Midea Is Your Idea
Midea Air Conditioners
2007
Commercial Aircon System 50HZ
GD Midea Commercial Air-conditioning Equipment Co., Ltd.
Add: Midea Industrial City, Shunde, Foshan, Guangdong, 528311, P.R.China
Tel: +86-757-26339642 Fax: +86-757-26339337
E-mail: [email protected]
Http: //www.midea.com.cn
Http: //www.mdvchina.com (customer service)
N433
E U ROV EN TCERTIFIED PERFORMANCE
TUV Rheiniand Group Production inspected
L I S T E D
TUV Rheiniand
gepruftesicherheit
NRTL/CISO 14001: 1996
Certificate No.:CC1417
068
CERTIFIEDCOMPANYCERTIFIED
COMPANY
ISO 9001 : 2000Certificate No.: CC 454
068
I NTERN AT IONAL CONFORMI TY C ERT I F ICAT I
ONPR
OGRA
MSAUDI ARABIAN STANDARDS ORGANIZAT
ION
Midea produced its first Air
Conditioner in 1984. Currently
we are the industry leader for Air
conditioner manufacturing and
export . Midea has been
exporting Air Conditioners for the
last 16 years, and during this
time has cultivated strong
partnerships with hundreds of
overseas companies.
Our vertically integrated supply
chain al lows us to achieve
maximum efficiency in production
and product development.
We provide Global technical
training and a comprehensive
online customer service. All
of our customers from over
110 countries and regions
receive top quality service at
all times.
Midea Creates A Better Life
geprufteSicherheit
..
1 2
The year of 1999 has witnessed
Midea's entry into the field of
commercial air conditioner. The
leading-edged technology, state-of-
art assembly lines, and years' of
experience in air conditioner field have
made Midea as the leader in the field
of commercial air conditioner in China.
Nowadays, Midea can offer the
fullest range of commercial air
conditioner in China. It consists
of Multi Digital Variable System:
Digital scroll A/C system, Inverter
commercial A/C system; Light
Chiller System: Mini air-cooled
chiller system, Modular air-cooled
chiller system, Water-cooled
Packaged unit, Heating water
system; Commercial Chiller
System: Screw chiller system,
Centrifugal chiller system.
Intelligent Manager is an integrated building management system(BMS) that uses our independent, high-speed
multi-transmission method. It has a centralized controller function that can perform high-speed centralized control
of our commercial A/C for buildings.
MDV system has various control solutions: Individual control, Group control, Network control, etc.
1 computer can monitor max 16 central controllers.
1 central centroller can monitor max 64 indoor units.
1 computer can monitor max 1024 indoor units.
Free combination, wide range5 basic modules, which can be freely assembled.
2HP increments of capacity range, which meets customers' needs accurately;
Maximum capacity is 64HP.
3 4
Friendly Refrigerant, save energy and protect environment
Good performance of cooling & heating.
The component of the R410A is close to azeotropy, with little change of the component
structure, the capability will not decrease during the recharge period.
Do not contain the element Chlorine, protect the ozonosphere
Feature of R410A system
Basic modules 5 basic modules: 8HP, 10HP, 12HP, 14HP, 16HP
2HP increments of capacity
Intelligent Built-in Manager SystemFull Range of R410A Digital Scroll A/C System
R410A
Max=64
Central controller
Max=64
Max=16
Max=32
Lonwork
LON busover ethernet
R
BMS
Touch controller
Built-in manager system
Fire alarm Security
*Elevator*Pump*Lighting ...etc.
Power supply facility
Remote controller
R410A
Basic modules
50-64HP
8-16HP
18-32HP
34-48HP
Group setting, simple and efficient.
One group consists of on-line A/Cs in different
Central controllers, maximum 1024 units.
One system can be set by 16 groups to manage
a huge A/C system. The
group setting can control
each on-line unit, unionize
them to be On / Off or
change the parameters. It's
so convenient and easy.
Schedule setting, no need to worry during the operation of A/C
With the advanced Schedule setting mode, the
PC can easily manage the daily work of A/C. The
system can set the weekly plan of A/C and operate
automatically in cycle.
