CIRCUIT BREAKERSCB 8 BREAKER ENCLOSURES & ENCLOSED BREAKERS 100-225 AMPS
1O30OC-ICO30
>^m3Dc/>
LP003CS LC002HS
LC004VS LW200VR
Plug-In Circuit Breaker Enclosures,Insulated Groundable Neutral®
Breaker®Amps Provision Catalog #
ListEach
Std.Pkg.
Approx. KOWgt. Lbs. Fig.
Dim.—Inches8
L W jWire Rangeg
Cu/AI
INDOOR TYPE 1, 2 POLE 120/240V AC125200
MPMD
LC002HSLC004VS
59.00157.00
6.3024.00
•\Th197.
ThWh
47.4
#8-#2/0#4-250 kcmil
INDOOR TYPE 1, 3 POLE 240V AC100 MP LP003CS 106.00 8.00 TO 7)4 41/. #4-#1/0
OUTDOOR® TYPE 3R, 2 POLE 120/240V AC125200
MPMD
LW002HRLW004VR
112.00271.00
10.0029.00
17)419%
Tk8U
n4%
#8-#2/0#4-250 kcmil
OUTDOOR® TYPE 3R, 3 POLE 240V AC100 MP LW903CR 152.00 13.00 17)4 Th 4/4 #4-#1/0
Enclosed Plug-In Circuit Breakers,Insulated Groundable Neutral®Amps
BreakerIncluded Catalog #
ListEach
Std.Pkg.
Approx.Wgt. Lbs.
KOFig.
Dim.—Inches®L W
Wire RangeCu/AI
®
Indoor Type 1, Surface Mounted 2 Pole 120/240V AC100200
MP2100MPD2200
LC100CSLC200VS
192.00452.00
6.9014.10
17)4193/4
7%8%
4'/4
4#8-#2/0#4-250 kcmil
Outdoor® Type 3R, 2 Pole 120/240V AC100200
MP2100 LW100CR 230.00MPD2200 LW200VR 567.00
10.4035.00
17)4193/«
Th8%
4'/4
43/4
#8-#2/0#4-250 kcmil
Bolted Frame Circuit Breaker Enclosures,Insulated Groundable NeutralMax. Breaker ListAmps Provision Catalog # Each
Std.Pkg.
Approx.Wgt. Lbs.
KOFig.
Dim.—Inches®L W j
Wire RangeCu/AI
Indoor Type 1, Surface, 2 and 3 Pole 240V ACWire range shown is maximum allowablefor wire bending space provided. Lug mayaccommodate larger wire. Refer to NationalElectrical Code for specific wire sizes.Accessories—See page CB-12.Knockout Data—See page CB-13.
Wiring Diagrams
225 MQJ LP003QS 144.00 17.00 27 10!4 See Breaker
Outdoor® Type 3R, 2 and 3 Pole 240V AC225 MQJ 2 PoleLW002QR
MQJ 3 Pole LW903QR314.00345.00
19.0021.00
2727
73/41054
5524
See Breaker
LC002HLC100CLW002HLW100C
LC004VLC200VLW004VLW200V
LP003CLW903C LP003QS LW002QR LW903QR
INEUTRALI [£U ,-[&
%=^_A A
[jn r&i r&i
A A A
© Breakers not included. ULtype indicated.® Line Terminals. See appropriate circuit breaker for load
terminal range.®UL Listed for use on systems capable of delivering not
more than 22,000 or 42,000 amps RMS symmetrical,when used with type MQH or MQL breakers respectively.
® UL Listed for use on circuits delivering up to 22,000
amps RMS symmetrical, when appropriate circuitbreaker is installed.
® Provision only for HS type hub. Closure plate included.See accessories for hub selection.
®UL Listed for 10,000 AIC with factory-installed breaker.UL Listed for 22,000 AIC if factory breaker is replacedwith appropriate 22,000 AIC breaker.
© Dimensions shown are representative of outside boxlength, width & depth (± iO and do not includeallowances for mounting bumps, endwalls, covers,hubs or hardware protrusions. Consult factory forspecific details if required.
® Provision only for HS hub. Closure plate included.See accessories for hub selection.
Discount Schedule "A'
CIRCUIT BREAKERSENCLOSURE KNOCKOUT DATA CB
Figi
(
(
Fig
(
jre!
•* —— w — *•
@® fa®@ a
W
D ©®
®D ©
/^« @®cy @®
Lire 4
•« ———— W ———— *•
Ox-xO(HS)o - o
D ®
r\* ®®(2) ®@
D
®
®
®
®
D
®
Figure
L
V
®
®
"1
Figure
i ,
L
®
Figure
Knockout Code — Conduit Sizes
» =A =B =C =D =E =F =G =H =J =K =M =N =P =Q =R =
^ s =% T =K, 3/4 U =%, %, 1 V =14, 1 W =%, %, 1, 1% X =A 1 '/4, 1 K Y =
S/4 Z =
y., i AAX 1, IX BBX 1% CCx 1, r/., ij« EE =
SA 1, V/4, 114, 2 FF =1, 1/4 GG1, r/s, r/s HH1 , IX, 1 'A, 2 J J =
LL =W
1, 1/4, 1 , 2, 2'/£1/4
1/4, 1/
1/4, Vh, 2
1/4, 2
1/., Vh. 2, 2K1'A 21K, 2, 2K= I1/, 2, 2!i 3= 114, 2, 2)4, 3, 3^= 2, 2& 3, 3X
2, 214, 3214, 3
= 214, 3, 314= Tk, 3, 35i 4
314, 43
= 2
(FF)
2
® ®
©
©
X-N®© ®
5
o^^p(HS)
r- — — — — ~H
©
[ ®"a®
7
"o^-^p
(HS)o^ — o
11111
1 ©
© ® ©
(ID
_©_
-«-D-»-
(E)r
©)
Figure 3
©a
a©
Figure
©
© © ©
©
©
© ® ©
6
0. — 0
(HS)o^^o
©® ©
R71
©O
o©)
iiiii
!©
L
L
J/I/IIJ
13I_
_
mtLp,,,
. ...-,.,..,-.,-.-...,........
,..,..,....
r..-.— -, —
——
.
- _
. _
._ .,_ —— , —
——
(C
IRC
UIT
BREAKER
S ^