole Chains & Stone 5 R.C.C. Boundary & K.M. Stone 6 R.C.C. Tree Guard & Singn Board 7 R.C.C. Pre Cost Canal Lining 8 Slab & Tiles 9 R.C.C. Pre Cost Structure
10 R.C.C. Fencing Poles & Cement Hollow Bricks
(Suresh Keshi) General Manager
![Page 20: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/20.jpg)
No. 20/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/SCPI/6468 Dated: 31-03-2015
9. SLAB DISCOUNT (IF ANY) : Not Mentioned. 10. PRICES : Prices are Firm and Final. 11. MINIMUM QUANTITY IN : Not Mentioned. SINGLE SUPPLY ORDER 12. STATUS OF RC HOLDING : SSI Unit
FIRM
13. REGISTRATION STATUS : Manufacturer is Registered with Ambikapur DTIC DTIC EM Part- II 220021100109 Dated 19-02-2008
14 BIS LICENSE : Not Mentioned 15. PAYING AUTHORITY : As Mentioned in supply order to be issued by Direct Demanding
Officers (DDOs). 16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each
consignment there-of will be made after receipt and acceptance of the stores by the consignee/interim consignee in full and good condition within 20 days as per SPR rule No.11, if the bills are in order. In case of delay in payment without any reason the department will be liable to pay interest as per prevailing bank rate. Bills are to be submitted in the prescribed form of the paying authority of purchaser / indenter and are to be supported with inspection note issued by the inspector and consignee’s Receipt Certificate .
17 INSPECTION AUTHORITY : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah) OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
18 QUALITY ASSURANCE : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
(Suresh Keshi)
General Manager
![Page 21: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/21.jpg)
No. 21/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/SCPI/6468 Dated: 31-03-2015 OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah) OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
19. PLACE WHERE THE STORES Manufacturer’s Factory at ARE TO BE OFFERED FOR M/s Surguja Cement Pipe Industries, INSPECTION Manendragarh Road Ambikapur
Distt.- Surguja (C.G.) 497001 Mo.- 9425256300, 9826956300 Email- bhajan [email protected]
20 INSPECTION CHARGES : 0.60% Inspection charges + Service Tax As Applicable to be
paid extra at the time of inspection to Quality Assurance Officer which will be billed by the unit along with bill of the material and will be reimbursed by the paying authority of DDO.
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause 7, the Purchaser / DDOs may require the contractor to furnish a security deposit which shall be made after issue of the acceptance of the supply order within the period specified by the purchaser / DDOs. Such security deposit shall not ordinarily exceed 3% . The security shall be in form of Demand Drafts issued by any of the Scheduled Commercial Banks. No other form of security is to be accepted. The security deposit amount is to be refunded after successful completion of the supply.
22. Special Note : 1. Purchasing Departments / end user will ensure to sending the copy of every order to this office for Approval of inspection Agency against inspection of stores.
2. Purchasing Departments / end user will ensure to Pre Dispatch inspection of stores Through inspection agency in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to obtained the central excise invoices of Manufacturer as mentioned in the Schedule-A vide sr. no. 1-B if excise duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to execute the Integrity Pact between BUYER and BIDDER/SUPPLIEY in accordance with the letter vide no. 799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi)
General Manager
![Page 22: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/22.jpg)
No. 22/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/SCPI/6468 Dated: 31-03-2015
Annexure 'A' CSIDC/MKD/TECH/2014-15/14
TECHNICAL PARTICULARS OF R.C.C. HUME PIPES
TSC 15-10-2014
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes (Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish / Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket & Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
The Pipes shall be of the following Sizes & Classification: Schedule- 1: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for collar joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment
Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment. 2. Tenderers may also quote rates separately for the Collars. Dimensions and Design requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003, with up-to-date amendment. Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 23: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/23.jpg)
No. 23/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/SCPI/6468 Dated: 31-03-2015 Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment 2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment. Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
2. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 24: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/24.jpg)
No. 24/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/SCPI/6468 Dated: 31-03-2015 Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter in mm) , is as per below: 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule - 8 Transportation Charges:
Sub Item Code No.
Item Description Distance in km. Transportation Charges in % on the Total Cost of Pipes/ Collars
1 Upto 50 km. 2 Above 50 km. upto 100 km. 3 Above 100 km. upto 150 km. 4 Above 150 km. upto 200 km. 5 Above 200 km.
Inspection & Testing: As per prevailing practice, the following Review of Reports shall be carried out. Review of Reports: The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review: During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively, if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the Inspecting Officer for review.
(K.N.K. Mishra) Incharge PS-VII
![Page 25: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/25.jpg)
No. 25/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/SCPI/6468 Dated: 31-03-2015 1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes. 2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement. 3. Manufacture’s Test Repot of Rubber Rings shall be submitted for review (incase of Pipes with Socket & Spigot ends). TESTS: As per prevailing practice, the following Tests / Checking shall be carried out. 1. Visual examination, 2. Permeability Test and 3. Three Edge Bearing Test to produce 0.25 mm crack. 4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date amendment shall be carried out if desired by the Consignee. NOTE: 1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. The length in which the pipes are to be supplied shall be as per the mutual agreement between the purchaser and the supplier. However, the recommended length above 300 mm Nominal Diameter is 2.5 meters. 4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. 6. The following information shall be shall be clearly marked on the each Finished Pipe. a. Size of Pipe, b. Class of Pipe, and c. Name of manufacture. 7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of receipt of the materials by the consignee. 8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment towards the supply of Rubber rings will be made) as per the prevailing practice, transportation cost for Pipes & Collars shall be quoted separately.
Recommended by Technical Specification Committee Dated 15-10-2014
(K.N.K. Mishra) Incharge PS-VII
![Page 26: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/26.jpg)
No. 26/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/SCPI/6468 Dated: 31-03-2015
SCHEDULE ‘B’ (SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi) General Manager
![Page 27: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/27.jpg)
No. 27/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/SCPI/6468 Dated: 31-03-2015
SCHEDULE – “D”
FORMAT FOR QUATERLY DRAWAL REPORT
Name of the Firm __________________ I- Jan-Mar Report No. __________________ II- Apr-June Rate Contract No. __________________ III- July-Sept. Date of Submission __________________ IV- Oct - Dec Total Position of Order against Rate Contract till the submission of Report. S.No. Name of
Department Quantity and Value of Orders Received (Rs.)
Quantity and Value of Orders Executed (Rs.)
Balance Quantity and Value to be Supplied (Rs.)
Reasons
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all Taxes duties and incidental b) Value of orders supplied during the quarter-Rs. Charges
2. Nil report should also be Submitted.
(Suresh Keshi) General Manager
![Page 28: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/28.jpg)
No. 28/336 Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking) First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.) EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt) CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004 Website: www.csidc.in, Email : [email protected], [email protected]
No./CSIDC/MKD/ PS-VII /14-15/ Raipur, Dated :
Registered A/D Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RH&SP/6469 Dated: 31-03-2015 To,
M/s Raigarh Hume & Spun Pipe, Near Stadium, Industrial Area Raigarh (C.G.) Mo.- 9300676323, 9301010290 Email- [email protected]
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 31-03-2015 to 01-04-2016) Ref :- (I) This Office Tender Enquiry No. PS-VII/CSIDC/MKD/102/510/14-15
(II) Bid No. 8437 Dated 19-11-2014 (III) Your Offer acceptance alongwith undertaking submitted on dated 20-03-2015
Dear Sir, You are hereby informed that your above referred tender read with subsequent letters mentioned above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction. You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the time of getting the payment. SCHEDULES ANNEXED: 1. Schedule “A” Description of Stores, Prices, Duties/Taxes . 2. Annexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions of contract (if any). 4. Schedule “C” Information to DDOs about parallel rate contracts. 5. Schedule “D” Format for Drawal Report. Encl. 13 pages
Yours faithfully,
(Suresh Keshi) General Manager
For and on behalf of the purchaser Named in CSIDC Form No.2
![Page 29: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/29.jpg)
No. 29/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RH&SP/6469 Dated: 31-03-2015 Copy to, 1. The Secretary, Chhattisgarh Vidhan Sabha ,Raipur .
2. The Registrar, Honourable High court Chhattisgarh, Bilaspur .
3. The Accountant General Chhattisgarh State, Raipur.
4. All HODs of Chhattisgarh Govt. with a request to circulate the copy of R/C to all Direct Demanding Officers of your institution against issue of purchase order (Indent) in Favour of Rate Contract Holders of CSIDC.
5. All Collectors, Chhattisgarh State against issue of purchase order (Indent) in Favour of Rate Contract holders of CSIDC.
6. The Director Treasury, Chhattisgarh Govt., Raipur with a request to circulate copy of R/C to all branches under your control .
7. (i) Director of Public Instruction Department Pension Bada Raipur (ii) Engineer in Chief PHED C.G. Neer Bhawan, Raipur (iii) The Commissioner , Local Administrator , RDA Building Raipur (iv) Engineer in Chief PWD C.G.Civil lines Raipur .
Sr. No. 1 to 7 above are requested to call for original INK-SIGNED Rate Contract for verification to their full satisfaction including validity of various documents like Registration, Tax Registration etc. before taking action i.e. against issue of purchase order in Favour of Rate Contract holders of CSIDC, pre dispatched inspection of stores, acceptance of store.
8. (i) Dy.Director (Q.A.) , DGS&D, Bhilai, Durg (C.G.). (ii) Manager (Operation) Indian Register of Shipping, Senior MIG-2, Secter A, 1st Floor,
Infront of Bank of India Indrapuri Bhopal. (iii) Chief Engineer, PDIL, 4th floor, 4/2 Karaya Road, 67 Shekespeare Sarani, Kolkata (W.B.) (iv) General Manager (Inspection) RITES Ltd., Church gate Station Road, Second Floor, M.K.
Road, Mumbai-400020 (v) Operations Manager SGS India Pvt, Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal (MP)-
462011. above (i) to (v) are requested to call for original INK-SIGNED Rate Contract For Verification to their full satisfaction including validity of various documents like Validity of Registration, BIS Registration etc. before taking action i.e. inspection of stores, as the responsibility rests with the concerned authority. For information and necessary action against Authorized Inspection Agency accorded by CSIDC for inspection of stores.
9. Incharge, Monitoring Cell, MKT-1 CSIDC, Ltd. Raipur for necessary action against inspection of stores . 10. Manager (Tender), Marketing Div., CSIDC Ltd., Raipur. He is requested to maintain a master file
of Rate Contract. 11. Computer cell, CSIDC Ltd., Raipur to release Rate Contract on CSIDC website.
12. Main file of Item- RCC HUME PIPE
(Suresh Keshi) General Manager
![Page 30: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/30.jpg)
No. 30/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RH&SP/6469 Dated: 31-03-2015
SCHEDULE “A” Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per Annexure’A’ enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Raigarh Hume & Spun Pipe, THE FIRM Near Stadium, Industrial Area Raigarh (C.G.)
Mo.- 9300676323, 9301010290 Email- [email protected]
(b) NAME AND FULL ADDRESS OF :- M/s Raigarh Hume & Spun Pipe,
MANUFACTURER Near Stadium, Industrial Area Raigarh (C.G.) Mo.- 9300676323, 9301010290 Email- [email protected]
(C) Category :- General 2. VALIDITY OF RATE CONTRACT :- From 31-03-2015 To 01-04-2016 5. DESCRIPTION OF ITEM- RCC HUME PIPE SPECIFICATION, UNIT RATE AS BELOW
S.No. Item Code No. Item Description Class Rate ( )
E.D. VAT/CST Extra As Applicable
Rate Per Meter
Schedule -3: Reinforced Concrete, Medium duty, Non-Pressure Pipes, Class: NP3, with ends of the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
1 RCCHPF80001052 450 1050.00 2 RCCHPF80001053 500 1155.00 3 RCCHPF80001054 600 1480.50 4 RCCHPF80001055 700 1680.00 5 RCCHPF80001057 900 2936.38 6 RCCHPF80001058 1000 3052.39 7 RCCHPF80001060 1200 4378.50
Schedule -5: Reinforced Concrete, Heavy duty, Non-Pressure Pipes, Class: NP4, with ends of the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
8 RCCHPF80001096 600 1386.00 9 RCCHPF80001097 700 1732.50 10 RCCHPF80001099 900 2772.00 11 RCCHPF80001100 1000 3291.75 12 RCCHPF80001102 1200 4389.00
Schedule - 7 Transportation Charges : Sub Item Code No. Item Description Distance in Km. Transportation Charges in % on the Total Cost of Pipes/Collars.
E.D. VAT/CST Extra 13 RCCHPF80001148 Upto 50 Km. 19.64 14 RCCHPF80001149 Above 50 Km. Upto 100 Km. 21.00 15 RCCHPF80001150 Above 100 Km. Upto 150 Km. 28.88
(Suresh Keshi)
General Manager
![Page 31: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/31.jpg)
No. 31/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RH&SP/6469 Dated: 31-03-2015
16 RCCHPF80001151 Above 150 Km. Upto 200 Km. 32.00 17 RCCHPF80001152 Above 200 Km. 37.00
Note :- Technical particulars as per Annexure A enclosed 4. TERMS OF DELIVERY : F. O. R Destination (Any where in C.G.State) 5. EXCISE DUTY : Not Applicable 6. SALES TAX /VAT : Extra, as Applicable
TIN No. 22375100087 Address:-
M/s Raigarh Hume & Spun Pipe, Near Stadium, Industrial Area Raigarh (C.G.) Mo.- 9300676323, 9301010290 Email- [email protected]
7. DELIVERY PERIOD : 30 Days 8. a. ANNUAL TURN OVER/ : 2011-12 Rs. 3375260.00
2012-13 Rs. 4352307.00 2013-14 Rs. 5681490.00
b. MONETARY LIMIT : Not Mentioned c. INSTALLED CAPACITY : (as per Raigarh DTIC Registration Certificate) Description Capacity/Annum
RCC HUME PIPE 29052 CFT. 9. SLAB DISCOUNT (IF ANY) : Not Mentioned. 10. PRICES : Prices are Firm and Final 11. MINIMUM QUANTITY IN : Not Mentioned. SINGLE SUPPLY ORDER 12. STATUS OF RC HOLDING : SSI Unit
FIRM 13. REGISTRATION STATUS : Manufacturer is Registered with Raigarh DTIC DTIC EM Part- II 220041100343 Dated 20-12-2010
14 BIS LICENSE : Not Mentioned 15. PAYING AUTHORITY : As Mentioned in supply order to be issued by Direct Demanding
Officers (DDOs).
16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each consignment there-of will be made after receipt and acceptance of the stores by the consignee/interim consignee in full and good condition within 20 days as per SPR rule No.11, if the bills are in order. In case of delay in payment without any reason the department will be liable to pay interest as per prevailing bank rate. Bills are to be submitted in the prescribed form of the paying authority of purchaser / indenter and are to be supported with inspection note issued by the inspector and consignee’s Receipt Certificate .
(Suresh Keshi) General Manager
![Page 32: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/32.jpg)
No. 32/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RH&SP/6469 Dated: 31-03-2015
17 INSPECTION AUTHORITY : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah) OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
18 QUALITY ASSURANCE : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah)
OR Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
19. PLACE WHERE THE STORES : Manufacturer’s Factory at ARE TO BE OFFERED FOR M/s Raigarh Hume & Spun Pipe, INSPECTION Near Stadium, Industrial Area Raigarh (C.G.)
Mo.- 9300676323, 9301010290 Email- [email protected]
20 INSPECTION CHARGES : 0.60% Inspection charges + Service Tax As Applicable to be paid extra at the time of inspection to Quality Assurance Officer which will be billed by the unit along with bill of the material and will be reimbursed by the paying authority of DDO.
(Suresh Keshi) General Manager
![Page 33: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/33.jpg)
No. 33/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RH&SP/6469 Dated: 31-03-2015
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause
7, the Purchaser / DDOs may require the contractor to furnish a security deposit which shall be made after issue of the acceptance of the supply order within the period specified by the purchaser / DDOs. Such security deposit shall not ordinarily exceed 3% . The security shall be in form of Demand Drafts issued by any of the Scheduled Commercial Banks. No other form of security is to be accepted. The security deposit amount is to be refunded after successful completion of the supply.
22. Special Note 1. Purchasing Departments / end user will ensure to sending the copy of every order to this office for Approval of inspection Agency against inspection of stores. 2. Purchasing Departments / end user will ensure to Pre
Dispatch inspection of stores Through inspection agency in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to obtained the central excise invoices of Manufacturer as mentioned in the Schedule-A vide sr. no. 1-B if excise duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to execute the Integrity Pact between BUYER and BIDDER/SUPPLIEY in accordance with the letter vide no. 799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi) General Manager
![Page 34: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/34.jpg)
No. 34/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RH&SP/6469 Dated: 31-03-2015
Annexure 'A' CSIDC/MKD/TECH/2014-15/14
TECHNICAL PARTICULARS OF R.C.C. HUME PIPES
TSC 15-10-2014
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes (Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish / Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket & Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
The Pipes shall be of the following Sizes & Classification: Schedule- 1: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for collar joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment
Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment. 2. Tenderers may also quote rates separately for the Collars. Dimensions and Design requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003, with up-to-date amendment. Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 35: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/35.jpg)
No. 35/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RH&SP/6469 Dated: 31-03-2015 Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment 2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment. Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
3. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 36: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/36.jpg)
No. 36/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RH&SP/6469 Dated: 31-03-2015 Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter in mm) , is as per below: 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule - 8 Transportation Charges:
Sub Item Code No.
Item Description Distance in km. Transportation Charges in % on the Total Cost of Pipes/ Collars
1 Upto 50 km. 2 Above 50 km. upto 100 km. 3 Above 100 km. upto 150 km. 4 Above 150 km. upto 200 km. 5 Above 200 km.
Inspection & Testing: As per prevailing practice, the following Review of Reports shall be carried out. Review of Reports: The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review: During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively, if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the Inspecting Officer for review.
(K.N.K. Mishra) Incharge PS-VII
![Page 37: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/37.jpg)
No. 37/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RH&SP/6469 Dated: 31-03-2015 1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes. 2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement. 3. Manufacture’s Test Repot of Rubber Rings shall be submitted for review (incase of Pipes with Socket & Spigot ends). TESTS: As per prevailing practice, the following Tests / Checking shall be carried out. 1. Visual examination, 2. Permeability Test and 3. Three Edge Bearing Test to produce 0.25 mm crack. 4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date amendment shall be carried out if desired by the Consignee. NOTE: 1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. The length in which the pipes are to be supplied shall be as per the mutual agreement between the purchaser and the supplier. However, the recommended length above 300 mm Nominal Diameter is 2.5 meters. 4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. 6. The following information shall be shall be clearly marked on the each Finished Pipe. a. Size of Pipe, b. Class of Pipe, and c. Name of manufacture. 7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of receipt of the materials by the consignee. 8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment towards the supply of Rubber rings will be made) as per the prevailing practice, transportation cost for Pipes & Collars shall be quoted separately.
Recommended by Technical Specification Committee Dated 15-10-2014
(K.N.K. Mishra) Incharge PS-VII
![Page 38: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/38.jpg)
No. 38/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RH&SP/6469 Dated: 31-03-2015
SCHEDULE ‘B’ (SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi) General Manager
![Page 39: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/39.jpg)
No. 39/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RH&SP/6469 Dated: 31-03-2015
SCHEDULE – “D”
FORMAT FOR QUATERLY DRAWAL REPORT
Name of the Firm __________________ I- Jan-Mar Report No. __________________ II- Apr-June Rate Contract No. __________________ III- July-Sept. Date of Submission __________________ IV- Oct - Dec Total Position of Order against Rate Contract till the submission of Report. S.No. Name of
Department Quantity and Value of Orders Received (Rs.)
Quantity and Value of Orders Executed (Rs.)
Balance Quantity and Value to be Supplied (Rs.)
Reasons
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all Taxes duties and incidental b) Value of orders supplied during the quarter-Rs. Charges
2. Nil report should also be Submitted.
(Suresh Keshi) General Manager
![Page 40: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/40.jpg)
No. 40/336 S Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking) First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.) EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt) CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004 Website: www.csidc.in, Email : [email protected], [email protected]
No./CSIDC/MKD/ PS-VII /14-15/ Raipur, Dated :
Registered A/D Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/D&C/6470 Dated: 31-03-2015 To,
M/s Dhanshri & Company , Deviganj Road Ambikapur Surguja (C.G.) 497001 Mo.- 09425580211 Ph.- 07774-235611
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 31-03-2015 to 01-04-2016) Ref :- (I) This Office Tender Enquiry No. PS-VII/CSIDC/MKD/102/510/14-15
(II) Bid No. 8427 Dated 18-11-2014 (III) Your Offer acceptance alongwith undertaking submitted on dated 25-03-2015
Dear Sir, You are hereby informed that your above referred tender read with subsequent letters mentioned above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction. You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the time of getting the payment. SCHEDULES ANNEXED: 1. Schedule “A” Description of Stores, Prices, Duties/Taxes . 2. Annexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions of contract (if any). 4. Schedule “C” Information to DDOs about parallel rate contracts. 5. Schedule “D” Format for Drawal Report. Encl. 14 pages
Yours faithfully,
(Suresh Keshi) General Manager
For and on behalf of the purchaser Named in CSIDC Form No.2
![Page 41: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/41.jpg)
No. 41/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/D&C/6470 Dated: 31-03-2015 Copy to, 1. The Secretary, Chhattisgarh Vidhan Sabha ,Raipur .
2. The Registrar, Honourable High court Chhattisgarh, Bilaspur .
3. The Accountant General Chhattisgarh State, Raipur.
4. All HODs of Chhattisgarh Govt. with a request to circulate the copy of R/C to all Direct Demanding Officers of your institution against issue of purchase order (Indent) in Favour of Rate Contract Holders of CSIDC.
5. All Collectors, Chhattisgarh State against issue of purchase order (Indent) in Favour of Rate Contract holders of CSIDC.
6. The Director Treasury, Chhattisgarh Govt., Raipur with a request to circulate copy of R/C to all branches under your control .
7. (i) Director of Public Instruction Department Pension Bada Raipur (ii) Engineer in Chief PHED C.G. Neer Bhawan, Raipur (iii) The Commissioner , Local Administrator , RDA Building Raipur (iv) Engineer in Chief PWD C.G.Civil lines Raipur .
Sr. No. 1 to 7 above are requested to call for original INK-SIGNED Rate Contract for verification to their full satisfaction including validity of various documents like Registration, Tax Registration etc. before taking action i.e. against issue of purchase order in Favour of Rate Contract holders of CSIDC, pre dispatched inspection of stores, acceptance of store.
8. (i) Dy.Director (Q.A.) , DGS&D, Bhilai, Durg (C.G.). (ii) Manager (Operation) Indian Register of Shipping, Senior MIG-2, Secter A, 1st Floor,
Infront of Bank of India Indrapuri Bhopal. (iii) Chief Engineer, PDIL, 4th floor, 4/2 Karaya Road, 67 Shekespeare Sarani, Kolkata (W.B.) (iv) General Manager (Inspection) RITES Ltd., Church gate Station Road, Second Floor, M.K.
Road, Mumbai-400020 (v) Operations Manager SGS India Pvt, Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal (MP)-
462011. above (i) to (v) are requested to call for original INK-SIGNED Rate Contract For Verification to their full satisfaction including validity of various documents like Validity of Registration, BIS Registration etc. before taking action i.e. inspection of stores, as the responsibility rests with the concerned authority. For information and necessary action against Authorized Inspection Agency accorded by CSIDC for inspection of stores.
9. Incharge, Monitoring Cell, MKT-1 CSIDC, Ltd. Raipur for necessary action against inspection of stores . 10. Manager (Tender), Marketing Div., CSIDC Ltd., Raipur. He is requested to maintain a master file
of Rate Contract. 11. Computer cell, CSIDC Ltd., Raipur to release Rate Contract on CSIDC website.
12. Main file of Item- RCC HUME PIPE
(Suresh Keshi) General Manager
![Page 42: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/42.jpg)
No. 42/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/D&C/6470 Dated: 31-03-2015
SCHEDULE “A” Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per Annexure’A’ enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Dhanshri & Company , THE FIRM Deviganj Road Ambikapur Surguja (C.G.) 497001
Mo.- 09425580211 Ph.- 07774-235611
(b) NAME AND FULL ADDRESS OF :- M/s Dhanshri & Company , MANUFACTURER Deviganj Road Ambikapur Surguja (C.G.) 497001
Mo.- 09425580211 Ph.- 07774-235611 (C) Category :- General 2. VALIDITY OF RATE CONTRACT :- From 31-03-2015 To 01-04-2016 6. DESCRIPTION OF ITEM- RCC HUME PIPE SPECIFICATION, UNIT RATE AS BELOW
S.No. Item Code No. Item Description Class Rate ( )
E.D. VAT/CST Extra As Applicable
Rate Per Meter
Schedule -1: Reinforced Concrete, Light duty, Non-Pressure Pipes, Class: NP2, with ends of the Pipes suitable for collar joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
1 RCCHPF80001002 100 104.78 2 RCCHPF80001003 150 208.95
3 RCCHPF80001004 200 202.08 4 RCCHPF80001005 225 233.27 5 RCCHPF80001006 250 241.99 6 RCCHPF80001010 450 449.06 7 RCCHPF80001011 500 600.00 8 RCCHPF80001012 600 760.91 9 RCCHPF80001013 700 903.12
10 RCCHPF80001014 800 1307.27 11 RCCHPF80001015 900 1155.00 12 RCCHPF80001016 1000 1212.75 13 RCCHPF80001018 1200 1501.50 14 RCCHPF80001019 1400 3117.25 15 RCCHPF80001020 1600 3871.93 16 RCCHPF80001021 1800 4479.42
Schedule -3: Reinforced Concrete, Medium duty, Non-Pressure Pipes, Class: NP3, with ends of the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
17 RCCHPF80001044 100 130.98 18 RCCHPF80001045 150 183.37 19 RCCHPF80001046 200 264.45 20 RCCHPF80001047 225 275.68
(Suresh Keshi) General Manager
![Page 43: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/43.jpg)
No. 43/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/D&C/6470 Dated: 31-03-2015
21 RCCHPF80001048 250 309.35 22 RCCHPF80001049 300 309.35 23 RCCHPF80001052 450 1050.00 24 RCCHPF80001053 500 1155.00 25 RCCHPF80001054 600 1480.50 26 RCCHPF80001055 700 1680.00 27 RCCHPF80001056 800 2250.00 28 RCCHPF80001057 900 2936.38 29 RCCHPF80001058 1000 3052.39 30 RCCHPF80001059 1100 3465.00 31 RCCHPF80001060 1200 4378.50 32 RCCHPF80001061 1400 5911.43 33 RCCHPF80001062 1600 7045.31 34 RCCHPF80001063 1800 7793.75
Schedule -5: Reinforced Concrete, Heavy duty, Non-Pressure Pipes, Class: NP4, with ends of the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
35 RCCHPF80001086 100 149.69 36 RCCHPF80001087 150 202.08 37 RCCHPF80001088 200 302.61 38 RCCHPF80001089 225 324.32 39 RCCHPF80001090 250 374.22 40 RCCHPF80001091 300 415.80 41 RCCHPF80001094 450 1037.84 42 RCCHPF80001095 500 1239.91 43 RCCHPF80001096 600 1386.00 44 RCCHPF80001097 700 1732.50 45 RCCHPF80001098 800 1963.50 46 RCCHPF80001099 900 2772.00 47 RCCHPF80001100 1000 3291.75 48 RCCHPF80001102 1200 4389.00 49 RCCHPF80001103 1400 5313.00 50 RCCHPF80001104 1600 7507.50
Schedule -7: Reinforced Concrete Collar for Reinforced Concrete Light duty, Non-Pressure Pipes, Class: NP2, conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Reinforced Concrete Collar for the Pipes. Class: NP2, Size (Nominal Diameter in mm.) is as per below:
51 RCCHPF80001128 100 35.81 52 RCCHPF80001129 150 42.11 53 RCCHPF80001130 200 51.98 54 RCCHPF80001131 225 61.22 55 RCCHPF80001132 250 63.53 56 RCCHPF80001133 300 76.23 57 RCCHPF80001136 450 140.33 58 RCCHPF80001137 500 187.50 59 RCCHPF80001138 600 210.00 60 RCCHPF80001139 700 226.38
(Suresh Keshi) General Manager
![Page 44: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/44.jpg)
No. 44/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/D&C/6470 Dated: 31-03-2015
61 RCCHPF80001140 800 243.71 62 RCCHPF80001141 900 315.00 63 RCCHPF80001142 1000 378.99 64 RCCHPF80001144 1200 577.50 65 RCCHPF80001145 1400 735.00 66 RCCHPF80001146 1600 840.00 67 RCCHPF80001147 1800 1050.00
Schedule - 7 Transportation Charges : Sub Item Code No. Item Description Distance in Km. Transportation Charges in % on the Total Cost of Pipes/Collars.
E.D. VAT/CST Extra 68 RCCHPF80001148 Upto 50 Km. 19.64 69 RCCHPF80001149 Above 50 Km. Upto 100 Km. 21.00 70 RCCHPF80001150 Above 100 Km. Upto 150 Km. 28.88 71 RCCHPF80001151 Above 150 Km. Upto 200 Km. 32.00 72 RCCHPF80001152 Above 200 Km. 37.00
Note :- Technical particulars as per Annexure A enclosed 4. TERMS OF DELIVERY : F. O. R Destination (Any where in C.G.State) 5. EXCISE DUTY : Not Applicable 6. SALES TAX /VAT : Extra, as Applicable
TIN No. 226855001413 Address:-
M/s Dhanshri & Company , Deviganj Road Ambikapur Surguja (C.G.) 497001 Mo.- 09425580211 Ph.- 07774-235611
7. DELIVERY PERIOD : 45 Days 8. a. ANNUAL TURN OVER/ : NM
b. MONETARY LIMIT : Not Mentioned c. INSTALLED CAPACITY : (as per Ambikapur DTIC Registration Certificate) Description Capacity/Annum
1 R.C.C. HUME PIPE
123675 Nos.
2 R.C.C. Boundary & Km Stone 3 R.C.C. Sign Board Tree Guard 4 R.C.C. Canal Lining Slab & Tiles 5 R.C.C. Dust Bin & Septic Tank 6 R.C.C. Fencing Pole
9. SLAB DISCOUNT (IF ANY) : Not Mentioned. 10. PRICES : Prices are Firm and Final 11. MINIMUM QUANTITY IN : Not Mentioned. SINGLE SUPPLY ORDER (Suresh Keshi)
General Manager
![Page 45: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/45.jpg)
No. 45/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/D&C/6470 Dated: 31-03-2015 12. STATUS OF RC HOLDING : SSI Unit
FIRM
13. REGISTRATION STATUS : Manufacturer is Registered with Ambikapur DTIC DTIC EM Part- II 220021100108 Dated 19-02-2008 14 BIS LICENSE : Not Mentioned
15. PAYING AUTHORITY : As Mentioned in supply order to be issued by Direct Demanding Officers (DDOs).
16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each consignment there-of will be made after receipt and acceptance of the stores by the consignee/interim consignee in full and good condition within 20 days as per SPR rule No.11, if the bills are in order. In case of delay in payment without any reason the department will be liable to pay interest as per prevailing bank rate. Bills are to be submitted in the prescribed form of the paying authority of purchaser / indenter and are to be supported with inspection note issued by the inspector and consignee’s Receipt Certificate .
17 INSPECTION AUTHORITY : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah) OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
18 QUALITY ASSURANCE : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah)
OR Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
(Suresh Keshi) General Manager
![Page 46: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/46.jpg)
No. 46/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/D&C/6470 Dated: 31-03-2015
19. PLACE WHERE THE STORES Manufacturer’s Factory at
ARE TO BE OFFERED FOR M/s Dhanshri & Company , INSPECTION Deviganj Road Ambikapur Surguja (C.G.) 497001
Mo.- 09425580211 Ph.- 07774-235611
20 INSPECTION CHARGES : 0.60% Inspection charges + Service Tax As Applicable to be paid extra at the time of inspection to Quality Assurance Officer which will be billed by the unit along with bill of the material and will be reimbursed by the paying authority of DDO.
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause 7, the Purchaser / DDOs may require the contractor to furnish a security deposit which shall be made after issue of the acceptance of the supply order within the period specified by the purchaser / DDOs. Such security deposit shall not ordinarily exceed 3% . The security shall be in form of Demand Drafts issued by any of the Scheduled Commercial Banks. No other form of security is to be accepted. The security deposit amount is to be refunded after successful completion of the supply.
22. Special Note 1. Purchasing Departments / end user will ensure to sending the copy of every order to this office for Approval of inspection Agency against inspection of stores. 2. Purchasing Departments / end user will ensure to Pre
Dispatch inspection of stores Through inspection agency in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to obtained the central excise invoices of Manufacturer as mentioned in the Schedule-A vide sr. no. 1-B if excise duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to execute the Integrity Pact between BUYER and BIDDER/SUPPLIEY in accordance with the letter vide no. 799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi) General Manager
![Page 47: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/47.jpg)
No. 47/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/D&C/6470 Dated: 31-03-2015
Annexure 'A' CSIDC/MKD/TECH/2014-15/14
TECHNICAL PARTICULARS OF R.C.C. HUME PIPES
TSC 15-10-2014
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes (Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish / Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket & Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
The Pipes shall be of the following Sizes & Classification: Schedule- 1: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for collar joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment
Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment. 2. Tenderers may also quote rates separately for the Collars. Dimensions and Design requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003, with up-to-date amendment. Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 48: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/48.jpg)
No. 48/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/D&C/6473 Dated: 31-03-2015 Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment 2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment. Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
4. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra)
Incharge PS-VII
![Page 49: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/49.jpg)
No. 49/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/D&C/6470 Dated: 31-03-2015 Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter in mm) , is as per below: 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule - 8 Transportation Charges:
Sub Item Code No.
Item Description Distance in km. Transportation Charges in % on the Total Cost of Pipes/ Collars
1 Upto 50 km. 2 Above 50 km. upto 100 km. 3 Above 100 km. upto 150 km. 4 Above 150 km. upto 200 km. 5 Above 200 km.
Inspection & Testing: As per prevailing practice, the following Review of Reports shall be carried out. Review of Reports: The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review: During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively, if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the Inspecting Officer for review.
(K.N.K. Mishra) Incharge PS-VII
![Page 50: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/50.jpg)
No. 50/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/D&C/6470 Dated: 31-03-2015 1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes. 2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement. 3. Manufacture’s Test Repot of Rubber Rings shall be submitted for review (incase of Pipes with Socket & Spigot ends). TESTS: As per prevailing practice, the following Tests / Checking shall be carried out. 1. Visual examination, 2. Permeability Test and 3. Three Edge Bearing Test to produce 0.25 mm crack. 4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date amendment shall be carried out if desired by the Consignee. NOTE: 1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. The length in which the pipes are to be supplied shall be as per the mutual agreement between the purchaser and the supplier. However, the recommended length above 300 mm Nominal Diameter is 2.5 meters. 4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. 6. The following information shall be shall be clearly marked on the each Finished Pipe. a. Size of Pipe, b. Class of Pipe, and c. Name of manufacture. 7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of receipt of the materials by the consignee. 8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment towards the supply of Rubber rings will be made) as per the prevailing practice, transportation cost for Pipes & Collars shall be quoted separately.
Recommended by Technical Specification Committee Dated 15-10-2014
(K.N.K. Mishra) Incharge PS-VII
![Page 51: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/51.jpg)
No. 51/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/D&C/6470 Dated: 31-03-2015
SCHEDULE ‘B’ (SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi) General Manager
![Page 52: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/52.jpg)
No. 52/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/D&C/6470 Dated: 31-03-2015
SCHEDULE – “D”
FORMAT FOR QUATERLY DRAWAL REPORT
Name of the Firm __________________ I- Jan-Mar Report No. __________________ II- Apr-June Rate Contract No. __________________ III- July-Sept. Date of Submission __________________ IV- Oct - Dec Total Position of Order against Rate Contract till the submission of Report. S.No. Name of
Department Quantity and Value of Orders Received (Rs.)
Quantity and Value of Orders Executed (Rs.)
Balance Quantity and Value to be Supplied (Rs.)
Reasons
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all Taxes duties and incidental b) Value of orders supplied during the quarter-Rs. Charges
2. Nil report should also be Submitted.
(Suresh Keshi) General Manager
![Page 53: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/53.jpg)
No. 53/336 S Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking) First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.) EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt) CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004 Website: www.csidc.in, Email : [email protected], [email protected]
No./CSIDC/MKD/ PS-VII /14-15/ Raipur, Dated :
Registered A/D Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/ACP/6471 Dated: 31-03-2015 To,
M/s Agrasen Concrete Products, Navagarh Road, Bemetara Distt- Durg (C.G.) Mo.- 9977700300
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 31-03-2015 to 01-04-2016) Ref :- (I) This Office Tender Enquiry No. PS-VII/CSIDC/MKD/102/510/14-15
(II) Bid No. 8388 Dated 26-10-2014 (III) Your Offer acceptance alongwith undertaking submitted on dated 25-03-2015
Dear Sir, You are hereby informed that your above referred tender read with subsequent letters mentioned above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction. You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the time of getting the payment. SCHEDULES ANNEXED: 1. Schedule “A” Description of Stores, Prices, Duties/Taxes . 2. Annexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions of contract (if any). 4. Schedule “C” Information to DDOs about parallel rate contracts. 5. Schedule “D” Format for Drawal Report. Encl. 13 pages
Yours faithfully,
(Suresh Keshi) General Manager
For and on behalf of the purchaser Named in CSIDC Form No.2
![Page 54: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/54.jpg)
No. 54/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/ACP/6471 Dated: 31-03-2015 Copy to, 1. The Secretary, Chhattisgarh Vidhan Sabha ,Raipur .
2. The Registrar, Honourable High court Chhattisgarh, Bilaspur .
3. The Accountant General Chhattisgarh State, Raipur.
4. All HODs of Chhattisgarh Govt. with a request to circulate the copy of R/C to all Direct Demanding Officers of your institution against issue of purchase order (Indent) in Favour of Rate Contract Holders of CSIDC.
5. All Collectors, Chhattisgarh State against issue of purchase order (Indent) in Favour of Rate Contract holders of CSIDC.
6. The Director Treasury, Chhattisgarh Govt., Raipur with a request to circulate copy of R/C to all branches under your control .
7. (i) Director of Public Instruction Department Pension Bada Raipur (ii) Engineer in Chief PHED C.G. Neer Bhawan, Raipur (iii) The Commissioner , Local Administrator , RDA Building Raipur (iv) Engineer in Chief PWD C.G.Civil lines Raipur .
Sr. No. 1 to 7 above are requested to call for original INK-SIGNED Rate Contract for verification to their full satisfaction including validity of various documents like Registration, Tax Registration etc. before taking action i.e. against issue of purchase order in Favour of Rate Contract holders of CSIDC, pre dispatched inspection of stores, acceptance of store.
8. (i) Dy.Director (Q.A.) , DGS&D, Bhilai, Durg (C.G.). (ii) Manager (Operation) Indian Register of Shipping, Senior MIG-2, Secter A, 1st Floor,
Infront of Bank of India Indrapuri Bhopal. (iii) Chief Engineer, PDIL, 4th floor, 4/2 Karaya Road, 67 Shekespeare Sarani, Kolkata (W.B.) (iv) General Manager (Inspection) RITES Ltd., Church gate Station Road, Second Floor, M.K.
Road, Mumbai-400020 (v) Operations Manager SGS India Pvt, Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal (MP)-
462011. above (i) to (v) are requested to call for original INK-SIGNED Rate Contract For Verification to their full satisfaction including validity of various documents like Validity of Registration, BIS Registration etc. before taking action i.e. inspection of stores, as the responsibility rests with the concerned authority. For information and necessary action against Authorized Inspection Agency accorded by CSIDC for inspection of stores.
9. Incharge, Monitoring Cell, MKT-1 CSIDC, Ltd. Raipur for necessary action against inspection of stores . 10. Manager (Tender), Marketing Div., CSIDC Ltd., Raipur. He is requested to maintain a master file
of Rate Contract. 11. Computer cell, CSIDC Ltd., Raipur to release Rate Contract on CSIDC website.
12. Main file of Item- RCC HUME PIPE
(Suresh Keshi) General Manager
![Page 55: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/55.jpg)
No. 55/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/ACP/6471 Dated: 31-03-2015
SCHEDULE “A” Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per Annexure’A’ enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Agrasen Concrete Products, THE FIRM Navagarh Road, Bemetara Distt- Durg (C.G.)
Mo.- 9977700300 (b) NAME AND FULL ADDRESS OF :- M/s Agrasen Concrete Products,
MANUFACTURER Navagarh Road, Bemetara Distt- Durg (C.G.) Mo.- 9977700300
(C) Category :- General 2. VALIDITY OF RATE CONTRACT :- From 31-03-2015 To 01-04-2016 7. DESCRIPTION OF ITEM- RCC HUME PIPE SPECIFICATION, UNIT RATE AS BELOW
S.No. Item Code No. Item Description Class Rate ( )
E.D. VAT/CST Extra As Applicable
Rate Per Meter
Schedule -3: Reinforced Concrete, Medium duty, Non-Pressure Pipes, Class: NP3, with ends of the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
1 RCCHPF80001052 450 1050.00 2 RCCHPF80001054 600 1480.50
3 RCCHPF80001057 900 2936.38
4 RCCHPF80001058 1000 3052.39 5 RCCHPF80001060 1200 4378.50
Schedule - 7 Transportation Charges : Sub Item Code No. Item Description Distance in Km. Transportation Charges in % on the Total Cost of Pipes/Collars.
E.D. VAT/CST Extra 6 RCCHPF80001148 Upto 50 Km. 19.64 7 RCCHPF80001149 Above 50 Km. Upto 100 Km. 21.00 8 RCCHPF80001150 Above 100 Km. Upto 150 Km. 28.88 9 RCCHPF80001151 Above 150 Km. Upto 200 Km. 32.00
10 RCCHPF80001152 Above 200 Km. 37.00 Note :- Technical particulars as per Annexure A enclosed 4. TERMS OF DELIVERY : F. O. R Destination (Any where in C.G.State) 5. EXCISE DUTY : Not Applicable 6. SALES TAX /VAT : Extra, as Applicable
TIN No. 22253700831 Address:-
M/s Agrasen Concrete Products, Navagarh Road, Bemetara Distt- Durg (C.G.) Mo.- 9977700300
(Suresh Keshi) General Manager
![Page 56: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/56.jpg)
No. 56/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/ACP/6471 Dated: 31-03-2015
7. DELIVERY PERIOD : 45 Days 8. a. ANNUAL TURN OVER/ : 2010-11 Rs. 4824009.00
2011-12 Rs. 8079084.00 2012-13 Rs. 9735988.00
b. MONETARY LIMIT : Not Mentioned c. INSTALLED CAPACITY : (as per Bemetara DTIC Registration Certificate) Description Capacity/Annum
RCC HUME PIPE 20,000 Nos.
9. SLAB DISCOUNT (IF ANY) : Not Mentioned. 10. PRICES : Prices are Firm and Final. 11. MINIMUM QUANTITY IN : Not Mentioned. SINGLE SUPPLY ORDER 12. STATUS OF RC HOLDING : Manufacturer
FIRM
13. REGISTRATION STATUS : Manufacturer is Registered with Bemetara DTIC DTIC EM Part- II 22/010/11/00513 Dated 04-04-2008
14 BIS LICENSE : Not Mentioned
15. PAYING AUTHORITY : As Mentioned in supply order to be issued by Direct Demanding Officers (DDOs).
16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each consignment there-of will be made after receipt and acceptance of the stores by the consignee/interim consignee in full and good condition within 20 days as per SPR rule No.11, if the bills are in order. In case of delay in payment without any reason the department will be liable to pay interest as per prevailing bank rate. Bills are to be submitted in the prescribed form of the paying authority of purchaser / indenter and are to be supported with inspection note issued by the inspector and consignee’s Receipt Certificate .
17 INSPECTION AUTHORITY : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah)
(Suresh Keshi) General Manager
![Page 57: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/57.jpg)
No. 57/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/ACP/6471 Dated: 31-03-2015 OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
18 QUALITY ASSURANCE : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah) OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
19. PLACE WHERE THE STORES Manufacturer’s Factory at ARE TO BE OFFERED FOR M/s Agrasen Concrete Products, INSPECTION Navagarh Road, Bemetara Distt- Durg (C.G.)
Mo.- 9977700300
20 INSPECTION CHARGES : 0.60% Inspection charges + Service Tax As Applicable to be paid extra at the time of inspection to Quality Assurance Officer which will be billed by the unit along with bill of the material and will be reimbursed by the paying authority of DDO.
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause 7, the Purchaser / DDOs may require the contractor to furnish a security deposit which shall be made after issue of the acceptance of the supply order within the period specified by the purchaser / DDOs. Such security deposit shall not ordinarily exceed 3% . The security shall be in form of Demand Drafts issued by any of the Scheduled Commercial Banks. No other form of security is to be accepted. The security deposit amount is to be refunded after successful completion of the supply.