Windows version
Operate directly on Windows interface; friendlier
interface makes its applicable range much wider.
Main functions includes load calculation, multi-
split and chilled water system selection, explicit
quotation table output, hydraulic calculation,
capacity inquire with changeable outdoor
environment (for multi-split) or nonstandard
working criteria (for chiller), etc.
Update with product change.
CAD version Two versions each compatible with AutoCAD 2000/2002 and AutoCAD 2004/2005
Professional software that helps engineers design project easily, quickly and conveniently. Main
functions include load calculation, equipment selection, pipeline setting, system figure configuration,
quotation table automatic output, refrigerant volume calculation, wiring and installation diagram
output, etc.
Update with product change
5 6
Model selection softwareIntelligent Built-in Manager System
Independent Calculating System
Coverter
Digital Ammeter
CCM
Built-in manager system
CCM
Max=64
POWERPOWERPOWER
POWER
Independent calculation Report
Independent calculation and output with report, easy to know the charge of the A/C.
DC(AC) Inverter Multi AC Inverter Multi Eco
Multi Series
Split Wall-Mounted
Four-Way Cassette
Duct
2007 Midea Commercial A/C Model Line Up
[ D ] Digital Scroll A/C System
[ M ] Multi Variable A/C System
[ H ] Multi System
[ V ] Inverter A/C System (DC/AC)
25.2-180kW28-84kW14kW10kW
25.2-180kW16-18kW12-14kW8kW
26kW12kW
[ R ] Heating Water System
Accessories
35kW17.5kW9kW7kW
Multi Star
9 10
Four-cassette type(12.5kW)
Duct type(slim)(6kW)
Duct type(13kW)
High static pressure Duct type(13kW)
Four-cassette type(6kW)
53-62
63-6
768
-76
29-43
44-49
50-52
R410A R407C R22
R410A R22
R407C R22
R410A R407C R22
R407C R22
R410A R410AR410A
R410A R410A
R410A R407C
R410A R407C
Four-way cassette One-way cassette (compact)
High static
pressure duct
Wall-mountedFloor standing
Four-way cassette One-way cassette (compact)
High static
pressure duct
Wall-mountedFloor standing
Ceiling & Floor
Ceiling & FloorDuctLow static
pressure duct
DuctLow static
pressure duct
R22
Heat Recovery Ventilator Auxiliary Electric Heater Auxiliary Electric Heater
Long pipe, wide height difference
No electromagnetic Disturbance
Operation Principle Of Digital Scroll Compressor
150m
50m
15m
the max.pipe length between indoor unit and outdoor unit
the max.height difference between indoor unit and outdoor unit
the max.height difference between indoor units
Advanced Oil Return Technology
Accurate Temperature Control
Constant T emperature
Temperature control accuracy of MDV: *0.5*
Temperature control accuracy of ordinary air conditioner: *3*
(Time)
Digital Scroll A/C System
33 34
The digital scroll compressor which utilizes the axial
compliant sealing technology precisely adjust the axial
moving range of the stator scroll pan. And there is an
additional connecting by-pass between the suction inlet
and the pressure bore at the floating sealing point of
axial stator.
When the PWM solenoid valve is open, the pressure in
the pressure bore is released. The pressure in the
compression bore is higher than that top of the stator,
then the stator axis of the compressor will move upward
a little. So high pressure bore and low pressure inlet is
connected and the unloading is achieved.
When the PWM solenoid valve is closed, two stators
engaged. Then the airproof and loading is achieved. The
compressor can adjust the ratio of ONs to OFFs freely
to control the refrigerant output of the compressor.
•
•
•
MDV Digital Scroll System causes no
electromagnetic disturbance, since the loading
and unloading of compressor are merely
mechanical movements. This special feature
makes the Digital Scroll System applicable to
telecommunication companies, power stations,
and all kinds of precise science labs.
