Item no 40INFORMATIONS TO DESIGN A CONTROL VALVELine Size -100 MMPipe Schedule -80Tag No.-ITEM NO. 40Service -STEAMState of the Flow Medium -STEAMName Of the Flow Medium -STEAMFlow Parameters :Min.Nor.Max.Flow Rate - (TPH/ M3/HR)0 TPH1.2 TPH2 TPHInlet Pressure (kg/cm2 / Bar g)0 BAR5.5 BAR6 BAROutlet Pressure (kg/cm2 / Bar g)0 BAR5 BAR5.5 BARPressure Drop (kg/cm2 / Bar g)00.5 BAR0.5 BARTemperature (degree C)250260270Design Pressure -6 BARDesign Temperature -260 DEG CBody Material -VENDOR TO SPECIFYBody Rating -VENDOR TO SPECIFYIBR Certification -REQUIREDuty - Modulating / ON-OFFMODULATINGEnd Connection -FLANGEActuator -Pneumatic / ElectricalPNEUMATICFor Pneumatic Actuator :Actuator Action -LINEARAir Fail Position -OPENPositioner -SMARTI/P Converter -INBUILDPosition Feedback Transmitter -4-20 mAHand Wheel -REQUIRELimit Switches -NOT REQUIREDFor Smart Positioner -HART / FF / PBHARTSolenoid Valve -NOT REQUIRED

item no 60INFORMATIONS TO DESIGN A CONTROL VALVELine Size -200 MMPipe Schedule -80Tag No.-ITEM NO. 60Service -STEAMState of the Flow Medium -STEAMName Of the Flow Medium -STEAMFlow Parameters :Min.Nor.Max.Flow Rate - (TPH/ M3/HR)0 TPH5.0 TPH6 TPHInlet Pressure (kg/cm2 / Bar g)0 BAR5.5 BAR6 BAROutlet Pressure (kg/cm2 / Bar g)0 BAR5 BAR5.5 BARPressure Drop (kg/cm2 / Bar g)0 BAR0.5 BAR0.5 BARTemperature (degree C)250260270Design Pressure -6 BARDesign Temperature -260 DEG CBody Material -VENDOR TO SPECIFYBody Rating -VENDOR TO SPECIFYIBR Certification -REQUIREDuty - Modulating / ON-OFFMODULATINGEnd Connection -FLANGEActuator -Pneumatic / ElectricalPNEUMATICFor Pneumatic Actuator :Actuator Action -LINEARAir Fail Position -OPENPositioner -SMARTI/P Converter -INBUILDPosition Feedback Transmitter -4-20 mAHand Wheel -REQUIRELimit Switches -NOT REQUIREDFor Smart Positioner -HART / FF / PBHARTSolenoid Valve -NOT REQUIRED

Item no 50INFORMATIONS TO DESIGN A CONTROL VALVELine Size -150 MMPipe Schedule -80Tag No.-ITEM NO. 50Service -STEAMState of the Flow Medium -STEAMName Of the Flow Medium -STEAMFlow Parameters :Min.Nor.Max.Flow Rate - (TPH/ M3/HR)0 TPH3 TPH3.6 TPHInlet Pressure (kg/cm2 / Bar g)0 BAR5.5 BAR6 BAROutlet Pressure (kg/cm2 / Bar g)0 BAR5 BAR5.5 BARPressure Drop (kg/cm2 / Bar g)0 BAR0.5 BAR0.5 BARTemperature (degree C)250260270Design Pressure -6 BARDesign Temperature -260 DEG CBody Material -VENDOR TO SPECIFYBody Rating -VENDOR TO SPECIFYIBR Certification -REQUIREDuty - Modulating / ON-OFFMODULATINGEnd Connection -FLANGEActuator -Pneumatic / ElectricalPNEUMATICFor Pneumatic Actuator :Actuator Action -LINEARAir Fail Position -OPENPositioner -SMARTI/P Converter -INBUILDPosition Feedback Transmitter -4-20 mAHand Wheel -REQUIRELimit Switches -NOT REQUIREDFor Smart Positioner -HART / FF / PBHARTSolenoid Valve -NOT REQUIRED

item no 70INFORMATIONS TO DESIGN A CONTROL VALVELine Size -150 MMPipe Schedule -40Tag No.-ITEM NO. 70Service -OXYGENState of the Flow Medium -OXYGENName Of the Flow Medium -OXYGENFlow Parameters :Min.Nor.Max.Flow Rate - (TPH/ M3/HR)0 M3/HR2500 M3/HR3200 M3/HRInlet Pressure (kg/cm2 / Bar g)0 BAR2.5 BAR3 BAROutlet Pressure (kg/cm2 / Bar g)0 BAR2.3 BAR2.8 BARPressure Drop (kg/cm2 / Bar g)0 BAR0.2 BAR0.2 BARTemperature (degree C)253032Design Pressure -3 BARDesign Temperature -30 DEG CBody Material -VENDOR TO SPECIFYBody Rating -VENDOR TO SPECIFYIBR Certification -REQUIREDuty - Modulating / ON-OFFMODULATINGEnd Connection -FLANGEActuator -Pneumatic / ElectricalPNEUMATICFor Pneumatic Actuator :Actuator Action -LINEARAir Fail Position -OPENPositioner -SMARTI/P Converter -INBUILDPosition Feedback Transmitter -4-20 mAHand Wheel -REQUIRELimit Switches -NOT REQUIREDFor Smart Positioner -HART / FF / PBHARTSolenoid Valve -NOT REQUIRED


Top Related