(Suresh Keshi) General Manager
![Page 58: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/58.jpg)
No. 58/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/ACP/6471 Dated: 31-03-2015
22. Special Note 1. Purchasing Departments / end user will ensure to sending the copy of every order to this office for Approval of inspection Agency against inspection of stores. 2. Purchasing Departments / end user will ensure to Pre
Dispatch inspection of stores Through inspection agency in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to obtained the central excise invoices of Manufacturer as mentioned in the Schedule-A vide sr. no. 1-B if excise duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to execute the Integrity Pact between BUYER and BIDDER/SUPPLIEY in accordance with the letter vide no. 799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi) General Manager
![Page 59: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/59.jpg)
No. 59/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/ACP/6471 Dated: 31-03-2015
Annexure 'A' CSIDC/MKD/TECH/2014-15/14
TECHNICAL PARTICULARS OF R.C.C. HUME PIPES
TSC 15-10-2014
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes (Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish / Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket & Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
The Pipes shall be of the following Sizes & Classification: Schedule- 1: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for collar joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment
Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment. 2. Tenderers may also quote rates separately for the Collars. Dimensions and Design requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003, with up-to-date amendment. Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 60: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/60.jpg)
No. 60/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/ACP/6471 Dated: 31-03-2015 Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment 2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment. Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
5. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 61: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/61.jpg)
No. 61/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/ACP/6471 Dated: 31-03-2015 Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter in mm) , is as per below: 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule - 8 Transportation Charges:
Sub Item Code No.
Item Description Distance in km. Transportation Charges in % on the Total Cost of Pipes/ Collars
1 Upto 50 km. 2 Above 50 km. upto 100 km. 3 Above 100 km. upto 150 km. 4 Above 150 km. upto 200 km. 5 Above 200 km.
Inspection & Testing: As per prevailing practice, the following Review of Reports shall be carried out. Review of Reports: The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review: During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively, if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the Inspecting Officer for review.
(K.N.K. Mishra) Incharge PS-VII
![Page 62: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/62.jpg)
No. 62/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/ACP/6471 Dated: 31-03-2015 1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes. 2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement. 3. Manufacture’s Test Repot of Rubber Rings shall be submitted for review (incase of Pipes with Socket & Spigot ends). TESTS: As per prevailing practice, the following Tests / Checking shall be carried out. 1. Visual examination, 2. Permeability Test and 3. Three Edge Bearing Test to produce 0.25 mm crack. 4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date amendment shall be carried out if desired by the Consignee. NOTE: 1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. The length in which the pipes are to be supplied shall be as per the mutual agreement between the purchaser and the supplier. However, the recommended length above 300 mm Nominal Diameter is 2.5 meters. 4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. 6. The following information shall be shall be clearly marked on the each Finished Pipe. a. Size of Pipe, b. Class of Pipe, and c. Name of manufacture. 7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of receipt of the materials by the consignee. 8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment towards the supply of Rubber rings will be made) as per the prevailing practice, transportation cost for Pipes & Collars shall be quoted separately.
Recommended by Technical Specification Committee Dated 15-10-2014
(K.N.K. Mishra) Incharge PS-VII
![Page 63: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/63.jpg)
No. 63/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/ACP/6471 Dated: 31-03-2015
SCHEDULE ‘B’ (SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi) General Manager
![Page 64: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/64.jpg)
No. 64/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/ACP/6471 Dated: 31-03-2015
SCHEDULE – “D”
FORMAT FOR QUATERLY DRAWAL REPORT
Name of the Firm __________________ I- Jan-Mar Report No. __________________ II- Apr-June Rate Contract No. __________________ III- July-Sept. Date of Submission __________________ IV- Oct - Dec Total Position of Order against Rate Contract till the submission of Report. S.No. Name of
Department Quantity and Value of Orders Received (Rs.)
Quantity and Value of Orders Executed (Rs.)
Balance Quantity and Value to be Supplied (Rs.)
Reasons
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all Taxes duties and incidental b) Value of orders supplied during the quarter-Rs. Charges
2. Nil report should also be Submitted.
(Suresh Keshi) General Manager
![Page 65: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/65.jpg)
No. 65/336 S Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking) First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.) EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt) CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004 Website: www.csidc.in, Email : [email protected], [email protected]
No./CSIDC/MKD/ PS-VII /14-15/ Raipur, Dated :
Registered A/D Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/GCA/6472 Dated: 31-03-2015 To,
M/s Gopesh Cement Arts, Dayalband Bilaspur (C.G.) Mo.- 9300325947, 9827485186 Email- [email protected]
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 31-03-2015 to 01-04-2016) Ref :- (I) This Office Tender Enquiry No. PS-VII/CSIDC/MKD/102/510/14-15
(II) Bid No. 8391 Dated 29-10-2014 (III) Your Offer acceptance alongwith undertaking submitted on dated 25-03-2015
Dear Sir, You are hereby informed that your above referred tender read with subsequent letters mentioned above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction. You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the time of getting the payment. SCHEDULES ANNEXED: 1. Schedule “A” Description of Stores, Prices, Duties/Taxes . 2. Annexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions of contract (if any). 4. Schedule “C” Information to DDOs about parallel rate contracts. 5. Schedule “D” Format for Drawal Report. Encl. 14 pages
Yours faithfully,
(Suresh Keshi) General Manager
For and on behalf of the purchaser Named in CSIDC Form No.2
![Page 66: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/66.jpg)
No. 66/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/GCA/6472 Dated: 31-03-2015 Copy to, 1. The Secretary, Chhattisgarh Vidhan Sabha ,Raipur .
2. The Registrar, Honourable High court Chhattisgarh, Bilaspur .
3. The Accountant General Chhattisgarh State, Raipur.
4. All HODs of Chhattisgarh Govt. with a request to circulate the copy of R/C to all Direct Demanding Officers of your institution against issue of purchase order (Indent) in Favour of Rate Contract Holders of CSIDC.
5. All Collectors, Chhattisgarh State against issue of purchase order (Indent) in Favour of Rate Contract holders of CSIDC.
6. The Director Treasury, Chhattisgarh Govt., Raipur with a request to circulate copy of R/C to all branches under your control .
7. (i) Director of Public Instruction Department Pension Bada Raipur (ii) Engineer in Chief PHED C.G. Neer Bhawan, Raipur (iii) The Commissioner , Local Administrator , RDA Building Raipur (iv) Engineer in Chief PWD C.G.Civil lines Raipur .
Sr. No. 1 to 7 above are requested to call for original INK-SIGNED Rate Contract for verification to their full satisfaction including validity of various documents like Registration, Tax Registration etc. before taking action i.e. against issue of purchase order in Favour of Rate Contract holders of CSIDC, pre dispatched inspection of stores, acceptance of store.
8. (i) Dy.Director (Q.A.) , DGS&D, Bhilai, Durg (C.G.). (ii) Manager (Operation) Indian Register of Shipping, Senior MIG-2, Secter A, 1st Floor,
Infront of Bank of India Indrapuri Bhopal. (iii) Chief Engineer, PDIL, 4th floor, 4/2 Karaya Road, 67 Shekespeare Sarani, Kolkata (W.B.) (iv) General Manager (Inspection) RITES Ltd., Church gate Station Road, Second Floor, M.K.
Road, Mumbai-400020 (v) Operations Manager SGS India Pvt, Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal (MP)-
462011. above (i) to (v) are requested to call for original INK-SIGNED Rate Contract For Verification to their full satisfaction including validity of various documents like Validity of Registration, BIS Registration etc. before taking action i.e. inspection of stores, as the responsibility rests with the concerned authority. For information and necessary action against Authorized Inspection Agency accorded by CSIDC for inspection of stores.
9. Incharge, Monitoring Cell, MKT-1 CSIDC, Ltd. Raipur for necessary action against inspection of stores . 10. Manager (Tender), Marketing Div., CSIDC Ltd., Raipur. He is requested to maintain a master file
of Rate Contract. 11. Computer cell, CSIDC Ltd., Raipur to release Rate Contract on CSIDC website.
12. Main file of Item- RCC HUME PIPE
(Suresh Keshi) General Manager
![Page 67: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/67.jpg)
No. 67/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/GCA/6472 Dated: 31-03-2015
SCHEDULE “A” Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per Annexure’A’ enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Gopesh Cement Arts, THE FIRM Dayalband Bilaspur (C.G.)
Mo.- 9300325947, 9827485186 Email- [email protected]
(b) NAME AND FULL ADDRESS OF :- M/s Gopesh Cement Arts, MANUFACTURER Dayalband Bilaspur (C.G.)
Mo.- 9300325947, 9827485186 Email- [email protected]
(C) Category :- General 2. VALIDITY OF RATE CONTRACT :- From 31-03-2015 To 01-04-2016 8. DESCRIPTION OF ITEM- RCC HUME PIPE SPECIFICATION, UNIT RATE AS BELOW
S.No. Item Code No. Item Description Class Rate ( )
E.D. VAT/CST Extra As Applicable
Rate Per Meter
Schedule -1: Reinforced Concrete, Light duty, Non-Pressure Pipes, Class: NP2, with ends of the Pipes suitable for collar joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
1 RCCHPF80001003 150 208.95 2 RCCHPF80001005 225 233.27 3 RCCHPF80001006 250 241.99 4 RCCHPF80001009 400 440.33 5 RCCHPF80001011 500 600.00 6 RCCHPF80001012 600 760.91 7 RCCHPF80001013 700 903.12 8 RCCHPF80001014 800 1307.27 9 RCCHPF80001015 900 1155.00 10 RCCHPF80001016 1000 1212.75 11 RCCHPF80001018 1200 1501.50 12 RCCHPF80001019 1400 3117.25 13 RCCHPF80001020 1600 3871.93 14 RCCHPF80001021 1800 4479.42
Schedule -3: Reinforced Concrete, Medium duty, Non-Pressure Pipes, Class: NP3, with ends of the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
15 RCCHPF80001046 200 264.45 16 RCCHPF80001047 225 275.68 17 RCCHPF80001048 250 309.35 18 RCCHPF80001050 350 415.80 19 RCCHPF80001051 400 462.00
(Suresh Keshi)
General Manager
![Page 68: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/68.jpg)
No. 68/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/GCA/6472 Dated: 31-03-2015
20 RCCHPF80001052 450 1050.00 21 RCCHPF80001053 500 1155.00 22 RCCHPF80001054 600 1480.50 23 RCCHPF80001056 800 2250.00 24 RCCHPF80001057 900 2936.38 25 RCCHPF80001058 1000 3052.39 26 RCCHPF80001060 1200 4378.50 27 RCCHPF80001061 1400 5911.43 28 RCCHPF80001062 1600 7045.31 29 RCCHPF80001063 1800 7793.75
Schedule -7: Reinforced Concrete Collar for Reinforced Concrete Light duty, Non-Pressure Pipes, Class: NP2, conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Reinforced Concrete Collar for the Pipes. Class: NP2, Size (Nominal Diameter in mm.) is as per below:
30 RCCHPF80001128 100 35.81 31 RCCHPF80001129 150 42.11 32 RCCHPF80001130 200 51.98 33 RCCHPF80001131 225 61.22 34 RCCHPF80001132 250 63.53 35 RCCHPF80001133 300 76.23 36 RCCHPF80001134 350 88.94 37 RCCHPF80001135 400 128.21 38 RCCHPF80001136 450 140.33 39 RCCHPF80001137 500 187.50 40 RCCHPF80001138 600 210.00 41 RCCHPF80001139 700 226.38 42 RCCHPF80001140 800 243.71 43 RCCHPF80001141 900 315.00 44 RCCHPF80001142 1000 378.99 45 RCCHPF80001144 1200 577.50 46 RCCHPF80001145 1400 735.00 47 RCCHPF80001146 1600 840.00 48 RCCHPF80001147 1800 1050.00
Schedule - 7 Transportation Charges : Sub Item Code No. Item Description Distance in Km. Transportation Charges in % on the Total Cost of Pipes/Collars.
E.D. VAT/CST Extra 49 RCCHPF80001148 Upto 50 Km. 19.64 50 RCCHPF80001149 Above 50 Km. Upto 100 Km. 21.00 51 RCCHPF80001150 Above 100 Km. Upto 150 Km. 28.88 52 RCCHPF80001151 Above 150 Km. Upto 200 Km. 32.00 53 RCCHPF80001152 Above 200 Km. 37.00
Note :- Technical particulars as per Annexure A enclosed 4. TERMS OF DELIVERY : F. O. R Destination (Any where in C.G.State) 5. EXCISE DUTY : Not Applicable
(Suresh Keshi) General Manager
![Page 69: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/69.jpg)
No. 69/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/GCA/6472 Dated: 31-03-2015 6. SALES TAX /VAT : Extra, as Applicable
TIN No. 22634301925 Address:-
M/s Gopesh Cement Arts, Dayalband Bilaspur (C.G.) Mo.- 9300325947, 9827485186 Email- [email protected]
7. DELIVERY PERIOD : 45 Days 8. a. ANNUAL TURN OVER/ : 2011-12 Rs. 9716851.00
2012-13 Rs. 7721883.00 2013-14 Rs. 7662998.00
b. MONETARY LIMIT : Not Mentioned c. INSTALLED CAPACITY : (as per Bilaspur DTIC Registration Certificate) Description Capacity/Annum
RCC HUME PIPE 34560 Nos. 9. SLAB DISCOUNT (IF ANY) : Not Mentioned. 10. PRICES : Prices are Firm and Final. 11. MINIMUM QUANTITY IN : Not Mentioned. SINGLE SUPPLY ORDER 12. STATUS OF RC HOLDING : Manufacturer
FIRM 13. REGISTRATION STATUS : Manufacturer is Registered with Bilaspur DTIC DTIC EM Part-II 220071200231 Dated 24-01-2009
14 BIS LICENSE : Not Mentioned
15. PAYING AUTHORITY : As Mentioned in supply order to be issued by Direct Demanding Officers (DDOs).
16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each consignment there-of will be made after receipt and acceptance of the stores by the consignee/interim consignee in full and good condition within 20 days as per SPR rule No.11, if the bills are in order. In case of delay in payment without any reason the department will be liable to pay interest as per prevailing bank rate. Bills are to be submitted in the prescribed form of the paying authority of purchaser / indenter and are to be supported with inspection note issued by the inspector and consignee’s Receipt Certificate .
17 INSPECTION AUTHORITY : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
(Suresh Keshi) General Manager
![Page 70: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/70.jpg)
No. 70/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/GCA/6472 Dated: 31-03-2015
OR
Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah) OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
18 QUALITY ASSURANCE : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate
Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah)
OR Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
19. PLACE WHERE THE STORES Manufacturer’s Factory at ARE TO BE OFFERED FOR M/s Gopesh Cement Arts, INSPECTION Dayalband Bilaspur (C.G.)
Mo.- 9300325947, 9827485186 Email- [email protected]
20 INSPECTION CHARGES : 0.60% Inspection charges + Service Tax As Applicable to be
paid extra at the time of inspection to Quality Assurance Officer which will be billed by the unit along with bill of the material and will be reimbursed by the paying authority of DDO.
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause
7, the Purchaser / DDOs may require the contractor to furnish a security deposit which shall be made after issue of the acceptance of the supply order within the period specified by the purchaser / DDOs. Such security deposit shall not ordinarily exceed 3% . The security shall be in form of Demand Drafts issued by any of the Scheduled Commercial Banks. No other form of security is to be accepted. The security deposit amount is to be refunded after successful completion of the supply.
(Suresh Keshi) General Manager
![Page 71: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/71.jpg)
No. 71/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/GCA/6472 Dated: 31-03-2015
22. Special Note 1. Purchasing Departments / end user will ensure to sending the copy of every order to this office for Approval of inspection Agency against inspection of stores. 2. Purchasing Departments / end user will ensure to Pre
Dispatch inspection of stores Through inspection agency in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to obtained the central excise invoices of Manufacturer as mentioned in the Schedule-A vide sr. no. 1-B if excise duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to execute the Integrity Pact between BUYER and BIDDER/SUPPLIEY in accordance with the letter vide no. 799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi) General Manager
![Page 72: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/72.jpg)
No. 72/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/GCA/6472 Dated: 31-03-2015
Annexure 'A' CSIDC/MKD/TECH/2014-15/14
TECHNICAL PARTICULARS OF R.C.C. HUME PIPES
TSC 15-10-2014
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes (Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish / Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket & Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
The Pipes shall be of the following Sizes & Classification: Schedule- 1: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for collar joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment
Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment. 2. Tenderers may also quote rates separately for the Collars. Dimensions and Design requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003, with up-to-date amendment. Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 73: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/73.jpg)
No. 73/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/GCA/6472 Dated: 31-03-2015 Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment 2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment. Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
6. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 74: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/74.jpg)
No. 74/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/GCA/6472 Dated: 31-03-2015 Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter in mm) , is as per below: 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule - 8 Transportation Charges:
Sub Item Code No.
Item Description Distance in km. Transportation Charges in % on the Total Cost of Pipes/ Collars
1 Upto 50 km. 2 Above 50 km. upto 100 km. 3 Above 100 km. upto 150 km. 4 Above 150 km. upto 200 km. 5 Above 200 km.
Inspection & Testing: As per prevailing practice, the following Review of Reports shall be carried out. Review of Reports: The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review: During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively, if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the Inspecting Officer for review.
(K.N.K. Mishra) Incharge PS-VII
![Page 75: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/75.jpg)
No. 75/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/GCA/6472 Dated: 31-03-2015 1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes. 2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement. 3. Manufacture’s Test Repot of Rubber Rings shall be submitted for review (incase of Pipes with Socket & Spigot ends). TESTS: As per prevailing practice, the following Tests / Checking shall be carried out. 1. Visual examination, 2. Permeability Test and 3. Three Edge Bearing Test to produce 0.25 mm crack. 4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date amendment shall be carried out if desired by the Consignee. NOTE: 1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. The length in which the pipes are to be supplied shall be as per the mutual agreement between the purchaser and the supplier. However, the recommended length above 300 mm Nominal Diameter is 2.5 meters. 4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. 6. The following information shall be shall be clearly marked on the each Finished Pipe. a. Size of Pipe, b. Class of Pipe, and c. Name of manufacture. 7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of receipt of the materials by the consignee. 8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment towards the supply of Rubber rings will be made) as per the prevailing practice, transportation cost for Pipes & Collars shall be quoted separately.
Recommended by Technical Specification Committee Dated 15-10-2014
(K.N.K. Mishra) Incharge PS-VII
![Page 76: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/76.jpg)
No. 76/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/GCA/6472 Dated: 31-03-2015
SCHEDULE ‘B’ (SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi) General Manager
![Page 77: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/77.jpg)
No. 77/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/GCA/6472 Dated: 31-03-2015
SCHEDULE – “D”
FORMAT FOR QUATERLY DRAWAL REPORT
Name of the Firm __________________ I- Jan-Mar Report No. __________________ II- Apr-June Rate Contract No. __________________ III- July-Sept. Date of Submission __________________ IV- Oct - Dec Total Position of Order against Rate Contract till the submission of Report. S.No. Name of
Department Quantity and Value of Orders Received (Rs.)
Quantity and Value of Orders Executed (Rs.)
Balance Quantity and Value to be Supplied (Rs.)
Reasons
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all Taxes duties and incidental b) Value of orders supplied during the quarter-Rs. Charges
2. Nil report should also be Submitted.
(Suresh Keshi) General Manager
![Page 78: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/78.jpg)
No. 78/336 S Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking) First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.) EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt) CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004 Website: www.csidc.in, Email : [email protected], [email protected]
No./CSIDC/MKD/ PS-VII /14-15/ Raipur, Dated :
Registered A/D Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RBK&C/6473 Dated: 31-03-2015 To,
M/s Radheshyam Benishyam Kesary & Co., Dayalband Bilaspur (C.G.) Mo.- 9827167998 , 9300333354 Email- [email protected]
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 31-03-2015 to 01-04-2016) Ref :- (I) This Office Tender Enquiry No. PS-VII/CSIDC/MKD/102/510/14-15
(II) Bid No. 8386 Dated 18-10-2014 (III) Your Offer acceptance alongwith undertaking submitted on dated 25-03-2015
Dear Sir, You are hereby informed that your above referred tender read with subsequent letters mentioned above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction. You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the time of getting the payment. SCHEDULES ANNEXED: 1. Schedule “A” Description of Stores, Prices, Duties/Taxes . 2. Annexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions of contract (if any). 4. Schedule “C” Information to DDOs about parallel rate contracts. 5. Schedule “D” Format for Drawal Report. Encl. 14 pages
Yours faithfully,
(Suresh Keshi) General Manager
For and on behalf of the purchaser Named in CSIDC Form No.2
![Page 79: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/79.jpg)
No. 79/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RBK&C/6473 Dated: 31-03-2015 Copy to, 1. The Secretary, Chhattisgarh Vidhan Sabha ,Raipur .
2. The Registrar, Honourable High court Chhattisgarh, Bilaspur .
3. The Accountant General Chhattisgarh State, Raipur.
4. All HODs of Chhattisgarh Govt. with a request to circulate the copy of R/C to all Direct Demanding Officers of your institution against issue of purchase order (Indent) in Favour of Rate Contract Holders of CSIDC.
5. All Collectors, Chhattisgarh State against issue of purchase order (Indent) in Favour of Rate Contract holders of CSIDC.
6. The Director Treasury, Chhattisgarh Govt., Raipur with a request to circulate copy of R/C to all branches under your control .
7. (i) Director of Public Instruction Department Pension Bada Raipur (ii) Engineer in Chief PHED C.G. Neer Bhawan, Raipur (iii) The Commissioner , Local Administrator , RDA Building Raipur (iv) Engineer in Chief PWD C.G.Civil lines Raipur .
Sr. No. 1 to 7 above are requested to call for original INK-SIGNED Rate Contract for verification to their full satisfaction including validity of various documents like Registration, Tax Registration etc. before taking action i.e. against issue of purchase order in Favour of Rate Contract holders of CSIDC, pre dispatched inspection of stores, acceptance of store.
8. (i) Dy.Director (Q.A.) , DGS&D, Bhilai, Durg (C.G.). (ii) Manager (Operation) Indian Register of Shipping, Senior MIG-2, Secter A, 1st Floor,
Infront of Bank of India Indrapuri Bhopal. (iii) Chief Engineer, PDIL, 4th floor, 4/2 Karaya Road, 67 Shekespeare Sarani, Kolkata (W.B.) (iv) General Manager (Inspection) RITES Ltd., Church gate Station Road, Second Floor, M.K.
Road, Mumbai-400020 (v) Operations Manager SGS India Pvt, Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal (MP)-
462011. above (i) to (v) are requested to call for original INK-SIGNED Rate Contract For Verification to their full satisfaction including validity of various documents like Validity of Registration, BIS Registration etc. before taking action i.e. inspection of stores, as the responsibility rests with the concerned authority. For information and necessary action against Authorized Inspection Agency accorded by CSIDC for inspection of stores.
9. Incharge, Monitoring Cell, MKT-1 CSIDC, Ltd. Raipur for necessary action against inspection of stores . 10. Manager (Tender), Marketing Div., CSIDC Ltd., Raipur. He is requested to maintain a master file
of Rate Contract. 11. Computer cell, CSIDC Ltd., Raipur to release Rate Contract on CSIDC website.
12. Main file of Item- RCC HUME PIPE
(Suresh Keshi) General Manager
![Page 80: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/80.jpg)
No. 80/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RBK&C/6473 Dated: 31-03-2015
SCHEDULE “A” Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per Annexure’A’ enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Radheshyam Benishyam Kesary & Co., THE FIRM Dayalband Bilaspur (C.G.)
Mo.- 9827167998, 9300333354 Email- [email protected]
(b) NAME AND FULL ADDRESS OF :- M/s Radheshyam Benishyam Kesary & Co., MANUFACTURER Dayalband Bilaspur (C.G.)
Mo.- 9827167998 , 9300333354 Email- [email protected]
(C) Category :- General 2. VALIDITY OF RATE CONTRACT :- From 31-03-2015 To 01-04-2016 9. DESCRIPTION OF ITEM- RCC HUME PIPE SPECIFICATION, UNIT RATE AS BELOW
S.No. Item Code No. Item Description Class Rate ( )
E.D. VAT/CST Extra As
Applicable Rate Per Meter
Schedule -1: Reinforced Concrete, Light duty, Non-Pressure Pipes, Class: NP2, with ends of the Pipes suitable for collar joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
1 RCCHPF80001003 150 208.95 2 RCCHPF80001006 250 241.99 3 RCCHPF80001009 400 440.33 4 RCCHPF80001011 500 600.00 5 RCCHPF80001012 600 760.91 6 RCCHPF80001013 700 903.12 7 RCCHPF80001014 800 1307.27 8 RCCHPF80001015 900 1155.00 9 RCCHPF80001016 1000 1212.75 10 RCCHPF80001018 1200 1501.50 11 RCCHPF80001019 1400 3117.25 12 RCCHPF80001020 1600 3871.93 13 RCCHPF80001021 1800 4479.42
Schedule -3: Reinforced Concrete, Medium duty, Non-Pressure Pipes, Class: NP3, with ends of the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
14 RCCHPF80001046 200 264.45 15 RCCHPF80001047 225 275.68 16 RCCHPF80001048 250 309.35 17 RCCHPF80001050 350 415.80 18 RCCHPF80001051 400 462.00
(Suresh Keshi) General Manager
![Page 81: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/81.jpg)
No. 81/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RBK&C/6473 Dated: 31-03-2015
19 RCCHPF80001052 450 1050.00 20 RCCHPF80001053 500 1155.00 21 RCCHPF80001054 600 1480.50 22 RCCHPF80001055 700 1680.00 23 RCCHPF80001056 800 2250.00 24 RCCHPF80001057 900 2936.38 25 RCCHPF80001058 1000 3052.39 26 RCCHPF80001059 1100 3465.00 27 RCCHPF80001060 1200 4378.50 28 RCCHPF80001061 1400 5911.43 29 RCCHPF80001062 1600 7045.31 30 RCCHPF80001063 1800 7793.75
Schedule -7: Reinforced Concrete Collar for Reinforced Concrete Light duty, Non-Pressure Pipes, Class: NP2, conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Reinforced Concrete Collar for the Pipes. Class: NP2, Size (Nominal Diameter in mm.) is as per below:
31 RCCHPF80001128 100 35.81 32 RCCHPF80001129 150 42.11 33 RCCHPF80001130 200 51.98 34 RCCHPF80001131 225 61.22 35 RCCHPF80001132 250 63.53 36 RCCHPF80001133 300 76.23 37 RCCHPF80001134 350 88.94 38 RCCHPF80001135 400 128.21 39 RCCHPF80001136 450 140.33 40 RCCHPF80001137 500 187.50 41 RCCHPF80001138 600 210.00 42 RCCHPF80001139 700 226.38 43 RCCHPF80001140 800 243.71 44 RCCHPF80001141 900 315.00 45 RCCHPF80001142 1000 378.99 46 RCCHPF80001143 1100 525.00 47 RCCHPF80001144 1200 577.50 48 RCCHPF80001145 1400 735.00 49 RCCHPF80001146 1600 840.00 50 RCCHPF80001147 1800 1050.00
Schedule - 7 Transportation Charges : Sub Item Code No. Item Description Distance in Km. Transportation Charges in % on the Total Cost of Pipes/Collars.
E.D. VAT/CST Extra 51 RCCHPF80001148 Upto 50 Km. 19.64 52 RCCHPF80001149 Above 50 Km. Upto 100 Km. 21.00 53 RCCHPF80001150 Above 100 Km. Upto 150 Km. 28.88 54 RCCHPF80001151 Above 150 Km. Upto 200 Km. 32.00 55 RCCHPF80001152 Above 200 Km. 37.00
Note :- Technical particulars as per Annexure A enclosed 4. TERMS OF DELIVERY : F. O. R Destination (Any where in C.G.State) 5. EXCISE DUTY : Not Applicable
(Suresh Keshi) General Manager
![Page 82: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/82.jpg)
No. 82/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RBK&C/6473 Dated: 31-03-2015 6. SALES TAX /VAT : Extra, as Applicable
TIN No. 22614300869 Address:-
M/s Radheshyam Benishyam Kesary & Co., Dayalband Bilaspur (C.G.) Mo.- 9827167998, 9300333354 Email- [email protected]
7. DELIVERY PERIOD : 45 Days 8. a. ANNUAL TURN OVER : 2011-12 Rs. 8549590.00 2012-13 Rs. 9731137.00 2013-14 Rs. 9894925.00
b. MONETARY LIMIT : Not Mentioned c. INSTALLED CAPACITY : (as per Bilaspur DTIC Registration Certificate) Description Capacity/Annum
1 Rcc Hume Pipe NP2, NP3, NP4 45510 Nos. 2 Rcc Hume Pipe Half Round
9. SLAB DISCOUNT (IF ANY) : Not Mentioned. 10. PRICES : Prices are Firm and Final. 11. MINIMUM QUANTITY IN : Not Mentioned. SINGLE SUPPLY ORDER 12. STATUS OF RC HOLDING : Manufacturer
FIRM
13. REGISTRATION STATUS : Manufacturer is Registered with DTIC Bilaspur DTIC EM PART-II 220071200230 Dated 23-01-2009
14 BIS LICENSE : Not Mentioned
15. PAYING AUTHORITY : As Mentioned in supply order to be issued by Direct Demanding Officers (DDOs).
16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each consignment there-of will be made after receipt and acceptance of the stores by the consignee/interim consignee in full and good condition within 20 days as per SPR rule No.11, if the bills are in order. In case of delay in payment without any reason the department will be liable to pay interest as per prevailing bank rate. Bills are to be submitted in the prescribed form of the paying authority of purchaser / indenter and are to be supported with inspection note issued by the inspector and consignee’s Receipt Certificate .
(Suresh Keshi) General Manager
![Page 83: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/83.jpg)
No. 83/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RBK&C/6473 Dated: 31-03-2015
17 INSPECTION AUTHORITY : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah) OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
18 QUALITY ASSURANCE : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah) OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
19. PLACE WHERE THE STORES Manufacturer’s Factory at
ARE TO BE OFFERED FOR M/s Radheshyam Benishyam Kesary & Co., INSPECTION Dayalband Bilaspur (C.G.)
Mo.- 9827167998, 9300333354 Email- [email protected]
20 INSPECTION CHARGES : 0.60% Inspection charges + Service Tax As Applicable to be paid extra at the time of inspection to Quality Assurance Officer which will be billed by the unit along with bill of the material and will be reimbursed by the paying authority of DDO.
(Suresh Keshi)
General Manager
![Page 84: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/84.jpg)
No. 84/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RBK&C/6473 Dated: 31-03-2015
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause
7, the Purchaser / DDOs may require the contractor to furnish a security deposit which shall be made after issue of the acceptance of the supply order within the period specified by the purchaser / DDOs. Such security deposit shall not ordinarily exceed 3% . The security shall be in form of Demand Drafts issued by any of the Scheduled Commercial Banks. No other form of security is to be accepted. The security deposit amount is to be refunded after successful completion of the supply.
22. Special Note 1. Purchasing Departments / end user will ensure to sending the copy of every order to this office for Approval of inspection Agency against inspection of stores. 2. Purchasing Departments / end user will ensure to Pre
Dispatch inspection of stores Through inspection agency in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to obtained the central excise invoices of Manufacturer as mentioned in the Schedule-A vide sr. no. 1-B if excise duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to execute the Integrity Pact between BUYER and BIDDER/SUPPLIEY in accordance with the letter vide no. 799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi) General Manager
![Page 85: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/85.jpg)
No. 85/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RBK&C/6473 Dated: 31-03-2015
Annexure 'A' CSIDC/MKD/TECH/2014-15/14
TECHNICAL PARTICULARS OF R.C.C. HUME PIPES
TSC 15-10-2014
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes (Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish / Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket & Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
The Pipes shall be of the following Sizes & Classification: Schedule- 1: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for collar joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment
Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment. 2. Tenderers may also quote rates separately for the Collars. Dimensions and Design requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003, with up-to-date amendment. Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 86: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/86.jpg)
No. 86/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RBK&C/6473 Dated: 31-03-2015 Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment 2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment. Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
7. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 87: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/87.jpg)
No. 87/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RBK&C/6473 Dated: 31-03-2015 Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter in mm) , is as per below: 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule - 8 Transportation Charges:
Sub Item Code No.
Item Description Distance in km. Transportation Charges in % on the Total Cost of Pipes/ Collars
1 Upto 50 km. 2 Above 50 km. upto 100 km. 3 Above 100 km. upto 150 km. 4 Above 150 km. upto 200 km. 5 Above 200 km.
Inspection & Testing: As per prevailing practice, the following Review of Reports shall be carried out. Review of Reports: The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review: During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively, if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the Inspecting Officer for review.
(K.N.K. Mishra) Incharge PS-VII
![Page 88: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/88.jpg)
No. 88/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RBK&C/6473 Dated: 31-03-2015 1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes. 2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement. 3. Manufacture’s Test Repot of Rubber Rings shall be submitted for review (incase of Pipes with Socket & Spigot ends). TESTS: As per prevailing practice, the following Tests / Checking shall be carried out. 1. Visual examination, 2. Permeability Test and 3. Three Edge Bearing Test to produce 0.25 mm crack. 4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date amendment shall be carried out if desired by the Consignee. NOTE: 1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. The length in which the pipes are to be supplied shall be as per the mutual agreement between the purchaser and the supplier. However, the recommended length above 300 mm Nominal Diameter is 2.5 meters. 4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. 6. The following information shall be shall be clearly marked on the each Finished Pipe. a. Size of Pipe, b. Class of Pipe, and c. Name of manufacture. 7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of receipt of the materials by the consignee. 8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment towards the supply of Rubber rings will be made) as per the prevailing practice, transportation cost for Pipes & Collars shall be quoted separately.
Recommended by Technical Specification Committee Dated 15-10-2014
(K.N.K. Mishra) Incharge PS-VII
![Page 89: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/89.jpg)
No. 89/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RBK&C/6473 Dated: 31-03-2015
SCHEDULE ‘B’ (SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi) General Manager
![Page 90: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/90.jpg)
No. 90/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RBK&C/6473 Dated: 31-03-2015
SCHEDULE – “D”
FORMAT FOR QUATERLY DRAWAL REPORT
Name of the Firm __________________ I- Jan-Mar Report No. __________________ II- Apr-June Rate Contract No. __________________ III- July-Sept. Date of Submission __________________ IV- Oct - Dec Total Position of Order against Rate Contract till the submission of Report. S.No. Name of
Department Quantity and Value of Orders Received (Rs.)
Quantity and Value of Orders Executed (Rs.)
Balance Quantity and Value to be Supplied (Rs.)
Reasons
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all Taxes duties and incidental b) Value of orders supplied during the quarter-Rs. Charges
2. Nil report should also be Submitted.
(Suresh Keshi) General Manager
![Page 91: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/91.jpg)
No. 91/336 S Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking) First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.) EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt) CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004 Website: www.csidc.in, Email : [email protected], [email protected]
No./CSIDC/MKD/ PS-VII /14-15/ Raipur, Dated :
Registered A/D Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/BCP/6474 Dated: 31-03-2015 To,
M/s Bilaspur Cement Products, C/o Shri Sai Teles & Sanitary Main Road Tarwa Naka Bilaspur (C.G.) 495001 Mo.- 9425219302, 9893968974 Ph.-07752-410302
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 31-03-2015 to 01-04-2016) Ref :- (I) This Office Tender Enquiry No. PS-VII/CSIDC/MKD/102/510/14-15
(II) Bid No. 8416 Dated 11-11-2014 (III) Your Offer acceptance alongwith undertaking submitted on dated 25-03-2015
Dear Sir, You are hereby informed that your above referred tender read with subsequent letters mentioned above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction. You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the time of getting the payment. SCHEDULES ANNEXED: 1. Schedule “A” Description of Stores, Prices, Duties/Taxes . 2. Annexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions of contract (if any). 4. Schedule “C” Information to DDOs about parallel rate contracts. 5. Schedule “D” Format for Drawal Report. Encl. 13 pages
Yours faithfully,
(Suresh Keshi) General Manager
For and on behalf of the purchaser Named in CSIDC Form No.2
![Page 92: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/92.jpg)
No. 92/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/BCP/6474 Dated: 31-03-2015 Copy to, 1. The Secretary, Chhattisgarh Vidhan Sabha ,Raipur .
2. The Registrar, Honourable High court Chhattisgarh, Bilaspur .
3. The Accountant General Chhattisgarh State, Raipur.
4. All HODs of Chhattisgarh Govt. with a request to circulate the copy of R/C to all Direct Demanding Officers of your institution against issue of purchase order (Indent) in Favour of Rate Contract Holders of CSIDC.
5. All Collectors, Chhattisgarh State against issue of purchase order (Indent) in Favour of Rate Contract holders of CSIDC.
6. The Director Treasury, Chhattisgarh Govt., Raipur with a request to circulate copy of R/C to all branches under your control .
7. (i) Director of Public Instruction Department Pension Bada Raipur (ii) Engineer in Chief PHED C.G. Neer Bhawan, Raipur (iii) The Commissioner , Local Administrator , RDA Building Raipur (iv) Engineer in Chief PWD C.G.Civil lines Raipur .
Sr. No. 1 to 7 above are requested to call for original INK-SIGNED Rate Contract for verification to their full satisfaction including validity of various documents like Registration, Tax Registration etc. before taking action i.e. against issue of purchase order in Favour of Rate Contract holders of CSIDC, pre dispatched inspection of stores, acceptance of store.
8. (i) Dy.Director (Q.A.) , DGS&D, Bhilai, Durg (C.G.). (ii) Manager (Operation) Indian Register of Shipping, Senior MIG-2, Secter A, 1st Floor,
Infront of Bank of India Indrapuri Bhopal. (iii) Chief Engineer, PDIL, 4th floor, 4/2 Karaya Road, 67 Shekespeare Sarani, Kolkata (W.B.) (iv) General Manager (Inspection) RITES Ltd., Church gate Station Road, Second Floor, M.K.
Road, Mumbai-400020 (v) Operations Manager SGS India Pvt, Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal (MP)-
462011. above (i) to (v) are requested to call for original INK-SIGNED Rate Contract For Verification to their full satisfaction including validity of various documents like Validity of Registration, BIS Registration etc. before taking action i.e. inspection of stores, as the responsibility rests with the concerned authority. For information and necessary action against Authorized Inspection Agency accorded by CSIDC for inspection of stores.
9. Incharge, Monitoring Cell, MKT-1 CSIDC, Ltd. Raipur for necessary action against inspection of stores . 10. Manager (Tender), Marketing Div., CSIDC Ltd., Raipur. He is requested to maintain a master file
of Rate Contract. 11. Computer cell, CSIDC Ltd., Raipur to release Rate Contract on CSIDC website.
12. Main file of Item- RCC HUME PIPE
(Suresh Keshi) General Manager
![Page 93: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/93.jpg)
No. 93/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/BCP/6474 Dated: 31-03-2015
SCHEDULE “A” Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per Annexure’A’ enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Bilaspur Cement Products, THE FIRM C/o Shri Sai Teles & Sanitary Main Road
Tarwa Naka Bilaspur (C.G.) 495001 Mo.- 9425219302, 9893968974 Ph.-07752-410302
(b) NAME AND FULL ADDRESS OF :- M/s Bilaspur Cement Products, MANUFACTURER C/o Shri Sai Teles & Sanitary Main Road
Tarwa Naka Bilaspur (C.G.) 495001 Mo.- 9425219302, 9893968974 Ph.-07752-410302
(C) Category :- General 2. VALIDITY OF RATE CONTRACT :- From 31-03-2015 To 01-04-2016 10. DESCRIPTION OF ITEM- RCC HUME PIPE SPECIFICATION, UNIT RATE AS BELOW
S.No. Item Code No. Item Description Class Rate ( )
E.D. VAT/CST Extra As Applicable
Rate Per Meter
Schedule -1: Reinforced Concrete, Light duty, Non-Pressure Pipes, Class: NP2, with ends of the Pipes suitable for collar joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
1 RCCHPF80001010 450 449.06 2 RCCHPF80001012 600 760.91 3 RCCHPF80001015 900 1155.00
4 RCCHPF80001018 1200 1501.50 5 RCCHPF80001019 1400 3117.25
Schedule -3: Reinforced Concrete, Medium duty, Non-Pressure Pipes, Class: NP3, with ends of the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
6 RCCHPF80001049 300 309.35 7 RCCHPF80001052 450 1050.00 8 RCCHPF80001054 600 1480.50 9 RCCHPF80001057 900 2936.38 10 RCCHPF80001058 1000 3052.39 11 RCCHPF80001060 1200 4378.50
Schedule -5: Reinforced Concrete, Heavy duty, Non-Pressure Pipes, Class: NP4, with ends of the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
12 RCCHPF80001091 300 415.80 13 RCCHPF80001094 450 1037.84 14 RCCHPF80001096 600 1386.00
(Suresh Keshi) General Manager
![Page 94: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/94.jpg)
No. 94/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/BCP/6474 Dated: 31-03-2015
15 RCCHPF80001099 900 2772.00 16 RCCHPF80001100 1000 3291.75 17 RCCHPF80001102 1200 4389.00
Schedule -7: Reinforced Concrete Collar for Reinforced Concrete Light duty, Non-Pressure Pipes, Class: NP2, conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Reinforced Concrete Collar for the Pipes. Class: NP2, Size (Nominal Diameter in mm.) is as per below:
18 RCCHPF80001133 300 76.23 19 RCCHPF80001136 450 140.33 20 RCCHPF80001138 600 210.00 21 RCCHPF80001141 900 315.00 22 RCCHPF80001144 1200 577.50
Schedule - 7 Transportation Charges : Sub Item Code No. Item Description Distance in Km. Transportation Charges in % on the Total Cost of Pipes/Collars.
E.D. VAT/CST Extra 23 RCCHPF80001148 Upto 50 Km. 19.64 24 RCCHPF80001149 Above 50 Km. Upto 100 Km. 21.00 25 RCCHPF80001150 Above 100 Km. Upto 150 Km. 28.88 26 RCCHPF80001151 Above 150 Km. Upto 200 Km. 32.00 27 RCCHPF80001152 Above 200 Km. 37.00
Note :- Technical particulars as per Annexure A enclosed 4. TERMS OF DELIVERY : F. O. R Destination (Any where in C.G.State) 5. EXCISE DUTY : Not Applicable
6. SALES TAX /VAT : Extra, as Applicable TIN No. 22394300893 Address:-
M/s Bilaspur Cement Products, C/o Shri Sai Teles & Sanitary Main Road Tarwa Naka Bilaspur (C.G.) 495001 Mo.- 9425219302, 9893968974 Ph.-07752-410302
7. DELIVERY PERIOD : 45 Days 8. a. ANNUAL TURN OVER/ : NM b. MONETARY LIMIT : Not Mentioned c. INSTALLED CAPACITY : (as per Bilaspur DTIC Registration Certificate) Description Capacity/Annum
RCC HUME PIPE 15,000 Nos. 9. SLAB DISCOUNT (IF ANY) : Not Mentioned. 10. PRICES : Prices are Firm and Final. 11. MINIMUM QUANTITY IN : Not Mentioned. SINGLE SUPPLY ORDER
(Suresh Keshi) General Manager
![Page 95: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/95.jpg)
No. 95/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/BCP/6474 Dated: 31-03-2015 12. STATUS OF RC HOLDING : Manufacturer
FIRM
13. REGISTRATION STATUS : Manufacturer is Registered with Bilaspur DTIC DTIC EM Part- II 220071100886 Dated 05-06-2013
14 BIS LICENSE : Not Mentioned
15. PAYING AUTHORITY : As Mentioned in supply order to be issued by Direct Demanding Officers (DDOs).
16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each consignment there-of will be made after receipt and acceptance of the stores by the consignee/interim consignee in full and good condition within 20 days as per SPR rule No.11, if the bills are in order. In case of delay in payment without any reason the department will be liable to pay interest as per prevailing bank rate. Bills are to be submitted in the prescribed form of the paying authority of purchaser / indenter and are to be supported with inspection note issued by the inspector and consignee’s Receipt Certificate .
17 INSPECTION AUTHORITY : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah) OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
18 QUALITY ASSURANCE : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah) OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
(Suresh Keshi)
General Manager
![Page 96: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/96.jpg)
No. 96/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/BCP/6474 Dated: 31-03-2015
19. PLACE WHERE THE STORES Manufacturer’s Factory at
ARE TO BE OFFERED FOR M/s Bilaspur Cement Products, INSPECTION C/o Shri Sai Teles & Sanitary Main Road
Tarwa Naka Bilaspur (C.G.) 495001 Mo.- 9425219302, 9893968974 Ph.-07752-410302
20 INSPECTION CHARGES : 0.60% Inspection charges + Service Tax As Applicable to be paid extra at the time of inspection to Quality Assurance Officer which will be billed by the unit along with bill of the material and will be reimbursed by the paying authority of DDO.
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause 7, the Purchaser / DDOs may require the contractor to furnish a security deposit which shall be made after issue of the acceptance of the supply order within the period specified by the purchaser / DDOs. Such security deposit shall not ordinarily exceed 3% . The security shall be in form of Demand Drafts issued by any of the Scheduled Commercial Banks. No other form of security is to be accepted. The security deposit amount is to be refunded after successful completion of the supply.
22. Special Note : 1. Purchasing Departments / end user will ensure to sending the copy of every order to this office for Approval of inspection Agency against inspection of stores.