•
A
Electromagnetic Comparison Between Digital And Inverter
0 1 2 3 4 5
5 th7 th
11 th13 th17 th19 th
E
M
W
Inverter EMC Standard Digital
Precise Science Lab CommunicationComputer Lab
TV & Radio Receiver Station
The Digital Scroll Compressor is in the state of loading or unloading. In the loading state, the full speed
operation of the compressor motor ensures the refrigerant has enough power to bring the oil back to the
compressor. In the unloading state, there is no oil moving out of the compressor since there is no refrigerant
output, the inertia of the refrigerant can also bring some oil back to the compressor.
•
Combining the electronic control and the mechanical control, the oil level controller keeps an appropriate
oil level in the compressor crankcase. Equipped with alarm system, it is applicable to both low-pressure
& high pressure oil cycling system.
•
Compared with the traditional
central air conditioning system,
MDV System can reach a 0.5
Degree Centigrade accuracy.
•
Digital scroll system is the only system that is free of oil separator
and oil recycling equipment. In the loading status, the speed
of the refrigerant is enough to move oil back to the compressor.In
the unloading status, no refrigerant pump out, no oil out of
compressor.
•
150m
50m15m
Outdoor Unit
Cooling & Heating
Outdoor Unit
Digital Scroll A/C System
Outdoor Unit
35 36
8
10
12
14
16
8+10
10+10
10+12
10+14
10+16
12+16
14+16
16+16
10x2+14
10x2+16
10+12+16
10+14+16
10+16x2
12+16x2
14+16x2
16x3
12x3+14
12x3+16
12x2+14+16
12x2+16x2
10+16x3
12+16x3
14+16x3
16x4
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48
50
52
54
56
58
60
62
64
13
16
16
16
20
20
20
20
20
20
20
32
32
32
32
32
40
40
40
40
40
50
50
50
50
50
64
64
64
MDV-D252W/CS(N2)(N1)
MDV-D280W/CS(N2)(N1)
MDV-D335W/CS(N2)(N1)
MDV-D400W/CS(N2)(N1)
MDV-D450W/CS(N2)(N1)
MDV-D532W/CS(N2)(N1)
MDV-D560W/CS(N2)(N1)
MDV-D615W/CS(N2)(N1)
MDV-D680W/CS(N2)(N1)
MDV-D730W/CS(N2)(N1)
MDV-D785W/CS(N2)(N1)
MDV-D850W/CS(N2)(N1)
MDV-D900W/CS(N2)(N1)
MDV-D960W/CS(N2)(N1)
MDV-D1010W/CS(N2)(N1)
MDV-D1065W/CS(N2)(N1)
MDV-D1130W/CS(N2)(N1)
MDV-D1180W/CS(N2)(N1)
MDV-D1235W/CS(N2)(N1)
MDV-D1300W/CS(N2)(N1)
MDV-D1350W/CS(N2)(N1)
MDV-D1405W/CS(N2)(N1)
MDV-D1455W/CS(N2)(N1)
MDV-D1520W/CS(N2)(N1)
MDV-D1570W/CS(N2)(N1)
MDV-D1630W/CS(N2)(N1)
MDV-D1685W/CS(N2)(N1)
MDV-D1750W/CS(N2)(N1)
MDV-D1800W/CS(N2)(N1)
Capacity(HP) Model Combination Indoor unit connected
Remarks: 1.The above specifications are subject to change without prior notice for product improvement. 2.The noise levels given in the table reflect the levels in anechoic chamber.
