CSA-BX Series
RoHS compliant
Closed-loop Stepping Driver and Stepping Motor PackageCSA Series
Be sure to read the operation manual for safe operation before using. The product described in this catalogue
is designed and manufactured for the use of general industrial machinery.
Do not use the products for other than the suggested applications.
Safety precaution
Sales office & Sales agent
(81).268.(81).268.
Designed and manufactured by Shinano Kenshi Co., Ltd.
SKJP201705-BX00-XXXXIssued in May 2017 is registered trademark or trademark of Shinano Kenshi Co., Ltd. or its subsidiaries.
〒386-04981078 Kami-maruko, Ueda-shi, Nagano-ken, JAPANURL: http://www.plexmotion.com/english/E-mail: [email protected]
Plexmotion Search
Single shaft
Stalldetection
Closed-loopoperation
Velocity filter
Motor Driver+
Single shaft
Desired function Desired delivery Desired quantity
“Plexmotion”is the authentic standard motor and driver brand
pursuing customer usability
02
CSA SeriesCSA-BX Closed-loop Stepping Driver and Stepping Motor Package ▶P.04〜
Closed-loop Stepping Driver & Stepping Motor Package
Closed-loop operation mode
Open-loop stall detection mode
Smooth acceleration and deceleration with velocity filter
Microstepping driver and stepping motor capable to detect motor stalling (miss step).
Motor keeps operation and traces command pulse without stalling even when excessive acceleration order or impermanent excessive load applies.
Blunt pulse after f ilter makes smooth acceleration/deceleration and reduces vibration.
POINT1 POINT2 POINT3
Stall alarm output
Stall !
Input pulse speed
Motor shaft speed
Tracecommand pu
lse
Speed
Time
0 ms
50 ms
100 ms
100 ms (Filter active)
Vibrationfactors
0 ms (Filter inactive)
Motorvelocity
Time
Torque Range (CSA-BX series)
CSA-BX Series MotorStepping motor with encoder output
□ 42mm □ 56.4mm
CSA-BX42D4E CSA-BX56D3E
▼ P.10 ▼ P.11
Input current (A)1.6
Input current (A)2.8
Step angle (°)0.9 ※
Step angle (°)0.9 ※
※Step angle is at 400ppr resolution setting. It changes to 0.9, 0.45, 0.225 & 0.1125 Deg according to resolution switch setting.
▶P.10〜
Single shaft
Stalldetection
Closed-loopoperation
Velocity filter
Motor Driver+
Single shaft
Outline
Single shaft Single shaft
□42.0
□56.4
CSA-BX42D2E
CSA-BX42D4E
CSA-BX56D1E
CSA-BX56D3E
CSA-BX56D5E
53.0
67.5
56.5
68.5
91.5
□ Size(mm)
Motor length(mm) Item name Pullout Torque (N-m)
0 0.1 0.2 0.4 0.6 0.8 1.0 1.5 2.0 3.0
3.0
03
Clo
se
d-lo
op
Ste
pp
ing
Driv
er a
nd
Ste
pp
ing
Mo
tor P
ac
ka
ge
CS
A-B
XS
erie
sC
SA
-BX
42
DS
erie
s Mo
tor
Driv
er
Lin
eu
pC
SA
-BX
56
DS
erie
s Mo
tor
Fe
atu
res
CSA-BX SeriesCSA-BX Closed-loop Stepping Driver and Stepping Motor Package
Features
Product lineup
● 2 unique operation modes for different application and situationOpen-loop stall detection modeClosed-loop operation mode
● Smooth acceleration and deceleration with velocity filter● Selectable in 4 steps resolution setting : 400, 800, 1,600 & 3,200 PPR● DC24V input and 13 steps current setting : 0.6 - 3.0A● Protective function : Overheat, Excessive regenerative voltage, Low voltage, Excessive
load, Excessive velocity● Automatic power down function
Model Shaft □ Size[mm] Item name Motor length
[mm]Motor mass
[kg]Rotor inertia
[g-cm 2 ]
MotorInfor-
mation
Motor cable P/N
(P.09)
Closed-loop Stepping Driver and
Stepping Motor Package
Singleshaft
42.0
CSA-BX42D2E 53.0 0.29 40
P.10 PCSA28
CSA-BX42D4E 67.5 0.42 70
56.4
CSA-BX56D1E 56.5 0.51 153
P.11 PCSA29CSA-BX56D3E 68.5 0.71 290
CSA-BX56D5E 91.5 1.10 513
Single shaft
Stalldetection
Closed-loopoperation
Velocity filter
Motor Driver+
Single shaft
04
53.63327.16.4
3 3
84 8490
45.5
3.53.5
Standard package1. Driver 2. Motor 3. Motor-Driver cable (60cm)4. Driver signal cable (60cm) 5. Driver power cable (60cm) 6. Operation manual
Driver SpecificationsPower supply voltage DC24V±10%Current consumption 2A MaxDriving method 2 phase bipolar chopper driveOutput current 3.0A Max. (Peak current)Maximum input frequency 80kHz
Resolution 400P/R (0.9Deg.), 800P/R(0.45Deg.), 1,600P/R(0.225Deg.), 3,200P/R(0.1125Deg.)Bracket() shows step angle at each resolution setting.
