2
Careully read all instructions beore operating the
Kambrook CaptivG3Lit Cyclonic Bagless Vacuum
or the rst time and save or uture reerence.
To protect against electric shock, do not immerse
the vacuum, cord or plug in water or any otherliquid.
Ensure that the power source to be used is the
same as the voltage requirements o the product.
Always switch vacuum cleaner to o, then
switch o at the power outlet, and then unplug
the vacuum cleaner when not in use and prior to
cleaning the dust container or lters.
Never use the vacuum cleaner without a dust
container and motor protection lter in place.
Never use the vacuum cleaner to vacuum hot
ashes, broken glass, sharp objects or liquids.
Never use in the presence o explosive liquids or
vapours.
Never vacuum up infammable or poisonous
liquids such as petrol, copier toner or other volatile
substances. Never vacuum up acids, asbestos or
asbestos dust.
Do not leave the vacuum cleaner unattended
when in use. Young children should be supervisedto ensure that they do not play with the vacuum
cleaner.
Close supervision is required at all times when
operating the vacuum cleaner near children.
This vacuum cleaner is suitable or domestic use
only. Do not use this vacuum cleaner or anything
other than its intended use.
•
•
•
•
•
•
•
•
•
•
•
Do not use or store outdoors.
Fully extend the cord (to the yellow tape mark)
whenever the vacuum cleaner is in use. Please
ensure that the cord is not extended past the red
tape mark.This appliance is not intended or use by
persons (including children) with reduced
physical, sensory or mental capabilities or lack
o experience and knowledge unless they have
been given supervision or instruction concerning
use o the appliance by a person responsible or
their saety.
Do not leave the appliance unattended when in
use.
Children should be supervised to ensure that theydon’t play with the appliance.
Regularly inspect the supply cord, plug and
actual appliance or any damage. I damage is
ound in any way, immediately cease use o the
appliance and return the entire appliance to your
nearest authorised Kambrook service centre or
examination, replacement or repair.
The installation o a residual current device (saety
switch) is recommended to provide additional
saety protection when using electrical appliances.It is advisable that a saety switch with a rated
residual operating current not exceeding 30mA
be installed in the electrical circuit supplying the
appliance. See you electrician or proessional
advice.
•
•
•
•
•
•
•
KAMBROOK RECOMMENDS SAFETY FIRST
At Kambrook, we believe that sae perormance is the frst priority in any consumer product,so that you, our valued customer can confdently use and trust our products. We ask that anyelectrical appliance that you use be operated in a sensible ashion with due care and attentionplaced on the ollowing important operating instructions.
IMPORTANT SAFEGUARDS FOR YOUR KAMBROOK CAPTIVG3LIFT CYCLONIC BAGLESS VACUUM
KBV220-280_IB_FA.indd 2 11/6/09 4:04:23 PM
8/14/2019 Cyclonic Bagless Vacuum KBV220/280
http://slidepdf.com/reader/full/cyclonic-bagless-vacuum-kbv220280 3/12
Fully unwind the power cord beore use.
Do not let the power cord hang over the edge o
a bench or table, touch hot suraces or become
knotted.
The appliance is not intended or use by persons(including children) with reduced physical, sensory
or mental capabilities, or lack o experience
and knowledge, unless they have been given
supervision or instruction concerning use o
the appliance by a person responsible or their
saety.
Children should be supervised to ensure that they
do not play with the appliance.
It is recommended to regularly inspect the
appliance. To avoid a hazard do not use theappliance i power cord, power plug or appliance
becomes damaged in any way. Return the entire
appliance to the nearest authorised Kambrook
Service Centre or examination and/or repair.
•
•
•
•
•
Any maintenance other than cleaning should be
perormed at an authorised Kambrook Service
Centre.
This appliance is or household use only. Do not
use this appliance or anything other than itsintended use. Do not use in moving vehicles or
boats. Do not use outdoors. Misuse may cause
injury.
The installation o a residual current device (saety
switch is recommended to provide additional
saety protection when using electrical appliances.
It is advisable that a saety switch with a rated
residual operating current not exceeding 30mA
be installed in the electrical circuit supplying the
appliance. See your electrician or proessionaladvice.