R410A
R407C
R22
28.031.5
25.227.0
380,50,3
980x1630x8001040x1780x840
1751550
1000058
245260
1-drive-1314/28/28
SystemMatch Configuration
Model
Voltage,Frequence,Phase
Air Flow VolumeNoise Level
Net WxHxDPacking WxHxD
NetGross
kWkW
m3/hdB(A)
mmmm
kgkg
V~,Hz,Ph
Capacity
Performance
Dimension
Weight
Piping Connection
CoolingHeatingElectrical Data
Max Length of pipeMax Height Difference Between indoor units Between indoor units and outdoor unit
MaxQty per 20'/40'/40'HQ
IMDV-D252W/CSN1 IMDV-D280W/CSN1 IMDV-D335W/CSN1 IMDV-D400W/CSN1 IMDV-D450W/CSN1
Pieces1-drive-16
33.535.0
40.043.0
396416
1400060
1380x1630x8301440x1800x860
45.047.0
1-drive-208/16/16
SystemMatch Configuration
Model
Voltage,Frequence,Phase
Air Flow VolumeNoise Level
Net WxHxDPacking WxHxD
NetGross
kWkW
m3/hdB(A)
mmmm
kgkg
V~,Hz,Ph
Capacity
Performance
Dimension
Weight
Piping Connection
CoolingHeatingElectrical Data
Max Length of pipeMax Height Difference Between indoor units Between indoor units and outdoor unit
MaxQty per 20'/40'/40'HQ
IMDV-D252W/CS(N2) IMDV-D280W/CS(N2) IMDV-D335W/CS(N2) IMDV-D400W/CS(N2) IMDV-D450W/CS(N2)
Pieces
45.047.0
25.227.0
380,50,3
1380x1630x8301440x1800x860
1501550
1400060
327347
1-drive-138/16/16
28.031.5
1-drive-16
33.535.0
40.043.0
396416
1-drive-20
Indoor UnitUnit:X100W
Cooling & Heating
Outdoor Unit
Remarks: 1.The above specifications are subject to change without prior notice for product improvement. 2.The noise levels given in the table reflect the levels in anechoic chamber.
Outdoor Unit
Digital Scroll A/C System
Model Refrigerant Capacity
R410A R407C R22
R407C R22
R410A
R410A R407C R22
R410A R407C R22
R410A R407C R22
280
R410A R407C R22
R410A R407C R22
R410A R407C R22
R410A R407C R22
R410A R407C R22
R410A R407C R22
R410A R407C R22
R410A R407C R22
37 38
R407C
R22
Four-way cassette
Four-way cassette (compact)
High static pressure duct
One-way cassette
One-way cassette(compact)
Wall-mounted(compact)
Wall-mounted
High static pressure duct
Duct
Low Static PressureDuct
Floor Standing
Concealed Floor Standing
The Digital Scroll A/C System and Inverter Commercial A/C System have the same specification of indoor unit.
Ceiling & floor
R410A
997x1920x8801105x2120x1034
1000058
245260
IMDV-D100W/(S)N1 IMDV-D140W/SN1 IMDV-D280W/BSN1
28.031.5
1-drive-1610/20/20
1751550
Model
SystemMatch Configuration
Voltage,Frequence,Phase
Air Flow VolumeNoise Level
Net WxHxDPacking WxHxD
NetGross
kWkW
m3/hdB(A)
mmmm
kgkg
V~,Hz,Ph
Capacity
Performance
Dimension
Weight
Piping Connection
CoolingHeatingElectrical Data
Max Length of pipeMax Height Difference Between indoor units
Between indoor units and outdoor unit
MaxQty per 20'/40'/40'HQ Pieces
10.011.0
990x960x3601120x1090x435
60820
500054
101106
1-drive-650/100/100
14.016.0
220-240,50,1(380,50,3)
1-drive-830/62/62
600055
940x1245x3401058x1377x435
110125
380,50,3
IMDV-D100W/SN2 IMDV-D100W/(N2) IMDV-D140W/S(N2) IMDV-D280W/BS(N2) IMDV-D560W/BS(N2) IMDV-D840W/BS(N2)
14.016.0
380,50,3
1-drive-8
10.011.0
380,50,3
990x960x3601120x1090x435
60820
500054
101106
1-drive-650/100/100
SystemMatch Configuration
Model
Voltage,Frequence,Phase
Air Flow VolumeNoise Level
Net WxHxDPacking WxHxD
NetGross
kWkW
m3/hdB(A)
mmmm
kgkg
V~,Hz,Ph
Capacity
Performance
Dimension
Weight
Piping Connection
CoolingHeatingElectrical Data
Max Length of pipeMax Height Difference Between indoor units
Between indoor units and outdoor unit
MaxQty per 20'/40'/40'HQ
500054
Pieces
220-240,50,1
997x1920x8801105x2120x1034
1000058
245260
28.031.5
1-drive-1610/20/20
1501550
56.064.0
2000060
1992x1920x8802110x2120x1034
520525
1-drive-204/10/10
84.095.0
2987x1920x8803105x2120x1034
3000062
780785
1-drive-322/6/6
Remarks: 1.The above specifications are subject to change without prior notice for product improvement. 2.The noise levels given in the table reflect the levels in anechoic chamber.
