Upcoming Cold Projects
Distrigaz LNG Terminalin Boston, MA
Sabine Pass LNG
Confidential & Proprietary
-2-
Cheniere Energy Trial
• Insulation Incorporated: contractor
• Install on 36” line– 80mm Cryogel system vs 9.5” (2 layer FOAMGLAS system)
• Results– For large bore pipe and fittings: 80% faster install rate for Cryogel
– For small bore pipe and fittings: 10-20% faster install for Cryogel(note small bore applies when half sections are applied)
Confidential & Proprietary
Cryogel Installation Demo at theDistrigas LNG Terminal
Everett, MA
October, 2007
Confidential & Proprietary
-4-
Background Info On 1st Cryogel Installation by Suez LNG NA
• Between Friday, October 12 and Tuesday, October 16, crews from Zampell Insulation installed foil-faced Cryogel on a section of piping at the Distrigas LNG terminal in Everett, MA
Moored position of boat
Install location
LNG storage tanks
Liquid and vapor lines
Scope of work included two 26 ft pipe sections abutting sliding shoes:• 24” liquid transfer line
• 12” vapor return line12” line
24” line
Confidential & Proprietary
Installation
Confidential & Proprietary
-6-
Brush Pipe and Existing Vapor Stop with 90-66 Prior to 1st Piece
Photo courtesy Zampell Insulation
Confidential & Proprietary
-7-
Liquid Transfer Line Used 7 Layers (70 mm) Applied In 4 Pieces
Photo courtesy Zampell Insulation
Confidential & Proprietary
-8-
Every Vertical and Horizontal Seam Butyl Taped
Photo courtesy Zampell Insulation
Confidential & Proprietary
-9-
90-66 Application On Liquid Line Prior to 3rd Piece
Photo courtesy Zampell Insulation
Confidential & Proprietary
-10-
Installing 3rd Piece (Layers 5 and 6) On the Liquid Line
Photo courtesy Zampell Insulation
Confidential & Proprietary
-11-
Build Cryogel Up to Existing Vapor Stop Diameter At Each End
Cryogel diameter
Shoe diameter
10 inch Cryogel transition piece
Photo courtesy Zampell Insulation
Confidential & Proprietary
-12-
Vapor Stop From Existing Cellular Glass to Cryogel
Photo courtesy Zampell Insulation
Confidential & Proprietary
-13-
Finishing Up Liquid Line with Alumaguard
Photo courtesy Zampell Insulation
Confidential & Proprietary
-14-
Finished Aerogel Product On LNG and Vapor Lines
Photo courtesy Zampell Insulation
Confidential & Proprietary
IR Survey
Confidential & Proprietary
-16-
Predictions Match Observed Behavior for All Four Systems*
* Note that the IR camera used for this study (an Infracam SD from FLIR) does not compensate well for low-emissivity surfaces like Alumaguard. Therefore, although the relative temperature differences between observed surfaces are correct (particularly for surfaces imaged in the same frame), the absolute value of the temperature readings may not be accurate.
Freezingobserved Condensation
observed
Confidential & Proprietary
-17-
The Cryogel-Insulated Piping Performed As Designed
24” LNGline
HDfoamglas
shoes
12” vaporline
Concretepad
Shows extent of Cryogel insulated sections
Bare pipe
Confidential & Proprietary
-18-
70 mm Cryogel Matches Performance of 150 mm Cellular Glass
150 mm (6”) cellular glass70 mm (2.75”) Cryogel
Confidential & Proprietary
-19-
Foam Glass Expansion / Contraction Joints Are Cold Spots
Confidential & Proprietary
-20-
Other Trouble Spots Relate to Old (Original?) PUF
Confidential & Proprietary
-21-
Summary and Conclusions
• Despite some early delays re: the vapor stop specification and the most efficient cutting tools, the Cryogel system clearly offers productivity advantages
– Faster installation
– Ease-of-use in awkward or confined areas
– Elimination of expansion / contraction joints
• All the insulation systems near the dock behaved as expected, and showed no defects in either material or workmanship. These included:
– 3” HD foamglas on the pipe shoes
– 4” and 6” standard foamglas
– 2.8” (7 layers of 10 mm) Cryogel 10201-Z
• Note that the sections using 3” and 4” foamglas are clearly underinsulated
Confidential & Proprietary
Saudi Aramco Gas Project
Confidential & Proprietary
-23-
Uthmaniyah Gas Plant Saudi Arabia
Size: 8”
Fluid: NGL (C2+)
Temperature: -90 oF
Existing FOAMGLASS thickness: 150 mm.( Two layers of 75 mm, prefabricated pipe cover).
Cryogel Thickness: 60 mm
Cryogel install time: 15 minutes
Cryogel Advantages:
Reduction in the outside diameter of the insulated pipe thus less cladding material is used.
No fabrication required and less install time required.
Less accessories.
Confidential & Proprietary
-24-
Saudi Aramco Trial
Confidential & Proprietary
-25-
Saudi Aramco Trial
Confidential & Proprietary
-26-
Saudi Aramco Trial
Confidential & Proprietary
-27-
Saudi Aramco Trial
Confidential & Proprietary
-28-
Here you can see the spacesaving with used ofCryogel. 2x10mm.
Here its used normalInsulation.
Foamglass 50mm.
Ormen Lange Norway Trial
Confidential & Proprietary
-29-
Technip cryogenic PIP
• System qualified Bureau Veritas