Input signal
1) Pulse signal2) Motor enable (Current On/Off)3) Stall alarm clear4) Automatic power down enable : 100ms after pulse signal input stopped※ Input voltage DC5 to 30V, Photocoupler input (Input resistor 330 ohms). Photocoupler current 10mA or
less.
Output signal
1) Ready/Busy signal2) Stall alarm signal3) System error alarm※Output voltage DC5 to 30V, Photocoupler open collector . Sink current 10mA or less.
Function setting
1) Motor operation mode setting (Open-loop stall detection mode / Closed-loop mode)2) Velocity filter setting (0 / 2 / 5 / 10 / 20 / 50 / 70 / 100 ms)3) Resolution setting (400 / 800 / 1,600 / 3,200 P/R)4) Pulse input mode setting (1 pulse mode / 2 pulse mode)5) Running current setting (0.6 / 0.8 / 1.0/ 1.2 / 1.4 / 1.6 / 1.8 / 2.0 / 2.2 / 2.4 / 2.6 / 2.8 / 3.0 A)6) Automatic power down current setting (Running current setting X 50% / Running current setting X 25%)
Indicator
1) Power LED : Turn on when power is on2) Alarm LED : Turn on when position deviation between rotor position and input pulse occurs in closed-loop
operation modeBlinking when stall or system alarm occurs.※Possible to identify error type from blinking cycle.
Protective function
1) Driver protective function System alarm output and motor stops without energized under the following conditions. ・Overheat protection: The temperature of the thermistor on the driver board reaches 80 Deg.C ・Low voltage protection: The input voltage goes less than 18VDC ・Excessive regenerative voltage protection: The regenerative voltage goes more than 32VDC ・Excessive load protection : More than 3.6 Deg position deviation between rotor position and input pulse
continues in 5 seconds. ・Excessive velocity protection : Input pulse exceeds 80Khz or motor rotation velocity reaches 3,500 r/min2) Blown fuse : 250V 5A Time delay type
Others 1) RoHS compliant2) Locking connector
Operating ambient temperature 0 to 40 Deg.C. No freezing.