Indoor Unit (Q4)
Cooling & Heating
Digital Scroll A/C System
Indoor Unit (Q1)
Remarks: 1.The above specifications are subject to change without prior notice for product improvement. 2.The noise levels given in the table reflect the levels in anechoic chamber.
Indoor Unit (T3)
Indoor Unit (T2)
39 40
Model
Voltage,Frequence,Phase
Air Flow VolumeNoise Level
Net WxHxD BodyPanel
Packing WxHxD Body Panel
Net Body/PanelGross Body/PanelQty per 20'/40'/40'HQ Indoor
kWkW
m3/hdB(A)
mmmmmmmm
kgkg
Pieces
V~,Hz,Ph
78036
2.83.2
580x254x580650x30x650795x340x745715x115x715
220-240,50,1
22/329/5
110/245/252
3.64.0
4.55.0
Capacity
Performance
Dimension
Weight
CoolingHeatingElectrical Data
IMDV-D28Q4/ N1-A IMDV-D36Q4/ N1-A IMDV-D45Q4/ N1-AIMDV-D28Q4/(N2)-A IMDV-D36Q4/(N2)-A IMDV-D45Q4/(N2)-A IMDV-D28Q4/(N2) IMDV-D36Q4/(N2)
870
2.83.2
840x240x840950x40x950955x255x955
1030x145x1030
25/632/11
72/145/168
3.64.0
Model
Voltage,Frequence,Phase
Air Flow VolumeNoise Level
Net WxHxD BodyPanel
Packing WxHxD Body Panel
Net Body/PanelGross Body/PanelQty per 20'/40'/40'HQ Indoor
kWkW
m3/hdB(A)
mmmmmmmm
kgkg
Pieces
V~,Hz,Ph
105038
840x240x840950x40x950955x255x955
1030x145x1030
220-240,50,1
28/634/11
72/145/168
4.55.0
5.66.3
Capacity
Performance
Dimension
Weight
CoolingHeatingElectrical Data
IMDV-D56Q4/N1 IMDV-D71Q4/N1 IMDV-D80Q4/N1 IMDV-D90Q4/N1 IMDV-D112Q4/N1 IMDV-D45Q4/(N2) IMDV-D56Q4/(N2) IMDV-D71Q4/(N2) IMDV-D80Q4/(N2) IMDV-D90Q4/(N2) IMDV-D112Q4/(N2)
7.18.0
42
8.09.0
9.010.0
840x310x840
955x325x955
160044
35/641/11
56/126/144
11.212.5
Model
Voltage,Frequence,Phase
Air Flow VolumeNoise Level
Net Body/PanelGross Body/PanelQty per 20'/40'/40'HQ Indoor
2.83.2
220-240,50,1
850x235x4001050x18x4701080x310x4601120x172x540
47035
23/427/7
115/238/268
kWkW
m3/hdB(A)
kgkg
Pieces
V~,Hz,Ph
Capacity
Performance
Dimension
Weight
CoolingHeatingElectrical Data
Net WxHxD BodyPanel
Packing WxHxD Body Panel
mmmmmmmm
3.64.0
50036
IMDV-D28Q1/B(N2) IMDV-D36Q1/B(N2) IMDV-D45Q1/B(N2) IMDV-D56Q1/B(N2) IMDV-D71Q1/B(N2)
31/938/12
69/145/165
4.55.0
1200x198x6551420x10x7551380x265x7751500x110x870
78042
5.66.3
7.18.0
1080
IMDV-D28Q1/BN1 IMDV-D36Q1/BN1 IMDV-D45Q1/BN1 IMDV-D56Q1/BN1 IMDV-D71Q1/BN1
Model
Voltage,Frequence,Phase
Air Flow VolumeExternal static pressure Noise Level