•
•
•
IMPORTANT SAFEGUARDS FOR ALL ELECTRICAL APPLIANCES
KBV220-280_IB_FA.indd 3 11/6/09 4:04:23 PM
8/14/2019 Cyclonic Bagless Vacuum KBV220/280
http://slidepdf.com/reader/full/cyclonic-bagless-vacuum-kbv220280 4/12
KNOW YOUR KAMBROOK CAPTIVG3LIFT CYCLONIC BAGLESS VACUUM
1 Bagless convenience, or easy removal o dirtand dust with no need or replacement bags
2 Variable power control3 1500 watt motor or superior suction, ast and
eective cleaning
4 Dust level indicator
5 Quality multi-terrain loor tool ideal or carpetand hard loors
6 Hard loor tool or improved pick up on hardloors (KBV280 only)
7 Telescopic chrome steel wand is easily
extendable or retractable or varying heightrequirements
8 Cyclonic cone helps separate particles romthe air beore iltering begins
9 Two washable HEPA ilters included10 Auto cord rewind
11 Convenient carry handle
12 Cord length 5m
13 Small brush
14 Upholstery tool
15 Crevice tool
1
7
3
5
2
10 11
12
813
14
15
6
9
4
KBV220-280_IB_FA.indd 4 11/6/09 4:04:25 PM
8/14/2019 Cyclonic Bagless Vacuum KBV220/280
http://slidepdf.com/reader/full/cyclonic-bagless-vacuum-kbv220280 5/12
OPERATING INSTRUCTIONS
BEFORE FIRST USE
Remove any promotional material rom the vacuum
cleaner.
When unpacking the vacuum cleaner check to see
you have received all the required components,
such as the hose and other accessories beore
discarding the packaging.
TO OPERATE THE VACUUM CLEANER
Locate the crush proo hose and push the
connection point into the hose inlet connection on
the ront side o the vacuum, until a “click” sound
is heard.
Connect the wide end o the metal wand to thehose end, and push together rmly.
Fit the foor tool to the narrow end o the wand and
push together rmly.
Fully extend the power cord by pulling the power
plug out rom the rear o the vacuum, until the
yellow tape on the cord is showing.
NOTE: Ensure that you do not over extend the
power cord – do not extend past the red warning
tape on the cord.
Plug into a 230/240V power point and switch the
power on at the power point.
To commence vacuuming, push down on the on/o
button
on the top o the vacuum cleaner.
When vacuuming is complete, push down on the
‘on/o’ button to switch o. Turn the power o at
the outlet and then remove the power cord rom
the power outlet. When removing the plug rom the
power outlet, grasp the plug not the cord.
To retract the cord push down on the ‘cord rewind’
button
on top o the vacuum cleaner.
IMPORTANT: HOLD THE PLUG END AND GUIDE THE CORDINTO THE VACUUM DURING RETRACTION TO PREVENT IT FROM
STRIKING YOU OR THE VACUUM.
CAUTION: ALWAYS ENSURE THAT THE DUST CONTAINER
AND THE MOTOR PROTECTION FILTER ARE CORRECTLY FITTED.
NEVER OPERATE WITHOUT THE DUST CONTAINER OR FILTERS
IN PLACE.
VARIABLE POWER CONTROL
The power booster lever on the vacuum can beused or variable power control. Slide the lever
toward the MAX marking or vacuuming hard foor
and carpet suraces. Slide the lever toward the
MIN marking when using the crevice, upholstery
and brush tools.
KBV220-280_IB_FA.indd 5 11/6/09 4:04:25 PM
8/14/2019 Cyclonic Bagless Vacuum KBV220/280
http://slidepdf.com/reader/full/cyclonic-bagless-vacuum-kbv220280 6/12
CREVICE AND BRUSH TOOLACCESSORIES
The crevice tool is ideal or vacuuming hard to
reach places such as the edges along skirting
boards.
The brush and upholstery tools can be used to
vacuum delicate suraces and areas such as
shelves and venetian blinds.
Set the variable speed control between minimum
and medium power when using the tool
accessories.
Turn o the vacuum cleaner when changing any
attachments.
HARD FLOOR TOOL (KBV280 ONLY)
The hard foor tool is ideal or vacuuming hard
foors, with improved pick-up.
Simply t the hard foor tool to the narrow end o
the wand and push together rmly.