Operating ambient humidity 85% or less. No condensingStorage temperature -10 to + 50 Deg.C. No freezingStorage humidity 85% or less. No condensingAtmosphere No corrosive gas, no dust surroundings, No water and oil splash.Dimensions W90 X D60 XH33 mmMass 0.08kg
Driver Dimensions
※CAD Data (2D & 3D) download page http:/www.skcj.co.jp/plexmotion/english/download/
05
CS
A-B
XS
erie
sC
SA
-BX
42
DS
erie
s Mo
tor
Driv
er
Lin
eu
pC
SA
-BX
56
DS
erie
s Mo
tor
Fe
atu
res
Clo
se
d-lo
op
Ste
pp
ing
Driv
er a
nd
Ste
pp
ing
Mo
tor P
ac
ka
ge
Connection / Setting
CN1
CN3
CN2
Input/Output signal specifications
CN2 Signal connector
CN3 Motor connector
CN1 Power suply connector
Pin Signal Specifications/Description
1(RD) Vcc DC24V ±10%
2(BK) GND Power GND
Pin Signal Specifications/Description
1(WT) ENC_B Encoder B phase
2(GN) ENC_A Encoder A phase
3(BK) GND Encoder GND
4(BL) +5V Encoder power
5(YL)_B_
Motor _B_
phase
6(OR) A Motor A phase
7(RD) B Motor B phase
8(BR) A Motor A phase
Pin Signal Signal type Function Specifications/Description
1(BR) NC −
N/A ・N/A Do not connect anything
2(BR/WT) NC −
3(RD/WT) NC −
4(RD) NC −
5(OR/WT) MST −Out Stall alarm signal
OFF: Open-loop stall detection mode - Motor stall: Closed-loop operation mode - Excessive deviation error
or excessive load errorON : Normal operation6(OR) MST +
7(YL/WT) ALARM −Out System alarm sig-
nalOFF: System alarmON :Normal operation
8(YL) ALARM +
9(GN/WT) READY/BUSY −Out Ready/Busy signal OFF:Motor operation execute
ON :Motor stop10(GN) READY/BUSY +
11(BL/WT) AUTO_CURRENT −In Automatic power
down enable signal
OFF:Motor holding current goes to SW1 No.5pin set current 100ms after pulse signal input stopped.
ON :Motor holding current is maintained at running current at SW212(BL) AUTO_CURRENT +
13(VT/WT) MST_CLR −In Stall alarm clear
signalOFF:Normal operationON :Stall alarm clear
14(VT) MST_CLR +
15(GR/WT) ENABLE −In Motor current en-
able signalOFF:Current disableON :Current enable
16(GR) ENABLE +
17(BK/WT) CCW − (DIR − )In CCW pulse signal
(Direction signal)
・2 pulse input mode - CCW pulse signal input・1 pulse input mode - Direction signal input
OFF:CW direction / ON:CCW direction18(WT) CCW + (DIR + )
19(PK/WT) CW − (PLS − )In CW pulse signal
(Pulse signal)・2 pulse input mode - CW pulse signal input・1 pulse input mode - Pulse signal input
20(PK) CW + (PLS + )
※Bracket ( ) after pin number shows cable color.※"OFF" in chart shows photocoupler off condition and "ON" in chart shows photocoupler on condition respectively.※CW shows clockwise direction and CCW shows counterclockwise direction viewed from motor mounting surface.
※Bracket ( ) after pin number shows cable color.
※Bracket ( ) after pin number shows cable color.
06
Input and Output Circuit
Pin 9, 7, 5
Pin 10, 8, 6330Ω
Pin 20, 18, 16 14, 12
Pin 19, 17, 15 13, 11
5~10mA
10mA(Max)
Input circuit Output circuit
Connection with Other Peripherals
1(RD)2(BK)
20(PK)
19(PK/WT)
18(WT)
17(BK/WT)
16(GR)
15(GR/WT)
14(VT)
13(VT/WT)
12(BL)
11(BL/WT)
10(GN)
9(GN/WT)
8(YL)
7(YL/WT)
6(OR)
5(OR/WT)
4(RD)
3(RD/WT)
2(BR/WT)
1(BR)
CN1
CN2
CN3
Power supply (DC24V) Driver
Controller
Stepping motor
Vcc (DC24V)
GND
R1
R1
R1
R1
R1
R2
R2
R2
CW+(PLS+)
CW-(PLS-)CCW+(DIR +)
CCW-(DIR -)ENABLE+
ENABLE-MST_CLR+
MST_CLR-AUTO_CURRENT+
AUTO_CURRENT-
READY/BUSY+
READY/BUSY-ALARM+
ALARM-MST+
MST-NC
NCNC
NC
GND
GND
+V(DC5~30V)
+V(DC5~30V)
Power supply
CW pulse signal(Pulse signal)
CCW pulse signal(Direction signal)
Motor enable signal
Stall alarm clear signal
Automatic power down enable signal
Ready/Busy signal
System alarm signal
Stall alarm signal
No connection
No connection
12345678
(WT)(GN)(BK)(BL)(YL)(OR)(RD)(BR)
ENC_BENC_AGND+5VBABA
Input signal
Output signal
※Bracket ( ) after pin number shows cable color.※R1 and R2 shows external resistors for current limit.