Net WxHxDPacking WxHxD
NetGrossQty per 20'/40'/40'HQ Indoor
kWkW
m3/hPa
dB(A)
mmmm
kgkg
Pieces
V~,Hz,Ph
5801034
2.22.6
955x210x3851114x277x469
1519
214/437/480
2.83.2
35
3.64.0
Capacity
Performance
Dimension
Weight
CoolingHeatingElectrical Data
IMDV-D22T3/N1 IMDV-D28T3/N1 IMDV-D36T3/N1 IMDV-D45T3/N1 IMDV-D56T3/N1 IMDV-D22T3/(N2) IMDV-D28T3/(N2) IMDV-D36T3/(N2) IMDV-D45T3/(N2) IMDV-D56T3/(N2)
220-240,50,1
4.55.0
1301x210x3851459x277x469
1822
164/315/391
950
37
5.66.3
2.83.2
35
3.64.0
2.22.6
Model
Voltage,Frequence,Phase
Air Flow VolumeExternal static pressureNoise Level
Net WxHxDPacking WxHxD
NetGrossQty per 20'/40'/40'HQ Indoor
kWkW
m3/hPa
dB(A)
mmmm
kgkg
Pieces
V~,Hz,Ph 220-240,50,1
Capacity
Performance
Dimension
Weight
CoolingHeatingElectrical Data
800x320x550930x420x755
2634
61/134/164
7504034
IMDV-D22T2/N1 IMDV-D28T2/N1 IMDV-D36T2/N1 IMDV-D45T2/N1-A3 IMDV-D56T2/N1-A3IMDV-D22T2/(N2) IMDV-D28T2/(N2) IMDV-D36T2/(N2) IMDV-D45T2/(N2)-A3 IMDV-D56T2/(N2)-A3
4.55.0
1000x298x8001200x370x930
1160
38
4654
60/140/164
5.66.3
7.18.0
14604042
4755
60/140/164
8.09.0
Model
Voltage,Frequence,Phase
Air Flow VolumeExternal static pressureNoise Level
Net WxHxDPacking WxHxD
NetGrossQty per 20'/40'/40'HQ Indoor
kWkW
m3/hPa
dB(A)
mmmm
kgkg
Pieces
V~,Hz,Ph 220-240,50,1
Capacity
Performance
Dimension
Weight
CoolingHeatingElectrical Data
1000x298x8001200x370x930
IMDV-D71T2/N1-A3 IMDV-D80T2/N1-A3 IMDV-D90T2/N1-A3 IMDV-D112T2/N1-A3 IMDV-D140T2/N1-A3 IMDV-D280T2/N1 IMDV-D71T2/(N2)-A3 IMDV-D80T2/(N2)-A3 IMDV-D90T2/(N2)-A3 IMDV-D112T2/(N2)-A3 IMDV-D140T2/(N2)-A3 IMDV-D280T2/(N2)
9.010.0
1350x298x8001555x370x930
20707044
6070
48/100/112
11.212.5
14.016.0
2400
46
28.031.0
1350x450x7601600x700x1010
44009649
99109
22/48/48
Digital Scroll A/C System
Indoor Unit (F)Indoor Unit (T1)
Indoor Unit (T1)
Cooling & Heating
41 42
Indoor Unit (F)
Remarks: 1.The above specifications are subject to change without prior notice for product improvement. 2.The noise levels given in the table reflect the levels in anechoic chamber.
Cooling & Heating
Indoor Unit (DL)
Remarks: 1.The above specifications are subject to change without prior notice for product improvement. 2.The noise levels given in the table reflect the levels in anechoic chamber.