2. Purchasing Departments / end user will ensure to Pre Dispatch inspection of stores Through inspection agency in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to obtained the central excise invoices of Manufacturer as mentioned in the Schedule-A vide sr. no. 1-B if excise duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to execute the Integrity Pact between BUYER and BIDDER/SUPPLIEY in accordance with the letter vide no. 799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi) General Manager
![Page 97: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/97.jpg)
No. 97/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/BCP/6474 Dated: 31-03-2015
Annexure 'A' CSIDC/MKD/TECH/2014-15/14
TECHNICAL PARTICULARS OF R.C.C. HUME PIPES
TSC 15-10-2014
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes (Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish / Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket & Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
The Pipes shall be of the following Sizes & Classification: Schedule- 1: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for collar joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment
Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment. 2. Tenderers may also quote rates separately for the Collars. Dimensions and Design requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003, with up-to-date amendment. Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 98: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/98.jpg)
No. 98/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/BCP/6474 Dated: 31-03-2015 Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment 2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment. Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
8. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 99: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/99.jpg)
No. 99/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/BCP/6474 Dated: 31-03-2015 Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter in mm) , is as per below: 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule - 8 Transportation Charges:
Sub Item Code No.
Item Description Distance in km. Transportation Charges in % on the Total Cost of Pipes/ Collars
1 Upto 50 km. 2 Above 50 km. upto 100 km. 3 Above 100 km. upto 150 km. 4 Above 150 km. upto 200 km. 5 Above 200 km.
Inspection & Testing: As per prevailing practice, the following Review of Reports shall be carried out. Review of Reports: The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review: During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively, if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the Inspecting Officer for review.
(K.N.K. Mishra) Incharge PS-VII
![Page 100: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/100.jpg)
No. 100/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/BCP/6474 Dated: 31-03-2015 1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes. 2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement. 3. Manufacture’s Test Repot of Rubber Rings shall be submitted for review (incase of Pipes with Socket & Spigot ends). TESTS: As per prevailing practice, the following Tests / Checking shall be carried out. 1. Visual examination, 2. Permeability Test and 3. Three Edge Bearing Test to produce 0.25 mm crack. 4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date amendment shall be carried out if desired by the Consignee. NOTE: 1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. The length in which the pipes are to be supplied shall be as per the mutual agreement between the purchaser and the supplier. However, the recommended length above 300 mm Nominal Diameter is 2.5 meters. 4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. 6. The following information shall be shall be clearly marked on the each Finished Pipe. a. Size of Pipe, b. Class of Pipe, and c. Name of manufacture. 7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of receipt of the materials by the consignee. 8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment towards the supply of Rubber rings will be made) as per the prevailing practice, transportation cost for Pipes & Collars shall be quoted separately.
Recommended by Technical Specification Committee Dated 15-10-2014
(K.N.K. Mishra) Incharge PS-VII
![Page 101: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/101.jpg)
No. 101/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/BCP/6474 Dated: 31-03-2015
SCHEDULE ‘B’ (SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi) General Manager
![Page 102: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/102.jpg)
No. 102/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/BCP/6474 Dated: 31-03-2015
SCHEDULE – “D”
FORMAT FOR QUATERLY DRAWAL REPORT
Name of the Firm __________________ I- Jan-Mar Report No. __________________ II- Apr-June Rate Contract No. __________________ III- July-Sept. Date of Submission __________________ IV- Oct - Dec Total Position of Order against Rate Contract till the submission of Report. S.No. Name of
Department Quantity and Value of Orders Received (Rs.)
Quantity and Value of Orders Executed (Rs.)
Balance Quantity and Value to be Supplied (Rs.)
Reasons
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all Taxes duties and incidental b) Value of orders supplied during the quarter-Rs. Charges
2. Nil report should also be Submitted.
(Suresh Keshi) General Manager
![Page 103: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/103.jpg)
No. 103/336 S Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking) First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.) EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt) CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004 Website: www.csidc.in, Email : [email protected], [email protected]
No./CSIDC/MKD/ PS-VII /14-15/ Raipur, Dated :
Registered A/D Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/VSS/6475 Dated: 31-03-2015 To,
M/s Vasudev Shamji Savaria, Bajirao Mehrapara Raigarh (C.G.) 496001 Ph.- 07762-220050 Mo.- 099267-42045 Email- [email protected]
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 31-03-2015 to 01-04-2016) Ref :- (I) This Office Tender Enquiry No. PS-VII/CSIDC/MKD/102/510/14-15
(II) Bid No. 8429 Dated 18-11-2014 (III) Your Offer acceptance alongwith undertaking submitted on dated 25-03-2015
Dear Sir, You are hereby informed that your above referred tender read with subsequent letters mentioned above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction. You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the time of getting the payment. SCHEDULES ANNEXED: 1. Schedule “A” Description of Stores, Prices, Duties/Taxes . 2. Annexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions of contract (if any). 4. Schedule “C” Information to DDOs about parallel rate contracts. 5. Schedule “D” Format for Drawal Report. Encl. 13 pages
Yours faithfully,
(Suresh Keshi) General Manager
For and on behalf of the purchaser Named in CSIDC Form No.2
![Page 104: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/104.jpg)
No. 104/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/VSS/6475 Dated: 31-03-2015 Copy to, 1. The Secretary, Chhattisgarh Vidhan Sabha ,Raipur .
2. The Registrar, Honourable High court Chhattisgarh, Bilaspur .
3. The Accountant General Chhattisgarh State, Raipur.
4. All HODs of Chhattisgarh Govt. with a request to circulate the copy of R/C to all Direct Demanding Officers of your institution against issue of purchase order (Indent) in Favour of Rate Contract Holders of CSIDC.
5. All Collectors, Chhattisgarh State against issue of purchase order (Indent) in Favour of Rate Contract holders of CSIDC.
6. The Director Treasury, Chhattisgarh Govt., Raipur with a request to circulate copy of R/C to all branches under your control .
7. (i) Director of Public Instruction Department Pension Bada Raipur (ii) Engineer in Chief PHED C.G. Neer Bhawan, Raipur (iii) The Commissioner , Local Administrator , RDA Building Raipur (iv) Engineer in Chief PWD C.G.Civil lines Raipur .
Sr. No. 1 to 7 above are requested to call for original INK-SIGNED Rate Contract for verification to their full satisfaction including validity of various documents like Registration, Tax Registration etc. before taking action i.e. against issue of purchase order in Favour of Rate Contract holders of CSIDC, pre dispatched inspection of stores, acceptance of store.
8. (i) Dy.Director (Q.A.) , DGS&D, Bhilai, Durg (C.G.). (ii) Manager (Operation) Indian Register of Shipping, Senior MIG-2, Secter A, 1st Floor,
Infront of Bank of India Indrapuri Bhopal. (iii) Chief Engineer, PDIL, 4th floor, 4/2 Karaya Road, 67 Shekespeare Sarani, Kolkata (W.B.) (iv) General Manager (Inspection) RITES Ltd., Church gate Station Road, Second Floor, M.K.
Road, Mumbai-400020 (v) Operations Manager SGS India Pvt, Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal (MP)-
462011. above (i) to (v) are requested to call for original INK-SIGNED Rate Contract For Verification to their full satisfaction including validity of various documents like Validity of Registration, BIS Registration etc. before taking action i.e. inspection of stores, as the responsibility rests with the concerned authority. For information and necessary action against Authorized Inspection Agency accorded by CSIDC for inspection of stores.
9. Incharge, Monitoring Cell, MKT-1 CSIDC, Ltd. Raipur for necessary action against inspection of stores . 10. Manager (Tender), Marketing Div., CSIDC Ltd., Raipur. He is requested to maintain a master file
of Rate Contract. 11. Computer cell, CSIDC Ltd., Raipur to release Rate Contract on CSIDC website.
12. Main file of Item- RCC HUME PIPE
(Suresh Keshi) General Manager
![Page 105: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/105.jpg)
No. 105/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/VSS/6475 Dated: 31-03-2015
SCHEDULE “A” Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per Annexure’A’ enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Vasudev Shamji Savaria Bajirao, THE FIRM Mehrapara Raigarh (C.G.) 496001
Ph.- 07762-220050 Mo.- 099267-42045 Email- [email protected]
(b) NAME AND FULL ADDRESS OF :- M/s Vasudev Shamji Savaria Bajirao,
MANUFACTURER Mehrapara Raigarh (C.G.) 496001 Ph.- 07762-220050 Mo.- 099267-42045 Email- [email protected]
(C) Category :- General 2. VALIDITY OF RATE CONTRACT :- From 31-03-2015 To 01-04-2016 11. DESCRIPTION OF ITEM- RCC HUME PIPE SPECIFICATION, UNIT RATE AS BELOW
S.No. Item Code No. Item Description Class Rate ( )
E.D. VAT/CST Extra As Applicable
Rate Per Meter
Schedule -3: Reinforced Concrete, Medium duty, Non-Pressure Pipes, Class: NP3, with ends of the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
1 RCCHPF80001052 450 1050.00 2 RCCHPF80001053 500 1155.00 3 RCCHPF80001054 600 1480.50 4 RCCHPF80001055 700 1680.00 5 RCCHPF80001057 900 2936.38 6 RCCHPF80001058 1000 3052.39 7 RCCHPF80001060 1200 4378.50
Schedule -5: Reinforced Concrete, Heavy duty, Non-Pressure Pipes, Class: NP4, with ends of the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
8 RCCHPF80001096 600 1386.00 9 RCCHPF80001097 700 1732.50 10 RCCHPF80001099 900 2772.00 11 RCCHPF80001100 1000 3291.75 12 RCCHPF80001102 1200 4389.00
Schedule - 7 Transportation Charges : Sub Item Code No. Item Description Distance in Km. Transportation Charges in % on the Total Cost of Pipes/Collars.
E.D. VAT/CST Extra 13 RCCHPF80001148 Upto 50 Km. 19.64 14 RCCHPF80001149 Above 50 Km. Upto 100 Km. 21.00 15 RCCHPF80001150 Above 100 Km. Upto 150 Km. 28.88 16 RCCHPF80001151 Above 150 Km. Upto 200 Km. 32.00 17 RCCHPF80001152 Above 200 Km. 37.00
(Suresh Keshi)
General Manager
![Page 106: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/106.jpg)
No. 106/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/VSS/6475 Dated: 31-03-2015 Note :- Technical particulars as per Annexure A enclosed 4. TERMS OF DELIVERY : F. O. R Destination (Any where in C.G.State) 5. EXCISE DUTY : Not Applicable 6. SALES TAX /VAT : Extra, as Applicable
TIN No. 22184901293 Address:-
M/s Vasudev Shamji Savaria Bajirao, Mehrapara Raigarh (C.G.) 496001 Ph.- 07762-220050 Mo.- 099267-42045 Email- [email protected]
7. DELIVERY PERIOD : 21 Days 8. a. ANNUAL TURN OVER/ : 2011-12 Rs. 3030300.00
2012-13 Rs. 4023700.00 2013-14 Rs. 5221400.00
b. MONETARY LIMIT : Not Mentioned c. INSTALLED CAPACITY : (as per Raigarh DTIC Registration Certificate) Description Capacity/Annum
RCC HUME PIPE 42213 CFT.
9. SLAB DISCOUNT (IF ANY) : Not Mentioned. 10. PRICES : Prices are Firm and Final 11. MINIMUM QUANTITY IN : Not Mentioned. SINGLE SUPPLY ORDER 12. STATUS OF RC HOLDING : SSI Unit
FIRM 13. REGISTRATION STATUS : Manufacturer is Registered with Raigarh DTIC DTIC EM Part- II 220041100341 Dated 14-12-2010
14 BIS LICENSE : Not Mentioned
15. PAYING AUTHORITY : As Mentioned in supply order to be issued by Direct Demanding Officers (DDOs).
16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each consignment there-of will be made after receipt and acceptance of the stores by the consignee/interim consignee in full and good condition within 20 days as per SPR rule No.11, if the bills are in order. In case of delay in payment without any reason the department will be liable to pay interest as per prevailing bank rate. Bills are to be submitted in the prescribed form of the paying authority of purchaser / indenter and are to be supported with inspection note issued by the inspector and consignee’s Receipt Certificate .
(Suresh Keshi) General Manager
![Page 107: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/107.jpg)
No. 107/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/VSS/6475 Dated: 31-03-2015 17 INSPECTION AUTHORITY : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah) OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
18 QUALITY ASSURANCE : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah)
OR Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
19. PLACE WHERE THE STORES Manufacturer’s Factory at ARE TO BE OFFERED FOR M/s Vasudev Shamji Savaria Bajirao, INSPECTION Mehrapara Raigarh (C.G.) 496001
Ph.- 07762-220050 Mo.- 099267-42045 Email- [email protected]
20 INSPECTION CHARGES : 0.60% Inspection charges + Service Tax As Applicable to be paid extra at the time of inspection to Quality Assurance Officer which will be billed by the unit along with bill of the material and will be reimbursed by the paying authority of DDO.
(Suresh Keshi)
General Manager
![Page 108: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/108.jpg)
No. 108/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/VSS/6475 Dated: 31-03-2015
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause 7, the Purchaser / DDOs may require the contractor to furnish a security deposit which shall be made after issue of the acceptance of the supply order within the period specified by the purchaser / DDOs. Such security deposit shall not ordinarily exceed 3% . The security shall be in form of Demand Drafts issued by any of the Scheduled Commercial Banks. No other form of security is to be accepted. The security deposit amount is to be refunded after successful completion of the supply.
22. Special Note 1. Purchasing Departments / end user will ensure to sending the copy of every order to this office for Approval of inspection Agency against inspection of stores. 2. Purchasing Departments / end user will ensure to Pre
Dispatch inspection of stores Through inspection agency in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to obtained the central excise invoices of Manufacturer as mentioned in the Schedule-A vide sr. no. 1-B if excise duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to execute the Integrity Pact between BUYER and BIDDER/SUPPLIEY in accordance with the letter vide no. 799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi) General Manager
![Page 109: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/109.jpg)
No. 109/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/VSS/6475 Dated: 31-03-2015
Annexure 'A' CSIDC/MKD/TECH/2014-15/14
TECHNICAL PARTICULARS OF R.C.C. HUME PIPES
TSC 15-10-2014
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes (Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish / Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket & Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
The Pipes shall be of the following Sizes & Classification: Schedule- 1: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for collar joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment
Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment. 2. Tenderers may also quote rates separately for the Collars. Dimensions and Design requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003, with up-to-date amendment. Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 110: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/110.jpg)
No. 110/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/VSS/6475 Dated: 31-03-2015 Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment 2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment. Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
9. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 111: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/111.jpg)
No. 111/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/VSS/6475 Dated: 31-03-2015 Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter in mm) , is as per below: 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule - 8 Transportation Charges:
Sub Item Code No.
Item Description Distance in km. Transportation Charges in % on the Total Cost of Pipes/ Collars
1 Upto 50 km. 2 Above 50 km. upto 100 km. 3 Above 100 km. upto 150 km. 4 Above 150 km. upto 200 km. 5 Above 200 km.
Inspection & Testing: As per prevailing practice, the following Review of Reports shall be carried out. Review of Reports: The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review: During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively, if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the Inspecting Officer for review.
(K.N.K. Mishra) Incharge PS-VII
![Page 112: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/112.jpg)
No. 112/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/VSS/6475 Dated: 31-03-2015 1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes. 2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement. 3. Manufacture’s Test Repot of Rubber Rings shall be submitted for review (incase of Pipes with Socket & Spigot ends). TESTS: As per prevailing practice, the following Tests / Checking shall be carried out. 1. Visual examination, 2. Permeability Test and 3. Three Edge Bearing Test to produce 0.25 mm crack. 4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date amendment shall be carried out if desired by the Consignee. NOTE: 1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. The length in which the pipes are to be supplied shall be as per the mutual agreement between the purchaser and the supplier. However, the recommended length above 300 mm Nominal Diameter is 2.5 meters. 4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. 6. The following information shall be shall be clearly marked on the each Finished Pipe. a. Size of Pipe, b. Class of Pipe, and c. Name of manufacture. 7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of receipt of the materials by the consignee. 8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment towards the supply of Rubber rings will be made) as per the prevailing practice, transportation cost for Pipes & Collars shall be quoted separately.
Recommended by Technical Specification Committee Dated 15-10-2014
(K.N.K. Mishra) Incharge PS-VII
![Page 113: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/113.jpg)
No. 113/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/VSS/6475 Dated: 31-03-2015
SCHEDULE ‘B’ (SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi) General Manager
![Page 114: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/114.jpg)
No. 114/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/VSS/6475 Dated: 31-03-2015
SCHEDULE – “D”
FORMAT FOR QUATERLY DRAWAL REPORT
Name of the Firm __________________ I- Jan-Mar Report No. __________________ II- Apr-June Rate Contract No. __________________ III- July-Sept. Date of Submission __________________ IV- Oct - Dec Total Position of Order against Rate Contract till the submission of Report. S.No. Name of
Department Quantity and Value of Orders Received (Rs.)
Quantity and Value of Orders Executed (Rs.)
Balance Quantity and Value to be Supplied (Rs.)
Reasons
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all Taxes duties and incidental b) Value of orders supplied during the quarter-Rs. Charges
2. Nil report should also be Submitted.
(Suresh Keshi) General Manager
![Page 115: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/115.jpg)
No. 115/336 Chhattisgarh State Industrial Development Corporation Limited (A Government of Chhattisgarh Undertaking) First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.) EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt) CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004 Website: www.csidc.in, Email : [email protected], [email protected]
No./CSIDC/MKD/ PS-VII /14-15/ Raipur, Dated :
Registered A/D Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/DI/6476 Dated: 31-03-2015 To,
M/s Dinesh Industries, Telibandha, Near Gali No.- 6 Ravigram,
Ph.- 0771-3265888 Mo.- 9755042331, 9926156001 Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 31-03-2015 to 01-04-2016) Ref :- (I) This Office Tender Enquiry No. PS-VII/CSIDC/MKD/102/510/14-15
(II) Bid No. 8425 Dated 18-11-2014 (III) Your Offer acceptance alongwith undertaking submitted on dated 26-03-2015
Dear Sir, You are hereby informed that your above referred tender read with subsequent letters mentioned above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction. You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the time of getting the payment. SCHEDULES ANNEXED: 1. Schedule “A” Description of Stores, Prices, Duties/Taxes . 2. Annexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions of contract (if any). 4. Schedule “C” Information to DDOs about parallel rate contracts. 5. Schedule “D” Format for Drawal Report. Encl. 13 pages
Yours faithfully,
(Suresh Keshi) General Manager
For and on behalf of the purchaser Named in CSIDC Form No.2
![Page 116: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/116.jpg)
No. 116/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/DI/6476 Dated: 31-03-2015 Copy to, 1. The Secretary, Chhattisgarh Vidhan Sabha ,Raipur .
2. The Registrar, Honourable High court Chhattisgarh, Bilaspur .
3. The Accountant General Chhattisgarh State, Raipur.
4. All HODs of Chhattisgarh Govt. with a request to circulate the copy of R/C to all Direct Demanding Officers of your institution against issue of purchase order (Indent) in Favour of Rate Contract Holders of CSIDC.
5. All Collectors, Chhattisgarh State against issue of purchase order (Indent) in Favour of Rate Contract holders of CSIDC.
6. The Director Treasury, Chhattisgarh Govt., Raipur with a request to circulate copy of R/C to all branches under your control .
7. (i) Director of Public Instruction Department Pension Bada Raipur (ii) Engineer in Chief PHED C.G. Neer Bhawan, Raipur (iii) The Commissioner , Local Administrator , RDA Building Raipur (iv) Engineer in Chief PWD C.G.Civil lines Raipur .
Sr. No. 1 to 7 above are requested to call for original INK-SIGNED Rate Contract for verification to their full satisfaction including validity of various documents like Registration, Tax Registration etc. before taking action i.e. against issue of purchase order in Favour of Rate Contract holders of CSIDC, pre dispatched inspection of stores, acceptance of store.
8. (i) Dy.Director (Q.A.) , DGS&D, Bhilai, Durg (C.G.). (ii) Manager (Operation) Indian Register of Shipping, Senior MIG-2, Secter A, 1st Floor,
Infront of Bank of India Indrapuri Bhopal. (iii) Chief Engineer, PDIL, 4th floor, 4/2 Karaya Road, 67 Shekespeare Sarani, Kolkata (W.B.) (iv) General Manager (Inspection) RITES Ltd., Church gate Station Road, Second Floor, M.K.
Road, Mumbai-400020 (v) Operations Manager SGS India Pvt, Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal (MP)-
462011. above (i) to (v) are requested to call for original INK-SIGNED Rate Contract For Verification to their full satisfaction including validity of various documents like Validity of Registration, BIS Registration etc. before taking action i.e. inspection of stores, as the responsibility rests with the concerned authority. For information and necessary action against Authorized Inspection Agency accorded by CSIDC for inspection of stores.
9. Incharge, Monitoring Cell, MKT-1 CSIDC, Ltd. Raipur for necessary action against inspection of stores . 10. Manager (Tender), Marketing Div., CSIDC Ltd., Raipur. He is requested to maintain a master file
of Rate Contract. 11. Computer cell, CSIDC Ltd., Raipur to release Rate Contract on CSIDC website.
12. Main file of Item- RCC HUME PIPE
(Suresh Keshi) General Manager
![Page 117: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/117.jpg)
No. 117/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/DI/6476 Dated: 31-03-2015
SCHEDULE “A” Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per Annexure’A’ enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Dinesh Industries, THE FIRM Telibandha, Near Gali No.- 6 Ravigram,
Ph.- 0771-3265888 Mo.- 9755042331, 9926156001 (b) NAME AND FULL ADDRESS OF :- M/s Dinesh Industries,
MANUFACTURER Plot No. 730 A Industrial Estate Urla Raipur (C.G.) 492001 Ph.- 0771-3265888
Mo.- 9755042331, 9926156001 (C) Category :- General 2. VALIDITY OF RATE CONTRACT :- From 31-03-2015 To 01-04-2016 12. DESCRIPTION OF ITEM- RCC HUME PIPE SPECIFICATION, UNIT RATE AS BELOW
S.No. Item Code No. Item Description Class Rate ( )
E.D. VAT/CST Extra As Applicable
Rate Per Meter
Schedule -3: Reinforced Concrete, Medium duty, Non-Pressure Pipes, Class: NP3, with ends of the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
1 RCCHPF80001052 450 1050.00 2 RCCHPF80001053 500 1155.00 3 RCCHPF80001054 600 1480.50 4 RCCHPF80001057 900 2936.38 5 RCCHPF80001058 1000 3052.39 6 RCCHPF80001060 1200 4378.50 7 RCCHPF80001061 1400 5911.43
Schedule -5: Reinforced Concrete, Heavy duty, Non-Pressure Pipes, Class: NP4, with ends of the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
8 RCCHPF80001095 500 1239.91 Schedule - 7 Transportation Charges : Sub Item Code No. Item Description Distance in Km. Transportation Charges in % on the Total Cost of Pipes/Collars.
E.D. VAT/CST Extra 9 RCCHPF80001148 Upto 50 Km. 19.64
10 RCCHPF80001149 Above 50 Km. Upto 100 Km. 21.00 11 RCCHPF80001150 Above 100 Km. Upto 150 Km. 28.88 12 RCCHPF80001151 Above 150 Km. Upto 200 Km. 32.00 13 RCCHPF80001152 Above 200 Km. 37.00
Note :- Technical particulars as per Annexure A enclosed
(Suresh Keshi) General Manager
![Page 118: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/118.jpg)
No. 118/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/DI/6476 Dated: 31-03-2015 4. TERMS OF DELIVERY : F. O. R Destination (Any where in C.G.State) 5. EXCISE DUTY : Not Applicable 6. SALES TAX /VAT : Extra, as Applicable
TIN No. 22141900620 Address:-
M/s Dinesh Industries, Telibandha, Near Gali No.- 6 Ravigram,
Ph.- 0771-3265888 Mo.- 9755042331, 9926156001 7. DELIVERY PERIOD : 45 Days 8. a. ANNUAL TURN OVER/ : NM b. MONETARY LIMIT : Not Mentioned c. INSTALLED CAPACITY : (as per Raipur DTIC Registration Certificate) Description Capacity/Annum
1 RCC Hume Pipes
180000 CU.FT.
2 Water Tanks 3 Septic Tanks 4 Dust Bins 5 Fencing Poles 6 Precast Cocrete Slabs 7 Kilometre Stone & Boundary Stone
9. SLAB DISCOUNT (IF ANY) : Not Mentioned. 10. PRICES : Prices are Firm and Final 11. MINIMUM QUANTITY IN : Not Mentioned. SINGLE SUPPLY ORDER 12. STATUS OF RC HOLDING : Manufacturer
FIRM
13. REGISTRATION STATUS : Manufacturer is Registered with Raipur DTIC DTIC EM Part- II 220111102154 Dated 18-11-2014
14 BIS LICENSE : Not Mentioned 15. PAYING AUTHORITY : As Mentioned in supply order to be issued by Direct Demanding
Officers (DDOs).
(Suresh Keshi) General Manager
![Page 119: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/119.jpg)
No. 119/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/DI/6476 Dated: 31-03-2015
16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each
consignment there-of will be made after receipt and acceptance of the stores by the consignee/interim consignee in full and good condition within 20 days as per SPR rule No.11, if the bills are in order. In case of delay in payment without any reason the department will be liable to pay interest as per prevailing bank rate. Bills are to be submitted in the prescribed form of the paying authority of purchaser / indenter and are to be supported with inspection note issued by the inspector and consignee’s Receipt Certificate .
17 INSPECTION AUTHORITY : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah) OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
18 QUALITY ASSURANCE : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah) OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
19. PLACE WHERE THE STORES Manufacturer’s Factory at
ARE TO BE OFFERED FOR M/s Dinesh Industries, INSPECTION Telibandha, Near Gali No.- 6 Ravigram,
Raipur Factory 730 A Industrial Estate Urla Raipur (C.G.) 492001 Ph.- 0771-3265888
Mo.- 9755042331, 9926156001
(Suresh Keshi) General Manager
![Page 120: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/120.jpg)
No. 120/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/DI/6476 Dated: 31-03-2015 20 INSPECTION CHARGES : 0.60% Inspection charges + Service Tax As Applicable to be
paid extra at the time of inspection to Quality Assurance Officer which will be billed by the unit along with bill of the material and will be reimbursed by the paying authority of DDO.
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause 7, the Purchaser / DDOs may require the contractor to furnish a security deposit which shall be made after issue of the acceptance of the supply order within the period specified by the purchaser / DDOs. Such security deposit shall not ordinarily exceed 3% . The security shall be in form of Demand Drafts issued by any of the Scheduled Commercial Banks. No other form of security is to be accepted. The security deposit amount is to be refunded after successful completion of the supply.
22. Special Note 1. Purchasing Departments / end user will ensure to sending the copy of every order to this office for Approval of inspection Agency against inspection of stores. 2. Purchasing Departments / end user will ensure to Pre
Dispatch inspection of stores Through inspection agency in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to obtained the central excise invoices of Manufacturer as mentioned in the Schedule-A vide sr. no. 1-B if excise duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to execute the Integrity Pact between BUYER and BIDDER/SUPPLIEY in accordance with the letter vide no. 799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi) General Manager
![Page 121: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/121.jpg)
No. 121/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/DI/6476 Dated: 31-03-2015
Annexure 'A' CSIDC/MKD/TECH/2014-15/14
TECHNICAL PARTICULARS OF R.C.C. HUME PIPES
TSC 15-10-2014
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes (Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish / Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket & Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
The Pipes shall be of the following Sizes & Classification: Schedule- 1: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for collar joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment
Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment. 2. Tenderers may also quote rates separately for the Collars. Dimensions and Design requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003, with up-to-date amendment. Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 122: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/122.jpg)
No. 122/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/DI/6476 Dated: 31-03-2015 Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment 2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment. Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
10. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 123: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/123.jpg)
No. 123/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/DI/6476 Dated: 31-03-2015 Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter in mm) , is as per below: 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule - 8 Transportation Charges:
Sub Item Code No.
Item Description Distance in km. Transportation Charges in % on the Total Cost of Pipes/ Collars
1 Upto 50 km. 2 Above 50 km. upto 100 km. 3 Above 100 km. upto 150 km. 4 Above 150 km. upto 200 km. 5 Above 200 km.
Inspection & Testing: As per prevailing practice, the following Review of Reports shall be carried out. Review of Reports: The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review: During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively, if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the Inspecting Officer for review.
(K.N.K. Mishra) Incharge PS-VII
![Page 124: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/124.jpg)
No. 124/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/DI/6476 Dated: 31-03-2015 1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes. 2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement. 3. Manufacture’s Test Repot of Rubber Rings shall be submitted for review (incase of Pipes with Socket & Spigot ends). TESTS: As per prevailing practice, the following Tests / Checking shall be carried out. 1. Visual examination, 2. Permeability Test and 3. Three Edge Bearing Test to produce 0.25 mm crack. 4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date amendment shall be carried out if desired by the Consignee. NOTE: 1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. The length in which the pipes are to be supplied shall be as per the mutual agreement between the purchaser and the supplier. However, the recommended length above 300 mm Nominal Diameter is 2.5 meters. 4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. 6. The following information shall be shall be clearly marked on the each Finished Pipe. a. Size of Pipe, b. Class of Pipe, and c. Name of manufacture. 7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of receipt of the materials by the consignee. 8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment towards the supply of Rubber rings will be made) as per the prevailing practice, transportation cost for Pipes & Collars shall be quoted separately.
Recommended by Technical Specification Committee Dated 15-10-2014
(K.N.K. Mishra) Incharge PS-VII
![Page 125: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/125.jpg)
No. 125/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/DI/6476 Dated: 31-03-2015
SCHEDULE ‘B’ (SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi) General Manager
![Page 126: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/126.jpg)
No. 126/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/DI/6476 Dated: 31-03-2015
SCHEDULE – “D”
FORMAT FOR QUATERLY DRAWAL REPORT
Name of the Firm __________________ I- Jan-Mar Report No. __________________ II- Apr-June Rate Contract No. __________________ III- July-Sept. Date of Submission __________________ IV- Oct - Dec Total Position of Order against Rate Contract till the submission of Report. S.No. Name of
Department Quantity and Value of Orders Received (Rs.)
Quantity and Value of Orders Executed (Rs.)
Balance Quantity and Value to be Supplied (Rs.)
Reasons
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all Taxes duties and incidental b) Value of orders supplied during the quarter-Rs. Charges
2. Nil report should also be Submitted.
(Suresh Keshi) General Manager
![Page 127: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/127.jpg)
No. 127/336 S Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking) First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.) EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt) CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004 Website: www.csidc.in, Email : [email protected], [email protected]
No./CSIDC/MKD/ PS-VII /14-15/ Raipur, Dated :
Registered A/D Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/QCP/6477 Dated: 31-03-2015 To,
M/s Quality Cement Pipes, Add : 11,12 Industrial Estate Bhanpuri Raipur (C.G.) 493221 Ph.- 0771-4024190 Mo.- 9752005557
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 31-03-2015 to 01-04-2016) Ref :- (I) This Office Tender Enquiry No. PS-VII/CSIDC/MKD/102/510/14-15
(II) Bid No. 8390 Dated 29-10-2014 (III) Your Offer acceptance alongwith undertaking submitted on dated 26-03-2015
Dear Sir, You are hereby informed that your above referred tender read with subsequent letters mentioned above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction. You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the time of getting the payment. SCHEDULES ANNEXED: 1. Schedule “A” Description of Stores, Prices, Duties/Taxes . 2. Annexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions of contract (if any). 4. Schedule “C” Information to DDOs about parallel rate contracts. 5. Schedule “D” Format for Drawal Report. Encl. 13 pages
Yours faithfully,
(Suresh Keshi) General Manager
For and on behalf of the purchaser Named in CSIDC Form No.2
![Page 128: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/128.jpg)
No. 128/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/QCP/6477 Dated: 31-03-2015 Copy to, 1. The Secretary, Chhattisgarh Vidhan Sabha ,Raipur .
2. The Registrar, Honourable High court Chhattisgarh, Bilaspur .
3. The Accountant General Chhattisgarh State, Raipur.
4. All HODs of Chhattisgarh Govt. with a request to circulate the copy of R/C to all Direct Demanding Officers of your institution against issue of purchase order (Indent) in Favour of Rate Contract Holders of CSIDC.
5. All Collectors, Chhattisgarh State against issue of purchase order (Indent) in Favour of Rate Contract holders of CSIDC.
6. The Director Treasury, Chhattisgarh Govt., Raipur with a request to circulate copy of R/C to all branches under your control .
7. (i) Director of Public Instruction Department Pension Bada Raipur (ii) Engineer in Chief PHED C.G. Neer Bhawan, Raipur (iii) The Commissioner , Local Administrator , RDA Building Raipur (iv) Engineer in Chief PWD C.G.Civil lines Raipur .
Sr. No. 1 to 7 above are requested to call for original INK-SIGNED Rate Contract for verification to their full satisfaction including validity of various documents like Registration, Tax Registration etc. before taking action i.e. against issue of purchase order in Favour of Rate Contract holders of CSIDC, pre dispatched inspection of stores, acceptance of store.
8. (i) Dy.Director (Q.A.) , DGS&D, Bhilai, Durg (C.G.). (ii) Manager (Operation) Indian Register of Shipping, Senior MIG-2, Secter A, 1st Floor,
Infront of Bank of India Indrapuri Bhopal. (iii) Chief Engineer, PDIL, 4th floor, 4/2 Karaya Road, 67 Shekespeare Sarani, Kolkata (W.B.) (iv) General Manager (Inspection) RITES Ltd., Church gate Station Road, Second Floor, M.K.
Road, Mumbai-400020 (v) Operations Manager SGS India Pvt, Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal (MP)-
462011. above (i) to (v) are requested to call for original INK-SIGNED Rate Contract For Verification to their full satisfaction including validity of various documents like Validity of Registration, BIS Registration etc. before taking action i.e. inspection of stores, as the responsibility rests with the concerned authority. For information and necessary action against Authorized Inspection Agency accorded by CSIDC for inspection of stores.
9. Incharge, Monitoring Cell, MKT-1 CSIDC, Ltd. Raipur for necessary action against inspection of stores . 10. Manager (Tender), Marketing Div., CSIDC Ltd., Raipur. He is requested to maintain a master file
of Rate Contract. 11. Computer cell, CSIDC Ltd., Raipur to release Rate Contract on CSIDC website.
12. Main file of Item- RCC HUME PIPE
(Suresh Keshi) General Manager
![Page 129: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/129.jpg)
No. 129/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/QCP/6477 Dated: 31-03-2015
SCHEDULE “A” Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per Annexure’A’ enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Quality Cement Pipes, THE FIRM Add : 11,12 Industrial Estate
Bhanpuri Raipur (C.G.) 493221 Ph.-0771-4024190 Mo.- 9752005557
(b) NAME AND FULL ADDRESS OF :- M/s Quality Cement Pipes,
MANUFACTURER Add : 11,12 Industrial Estate Bhanpuri Raipur (C.G.) 493221 Ph.-0771-4024190 Mo.- 9752005557
(C) Category :- General 2. VALIDITY OF RATE CONTRACT :- From 31-03-2015 To 01-04-2016 13. DESCRIPTION OF ITEM- RCC HUME PIPE SPECIFICATION, UNIT RATE AS BELOW
S.No. Item Code No. Item Description Class Rate ( )
E.D. VAT/CST Extra As
Applicable Rate Per Meter
Schedule -3: Reinforced Concrete, Medium duty, Non-Pressure Pipes, Class: NP3, with ends of the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
1 RCCHPF80001052 450 1050.00 2 RCCHPF80001053 500 1155.00 3 RCCHPF80001054 600 1480.50 4 RCCHPF80001057 900 2936.38 5 RCCHPF80001058 1000 3052.39 6 RCCHPF80001060 1200 4378.50 7 RCCHPF80001061 1400 5911.43
Schedule -5: Reinforced Concrete, Heavy duty, Non-Pressure Pipes, Class: NP4, with ends of the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
8 RCCHPF80001088 200 302.61 9 RCCHPF80001089 225 324.32
10 RCCHPF80001090 250 374.22 11 RCCHPF80001095 500 1239.91
Schedule - 7 Transportation Charges : Sub Item Code No. Item Description Distance in Km. Transportation Charges in % on the Total Cost of Pipes/Collars.
E.D. VAT/CST Extra 12 RCCHPF80001148 Upto 50 Km. 19.64 13 RCCHPF80001149 Above 50 Km. Upto 100 Km. 21.00 14 RCCHPF80001150 Above 100 Km. Upto 150 Km. 28.88 15 RCCHPF80001151 Above 150 Km. Upto 200 Km. 32.00 16 RCCHPF80001152 Above 200 Km. 37.00
(Suresh Keshi) General Manager
![Page 130: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/130.jpg)
No. 130/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/QCP/6477 Dated: 31-03-2015 Note :- Technical particulars as per Annexure A enclosed 4. TERMS OF DELIVERY : F. O. R Destination (Any where in C.G.State) 5. EXCISE DUTY : Not Applicable 6. SALES TAX /VAT : Extra, as Applicable
TIN No. 22511301296 Address:-
M/s Quality Cement Pipes, Add : 11,12 Industrial Estate Bhanpuri Raipur (C.G.) 493221 Ph.-0771-4024190 Mo.- 9752005557
7. DELIVERY PERIOD : 45 Days 8. a. ANNUAL TURN OVER/ : 2010-11 Rs. 10876306.25
2011-12 Rs. 11954369.00 2012-13 Rs. 11492873.75
b. MONETARY LIMIT : Not Mentioned c. INSTALLED CAPACITY : (as per Raipur DTIC Registration Certificate) Description Capacity/Annum
1 R.C.C. Hume Pipe
80,000 CFT. 2 R.C.C. Fencing Pole 3 R.C.C. Kilometer Stone 4 R.C.C. Boundary Stone 5 R.C.C. Water Septic Tank
9. SLAB DISCOUNT (IF ANY) : Not Mentioned. 10. PRICES : Prices are Firm and Final. 11. MINIMUM QUANTITY IN : Not Mentioned. SINGLE SUPPLY ORDER 12. STATUS OF RC HOLDING : Manufacturer
FIRM
13. REGISTRATION STATUS : Manufacturer is Registered with Durg Raipur DTIC EM Part- II 220111100941 16-07-2009
14 BIS LICENSE : Not Mentioned
15. PAYING AUTHORITY : As Mentioned in supply order to be issued by Direct Demanding Officers (DDOs).
(Suresh Keshi) General Manager
![Page 131: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/131.jpg)
No. 131/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/QCP/6477 Dated: 31-03-2015
16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each
consignment there-of will be made after receipt and acceptance of the stores by the consignee/interim consignee in full and good condition within 20 days as per SPR rule No.11, if the bills are in order. In case of delay in payment without any reason the department will be liable to pay interest as per prevailing bank rate. Bills are to be submitted in the prescribed form of the paying authority of purchaser / indenter and are to be supported with inspection note issued by the inspector and consignee’s Receipt Certificate .
17 INSPECTION AUTHORITY : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah) OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
18 QUALITY ASSURANCE : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah) OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
19. PLACE WHERE THE STORES Manufacturer’s Factory at
ARE TO BE OFFERED FOR M/s Quality Cement Pipes, INSPECTION Add : 11,12 Industrial Estate
Bhanpuri Raipur (C.G.) 493221 Ph.-0771-4024190 Mo.- 9752005557
(Suresh Keshi) General Manager
![Page 132: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/132.jpg)
No. 132/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/QCP/6477 Dated: 31-03-2015
20 INSPECTION CHARGES : 0.60% Inspection charges + Service Tax As Applicable to be paid extra at the time of inspection to Quality Assurance Officer which will be billed by the unit along with bill of the material and will be reimbursed by the paying authority of DDO.
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause 7, the Purchaser / DDOs may require the contractor to furnish a security deposit which shall be made after issue of the acceptance of the supply order within the period specified by the purchaser / DDOs. Such security deposit shall not ordinarily exceed 3% . The security shall be in form of Demand Drafts issued by any of the Scheduled Commercial Banks. No other form of security is to be accepted. The security deposit amount is to be refunded after successful completion of the supply.
22. Special Note 1. Purchasing Departments / end user will ensure to sending the copy of every order to this office for Approval of inspection Agency against inspection of stores. 2. Purchasing Departments / end user will ensure to Pre
Dispatch inspection of stores Through inspection agency in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to obtained the central excise invoices of Manufacturer as mentioned in the Schedule-A vide sr. no. 1-B if excise duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to execute the Integrity Pact between BUYER and BIDDER/SUPPLIEY in accordance with the letter vide no. 799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi) General Manager
![Page 133: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/133.jpg)
No. 133/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/QCP/6477 Dated: 31-03-2015
Annexure 'A' CSIDC/MKD/TECH/2014-15/14
TECHNICAL PARTICULARS OF R.C.C. HUME PIPES
TSC 15-10-2014
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes (Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish / Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket & Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
The Pipes shall be of the following Sizes & Classification: Schedule- 1: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for collar joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment
Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment. 2. Tenderers may also quote rates separately for the Collars. Dimensions and Design requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003, with up-to-date amendment. Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 134: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/134.jpg)
No. 134/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/QCP/6477 Dated: 31-03-2015 Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment 2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment. Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
11. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 135: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/135.jpg)
No. 135/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/QCP/6477 Dated: 31-03-2015 Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter in mm) , is as per below: 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule - 8 Transportation Charges:
Sub Item Code No.
Item Description Distance in km. Transportation Charges in % on the Total Cost of Pipes/ Collars
1 Upto 50 km. 2 Above 50 km. upto 100 km. 3 Above 100 km. upto 150 km. 4 Above 150 km. upto 200 km. 5 Above 200 km.
Inspection & Testing: As per prevailing practice, the following Review of Reports shall be carried out. Review of Reports: The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review: During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively, if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the Inspecting Officer for review.
(K.N.K. Mishra) Incharge PS-VII
![Page 136: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/136.jpg)
No. 136/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/QCP/6477 Dated: 31-03-2015 1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes. 2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement. 3. Manufacture’s Test Repot of Rubber Rings shall be submitted for review (incase of Pipes with Socket & Spigot ends). TESTS: As per prevailing practice, the following Tests / Checking shall be carried out. 1. Visual examination, 2. Permeability Test and 3. Three Edge Bearing Test to produce 0.25 mm crack. 4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date amendment shall be carried out if desired by the Consignee. NOTE: 1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. The length in which the pipes are to be supplied shall be as per the mutual agreement between the purchaser and the supplier. However, the recommended length above 300 mm Nominal Diameter is 2.5 meters. 4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. 6. The following information shall be shall be clearly marked on the each Finished Pipe. a. Size of Pipe, b. Class of Pipe, and c. Name of manufacture. 7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of receipt of the materials by the consignee. 8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment towards the supply of Rubber rings will be made) as per the prevailing practice, transportation cost for Pipes & Collars shall be quoted separately.
Recommended by Technical Specification Committee Dated 15-10-2014
(K.N.K. Mishra) Incharge PS-VII
![Page 137: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/137.jpg)
No. 137/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/QCP/6477 Dated: 31-03-2015
SCHEDULE ‘B’ (SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi) General Manager
![Page 138: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/138.jpg)
No. 138/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/QCP/6477 Dated: 31-03-2015
SCHEDULE – “D”
FORMAT FOR QUATERLY DRAWAL REPORT
Name of the Firm __________________ I- Jan-Mar Report No. __________________ II- Apr-June Rate Contract No. __________________ III- July-Sept. Date of Submission __________________ IV- Oct - Dec Total Position of Order against Rate Contract till the submission of Report. S.No. Name of
Department Quantity and Value of Orders Received (Rs.)
Quantity and Value of Orders Executed (Rs.)
Balance Quantity and Value to be Supplied (Rs.)
Reasons
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all Taxes duties and incidental b) Value of orders supplied during the quarter-Rs. Charges
2. Nil report should also be Submitted.
(Suresh Keshi) General Manager
![Page 139: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/139.jpg)
No. 139/336 eS Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking) First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.) EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt) CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004 Website: www.csidc.in, Email : [email protected], [email protected]
No./CSIDC/MKD/ PS-VII /14-15/ Raipur, Dated :
Registered A/D Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RP/6478 Dated: 31-03-2015 To,
M/s Raj Pipes, Infront of Industrial Estate, G.E. Road, Rajnandgaon (C.G.)
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 31-03-2015 to 01-04-2016) Ref :- (I) This Office Tender Enquiry No. PS-VII/CSIDC/MKD/102/510/14-15
(II) Bid No. 8423 Dated 15-11-2014 (III) Your Offer acceptance alongwith undertaking submitted on dated 26-03-2015
Dear Sir, You are hereby informed that your above referred tender read with subsequent letters mentioned above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction. You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the time of getting the payment. SCHEDULES ANNEXED: 1. Schedule “A” Description of Stores, Prices, Duties/Taxes . 2. Annexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions of contract (if any). 4. Schedule “C” Information to DDOs about parallel rate contracts. 5. Schedule “D” Format for Drawal Report. Encl. 13 pages
Yours faithfully,
(Suresh Keshi) General Manager
For and on behalf of the purchaser Named in CSIDC Form No.2
![Page 140: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/140.jpg)
No. 140/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RP/6478 Dated: 31-03-2015 Copy to, 1. The Secretary, Chhattisgarh Vidhan Sabha ,Raipur .