Connection for input/output signals
● Input signal1) Connect to controller directly
without resistor R1, when apply-ing DC5V to +V.
2) Use external resistor R1 to keep photocoupler current not to ex-ceed 10mA, when applying more than DC5V to +V
Example : R1=Approximately 2K ohms, when +V = 24VDC.
● Output signal1) Keep photocoupler current 10mA
or lower confirming with the specifications of the controller.
2) Use external resistor R2 to keep photocoupler current not to exceed 10mA, when expected current exceeds 10mA.
07
CS
A-B
XS
erie
sC
SA
-BX
42
DS
erie
s Mo
tor
Driv
er
Lin
eu
pC
SA
-BX
56
DS
erie
s Mo
tor
Fe
atu
res
Clo
se
d-lo
op
Ste
pp
ing
Driv
er a
nd
Ste
pp
ing
Mo
tor P
ac
ka
ge
DIP and rotary switches
LED indicator
SW1 Pin No. Resolution(Pulse/Rotation)
Step Angle(Deg/Pulse)1 2
ON ON 400P/R 0.9°ON OFF 800P/R 0.45°OFF ON 1600P/R 0.225°OFF OFF 3200P/R 0.1125°
LED Name Color Type Status
Power LED Green Light Power on
Alarm LED Orange
Light
Position deviation occurs in closed-loop mode
Blink Stall alarm / System error
Blinking cycle Error type Cause
2 Stall detection Motor stalling in open-loop stall detection mode
3Excessive deviation Excessive position deviation in closed-loop op-
eration modeExcessive load Excessive load in closed-loop operation mode
4 Overheat Temperature of the thermistor on driver board reaches 80Deg.C
5 Excessive regenera-tive voltage
Internal voltage goes more than 32VDC by re-generative voltage.
6 Low voltage Input voltage goes less than 18VDC
7 Excessive velocity Input pulse exceeds 80Khz or motor rotation ve-locity reaches 3,500 r/min
8 System error Problem of driver IC 9 Initialization error Motor initialization error
Resolution setting (SW1: Pin No. 1 & 2)
LED display function Alarm LED Blinking cycle and Error description
SW1 SW2
SW1 Pin No.Pulse input mode
3ON 2 pulse input mode (CW/CCW)OFF 1 pulse input mode (PLS/DIR)
Pulse input mode setting (SW1: Pin No. 3)
Motor operation mode setting (SW1:Pin No. 4)
Automatic power down setting (SW1:Pin No. 5) Running current setting (SW2)
Rotary SW setting Current [A] ( ± 20%)
0 0.61 0.82 1.03 1.24 1.45 1.66 1.87 2.08 2.29 2.4A 2.6B 2.8C 3.0D 3.0E 3.0F 3.0
SW1 Pin No. Motor operation mode Function Description
4
ON Open-loop stall de-tection mode
Output alarm signal (MST) and stop motor operation without energized when mo-tor stalls.
Motor runs in open-loop operation.Motor stall : When more than 3.6 Deg. deviation between rotor position and input pulse occurs, output stall alarm (MST) and motor stops without energized.
OFF Closed-loop mode
Motor keeps operation and t races command pu lse without stalling even when excessive acceleration or-der or impermanent exces-sive load applies.
Motor runs in closed-loop operation. Motor keeps opera-tion and trace command pulse even when the deviation between rotor position and input pulse occurs by excessive acceleration or impermanent excessive load.Excessive deviation error : When the position deviation exceeds 1080 Deg, output stall alarm (MST) and motor stops without energized.Excessive load error : When more than 3.6 Deg deviation condition continues more than 5 seconds, output stall alarm and motor stops without energized.
SW1 Pin No.Setting
5ON Running current setting X 50%OFF Running current setting X 25%
Velocity filter setting (SW1: Pin No.6~8)SW1 Pin No.