80036
3.64.0
995x660x1981080x740x290
220-240,50,1
3037
128/270/300
7.18.0
100040
4.55.0
5.66.3
38
Model
Voltage,Frequence,Phase
Air Flow VolumeNoise Level
Net WxHxDPacking WxHxD
NetGrossQty per 20'/40'/40'HQ Indoor
kWkW
m3/hdB(A)
mmmm
kgkg
Pieces
V~,Hz,Ph
Capacity
Performance
Dimension
Weight
CoolingHeatingElectrical Data
IMDV-D36DL/N1-B IMDV-D45DL/N1-B IMDV-D56DL/N1-B IMDV-D71DL/N1-B IMDV-D80DL/N1-B IMDV-D90DL/N1-B IMDV-D112DL/N1-B IMDV-D140DL/N1-BIMDV-D36DL/(N2)-B IMDV-D45DL/(N2)-B IMDV-D56DL/(N2)-B IMDV-D71DL/(N2)-B IMDV-D80DL/(N2)-B IMDV-D90DL/(N2)-B IMDV-D112DL/(N2)-B IMDV-D140DL/(N2)-B
120041
8.09.0
9.010.0
1400
1285x660x1981365x740x290
3442
99/203/228
11.212.5
180042
14.016.0
2000
1670x680x2401760x760x330
5262
72/153/168
Model
Voltage,Frequence,Phase
Air Flow VolumeExternal static pressureNoise Level
Net WxHxDPacking WxHxD
NetGrossQty per 20'/40'/40'HQ Indoor
kWkW
m3/hPa
dB(A)
mmmm
kgkg
Pieces
V~,Hz,Ph
11.212.5
14.016.0
28.031.5
5000
50
1350x450x7601600x700x1010
98108
22/48/48
Capacity
Performance
Dimension
Weight
CoolingHeatingElectrical Data
IMDV-D71T1/(N2) IMDV-D80T1/(N2) IMDV-D90T1/(N2) IMDV-D112T1/(N2) IMDV-D140T1/(N2) IMDV-D280T1/(N2)
8.09.0
9.010.0
2200
47
1200x380x6601425x473x775
6270
60/123/123
130019644
7.18.0
850x380x6601075x473x775
220-240,50,1
4955
81/166/166
IMDV-D71T1/N1 IMDV-D80T1/N1 IMDV-D90T1/N1 IMDV-D112T1/N1 IMDV-D140T1/N1 IMDV-D280T1/N1
4.55.0
Model
Voltage,Frequence,Phase
Air Flow VolumeExternal static pressureNoise Level
Net WxHxDPacking WxHxD
NetGrossQty per 20'/40'/40'HQ Indoor
kWkW
m3/hPa
dB(A)
mmmm
kgkg
Pieces
V~,Hz,Ph 220-240,50,1
Capacity
Performance
Dimension
Weight
CoolingHeatingElectrical Data
1000x298x8001200x370x930
3845
60/140/164
14007038
IMDV-D45T1/(N2)-A3 IMDV-D56T1/(N2)-A3 IMDV-D71T1/(N2)-A3 IMDV-D80T1/(N2)-A3 IMDV-D90T1/(N2)-A3 IMDV-D112T1/(N2)-A3 IMDV-D140T1/(N2)-A
5.66.3
7.18.0
1550
42
4047
8.09.0
9.010.0
215010044
5059
48/100/112
1350x298x8001555x370x930
11.212.5
14.016.0
250015046
7282
36/84/98
1350x320x8001555x440x930
IMDV-D45T1/N1-A3 IMDV-D56T1/N1-A3 IMDV-D71T1/N1-A3 IMDV-D80T1/N1-A3 IMDV-D90T1/N1-A3 IMDV-D112T1/N1-A3 IMDV-D140T1/N1-A
42035
2.22.6
1000x626x2201145x810x285
220-240,50,1
3842
80/168/252
2.83.2
3.64.0
62037
Model
Voltage,Frequence,Phase
Air Flow VolumeNoise Level
Net WxHxDPacking WxHxD
NetGrossQty per 20'/40'/40'HQ Indoor
kWkW
m3/hdB(A)
mmmm
kgkg
Pieces
V~,Hz,Ph
Capacity
Performance