2. The Registrar, Honourable High court Chhattisgarh, Bilaspur .
3. The Accountant General Chhattisgarh State, Raipur.
4. All HODs of Chhattisgarh Govt. with a request to circulate the copy of R/C to all Direct Demanding Officers of your institution against issue of purchase order (Indent) in Favour of Rate Contract Holders of CSIDC.
5. All Collectors, Chhattisgarh State against issue of purchase order (Indent) in Favour of Rate Contract holders of CSIDC.
6. The Director Treasury, Chhattisgarh Govt., Raipur with a request to circulate copy of R/C to all branches under your control .
7. (i) Director of Public Instruction Department Pension Bada Raipur (ii) Engineer in Chief PHED C.G. Neer Bhawan, Raipur (iii) The Commissioner , Local Administrator , RDA Building Raipur (iv) Engineer in Chief PWD C.G.Civil lines Raipur .
Sr. No. 1 to 7 above are requested to call for original INK-SIGNED Rate Contract for verification to their full satisfaction including validity of various documents like Registration, Tax Registration etc. before taking action i.e. against issue of purchase order in Favour of Rate Contract holders of CSIDC, pre dispatched inspection of stores, acceptance of store.
8. (i) Dy.Director (Q.A.) , DGS&D, Bhilai, Durg (C.G.). (ii) Manager (Operation) Indian Register of Shipping, Senior MIG-2, Secter A, 1st Floor,
Infront of Bank of India Indrapuri Bhopal. (iii) Chief Engineer, PDIL, 4th floor, 4/2 Karaya Road, 67 Shekespeare Sarani, Kolkata (W.B.) (iv) General Manager (Inspection) RITES Ltd., Church gate Station Road, Second Floor, M.K.
Road, Mumbai-400020 (v) Operations Manager SGS India Pvt, Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal (MP)-
462011. above (i) to (v) are requested to call for original INK-SIGNED Rate Contract For Verification to their full satisfaction including validity of various documents like Validity of Registration, BIS Registration etc. before taking action i.e. inspection of stores, as the responsibility rests with the concerned authority. For information and necessary action against Authorized Inspection Agency accorded by CSIDC for inspection of stores.
9. Incharge, Monitoring Cell, MKT-1 CSIDC, Ltd. Raipur for necessary action against inspection of stores . 10. Manager (Tender), Marketing Div., CSIDC Ltd., Raipur. He is requested to maintain a master file
of Rate Contract. 11. Computer cell, CSIDC Ltd., Raipur to release Rate Contract on CSIDC website.
12. Main file of Item- RCC HUME PIPE
(Suresh Keshi) General Manager
![Page 141: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/141.jpg)
No. 141/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RP/6478 Dated: 31-03-2015
SCHEDULE “A” Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per Annexure’A’ enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Raj Pipes, THE FIRM Infront of Industrial Estate,
G.E. Road, Rajnandgaon (C.G.)
(b) NAME AND FULL ADDRESS OF :- M/s Raj Pipes, MANUFACTURER Infront of Industrial Estate,
G.E. Road, Rajnandgaon (C.G.)
(C) Category :- General 2. VALIDITY OF RATE CONTRACT :- From 31-03-2015 To 01-04-2016 14. DESCRIPTION OF ITEM- RCC HUME PIPE SPECIFICATION, UNIT RATE AS BELOW
S.No. Item Code No. Item Description Class Rate ( )
E.D. VAT/CST Extra As Applicable
Rate Per Meter
Schedule -1: Reinforced Concrete, Light duty, Non-Pressure Pipes, Class: NP2, with ends of the Pipes suitable for collar joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
1 RCCHPF80001012 600 760.91 2 RCCHPF80001013 700 903.12
Schedule -3: Reinforced Concrete, Medium duty, Non-Pressure Pipes, Class: NP3, with ends of the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
3 RCCHPF80001054 600 1480.50 4 RCCHPF80001057 900 2936.38 5 RCCHPF80001058 1000 3052.39 6 RCCHPF80001060 1200 4378.50
Schedule -7: Reinforced Concrete Collar for Reinforced Concrete Light duty, Non-Pressure Pipes, Class: NP2, conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Reinforced Concrete Collar for the Pipes. Class: NP2, Size (Nominal Diameter in mm.) is as per below:
7 RCCHPF80001138 600 210.00 8 RCCHPF80001139 700 226.38
Schedule - 7 Transportation Charges : Sub Item Code No. Item Description Distance in Km. Transportation Charges in % on the Total Cost of Pipes/Collars.
E.D. VAT/CST Extra 9 RCCHPF80001148 Upto 50 Km. 19.64 10 RCCHPF80001149 Above 50 Km. Upto 100 Km. 21.00 11 RCCHPF80001150 Above 100 Km. Upto 150 Km. 28.88 12 RCCHPF80001151 Above 150 Km. Upto 200 Km. 32.00 13 RCCHPF80001152 Above 200 Km. 37.00
Note :- Technical particulars as per Annexure A enclosed
(Suresh Keshi) General Manager
![Page 142: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/142.jpg)
No. 142/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RP/6478 Dated: 31-03-2015 4. TERMS OF DELIVERY : F. O. R Destination (Any where in C.G.State) 5. EXCISE DUTY : Not Applicable 6. SALES TAX /VAT : Extra, as Applicable
TIN No. 22223601665
Address:- M/s Raj Pipes, Infront of Industrial Estate, G.E. Road, Rajnandgaon (C.G.)
7. DELIVERY PERIOD : 45 Days 8. a. ANNUAL TURN OVER/ : 2011-12 Rs. 5888586.00
2012-13 Rs. 5114377.00 2013-14 Rs. 5849512.00
b. MONETARY LIMIT : Not Mentioned c. INSTALLED CAPACITY : (as per Rajnandgaon DTIC Registration Certificate) Description Capacity/Annum
RCC HUME PIPE 5000 RFT. 9. SLAB DISCOUNT (IF ANY) : Not Mentioned. 10. PRICES : Prices are Firm and Final. 11. MINIMUM QUANTITY IN : Not Mentioned. SINGLE SUPPLY ORDER 12. STATUS OF RC HOLDING : SSI Unit
FIRM
13. REGISTRATION STATUS : Manufacturer is Registered with Rajnandgaon DTIC DTIC EM Part-II 220091100306 Dated 16-12-2010
14 BIS LICENSE : Not Mentioned
15. PAYING AUTHORITY : As Mentioned in supply order to be issued by Direct Demanding Officers (DDOs).
16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each consignment there-of will be made after receipt and acceptance of the stores by the consignee/interim consignee in full and good condition within 20 days as per SPR rule No.11, if the bills are in order. In case of delay in payment without any reason the department will be liable to pay interest as per prevailing bank rate. Bills are to be submitted in the prescribed form of the paying authority of purchaser / indenter and are to be supported with inspection note issued by the inspector and consignee’s Receipt Certificate .
(Suresh Keshi) General Manager
![Page 143: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/143.jpg)
No. 143/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RP/6478 Dated: 31-03-2015
17 INSPECTION AUTHORITY : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah) OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
18 QUALITY ASSURANCE : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah) OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
19. PLACE WHERE THE STORES Manufacturer’s Factory at ARE TO BE OFFERED FOR M/s Raj Pipes, INSPECTION Infront of Industrial Estate,
G.E. Road, Rajnandgaon (C.G.)
20 INSPECTION CHARGES : 0.60% Inspection charges + Service Tax As Applicable to be paid extra at the time of inspection to Quality Assurance Officer which will be billed by the unit along with bill of the material and will be reimbursed by the paying authority of DDO.
(Suresh Keshi)
General Manager
![Page 144: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/144.jpg)
No. 144/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RP/6478 Dated: 31-03-2015
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause
7, the Purchaser / DDOs may require the contractor to furnish a security deposit which shall be made after issue of the acceptance of the supply order within the period specified by the purchaser / DDOs. Such security deposit shall not ordinarily exceed 3% . The security shall be in form of Demand Drafts issued by any of the Scheduled Commercial Banks. No other form of security is to be accepted. The security deposit amount is to be refunded after successful completion of the supply.
22. Special Note 1. Purchasing Departments / end user will ensure to sending the copy of every order to this office for Approval of inspection Agency against inspection of stores. 2. Purchasing Departments / end user will ensure to Pre
Dispatch inspection of stores Through inspection agency in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to obtained the central excise invoices of Manufacturer as mentioned in the Schedule-A vide sr. no. 1-B if excise duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to execute the Integrity Pact between BUYER and BIDDER/SUPPLIEY in accordance with the letter vide no. 799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi) General Manager
![Page 145: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/145.jpg)
No. 145/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RP/6478 Dated: 31-03-2015
Annexure 'A' CSIDC/MKD/TECH/2014-15/14
TECHNICAL PARTICULARS OF R.C.C. HUME PIPES
TSC 15-10-2014
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes (Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish / Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket & Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
The Pipes shall be of the following Sizes & Classification: Schedule- 1: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for collar joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment
Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment. 2. Tenderers may also quote rates separately for the Collars. Dimensions and Design requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003, with up-to-date amendment. Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 146: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/146.jpg)
No. 146/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RP/6478 Dated: 31-03-2015 Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment 2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment. Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
12. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 147: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/147.jpg)
No. 147/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RP/6478 Dated: 31-03-2015 Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter in mm) , is as per below: 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule - 8 Transportation Charges:
Sub Item Code No.
Item Description Distance in km. Transportation Charges in % on the Total Cost of Pipes/ Collars
1 Upto 50 km. 2 Above 50 km. upto 100 km. 3 Above 100 km. upto 150 km. 4 Above 150 km. upto 200 km. 5 Above 200 km.
Inspection & Testing: As per prevailing practice, the following Review of Reports shall be carried out. Review of Reports: The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review: During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively, if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the Inspecting Officer for review.
(K.N.K. Mishra) Incharge PS-VII
![Page 148: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/148.jpg)
No. 148/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RP/6478 Dated: 31-03-2015 1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes. 2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement. 3. Manufacture’s Test Repot of Rubber Rings shall be submitted for review (incase of Pipes with Socket & Spigot ends). TESTS: As per prevailing practice, the following Tests / Checking shall be carried out. 1. Visual examination, 2. Permeability Test and 3. Three Edge Bearing Test to produce 0.25 mm crack. 4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date amendment shall be carried out if desired by the Consignee. NOTE: 1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. The length in which the pipes are to be supplied shall be as per the mutual agreement between the purchaser and the supplier. However, the recommended length above 300 mm Nominal Diameter is 2.5 meters. 4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. 6. The following information shall be shall be clearly marked on the each Finished Pipe. a. Size of Pipe, b. Class of Pipe, and c. Name of manufacture. 7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of receipt of the materials by the consignee. 8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment towards the supply of Rubber rings will be made) as per the prevailing practice, transportation cost for Pipes & Collars shall be quoted separately.
Recommended by Technical Specification Committee Dated 15-10-2014
(K.N.K. Mishra) Incharge PS-VII
![Page 149: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/149.jpg)
No. 149/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RP/6478 Dated: 31-03-2015
SCHEDULE ‘B’ (SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi) General Manager
![Page 150: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/150.jpg)
No. 150/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RP/6478 Dated: 31-03-2015
SCHEDULE – “D”
FORMAT FOR QUATERLY DRAWAL REPORT
Name of the Firm __________________ I- Jan-Mar Report No. __________________ II- Apr-June Rate Contract No. __________________ III- July-Sept. Date of Submission __________________ IV- Oct - Dec Total Position of Order against Rate Contract till the submission of Report. S.No. Name of
Department Quantity and Value of Orders Received (Rs.)
Quantity and Value of Orders Executed (Rs.)
Balance Quantity and Value to be Supplied (Rs.)
Reasons
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all Taxes duties and incidental b) Value of orders supplied during the quarter-Rs. Charges
2. Nil report should also be Submitted.
(Suresh Keshi) General Manager
![Page 151: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/151.jpg)
No. 151/336 S Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking) First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.) EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt) CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004 Website: www.csidc.in, Email : [email protected], [email protected]
No./CSIDC/MKD/ PS-VII /14-15/ Raipur, Dated :
Registered A/D Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/API/6479 Dated: 31-03-2015 To,
M/s Akash Pipe Industries, Dharampara Mungeli Bilaspur (C.G.) 495334 Mo.- 9993070099
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 31-03-2015 to 01-04-2016) Ref :- (I) This Office Tender Enquiry No. PS-VII/CSIDC/MKD/102/510/14-15
(II) Bid No. 8426 Dated 18-11-2014 (III) Your Offer acceptance alongwith undertaking submitted on dated 27-03-2015
Dear Sir, You are hereby informed that your above referred tender read with subsequent letters mentioned above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction. You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the time of getting the payment. SCHEDULES ANNEXED: 1. Schedule “A” Description of Stores, Prices, Duties/Taxes . 2. Annexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions of contract (if any). 4. Schedule “C” Information to DDOs about parallel rate contracts. 5. Schedule “D” Format for Drawal Report. Encl. 15 pages
Yours faithfully,
(Suresh Keshi) General Manager
For and on behalf of the purchaser Named in CSIDC Form No.2
![Page 152: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/152.jpg)
No. 152/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/API/6479 Dated: 31-03-2015 Copy to, 1. The Secretary, Chhattisgarh Vidhan Sabha ,Raipur .
2. The Registrar, Honourable High court Chhattisgarh, Bilaspur .
3. The Accountant General Chhattisgarh State, Raipur.
4. All HODs of Chhattisgarh Govt. with a request to circulate the copy of R/C to all Direct Demanding Officers of your institution against issue of purchase order (Indent) in Favour of Rate Contract Holders of CSIDC.
5. All Collectors, Chhattisgarh State against issue of purchase order (Indent) in Favour of Rate Contract holders of CSIDC.
6. The Director Treasury, Chhattisgarh Govt., Raipur with a request to circulate copy of R/C to all branches under your control .
7. (i) Director of Public Instruction Department Pension Bada Raipur (ii) Engineer in Chief PHED C.G. Neer Bhawan, Raipur (iii) The Commissioner , Local Administrator , RDA Building Raipur (iv) Engineer in Chief PWD C.G.Civil lines Raipur .
Sr. No. 1 to 7 above are requested to call for original INK-SIGNED Rate Contract for verification to their full satisfaction including validity of various documents like Registration, Tax Registration etc. before taking action i.e. against issue of purchase order in Favour of Rate Contract holders of CSIDC, pre dispatched inspection of stores, acceptance of store.
8. (i) Dy.Director (Q.A.) , DGS&D, Bhilai, Durg (C.G.). (ii) Manager (Operation) Indian Register of Shipping, Senior MIG-2, Secter A, 1st Floor,
Infront of Bank of India Indrapuri Bhopal. (iii) Chief Engineer, PDIL, 4th floor, 4/2 Karaya Road, 67 Shekespeare Sarani, Kolkata (W.B.) (iv) General Manager (Inspection) RITES Ltd., Church gate Station Road, Second Floor, M.K.
Road, Mumbai-400020 (v) Operations Manager SGS India Pvt, Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal (MP)-
462011. above (i) to (v) are requested to call for original INK-SIGNED Rate Contract For Verification to their full satisfaction including validity of various documents like Validity of Registration, BIS Registration etc. before taking action i.e. inspection of stores, as the responsibility rests with the concerned authority. For information and necessary action against Authorized Inspection Agency accorded by CSIDC for inspection of stores.
9. Incharge, Monitoring Cell, MKT-1 CSIDC, Ltd. Raipur for necessary action against inspection of stores . 10. Manager (Tender), Marketing Div., CSIDC Ltd., Raipur. He is requested to maintain a master file
of Rate Contract. 11. Computer cell, CSIDC Ltd., Raipur to release Rate Contract on CSIDC website.
12. Main file of Item- RCC HUME PIPE
(Suresh Keshi) General Manager
![Page 153: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/153.jpg)
No. 153/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/API/6479 Dated: 31-03-2015
SCHEDULE “A” Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per Annexure’A’ enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Akash Pipe Industries, THE FIRM Dharampara Mungeli Bilaspur (C.G.) 495334
Mo.- 9993070099 (b) NAME AND FULL ADDRESS OF :- M/s Akash Pipe Industries,
MANUFACTURER Dharampara Mungeli Bilaspur (C.G.) 495334 Mo.- 9993070099
(C) Category :- General 2. VALIDITY OF RATE CONTRACT :- From 31-03-2015 To 01-04-2016 15. DESCRIPTION OF ITEM- RCC HUME PIPE SPECIFICATION, UNIT RATE AS BELOW
S.No. Item Code No. Item Description Class Rate ( )
E.D. VAT/CST Extra As Applicable
Rate Per Meter
Schedule -1: Reinforced Concrete, Light duty, Non-Pressure Pipes, Class: NP2, with ends of the Pipes suitable for collar joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
1 RCCHPF80001001 80 103.95 2 RCCHPF80001002 100 104.78 3 RCCHPF80001003 150 208.95
4 RCCHPF80001004 200 202.08 5 RCCHPF80001005 225 233.27 6 RCCHPF80001006 250 241.99 7 RCCHPF80001008 350 350.52 8 RCCHPF80001009 400 440.33 9 RCCHPF80001010 450 449.06
10 RCCHPF80001011 500 600.00 11 RCCHPF80001012 600 760.91 12 RCCHPF80001013 700 903.12 13 RCCHPF80001014 800 1307.27 14 RCCHPF80001015 900 1155.00 15 RCCHPF80001016 1000 1212.75 16 RCCHPF80001018 1200 1501.50 17 RCCHPF80001019 1400 3117.25 18 RCCHPF80001020 1600 3871.93 19 RCCHPF80001021 1800 4479.42
Schedule -2: Reinforced Concrete, Light duty, Non-Pressure Pipes, Class: NP2, with ends of the Pipes Suitable for Socket & Spigot, roll & joints or confined gasket joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm.
(Suresh Keshi) General Manager
![Page 154: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/154.jpg)
No. 154/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/API/6479 Dated: 31-03-2015
20 RCCHPF80001022 80 32.49 21 RCCHPF80001023 100 35.81 22 RCCHPF80001024 150 42.11 23 RCCHPF80001025 200 51.98 24 RCCHPF80001026 225 61.22 25 RCCHPF80001027 250 63.53 26 RCCHPF80001028 300 76.23 27 RCCHPF80001029 350 88.94 28 RCCHPF80001030 400 128.21 29 RCCHPF80001031 450 140.33 30 RCCHPF80001032 500 187.50 31 RCCHPF80001033 600 217.14 32 RCCHPF80001034 700 226.38 33 RCCHPF80001035 800 243.71 34 RCCHPF80001036 900 360.94 35 RCCHPF80001037 1000 378.99 36 RCCHPF80001038 1100 577.50 37 RCCHPF80001039 1200 706.86 38 RCCHPF80001040 1400 974.14 39 RCCHPF80001041 1600 1099.56 40 RCCHPF80001042 1800 1398.71
Schedule -3: Reinforced Concrete, Medium duty, Non-Pressure Pipes, Class: NP3, with ends of the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
41 RCCHPF80001043 80 106.59 42 RCCHPF80001044 100 130.98 43 RCCHPF80001045 150 183.37 44 RCCHPF80001046 200 264.45 45 RCCHPF80001047 225 275.68 46 RCCHPF80001048 250 309.35 47 RCCHPF80001049 300 309.35 48 RCCHPF80001050 350 415.80 49 RCCHPF80001051 400 462.00 50 RCCHPF80001052 450 1050.00 51 RCCHPF80001053 500 1155.00 52 RCCHPF80001054 600 1480.50 53 RCCHPF80001055 700 1680.00 54 RCCHPF80001056 800 2250.00 55 RCCHPF80001057 900 2936.38 56 RCCHPF80001058 1000 3052.39 57 RCCHPF80001059 1100 3465.00 58 RCCHPF80001060 1200 4378.50 59 RCCHPF80001061 1400 5911.43 60 RCCHPF80001062 1600 7045.31 61 RCCHPF80001063 1800 7793.75
Schedule -5: Reinforced Concrete, Heavy duty, Non-Pressure Pipes, Class: NP4, with ends of the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
(Suresh Keshi)
General Manager
![Page 155: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/155.jpg)
No. 155/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/API/6479 Dated: 31-03-2015
62 RCCHPF80001085 80 128.48 63 RCCHPF80001086 100 149.69 64 RCCHPF80001087 150 202.08 65 RCCHPF80001088 200 302.61 66 RCCHPF80001089 225 324.32 67 RCCHPF80001090 250 374.22 68 RCCHPF80001091 300 415.80 69 RCCHPF80001092 350 462.00 70 RCCHPF80001093 400 485.10 71 RCCHPF80001094 450 1037.84 72 RCCHPF80001095 500 1239.91 73 RCCHPF80001096 600 1386.00 74 RCCHPF80001097 700 1732.50 75 RCCHPF80001098 800 1963.50 76 RCCHPF80001099 900 2772.00 77 RCCHPF80001100 1000 3291.75 78 RCCHPF80001101 1100 3407.25 79 RCCHPF80001102 1200 4389.00 80 RCCHPF80001103 1400 5313.00 81 RCCHPF80001104 1600 7507.50
Schedule -7: Reinforced Concrete Collar for Reinforced Concrete Light duty, Non-Pressure Pipes, Class: NP2, conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Reinforced Concrete Collar for the Pipes. Class: NP2, Size (Nominal Diameter in mm.) is as per below:
82 RCCHPF80001127 80 31.50 83 RCCHPF80001128 100 35.81 84 RCCHPF80001129 150 42.11 85 RCCHPF80001130 200 51.98 86 RCCHPF80001131 225 61.22 87 RCCHPF80001132 250 63.53 88 RCCHPF80001133 300 76.23 89 RCCHPF80001134 350 88.94 90 RCCHPF80001135 400 128.21 91 RCCHPF80001136 450 140.33 92 RCCHPF80001137 500 187.50 93 RCCHPF80001138 600 210.00 94 RCCHPF80001139 700 226.38 95 RCCHPF80001140 800 243.71 96 RCCHPF80001141 900 315.00 97 RCCHPF80001142 1000 378.99 98 RCCHPF80001143 1100 525.00 99 RCCHPF80001144 1200 577.50
100 RCCHPF80001145 1400 735.00 101 RCCHPF80001146 1600 840.00 102 RCCHPF80001147 1800 1050.00
(Suresh Keshi) General Manager
![Page 156: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/156.jpg)
No. 156/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/API/6479 Dated: 31-03-2015
Schedule - 7 Transportation Charges : Sub Item Code No. Item Description Distance in Km. Transportation Charges in % on the Total Cost of Pipes/Collars.
E.D. VAT/CST Extra 103 RCCHPF80001148 Upto 50 Km. 19.64 104 RCCHPF80001149 Above 50 Km. Upto 100 Km. 21.00 105 RCCHPF80001150 Above 100 Km. Upto 150 Km. 28.88 106 RCCHPF80001151 Above 150 Km. Upto 200 Km. 32.00 107 RCCHPF80001152 Above 200 Km. 37.00
Note :- Technical particulars as per Annexure A enclosed 4. TERMS OF DELIVERY : F. O. R Destination (Any where in C.G.State) 5. EXCISE DUTY : Not Applicable 6. SALES TAX /VAT : Extra, as Applicable
TIN No. 22554301678 Address:-
M/s Akash Pipe Industries, Dharampara Mungeli Bilaspur (C.G.) 495334 Mo.- 9993070099
7. DELIVERY PERIOD : 45 Days 8. a. ANNUAL TURN OVER/ : NM
b. MONETARY LIMIT : Not Mentioned c. INSTALLED CAPACITY : (as per Mungeli DTIC Registration Certificate) Description Capacity/Annum
RCC HUME PIPE 6000 Nos.
9. SLAB DISCOUNT (IF ANY) : Not Mentioned. 10. PRICES : Prices are Firm and Final 11. MINIMUM QUANTITY IN : Not Mentioned. SINGLE SUPPLY ORDER 12. STATUS OF RC HOLDING : Manufacturer
FIRM
13. REGISTRATION STATUS : Manufacturer is Registered with Mungeli DTIC DTIC EM Part- II 220071100292 Dated 06-10-2009
14 BIS LICENSE : Not Mentioned
15. PAYING AUTHORITY : As Mentioned in supply order to be issued by Direct Demanding Officers (DDOs).
(Suresh Keshi) General Manager
![Page 157: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/157.jpg)
No. 157/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/API/6479 Dated: 31-03-2015
16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each
consignment there-of will be made after receipt and acceptance of the stores by the consignee/interim consignee in full and good condition within 20 days as per SPR rule No.11, if the bills are in order. In case of delay in payment without any reason the department will be liable to pay interest as per prevailing bank rate. Bills are to be submitted in the prescribed form of the paying authority of purchaser / indenter and are to be supported with inspection note issued by the inspector and consignee’s Receipt Certificate .
17 INSPECTION AUTHORITY : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah) OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
18 QUALITY ASSURANCE : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah)
OR Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
19. PLACE WHERE THE STORES Manufacturer’s Factory at ARE TO BE OFFERED FOR M/s Akash Pipe Industries, INSPECTION Dharampara Mungeli Bilaspur (C.G.) 495334
Mo.- 9993070099
(Suresh Keshi)
General Manager
![Page 158: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/158.jpg)
No. 158/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/API/6479 Dated: 31-03-2015
20 INSPECTION CHARGES : 0.60% Inspection charges + Service Tax As Applicable to be
paid extra at the time of inspection to Quality Assurance Officer which will be billed by the unit along with bill of the material and will be reimbursed by the paying authority of DDO.
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause 7, the Purchaser / DDOs may require the contractor to furnish a security deposit which shall be made after issue of the acceptance of the supply order within the period specified by the purchaser / DDOs. Such security deposit shall not ordinarily exceed 3% . The security shall be in form of Demand Drafts issued by any of the Scheduled Commercial Banks. No other form of security is to be accepted. The security deposit amount is to be refunded after successful completion of the supply.
22. Special Note 1. Purchasing Departments / end user will ensure to sending the copy of every order to this office for Approval of inspection Agency against inspection of stores. 2. Purchasing Departments / end user will ensure to Pre
Dispatch inspection of stores Through inspection agency in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to obtained the central excise invoices of Manufacturer as mentioned in the Schedule-A vide sr. no. 1-B if excise duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to execute the Integrity Pact between BUYER and BIDDER/SUPPLIEY in accordance with the letter vide no. 799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi) General Manager
![Page 159: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/159.jpg)
No. 159/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/API/6479 Dated: 31-03-2015
Annexure 'A' CSIDC/MKD/TECH/2014-15/14
TECHNICAL PARTICULARS OF R.C.C. HUME PIPES
TSC 15-10-2014
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes (Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish / Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket & Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
The Pipes shall be of the following Sizes & Classification: Schedule- 1: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for collar joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment
Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment. 2. Tenderers may also quote rates separately for the Collars. Dimensions and Design requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003, with up-to-date amendment. Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 160: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/160.jpg)
No. 160/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/API/6479 Dated: 31-03-2015 Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment 2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment. Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
13. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 161: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/161.jpg)
No. 161/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/API/6479 Dated: 31-03-2015 Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter in mm) , is as per below: 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule - 8 Transportation Charges:
Sub Item Code No.
Item Description Distance in km. Transportation Charges in % on the Total Cost of Pipes/ Collars
1 Upto 50 km. 2 Above 50 km. upto 100 km. 3 Above 100 km. upto 150 km. 4 Above 150 km. upto 200 km. 5 Above 200 km.
Inspection & Testing: As per prevailing practice, the following Review of Reports shall be carried out. Review of Reports: The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review: During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively, if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the Inspecting Officer for review.
(K.N.K. Mishra) Incharge PS-VII
![Page 162: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/162.jpg)
No. 162/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/API/6479 Dated: 31-03-2015 1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes. 2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement. 3. Manufacture’s Test Repot of Rubber Rings shall be submitted for review (incase of Pipes with Socket & Spigot ends). TESTS: As per prevailing practice, the following Tests / Checking shall be carried out. 1. Visual examination, 2. Permeability Test and 3. Three Edge Bearing Test to produce 0.25 mm crack. 4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date amendment shall be carried out if desired by the Consignee. NOTE: 1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. The length in which the pipes are to be supplied shall be as per the mutual agreement between the purchaser and the supplier. However, the recommended length above 300 mm Nominal Diameter is 2.5 meters. 4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. 6. The following information shall be shall be clearly marked on the each Finished Pipe. a. Size of Pipe, b. Class of Pipe, and c. Name of manufacture. 7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of receipt of the materials by the consignee. 8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment towards the supply of Rubber rings will be made) as per the prevailing practice, transportation cost for Pipes & Collars shall be quoted separately.
Recommended by Technical Specification Committee Dated 15-10-2014
(K.N.K. Mishra) Incharge PS-VII
![Page 163: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/163.jpg)
No. 163/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/API/6479 Dated: 31-03-2015
SCHEDULE ‘B’ (SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi) General Manager
![Page 164: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/164.jpg)
No. 164/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/API/6479 Dated: 31-03-2015
SCHEDULE – “D”
FORMAT FOR QUATERLY DRAWAL REPORT
Name of the Firm __________________ I- Jan-Mar Report No. __________________ II- Apr-June Rate Contract No. __________________ III- July-Sept. Date of Submission __________________ IV- Oct - Dec Total Position of Order against Rate Contract till the submission of Report. S.No. Name of
Department Quantity and Value of Orders Received (Rs.)
Quantity and Value of Orders Executed (Rs.)
Balance Quantity and Value to be Supplied (Rs.)
Reasons
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all Taxes duties and incidental b) Value of orders supplied during the quarter-Rs. Charges
2. Nil report should also be Submitted.
(Suresh Keshi) General Manager
![Page 165: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/165.jpg)
No. 165/336 S Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking) First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.) EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt) CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004 Website: www.csidc.in, Email : [email protected], [email protected]
No./CSIDC/MKD/ PS-VII /14-15/ Raipur, Dated :
Registered A/D Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/KCP/6480 Dated: 31-03-2015 To,
M/s Korba Cement Products, Urga-Korba (C.G.) Mo.- 9425224499 Email- [email protected]
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 31-03-2015 to 01-04-2016) Ref :- (I) This Office Tender Enquiry No. PS-VII/CSIDC/MKD/102/510/14-15
(II) Bid No. 8430 Dated 18-11-2014 (III) Your Offer acceptance alongwith undertaking submitted on dated 27-03-2015
Dear Sir, You are hereby informed that your above referred tender read with subsequent letters mentioned above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction. You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the time of getting the payment. SCHEDULES ANNEXED: 1. Schedule “A” Description of Stores, Prices, Duties/Taxes . 2. Annexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions of contract (if any). 4. Schedule “C” Information to DDOs about parallel rate contracts. 5. Schedule “D” Format for Drawal Report. Encl. 14 pages
Yours faithfully,
(Suresh Keshi) General Manager
For and on behalf of the purchaser Named in CSIDC Form No.2
![Page 166: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/166.jpg)
No. 166/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/KCP/6480 Dated: 31-03-2015 Copy to, 1. The Secretary, Chhattisgarh Vidhan Sabha ,Raipur .
2. The Registrar, Honourable High court Chhattisgarh, Bilaspur .
3. The Accountant General Chhattisgarh State, Raipur.
4. All HODs of Chhattisgarh Govt. with a request to circulate the copy of R/C to all Direct Demanding Officers of your institution against issue of purchase order (Indent) in Favour of Rate Contract Holders of CSIDC.
5. All Collectors, Chhattisgarh State against issue of purchase order (Indent) in Favour of Rate Contract holders of CSIDC.
6. The Director Treasury, Chhattisgarh Govt., Raipur with a request to circulate copy of R/C to all branches under your control .
7. (i) Director of Public Instruction Department Pension Bada Raipur (ii) Engineer in Chief PHED C.G. Neer Bhawan, Raipur (iii) The Commissioner , Local Administrator , RDA Building Raipur (iv) Engineer in Chief PWD C.G.Civil lines Raipur .
Sr. No. 1 to 7 above are requested to call for original INK-SIGNED Rate Contract for verification to their full satisfaction including validity of various documents like Registration, Tax Registration etc. before taking action i.e. against issue of purchase order in Favour of Rate Contract holders of CSIDC, pre dispatched inspection of stores, acceptance of store.
8. (i) Dy.Director (Q.A.) , DGS&D, Bhilai, Durg (C.G.). (ii) Manager (Operation) Indian Register of Shipping, Senior MIG-2, Secter A, 1st Floor,
Infront of Bank of India Indrapuri Bhopal. (iii) Chief Engineer, PDIL, 4th floor, 4/2 Karaya Road, 67 Shekespeare Sarani, Kolkata (W.B.) (iv) General Manager (Inspection) RITES Ltd., Church gate Station Road, Second Floor, M.K.
Road, Mumbai-400020 (v) Operations Manager SGS India Pvt, Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal (MP)-
462011. above (i) to (v) are requested to call for original INK-SIGNED Rate Contract For Verification to their full satisfaction including validity of various documents like Validity of Registration, BIS Registration etc. before taking action i.e. inspection of stores, as the responsibility rests with the concerned authority. For information and necessary action against Authorized Inspection Agency accorded by CSIDC for inspection of stores.
9. Incharge, Monitoring Cell, MKT-1 CSIDC, Ltd. Raipur for necessary action against inspection of stores . 10. Manager (Tender), Marketing Div., CSIDC Ltd., Raipur. He is requested to maintain a master file
of Rate Contract. 11. Computer cell, CSIDC Ltd., Raipur to release Rate Contract on CSIDC website.
12. Main file of Item- RCC HUME PIPE
(Suresh Keshi) General Manager
![Page 167: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/167.jpg)
No. 167/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/KCP/6480 Dated: 31-03-2015
SCHEDULE “A” Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per Annexure’A’ enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Korba Cement Products, THE FIRM Urga-Korba (C.G.)
Mo.- 9425224499 Email- [email protected]
(b) NAME AND FULL ADDRESS OF :- M/s Korba Cement Products,
MANUFACTURER Urga-Korba (C.G.) Mo.- 9425224499 Email- [email protected]
(C) Category :- General 2. VALIDITY OF RATE CONTRACT :- From 31-03-2015 To 01-04-2016 16. DESCRIPTION OF ITEM- RCC HUME PIPE SPECIFICATION, UNIT RATE AS BELOW
S.No. Item Code No. Item Description Class Rate ( )
E.D. VAT/CST Extra As Applicable
Rate Per Meter
Schedule -1: Reinforced Concrete, Light duty, Non-Pressure Pipes, Class: NP2, with ends of the Pipes suitable for collar joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
1 RCCHPF80001003 150 208.95
2 RCCHPF80001004 200 202.08 3 RCCHPF80001006 250 241.99 4 RCCHPF80001008 350 350.52 5 RCCHPF80001009 400 440.33 6 RCCHPF80001010 450 449.06 7 RCCHPF80001011 500 600.00 8 RCCHPF80001012 600 760.91 9 RCCHPF80001015 900 1155.00 10 RCCHPF80001016 1000 1212.75 11 RCCHPF80001018 1200 1501.50 12 RCCHPF80001019 1400 3117.25 13 RCCHPF80001020 1600 3871.93 14 RCCHPF80001021 1800 4479.42
Schedule -3: Reinforced Concrete, Medium duty, Non-Pressure Pipes, Class: NP3, with ends of the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
15 RCCHPF80001049 300 309.35 16 RCCHPF80001050 350 415.80 17 RCCHPF80001051 400 462.00 18 RCCHPF80001052 450 1050.00
(Suresh Keshi) General Manager
![Page 168: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/168.jpg)
No. 168/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/KCP/6480 Dated: 31-03-2015
19 RCCHPF80001053 500 1155.00 20 RCCHPF80001054 600 1480.50 21 RCCHPF80001055 700 1680.00 22 RCCHPF80001056 800 2250.00 23 RCCHPF80001057 900 2936.38 24 RCCHPF80001058 1000 3052.39 25 RCCHPF80001060 1200 4378.50 26 RCCHPF80001061 1400 5911.43 27 RCCHPF80001062 1600 7045.31 28 RCCHPF80001063 1800 7793.75
Schedule -5: Reinforced Concrete, Heavy duty, Non-Pressure Pipes, Class: NP4, with ends of the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
29 RCCHPF80001091 300 415.80 30 RCCHPF80001092 350 462.00 31 RCCHPF80001093 400 485.10 32 RCCHPF80001094 450 1037.84 33 RCCHPF80001095 500 1239.91 34 RCCHPF80001096 600 1386.00 35 RCCHPF80001097 700 1732.50 36 RCCHPF80001098 800 1963.50 37 RCCHPF80001099 900 2772.00 38 RCCHPF80001100 1000 3291.75 39 RCCHPF80001102 1200 4389.00 40 RCCHPF80001103 1400 5313.00 41 RCCHPF80001104 1600 7507.50
Schedule -7: Reinforced Concrete Collar for Reinforced Concrete Light duty, Non-Pressure Pipes, Class: NP2, conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Reinforced Concrete Collar for the Pipes. Class: NP2, Size (Nominal Diameter in mm.) is as per below:
42 RCCHPF80001129 150 42.11 43 RCCHPF80001130 200 51.98 44 RCCHPF80001132 250 63.53 45 RCCHPF80001133 300 76.23 46 RCCHPF80001134 350 88.94 47 RCCHPF80001135 400 128.21 48 RCCHPF80001136 450 140.33 49 RCCHPF80001137 500 187.50 50 RCCHPF80001138 600 210.00 51 RCCHPF80001141 900 315.00 52 RCCHPF80001142 1000 378.99 53 RCCHPF80001144 1200 577.50 54 RCCHPF80001145 1400 735.00 55 RCCHPF80001146 1600 840.00 56 RCCHPF80001147 1800 1050.00
Schedule - 7 Transportation Charges : Sub Item Code No. Item Description Distance in Km. Transportation Charges in % on the Total Cost of Pipes/Collars.
E.D. VAT/CST Extra 57 RCCHPF80001148 Upto 50 Km. 19.64
(Suresh Keshi)
General Manager
![Page 169: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/169.jpg)
No. 169/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/KCP/6480 Dated: 31-03-2015
58 RCCHPF80001149 Above 50 Km. Upto 100 Km. 21.00 59 RCCHPF80001150 Above 100 Km. Upto 150 Km. 28.88 60 RCCHPF80001151 Above 150 Km. Upto 200 Km. 32.00 61 RCCHPF80001152 Above 200 Km. 37.00
Note :- Technical particulars as per Annexure A enclosed 4. TERMS OF DELIVERY : F. O. R Destination (Any where in C.G.State) 5. EXCISE DUTY : Not Applicable 6. SALES TAX /VAT : Extra, as Applicable
TIN No. 22155200312 Address:-
M/s Korba Cement Products, Urga-Korba (C.G.) Mo.- 9425224499 Email- [email protected]
7. DELIVERY PERIOD : 45 Days 8. a. ANNUAL TURN OVER/ : 2011-12 Rs. 10215024.00
2012-13 Rs. 15225481.00 2013-14 Rs. 18343743.00
b. MONETARY LIMIT : Not Mentioned c. INSTALLED CAPACITY : (as per Korba DTIC Registration Certificate) Description Capacity/Annum
RCC HUME PIPE 1200 Nos. 9. SLAB DISCOUNT (IF ANY) : Not Mentioned. 10. PRICES : Prices are Firm and Final 11. MINIMUM QUANTITY IN : Not Mentioned. SINGLE SUPPLY ORDER 12. STATUS OF RC HOLDING : SSI Unit
FIRM 13. REGISTRATION STATUS : Manufacturer is Registered with Korba DTIC DTIC EM Part- II 220051100146 Dated 10-06-2009
14 BIS LICENSE : Not Mentioned
15. PAYING AUTHORITY : As Mentioned in supply order to be issued by Direct Demanding Officers (DDOs).
(Suresh Keshi) General Manager
![Page 170: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/170.jpg)
No. 170/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/KCP/6480 Dated: 31-03-2015 16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each
consignment there-of will be made after receipt and acceptance of the stores by the consignee/interim consignee in full and good condition within 20 days as per SPR rule No.11, if the bills are in order. In case of delay in payment without any reason the department will be liable to pay interest as per prevailing bank rate. Bills are to be submitted in the prescribed form of the paying authority of purchaser / indenter and are to be supported with inspection note issued by the inspector and consignee’s Receipt Certificate .
17 INSPECTION AUTHORITY : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah) OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
18 QUALITY ASSURANCE : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah)
OR Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
19. PLACE WHERE THE STORES Manufacturer’s Factory at ARE TO BE OFFERED FOR M/s Korba Cement Products, INSPECTION Urga-Korba (C.G.)
Mo.- 9425224499 Email- [email protected]
(Suresh Keshi) General Manager
![Page 171: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/171.jpg)
No. 171/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/KCP/6480 Dated: 31-03-2015
20 INSPECTION CHARGES : 0.60% Inspection charges + Service Tax As Applicable to be
paid extra at the time of inspection to Quality Assurance Officer which will be billed by the unit along with bill of the material and will be reimbursed by the paying authority of DDO.
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause
7, the Purchaser / DDOs may require the contractor to furnish a security deposit which shall be made after issue of the acceptance of the supply order within the period specified by the purchaser / DDOs. Such security deposit shall not ordinarily exceed 3% . The security shall be in form of Demand Drafts issued by any of the Scheduled Commercial Banks. No other form of security is to be accepted. The security deposit amount is to be refunded after successful completion of the supply.
22. Special Note 1. Purchasing Departments / end user will ensure to sending the copy of every order to this office for Approval of inspection Agency against inspection of stores. 2. Purchasing Departments / end user will ensure to Pre
Dispatch inspection of stores Through inspection agency in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to obtained the central excise invoices of Manufacturer as mentioned in the Schedule-A vide sr. no. 1-B if excise duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to execute the Integrity Pact between BUYER and BIDDER/SUPPLIEY in accordance with the letter vide no. 799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi) General Manager
![Page 172: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/172.jpg)
No. 172/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/KCP/6480 Dated: 31-03-2015
Annexure 'A' CSIDC/MKD/TECH/2014-15/14
TECHNICAL PARTICULARS OF R.C.C. HUME PIPES
TSC 15-10-2014
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes (Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish / Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket & Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
The Pipes shall be of the following Sizes & Classification: Schedule- 1: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for collar joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment
Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment. 2. Tenderers may also quote rates separately for the Collars. Dimensions and Design requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003, with up-to-date amendment. Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 173: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/173.jpg)
No. 173/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/KCP/6480 Dated: 31-03-2015 Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment 2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment. Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
14. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 174: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/174.jpg)
No. 174/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/KCP/6480 Dated: 31-03-2015 Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter in mm) , is as per below: 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule - 8 Transportation Charges:
Sub Item Code No.
Item Description Distance in km. Transportation Charges in % on the Total Cost of Pipes/ Collars
1 Upto 50 km. 2 Above 50 km. upto 100 km. 3 Above 100 km. upto 150 km. 4 Above 150 km. upto 200 km. 5 Above 200 km.
Inspection & Testing: As per prevailing practice, the following Review of Reports shall be carried out. Review of Reports: The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review: During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively, if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the Inspecting Officer for review.
(K.N.K. Mishra) Incharge PS-VII
![Page 175: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/175.jpg)
No. 175/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/KCP/6480 Dated: 31-03-2015 1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes. 2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement. 3. Manufacture’s Test Repot of Rubber Rings shall be submitted for review (incase of Pipes with Socket & Spigot ends). TESTS: As per prevailing practice, the following Tests / Checking shall be carried out. 1. Visual examination, 2. Permeability Test and 3. Three Edge Bearing Test to produce 0.25 mm crack. 4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date amendment shall be carried out if desired by the Consignee. NOTE: 1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. The length in which the pipes are to be supplied shall be as per the mutual agreement between the purchaser and the supplier. However, the recommended length above 300 mm Nominal Diameter is 2.5 meters. 4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. 6. The following information shall be shall be clearly marked on the each Finished Pipe. a. Size of Pipe, b. Class of Pipe, and c. Name of manufacture. 7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of receipt of the materials by the consignee. 8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment towards the supply of Rubber rings will be made) as per the prevailing practice, transportation cost for Pipes & Collars shall be quoted separately.
Recommended by Technical Specification Committee Dated 15-10-2014
(K.N.K. Mishra) Incharge PS-VII
![Page 176: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/176.jpg)
No. 176/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/KCP/6480 Dated: 31-03-2015
SCHEDULE ‘B’ (SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi) General Manager
![Page 177: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/177.jpg)
No. 177/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/KCP/6480 Dated: 31-03-2015
SCHEDULE – “D”
FORMAT FOR QUATERLY DRAWAL REPORT
Name of the Firm __________________ I- Jan-Mar Report No. __________________ II- Apr-June Rate Contract No. __________________ III- July-Sept. Date of Submission __________________ IV- Oct - Dec Total Position of Order against Rate Contract till the submission of Report. S.No. Name of
Department Quantity and Value of Orders Received (Rs.)
Quantity and Value of Orders Executed (Rs.)
Balance Quantity and Value to be Supplied (Rs.)