Setting Velocity filter setting image6 7 8
ON ON ON 0ms (Filter inactive)
ON ON OFF 2msON OFF ON 5msON OFF OFF 10msOFF ON ON 20msOFF ON OFF 50msOFF OFF ON 70msOFF OFF OFF 100ms
Time
Mo t o r v e l o c i t y
0 ms
50 ms
100 ms
08
Timing chartMotor operation and timing chart
Stall alarm clear timing chart
Motor operation
Power input
2 pulse input mode
System alarm signal
Ready/Busy signal
Stall alarm signal
CW pulse signal
CCW pulse signal
Pulse signal
Direction signal
Motor enable signal
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
CW
CCW
0.5sor more
0.1s or more
0.1s or more
Initializing operation ※3
Initializing operation ※3
0.1s or more0.1s or more0.1s or more0.1s or more0.1s or more0.1s or more
0.05s or more0.05s or more
0.1s or more
5s or more
※4
※6
※2
※1※2
※6
※4
0.05s or more
※4
0.05s or more0.05s or more
0.05s or more
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
Motor operationCW
CCW
2 pulseinput mode
Ready/Busy signal
Stall alarm signal
CW pulse signal
CCW pulse signal
Pulse signal
Direction signal
Stall alarm clear signal
Motor stall/Excessive position deviation or Excessive load
10ms or more
Pulse input timing chart
ON
OFF
90%
10%
ON
OFF
CW pulse signal
CCW pulse signal
20μs or more6.25μs or more
2μs or less
2μs or less
※1
※2
※5
※5
※5
1 pulse input mode
Initializing operation ※3
1 pulseinput mode
Cable specifications
Motor-Driver cable PCSA28 Motor-Driver cable PCSA29
Driver signal cable Driver power cable
AWG 24UL 3265JST ZER-08V-S
Motor sideJST PAP-08V-SDriver side
12345678
WTGNBKBLYLORRDBR
87654321
BRRDORYLBLBKGNWT
60cm
AWG 22UL 3265JST PAP-08V-S
Motor sideJST PAP-08V-SDriver side
12345678
87654321
60cm
BRRDORYLBLBKGNWT
WTGNBKBLYLORRDBR
60cm
AWG 22UL 1007JST XAP-02V-1
21
BKRD2
468101214161820
60cm
AWG 26UL 1061JST GHDR-20V-S(F)
BR/WTRDORYLGNBLVTGRWTPK
135791113151719
BRRD/WTOR/WTYL/WTGN/WTBL/WTVT/WTGR/WTBK/WTPK/WT
※1 CW shows clockwise direction and CCW shows counterclockwise direction viewed from motor mounting surface.※2 "OFF" in chart shows photocoupler off condition and "ON" in chart shows photocoupler on condition respectively.※3 Initializing operating time varies in load condition.※4 Acceleration/Deceleration time varies in operation mode, velocity filter setting and load condition.※5 Ready/Busy signal time lag varies in operation mode, velocity filter setting and load condition.※6 Command pulse signal (CW/CCW) is ignored when stall alarm signal outputs.
09
CS
A-B
XS
erie
sC
SA
-BX
42
DS
erie
s Mo
tor
Driv
er
Lin
eu
pC
SA
-BX
56
DS
erie
s Mo
tor
Fe
atu
res
Clo
se
d-lo
op
Ste
pp
ing
Driv
er a
nd
Ste
pp
ing
Mo
tor P
ac
ka
ge
Motor specifications
Operating ambient temperature 0 to + 40 Deg.C. No freezingOperating ambient humidity 85% or less. No condensingStorage temperature -20 to 70 Deg.C. No freezingStorage humidity 85% or less. No condensing
Atmosphere No corrosive gas, no dust surroundings, no water and oil splash.
Improper motor operation may cause excessive temperature rising. Operate the motor keeping the motor surface temperature 70Deg. C or lower.
20±0.5
15
L
4.5
φ22
-0-0.03
φ5-0-0.012
24-M3×0.5Depth 4.5min.
31
□42
31
12345678
Pin No.
CSA-BX42D SeriesStepping motorDimensions
Refer to chart below for motor length
・ Permissible thrust load to the shaft : 3.5N (0.35kgf)
・ Permissible radial load to the shaft : 20N (2kgf)
※Keep the load within permissible load value. Otherwise, it may cause the shaft to bend or break. Radial load value is measured at the top of the output shaft.
