  • Laparoscopic Placement of the BardPort Intraperitoneal Catheter and Reservoir

    Dr. Arlan F. Fuller, Jr.Gillette Center for Women's OncologyMassachusetts General Hospital

  • Choice of Catheter and Reservoir is the IV Device

  • Titanium Port with 9.6F attached catheter

  • Pre-placement ProcedurePerform laparoscopy in the usual manner with umbilical placement of laparoscope trocar and survey of the abdominal cavity for adhesionsPlace a 5 mm operative trocar in a position contralateral to the side of proposed catheter placementIdentify the prospective site in the lower quadrant for entry of the catheter into the peritoneal cavity

  • Mark the site for reservoir placement above the right costal margin

  • Incise the skin and develop a pocket for the reservoir

  • Incise the skin and develop a pocket for the reservoir

  • Check that the reservoir fits snugly into the pocket

  • Place the tunneler on the end of the catheter and start the passage deep to Scarpas fascia

  • Place a 5 mm transverse incision at the target site

  • Bluntly with a hemostat extend the incision beneath Scarpas fascia to contact the tunneler

  • Pass the tunneler out through the target incision

  • Pass the tunneler out through the target incision

  • Pass the catheter through the tunnel and the target incision and cut catheter to remove tunneler

  • Suture the reservoir in place to fascia and confirm catheter function

  • Place introducer needle through target incision adjacent to catheter

  • Visualize needle tip at the target site in the peritoneal cavity

  • Pass the guidewire with J tip through the introducer needle

  • Pass the guidewire with J tip through the introducer needle

  • Visualize J tip of the wire at the target site in the peritoneal cavity

  • Withdraw the introducer needle leaving the guidewire in place

  • Insert the introducer with the 10F dilator over the guidewire into the peritoneal cavity

  • Visualize the dilator AND the peel-away introducer in the peritoneal cavityDilatorDilatorIntroducer

  • Withdraw both the wire and the dilator from the introducer

  • Pass the catheter through the introducer and assist laparoscopically in advancing the catheter into the peritoneal cavity

  • Peel away the introducer while holding the catheter in the peritoneal cavity

  • Advance all the remaining catheter into the peritoneal cavity

  • Adjust position of catheter tip and confirm function by injectionLast, subcuticular closure of all incisions