Reasons
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all Taxes duties and incidental b) Value of orders supplied during the quarter-Rs. Charges
2. Nil report should also be Submitted.
(Suresh Keshi) General Manager
![Page 178: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/178.jpg)
No. 178/336 S Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking) First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.) EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt) CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004 Website: www.csidc.in, Email : [email protected], [email protected]
No./CSIDC/MKD/ PS-VII /14-15/ Raipur, Dated :
Registered A/D Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/DCP/6481 Dated: 31-03-2015 To,
M/s Dhansree Concrete Products , Manendragarh Road Ambikapur (C.G.) 497001 Mo.- 9425580211
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 31-03-2015 to 01-04-2016) Ref :- (I) This Office Tender Enquiry No. PS-VII/CSIDC/MKD/102/510/14-15
(II) Bid No. 8428 Dated 18-11-2014 (III) Your Offer acceptance alongwith undertaking submitted on dated 27-03-2015
Dear Sir, You are hereby informed that your above referred tender read with subsequent letters mentioned above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction. You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the time of getting the payment. SCHEDULES ANNEXED: 1. Schedule “A” Description of Stores, Prices, Duties/Taxes . 2. Annexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions of contract (if any). 4. Schedule “C” Information to DDOs about parallel rate contracts. 5. Schedule “D” Format for Drawal Report. Encl. 13 pages
Yours faithfully,
(Suresh Keshi) General Manager
For and on behalf of the purchaser Named in CSIDC Form No.2
![Page 179: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/179.jpg)
No. 179/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/DCP/6481 Dated: 31-03-2015 Copy to, 1. The Secretary, Chhattisgarh Vidhan Sabha ,Raipur .
2. The Registrar, Honourable High court Chhattisgarh, Bilaspur .
3. The Accountant General Chhattisgarh State, Raipur.
4. All HODs of Chhattisgarh Govt. with a request to circulate the copy of R/C to all Direct Demanding Officers of your institution against issue of purchase order (Indent) in Favour of Rate Contract Holders of CSIDC.
5. All Collectors, Chhattisgarh State against issue of purchase order (Indent) in Favour of Rate Contract holders of CSIDC.
6. The Director Treasury, Chhattisgarh Govt., Raipur with a request to circulate copy of R/C to all branches under your control .
7. (i) Director of Public Instruction Department Pension Bada Raipur (ii) Engineer in Chief PHED C.G. Neer Bhawan, Raipur (iii) The Commissioner , Local Administrator , RDA Building Raipur (iv) Engineer in Chief PWD C.G.Civil lines Raipur .
Sr. No. 1 to 7 above are requested to call for original INK-SIGNED Rate Contract for verification to their full satisfaction including validity of various documents like Registration, Tax Registration etc. before taking action i.e. against issue of purchase order in Favour of Rate Contract holders of CSIDC, pre dispatched inspection of stores, acceptance of store.
8. (i) Dy.Director (Q.A.) , DGS&D, Bhilai, Durg (C.G.). (ii) Manager (Operation) Indian Register of Shipping, Senior MIG-2, Secter A, 1st Floor,
Infront of Bank of India Indrapuri Bhopal. (iii) Chief Engineer, PDIL, 4th floor, 4/2 Karaya Road, 67 Shekespeare Sarani, Kolkata (W.B.) (iv) General Manager (Inspection) RITES Ltd., Church gate Station Road, Second Floor, M.K.
Road, Mumbai-400020 (v) Operations Manager SGS India Pvt, Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal (MP)-
462011. above (i) to (v) are requested to call for original INK-SIGNED Rate Contract For Verification to their full satisfaction including validity of various documents like Validity of Registration, BIS Registration etc. before taking action i.e. inspection of stores, as the responsibility rests with the concerned authority. For information and necessary action against Authorized Inspection Agency accorded by CSIDC for inspection of stores.
9. Incharge, Monitoring Cell, MKT-1 CSIDC, Ltd. Raipur for necessary action against inspection of stores . 10. Manager (Tender), Marketing Div., CSIDC Ltd., Raipur. He is requested to maintain a master file
of Rate Contract. 11. Computer cell, CSIDC Ltd., Raipur to release Rate Contract on CSIDC website.
12. Main file of Item- RCC HUME PIPE
(Suresh Keshi) General Manager
![Page 180: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/180.jpg)
No. 180/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/DCP/6481 Dated: 31-03-2015
SCHEDULE “A” Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per Annexure’A’ enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Dhansree Concrete Products , THE FIRM Manendragarh Road Ambikapur (C.G.) 497001
Mo.- 9425580211
(b) NAME AND FULL ADDRESS OF :- M/s Dhansree Concrete Products , MANUFACTURER Manendragarh Road Ambikapur (C.G.) 497001
Mo.- 9425580211 (C) Category :- General 2. VALIDITY OF RATE CONTRACT :- From 31-03-2015 To 01-04-2016 17. DESCRIPTION OF ITEM- RCC HUME PIPE SPECIFICATION, UNIT RATE AS BELOW
S.No. Item Code No. Item Description Class Rate ( )
E.D. VAT/CST Extra As Applicable
Rate Per Meter
Schedule -1: Reinforced Concrete, Light duty, Non-Pressure Pipes, Class: NP2, with ends of the Pipes suitable for collar joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
1 RCCHPF80001012 600 760.91 Schedule -3: Reinforced Concrete, Medium duty, Non-Pressure Pipes, Class: NP3, with ends of the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
2 RCCHPF80001052 450 1050.00 3 RCCHPF80001053 500 1155.00 4 RCCHPF80001054 600 1480.50 5 RCCHPF80001055 700 1680.00 6 RCCHPF80001056 800 2250.00 7 RCCHPF80001057 900 2936.38 8 RCCHPF80001058 1000 3052.39 9 RCCHPF80001059 1100 3465.00
10 RCCHPF80001060 1200 4378.50 11 RCCHPF80001061 1400 5911.43 12 RCCHPF80001062 1600 7045.31 13 RCCHPF80001063 1800 7793.75
Schedule -5: Reinforced Concrete, Heavy duty, Non-Pressure Pipes, Class: NP4, with ends of the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm. 14 RCCHPF80001094 450 1037.84 15 RCCHPF80001095 500 1239.91 16 RCCHPF80001096 600 1386.00 17 RCCHPF80001097 700 1732.50
(Suresh Keshi) General Manager
![Page 181: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/181.jpg)
No. 181/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/DCP/6481 Dated: 31-03-2015
18 RCCHPF80001098 800 1963.50 19 RCCHPF80001099 900 2772.00 20 RCCHPF80001100 1000 3291.75 21 RCCHPF80001102 1200 4389.00 22 RCCHPF80001103 1400 5313.00 23 RCCHPF80001104 1600 7507.50
Schedule -7: Reinforced Concrete Collar for Reinforced Concrete Light duty, Non-Pressure Pipes, Class: NP2, conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Reinforced Concrete Collar for the Pipes. Class: NP2, Size (Nominal Diameter in mm.) is as per below: 24 RCCHPF80001138 600 210.00
Schedule - 7 Transportation Charges : Sub Item Code No. Item Description Distance in Km. Transportation Charges in % on the Total Cost of Pipes/Collars.
E.D. VAT/CST Extra 25 RCCHPF80001148 Upto 50 Km. 19.64 26 RCCHPF80001149 Above 50 Km. Upto 100 Km. 21.00 27 RCCHPF80001150 Above 100 Km. Upto 150 Km. 28.88 28 RCCHPF80001151 Above 150 Km. Upto 200 Km. 32.00 29 RCCHPF80001152 Above 200 Km. 37.00
Note :- Technical particulars as per Annexure A enclosed 4. TERMS OF DELIVERY : F. O. R Destination (Any where in C.G.State) 5. EXCISE DUTY : Not Applicable 6. SALES TAX /VAT : Extra, as Applicable
TIN No. 22775003158 Address:-
M/s Dhansree Concrete Products , Manendragarh Road Ambikapur (C.G.) 497001 Mo.- 9425580211
7. DELIVERY PERIOD : 45 Days 8. a. ANNUAL TURN OVER/ : NM b. MONETARY LIMIT : Not Mentioned c. INSTALLED CAPACITY : (as per Ambikapur DTIC Registration Certificate) Description Capacity/Annum
RCC HUME PIPE 8000 Nos. 9. SLAB DISCOUNT (IF ANY) : Not Mentioned. 10. PRICES : Prices are Firm and Final 11. MINIMUM QUANTITY IN : Not Mentioned. SINGLE SUPPLY ORDER 12. STATUS OF RC HOLDING : SSI Unit
FIRM
(Suresh Keshi) General Manager
![Page 182: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/182.jpg)
No. 182/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/DCP/6481 Dated: 31-03-2015
13. REGISTRATION STATUS : Manufacturer is Registered with Ambikapur DTIC DTIC EM Part-II 220021100110 Dated 19-02-2008 14 BIS LICENSE : Not Mentioned 15. PAYING AUTHORITY : As Mentioned in supply order to be issued by Direct Demanding
Officers (DDOs). 16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each
consignment there-of will be made after receipt and acceptance of the stores by the consignee/interim consignee in full and good condition within 20 days as per SPR rule No.11, if the bills are in order. In case of delay in payment without any reason the department will be liable to pay interest as per prevailing bank rate. Bills are to be submitted in the prescribed form of the paying authority of purchaser / indenter and are to be supported with inspection note issued by the inspector and consignee’s Receipt Certificate .
17 INSPECTION AUTHORITY : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah) OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
18 QUALITY ASSURANCE : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah)
OR Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
(Suresh Keshi) General Manager
![Page 183: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/183.jpg)
No. 183/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/DCP/6481 Dated: 31-03-2015 19. PLACE WHERE THE STORES Manufacturer’s Factory at
ARE TO BE OFFERED FOR M/s Dhansree Concrete Products , INSPECTION Manendragarh Road Ambikapur (C.G.) 497001
Mo.- 9425580211
20 INSPECTION CHARGES : 0.60% Inspection charges + Service Tax As Applicable to be paid extra at the time of inspection to Quality Assurance Officer which will be billed by the unit along with bill of the material and will be reimbursed by the paying authority of DDO.
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause 7, the Purchaser / DDOs may require the contractor to furnish a security deposit which shall be made after issue of the acceptance of the supply order within the period specified by the purchaser / DDOs. Such security deposit shall not ordinarily exceed 3% . The security shall be in form of Demand Drafts issued by any of the Scheduled Commercial Banks. No other form of security is to be accepted. The security deposit amount is to be refunded after successful completion of the supply.
22. Special Note 1. Purchasing Departments / end user will ensure to sending the copy of every order to this office for Approval of inspection Agency against inspection of stores. 2. Purchasing Departments / end user will ensure to Pre
Dispatch inspection of stores Through inspection agency in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to obtained the central excise invoices of Manufacturer as mentioned in the Schedule-A vide sr. no. 1-B if excise duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to execute the Integrity Pact between BUYER and BIDDER/SUPPLIEY in accordance with the letter vide no. 799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi) General Manager
![Page 184: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/184.jpg)
No. 184/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/DCP/6481 Dated: 31-03-2015
Annexure 'A' CSIDC/MKD/TECH/2014-15/14
TECHNICAL PARTICULARS OF R.C.C. HUME PIPES
TSC 15-10-2014
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes (Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish / Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket & Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
The Pipes shall be of the following Sizes & Classification: Schedule- 1: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for collar joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment
Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment. 2. Tenderers may also quote rates separately for the Collars. Dimensions and Design requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003, with up-to-date amendment. Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 185: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/185.jpg)
No. 185/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/DCP/6481 Dated: 31-03-2015 Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment 2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment. Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
15. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 186: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/186.jpg)
No. 186/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/DCP/6481 Dated: 31-03-2015 Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter in mm) , is as per below: 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule - 8 Transportation Charges:
Sub Item Code No.
Item Description Distance in km. Transportation Charges in % on the Total Cost of Pipes/ Collars
1 Upto 50 km. 2 Above 50 km. upto 100 km. 3 Above 100 km. upto 150 km. 4 Above 150 km. upto 200 km. 5 Above 200 km.
Inspection & Testing: As per prevailing practice, the following Review of Reports shall be carried out. Review of Reports: The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review: During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively, if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the Inspecting Officer for review.
(K.N.K. Mishra) Incharge PS-VII
![Page 187: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/187.jpg)
No. 187/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/DCP/6481 Dated: 31-03-2015 1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes. 2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement. 3. Manufacture’s Test Repot of Rubber Rings shall be submitted for review (incase of Pipes with Socket & Spigot ends). TESTS: As per prevailing practice, the following Tests / Checking shall be carried out. 1. Visual examination, 2. Permeability Test and 3. Three Edge Bearing Test to produce 0.25 mm crack. 4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date amendment shall be carried out if desired by the Consignee. NOTE: 1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. The length in which the pipes are to be supplied shall be as per the mutual agreement between the purchaser and the supplier. However, the recommended length above 300 mm Nominal Diameter is 2.5 meters. 4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. 6. The following information shall be shall be clearly marked on the each Finished Pipe. a. Size of Pipe, b. Class of Pipe, and c. Name of manufacture. 7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of receipt of the materials by the consignee. 8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment towards the supply of Rubber rings will be made) as per the prevailing practice, transportation cost for Pipes & Collars shall be quoted separately.
Recommended by Technical Specification Committee Dated 15-10-2014
(K.N.K. Mishra) Incharge PS-VII
![Page 188: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/188.jpg)
No. 188/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/DCP/6481 Dated: 31-03-2015
SCHEDULE ‘B’ (SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi) General Manager
![Page 189: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/189.jpg)
No. 189/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/DCP/6481 Dated: 31-03-2015
SCHEDULE – “D”
FORMAT FOR QUATERLY DRAWAL REPORT
Name of the Firm __________________ I- Jan-Mar Report No. __________________ II- Apr-June Rate Contract No. __________________ III- July-Sept. Date of Submission __________________ IV- Oct - Dec Total Position of Order against Rate Contract till the submission of Report. S.No. Name of
Department Quantity and Value of Orders Received (Rs.)
Quantity and Value of Orders Executed (Rs.)
Balance Quantity and Value to be Supplied (Rs.)
Reasons
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all Taxes duties and incidental b) Value of orders supplied during the quarter-Rs. Charges
2. Nil report should also be Submitted.
(Suresh Keshi) General Manager
![Page 190: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/190.jpg)
No. 190/336 rS Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking) First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.) EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt) CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004 Website: www.csidc.in, Email : [email protected], [email protected]
No./CSIDC/MKD/ PS-VII /14-15/ Raipur, Dated :
Registered A/D Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/SI/6482 Dated: 31-03-2015 To,
M/s Shivshakti Industries, Kena Bandh Bouripara, Ambikapur, Distt Surguja (C.G.) 497001 Mo.-9425582023-24
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 31-03-2015 to 01-04-2016) Ref :- (I) This Office Tender Enquiry No. PS-VII/CSIDC/MKD/102/510/14-15
(II) Bid No. 8417 Dated 11-11-2014 (III) Your Offer acceptance alongwith undertaking submitted on dated 31-03-2015
Dear Sir, You are hereby informed that your above referred tender read with subsequent letters mentioned above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction. You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the time of getting the payment. SCHEDULES ANNEXED: 1. Schedule “A” Description of Stores, Prices, Duties/Taxes . 2. Annexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions of contract (if any). 4. Schedule “C” Information to DDOs about parallel rate contracts. 5. Schedule “D” Format for Drawal Report. Encl. 13 pages
Yours faithfully,
(Suresh Keshi) General Manager
For and on behalf of the purchaser Named in CSIDC Form No.2
![Page 191: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/191.jpg)
No. 191/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/SI/6482 Dated: 31-03-2015 Copy to, 1. The Secretary, Chhattisgarh Vidhan Sabha ,Raipur .
2. The Registrar, Honourable High court Chhattisgarh, Bilaspur .
3. The Accountant General Chhattisgarh State, Raipur.
4. All HODs of Chhattisgarh Govt. with a request to circulate the copy of R/C to all Direct Demanding Officers of your institution against issue of purchase order (Indent) in Favour of Rate Contract Holders of CSIDC.
5. All Collectors, Chhattisgarh State against issue of purchase order (Indent) in Favour of Rate Contract holders of CSIDC.
6. The Director Treasury, Chhattisgarh Govt., Raipur with a request to circulate copy of R/C to all branches under your control .
7. (i) Director of Public Instruction Department Pension Bada Raipur (ii) Engineer in Chief PHED C.G. Neer Bhawan, Raipur (iii) The Commissioner , Local Administrator , RDA Building Raipur (iv) Engineer in Chief PWD C.G.Civil lines Raipur .
Sr. No. 1 to 7 above are requested to call for original INK-SIGNED Rate Contract for verification to their full satisfaction including validity of various documents like Registration, Tax Registration etc. before taking action i.e. against issue of purchase order in Favour of Rate Contract holders of CSIDC, pre dispatched inspection of stores, acceptance of store.
8. (i) Dy.Director (Q.A.) , DGS&D, Bhilai, Durg (C.G.). (ii) Manager (Operation) Indian Register of Shipping, Senior MIG-2, Secter A, 1st Floor,
Infront of Bank of India Indrapuri Bhopal. (iii) Chief Engineer, PDIL, 4th floor, 4/2 Karaya Road, 67 Shekespeare Sarani, Kolkata (W.B.) (iv) General Manager (Inspection) RITES Ltd., Church gate Station Road, Second Floor, M.K.
Road, Mumbai-400020 (v) Operations Manager SGS India Pvt, Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal (MP)-
462011. above (i) to (v) are requested to call for original INK-SIGNED Rate Contract For Verification to their full satisfaction including validity of various documents like Validity of Registration, BIS Registration etc. before taking action i.e. inspection of stores, as the responsibility rests with the concerned authority. For information and necessary action against Authorized Inspection Agency accorded by CSIDC for inspection of stores.
9. Incharge, Monitoring Cell, MKT-1 CSIDC, Ltd. Raipur for necessary action against inspection of stores . 10. Manager (Tender), Marketing Div., CSIDC Ltd., Raipur. He is requested to maintain a master file
of Rate Contract. 11. Computer cell, CSIDC Ltd., Raipur to release Rate Contract on CSIDC website.
12. Main file of Item- RCC HUME PIPE
(Suresh Keshi) General Manager
![Page 192: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/192.jpg)
No. 192/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/SI/6482 Dated: 31-03-2015
SCHEDULE “A” Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per Annexure’A’ enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Shivshakti Industries, THE FIRM Kena Bandh Bouripara,
Ambikapur, Distt Surguja (C.G.) 497001 Mo.-9425582023-24
(b) NAME AND FULL ADDRESS OF :- M/s Shivshakti Industries, MANUFACTURER Kena Bandh Bouripara,
Ambikapur, Distt Surguja (C.G.) 497001 Mo.-9425582023-24
(C) Category :- General 2. VALIDITY OF RATE CONTRACT :- From 31-03-2015 To 01-04-2016 18. DESCRIPTION OF ITEM- RCC HUME PIPE SPECIFICATION, UNIT RATE AS BELOW
S.No. Item Code No. Item Description Class Rate ( )
E.D. VAT/CST Extra As Applicable
Rate Per Meter
Schedule -3: Reinforced Concrete, Medium duty, Non-Pressure Pipes, Class: NP3, with ends of the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
1 RCCHPF80001052 450 1050.00 2 RCCHPF80001054 600 1480.50 3 RCCHPF80001057 900 2936.38
4 RCCHPF80001058 1000 3052.39 5 RCCHPF80001060 1200 4378.50
Schedule -5: Reinforced Concrete, Heavy duty, Non-Pressure Pipes, Class: NP4, with ends of the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
6 RCCHPF80001099 900 2772.00 7 RCCHPF80001100 1000 3291.75 8 RCCHPF80001102 1200 4389.00
Schedule - 7 Transportation Charges : Sub Item Code No. Item Description Distance in Km. Transportation Charges in % on the Total Cost of Pipes/Collars.
E.D. VAT/CST Extra 9 RCCHPF80001148 Upto 50 Km. 19.64 10 RCCHPF80001149 Above 50 Km. Upto 100 Km. 21.00 11 RCCHPF80001150 Above 100 Km. Upto 150 Km. 28.88 12 RCCHPF80001151 Above 150 Km. Upto 200 Km. 32.00 13 RCCHPF80001152 Above 200 Km. 37.00
Note :- Technical particulars as per Annexure A enclosed 4. TERMS OF DELIVERY : F. O. R Destination (Any where in C.G.State)
(Suresh Keshi) General Manager
![Page 193: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/193.jpg)
No. 193/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/SI/6482 Dated: 31-03-2015 5. EXCISE DUTY : Not Applicable
6. SALES TAX /VAT : Extra, as Applicable
TIN No. 22595004130 Address:-
M/s Shivshakti Industries, Kena Bandh Bouripara, Ambikapur, Distt Surguja (C.G.) 497001 Mo.-9425582023-24
7. DELIVERY PERIOD : 45 Days 8. a. ANNUAL TURN OVER/ : NM b. MONETARY LIMIT : Not Mentioned c. INSTALLED CAPACITY : (as per Ambikapur DTIC Registration Certificate) Description Capacity/Annum
RCC HUME PIPE 9500 Nos. 9. SLAB DISCOUNT (IF ANY) : Not Mentioned. 10. PRICES : Prices are Firm and Final. 11. MINIMUM QUANTITY IN : Not Mentioned. SINGLE SUPPLY ORDER 12. STATUS OF RC HOLDING : SSI Unit
FIRM
13. REGISTRATION STATUS : Manufacturer is Registered with Ambikapur DTIC DTIC EM Part- II 220021100213 Dated 29-04-2009
14 BIS LICENSE : Not Mentioned
15. PAYING AUTHORITY : As Mentioned in supply order to be issued by Direct Demanding Officers (DDOs).
16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each consignment there-of will be made after receipt and acceptance of the stores by the consignee/interim consignee in full and good condition within 20 days as per SPR rule No.11, if the bills are in order. In case of delay in payment without any reason the department will be liable to pay interest as per prevailing bank rate. Bills are to be submitted in the prescribed form of the paying authority of purchaser / indenter and are to be supported with inspection note issued by the inspector and consignee’s Receipt Certificate .
17 INSPECTION AUTHORITY : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
(Suresh Keshi) General Manager
![Page 194: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/194.jpg)
No. 194/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/SI/6482 Dated: 31-03-2015
OR
Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah) OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
18 QUALITY ASSURANCE : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah) OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
19. PLACE WHERE THE STORES Manufacturer’s Factory at ARE TO BE OFFERED FOR M/s Shivshakti Industries, INSPECTION Kena Bandh Bouripara,
Ambikapur, Distt Surguja (C.G.) 497001 Mo.-9425582023-24
20 INSPECTION CHARGES : 0.60% Inspection charges + Service Tax As Applicable to be
paid extra at the time of inspection to Quality Assurance Officer which will be billed by the unit along with bill of the material and will be reimbursed by the paying authority of DDO.
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause 7, the Purchaser / DDOs may require the contractor to furnish a security deposit which shall be made after issue of the acceptance of the supply order within the period specified by the purchaser / DDOs. Such security deposit shall not ordinarily exceed 3% . The security shall be in form of Demand Drafts issued by any of the Scheduled Commercial Banks. No other form of security is to be accepted. The security deposit amount is to be refunded after successful completion of the supply.
(Suresh Keshi) General Manager
![Page 195: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/195.jpg)
No. 195/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/SI/6482 Dated: 31-03-2015
22. Special Note : 1. Purchasing Departments / end user will ensure to sending the copy of every order to this office for Approval of inspection Agency against inspection of stores.
2. Purchasing Departments / end user will ensure to Pre Dispatch inspection of stores Through inspection agency in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to obtained the central excise invoices of Manufacturer as mentioned in the Schedule-A vide sr. no. 1-B if excise duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to execute the Integrity Pact between BUYER and BIDDER/SUPPLIEY in accordance with the letter vide no. 799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi) General Manager
![Page 196: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/196.jpg)
No. 196/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/SI/6482 Dated: 31-03-2015
Annexure 'A' CSIDC/MKD/TECH/2014-15/14
TECHNICAL PARTICULARS OF R.C.C. HUME PIPES
TSC 15-10-2014
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes (Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish / Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket & Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
The Pipes shall be of the following Sizes & Classification: Schedule- 1: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for collar joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment
Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment. 2. Tenderers may also quote rates separately for the Collars. Dimensions and Design requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003, with up-to-date amendment. Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 197: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/197.jpg)
No. 197/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/SI/6482 Dated: 31-03-2015 Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment 2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment. Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
16. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 198: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/198.jpg)
No. 198/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/SI/6482 Dated: 31-03-2015 Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter in mm) , is as per below: 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule - 8 Transportation Charges:
Sub Item Code No.
Item Description Distance in km. Transportation Charges in % on the Total Cost of Pipes/ Collars
1 Upto 50 km. 2 Above 50 km. upto 100 km. 3 Above 100 km. upto 150 km. 4 Above 150 km. upto 200 km. 5 Above 200 km.
Inspection & Testing: As per prevailing practice, the following Review of Reports shall be carried out. Review of Reports: The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review: During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively, if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the Inspecting Officer for review.
(K.N.K. Mishra) Incharge PS-VII
![Page 199: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/199.jpg)
No. 199/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/SI/6482 Dated: 31-03-2015 1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes. 2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement. 3. Manufacture’s Test Repot of Rubber Rings shall be submitted for review (incase of Pipes with Socket & Spigot ends). TESTS: As per prevailing practice, the following Tests / Checking shall be carried out. 1. Visual examination, 2. Permeability Test and 3. Three Edge Bearing Test to produce 0.25 mm crack. 4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date amendment shall be carried out if desired by the Consignee. NOTE: 1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. The length in which the pipes are to be supplied shall be as per the mutual agreement between the purchaser and the supplier. However, the recommended length above 300 mm Nominal Diameter is 2.5 meters. 4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. 6. The following information shall be shall be clearly marked on the each Finished Pipe. a. Size of Pipe, b. Class of Pipe, and c. Name of manufacture. 7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of receipt of the materials by the consignee. 8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment towards the supply of Rubber rings will be made) as per the prevailing practice, transportation cost for Pipes & Collars shall be quoted separately.
Recommended by Technical Specification Committee Dated 15-10-2014
(K.N.K. Mishra) Incharge PS-VII
![Page 200: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/200.jpg)
No. 200/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/SI/6482 Dated: 31-03-2015
SCHEDULE ‘B’ (SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi) General Manager
![Page 201: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/201.jpg)
No. 201/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/SI/6482 Dated: 31-03-2015
SCHEDULE – “D”
FORMAT FOR QUATERLY DRAWAL REPORT
Name of the Firm __________________ I- Jan-Mar Report No. __________________ II- Apr-June Rate Contract No. __________________ III- July-Sept. Date of Submission __________________ IV- Oct - Dec Total Position of Order against Rate Contract till the submission of Report. S.No. Name of
Department Quantity and Value of Orders Received (Rs.)
Quantity and Value of Orders Executed (Rs.)
Balance Quantity and Value to be Supplied (Rs.)
Reasons
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all Taxes duties and incidental b) Value of orders supplied during the quarter-Rs. Charges
2. Nil report should also be Submitted.
(Suresh Keshi) General Manager
![Page 202: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/202.jpg)
No. 202/336 S Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking) First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.) EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt) CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004 Website: www.csidc.in, Email : [email protected], [email protected]
No./CSIDC/MKD/ PS-VII /15-16/ Raipur, Dated :
Registered A/D Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JMCPI/6483 Dated: 10-04-2015 To,
M/s Jai Mahamaya Cement Pipe Industries, Mission Chowk, Ring Road, Ambikapur Distt.- Surguja (C.G.) 497001 Mo.- 9826122358 Email- [email protected]
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 10-04-2015 to 01-04-2016) Ref :- (I) This Office Tender Enquiry No. PS-VII/CSIDC/MKD/102/510/15-16
(II) Bid No. 8432 Dated 18-11-2014 (III) Your Offer acceptance alongwith undertaking submitted on dated 27-03-2015
Dear Sir, You are hereby informed that your above referred tender read with subsequent letters mentioned above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction. You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the time of getting the payment. SCHEDULES ANNEXED: 1. Schedule “A” Description of Stores, Prices, Duties/Taxes . 2. Annexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions of contract (if any). 4. Schedule “C” Information to DDOs about parallel rate contracts. 5. Schedule “D” Format for Drawal Report. Encl. 14 pages
Yours faithfully,
(Suresh Keshi) General Manager
For and on behalf of the purchaser Named in CSIDC Form No.2
![Page 203: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/203.jpg)
No. 203/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JMCPI/6483 Dated: 10-04-2015 Copy to, 1. The Secretary, Chhattisgarh Vidhan Sabha ,Raipur .
2. The Registrar, Honourable High court Chhattisgarh, Bilaspur .
3. The Accountant General Chhattisgarh State, Raipur.
4. All HODs of Chhattisgarh Govt. with a request to circulate the copy of R/C to all Direct Demanding Officers of your institution against issue of purchase order (Indent) in Favour of Rate Contract Holders of CSIDC.
5. All Collectors, Chhattisgarh State against issue of purchase order (Indent) in Favour of Rate Contract holders of CSIDC.
6. The Director Treasury, Chhattisgarh Govt., Raipur with a request to circulate copy of R/C to all branches under your control .
7. (i) Director of Public Instruction Department Pension Bada Raipur (ii) Engineer in Chief PHED C.G. Neer Bhawan, Raipur (iii) The Commissioner , Local Administrator , RDA Building Raipur (iv) Engineer in Chief PWD C.G.Civil lines Raipur .
Sr. No. 1 to 7 above are requested to call for original INK-SIGNED Rate Contract for verification to their full satisfaction including validity of various documents like Registration, Tax Registration etc. before taking action i.e. against issue of purchase order in Favour of Rate Contract holders of CSIDC, pre dispatched inspection of stores, acceptance of store.
8. (i) Dy.Director (Q.A.) , DGS&D, Bhilai, Durg (C.G.). (ii) Manager (Operation) Indian Register of Shipping, Senior MIG-2, Secter A, 1st Floor,
Infront of Bank of India Indrapuri Bhopal. (iii) Chief Engineer, PDIL, 4th floor, 4/2 Karaya Road, 67 Shekespeare Sarani, Kolkata (W.B.) (iv) General Manager (Inspection) RITES Ltd., Church gate Station Road, Second Floor, M.K.
Road, Mumbai-400020 (v) Operations Manager SGS India Pvt, Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal (MP)-
462011. above (i) to (v) are requested to call for original INK-SIGNED Rate Contract For Verification to their full satisfaction including validity of various documents like Validity of Registration, BIS Registration etc. before taking action i.e. inspection of stores, as the responsibility rests with the concerned authority. For information and necessary action against Authorized Inspection Agency accorded by CSIDC for inspection of stores.
9. Incharge, Monitoring Cell, MKT-1 CSIDC, Ltd. Raipur for necessary action against inspection of stores . 10. Manager (Tender), Marketing Div., CSIDC Ltd., Raipur. He is requested to maintain a master file
of Rate Contract. 11. Computer cell, CSIDC Ltd., Raipur to release Rate Contract on CSIDC website.
12. Main file of Item- RCC HUME PIPE
(Suresh Keshi) General Manager
![Page 204: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/204.jpg)
No. 204/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JMCPI/6483 Dated: 10-04-2015
SCHEDULE “A” Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per Annexure’A’ enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Jai Mahamaya Cement Pipe Industries, THE FIRM Mission Chowk, Ring Road,
Ambikapur Distt.- Surguja (C.G.) 497001 Mo.- 9826122358 Email- [email protected]
(b) NAME AND FULL ADDRESS OF :- M/s Jai Mahamaya Cement Pipe Industries,
MANUFACTURER Mission Chowk, Ring Road, Ambikapur Distt.- Surguja (C.G.) 497001 Mo.- 9826122358 Email- [email protected]
(C) Category :- General 2. VALIDITY OF RATE CONTRACT :- From 10-04-2015 To 01-04-2016 19. DESCRIPTION OF ITEM- RCC HUME PIPE SPECIFICATION, UNIT RATE AS BELOW
S.No. Item Code No. Item Description Class Rate ( ) E.D. VAT/CST
Extra As Applicable Rate Per Meter
Schedule -1: Reinforced Concrete, Light duty, Non-Pressure Pipes, Class: NP2, with ends of the Pipes suitable for collar joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
1 RCCHPF80001012 600 760.91 2 RCCHPF80001014 800 1307.27 3 RCCHPF80001015 900 1155.00 4 RCCHPF80001016 1000 1212.75 5 RCCHPF80001018 1200 1501.50
Schedule -2: Reinforced Concrete, Light duty, Non-Pressure Pipes, Class: NP2, with ends of the Pipes Suitable for Socket & Spigot, roll & joints or confined gasket joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm.
6 RCCHPF80001024 150 42.11 7 RCCHPF80001025 200 51.98 8 RCCHPF80001028 300 76.23 9 RCCHPF80001031 450 140.33 10 RCCHPF80001033 600 217.14 11 RCCHPF80001035 800 243.71 12 RCCHPF80001036 900 360.94 13 RCCHPF80001037 1000 378.99 14 RCCHPF80001039 1200 706.86
(Suresh Keshi)
General Manager
![Page 205: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/205.jpg)
No. 205/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JMCPI/6483 Dated: 10-04-2015
Schedule -3: Reinforced Concrete, Medium duty, Non-Pressure Pipes, Class: NP3, with ends of the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
15 RCCHPF80001045 150 183.37 16 RCCHPF80001046 200 264.45 17 RCCHPF80001047 225 275.68 18 RCCHPF80001048 250 309.35 19 RCCHPF80001049 300 309.35 20 RCCHPF80001050 350 415.80 21 RCCHPF80001051 400 462.00 22 RCCHPF80001052 450 1050.00 23 RCCHPF80001053 500 1155.00 24 RCCHPF80001054 600 1480.50 25 RCCHPF80001055 700 1680.00 26 RCCHPF80001056 800 2250.00 27 RCCHPF80001057 900 2936.38 28 RCCHPF80001058 1000 3052.39 29 RCCHPF80001059 1100 3465.00 30 RCCHPF80001060 1200 4378.50 31 RCCHPF80001061 1400 5911.43 32 RCCHPF80001062 1600 7045.31 33 RCCHPF80001063 1800 7793.75
Schedule -5: Reinforced Concrete, Heavy duty, Non-Pressure Pipes, Class: NP4, with ends of the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
34 RCCHPF80001091 300 415.80 35 RCCHPF80001092 350 462.00 36 RCCHPF80001094 450 1037.84 37 RCCHPF80001096 600 1386.00 38 RCCHPF80001099 900 2772.00 39 RCCHPF80001100 1000 3291.75 40 RCCHPF80001102 1200 4389.00
Schedule - 7 Transportation Charges : Sub Item Code No. Item Description Distance in Km. Transportation Charges in % on the Total Cost of Pipes/Collars.
E.D. VAT/CST Extra 41 RCCHPF80001148 Upto 50 Km. 19.64 42 RCCHPF80001149 Above 50 Km. Upto 100 Km. 21.00 43 RCCHPF80001150 Above 100 Km. Upto 150 Km. 28.88 44 RCCHPF80001151 Above 150 Km. Upto 200 Km. 32.00 45 RCCHPF80001152 Above 200 Km. 37.00
Note :- Technical particulars as per Annexure A enclosed 4. TERMS OF DELIVERY : F. O. R Destination (Any where in C.G.State) 5. EXCISE DUTY : Not Applicable 6. SALES TAX /VAT : Extra, as Applicable
TIN No. 22715002803
(Suresh Keshi) General Manager
![Page 206: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/206.jpg)
No. 206/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JMCPI/6483 Dated: 10-04-2015
Address:-
M/s Jai Mahamaya Cement Pipe Industries, Mission Chowk, Ring Road, Ambikapur Distt.- Surguja (C.G.) 497001 Mo.- 9826122358 Email- [email protected]
7. DELIVERY PERIOD : 30 Days 8. a. ANNUAL TURN OVER/ : 2011-12 Rs. 12607225.00
2012-13 Rs. 13915642.00 2013-14 Rs. 18206139.00
b. MONETARY LIMIT : Not Mentioned c. INSTALLED CAPACITY : (as per Ambikapur DTIC Registration Certificate) Description Capacity/Annum
RCC HUME PIPE 6800 Nos. 9. SLAB DISCOUNT (IF ANY) : Not Mentioned. 10. PRICES : Prices are Firm and Final 11. MINIMUM QUANTITY IN : Not Mentioned. SINGLE SUPPLY ORDER 12. STATUS OF RC HOLDING : SSI Unit
FIRM 13. REGISTRATION STATUS : Manufacturer is Registered with Ambikapur DTIC DTIC EM Part- II 220021100117 Dated 25-02-2008
14 BIS LICENSE : Not Mentioned 15. PAYING AUTHORITY : As Mentioned in supply order to be issued by Direct Demanding
Officers (DDOs). 16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each
consignment there-of will be made after receipt and acceptance of the stores by the consignee/interim consignee in full and good condition within 20 days as per SPR rule No.11, if the bills are in order. In case of delay in payment without any reason the department will be liable to pay interest as per prevailing bank rate. Bills are to be submitted in the prescribed form of the paying authority of purchaser / indenter and are to be supported with inspection note issued by the inspector and consignee’s Receipt Certificate .
(Suresh Keshi)
General Manager
![Page 207: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/207.jpg)
No. 207/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JMCPI/6483 Dated: 10-04-2015 17 INSPECTION AUTHORITY : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah) OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
18 QUALITY ASSURANCE : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah)
OR Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
19. PLACE WHERE THE STORES Manufacturer’s Factory at
ARE TO BE OFFERED FOR M/s Jai Mahamaya Cement Pipe Industries, INSPECTION Mission Chowk, Ring Road,
Ambikapur Distt.- Surguja (C.G.) 497001 Mo.- 9826122358 Email- [email protected]
20 INSPECTION CHARGES : 0.60% Inspection charges + Service Tax As Applicable to be paid extra at the time of inspection to Quality Assurance Officer which will be billed by the unit along with bill of the material and will be reimbursed by the paying authority of DDO.
(Suresh Keshi) General Manager
![Page 208: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/208.jpg)
No. 208/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JMCPI/6483 Dated: 10-04-2015 21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause
7, the Purchaser / DDOs may require the contractor to furnish a security deposit which shall be made after issue of the acceptance of the supply order within the period specified by the purchaser / DDOs. Such security deposit shall not ordinarily exceed 3% . The security shall be in form of Demand Drafts issued by any of the Scheduled Commercial Banks. No other form of security is to be accepted. The security deposit amount is to be refunded after successful completion of the supply.
22. Special Note 1. Purchasing Departments / end user will ensure to sending the copy of every order to this office for Approval of inspection Agency against inspection of stores. 2. Purchasing Departments / end user will ensure to Pre
Dispatch inspection of stores Through inspection agency in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to obtained the central excise invoices of Manufacturer as mentioned in the Schedule-A vide sr. no. 1-B if excise duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to execute the Integrity Pact between BUYER and BIDDER/SUPPLIEY in accordance with the letter vide no. 799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi) General Manager
![Page 209: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/209.jpg)
No. 209/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JMCPI/6483 Dated: 10-04-2015
Annexure 'A' CSIDC/MKD/TECH/2014-15/14
TECHNICAL PARTICULARS OF R.C.C. HUME PIPES
TSC 15-10-2014
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes (Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish / Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket & Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
The Pipes shall be of the following Sizes & Classification: Schedule- 1: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for collar joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment
Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment. 2. Tenderers may also quote rates separately for the Collars. Dimensions and Design requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003, with up-to-date amendment. Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 210: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/210.jpg)
No. 210/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JMCPI/6483 Dated: 10-04-2015 Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment 2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment. Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
17. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 211: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/211.jpg)
No. 211/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JMCPI/6483 Dated: 10-04-2015 Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter in mm) , is as per below: 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule - 8 Transportation Charges:
Sub Item Code No.
Item Description Distance in km. Transportation Charges in % on the Total Cost of Pipes/ Collars
1 Upto 50 km. 2 Above 50 km. upto 100 km. 3 Above 100 km. upto 150 km. 4 Above 150 km. upto 200 km. 5 Above 200 km.
Inspection & Testing: As per prevailing practice, the following Review of Reports shall be carried out. Review of Reports: The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review: During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively, if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the Inspecting Officer for review.
(K.N.K. Mishra) Incharge PS-VII
![Page 212: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/212.jpg)
No. 212/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JMCPI/6483 Dated: 10-04-2015 1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes. 2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement. 3. Manufacture’s Test Repot of Rubber Rings shall be submitted for review (incase of Pipes with Socket & Spigot ends). TESTS: As per prevailing practice, the following Tests / Checking shall be carried out. 1. Visual examination, 2. Permeability Test and 3. Three Edge Bearing Test to produce 0.25 mm crack. 4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date amendment shall be carried out if desired by the Consignee. NOTE: 1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. The length in which the pipes are to be supplied shall be as per the mutual agreement between the purchaser and the supplier. However, the recommended length above 300 mm Nominal Diameter is 2.5 meters. 4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. 6. The following information shall be shall be clearly marked on the each Finished Pipe. a. Size of Pipe, b. Class of Pipe, and c. Name of manufacture. 7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of receipt of the materials by the consignee. 8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment towards the supply of Rubber rings will be made) as per the prevailing practice, transportation cost for Pipes & Collars shall be quoted separately.
Recommended by Technical Specification Committee Dated 15-10-2014
(K.N.K. Mishra) Incharge PS-VII
![Page 213: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/213.jpg)
No. 213/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JMCPI/6483 Dated: 10-04-2015
SCHEDULE ‘B’ (SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi) General Manager
![Page 214: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/214.jpg)
No. 214/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JMCPI/6483 Dated: 10-04-2015
SCHEDULE – “D”
FORMAT FOR QUATERLY DRAWAL REPORT
Name of the Firm __________________ I- Jan-Mar Report No. __________________ II- Apr-June Rate Contract No. __________________ III- July-Sept. Date of Submission __________________ IV- Oct - Dec Total Position of Order against Rate Contract till the submission of Report. S.No. Name of
Department Quantity and Value of Orders Received (Rs.)
Quantity and Value of Orders Executed (Rs.)
Balance Quantity and Value to be Supplied (Rs.)
Reasons
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all Taxes duties and incidental b) Value of orders supplied during the quarter-Rs. Charges
2. Nil report should also be Submitted.
(Suresh Keshi) General Manager
![Page 215: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/215.jpg)
No. 215/336 S Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking) First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.) EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt) CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004 Website: www.csidc.in, Email : [email protected], [email protected]
No./CSIDC/MKD/ PS-VII /15-16/ Raipur, Dated :
Registered A/D Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JACP/6484 Dated: 10-04-2015 To,
M/s Jai Ambe Cement Product, Vill-Sargawan, Teh.-Ambikapur Distt.- Surguja (C.G.) 497001 Mo.- 9826122358, 9425254259
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 10-04-2015 to 01-04-2016) Ref :- (I) This Office Tender Enquiry No. PS-VII/CSIDC/MKD/102/510/15-16
(II) Bid No. 8431 Dated 18-11-2014 (III) Your Offer acceptance alongwith undertaking submitted on dated 27-03-2015
Dear Sir, You are hereby informed that your above referred tender read with subsequent letters mentioned above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction. You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the time of getting the payment. SCHEDULES ANNEXED: 1. Schedule “A” Description of Stores, Prices, Duties/Taxes . 2. Annexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions of contract (if any). 4. Schedule “C” Information to DDOs about parallel rate contracts. 5. Schedule “D” Format for Drawal Report. Encl. 14 pages
Yours faithfully,
(Suresh Keshi) General Manager
For and on behalf of the purchaser Named in CSIDC Form No.2
![Page 216: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/216.jpg)
No. 216/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JACP/6484 Dated: 10-04-2015 Copy to, 1. The Secretary, Chhattisgarh Vidhan Sabha ,Raipur .
2. The Registrar, Honourable High court Chhattisgarh, Bilaspur .
3. The Accountant General Chhattisgarh State, Raipur.
4. All HODs of Chhattisgarh Govt. with a request to circulate the copy of R/C to all Direct Demanding Officers of your institution against issue of purchase order (Indent) in Favour of Rate Contract Holders of CSIDC.
5. All Collectors, Chhattisgarh State against issue of purchase order (Indent) in Favour of Rate Contract holders of CSIDC.
6. The Director Treasury, Chhattisgarh Govt., Raipur with a request to circulate copy of R/C to all branches under your control .
7. (i) Director of Public Instruction Department Pension Bada Raipur (ii) Engineer in Chief PHED C.G. Neer Bhawan, Raipur (iii) The Commissioner , Local Administrator , RDA Building Raipur (iv) Engineer in Chief PWD C.G.Civil lines Raipur .
Sr. No. 1 to 7 above are requested to call for original INK-SIGNED Rate Contract for verification to their full satisfaction including validity of various documents like Registration, Tax Registration etc. before taking action i.e. against issue of purchase order in Favour of Rate Contract holders of CSIDC, pre dispatched inspection of stores, acceptance of store.
