Configuring EWA through SDCCN
1- Make sure the following parameters are set(OSS note 144864)
R/3 instance profile parameters as follows: stat/level = 1 rsdb/staton = 1
init<SID>.ora as follows: timed_statistics =true
2- Prerequisites(OSS note 91488):
- Make sure ST-PI 2005_1_640 is in at SPAM. (OSS note 116095)
- Make sure ST-A/PI 01G_R3_470 for R/3 and 01G_BCO640 for BW and
XI boxes are in place. (OSS note 69455)
- Make sure OSS1 works.
3- Deactivate SDCC and activate SDCCN(OSS note 763561):
- Delete AUTO_SESSION_MANAGER, SESS*, SASSM* jobs
- Go to SDCCN Utilities� Activate
YES
YES
YES
![Page 2: Configuring ewa through_sdccn_v1](https://reader036.vdocument.in/reader036/viewer/2022081820/5470bb20b4af9fb90a8b487e/html5/thumbnails/2.jpg)
![Page 3: Configuring ewa through_sdccn_v1](https://reader036.vdocument.in/reader036/viewer/2022081820/5470bb20b4af9fb90a8b487e/html5/thumbnails/3.jpg)
- Check if SDCC is deactivated. Goto SDCC and verify:
- Check if task processor in SDCCN is active: SDCCN� Goto�
Settings�Task Processor � Should be active as follows:
![Page 4: Configuring ewa through_sdccn_v1](https://reader036.vdocument.in/reader036/viewer/2022081820/5470bb20b4af9fb90a8b487e/html5/thumbnails/4.jpg)
4- Activating EWA in SDCCN (OSS note 207223)
- Refresh Service Definitions: SDCCN� Todo tab double click on execute
next to Service Preparation Check
![Page 5: Configuring ewa through_sdccn_v1](https://reader036.vdocument.in/reader036/viewer/2022081820/5470bb20b4af9fb90a8b487e/html5/thumbnails/5.jpg)
SAVE
![Page 6: Configuring ewa through_sdccn_v1](https://reader036.vdocument.in/reader036/viewer/2022081820/5470bb20b4af9fb90a8b487e/html5/thumbnails/6.jpg)
For 187939 click on icon then click on “Set Green” icon.
For 69455 click on and click on “Procedure after addon
implementation”
![Page 7: Configuring ewa through_sdccn_v1](https://reader036.vdocument.in/reader036/viewer/2022081820/5470bb20b4af9fb90a8b487e/html5/thumbnails/7.jpg)
![Page 8: Configuring ewa through_sdccn_v1](https://reader036.vdocument.in/reader036/viewer/2022081820/5470bb20b4af9fb90a8b487e/html5/thumbnails/8.jpg)
Confirm and make sure there are no more red marked OSS notes then
exit.
YES
- Setup parameters for EWA: SDCCN� Goto� Settings� Task Specific�
Session Data Collection�Data Request � Settings� Validate the
following:
![Page 9: Configuring ewa through_sdccn_v1](https://reader036.vdocument.in/reader036/viewer/2022081820/5470bb20b4af9fb90a8b487e/html5/thumbnails/9.jpg)
- Create a new RFC destination to Solution Manager: SDCCN� GoTo�
Settings� Task Specific � RFC Destination Settings click on �
Change �
![Page 10: Configuring ewa through_sdccn_v1](https://reader036.vdocument.in/reader036/viewer/2022081820/5470bb20b4af9fb90a8b487e/html5/thumbnails/10.jpg)
Add RFC Destination �
- Create a new task: SDCCN� Task � Create � Refresh Sessions �
![Page 11: Configuring ewa through_sdccn_v1](https://reader036.vdocument.in/reader036/viewer/2022081820/5470bb20b4af9fb90a8b487e/html5/thumbnails/11.jpg)
Click on and set the job as daily.
![Page 12: Configuring ewa through_sdccn_v1](https://reader036.vdocument.in/reader036/viewer/2022081820/5470bb20b4af9fb90a8b487e/html5/thumbnails/12.jpg)
Troubleshooting:
- Make sure SDCC_OSS RFC destination is working.