Speed and torque SpecificationsCSA-BX42D4E(1.6A)
0 2000 4000 6000 8000 10000
Frequency【pps】(400P/R)
Torque【N-m】
Input current【A】
0.40
0.30
0.20
0.10
0.00
4.0
3.0
2.0
1.0
0.0
TorqueInput current
0 300 600 900 1200 1500
Speed【r/min】
※Torque on graph shows pull out torque. ▲shows maximum starting frequency. ※Measurement conditions : DC24V input and 400P/R resolution, Open-loop stall detection mode. Load inertia 47g-cm2
※1 Maximum resolution is 3,200P/R with resolution setting switch on driver
8
6
7 5
A
A
BB
Wiring diagram Pin No. 1 2 3 4 5 6 7 8
Signal ENC_B ENC_A GND +5V_B
_A B A
2 phase Single shaft
Bipolar/Encoderoutput
※CAD Data (2D & 3D) download page http:/www.skcj.co.jp/plexmotion/english/download/
Model Shaft Item nameResolution
[P/R]※ 1
Input current
[A/phase]
Holding torque[N-m]
Motor length[mm]
Mass[kg]
Winding resistance[Ohms / phase]
Inductance[mH/
Phase]
Rotor inertia[g-cm2]
Permissible inertia[g-cm2]
Closed-loop Stepping Driver and
Stepping Motor Package
Single shaft
CSA-BX42D2E400※ 1 1.6
0.23 53.0 0.29 1.5 3.2 40 400
CSA-BX42D4E 0.38 67.5 0.42 1.9 4.5 70 700
CSA-BX42D2E(1.6A)
0 2000 4000 6000 8000 10000
Frequency【pps】(400P/R)
Torque【N-m】
Input current【A】
0.40
0.30
0.20
0.10
0.00
4.0
3.0
2.0
1.0
0.0
0 300 600 900 1200 1500
Speed【r/min】
TorqueInput current
10
Motor specifications
20±0.5
15
1.6 5
L
5.8
φ38.1-0-0.03
φ6.35
-0-0.013
47.14
47.14
□56.4
4-φ4.5
12345678
Pin No.
CSA-BX56D SeriesStepping motorDimensions
Refer to chart below for motor length
・ Permissible thrust load to the shaft : 5.4N (0.54kgf)
・ Permissible radial load to the shaft : 50N (5kgf)
Speed and torque Specifications
2 phaseSingle shaft
Bipolar/Encoderoutput
CSA-BX56D3E(2.8A)
0 2000 4000 6000 8000 10000
Frequency【pps】
Torque【N-m】
Input current【A】
1.60
1.40
1.20
1.00
0.80
0.60
0.40
0.20
0.00
4.0
3.0
2.0
1.0
0.0
0 300 600 900 1200 1500
Speed【r/min】
(400P/R)
TorqueInput current
8
6
7 5
A
A
BB
Wiring diagramPin No. 1 2 3 4 5 6 7 8
Signal ENC_B ENC_A GND +5V_B
_A B A
※CAD Data (2D & 3D) download page http:/www.skcj.co.jp/plexmotion/english/download/
※Keep the load within permissible load value. Otherwise, it may cause the shaft to bend or break. Radial load value is measured at the top of the output shaft.
※1 Maximum resolution is 3,200P/R with resolution setting switch on driver
※Torque on graph shows pull out torque. ▲shows maximum starting frequency. ※Measurement conditions : DC24V input and 400P/R resolution, Open-loop stall detection mode. Load inertia 216g-cm2
Operating ambient temperature 0 to + 40 Deg.C. No freezingOperating ambient humidity 85% or less. No condensingStorage temperature -20 to 70 Deg.C. No freezingStorage humidity 85% or less. No condensing
Atmosphere No corrosive gas, no dust surroundings, no water and oil splash.
Improper motor operation may cause excessive temperature rising. Operate the motor keeping the motor surface temperature 70Deg. C or lower.