8. (i) Dy.Director (Q.A.) , DGS&D, Bhilai, Durg (C.G.). (ii) Manager (Operation) Indian Register of Shipping, Senior MIG-2, Secter A, 1st Floor,
Infront of Bank of India Indrapuri Bhopal. (iii) Chief Engineer, PDIL, 4th floor, 4/2 Karaya Road, 67 Shekespeare Sarani, Kolkata (W.B.) (iv) General Manager (Inspection) RITES Ltd., Church gate Station Road, Second Floor, M.K.
Road, Mumbai-400020 (v) Operations Manager SGS India Pvt, Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal (MP)-
462011. above (i) to (v) are requested to call for original INK-SIGNED Rate Contract For Verification to their full satisfaction including validity of various documents like Validity of Registration, BIS Registration etc. before taking action i.e. inspection of stores, as the responsibility rests with the concerned authority. For information and necessary action against Authorized Inspection Agency accorded by CSIDC for inspection of stores.
9. Incharge, Monitoring Cell, MKT-1 CSIDC, Ltd. Raipur for necessary action against inspection of stores . 10. Manager (Tender), Marketing Div., CSIDC Ltd., Raipur. He is requested to maintain a master file
of Rate Contract. 11. Computer cell, CSIDC Ltd., Raipur to release Rate Contract on CSIDC website.
12. Main file of Item- RCC HUME PIPE
(Suresh Keshi) General Manager
![Page 217: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/217.jpg)
No. 217/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JACP/6484 Dated: 10-04-2015
SCHEDULE “A” Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per Annexure’A’ enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Jai Ambe Cement Product, THE FIRM Vill-Sargawan, Teh.-Ambikapur
Distt.- Surguja (C.G.) 497001 Mo.- 9826122358, 9425254259
(b) NAME AND FULL ADDRESS OF :- M/s Jai Ambe Cement Product, MANUFACTURER Vill-Sargawan, Teh.-Ambikapur
Distt.- Surguja (C.G.) 497001 Mo.- 9826122358, 9425254259
(C) Category :- General 2. VALIDITY OF RATE CONTRACT :- From 10-04-2015 To 01-04-2016 20. DESCRIPTION OF ITEM- RCC HUME PIPE SPECIFICATION, UNIT RATE AS BELOW
S.No. Item Code No. Item Description Class Rate ( )
E.D. VAT/CST Extra As Applicable
Rate Per Meter
Schedule -1: Reinforced Concrete, Light duty, Non-Pressure Pipes, Class: NP2, with ends of the Pipes suitable for collar joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
1 RCCHPF80001012 600 760.91 2 RCCHPF80001014 800 1307.27 3 RCCHPF80001015 900 1155.00 4 RCCHPF80001016 1000 1212.75 5 RCCHPF80001018 1200 1501.50
Schedule -2: Reinforced Concrete, Light duty, Non-Pressure Pipes, Class: NP2, with ends of the Pipes Suitable for Socket & Spigot, roll & joints or confined gasket joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm.
6 RCCHPF80001024 150 42.11 7 RCCHPF80001025 200 51.98 8 RCCHPF80001028 300 76.23 9 RCCHPF80001031 450 140.33 10 RCCHPF80001033 600 217.14 11 RCCHPF80001035 800 243.71 12 RCCHPF80001036 900 360.94 13 RCCHPF80001037 1000 378.99 14 RCCHPF80001039 1200 706.86
Schedule -3: Reinforced Concrete, Medium duty, Non-Pressure Pipes, Class: NP3, with ends of the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
15 RCCHPF80001045 150 183.37
(Suresh Keshi) General Manager
![Page 218: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/218.jpg)
No. 218/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JACP/6484 Dated: 10-04-2015
16 RCCHPF80001046 200 264.45 17 RCCHPF80001047 225 275.68 18 RCCHPF80001048 250 309.35 19 RCCHPF80001049 300 309.35 20 RCCHPF80001050 350 415.80 21 RCCHPF80001051 400 462.00 22 RCCHPF80001052 450 1050.00 23 RCCHPF80001053 500 1155.00 24 RCCHPF80001054 600 1480.50 25 RCCHPF80001055 700 1680.00 26 RCCHPF80001056 800 2250.00 27 RCCHPF80001057 900 2936.38 28 RCCHPF80001058 1000 3052.39 29 RCCHPF80001059 1100 3465.00 30 RCCHPF80001060 1200 4378.50 31 RCCHPF80001061 1400 5911.43 32 RCCHPF80001062 1600 7045.31 33 RCCHPF80001063 1800 7793.75
Schedule -5: Reinforced Concrete, Heavy duty, Non-Pressure Pipes, Class: NP4, with ends of the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
34 RCCHPF80001091 300 415.80 35 RCCHPF80001092 350 462.00 36 RCCHPF80001094 450 1037.84 37 RCCHPF80001096 600 1386.00 38 RCCHPF80001099 900 2772.00 39 RCCHPF80001100 1000 3291.75 40 RCCHPF80001102 1200 4389.00
Schedule - 7 Transportation Charges : Sub Item Code No. Item Description Distance in Km. Transportation Charges in % on the Total Cost of Pipes/Collars.
E.D. VAT/CST Extra 41 RCCHPF80001148 Upto 50 Km. 19.64 42 RCCHPF80001149 Above 50 Km. Upto 100 Km. 21.00 43 RCCHPF80001150 Above 100 Km. Upto 150 Km. 28.88 44 RCCHPF80001151 Above 150 Km. Upto 200 Km. 32.00 45 RCCHPF80001152 Above 200 Km. 37.00
Note :- Technical particulars as per Annexure A enclosed 4. TERMS OF DELIVERY : F. O. R Destination (Any where in C.G.State) 5. EXCISE DUTY : Not Applicable 6. SALES TAX /VAT : Extra, as Applicable
TIN No. 22935003167 Address:-
M/s Jai Ambe Cement Product, Vill-Sargawan, Teh.-Ambikapur Distt.- Surguja (C.G.) 497001 Mo.- 9826122358, 9425254259
(Suresh Keshi)
General Manager
![Page 219: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/219.jpg)
No. 219/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JACP/6484 Dated: 10-04-2015 7. DELIVERY PERIOD : 30 Days 8. a. ANNUAL TURN OVER/ : 2011-12 Rs. 12310958.00
2012-13 Rs. 10787348.00 2013-14 Rs. 13846409.00
b. MONETARY LIMIT : Not Mentioned c. INSTALLED CAPACITY : (as per Ambikapur DTIC Registration Certificate) Description Capacity/Annum
RCC HUME PIPE 15,000 Nos.
9. SLAB DISCOUNT (IF ANY) : Not Mentioned. 10. PRICES : Prices are Firm and Final 11. MINIMUM QUANTITY IN : Not Mentioned. SINGLE SUPPLY ORDER 12. STATUS OF RC HOLDING : Manufacturer
FIRM
13. REGISTRATION STATUS : Manufacturer is Registered with Ambikapur DTIC DTIC EM Part- II 220021100116 Dated 25-02-2008
14 BIS LICENSE : Not Mentioned
15. PAYING AUTHORITY : As Mentioned in supply order to be issued by Direct Demanding Officers (DDOs).
16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each consignment there-of will be made after receipt and acceptance of the stores by the consignee/interim consignee in full and good condition within 20 days as per SPR rule No.11, if the bills are in order. In case of delay in payment without any reason the department will be liable to pay interest as per prevailing bank rate. Bills are to be submitted in the prescribed form of the paying authority of purchaser / indenter and are to be supported with inspection note issued by the inspector and consignee’s Receipt Certificate .
17 INSPECTION AUTHORITY : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah)
(Suresh Keshi) General Manager
![Page 220: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/220.jpg)
No. 220/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JACP/6484 Dated: 10-04-2015 OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING) 18 QUALITY ASSURANCE : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah)
OR Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
19. PLACE WHERE THE STORES Manufacturer’s Factory at ARE TO BE OFFERED FOR M/s Jai Ambe Cement Product, INSPECTION Vill-Sargawan, Teh.-Ambikapur
Distt.- Surguja (C.G.) 497001 Mo.- 9826122358, 9425254259
20 INSPECTION CHARGES : 0.60% Inspection charges + Service Tax As Applicable to be paid extra at the time of inspection to Quality Assurance Officer which will be billed by the unit along with bill of the material and will be reimbursed by the paying authority of DDO.
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause 7, the Purchaser / DDOs may require the contractor to furnish a security deposit which shall be made after issue of the acceptance of the supply order within the period specified by the purchaser / DDOs. Such security deposit shall not ordinarily exceed 3% . The security shall be in form of Demand Drafts issued by any of the Scheduled Commercial Banks. No other form of security is to be accepted. The security deposit amount is to be refunded after successful completion of the supply.
(Suresh Keshi) General Manager
![Page 221: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/221.jpg)
No. 221/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JACP/6484 Dated: 10-04-2015
22. Special Note 1. Purchasing Departments / end user will ensure to sending the copy of every order to this office for Approval of inspection Agency against inspection of stores. 2. Purchasing Departments / end user will ensure to Pre
Dispatch inspection of stores Through inspection agency in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to obtained the central excise invoices of Manufacturer as mentioned in the Schedule-A vide sr. no. 1-B if excise duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to execute the Integrity Pact between BUYER and BIDDER/SUPPLIEY in accordance with the letter vide no. 799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi) General Manager
![Page 222: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/222.jpg)
No. 222/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JACP/6484 Dated: 10-04-2015
Annexure 'A' CSIDC/MKD/TECH/2014-15/14
TECHNICAL PARTICULARS OF R.C.C. HUME PIPES
TSC 15-10-2014
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes (Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish / Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket & Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
The Pipes shall be of the following Sizes & Classification: Schedule- 1: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for collar joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment
Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment. 2. Tenderers may also quote rates separately for the Collars. Dimensions and Design requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003, with up-to-date amendment. Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 223: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/223.jpg)
No. 223/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JACP/6484 Dated: 10-04-2015 Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment 2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment. Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
18. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 224: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/224.jpg)
No. 224/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JACP/6484 Dated: 10-04-2015 Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter in mm) , is as per below: 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule - 8 Transportation Charges:
Sub Item Code No.
Item Description Distance in km. Transportation Charges in % on the Total Cost of Pipes/ Collars
1 Upto 50 km. 2 Above 50 km. upto 100 km. 3 Above 100 km. upto 150 km. 4 Above 150 km. upto 200 km. 5 Above 200 km.
Inspection & Testing: As per prevailing practice, the following Review of Reports shall be carried out. Review of Reports: The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review: During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively, if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the Inspecting Officer for review.
(K.N.K. Mishra) Incharge PS-VII
![Page 225: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/225.jpg)
No. 225/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JACP/6484 Dated: 10-04-2015 1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes. 2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement. 3. Manufacture’s Test Repot of Rubber Rings shall be submitted for review (incase of Pipes with Socket & Spigot ends). TESTS: As per prevailing practice, the following Tests / Checking shall be carried out. 1. Visual examination, 2. Permeability Test and 3. Three Edge Bearing Test to produce 0.25 mm crack. 4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date amendment shall be carried out if desired by the Consignee. NOTE: 1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. The length in which the pipes are to be supplied shall be as per the mutual agreement between the purchaser and the supplier. However, the recommended length above 300 mm Nominal Diameter is 2.5 meters. 4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. 6. The following information shall be shall be clearly marked on the each Finished Pipe. a. Size of Pipe, b. Class of Pipe, and c. Name of manufacture. 7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of receipt of the materials by the consignee. 8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment towards the supply of Rubber rings will be made) as per the prevailing practice, transportation cost for Pipes & Collars shall be quoted separately.
Recommended by Technical Specification Committee Dated 15-10-2014
(K.N.K. Mishra) Incharge PS-VII
![Page 226: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/226.jpg)
No. 226/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JACP/6484 Dated: 10-04-2015
SCHEDULE ‘B’ (SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi) General Manager
![Page 227: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/227.jpg)
No. 227/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JACP/6484 Dated: 10-04-2015
SCHEDULE – “D”
FORMAT FOR QUATERLY DRAWAL REPORT
Name of the Firm __________________ I- Jan-Mar Report No. __________________ II- Apr-June Rate Contract No. __________________ III- July-Sept. Date of Submission __________________ IV- Oct - Dec Total Position of Order against Rate Contract till the submission of Report. S.No. Name of
Department Quantity and Value of Orders Received (Rs.)
Quantity and Value of Orders Executed (Rs.)
Balance Quantity and Value to be Supplied (Rs.)
Reasons
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all Taxes duties and incidental b) Value of orders supplied during the quarter-Rs. Charges
2. Nil report should also be Submitted.
(Suresh Keshi) General Manager
![Page 228: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/228.jpg)
No. 228/336 S Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking) First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.) EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt) CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004 Website: www.csidc.in, Email : [email protected], [email protected]
No./CSIDC/MKD/ PS-VII /15-16/ Raipur, Dated :
Registered A/D Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JCP/6485 Dated: 10-04-2015 To,
M/s Jaiswal Cement Products, Mission Chowk, Ring Road, Ambikapur Distt.- Surguja (C.G.) 497001 Mo.- 9826122358 / 9425254259 Email- [email protected]
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 10-04-2015 to 01-04-2016) Ref :- (I) This Office Tender Enquiry No. PS-VII/CSIDC/MKD/102/510/15-16
(II) Bid No. 8433 Dated 18-11-2014 (III) Your Offer acceptance alongwith undertaking submitted on dated 27-03-2015
Dear Sir, You are hereby informed that your above referred tender read with subsequent letters mentioned above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction. You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the time of getting the payment. SCHEDULES ANNEXED: 1. Schedule “A” Description of Stores, Prices, Duties/Taxes . 2. Annexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions of contract (if any). 4. Schedule “C” Information to DDOs about parallel rate contracts. 5. Schedule “D” Format for Drawal Report. Encl. 14 pages
Yours faithfully,
(Suresh Keshi) General Manager
For and on behalf of the purchaser Named in CSIDC Form No.2
![Page 229: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/229.jpg)
No. 229/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JCP/6485 Dated: 10-04-2015 Copy to, 1. The Secretary, Chhattisgarh Vidhan Sabha ,Raipur .
2. The Registrar, Honourable High court Chhattisgarh, Bilaspur .
3. The Accountant General Chhattisgarh State, Raipur.
4. All HODs of Chhattisgarh Govt. with a request to circulate the copy of R/C to all Direct Demanding Officers of your institution against issue of purchase order (Indent) in Favour of Rate Contract Holders of CSIDC.
5. All Collectors, Chhattisgarh State against issue of purchase order (Indent) in Favour of Rate Contract holders of CSIDC.
6. The Director Treasury, Chhattisgarh Govt., Raipur with a request to circulate copy of R/C to all branches under your control .
7. (i) Director of Public Instruction Department Pension Bada Raipur (ii) Engineer in Chief PHED C.G. Neer Bhawan, Raipur (iii) The Commissioner , Local Administrator , RDA Building Raipur (iv) Engineer in Chief PWD C.G.Civil lines Raipur .
Sr. No. 1 to 7 above are requested to call for original INK-SIGNED Rate Contract for verification to their full satisfaction including validity of various documents like Registration, Tax Registration etc. before taking action i.e. against issue of purchase order in Favour of Rate Contract holders of CSIDC, pre dispatched inspection of stores, acceptance of store.
8. (i) Dy.Director (Q.A.) , DGS&D, Bhilai, Durg (C.G.). (ii) Manager (Operation) Indian Register of Shipping, Senior MIG-2, Secter A, 1st Floor,
Infront of Bank of India Indrapuri Bhopal. (iii) Chief Engineer, PDIL, 4th floor, 4/2 Karaya Road, 67 Shekespeare Sarani, Kolkata (W.B.) (iv) General Manager (Inspection) RITES Ltd., Church gate Station Road, Second Floor, M.K.
Road, Mumbai-400020 (v) Operations Manager SGS India Pvt, Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal (MP)-
462011. above (i) to (v) are requested to call for original INK-SIGNED Rate Contract For Verification to their full satisfaction including validity of various documents like Validity of Registration, BIS Registration etc. before taking action i.e. inspection of stores, as the responsibility rests with the concerned authority. For information and necessary action against Authorized Inspection Agency accorded by CSIDC for inspection of stores.
9. Incharge, Monitoring Cell, MKT-1 CSIDC, Ltd. Raipur for necessary action against inspection of stores . 10. Manager (Tender), Marketing Div., CSIDC Ltd., Raipur. He is requested to maintain a master file
of Rate Contract. 11. Computer cell, CSIDC Ltd., Raipur to release Rate Contract on CSIDC website.
12. Main file of Item- RCC HUME PIPE
(Suresh Keshi) General Manager
![Page 230: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/230.jpg)
No. 230/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JCP/6485 Dated: 10-04-2015
SCHEDULE “A” Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per Annexure’A’ enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Jaiswal Cement Products, THE FIRM Mission Chowk, Ring Road,
Ambikapur Distt.- Surguja (C.G.) 497001 Mo.- 9826122358 / 9425254259 Email- [email protected]
(b) NAME AND FULL ADDRESS OF :- M/s Jaiswal Cement Products,
MANUFACTURER Mission Chowk, Ring Road, Ambikapur Distt.- Surguja (C.G.) 497001 Mo.- 9826122358 / 9425254259 Email- [email protected]
(C) Category :- General 2. VALIDITY OF RATE CONTRACT :- From 10-04-2015 To 01-04-2016 21. DESCRIPTION OF ITEM- RCC HUME PIPE SPECIFICATION, UNIT RATE AS BELOW
S.No. Item Code No. Item Description Class Rate ( )
E.D. VAT/CST Extra As Applicable
Rate Per Meter
Schedule -1: Reinforced Concrete, Light duty, Non-Pressure Pipes, Class: NP2, with ends of the Pipes suitable for collar joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
1 RCCHPF80001012 600 760.91 2 RCCHPF80001014 800 1307.27 3 RCCHPF80001015 900 1155.00 4 RCCHPF80001016 1000 1212.75 5 RCCHPF80001018 1200 1501.50
Schedule -2: Reinforced Concrete, Light duty, Non-Pressure Pipes, Class: NP2, with ends of the Pipes Suitable for Socket & Spigot, roll & joints or confined gasket joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm.
6 RCCHPF80001024 150 42.11 7 RCCHPF80001025 200 51.98 8 RCCHPF80001028 300 76.23 9 RCCHPF80001031 450 140.33
10 RCCHPF80001033 600 217.14 11 RCCHPF80001035 800 243.71 12 RCCHPF80001036 900 360.94 13 RCCHPF80001037 1000 378.99 14 RCCHPF80001039 1200 706.86
(Suresh Keshi) General Manager
![Page 231: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/231.jpg)
No. 231/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JCP/6485 Dated: 10-04-2015
Schedule -3: Reinforced Concrete, Medium duty, Non-Pressure Pipes, Class: NP3, with ends of the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm. 15 RCCHPF80001045 150 183.37 16 RCCHPF80001046 200 264.45 17 RCCHPF80001047 225 275.68 18 RCCHPF80001048 250 309.35 19 RCCHPF80001049 300 309.35 20 RCCHPF80001050 350 415.80 21 RCCHPF80001051 400 462.00 22 RCCHPF80001052 450 1050.00 23 RCCHPF80001053 500 1155.00 24 RCCHPF80001054 600 1480.50 25 RCCHPF80001055 700 1680.00 26 RCCHPF80001056 800 2250.00 27 RCCHPF80001057 900 2936.38 28 RCCHPF80001058 1000 3052.39 29 RCCHPF80001059 1100 3465.00 30 RCCHPF80001060 1200 4378.50 31 RCCHPF80001061 1400 5911.43 32 RCCHPF80001062 1600 7045.31 33 RCCHPF80001063 1800 7793.75
Schedule -5: Reinforced Concrete, Heavy duty, Non-Pressure Pipes, Class: NP4, with ends of the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm. 34 RCCHPF80001091 300 415.80 35 RCCHPF80001092 350 462.00 36 RCCHPF80001094 450 1037.84 37 RCCHPF80001096 600 1386.00 38 RCCHPF80001099 900 2772.00 39 RCCHPF80001100 1000 3291.75 40 RCCHPF80001102 1200 4389.00
Schedule - 7 Transportation Charges : Sub Item Code No. Item Description Distance in Km. Transportation Charges in % on the Total Cost of Pipes/Collars.
E.D. VAT/CST Extra 41 RCCHPF80001148 Upto 50 Km. 19.64 42 RCCHPF80001149 Above 50 Km. Upto 100 Km. 21.00 43 RCCHPF80001150 Above 100 Km. Upto 150 Km. 28.88 44 RCCHPF80001151 Above 150 Km. Upto 200 Km. 32.00 45 RCCHPF80001152 Above 200 Km. 37.00
Note :- Technical particulars as per Annexure A enclosed 4. TERMS OF DELIVERY : F. O. R Destination (Any where in C.G.State) 5. EXCISE DUTY : Not Applicable 6. SALES TAX /VAT : Extra, as Applicable
TIN No. 22365001201
(Suresh Keshi) General Manager
![Page 232: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/232.jpg)
No. 232/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JCP/6485 Dated: 10-04-2015
Address:-
M/s Jaiswal Cement Products, Mission Chowk, Ring Road, Ambikapur Distt.- Surguja (C.G.) 497001 Mo.- 9826122358 / 9425254259 Email- [email protected]
7. DELIVERY PERIOD : 30 Days 8. a. ANNUAL TURN OVER/ : 2011-12 Rs. 14272462.00
2012-13 Rs. 11775619.00 2013-14 Rs. 14008858.00
b. MONETARY LIMIT : Not Mentioned c. INSTALLED CAPACITY : (as per Ambikapur DTIC Registration Certificate) Description Capacity/Annum
RCC HUME PIPE 7200 Nos. 9. SLAB DISCOUNT (IF ANY) : Not Mentioned. 10. PRICES : Prices are Firm and Final 11. MINIMUM QUANTITY IN : Not Mentioned. SINGLE SUPPLY ORDER 12. STATUS OF RC HOLDING : SSI Unit
FIRM
13. REGISTRATION STATUS : Manufacturer is Registered with Ambikapur DTIC DTIC EM Part- II 220021100115 Dated 25-02-2008
14 BIS LICENSE : Not Mentioned 15. PAYING AUTHORITY : As Mentioned in supply order to be issued by Direct Demanding
Officers (DDOs).
16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each consignment there-of will be made after receipt and acceptance of the stores by the consignee/interim consignee in full and good condition within 20 days as per SPR rule No.11, if the bills are in order. In case of delay in payment without any reason the department will be liable to pay interest as per prevailing bank rate. Bills are to be submitted in the prescribed form of the paying authority of purchaser / indenter and are to be supported with inspection note issued by the inspector and consignee’s Receipt Certificate .
(Suresh Keshi)
General Manager
![Page 233: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/233.jpg)
No. 233/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JCP/6485 Dated: 10-04-2015
17 INSPECTION AUTHORITY : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah) OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
18 QUALITY ASSURANCE : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah)
OR Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
19. PLACE WHERE THE STORES : Manufacturer’s Factory at ARE TO BE OFFERED FOR M/s Jaiswal Cement Products, INSPECTION Mission Chowk, Ring Road,
Ambikapur Distt.- Surguja (C.G.) 497001 Mo.- 9826122358 / 9425254259 Email- [email protected]
20 INSPECTION CHARGES : 0.60% Inspection charges + Service Tax As Applicable to be paid extra at the time of inspection to Quality Assurance Officer which will be billed by the unit along with bill of the material and will be reimbursed by the paying authority of DDO.
(Suresh Keshi)
General Manager
![Page 234: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/234.jpg)
No. 234/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JCP/6485 Dated: 10-04-2015
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause
7, the Purchaser / DDOs may require the contractor to furnish a security deposit which shall be made after issue of the acceptance of the supply order within the period specified by the purchaser / DDOs. Such security deposit shall not ordinarily exceed 3% . The security shall be in form of Demand Drafts issued by any of the Scheduled Commercial Banks. No other form of security is to be accepted. The security deposit amount is to be refunded after successful completion of the supply.
22. Special Note 1. Purchasing Departments / end user will ensure to sending the copy of every order to this office for Approval of inspection Agency against inspection of stores. 2. Purchasing Departments / end user will ensure to Pre
Dispatch inspection of stores Through inspection agency in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to obtained the central excise invoices of Manufacturer as mentioned in the Schedule-A vide sr. no. 1-B if excise duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to execute the Integrity Pact between BUYER and BIDDER/SUPPLIEY in accordance with the letter vide no. 799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi) General Manager
![Page 235: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/235.jpg)
No. 235/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JCP/6485 Dated: 10-04-2015
Annexure 'A' CSIDC/MKD/TECH/2014-15/14
TECHNICAL PARTICULARS OF R.C.C. HUME PIPES
TSC 15-10-2014
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes (Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish / Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket & Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
The Pipes shall be of the following Sizes & Classification: Schedule- 1: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for collar joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment
Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment. 2. Tenderers may also quote rates separately for the Collars. Dimensions and Design requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003, with up-to-date amendment. Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 236: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/236.jpg)
No. 236/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JCP/6485 Dated: 10-04-2015 Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment 2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment. Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
19. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 237: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/237.jpg)
No. 237/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JCP/6485 Dated: 10-04-2015 Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter in mm) , is as per below: 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule - 8 Transportation Charges:
Sub Item Code No.
Item Description Distance in km. Transportation Charges in % on the Total Cost of Pipes/ Collars
1 Upto 50 km. 2 Above 50 km. upto 100 km. 3 Above 100 km. upto 150 km. 4 Above 150 km. upto 200 km. 5 Above 200 km.
Inspection & Testing: As per prevailing practice, the following Review of Reports shall be carried out. Review of Reports: The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review: During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively, if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the Inspecting Officer for review.
(K.N.K. Mishra) Incharge PS-VII
![Page 238: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/238.jpg)
No. 238/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JCP/6485 Dated: 10-04-2015 1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes. 2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement. 3. Manufacture’s Test Repot of Rubber Rings shall be submitted for review (incase of Pipes with Socket & Spigot ends). TESTS: As per prevailing practice, the following Tests / Checking shall be carried out. 1. Visual examination, 2. Permeability Test and 3. Three Edge Bearing Test to produce 0.25 mm crack. 4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date amendment shall be carried out if desired by the Consignee. NOTE: 1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. The length in which the pipes are to be supplied shall be as per the mutual agreement between the purchaser and the supplier. However, the recommended length above 300 mm Nominal Diameter is 2.5 meters. 4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. 6. The following information shall be shall be clearly marked on the each Finished Pipe. a. Size of Pipe, b. Class of Pipe, and c. Name of manufacture. 7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of receipt of the materials by the consignee. 8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment towards the supply of Rubber rings will be made) as per the prevailing practice, transportation cost for Pipes & Collars shall be quoted separately.
Recommended by Technical Specification Committee Dated 15-10-2014
(K.N.K. Mishra) Incharge PS-VII
![Page 239: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/239.jpg)
No. 239/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JCP/6485 Dated: 10-04-2015
SCHEDULE ‘B’ (SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi) General Manager
![Page 240: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/240.jpg)
No. 240/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JCP/6485 Dated: 10-04-2015
SCHEDULE – “D”
FORMAT FOR QUATERLY DRAWAL REPORT
Name of the Firm __________________ I- Jan-Mar Report No. __________________ II- Apr-June Rate Contract No. __________________ III- July-Sept. Date of Submission __________________ IV- Oct - Dec Total Position of Order against Rate Contract till the submission of Report. S.No. Name of
Department Quantity and Value of Orders Received (Rs.)
Quantity and Value of Orders Executed (Rs.)
Balance Quantity and Value to be Supplied (Rs.)
Reasons
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all Taxes duties and incidental b) Value of orders supplied during the quarter-Rs. Charges
2. Nil report should also be Submitted.
(Suresh Keshi) General Manager
![Page 241: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/241.jpg)
No. 241/336 S Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking) First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.) EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt) CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004 Website: www.csidc.in, Email : [email protected], [email protected]
No./CSIDC/MKD/ PS-VII /15-16/ Raipur, Dated :
Registered A/D Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCPMC/6486 Dated: 10-04-2015 To,
M/s Bhilai Cement Pipe Manufacturing Co., 70-A, Industrial Estate, Nandini Road, Bhilai (C.G.) Ph.- 0788 - 2286518 Mo.- 9893115028, 9981125028
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 10-04-2015 to 01-04-2016) Ref :- (I) This Office Tender Enquiry No. PS-VII/CSIDC/MKD/102/510/15-16
(II) Bid No. 8387 Dated 19-10-2014 (III) Your Offer acceptance alongwith undertaking submitted on dated 25-03-2015
Dear Sir, You are hereby informed that your above referred tender read with subsequent letters mentioned above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction. You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the time of getting the payment. SCHEDULES ANNEXED: 1. Schedule “A” Description of Stores, Prices, Duties/Taxes . 2. Annexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions of contract (if any). 4. Schedule “C” Information to DDOs about parallel rate contracts. 5. Schedule “D” Format for Drawal Report. Encl. 13 pages
Yours faithfully,
(Suresh Keshi) General Manager
For and on behalf of the purchaser Named in CSIDC Form No.2
![Page 242: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/242.jpg)
No. 242/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCPMC/6486 Dated: 10-04-2015 Copy to, 1. The Secretary, Chhattisgarh Vidhan Sabha ,Raipur .
2. The Registrar, Honourable High court Chhattisgarh, Bilaspur .
3. The Accountant General Chhattisgarh State, Raipur.
4. All HODs of Chhattisgarh Govt. with a request to circulate the copy of R/C to all Direct Demanding Officers of your institution against issue of purchase order (Indent) in Favour of Rate Contract Holders of CSIDC.
5. All Collectors, Chhattisgarh State against issue of purchase order (Indent) in Favour of Rate Contract holders of CSIDC.
6. The Director Treasury, Chhattisgarh Govt., Raipur with a request to circulate copy of R/C to all branches under your control .
7. (i) Director of Public Instruction Department Pension Bada Raipur (ii) Engineer in Chief PHED C.G. Neer Bhawan, Raipur (iii) The Commissioner , Local Administrator , RDA Building Raipur (iv) Engineer in Chief PWD C.G.Civil lines Raipur .
Sr. No. 1 to 7 above are requested to call for original INK-SIGNED Rate Contract for verification to their full satisfaction including validity of various documents like Registration, Tax Registration etc. before taking action i.e. against issue of purchase order in Favour of Rate Contract holders of CSIDC, pre dispatched inspection of stores, acceptance of store.
8. (i) Dy.Director (Q.A.) , DGS&D, Bhilai, Durg (C.G.). (ii) Manager (Operation) Indian Register of Shipping, Senior MIG-2, Secter A, 1st Floor,
Infront of Bank of India Indrapuri Bhopal. (iii) Chief Engineer, PDIL, 4th floor, 4/2 Karaya Road, 67 Shekespeare Sarani, Kolkata (W.B.) (iv) General Manager (Inspection) RITES Ltd., Church gate Station Road, Second Floor, M.K.
Road, Mumbai-400020 (v) Operations Manager SGS India Pvt, Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal (MP)-
462011. above (i) to (v) are requested to call for original INK-SIGNED Rate Contract For Verification to their full satisfaction including validity of various documents like Validity of Registration, BIS Registration etc. before taking action i.e. inspection of stores, as the responsibility rests with the concerned authority. For information and necessary action against Authorized Inspection Agency accorded by CSIDC for inspection of stores.
9. Incharge, Monitoring Cell, MKT-1 CSIDC, Ltd. Raipur for necessary action against inspection of stores . 10. Manager (Tender), Marketing Div., CSIDC Ltd., Raipur. He is requested to maintain a master file
of Rate Contract. 11. Computer cell, CSIDC Ltd., Raipur to release Rate Contract on CSIDC website.
12. Main file of Item- RCC HUME PIPE
(Suresh Keshi) General Manager
![Page 243: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/243.jpg)
No. 243/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCPMC/6486 Dated: 10-04-2015
SCHEDULE “A” Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per Annexure’A’ enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Bhilai Cement Pipe Manufacturing co., THE FIRM 70-A,Industrial Estate,
Nandini Road, Bhilai (C.G.) Ph.- 0788-4050236, 2286518 Mo.- 9893115028, 9981125028
(b) NAME AND FULL ADDRESS OF :- M/s Bhilai Cement Pipe Manufacturing co.,
MANUFACTURER 70-A,Industrial Estate, Nandini Road, Bhilai (C.G.) Ph.- 0788-4050236, 2286518 Mo.- 9893115028, 9981125028
(C) Category :- General 2. VALIDITY OF RATE CONTRACT :- From 10-04-2015 To 01-04-2016 22. DESCRIPTION OF ITEM- RCC HUME PIPE SPECIFICATION, UNIT RATE AS BELOW
S.No. Item Code No. Item Description Class Rate ( )
E.D. VAT/CST Extra As Applicable
Rate Per Meter
Schedule -3: Reinforced Concrete, Medium duty, Non-Pressure Pipes, Class: NP3, with ends of the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
1 RCCHPF80001052 450 1050.00 2 RCCHPF80001054 600 1480.50 3 RCCHPF80001057 900 2936.38
4 RCCHPF80001058 1000 3052.39 5 RCCHPF80001060 1200 4378.50
Schedule - 7 Transportation Charges : Sub Item Code No. Item Description Distance in Km. Transportation Charges in % on the Total Cost of Pipes/Collars.
E.D. VAT/CST Extra 6 RCCHPF80001148 Upto 50 Km. 19.64 7 RCCHPF80001149 Above 50 Km. Upto 100 Km. 21.00 8 RCCHPF80001150 Above 100 Km. Upto 150 Km. 28.88 9 RCCHPF80001151 Above 150 Km. Upto 200 Km. 32.00
10 RCCHPF80001152 Above 200 Km. 37.00 Note :- Technical particulars as per Annexure A enclosed 4. TERMS OF DELIVERY : F. O. R Destination (Any where in C.G.State) 5. EXCISE DUTY : Not Applicable
(Suresh Keshi) General Manager
![Page 244: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/244.jpg)
No. 244/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCPMC/6486 Dated: 10-04-2015 6. SALES TAX /VAT : Extra, as Applicable
TIN No. 22273300016 Address:-
M/s Bhilai Cement Pipe Manufacturing co., 70-A,Industrial Estate, Nandini Road, Bhilai (C.G.) Ph.- 0788-4050236, 2286518 Mo.- 9893115028, 9981125028
7. DELIVERY PERIOD : 45 Days 8. a. ANNUAL TURN OVER/ : NM
b. MONETARY LIMIT : Not Mentioned c. INSTALLED CAPACITY : (as per Durg DTIC Registration Certificate) Description Capacity/Annum
RCC HUME PIPE 35,000 RFT. 9. SLAB DISCOUNT (IF ANY) : Not Mentioned. 10. PRICES : Prices are Firm and Final.
11. MINIMUM QUANTITY IN : Not Mentioned. SINGLE SUPPLY ORDER 12. STATUS OF RC HOLDING : SSI Unit
FIRM 13. REGISTRATION STATUS : Manufacturer is Registered with Durg DTIC DTIC EM Part –II 220101100509 Dated 28-03-2008
14 BIS LICENSE : Not Mentioned 15. PAYING AUTHORITY : As Mentioned in supply order to be issued by Direct Demanding
Officers (DDOs).
16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each consignment there-of will be made after receipt and acceptance of the stores by the consignee/interim consignee in full and good condition within 20 days as per SPR rule No.11, if the bills are in order. In case of delay in payment without any reason the department will be liable to pay interest as per prevailing bank rate. Bills are to be submitted in the prescribed form of the paying authority of purchaser / indenter and are to be supported with inspection note issued by the inspector and consignee’s Receipt Certificate .
17 INSPECTION AUTHORITY : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR
(Suresh Keshi) General Manager
![Page 245: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/245.jpg)
No. 245/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCPMC/6486 Dated: 10-04-2015
Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah) OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
18 QUALITY ASSURANCE : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah) OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
19. PLACE WHERE THE STORES Manufacturer’s Factory at
ARE TO BE OFFERED FOR M/s Bhilai Cement Pipe Manufacturing co., INSPECTION 70-A,Industrial Estate,
Nandini Road, Bhilai (C.G.) Ph.- 0788-4050236, 2286518 Mo.- 9893115028, 9981125028
20 INSPECTION CHARGES : 0.60% Inspection charges + Service Tax As Applicable to be
paid extra at the time of inspection to Quality Assurance Officer which will be billed by the unit along with bill of the material and will be reimbursed by the paying authority of DDO.
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause
7, the Purchaser / DDOs may require the contractor to furnish a security deposit which shall be made after issue of the acceptance of the supply order within the period specified by the purchaser / DDOs. Such security deposit shall not ordinarily exceed 3% . The security shall be in form of Demand Drafts issued by any of the Scheduled Commercial Banks. No other form of security is to be accepted. The security deposit amount is to be refunded after successful completion of the supply.
(Suresh Keshi) General Manager
![Page 246: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/246.jpg)
No. 246/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCPMC/6486 Dated: 10-04-2015
22. Special Note 1. Purchasing Departments / end user will ensure to sending the copy of every order to this office for Approval of inspection Agency against inspection of stores. 2. Purchasing Departments / end user will ensure to Pre
Dispatch inspection of stores Through inspection agency in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to obtained the central excise invoices of Manufacturer as mentioned in the Schedule-A vide sr. no. 1-B if excise duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to execute the Integrity Pact between BUYER and BIDDER/SUPPLIEY in accordance with the letter vide no. 799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi) General Manager
![Page 247: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/247.jpg)
No. 247/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCPMC/6486 Dated: 10-04-2015
Annexure 'A' CSIDC/MKD/TECH/2014-15/14
TECHNICAL PARTICULARS OF R.C.C. HUME PIPES
TSC 15-10-2014
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes (Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish / Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket & Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
The Pipes shall be of the following Sizes & Classification: Schedule- 1: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for collar joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment
Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment. 2. Tenderers may also quote rates separately for the Collars. Dimensions and Design requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003, with up-to-date amendment. Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 248: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/248.jpg)
No. 248/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCPMC/6486 Dated: 10-04-2015 Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment 2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment. Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
20. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 249: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/249.jpg)
No. 249/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCPMC/6486 Dated: 10-04-2015 Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter in mm) , is as per below: 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule - 8 Transportation Charges:
Sub Item Code No.
Item Description Distance in km. Transportation Charges in % on the Total Cost of Pipes/ Collars
1 Upto 50 km. 2 Above 50 km. upto 100 km. 3 Above 100 km. upto 150 km. 4 Above 150 km. upto 200 km. 5 Above 200 km.
Inspection & Testing: As per prevailing practice, the following Review of Reports shall be carried out. Review of Reports: The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review: During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively, if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the Inspecting Officer for review.
(K.N.K. Mishra) Incharge PS-VII
![Page 250: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/250.jpg)
No. 250/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCPMC/6486 Dated: 10-04-2015 1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes. 2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement. 3. Manufacture’s Test Repot of Rubber Rings shall be submitted for review (incase of Pipes with Socket & Spigot ends). TESTS: As per prevailing practice, the following Tests / Checking shall be carried out. 1. Visual examination, 2. Permeability Test and 3. Three Edge Bearing Test to produce 0.25 mm crack. 4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date amendment shall be carried out if desired by the Consignee. NOTE: 1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. The length in which the pipes are to be supplied shall be as per the mutual agreement between the purchaser and the supplier. However, the recommended length above 300 mm Nominal Diameter is 2.5 meters. 4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. 6. The following information shall be shall be clearly marked on the each Finished Pipe. a. Size of Pipe, b. Class of Pipe, and c. Name of manufacture. 7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of receipt of the materials by the consignee. 8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment towards the supply of Rubber rings will be made) as per the prevailing practice, transportation cost for Pipes & Collars shall be quoted separately.
Recommended by Technical Specification Committee Dated 15-10-2014
(K.N.K. Mishra) Incharge PS-VII
![Page 251: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/251.jpg)
No. 251/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCPMC/6486 Dated: 10-04-2015
SCHEDULE ‘B’ (SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi) General Manager
![Page 252: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/252.jpg)
No. 252/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCPMC/6486 Dated: 10-04-2015
SCHEDULE – “D”
FORMAT FOR QUATERLY DRAWAL REPORT
Name of the Firm __________________ I- Jan-Mar Report No. __________________ II- Apr-June Rate Contract No. __________________ III- July-Sept. Date of Submission __________________ IV- Oct - Dec Total Position of Order against Rate Contract till the submission of Report. S.No. Name of
Department Quantity and Value of Orders Received (Rs.)
Quantity and Value of Orders Executed (Rs.)
Balance Quantity and Value to be Supplied (Rs.)
Reasons
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all Taxes duties and incidental b) Value of orders supplied during the quarter-Rs. Charges
2. Nil report should also be Submitted.
(Suresh Keshi) General Manager
![Page 253: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/253.jpg)
No. 253/336 S Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking) First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.) EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt) CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004 Website: www.csidc.in, Email : [email protected], [email protected]
No./CSIDC/MKD/ PS-VII /15-16/ Raipur, Dated :
Registered A/D Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCPI/6487 Dated: 10-04-2015 To,
M/s Bhawani Cement Pipe Industries, D-1, Om Complex, Fafadih Raipur (C.G.) 492001 Ph.- 07714092724 , Mo.- 9425507207
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 10-04-2015 to 01-04-2016) Ref :- (I) This Office Tender Enquiry No. PS-VII/CSIDC/MKD/102/510/15-16
(II) Bid No. 8415 Dated 11-11-2014 (III) Your Offer acceptance alongwith undertaking submitted on dated 26-03-2015
Dear Sir, You are hereby informed that your above referred tender read with subsequent letters mentioned above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction. You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the time of getting the payment. SCHEDULES ANNEXED: 1. Schedule “A” Description of Stores, Prices, Duties/Taxes . 2. Annexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions of contract (if any). 4. Schedule “C” Information to DDOs about parallel rate contracts. 5. Schedule “D” Format for Drawal Report. Encl. 13 pages
Yours faithfully,
(Suresh Keshi) General Manager
For and on behalf of the purchaser Named in CSIDC Form No.2
![Page 254: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/254.jpg)
No. 254/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCPI/6487 Dated: 10-04-2015 Copy to, 1. The Secretary, Chhattisgarh Vidhan Sabha ,Raipur .
2. The Registrar, Honourable High court Chhattisgarh, Bilaspur .
3. The Accountant General Chhattisgarh State, Raipur.
4. All HODs of Chhattisgarh Govt. with a request to circulate the copy of R/C to all Direct Demanding Officers of your institution against issue of purchase order (Indent) in Favour of Rate Contract Holders of CSIDC.
5. All Collectors, Chhattisgarh State against issue of purchase order (Indent) in Favour of Rate Contract holders of CSIDC.
6. The Director Treasury, Chhattisgarh Govt., Raipur with a request to circulate copy of R/C to all branches under your control .
7. (i) Director of Public Instruction Department Pension Bada Raipur (ii) Engineer in Chief PHED C.G. Neer Bhawan, Raipur (iii) The Commissioner , Local Administrator , RDA Building Raipur (iv) Engineer in Chief PWD C.G.Civil lines Raipur .
Sr. No. 1 to 7 above are requested to call for original INK-SIGNED Rate Contract for verification to their full satisfaction including validity of various documents like Registration, Tax Registration etc. before taking action i.e. against issue of purchase order in Favour of Rate Contract holders of CSIDC, pre dispatched inspection of stores, acceptance of store.
8. (i) Dy.Director (Q.A.) , DGS&D, Bhilai, Durg (C.G.). (ii) Manager (Operation) Indian Register of Shipping, Senior MIG-2, Secter A, 1st Floor,
Infront of Bank of India Indrapuri Bhopal. (iii) Chief Engineer, PDIL, 4th floor, 4/2 Karaya Road, 67 Shekespeare Sarani, Kolkata (W.B.) (iv) General Manager (Inspection) RITES Ltd., Church gate Station Road, Second Floor, M.K.
Road, Mumbai-400020 (v) Operations Manager SGS India Pvt, Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal (MP)-
462011. above (i) to (v) are requested to call for original INK-SIGNED Rate Contract For Verification to their full satisfaction including validity of various documents like Validity of Registration, BIS Registration etc. before taking action i.e. inspection of stores, as the responsibility rests with the concerned authority. For information and necessary action against Authorized Inspection Agency accorded by CSIDC for inspection of stores.
9. Incharge, Monitoring Cell, MKT-1 CSIDC, Ltd. Raipur for necessary action against inspection of stores . 10. Manager (Tender), Marketing Div., CSIDC Ltd., Raipur. He is requested to maintain a master file
of Rate Contract. 11. Computer cell, CSIDC Ltd., Raipur to release Rate Contract on CSIDC website.