Dimension
Weight
CoolingHeatingElectrical Data
IMDV-D22F/N1 IMDV-D28F/N1 IMDV-D36F/N1 IMDV-D45F/N1 IMDV-D56F/N1 IMDV-D71F/N1 IMDV-D80F/N1 IMDV-D22F/(N2) IMDV-D28F/(N2) IMDV-D36F/(N2) IMDV-D45F/(N2) IMDV-D56F/(N2) IMDV-D71F/(N2) IMDV-D80F/(N2)
4.55.0
8.09.0
490
1200x626x2201335x810x285
4347
68/138/216
5.66.3
85039
1500x626x2201645x810x285
5560
54/114/171
95040
7.18.0
105042
42035
2.22.6
750x545x212835x630x265
220-240,50,1
3539
91/182/282
2.83.2
3.64.0
62037
Model
Voltage,Frequence,Phase
Air Flow VolumeNoise Level
Net WxHxDPacking WxHxD
NetGrossQty per 20'/40'/40'HQ Indoor
kWkW
m3/hdB(A)
mmmm
kgkg
Pieces
V~,Hz,Ph
Capacity
Performance
Dimension
Weight
CoolingHeatingElectrical Data
IMDV-D22F/N1-A IMDV-D28F/N1-A IMDV-D36F/N1-A IMDV-D45F/N1-A IMDV-D56F/N1-A IMDV-D71F/N1-A IMDV-D80F/N1-A IMDV-D22F/(N2)-A IMDV-D28F/(N2)-A IMDV-D36F/(N2)-A IMDV-D45F/(N2)-A IMDV-D56F/(N2)-A IMDV-D71F/(N2)-A IMDV-D80F/(N2)-A
4.55.0
8.09.0
490
950x545x2121035x630x265
3944
73/155/236
5.66.3
85039
1250x545x2121335x630x265
5055
59/134/192
95040
7.18.0
105042
Digital Scroll A/C System
Cooling & Heating
Indoor Unit (G)
Indoor Unit (G)
Remarks: 1.The above specifications are subject to change without prior notice for product improvement. 2.The noise levels given in the table reflect the levels in anechoic chamber.
43
Inverter A/C System(DC/AC)
[ V ] Series
58034
2.22.5
790x265x195875x375x285
220-240,50,1
911
312/668/780
2.83.2
3.64.0
85037
920x292x2251015x368x295
1315
288/578/653
Model
Voltage,Frequence,Phase
Air Flow VolumeNoise Level
Net WxHxDPacking WxHxD
NetGrossQty per 20'/40'/40'HQ Indoor
kWkW
m3/hdB(A)
mmmm
kgkg
Pieces
V~,Hz,Ph
Capacity
Performance
Dimension
Weight
CoolingHeatingElectrical Data
IMDV-D22G/N1-E IMDV-D28G/N1-E IMDV-D36G/N1-E IMDV-D45G/N1-E IMDV-D56G/N1-E IMDV-D22G/(N2)-E IMDV-D28G/(N2)-E IMDV-D36G/(N2)-E IMDV-D45G/(N2)-E IMDV-D56G/(N2)-E
4.55.0
5.66.3
56036
2.22.5
880x275x1981000x420x295
220-240,50,1
1114
252/512/576
2.83.2
3.64.0
67046
1080x330x2221315x445x320
1723
151/324/384
Model
Voltage,Frequence,Phase
Air Flow VolumeNoise Level
Net WxHxDPacking WxHxD
NetGrossQty per 20'/40'/40'HQ Indoor
kWkW
m3/hdB(A)
mmmm
kgkg
Pieces
V~,Hz,Ph
Capacity
Performance
Dimension
Weight
CoolingHeatingElectrical Data
IMDV-D22G/N1-A IMDV-D28G/N1-A IMDV-D36G/N1-A IMDV-D45G/N1-A IMDV-D56G/N1-A IMDV-D22G/(N2)-A IMDV-D28G/(N2)-A IMDV-D36G/(N2)-A IMDV-D45G/(N2)-A IMDV-D56G/(N2)-A
4.55.0
5.66.3