Model Shaft Item nameResolution
[P/R]※ 1
Input current
[A/phase]
Holding torque[N-m]
Motor length[mm]
Mass[kg]
Winding resistance[Ohms / phase]
Inductance[mH/
Phase]
Rotor inertia[g-cm2]
Permissible inertia[g-cm2]
Closed-loop Stepping Driver and
Stepping Motor Package
Single shaft
CSA-BX56D1E
400※ 1 2.8
0.44 56.5 0.51 0.85 2.4 153 1,530
CSA-BX56D3E 0.77 68.5 0.71 1.15 4.4 290 2,900
CSA-BX56D5E 1.40 91.5 1.10 1.75 6.9 513 5,130
CSA-BX56D1E(2.8A)
0 2000 4000 6000 8000 10000
Frequency【pps】
Torque【N-m】
Input current【A】
1.60
1.40
1.20
1.00
0.80
0.60
0.40
0.20
0.00
4.0
3.0
2.0
1.0
0.0
0 300 600 900 1200 1500
Speed【r/min】
(400P/R)
TorqueInput current
0 2000 4000 6000 8000 10000
Frequency【pps】
Torque【N-m】
Input current【A】
1.60
1.40
1.20
1.00
0.80
0.60
0.40
0.20
0.00
4.0
3.0
2.0
1.0
0.0
0 300 600 900 1200 1500
Speed【r/min】
(400P/R)
TorqueInput current
CSA-BX56D5E(2.8A)
11
CS
A-B
XS
erie
sC
SA
-BX
42
DS
erie
s Mo
tor
Driv
er
Lin
eu
pC
SA
-BX
56
DS
erie
s Mo
tor
Fe
atu
res
Clo
se
d-lo
op
Ste
pp
ing
Driv
er a
nd
Ste
pp
ing
Mo
tor P
ac
ka
ge
Before ordering product...The product described in this catalogue is designed and manufactured for use “in general industrial machinery”, including built in applica-tions such as the following 【 Suggested applications 】. Note the product warranty policy does not apply and is void when the product is used in the following【 None suggested applications 】.
【 Suggested applications 】General industrial machinery including built in applications such as automatic assembling machines, machining fixtures, inspection machines, factory automation machines.
【 None suggested applications】Applications that may significantly affect human lives or properties, such as safety devices, transportation equipment (including automobiles, automotive devices, aerospace and ships), medical devices, home-use electric or elec-tronic appliances.
■Product warranty.● Within one (1) year from the date of invoice ("Warranty Period"), product breakage, deformation, or defect ("Defects") by cause of Shi-
nano Kenshi, the product you purchased shall be repaired, or be replaced at no charge. This warranty excludes and does not cover any defects arising from or related to the following:
(1)Use other than【 Suggested applications 】 (2)Abuse and misuse. (3)Acts of God (Earthquake, lightning, fire or flood) (4)Negligence in observing specifications, applications, precaution of using, use conditions, drawings, other matters related to the
product, product (including optional parts) operation manuals or against other indications regarding safe use. (5) Unauthorized machining, repairs, modifications or disassembly. (6) Use with other manufactures’ devices. (7) Use beyond the product life. (8) Other than above, defects cannot be attributed to Shinano Kenshi.● After warranty period or out of warranty, any and all repairs, replacements and consumable replacements will be charged to users.● Shinano Kenshi is not liable for direct damages, loss of opportunities, special damages, incidental damages and other consequent dam-
ages or loss caused by production line stop of factory and factory facilities with using our products. Furthermore, even damages or loss by the causes attributable to Shinano Kenshi's product, Shinano Kenshi's liability in related to the warranty is limited to the cost of re-placing the product with the same or equivalent product of repairing product whichever is smaller.
■Notes● Product name, specifications, dimensions may change without notice for product improvement.● Products shown in this catalogue may be discontinued without prior notice.● Do not modify or machine the products. Contact sales agents or sales offices if modification or machining is required.● Select suitable product for your use condition and application. If any question, feel free to contact sales agents or sales offices.
Be sure to read the operation manual for safe operation before using. The product described in this catalogue
is designed and manufactured for the use of general industrial machinery.
Do not use the products for other than the suggested applications.
Safety precaution
Sales office & Sales agent
(81).268.(81).268.
Designed and manufactured by Shinano Kenshi Co., Ltd.
SKJP201705-BX00-XXXXIssued in May 2017 is registered trademark or trademark of Shinano Kenshi Co., Ltd. or its subsidiaries.
〒386-04981078 Kami-maruko, Ueda-shi, Nagano-ken, JAPANURL: http://www.plexmotion.com/english/E-mail: [email protected]