12. Main file of Item- RCC HUME PIPE
(Suresh Keshi) General Manager
![Page 255: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/255.jpg)
No. 255/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCPI/6487 Dated: 10-04-2015
SCHEDULE “A” Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per Annexure’A’ enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Bhawani Cement Pipe Industries, THE FIRM D-1, Om Complex, Fafadih Raipur (C.G.) 492001
Ph.- 07714092724 , Mo.- 9425507207
(b) NAME AND FULL ADDRESS OF :- M/s Bhawani Cement Pipe Industries, MANUFACTURER Kh.No-521/9 (Part) & 522-4 (Part)
Village Deori Bilaspur Road Raipur (C.G.) 492001 Ph.- 07714092724 , Mo.- 9425507207
(C) Category :- General 2. VALIDITY OF RATE CONTRACT :- From 10-04-2015 To 01-04-2016 23. DESCRIPTION OF ITEM- RCC HUME PIPE SPECIFICATION, UNIT RATE AS BELOW
S.No. Item Code No. Item Description Class Rate ( )
E.D. VAT/CST Extra As Applicable
Rate Per Meter
Schedule -3: Reinforced Concrete, Medium duty, Non-Pressure Pipes, Class: NP3, with ends of the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
1 RCCHPF80001052 450 1050.00 2 RCCHPF80001053 500 1155.00 3 RCCHPF80001054 600 1480.50 4 RCCHPF80001055 700 1680.00 5 RCCHPF80001056 800 2250.00 6 RCCHPF80001057 900 2936.38 7 RCCHPF80001058 1000 3052.39 8 RCCHPF80001060 1200 4378.50 9 RCCHPF80001061 1400 5911.43
10 RCCHPF80001062 1600 7045.31 11 RCCHPF80001063 1800 7793.75
Schedule -5: Reinforced Concrete, Heavy duty, Non-Pressure Pipes, Class: NP4, with ends of the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
12 RCCHPF80001094 450 1037.84 13 RCCHPF80001095 500 1239.91 14 RCCHPF80001096 600 1386.00 15 RCCHPF80001097 700 1732.50 16 RCCHPF80001099 900 2772.00 17 RCCHPF80001100 1000 3291.75 18 RCCHPF80001102 1200 4389.00 19 RCCHPF80001103 1400 5313.00 20 RCCHPF80001104 1600 7507.50
(Suresh Keshi)
General Manager
![Page 256: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/256.jpg)
No. 256/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCPI/6487 Dated: 10-04-2015
Schedule -7: Reinforced Concrete Collar for Reinforced Concrete Light duty, Non-Pressure Pipes, Class: NP2, conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Reinforced Concrete Collar for the Pipes. Class: NP2, Size (Nominal Diameter in mm.) is as per below:
21 RCCHPF80001130 200 51.98 22 RCCHPF80001131 225 61.22 23 RCCHPF80001132 250 63.53
Schedule - 7 Transportation Charges : Sub Item Code No. Item Description Distance in Km. Transportation Charges in % on the Total Cost of Pipes/Collars.
E.D. VAT/CST Extra 24 RCCHPF80001148 Upto 50 Km. 19.64 25 RCCHPF80001149 Above 50 Km. Upto 100 Km. 21.00 26 RCCHPF80001150 Above 100 Km. Upto 150 Km. 28.88 27 RCCHPF80001151 Above 150 Km. Upto 200 Km. 32.00 28 RCCHPF80001152 Above 200 Km. 37.00
Note :- Technical particulars as per Annexure A enclosed 4. TERMS OF DELIVERY : F. O. R Destination (Any where in C.G.State) 5. EXCISE DUTY : Not Applicable
6. SALES TAX /VAT : Extra, as Applicable TIN No. 22411504954 Address:-
M/s Bhawani Cement Pipe Industries, D-1, Om Complex, Fafadih Raipur (C.G.) 492001 Ph.- 07714092724 , Mo.- 9425507207
7. DELIVERY PERIOD : 45 Days 8. a. ANNUAL TURN OVER/ : NM b. MONETARY LIMIT : Not Mentioned c. INSTALLED CAPACITY : (as per Raipur DTIC Registration Certificate) Description Capacity/Annum
RCC HUME PIPE 3000 R.M. 9. SLAB DISCOUNT (IF ANY) : Not Mentioned. 10. PRICES : Prices are Firm and Final. 11. MINIMUM QUANTITY IN : Not Mentioned. SINGLE SUPPLY ORDER 12. STATUS OF RC HOLDING : SSI Unit
FIRM
13. REGISTRATION STATUS : Manufacturer is Registered with Raipur DTIC DTIC EM Part- II 220111100557 Dated 22-05-2008 14 BIS LICENSE : Not Mentioned
(Suresh Keshi) General Manager
![Page 257: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/257.jpg)
No. 257/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCPI/6487 Dated: 10-04-2015
15. PAYING AUTHORITY : As Mentioned in supply order to be issued by Direct Demanding
Officers (DDOs). 16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each
consignment there-of will be made after receipt and acceptance of the stores by the consignee/interim consignee in full and good condition within 20 days as per SPR rule No.11, if the bills are in order. In case of delay in payment without any reason the department will be liable to pay interest as per prevailing bank rate. Bills are to be submitted in the prescribed form of the paying authority of purchaser / indenter and are to be supported with inspection note issued by the inspector and consignee’s Receipt Certificate .
17 INSPECTION AUTHORITY : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah) OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
18 QUALITY ASSURANCE : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah) OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
(Suresh Keshi) General Manager
![Page 258: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/258.jpg)
No. 258/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCPI/6487 Dated: 10-04-2015 19. PLACE WHERE THE STORES Manufacturer’s Factory at
ARE TO BE OFFERED FOR M/s Bhawani Cement Pipe Industries, INSPECTION Kh.No-521/9 (Part) & 522-4 (Part)
Village Deori Bilaspur Road Raipur (C.G.) 492001 Ph.- 07714092724 , Mo.- 9425507207
20 INSPECTION CHARGES : 0.60% Inspection charges + Service Tax As Applicable to be
paid extra at the time of inspection to Quality Assurance Officer which will be billed by the unit along with bill of the material and will be reimbursed by the paying authority of DDO.
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause
7, the Purchaser / DDOs may require the contractor to furnish a security deposit which shall be made after issue of the acceptance of the supply order within the period specified by the purchaser / DDOs. Such security deposit shall not ordinarily exceed 3% . The security shall be in form of Demand Drafts issued by any of the Scheduled Commercial Banks. No other form of security is to be accepted. The security deposit amount is to be refunded after successful completion of the supply.
22. Special Note : 1. Purchasing Departments / end user will ensure to sending the copy of every order to this office for Approval of inspection Agency against inspection of stores.
2. Purchasing Departments / end user will ensure to Pre Dispatch inspection of stores Through inspection agency in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to obtained the central excise invoices of Manufacturer as mentioned in the Schedule-A vide sr. no. 1-B if excise duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to execute the Integrity Pact between BUYER and BIDDER/SUPPLIEY in accordance with the letter vide no. 799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi) General Manager
![Page 259: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/259.jpg)
No. 259/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCPI/6487 Dated: 10-04-2015
Annexure 'A' CSIDC/MKD/TECH/2014-15/14
TECHNICAL PARTICULARS OF R.C.C. HUME PIPES
TSC 15-10-2014
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes (Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish / Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket & Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
The Pipes shall be of the following Sizes & Classification: Schedule- 1: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for collar joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment
Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment. 2. Tenderers may also quote rates separately for the Collars. Dimensions and Design requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003, with up-to-date amendment. Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 260: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/260.jpg)
No. 260/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCPI/6487 Dated: 10-04-2015 Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment 2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment. Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
21. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 261: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/261.jpg)
No. 261/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCPI/6487 Dated: 10-04-2015 Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter in mm) , is as per below: 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule - 8 Transportation Charges:
Sub Item Code No.
Item Description Distance in km. Transportation Charges in % on the Total Cost of Pipes/ Collars
1 Upto 50 km. 2 Above 50 km. upto 100 km. 3 Above 100 km. upto 150 km. 4 Above 150 km. upto 200 km. 5 Above 200 km.
Inspection & Testing: As per prevailing practice, the following Review of Reports shall be carried out. Review of Reports: The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review: During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively, if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the Inspecting Officer for review.
(K.N.K. Mishra) Incharge PS-VII
![Page 262: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/262.jpg)
No. 262/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCPI/6487 Dated: 10-04-2015 1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes. 2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement. 3. Manufacture’s Test Repot of Rubber Rings shall be submitted for review (incase of Pipes with Socket & Spigot ends). TESTS: As per prevailing practice, the following Tests / Checking shall be carried out. 1. Visual examination, 2. Permeability Test and 3. Three Edge Bearing Test to produce 0.25 mm crack. 4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date amendment shall be carried out if desired by the Consignee. NOTE: 1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. The length in which the pipes are to be supplied shall be as per the mutual agreement between the purchaser and the supplier. However, the recommended length above 300 mm Nominal Diameter is 2.5 meters. 4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. 6. The following information shall be shall be clearly marked on the each Finished Pipe. a. Size of Pipe, b. Class of Pipe, and c. Name of manufacture. 7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of receipt of the materials by the consignee. 8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment towards the supply of Rubber rings will be made) as per the prevailing practice, transportation cost for Pipes & Collars shall be quoted separately.
Recommended by Technical Specification Committee Dated 15-10-2014
(K.N.K. Mishra) Incharge PS-VII
![Page 263: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/263.jpg)
No. 263/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCPI/6487 Dated: 10-04-2015
SCHEDULE ‘B’ (SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi) General Manager
![Page 264: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/264.jpg)
No. 264/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCPI/6487 Dated: 10-04-2015
SCHEDULE – “D”
FORMAT FOR QUATERLY DRAWAL REPORT
Name of the Firm __________________ I- Jan-Mar Report No. __________________ II- Apr-June Rate Contract No. __________________ III- July-Sept. Date of Submission __________________ IV- Oct - Dec Total Position of Order against Rate Contract till the submission of Report. S.No. Name of
Department Quantity and Value of Orders Received (Rs.)
Quantity and Value of Orders Executed (Rs.)
Balance Quantity and Value to be Supplied (Rs.)
Reasons
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all Taxes duties and incidental b) Value of orders supplied during the quarter-Rs. Charges
2. Nil report should also be Submitted.
(Suresh Keshi) General Manager
![Page 265: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/265.jpg)
No. 265/336 S Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking) First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.) EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt) CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004 Website: www.csidc.in, Email : [email protected], [email protected]
No./CSIDC/MKD/ PS-VII /15-16/ Raipur, Dated :
Registered A/D Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCP/6488 Dated: 10-04-2015 To,
M/s Bastar Cement Products, Geedam Road, P.O Pandripani, Jagdalpur (Bastar) 494001 Mo.- 9826612012, 9425212012 Email- [email protected]
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 10-04-2015 to 01-04-2016) Ref :- (I) This Office Tender Enquiry No. PS-VII/CSIDC/MKD/102/510/15-16
(II) Bid No. 8420 Dated 14-11-2014 (III) Your Offer acceptance alongwith undertaking submitted on dated 20-03-2015
Dear Sir, You are hereby informed that your above referred tender read with subsequent letters mentioned above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction. You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the time of getting the payment. SCHEDULES ANNEXED: 1. Schedule “A” Description of Stores, Prices, Duties/Taxes . 2. Annexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions of contract (if any). 4. Schedule “C” Information to DDOs about parallel rate contracts. 5. Schedule “D” Format for Drawal Report. Encl. 13 pages
Yours faithfully,
(Suresh Keshi) General Manager
For and on behalf of the purchaser Named in CSIDC Form No.2
![Page 266: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/266.jpg)
No. 266/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCP/6488 Dated: 10-04-2015 Copy to, 1. The Secretary, Chhattisgarh Vidhan Sabha ,Raipur .
2. The Registrar, Honourable High court Chhattisgarh, Bilaspur .
3. The Accountant General Chhattisgarh State, Raipur.
4. All HODs of Chhattisgarh Govt. with a request to circulate the copy of R/C to all Direct Demanding Officers of your institution against issue of purchase order (Indent) in Favour of Rate Contract Holders of CSIDC.
5. All Collectors, Chhattisgarh State against issue of purchase order (Indent) in Favour of Rate Contract holders of CSIDC.
6. The Director Treasury, Chhattisgarh Govt., Raipur with a request to circulate copy of R/C to all branches under your control .
7. (i) Director of Public Instruction Department Pension Bada Raipur (ii) Engineer in Chief PHED C.G. Neer Bhawan, Raipur (iii) The Commissioner , Local Administrator , RDA Building Raipur (iv) Engineer in Chief PWD C.G.Civil lines Raipur .
Sr. No. 1 to 7 above are requested to call for original INK-SIGNED Rate Contract for verification to their full satisfaction including validity of various documents like Registration, Tax Registration etc. before taking action i.e. against issue of purchase order in Favour of Rate Contract holders of CSIDC, pre dispatched inspection of stores, acceptance of store.
8. (i) Dy.Director (Q.A.) , DGS&D, Bhilai, Durg (C.G.). (ii) Manager (Operation) Indian Register of Shipping, Senior MIG-2, Secter A, 1st Floor,
Infront of Bank of India Indrapuri Bhopal. (iii) Chief Engineer, PDIL, 4th floor, 4/2 Karaya Road, 67 Shekespeare Sarani, Kolkata (W.B.) (iv) General Manager (Inspection) RITES Ltd., Church gate Station Road, Second Floor, M.K.
Road, Mumbai-400020 (v) Operations Manager SGS India Pvt, Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal (MP)-
462011. above (i) to (v) are requested to call for original INK-SIGNED Rate Contract For Verification to their full satisfaction including validity of various documents like Validity of Registration, BIS Registration etc. before taking action i.e. inspection of stores, as the responsibility rests with the concerned authority. For information and necessary action against Authorized Inspection Agency accorded by CSIDC for inspection of stores.
9. Incharge, Monitoring Cell, MKT-1 CSIDC, Ltd. Raipur for necessary action against inspection of stores . 10. Manager (Tender), Marketing Div., CSIDC Ltd., Raipur. He is requested to maintain a master file
of Rate Contract. 11. Computer cell, CSIDC Ltd., Raipur to release Rate Contract on CSIDC website.
12. Main file of Item- RCC HUME PIPE
(Suresh Keshi) General Manager
![Page 267: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/267.jpg)
No. 267/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCP/6488 Dated: 10-04-2015
SCHEDULE “A” Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per Annexure’A’ enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Bastar Cement Products, THE FIRM Geedam Road, P.O Pandripani,
Jagdalpur (Bastar) 494001 Mo.- 9826612012, 9425212012 Email- [email protected]
(b) NAME AND FULL ADDRESS OF :- M/s Bastar Cement Products, MANUFACTURER Geedam Road, P.O Pandripani,
Jagdalpur (Bastar) 494001 Mo.- 9826612012, 9425212012 Email- [email protected]
(C) Category :- General 2. VALIDITY OF RATE CONTRACT :- From 10-04-2015 To 01-04-2016 24. DESCRIPTION OF ITEM- RCC HUME PIPE SPECIFICATION, UNIT RATE AS BELOW
S.No. Item Code No. Item Description Class Rate ( )
E.D. VAT/CST Extra As Applicable
Rate Per Meter
Schedule -3: Reinforced Concrete, Medium duty, Non-Pressure Pipes, Class: NP3, with ends of the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
1 RCCHPF80001052 450 1050.00 2 RCCHPF80001053 500 1155.00 3 RCCHPF80001054 600 1480.50 4 RCCHPF80001055 700 1680.00 5 RCCHPF80001056 800 2250.00 6 RCCHPF80001057 900 2936.38 7 RCCHPF80001058 1000 3052.39 8 RCCHPF80001059 1100 3465.00 9 RCCHPF80001060 1200 4378.50
Schedule -5: Reinforced Concrete, Heavy duty, Non-Pressure Pipes, Class: NP4, with ends of the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm. 10 RCCHPF80001094 450 1037.84 11 RCCHPF80001095 500 1239.91 12 RCCHPF80001096 600 1386.00 13 RCCHPF80001097 700 1732.50 14 RCCHPF80001098 800 1963.50 15 RCCHPF80001099 900 2772.00 16 RCCHPF80001100 1000 3291.75 17 RCCHPF80001102 1200 4389.00
(Suresh Keshi)
General Manager
![Page 268: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/268.jpg)
No. 268/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCP/6488 Dated: 10-04-2015
Schedule - 7 Transportation Charges : Sub Item Code No. Item Description Distance in Km. Transportation Charges in % on the Total Cost of Pipes/Collars.
E.D. VAT/CST Extra 18 RCCHPF80001148 Upto 50 Km. 19.64 19 RCCHPF80001149 Above 50 Km. Upto 100 Km. 21.00 20 RCCHPF80001150 Above 100 Km. Upto 150 Km. 28.88 21 RCCHPF80001151 Above 150 Km. Upto 200 Km. 32.00 22 RCCHPF80001152 Above 200 Km. 37.00
Note :- Technical particulars as per Annexure A enclosed 4. TERMS OF DELIVERY : F. O. R Destination (Any where in C.G.State) 5. EXCISE DUTY : Not Applicable 6. SALES TAX /VAT : Extra, as Applicable
TIN No. 22901300646 Address:-
M/s Bastar Cement Products, Geedam Road, P.O Pandripani, Jagdalpur (Bastar) 494001 Mo.- 9826612012, 9425212012 Email- [email protected]
7. DELIVERY PERIOD : 45 Days 8. a. ANNUAL TURN OVER/ : NM
b. MONETARY LIMIT : Not Mentioned c. INSTALLED CAPACITY : (as per Jagdalpur DTIC Registration Certificate) Description Capacity/Annum
RCC HUME PIPE 66175 CFT.
9. SLAB DISCOUNT (IF ANY) : Not Mentioned. 10. PRICES : Prices are Firm and Final. 11. MINIMUM QUANTITY IN : Not Mentioned. SINGLE SUPPLY ORDER 12. STATUS OF RC HOLDING : Manufacturer
FIRM
13. REGISTRATION STATUS : Manufacturer is Registered with Jagdalpur DTIC DTIC EM Part- II 220151100115 Dated 12-03-2009
14 BIS LICENSE : Not Mentioned 15. PAYING AUTHORITY : As Mentioned in supply order to be issued by Direct
Demanding Officers (DDOs).
(Suresh Keshi) General Manager
![Page 269: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/269.jpg)
No. 269/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCP/6488 Dated: 10-04-2015 16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each
consignment there-of will be made after receipt and acceptance of the stores by the consignee/interim consignee in full and good condition within 20 days as per SPR rule No.11, if the bills are in order. In case of delay in payment without any reason the department will be liable to pay interest as per prevailing bank rate. Bills are to be submitted in the prescribed form of the paying authority of purchaser / indenter and are to be supported with inspection note issued by the inspector and consignee’s Receipt Certificate .
17 INSPECTION AUTHORITY : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah) OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
18 QUALITY ASSURANCE : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah) OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
19. PLACE WHERE THE STORES Manufacturer’s Factory at ARE TO BE OFFERED FOR M/s Bastar Cement Products, INSPECTION Geedam Road, P.O Pandripani,
Jagdalpur (Bastar) 494001 Mo.- 9826612012, 9425212012 Email- [email protected]
(Suresh Keshi)
General Manager
![Page 270: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/270.jpg)
No. 270/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCP/6488 Dated: 10-04-2015
20 INSPECTION CHARGES : 0.60% Inspection charges + Service Tax As Applicable to be paid extra at the time of inspection to Quality Assurance Officer which will be billed by the unit along with bill of the material and will be reimbursed by the paying authority of DDO.
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause
7, the Purchaser / DDOs may require the contractor to furnish a security deposit which shall be made after issue of the acceptance of the supply order within the period specified by the purchaser / DDOs. Such security deposit shall not ordinarily exceed 3% . The security shall be in form of Demand Drafts issued by any of the Scheduled Commercial Banks. No other form of security is to be accepted. The security deposit amount is to be refunded after successful completion of the supply.
22. Special Note 1. Purchasing Departments / end user will ensure to sending the copy of every order to this office for Approval of inspection Agency against inspection of stores. 2. Purchasing Departments / end user will ensure to Pre
Dispatch inspection of stores Through inspection agency in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to obtained the central excise invoices of Manufacturer as mentioned in the Schedule-A vide sr. no. 1-B if excise duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to execute the Integrity Pact between BUYER and BIDDER/SUPPLIEY in accordance with the letter vide no. 799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi) General Manager
![Page 271: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/271.jpg)
No. 271/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCP/6488 Dated: 10-04-2015
Annexure 'A' CSIDC/MKD/TECH/2014-15/14
TECHNICAL PARTICULARS OF R.C.C. HUME PIPES
TSC 15-10-2014
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes (Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish / Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket & Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
The Pipes shall be of the following Sizes & Classification: Schedule- 1: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for collar joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment
Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment. 2. Tenderers may also quote rates separately for the Collars. Dimensions and Design requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003, with up-to-date amendment. Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 272: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/272.jpg)
No. 272/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCP/6488 Dated: 10-04-2015 Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment 2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment. Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
22. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 273: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/273.jpg)
No. 273/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCP/6488 Dated: 10-04-2015 Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter in mm) , is as per below: 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule - 8 Transportation Charges:
Sub Item Code No.
Item Description Distance in km. Transportation Charges in % on the Total Cost of Pipes/ Collars
1 Upto 50 km. 2 Above 50 km. upto 100 km. 3 Above 100 km. upto 150 km. 4 Above 150 km. upto 200 km. 5 Above 200 km.
Inspection & Testing: As per prevailing practice, the following Review of Reports shall be carried out. Review of Reports: The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review: During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively, if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the Inspecting Officer for review.
(K.N.K. Mishra) Incharge PS-VII
![Page 274: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/274.jpg)
No. 274/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCP/6488 Dated: 10-04-2015 1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes. 2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement. 3. Manufacture’s Test Repot of Rubber Rings shall be submitted for review (incase of Pipes with Socket & Spigot ends). TESTS: As per prevailing practice, the following Tests / Checking shall be carried out. 1. Visual examination, 2. Permeability Test and 3. Three Edge Bearing Test to produce 0.25 mm crack. 4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date amendment shall be carried out if desired by the Consignee. NOTE: 1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. The length in which the pipes are to be supplied shall be as per the mutual agreement between the purchaser and the supplier. However, the recommended length above 300 mm Nominal Diameter is 2.5 meters. 4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. 6. The following information shall be shall be clearly marked on the each Finished Pipe. a. Size of Pipe, b. Class of Pipe, and c. Name of manufacture. 7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of receipt of the materials by the consignee. 8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment towards the supply of Rubber rings will be made) as per the prevailing practice, transportation cost for Pipes & Collars shall be quoted separately.
Recommended by Technical Specification Committee Dated 15-10-2014
(K.N.K. Mishra) Incharge PS-VII
![Page 275: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/275.jpg)
No. 275/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCP/6488 Dated: 10-04-2015
SCHEDULE ‘B’ (SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi) General Manager
![Page 276: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/276.jpg)
No. 276/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCP/6488 Dated: 10-04-2015
SCHEDULE – “D”
FORMAT FOR QUATERLY DRAWAL REPORT
Name of the Firm __________________ I- Jan-Mar Report No. __________________ II- Apr-June Rate Contract No. __________________ III- July-Sept. Date of Submission __________________ IV- Oct - Dec Total Position of Order against Rate Contract till the submission of Report. S.No. Name of
Department Quantity and Value of Orders Received (Rs.)
Quantity and Value of Orders Executed (Rs.)
Balance Quantity and Value to be Supplied (Rs.)
Reasons
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all Taxes duties and incidental b) Value of orders supplied during the quarter-Rs. Charges
2. Nil report should also be Submitted.
(Suresh Keshi) General Manager
![Page 277: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/277.jpg)
No. 277/336 0S Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking) First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.) EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt) CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004 Website: www.csidc.in, Email : [email protected], [email protected]
No./CSIDC/MKD/ PS-VII /15-16/ Raipur, Dated :
Registered A/D Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/EE/6489 Dated: 10-04-2015 To,
M/s Engineers Enterprises, Rawabhata Industrial Area P.O. Birgaon Raipur (C.G.) 493221 Mo.- 9826612012, 9425212012 Email- [email protected]
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 10-04-2015 to 01-04-2016) Ref :- (I) This Office Tender Enquiry No. PS-VII/CSIDC/MKD/102/510/15-16
(II) Bid No. 8421 Dated 14-11-2014 (III) Your Offer acceptance alongwith undertaking submitted on dated 20-03-2015
Dear Sir, You are hereby informed that your above referred tender read with subsequent letters mentioned above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction. You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the time of getting the payment. SCHEDULES ANNEXED: 1. Schedule “A” Description of Stores, Prices, Duties/Taxes . 2. Annexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions of contract (if any). 4. Schedule “C” Information to DDOs about parallel rate contracts. 5. Schedule “D” Format for Drawal Report. Encl. 13 pages
Yours faithfully,
(Suresh Keshi) General Manager
For and on behalf of the purchaser Named in CSIDC Form No.2
![Page 278: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/278.jpg)
No. 278/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/EE/6489 Dated: 10-04-2015 Copy to, 1. The Secretary, Chhattisgarh Vidhan Sabha ,Raipur .
2. The Registrar, Honourable High court Chhattisgarh, Bilaspur .
3. The Accountant General Chhattisgarh State, Raipur.
4. All HODs of Chhattisgarh Govt. with a request to circulate the copy of R/C to all Direct Demanding Officers of your institution against issue of purchase order (Indent) in Favour of Rate Contract Holders of CSIDC.
5. All Collectors, Chhattisgarh State against issue of purchase order (Indent) in Favour of Rate Contract holders of CSIDC.
6. The Director Treasury, Chhattisgarh Govt., Raipur with a request to circulate copy of R/C to all branches under your control .
7. (i) Director of Public Instruction Department Pension Bada Raipur (ii) Engineer in Chief PHED C.G. Neer Bhawan, Raipur (iii) The Commissioner , Local Administrator , RDA Building Raipur (iv) Engineer in Chief PWD C.G.Civil lines Raipur .
Sr. No. 1 to 7 above are requested to call for original INK-SIGNED Rate Contract for verification to their full satisfaction including validity of various documents like Registration, Tax Registration etc. before taking action i.e. against issue of purchase order in Favour of Rate Contract holders of CSIDC, pre dispatched inspection of stores, acceptance of store.
8. (i) Dy.Director (Q.A.) , DGS&D, Bhilai, Durg (C.G.). (ii) Manager (Operation) Indian Register of Shipping, Senior MIG-2, Secter A, 1st Floor,
Infront of Bank of India Indrapuri Bhopal. (iii) Chief Engineer, PDIL, 4th floor, 4/2 Karaya Road, 67 Shekespeare Sarani, Kolkata (W.B.) (iv) General Manager (Inspection) RITES Ltd., Church gate Station Road, Second Floor, M.K.
Road, Mumbai-400020 (v) Operations Manager SGS India Pvt, Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal (MP)-
462011. above (i) to (v) are requested to call for original INK-SIGNED Rate Contract For Verification to their full satisfaction including validity of various documents like Validity of Registration, BIS Registration etc. before taking action i.e. inspection of stores, as the responsibility rests with the concerned authority. For information and necessary action against Authorized Inspection Agency accorded by CSIDC for inspection of stores.
9. Incharge, Monitoring Cell, MKT-1 CSIDC, Ltd. Raipur for necessary action against inspection of stores . 10. Manager (Tender), Marketing Div., CSIDC Ltd., Raipur. He is requested to maintain a master file
of Rate Contract. 11. Computer cell, CSIDC Ltd., Raipur to release Rate Contract on CSIDC website.
12. Main file of Item- RCC HUME PIPE
(Suresh Keshi) General Manager
![Page 279: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/279.jpg)
No. 279/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/EE/6489 Dated: 10-04-2015
SCHEDULE “A” Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per Annexure’A’ enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Engineers Enterprises, THE FIRM Rawabhata Industrial Area
P.O. Birgaon Raipur (C.G.) 493221 Mo.- 9826612012, 9425212012 Email- [email protected]
(b) NAME AND FULL ADDRESS OF :- M/s Engineers Enterprises, MANUFACTURER Rawabhata Industrial Area
P.O. Birgaon Raipur (C.G.) 493221 Mo.- 9826612012, 9425212012 Email- [email protected]
(C) Category :- General 2. VALIDITY OF RATE CONTRACT :- From 10-04-2015 To 01-04-2016 25. DESCRIPTION OF ITEM- RCC HUME PIPE SPECIFICATION, UNIT RATE AS BELOW
S.No. Item Code No. Item Description Class Rate ( )
E.D. VAT/CST/ Extra As Applicable
Rate Per Meter
Schedule -3: Reinforced Concrete, Medium duty, Non-Pressure Pipes, Class: NP3, with ends of the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
1 RCCHPF80001052 450 1050.00 2 RCCHPF80001053 500 1155.00 3 RCCHPF80001054 600 1480.50
4 RCCHPF80001055 700 1680.00 5 RCCHPF80001056 800 2250.00 6 RCCHPF80001057 900 2936.38 7 RCCHPF80001058 1000 3052.39 8 RCCHPF80001059 1100 3465.00 9 RCCHPF80001060 1200 4378.50
Schedule - 7 Transportation Charges : Sub Item Code No. Item Description Distance in Km. Transportation Charges in % on the Total Cost of Pipes/Collars.
E.D. VAT/CST Extra 10 RCCHPF80001148 Upto 50 Km. 19.64 11 RCCHPF80001149 Above 50 Km. Upto 100 Km. 21.00 12 RCCHPF80001150 Above 100 Km. Upto 150 Km. 28.88 13 RCCHPF80001151 Above 150 Km. Upto 200 Km. 32.00 14 RCCHPF80001152 Above 200 Km. 37.00
Note :- Technical particulars as per Annexure A enclosed
(Suresh Keshi) General Manager
![Page 280: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/280.jpg)
No. 280/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/EE/6489 Dated: 10-04-2015 4. TERMS OF DELIVERY : F. O. R Destination (Any where in C.G.State) 5. EXCISE DUTY : Not Applicable 6. SALES TAX /VAT : Extra, as Applicable
TIN No. 22811300646 Address:-
M/s Engineers Enterprises, Rawabhata Industrial Area P.O. Birgaon Raipur (C.G.) 493221 Mo.- 9826612012, 9425212012 Email- [email protected]
7. DELIVERY PERIOD : 45 Days 8. a. ANNUAL TURN OVER/ : NM b. MONETARY LIMIT : Not Mentioned c. INSTALLED CAPACITY : (as per Raipur DTIC Registration Certificate) Description Capacity/Annum
RCC HUME PIPE & COLLARS 60,000 CFT. 9. SLAB DISCOUNT (IF ANY) : Not Mentioned. 10. PRICES : Prices are Firm and Final. 11. MINIMUM QUANTITY IN : Not Mentioned. SINGLE SUPPLY ORDER 12. STATUS OF RC HOLDING : Manufacturer
FIRM
13. REGISTRATION STATUS : Manufacturer is Registered with Raipur DTIC DTIC EM Part-II 220111100656 Dated 18-09-2008
14 BIS LICENSE : Not Mentioned 15. PAYING AUTHORITY : As Mentioned in supply order to be issued by Direct Demanding
Officers (DDOs).
16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each consignment there-of will be made after receipt and acceptance of the stores by the consignee/interim consignee in full and good condition within 20 days as per SPR rule No.11, if the bills are in order. In case of delay in payment without any reason the department will be liable to pay interest as per prevailing bank rate. Bills are to be submitted in the prescribed form of the paying authority of purchaser / indenter and are to be supported with inspection note issued by the inspector and consignee’s Receipt Certificate .
(Suresh Keshi) General Manager
![Page 281: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/281.jpg)
No. 281/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/EE/6489 Dated: 10-04-2015
17 INSPECTION AUTHORITY : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah) OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
18 QUALITY ASSURANCE : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah) OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
19. PLACE WHERE THE STORES Manufacturer’s Factory at ARE TO BE OFFERED FOR M/s Engineers Enterprises, INSPECTION Rawabhata Industrial Area
P.O. Birgaon Raipur (C.G.) 493221 Mo.- 9826612012, 9425212012 Email- [email protected]
20 INSPECTION CHARGES : 0.60% Inspection charges + Service Tax As Applicable to be paid extra at the time of inspection to Quality Assurance Officer which will be billed by the unit along with bill of the material and will be reimbursed by the paying authority of DDO.
(Suresh Keshi) General Manager
![Page 282: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/282.jpg)
No. 282/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/EE/6489 Dated: 10-04-2015
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause 7, the Purchaser / DDOs may require the contractor to furnish a security deposit which shall be made after issue of the acceptance of the supply order within the period specified by the purchaser / DDOs. Such security deposit shall not ordinarily exceed 3% . The security shall be in form of Demand Drafts issued by any of the Scheduled Commercial Banks. No other form of security is to be accepted. The security deposit amount is to be refunded after successful completion of the supply.
22. Special Note 1. Purchasing Departments / end user will ensure to sending the copy of every order to this office for Approval of inspection Agency against inspection of stores. 2. Purchasing Departments / end user will ensure to Pre
Dispatch inspection of stores Through inspection agency in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to obtained the central excise invoices of Manufacturer as mentioned in the Schedule-A vide sr. no. 1-B if excise duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to execute the Integrity Pact between BUYER and BIDDER/SUPPLIEY in accordance with the letter vide no. 799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi)
General Manager
![Page 283: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/283.jpg)
No. 283/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/EE/6489 Dated: 10-04-2015
Annexure 'A' CSIDC/MKD/TECH/2014-15/14
TECHNICAL PARTICULARS OF R.C.C. HUME PIPES
TSC 15-10-2014
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes (Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish / Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket & Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
The Pipes shall be of the following Sizes & Classification: Schedule- 1: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for collar joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment
Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment. 2. Tenderers may also quote rates separately for the Collars. Dimensions and Design requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003, with up-to-date amendment. Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 284: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/284.jpg)
No. 284/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/EE/6489 Dated: 10-04-2015 Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment 2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment. Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
23. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 285: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/285.jpg)
No. 285/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/EE/6489 Dated: 10-04-2015 Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter in mm) , is as per below: 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule - 8 Transportation Charges:
Sub Item Code No.
Item Description Distance in km. Transportation Charges in % on the Total Cost of Pipes/ Collars
1 Upto 50 km. 2 Above 50 km. upto 100 km. 3 Above 100 km. upto 150 km. 4 Above 150 km. upto 200 km. 5 Above 200 km.
Inspection & Testing: As per prevailing practice, the following Review of Reports shall be carried out. Review of Reports: The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review: During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively, if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the Inspecting Officer for review.
(K.N.K. Mishra) Incharge PS-VII
![Page 286: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/286.jpg)
No. 286/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/EE/6489 Dated: 10-04-2015 1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes. 2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement. 3. Manufacture’s Test Repot of Rubber Rings shall be submitted for review (incase of Pipes with Socket & Spigot ends). TESTS: As per prevailing practice, the following Tests / Checking shall be carried out. 1. Visual examination, 2. Permeability Test and 3. Three Edge Bearing Test to produce 0.25 mm crack. 4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date amendment shall be carried out if desired by the Consignee. NOTE: 1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. The length in which the pipes are to be supplied shall be as per the mutual agreement between the purchaser and the supplier. However, the recommended length above 300 mm Nominal Diameter is 2.5 meters. 4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. 6. The following information shall be shall be clearly marked on the each Finished Pipe. a. Size of Pipe, b. Class of Pipe, and c. Name of manufacture. 7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of receipt of the materials by the consignee. 8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment towards the supply of Rubber rings will be made) as per the prevailing practice, transportation cost for Pipes & Collars shall be quoted separately.
Recommended by Technical Specification Committee Dated 15-10-2014
(K.N.K. Mishra) Incharge PS-VII
![Page 287: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/287.jpg)
No. 287/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/EE/6489 Dated: 10-04-2015
SCHEDULE ‘B’ (SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi) General Manager
![Page 288: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/288.jpg)
No. 288/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/EE/6489 Dated: 10-04-2015
SCHEDULE – “D”
FORMAT FOR QUATERLY DRAWAL REPORT
Name of the Firm __________________ I- Jan-Mar Report No. __________________ II- Apr-June Rate Contract No. __________________ III- July-Sept. Date of Submission __________________ IV- Oct - Dec Total Position of Order against Rate Contract till the submission of Report. S.No. Name of
Department Quantity and Value of Orders Received (Rs.)
Quantity and Value of Orders Executed (Rs.)
Balance Quantity and Value to be Supplied (Rs.)
Reasons
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all Taxes duties and incidental b) Value of orders supplied during the quarter-Rs. Charges
2. Nil report should also be Submitted.
(Suresh Keshi) General Manager
![Page 289: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/289.jpg)
No. 289/336 S Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking) First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.) EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt) CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004 Website: www.csidc.in, Email : [email protected], [email protected]
No./CSIDC/MKD/ PS-VII /15-16/ Raipur, Dated :
Registered A/D Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/GCPI/6490 Dated: 10-04-2015 To,
M/s Grewal Cement Pipe Industries, 31 Industrial Area, P.O. Birgaon 493221 Raipur (C.G.) Mo.- 9826612012 , 9425212012 Email- [email protected]
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 10-04-2015 to 01-04-2016) Ref :- (I) This Office Tender Enquiry No. PS-VII/CSIDC/MKD/102/510/15-16
(II) Bid No. 8422 Dated 14-11-2014 (III) Your Offer acceptance alongwith undertaking submitted on dated 20-03-2015
Dear Sir, You are hereby informed that your above referred tender read with subsequent letters mentioned above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction. You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the time of getting the payment. SCHEDULES ANNEXED: 1. Schedule “A” Description of Stores, Prices, Duties/Taxes . 2. Annexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions of contract (if any). 4. Schedule “C” Information to DDOs about parallel rate contracts. 5. Schedule “D” Format for Drawal Report. Encl. 13 pages
Yours faithfully,
(Suresh Keshi) General Manager
For and on behalf of the purchaser Named in CSIDC Form No.2
![Page 290: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/290.jpg)
No. 290/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/GCPI/6490 Dated: 10-04-2015 Copy to, 1. The Secretary, Chhattisgarh Vidhan Sabha ,Raipur .
2. The Registrar, Honourable High court Chhattisgarh, Bilaspur .
3. The Accountant General Chhattisgarh State, Raipur.
4. All HODs of Chhattisgarh Govt. with a request to circulate the copy of R/C to all Direct Demanding Officers of your institution against issue of purchase order (Indent) in Favour of Rate Contract Holders of CSIDC.
5. All Collectors, Chhattisgarh State against issue of purchase order (Indent) in Favour of Rate Contract holders of CSIDC.
6. The Director Treasury, Chhattisgarh Govt., Raipur with a request to circulate copy of R/C to all branches under your control .
7. (i) Director of Public Instruction Department Pension Bada Raipur (ii) Engineer in Chief PHED C.G. Neer Bhawan, Raipur (iii) The Commissioner , Local Administrator , RDA Building Raipur (iv) Engineer in Chief PWD C.G.Civil lines Raipur .
Sr. No. 1 to 7 above are requested to call for original INK-SIGNED Rate Contract for verification to their full satisfaction including validity of various documents like Registration, Tax Registration etc. before taking action i.e. against issue of purchase order in Favour of Rate Contract holders of CSIDC, pre dispatched inspection of stores, acceptance of store.
8. (i) Dy.Director (Q.A.) , DGS&D, Bhilai, Durg (C.G.). (ii) Manager (Operation) Indian Register of Shipping, Senior MIG-2, Secter A, 1st Floor,
Infront of Bank of India Indrapuri Bhopal. (iii) Chief Engineer, PDIL, 4th floor, 4/2 Karaya Road, 67 Shekespeare Sarani, Kolkata (W.B.) (iv) General Manager (Inspection) RITES Ltd., Church gate Station Road, Second Floor, M.K.
Road, Mumbai-400020 (v) Operations Manager SGS India Pvt, Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal (MP)-
462011. above (i) to (v) are requested to call for original INK-SIGNED Rate Contract For Verification to their full satisfaction including validity of various documents like Validity of Registration, BIS Registration etc. before taking action i.e. inspection of stores, as the responsibility rests with the concerned authority. For information and necessary action against Authorized Inspection Agency accorded by CSIDC for inspection of stores.
9. Incharge, Monitoring Cell, MKT-1 CSIDC, Ltd. Raipur for necessary action against inspection of stores . 10. Manager (Tender), Marketing Div., CSIDC Ltd., Raipur. He is requested to maintain a master file
of Rate Contract. 11. Computer cell, CSIDC Ltd., Raipur to release Rate Contract on CSIDC website.
12. Main file of Item- RCC HUME PIPE
(Suresh Keshi) General Manager
![Page 291: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/291.jpg)
No. 291/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/GCPI/6490 Dated: 10-04-2015
SCHEDULE “A” Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per Annexure’A’ enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Grewal Cement Pipe Industries, THE FIRM 31 Industrial Area, P.O. Birgaon 493221
Raipur (C.G.) Mo.- 9826612012 , 9425212012 Email- [email protected]
(b) NAME AND FULL ADDRESS OF :- M/s Grewal Cement Pipe Industries,
MANUFACTURER 31 Industrial Area, P.O. Birgaon 493221 Raipur (C.G.) Mo.- 9826612012 , 9425212012 Email- [email protected]
(C) Category :- General 2. VALIDITY OF RATE CONTRACT :- From 10-04-2015 To 01-04-2016 26. DESCRIPTION OF ITEM- RCC HUME PIPE SPECIFICATION, UNIT RATE AS BELOW
S.No. Item Code No. Item Description Class Rate ( )
E.D. VAT/CST Extra As Applicable
Rate Per Meter
Schedule -3: Reinforced Concrete, Medium duty, Non-Pressure Pipes, Class: NP3, with ends of the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
1 RCCHPF80001052 450 1050.00 2 RCCHPF80001053 500 1155.00 3 RCCHPF80001054 600 1480.50 4 RCCHPF80001055 700 1680.00 5 RCCHPF80001056 800 2250.00 6 RCCHPF80001057 900 2936.38 7 RCCHPF80001058 1000 3052.39 8 RCCHPF80001059 1100 3465.00 9 RCCHPF80001060 1200 4378.50
Schedule -5: Reinforced Concrete, Heavy duty, Non-Pressure Pipes, Class: NP4, with ends of the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
10 RCCHPF80001094 450 1037.84 11 RCCHPF80001095 500 1239.91 12 RCCHPF80001096 600 1386.00 13 RCCHPF80001097 700 1732.50 14 RCCHPF80001098 800 1963.50 15 RCCHPF80001099 900 2772.00 16 RCCHPF80001100 1000 3291.75 17 RCCHPF80001102 1200 4389.00
(Suresh Keshi)
General Manager
![Page 292: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/292.jpg)
No. 292/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/GCPI/6490 Dated: 10-04-2015
Schedule - 7 Transportation Charges : Sub Item Code No. Item Description Distance in Km. Transportation Charges in % on the Total Cost of Pipes/Collars.
E.D. VAT/CST Extra 18 RCCHPF80001148 Upto 50 Km. 19.64 19 RCCHPF80001149 Above 50 Km. Upto 100 Km. 21.00 20 RCCHPF80001150 Above 100 Km. Upto 150 Km. 28.88 21 RCCHPF80001151 Above 150 Km. Upto 200 Km. 32.00 22 RCCHPF80001152 Above 200 Km. 37.00
Note :- Technical particulars as per Annexure A enclosed 4. TERMS OF DELIVERY : F. O. R Destination (Any where in C.G.State) 5. EXCISE DUTY : Not Applicable 6. SALES TAX /VAT : Extra, as Applicable
TIN No. 22631300648 Address:-
M/s Grewal Cement Pipe Industries, 31 Industrial Area, P.O. Birgaon 493221 Raipur (C.G.) Mo.- 9826612012, 9425212012 Email- [email protected]
7. DELIVERY PERIOD : 45 Days 8. a. ANNUAL TURN OVER/ : NM
b. MONETARY LIMIT : Not Mentioned c. INSTALLED CAPACITY : (as per Raipur DTIC Registration Certificate) Description Capacity/Annum
RCC Hume Pipes, Dust Bins & R.C.C. Half Round Hume Pipe 125000 CFT.
9. SLAB DISCOUNT (IF ANY) : Not Mentioned. 10. PRICES : Prices are Firm and Final. 11. MINIMUM QUANTITY IN : Not Mentioned. SINGLE SUPPLY ORDER 12. STATUS OF RC HOLDING : SSI Unit
FIRM 13. REGISTRATION STATUS : Manufacturer is Registered with Raipur DTIC DTIC EM Part-II 220111100654 Dated 16-09-2008 14 BIS LICENSE : Not Mentioned
15. PAYING AUTHORITY : As Mentioned in supply order to be issued by Direct Demanding Officers (DDOs).
(Suresh Keshi) General Manager
![Page 293: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/293.jpg)
No. 293/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/GCPI/6490 Dated: 10-04-2015
16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each
consignment there-of will be made after receipt and acceptance of the stores by the consignee/interim consignee in full and good condition within 20 days as per SPR rule No.11, if the bills are in order. In case of delay in payment without any reason the department will be liable to pay interest as per prevailing bank rate. Bills are to be submitted in the prescribed form of the paying authority of purchaser / indenter and are to be supported with inspection note issued by the inspector and consignee’s Receipt Certificate .
17 INSPECTION AUTHORITY : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah) OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
18 QUALITY ASSURANCE : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah) OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
19. PLACE WHERE THE STORES Manufacturer’s Factory at
ARE TO BE OFFERED FOR M/s Grewal Cement Pipe Industries, INSPECTION 31 Industrial Area, P.O. Birgaon 493221
Raipur (C.G.) Mo.- 9826612012 , 9425212012 Email- [email protected]
(Suresh Keshi) General Manager
![Page 294: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/294.jpg)
No. 294/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/GCPI/6490 Dated: 10-04-2015
20 INSPECTION CHARGES : 0.60% Inspection charges + Service Tax As Applicable to be paid extra at the time of inspection to Quality Assurance Officer which will be billed by the unit along with bill of the material and will be reimbursed by the paying authority of DDO.
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause
7, the Purchaser / DDOs may require the contractor to furnish a security deposit which shall be made after issue of the acceptance of the supply order within the period specified by the purchaser / DDOs. Such security deposit shall not ordinarily exceed 3% . The security shall be in form of Demand Drafts issued by any of the Scheduled Commercial Banks. No other form of security is to be accepted. The security deposit amount is to be refunded after successful completion of the supply.
22. Special Note 1. Purchasing Departments / end user will ensure to sending the copy of every order to this office for Approval of inspection Agency against inspection of stores. 2. Purchasing Departments / end user will ensure to Pre
Dispatch inspection of stores Through inspection agency in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to obtained the central excise invoices of Manufacturer as mentioned in the Schedule-A vide sr. no. 1-B if excise duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to execute the Integrity Pact between BUYER and BIDDER/SUPPLIEY in accordance with the letter vide no. 799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi) General Manager
![Page 295: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/295.jpg)
No. 295/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/GCPI/6490 Dated: 10-04-2015
Annexure 'A' CSIDC/MKD/TECH/2014-15/14
TECHNICAL PARTICULARS OF R.C.C. HUME PIPES
TSC 15-10-2014
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes (Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish / Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket & Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
The Pipes shall be of the following Sizes & Classification: Schedule- 1: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for collar joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment
Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment. 2. Tenderers may also quote rates separately for the Collars. Dimensions and Design requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003, with up-to-date amendment. Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 296: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/296.jpg)
No. 296/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/GCPI/6490 Dated: 10-04-2015 Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment 2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment. Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
24. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 297: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/297.jpg)
No. 297/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/GCPI/6490 Dated: 10-04-2015 Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter in mm) , is as per below: 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule - 8 Transportation Charges:
Sub Item Code No.
Item Description Distance in km. Transportation Charges in % on the Total Cost of Pipes/ Collars
1 Upto 50 km. 2 Above 50 km. upto 100 km. 3 Above 100 km. upto 150 km. 4 Above 150 km. upto 200 km. 5 Above 200 km.
Inspection & Testing: As per prevailing practice, the following Review of Reports shall be carried out. Review of Reports: The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review: During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively, if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the Inspecting Officer for review.
(K.N.K. Mishra) Incharge PS-VII
![Page 298: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/298.jpg)
No. 298/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/GCPI/6490 Dated: 10-04-2015 1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes. 2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement. 3. Manufacture’s Test Repot of Rubber Rings shall be submitted for review (incase of Pipes with Socket & Spigot ends). TESTS: As per prevailing practice, the following Tests / Checking shall be carried out. 1. Visual examination, 2. Permeability Test and 3. Three Edge Bearing Test to produce 0.25 mm crack. 4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date amendment shall be carried out if desired by the Consignee. NOTE: 1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. The length in which the pipes are to be supplied shall be as per the mutual agreement between the purchaser and the supplier. However, the recommended length above 300 mm Nominal Diameter is 2.5 meters. 4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. 6. The following information shall be shall be clearly marked on the each Finished Pipe. a. Size of Pipe, b. Class of Pipe, and c. Name of manufacture. 7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of receipt of the materials by the consignee. 8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment towards the supply of Rubber rings will be made) as per the prevailing practice, transportation cost for Pipes & Collars shall be quoted separately.
Recommended by Technical Specification Committee Dated 15-10-2014
(K.N.K. Mishra) Incharge PS-VII
![Page 299: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/299.jpg)
No. 299/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/GCPI/6490 Dated: 10-04-2015
SCHEDULE ‘B’ (SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi) General Manager
![Page 300: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/300.jpg)
No. 300/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/GCPI/6490 Dated: 10-04-2015
SCHEDULE – “D”
FORMAT FOR QUATERLY DRAWAL REPORT
Name of the Firm __________________ I- Jan-Mar Report No. __________________ II- Apr-June Rate Contract No. __________________ III- July-Sept. Date of Submission __________________ IV- Oct - Dec Total Position of Order against Rate Contract till the submission of Report. S.No. Name of
Department Quantity and Value of Orders Received (Rs.)
Quantity and Value of Orders Executed (Rs.)
Balance Quantity and Value to be Supplied (Rs.)
Reasons
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all Taxes duties and incidental b) Value of orders supplied during the quarter-Rs. Charges
2. Nil report should also be Submitted.
(Suresh Keshi) General Manager
![Page 301: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/301.jpg)
No. 301/336 Chhattisgarh State Industrial Development Corporation Limited (A Government of Chhattisgarh Undertaking) First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.) EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt) CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004 Website: www.csidc.in, Email : [email protected], [email protected]
No./CSIDC/MKD/ PS-VII /15-16/ Raipur, Dated :
Registered A/D Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/RCCHP&P/6491 Dated: 30-04-2015 To,
M/s R.C.C. Hume Pipe & Products , S.U.I.E. Frazerpur Nayamundapara , Industrial Estate , Jagdalpur Bastar (C.G.) Ph.- 07782227204 Mo.-9425260321, 9406286611 Email- [email protected]
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 30-04-2015 to 01-04-2016) Ref :- (I) This Office Tender Enquiry No. PS-VII/CSIDC/MKD/102/510/15-16
(II) Bid No. 8434 Dated 19-11-2014 (III) Your Offer acceptance alongwith undertaking submitted on dated 27-03-2015
Dear Sir, You are hereby informed that your above referred tender read with subsequent letters mentioned above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction. You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the time of getting the payment. SCHEDULES ANNEXED: 1. Schedule “A” Description of Stores, Prices, Duties/Taxes . 2. Annexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions of contract (if any). 4. Schedule “C” Information to DDOs about parallel rate contracts. 5. Schedule “D” Format for Drawal Report. Encl. 14 pages
Yours faithfully,
(Suresh Keshi) General Manager
For and on behalf of the purchaser Named in CSIDC Form No.2
![Page 302: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/302.jpg)
No. 302/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/RCCHP&P/6491 Dated: 30-04-2015 Copy to, 1. The Secretary, Chhattisgarh Vidhan Sabha ,Raipur .
2. The Registrar, Honourable High court Chhattisgarh, Bilaspur .
3. The Accountant General Chhattisgarh State, Raipur.
4. All HODs of Chhattisgarh Govt. with a request to circulate the copy of R/C to all Direct Demanding Officers of your institution against issue of purchase order (Indent) in Favour of Rate Contract Holders of CSIDC.
5. All Collectors, Chhattisgarh State against issue of purchase order (Indent) in Favour of Rate Contract holders of CSIDC.
6. The Director Treasury, Chhattisgarh Govt., Raipur with a request to circulate copy of R/C to all branches under your control .
7. (i) Director of Public Instruction Department Pension Bada Raipur (ii) Engineer in Chief PHED C.G. Neer Bhawan, Raipur (iii) The Commissioner , Local Administrator , RDA Building Raipur (iv) Engineer in Chief PWD C.G.Civil lines Raipur .
Sr. No. 1 to 7 above are requested to call for original INK-SIGNED Rate Contract for verification to their full satisfaction including validity of various documents like Registration, Tax Registration etc. before taking action i.e. against issue of purchase order in Favour of Rate Contract holders of CSIDC, pre dispatched inspection of stores, acceptance of store.
8. (i) Dy.Director (Q.A.) , DGS&D, Bhilai, Durg (C.G.). (ii) Manager (Operation) Indian Register of Shipping, Senior MIG-2, Secter A, 1st Floor,
Infront of Bank of India Indrapuri Bhopal. (iii) Chief Engineer, PDIL, 4th floor, 4/2 Karaya Road, 67 Shekespeare Sarani, Kolkata (W.B.) (iv) General Manager (Inspection) RITES Ltd., Church gate Station Road, Second Floor, M.K.
Road, Mumbai-400020 (v) Operations Manager SGS India Pvt, Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal (MP)-
462011. above (i) to (v) are requested to call for original INK-SIGNED Rate Contract For Verification to their full satisfaction including validity of various documents like Validity of Registration, BIS Registration etc. before taking action i.e. inspection of stores, as the responsibility rests with the concerned authority. For information and necessary action against Authorized Inspection Agency accorded by CSIDC for inspection of stores.
9. Incharge, Monitoring Cell, MKT-1 CSIDC, Ltd. Raipur for necessary action against inspection of stores . 10. Manager (Tender), Marketing Div., CSIDC Ltd., Raipur. He is requested to maintain a master file
of Rate Contract. 11. Computer cell, CSIDC Ltd., Raipur to release Rate Contract on CSIDC website.
12. Main file of Item- RCC HUME PIPE
(Suresh Keshi) General Manager
![Page 303: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/303.jpg)
No. 303/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/RCCHP&P/6491 Dated: 30-04-2015
SCHEDULE “A” Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per Annexure’A’ enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s R.C.C. Hume Pipe & Products , THE FIRM S.U.I.E. Frazerpur Nayamundapara ,
Industrial Estate , Jagdalpur Bastar (C.G.) Ph.- 07782227204 Mo.-9425260321, 9406286611 Email- [email protected]
(b) NAME AND FULL ADDRESS OF :- M/s R.C.C. Hume Pipe & Products ,
MANUFACTURER S.U.I.E. Frazerpur Nayamundapara , Industrial Estate , Jagdalpur Bastar (C.G.) Ph.- 07782227204 Mo.-9425260321, 9406286611 Email- [email protected]
(C) Category :- General 2. VALIDITY OF RATE CONTRACT :- From 30-04-2015 To 01-04-2016 27. DESCRIPTION OF ITEM- RCC HUME PIPE SPECIFICATION, UNIT RATE AS BELOW
S.No. Item Code No. Item Description Class Rate ( )
E.D. VAT/CST Extra As Applicable
Rate Per Meter
Schedule -3: Reinforced Concrete, Medium duty, Non-Pressure Pipes, Class: NP3, with ends of the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
1 RCCHPF80001052 450 1050.00 2 RCCHPF80001054 600 1480.50 3 RCCHPF80001057 900 2936.38 4 RCCHPF80001058 1000 3052.39 5 RCCHPF80001060 1200 4378.50
Schedule - 7 Transportation Charges : Sub Item Code No. Item Description Distance in Km. Transportation Charges in % on the Total Cost of Pipes/Collars.
E.D. VAT/CST Extra 6 RCCHPF80001148 Upto 50 Km. 19.64 7 RCCHPF80001149 Above 50 Km. Upto 100 Km. 21.00 8 RCCHPF80001150 Above 100 Km. Upto 150 Km. 28.88 9 RCCHPF80001151 Above 150 Km. Upto 200 Km. 32.00
10 RCCHPF80001152 Above 200 Km. 37.00
Note :- Technical particulars as per Annexure A enclosed 4. TERMS OF DELIVERY : F. O. R Destination (Any where in C.G.State) 5. EXCISE DUTY : Not Applicable
(Suresh Keshi) General Manager
![Page 304: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/304.jpg)
No. 304/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/RCCHP&P/6491 Dated: 30-04-2015 6. SALES TAX /VAT : Extra, as Applicable
TIN No. 22162401711
Address:- M/s R.C.C. Hume Pipe & Products , S.U.I.E. Frazerpur Nayamundapara , Industrial Estate , Jagdalpur Bastar (C.G.) Ph.- 07782227204 Mo.-9425260321, 9406286611 Email- [email protected]
7. DELIVERY PERIOD : 30 Days 8. a. ANNUAL TURN OVER/ : 2011-12 Rs. 4452086.00
2012-13 Rs. 6759008.00 2013-14 Rs. 8810258.00
b. MONETARY LIMIT : Not Mentioned c. INSTALLED CAPACITY : (as per Jagdalpur DTIC Registration Certificate) Description Capacity/Annum
R.C.C. Hume Pipes, Urinal, Latrin, Half Round Pipe, Fencing Pole, Km. Stone, Water Tanker, Flower Pot & Dust Bin.
7200 Nos.
9. SLAB DISCOUNT (IF ANY) : Not Mentioned. 10. PRICES : Prices are Firm and Final 11. MINIMUM QUANTITY IN : Not Mentioned. SINGLE SUPPLY ORDER 12. STATUS OF RC HOLDING : Manufacturer
FIRM
13. REGISTRATION STATUS : Manufacturer is Registered with Jagdalpur DTIC DTIC EM Part- II 220151100091 Dated 26-05-2008
14 BIS LICENSE : Not Mentioned 15. PAYING AUTHORITY : As Mentioned in supply order to be issued by Direct Demanding
Officers (DDOs). 16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each
consignment there-of will be made after receipt and acceptance of the stores by the consignee/interim consignee in full and good condition within 20 days as per SPR rule No.11, if the bills are in order. In case of delay in payment without any reason the department will be liable to pay interest as per prevailing bank rate. Bills are to be submitted in the prescribed form of the paying authority of purchaser / indenter and are to be supported with inspection note issued by the inspector and consignee’s Receipt Certificate .
(Suresh Keshi) General Manager
![Page 305: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/305.jpg)
No. 305/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/RCCHP&P/6491 Dated: 30-04-2015
17 INSPECTION AUTHORITY : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah) OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
18 QUALITY ASSURANCE : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah)
OR Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
19. PLACE WHERE THE STORES : Manufacturer’s Factory at
ARE TO BE OFFERED FOR M/s R.C.C. Hume Pipe & Products , INSPECTION S.U.I.E. Frazerpur Nayamundapara ,
Industrial Estate , Jagdalpur Bastar (C.G.) Ph.- 07782227204 Mo.-9425260321, 9406286611 Email- [email protected]
20 INSPECTION CHARGES : 0.60% Inspection charges + Service Tax As Applicable to be
paid extra at the time of inspection to Quality Assurance Officer which will be billed by the unit along with bill of the material and will be reimbursed by the paying authority of DDO.
(Suresh Keshi) General Manager
![Page 306: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/306.jpg)
No. 306/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/RCCHP&P/6491 Dated: 30-04-2015
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause 7, the Purchaser / DDOs may require the contractor to furnish a security deposit which shall be made after issue of the acceptance of the supply order within the period specified by the purchaser / DDOs. Such security deposit shall not ordinarily exceed 3% . The security shall be in form of Demand Drafts issued by any of the Scheduled Commercial Banks. No other form of security is to be accepted. The security deposit amount is to be refunded after successful completion of the supply.
22. Special Note 1. Purchasing Departments / end user will ensure to sending the copy of every order to this office for Approval of inspection Agency against inspection of stores. 2. Purchasing Departments / end user will ensure to Pre
Dispatch inspection of stores Through inspection agency in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to obtained the central excise invoices of Manufacturer as mentioned in the Schedule-A vide sr. no. 1-B if excise duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to execute the Integrity Pact between BUYER and BIDDER/SUPPLIEY in accordance with the letter vide no. 799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi) General Manager
![Page 307: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/307.jpg)
No. 307/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/RCCHP&P/6491 Dated: 30-04-2015
Annexure 'A' CSIDC/MKD/TECH/2014-15/14
TECHNICAL PARTICULARS OF R.C.C. HUME PIPES
TSC 15-10-2014
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes (Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish / Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket & Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
The Pipes shall be of the following Sizes & Classification: Schedule- 1: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for collar joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment
Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment. 2. Tenderers may also quote rates separately for the Collars. Dimensions and Design requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003, with up-to-date amendment. Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 308: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/308.jpg)
No. 308/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/RCCHP&P/6491 Dated: 30-04-2015 Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment 2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment. Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
25. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 309: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/309.jpg)
No. 309/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/RCCHP&P/6491 Dated: 30-04-2015 Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter in mm) , is as per below: 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule - 8 Transportation Charges:
Sub Item Code No.
Item Description Distance in km. Transportation Charges in % on the Total Cost of Pipes/ Collars
1 Upto 50 km. 2 Above 50 km. upto 100 km. 3 Above 100 km. upto 150 km. 4 Above 150 km. upto 200 km. 5 Above 200 km.
Inspection & Testing: As per prevailing practice, the following Review of Reports shall be carried out. Review of Reports: The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review: During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively, if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the Inspecting Officer for review.
(K.N.K. Mishra) Incharge PS-VII
![Page 310: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/310.jpg)
No. 310/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/RCCHP&P/6491 Dated: 30-04-2015 1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes. 2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement. 3. Manufacture’s Test Repot of Rubber Rings shall be submitted for review (incase of Pipes with Socket & Spigot ends). TESTS: As per prevailing practice, the following Tests / Checking shall be carried out. 1. Visual examination, 2. Permeability Test and 3. Three Edge Bearing Test to produce 0.25 mm crack. 4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date amendment shall be carried out if desired by the Consignee. NOTE: 1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. The length in which the pipes are to be supplied shall be as per the mutual agreement between the purchaser and the supplier. However, the recommended length above 300 mm Nominal Diameter is 2.5 meters. 4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. 6. The following information shall be shall be clearly marked on the each Finished Pipe. a. Size of Pipe, b. Class of Pipe, and c. Name of manufacture. 7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of receipt of the materials by the consignee. 8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment towards the supply of Rubber rings will be made) as per the prevailing practice, transportation cost for Pipes & Collars shall be quoted separately.
Recommended by Technical Specification Committee Dated 15-10-2014
(K.N.K. Mishra) Incharge PS-VII
![Page 311: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/311.jpg)
No. 311/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/RCCHP&P/6491 Dated: 30-04-2015
SCHEDULE ‘B’ (SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi) General Manager
![Page 312: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/312.jpg)
No. 312/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/RCCHP&P/6491 Dated: 30-04-2015
SCHEDULE – “D”
FORMAT FOR QUATERLY DRAWAL REPORT
Name of the Firm __________________ I- Jan-Mar Report No. __________________ II- Apr-June Rate Contract No. __________________ III- July-Sept. Date of Submission __________________ IV- Oct - Dec Total Position of Order against Rate Contract till the submission of Report. S.No. Name of
Department Quantity and Value of Orders Received (Rs.)
Quantity and Value of Orders Executed (Rs.)
Balance Quantity and Value to be Supplied (Rs.)
Reasons
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all Taxes duties and incidental b) Value of orders supplied during the quarter-Rs. Charges
2. Nil report should also be Submitted.
(Suresh Keshi) General Manager
![Page 313: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/313.jpg)
No. 313/336 S Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking) First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.) EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt) CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004 Website: www.csidc.in, Email : [email protected], [email protected]
No./CSIDC/MKD/ PS-VII /15-16/ Raipur, Dated :
Registered A/D Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/CPI/6492 Dated: 30-04-2015 To,
M/s Chhattisgarh Pipe Industries, Village - Bhoinabhata Tah. & Distt. Bemetara (C.G.) Mo.- 9993730777
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 30-04-2015 to 01-04-2016) Ref :- (I) This Office Tender Enquiry No. PS-VII/CSIDC/MKD/102/510/15-16
(II) Bid No. 8435 Dated 19-11-2014 (III) Your Offer acceptance alongwith undertaking submitted on dated 15-04-2015
Dear Sir, You are hereby informed that your above referred tender read with subsequent letters mentioned above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction. You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the time of getting the payment. SCHEDULES ANNEXED: 1. Schedule “A” Description of Stores, Prices, Duties/Taxes . 2. Annexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions of contract (if any). 4. Schedule “C” Information to DDOs about parallel rate contracts. 5. Schedule “D” Format for Drawal Report. Encl. 14 pages
Yours faithfully,
(Suresh Keshi) General Manager
For and on behalf of the purchaser Named in CSIDC Form No.2
![Page 314: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/314.jpg)
No. 314/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/CPI/6492 Dated: 30-04-2015 Copy to, 1. The Secretary, Chhattisgarh Vidhan Sabha ,Raipur .
2. The Registrar, Honourable High court Chhattisgarh, Bilaspur .
3. The Accountant General Chhattisgarh State, Raipur.
4. All HODs of Chhattisgarh Govt. with a request to circulate the copy of R/C to all Direct Demanding Officers of your institution against issue of purchase order (Indent) in Favour of Rate Contract Holders of CSIDC.
5. All Collectors, Chhattisgarh State against issue of purchase order (Indent) in Favour of Rate Contract holders of CSIDC.
6. The Director Treasury, Chhattisgarh Govt., Raipur with a request to circulate copy of R/C to all branches under your control .
7. (i) Director of Public Instruction Department Pension Bada Raipur (ii) Engineer in Chief PHED C.G. Neer Bhawan, Raipur (iii) The Commissioner , Local Administrator , RDA Building Raipur (iv) Engineer in Chief PWD C.G.Civil lines Raipur .
Sr. No. 1 to 7 above are requested to call for original INK-SIGNED Rate Contract for verification to their full satisfaction including validity of various documents like Registration, Tax Registration etc. before taking action i.e. against issue of purchase order in Favour of Rate Contract holders of CSIDC, pre dispatched inspection of stores, acceptance of store.
8. (i) Dy.Director (Q.A.) , DGS&D, Bhilai, Durg (C.G.). (ii) Manager (Operation) Indian Register of Shipping, Senior MIG-2, Secter A, 1st Floor,
Infront of Bank of India Indrapuri Bhopal. (iii) Chief Engineer, PDIL, 4th floor, 4/2 Karaya Road, 67 Shekespeare Sarani, Kolkata (W.B.) (iv) General Manager (Inspection) RITES Ltd., Church gate Station Road, Second Floor, M.K.
Road, Mumbai-400020 (v) Operations Manager SGS India Pvt, Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal (MP)-
462011. above (i) to (v) are requested to call for original INK-SIGNED Rate Contract For Verification to their full satisfaction including validity of various documents like Validity of Registration, BIS Registration etc. before taking action i.e. inspection of stores, as the responsibility rests with the concerned authority. For information and necessary action against Authorized Inspection Agency accorded by CSIDC for inspection of stores.
9. Incharge, Monitoring Cell, MKT-1 CSIDC, Ltd. Raipur for necessary action against inspection of stores . 10. Manager (Tender), Marketing Div., CSIDC Ltd., Raipur. He is requested to maintain a master file
of Rate Contract. 11. Computer cell, CSIDC Ltd., Raipur to release Rate Contract on CSIDC website.
12. Main file of Item- RCC HUME PIPE
(Suresh Keshi) General Manager
![Page 315: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/315.jpg)
No. 315/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/CPI/6492 Dated: 30-04-2015
SCHEDULE “A” Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per Annexure’A’ enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Chhattisgarh Pipe Industries, THE FIRM Village - Bhoinabhata
Tah. & Distt. Bemetara (C.G.) Mo.- 9993730777
(b) NAME AND FULL ADDRESS OF :- M/s Chhattisgarh Pipe Industries,
MANUFACTURER Village - Bhoinabhata Tah. & Distt. Bemetara (C.G.) Mo.- 9993730777
(C) Category :- General 2. VALIDITY OF RATE CONTRACT :- From 30-04-2015 To 01-04-2016 28. DESCRIPTION OF ITEM- RCC HUME PIPE SPECIFICATION, UNIT RATE AS BELOW
S.No. Item Code No. Item Description Class Rate ( )
E.D. VAT/CST/ TRANSPORTATION
Extra As Applicable Rate Per Meter
Schedule -3: Reinforced Concrete, Medium duty, Non-Pressure Pipes, Class: NP3, with ends of the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
1 RCCHPF80001052 450 1050.00 2 RCCHPF80001054 600 1480.50 3 RCCHPF80001057 900 2936.38 4 RCCHPF80001058 1000 3052.39 5 RCCHPF80001060 1200 4378.50
Schedule - 7 Transportation Charges : Sub Item Code No. Item Description Distance in Km. Transportation Charges in % on the Total Cost of Pipes/Collars.
E.D. VAT/CST Extra 6 RCCHPF80001148 Upto 50 Km. 19.64 7 RCCHPF80001149 Above 50 Km. Upto 100 Km. 21.00 8 RCCHPF80001150 Above 100 Km. Upto 150 Km. 28.88 9 RCCHPF80001151 Above 150 Km. Upto 200 Km. 32.00
10 RCCHPF80001152 Above 200 Km. 37.00
Note :- Technical particulars as per Annexure A enclosed 4. TERMS OF DELIVERY : F. O. R Destination (Any where in C.G.State) 5. EXCISE DUTY : Not Applicable
(Suresh Keshi) General Manager
![Page 316: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/316.jpg)
No. 316/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/CPI/6492 Dated: 30-04-2015 6. SALES TAX /VAT : Extra, as Applicable
TIN No. 22843702301 Address:-
M/s Chhattisgarh Pipe Industries, Village - Bhoinabhata Tah. & Distt. Bemetara (C.G.) Mo.- 9993730777
7. DELIVERY PERIOD : 45 Days 8. a. ANNUAL TURN OVER/ : NM
b. MONETARY LIMIT : Not Mentioned c. INSTALLED CAPACITY : (as per Durg DTIC Registration Certificate) Description Capacity/Annum
RCC HUME PIPE 1600 Nos. 9. SLAB DISCOUNT (IF ANY) : Not Mentioned. 10. PRICES : Prices are Firm and Final 11. MINIMUM QUANTITY IN : Not Mentioned. SINGLE SUPPLY ORDER 12. STATUS OF RC HOLDING : SSI Unit
FIRM
13. REGISTRATION STATUS : Manufacturer is Registered with Durg DTIC DTIC EM Part- II 220101100637 Dated 01-09-2008
14 BIS LICENSE : Not Mentioned 15. PAYING AUTHORITY : As Mentioned in supply order to be issued by Direct Demanding
Officers (DDOs). 16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each
consignment there-of will be made after receipt and acceptance of the stores by the consignee/interim consignee in full and good condition within 20 days as per SPR rule No.11, if the bills are in order. In case of delay in payment without any reason the department will be liable to pay interest as per prevailing bank rate. Bills are to be submitted in the prescribed form of the paying authority of purchaser / indenter and are to be supported with inspection note issued by the inspector and consignee’s Receipt Certificate .
(Suresh Keshi)
General Manager
![Page 317: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/317.jpg)
No. 317/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/CPI/6492 Dated: 30-04-2015
17 INSPECTION AUTHORITY : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah) OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
18 QUALITY ASSURANCE : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah)
OR Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
19. PLACE WHERE THE STORES : Manufacturer’s Factory at ARE TO BE OFFERED FOR M/s Chhattisgarh Pipe Industries, INSPECTION Village - Bhoinabhata
Tah. & Distt. Bemetara (C.G.) Mo.- 9993730777
20 INSPECTION CHARGES : 0.60% Inspection charges + Service Tax As Applicable to be paid extra at the time of inspection to Quality Assurance Officer which will be billed by the unit along with bill of the material and will be reimbursed by the paying authority of DDO.
(Suresh Keshi) General Manager
![Page 318: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/318.jpg)
No. 318/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/CPI/6492 Dated: 30-04-2015
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause 7, the Purchaser / DDOs may require the contractor to furnish a security deposit which shall be made after issue of the acceptance of the supply order within the period specified by the purchaser / DDOs. Such security deposit shall not ordinarily exceed 3% . The security shall be in form of Demand Drafts issued by any of the Scheduled Commercial Banks. No other form of security is to be accepted. The security deposit amount is to be refunded after successful completion of the supply.
22. Special Note 1. Purchasing Departments / end user will ensure to sending the copy of every order to this office for Approval of inspection Agency against inspection of stores. 2. Purchasing Departments / end user will ensure to Pre
Dispatch inspection of stores Through inspection agency in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to obtained the central excise invoices of Manufacturer as mentioned in the Schedule-A vide sr. no. 1-B if excise duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to execute the Integrity Pact between BUYER and BIDDER/SUPPLIEY in accordance with the letter vide no. 799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi) General Manager
![Page 319: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/319.jpg)
No. 319/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/CPI/6492 Dated: 30-04-2015
Annexure 'A' CSIDC/MKD/TECH/2014-15/14
TECHNICAL PARTICULARS OF R.C.C. HUME PIPES
TSC 15-10-2014
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes (Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish / Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket & Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
The Pipes shall be of the following Sizes & Classification: Schedule- 1: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for collar joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment
Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment. 2. Tenderers may also quote rates separately for the Collars. Dimensions and Design requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003, with up-to-date amendment. Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 320: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/320.jpg)
No. 320/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/CPI/6492 Dated: 30-04-2015 Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment 2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment. Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
26. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 321: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/321.jpg)
No. 321/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/CPI/6492 Dated: 30-04-2015 Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter in mm) , is as per below: 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule - 8 Transportation Charges:
Sub Item Code No.
Item Description Distance in km. Transportation Charges in % on the Total Cost of Pipes/ Collars
1 Upto 50 km. 2 Above 50 km. upto 100 km. 3 Above 100 km. upto 150 km. 4 Above 150 km. upto 200 km. 5 Above 200 km.
Inspection & Testing: As per prevailing practice, the following Review of Reports shall be carried out. Review of Reports: The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review: During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively, if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the Inspecting Officer for review.
(K.N.K. Mishra) Incharge PS-VII
![Page 322: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/322.jpg)
No. 322/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/CPI/6492 Dated: 30-04-2015 1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes. 2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement. 3. Manufacture’s Test Repot of Rubber Rings shall be submitted for review (incase of Pipes with Socket & Spigot ends). TESTS: As per prevailing practice, the following Tests / Checking shall be carried out. 1. Visual examination, 2. Permeability Test and 3. Three Edge Bearing Test to produce 0.25 mm crack. 4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date amendment shall be carried out if desired by the Consignee. NOTE: 1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. The length in which the pipes are to be supplied shall be as per the mutual agreement between the purchaser and the supplier. However, the recommended length above 300 mm Nominal Diameter is 2.5 meters. 4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. 6. The following information shall be shall be clearly marked on the each Finished Pipe. a. Size of Pipe, b. Class of Pipe, and c. Name of manufacture. 7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of receipt of the materials by the consignee. 8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment towards the supply of Rubber rings will be made) as per the prevailing practice, transportation cost for Pipes & Collars shall be quoted separately.
Recommended by Technical Specification Committee Dated 15-10-2014
(K.N.K. Mishra) Incharge PS-VII
![Page 323: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/323.jpg)
No. 323/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/CPI/6492 Dated: 30-04-2015
SCHEDULE ‘B’ (SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi) General Manager
![Page 324: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/324.jpg)
No. 324/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/CPI/6492 Dated: 30-04-2015
SCHEDULE – “D”
FORMAT FOR QUATERLY DRAWAL REPORT
Name of the Firm __________________ I- Jan-Mar Report No. __________________ II- Apr-June Rate Contract No. __________________ III- July-Sept. Date of Submission __________________ IV- Oct - Dec Total Position of Order against Rate Contract till the submission of Report. S.No. Name of
Department Quantity and Value of Orders Received (Rs.)
Quantity and Value of Orders Executed (Rs.)
Balance Quantity and Value to be Supplied (Rs.)
Reasons
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all Taxes duties and incidental b) Value of orders supplied during the quarter-Rs. Charges
2. Nil report should also be Submitted.
(Suresh Keshi) General Manager
![Page 325: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/325.jpg)
No. 325/336 S Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking) First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.) EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt) CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004 Website: www.csidc.in, Email : [email protected], [email protected]
No./CSIDC/MKD/ PS-VII /15-16/ Raipur, Dated :
Registered A/D Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/SI/6493 Dated: 30-04-2015 To,
M/s Star Industries, Mukhtiyarpara Nagpur Manendragarh Korea (C.G.) Mo.- 09424260460, 09993251066
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 30-04-2015 to 01-04-2016) Ref :- (I) This Office Tender Enquiry No. PS-VII/CSIDC/MKD/102/510/15-16
(II) Bid No. 8396 Dated 05-11-2014 (III) Your Offer acceptance alongwith undertaking submitted on dated 26-03-2015
Dear Sir, You are hereby informed that your above referred tender read with subsequent letters mentioned above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction. You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the time of getting the payment. SCHEDULES ANNEXED: 1. Schedule “A” Description of Stores, Prices, Duties/Taxes . 2. Annexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions of contract (if any). 4. Schedule “C” Information to DDOs about parallel rate contracts. 5. Schedule “D” Format for Drawal Report. Encl. 14 pages
Yours faithfully,
(Suresh Keshi) General Manager
For and on behalf of the purchaser Named in CSIDC Form No.2
![Page 326: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/326.jpg)
No. 326/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/SI/6493 Dated: 30-04-2015 Copy to, 1. The Secretary, Chhattisgarh Vidhan Sabha ,Raipur .
2. The Registrar, Honourable High court Chhattisgarh, Bilaspur .
3. The Accountant General Chhattisgarh State, Raipur.
4. All HODs of Chhattisgarh Govt. with a request to circulate the copy of R/C to all Direct Demanding Officers of your institution against issue of purchase order (Indent) in Favour of Rate Contract Holders of CSIDC.
5. All Collectors, Chhattisgarh State against issue of purchase order (Indent) in Favour of Rate Contract holders of CSIDC.
6. The Director Treasury, Chhattisgarh Govt., Raipur with a request to circulate copy of R/C to all branches under your control .
7. (i) Director of Public Instruction Department Pension Bada Raipur (ii) Engineer in Chief PHED C.G. Neer Bhawan, Raipur (iii) The Commissioner , Local Administrator , RDA Building Raipur (iv) Engineer in Chief PWD C.G.Civil lines Raipur .
Sr. No. 1 to 7 above are requested to call for original INK-SIGNED Rate Contract for verification to their full satisfaction including validity of various documents like Registration, Tax Registration etc. before taking action i.e. against issue of purchase order in Favour of Rate Contract holders of CSIDC, pre dispatched inspection of stores, acceptance of store.
8. (i) Dy.Director (Q.A.) , DGS&D, Bhilai, Durg (C.G.). (ii) Manager (Operation) Indian Register of Shipping, Senior MIG-2, Secter A, 1st Floor,
Infront of Bank of India Indrapuri Bhopal. (iii) Chief Engineer, PDIL, 4th floor, 4/2 Karaya Road, 67 Shekespeare Sarani, Kolkata (W.B.) (iv) General Manager (Inspection) RITES Ltd., Church gate Station Road, Second Floor, M.K.
Road, Mumbai-400020 (v) Operations Manager SGS India Pvt, Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal (MP)-
462011. above (i) to (v) are requested to call for original INK-SIGNED Rate Contract For Verification to their full satisfaction including validity of various documents like Validity of Registration, BIS Registration etc. before taking action i.e. inspection of stores, as the responsibility rests with the concerned authority. For information and necessary action against Authorized Inspection Agency accorded by CSIDC for inspection of stores.
9. Incharge, Monitoring Cell, MKT-1 CSIDC, Ltd. Raipur for necessary action against inspection of stores . 10. Manager (Tender), Marketing Div., CSIDC Ltd., Raipur. He is requested to maintain a master file
of Rate Contract. 11. Computer cell, CSIDC Ltd., Raipur to release Rate Contract on CSIDC website.
12. Main file of Item- RCC HUME PIPE
(Suresh Keshi) General Manager
![Page 327: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/327.jpg)
No. 327/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/SI/6493 Dated: 30-04-2015
SCHEDULE “A” Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per Annexure’A’ enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Star Industries, THE FIRM Mukhtiyarpara Nagpur
Manendragarh Korea (C.G.) Mo.- 09424260460, 09993251066
(b) NAME AND FULL ADDRESS OF :- M/s Star Industries,
MANUFACTURER Mukhtiyarpara Nagpur Manendragarh Korea (C.G.) Mo.- 09424260460, 09993251066
(C) Category :- General 2. VALIDITY OF RATE CONTRACT :- From 30-04-2015 To 01-04-2016 29. DESCRIPTION OF ITEM- RCC HUME PIPE SPECIFICATION, UNIT RATE AS BELOW
S.No. Item Code No. Item Description Class Rate ( )
E.D. VAT/CST Extra As Applicable
Rate Per Meter
Schedule -3: Reinforced Concrete, Medium duty, Non-Pressure Pipes, Class: NP3, with ends of the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment Nominal Diameter of Pipes in mm.
1 RCCHPF80001044 100 130.98 2 RCCHPF80001045 150 183.37 3 RCCHPF80001046 200 264.45
4 RCCHPF80001047 225 275.68 5 RCCHPF80001048 250 309.35 6 RCCHPF80001049 300 309.35 7 RCCHPF80001052 450 1050.00 8 RCCHPF80001053 500 1155.00 9 RCCHPF80001054 600 1480.50 10 RCCHPF80001055 700 1680.00 11 RCCHPF80001056 800 2250.00 12 RCCHPF80001057 900 2936.38 13 RCCHPF80001058 1000 3052.39 14 RCCHPF80001059 1100 3465.00 15 RCCHPF80001060 1200 4378.50 16 RCCHPF80001061 1400 5911.43 17 RCCHPF80001062 1600 7045.31 18 RCCHPF80001063 1800 7793.75
Schedule - 7 Transportation Charges : Sub Item Code No. Item Description Distance in Km. Transportation Charges in % on the Total Cost of Pipes/Collars.
(Suresh Keshi)
General Manager
![Page 328: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/328.jpg)
No. 328/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/SI/6493 Dated: 30-04-2015
E.D. VAT/CST Extra 19 RCCHPF80001148 Upto 50 Km. 19.64 20 RCCHPF80001149 Above 50 Km. Upto 100 Km. 21.00 21 RCCHPF80001150 Above 100 Km. Upto 150 Km. 28.88 22 RCCHPF80001151 Above 150 Km. Upto 200 Km. 32.00 23 RCCHPF80001152 Above 200 Km. 37.00
Note :- Technical particulars as per Annexure A enclosed 4. TERMS OF DELIVERY : F. O. R Destination (Any where in C.G.State) 5. EXCISE DUTY : Not Applicable 6. SALES TAX /VAT : Extra, as Applicable
TIN No. 22184802644 Address:-
M/s Star Industries, Mukhtiyarpara Nagpur Manendragarh Korea (C.G.) Mo.- 09424260460, 09993251066
7. DELIVERY PERIOD : 45 Days 8. a. ANNUAL TURN OVER/ : NM
b. MONETARY LIMIT : Not Mentioned c. INSTALLED CAPACITY : (as per Korea DTIC Registration Certificate) Description Capacity/Annum
RCC HUME PIPE 3600 Nos.
9. SLAB DISCOUNT (IF ANY) : Not Mentioned. 10. PRICES : Prices are Firm and Final.
11. MINIMUM QUANTITY IN : Not Mentioned. SINGLE SUPPLY ORDER 12. STATUS OF RC HOLDING : SSI Unit
FIRM
13. REGISTRATION STATUS : Manufacturer is Registered with Korea DTIC DTIC EM Part- II 22/001/12/000143 Dated 23-01-2011
14 BIS LICENSE : Not Mentioned
15. PAYING AUTHORITY : As Mentioned in supply order to be issued by Direct Demanding Officers (DDOs).
(Suresh Keshi) General Manager
![Page 329: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/329.jpg)
No. 329/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/SI/6493 Dated: 30-04-2015 16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each
consignment there-of will be made after receipt and acceptance of the stores by the consignee/interim consignee in full and good condition within 20 days as per SPR rule No.11, if the bills are in order. In case of delay in payment without any reason the department will be liable to pay interest as per prevailing bank rate. Bills are to be submitted in the prescribed form of the paying authority of purchaser / indenter and are to be supported with inspection note issued by the inspector and consignee’s Receipt Certificate .
17 INSPECTION AUTHORITY : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah) OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
18 QUALITY ASSURANCE : Dy. Director (Q &A), DGS&D, Bhilai (C.G.) OR
Manager (Operation) Indian Register of Shipping Senior MIG-2, Secter A, 1st Floor, in front of Bank of India Indrapuri Bhopal. (M.P.)
OR Chief Engineer, Project & Development India Ltd. 4st floor, 4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR General Manager (Inspection) RITES Ltd. Churchgate Station Road, Second Floor, M.K.Road, Mumbai-400020 (Mah) OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR CSIDC (DEPARTMENTAL TECHNICAL WING)
19. PLACE WHERE THE STORES Manufacturer’s Factory at ARE TO BE OFFERED FOR M/s Star Industries, INSPECTION Mukhtiyarpara Nagpur
Manendragarh Korea (C.G.) Mo.- 09424260460, 09993251066
(Suresh Keshi) General Manager
![Page 330: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/330.jpg)
No. 330/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/SI/6493 Dated: 30-04-2015
20 INSPECTION CHARGES : 0.60% Inspection charges + Service Tax As Applicable to be paid extra at the time of inspection to Quality Assurance Officer which will be billed by the unit along with bill of the material and will be reimbursed by the paying authority of DDO.
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause 7, the Purchaser / DDOs may require the contractor to furnish a security deposit which shall be made after issue of the acceptance of the supply order within the period specified by the purchaser / DDOs. Such security deposit shall not ordinarily exceed 3% . The security shall be in form of Demand Drafts issued by any of the Scheduled Commercial Banks. No other form of security is to be accepted. The security deposit amount is to be refunded after successful completion of the supply.
22. Special Note 1. Purchasing Departments / end user will ensure to sending the copy of every order to this office for Approval of inspection Agency against inspection of stores. 2. Purchasing Departments / end user will ensure to Pre
Dispatch inspection of stores Through inspection agency in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to obtained the central excise invoices of Manufacturer as mentioned in the Schedule-A vide sr. no. 1-B if excise duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to execute the Integrity Pact between BUYER and BIDDER/SUPPLIEY in accordance with the letter vide no. 799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi) General Manager
![Page 331: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/331.jpg)
No. 331/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/SI/6493 Dated: 30-04-2015
Annexure 'A' CSIDC/MKD/TECH/2014-15/14
TECHNICAL PARTICULARS OF R.C.C. HUME PIPES
TSC 15-10-2014
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes (Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish / Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket & Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
The Pipes shall be of the following Sizes & Classification: Schedule- 1: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for collar joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment
Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment. 2. Tenderers may also quote rates separately for the Collars. Dimensions and Design requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003, with up-to-date amendment. Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2 shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 332: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/332.jpg)
No. 332/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/SI/6493 Dated: 30-04-2015 Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3 shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment 2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment. Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600 & 1800.
27. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date amendment.
(K.N.K. Mishra) Incharge PS-VII
![Page 333: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/333.jpg)
No. 333/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/SI/6493 Dated: 30-04-2015 Nominal Diameter of Pipes in mm. 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4 shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS: 458/2003(Fourth Revision) with up-to-date amendment. 3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter in mm) , is as per below: 80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,1100,1200, 1400, 1600 & 1800. 1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2 shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment. Schedule - 8 Transportation Charges:
Sub Item Code No.
Item Description Distance in km. Transportation Charges in % on the Total Cost of Pipes/ Collars
1 Upto 50 km. 2 Above 50 km. upto 100 km. 3 Above 100 km. upto 150 km. 4 Above 150 km. upto 200 km. 5 Above 200 km.
Inspection & Testing: As per prevailing practice, the following Review of Reports shall be carried out. Review of Reports: The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review: During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively, if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the Inspecting Officer for review.
(K.N.K. Mishra) Incharge PS-VII
![Page 334: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/334.jpg)
No. 334/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/SI/6493 Dated: 30-04-2015 1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes. 2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement. 3. Manufacture’s Test Repot of Rubber Rings shall be submitted for review (incase of Pipes with Socket & Spigot ends). TESTS: As per prevailing practice, the following Tests / Checking shall be carried out. 1. Visual examination, 2. Permeability Test and 3. Three Edge Bearing Test to produce 0.25 mm crack. 4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date amendment shall be carried out if desired by the Consignee. NOTE: 1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 3. The length in which the pipes are to be supplied shall be as per the mutual agreement between the purchaser and the supplier. However, the recommended length above 300 mm Nominal Diameter is 2.5 meters. 4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision) with up-to-date amendment. 5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-date amendment. 6. The following information shall be shall be clearly marked on the each Finished Pipe. a. Size of Pipe, b. Class of Pipe, and c. Name of manufacture. 7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of receipt of the materials by the consignee. 8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment towards the supply of Rubber rings will be made) as per the prevailing practice, transportation cost for Pipes & Collars shall be quoted separately.
Recommended by Technical Specification Committee Dated 15-10-2014
(K.N.K. Mishra) Incharge PS-VII
![Page 335: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/335.jpg)
No. 335/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/SI/6493 Dated: 30-04-2015
SCHEDULE ‘B’ (SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi) General Manager
![Page 336: Chhattisgarh State Industrial Development Corporation Limited RCC HUME PIPE.pdfAnnexure -“A” Technical Particulars of Item- RCC HUME PIPE 3. Schedule “B” Special conditions](https://reader033.vdocument.in/reader033/viewer/2022060710/60769de8e61dfc5d3037ae44/html5/thumbnails/336.jpg)
No. 336/336 Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/SI/6493 Dated: 30-04-2015
SCHEDULE – “D”
FORMAT FOR QUATERLY DRAWAL REPORT
Name of the Firm __________________ I- Jan-Mar Report No. __________________ II- Apr-June Rate Contract No. __________________ III- July-Sept. Date of Submission __________________ IV- Oct - Dec Total Position of Order against Rate Contract till the submission of Report. S.No. Name of
Department Quantity and Value of Orders Received (Rs.)
Quantity and Value of Orders Executed (Rs.)
Balance Quantity and Value to be Supplied (Rs.)
Reasons
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all Taxes duties and incidental b) Value of orders supplied during the quarter-Rs. Charges
2. Nil report should also be Submitted.
(Suresh Keshi) General Manager