Turn o the vacuum cleaner when changing any
tools. Follow the ‘TO OPERATE THE VACUUM
CLEANER’ instructions to commence vacuuming.
CARE AND MAINTENANCE
Check all lters and replace them regularly. It is
recommended to clean the lters ater every use.
For normal household vacuuming the lters should
be replaced at least twice a year.
I you encounter reduced vacuum cleaner
perormance, check:
Dust capacity in dust container
All lters, including dust, motor and exhaust. Any
clogging in the lters will reduce the eciency o
your vacuum cleanerTo clean the outside o the unit, wipe the exterior
with a sot, damp cloth. Never use an abrasive
cleaner.
EMPTYING THE DUST CONTAINER
Always switch the vacuum o, then switch o
at the power outlet and unplug prior to replacing
lters or emptying the dust container.
For optimum use, the dust container should beemptied ater every use. When the dust container
•
•
KBV220-280_IB_FA.indd 6 11/6/09 4:04:26 PM
8/14/2019 Cyclonic Bagless Vacuum KBV220/280
http://slidepdf.com/reader/full/cyclonic-bagless-vacuum-kbv220280 7/12
reaches the capacity mark ‘MAX’, it is essential to
thoroughly clean both the dust container and lters.
To remove the dust container, ensure the vacuum
is down on its wheels; remove the dust container
by pressing down on the button on top o the dustcontainer. Once released careully lit the container
upwards.
To empty the dust container simply place it over
the rubbish bin, ensuring the opening o the bin is
larger than the dust container. Press the “PUSH”
button located beneath the hose inlet connection
on the ront o the dust container. The bottom o the
container will release and the dust and compiled
dirt will be dispensed.NOTE: Dependant upon the amount and type o dirt
collected in the dust container, it may be necessary
to agitate the dirt inside the dust container or
easier dispensing.
IMPORTANT: DO NOT USE THE UNIT WITHOUT A DUST
CONTAINER IN PLACE.
CLEANING AND REPLACING FILTERS
To assist you with the regular care o your vacuum,
a second HEPA lter is supplied or convenient use,
ideal or when a dirty lter is being cleaned.
Dirty and clogged lters may result in reducedsuction perormance. It is recommended that lters
are cleaned ater every use and replaced regularly
to ensure maximum eciency rom your vacuum.
I lters are let uncleaned, it may result in a
reduction o suction power. Should this occur, the
ollowing procedure should be ollowed every
couple o months.
PROCEDURE TO REPLACE FILTERS
Always switch the vacuum o, then switch o at
the power outlet and unplug prior to cleaning orreplacing the lters. Beore replacing the lters
ensure all dirt and dust is rst emptied rom the
dust container. Reer to the ‘EMPTYING THE DUST
CONTAINER’ section.
Remove the dust container rom the vacuum
by pressing down on the button on top o the
dust container. Once released, careully lit the
container upwards.
To remove the HEPA lter rom the back (fat
side) o the dust container, press the tab and
pull out the HEPA lter, ollowed by the oam
lter.
1.
2.
KBV220-280_IB_FA.indd 7 11/6/09 4:04:26 PM
8/14/2019 Cyclonic Bagless Vacuum KBV220/280
http://slidepdf.com/reader/full/cyclonic-bagless-vacuum-kbv220280 8/12
Shake and tap the HEPA lter until all the ne
dust particles are removed. Ater approximately
6 months the HEPA lter should be replaced.
This period is dependant upon the requency
o use and type o dirt being subjected to thevacuum.
The HEPA lter can also be hand washed in
warm water.
NOTE: Do not use any detergents or boiling water
to wash the lter, do not wash the lter in a
dishwasher or washing machine.
It is advised to let the lter dry completely or at
least a minimum o 24 hours beore use.
NOTE: Do not dry in a tumble dryer, microwave,
oven or near a naked fame. The lter and lter case must be completely dry beore replacing into the
vacuum. Failure to allow the lter to completely dry
may result in damage to the vacuum motor.
NOTE: A second hepa lter is supplied or
convenience, ideal or when a used lter is being
cleaned.
To place the lter back in the dust container,
ensure that the lter is completely dry beore
3.
4.
use. Close the bottom o the container.
Simply place the oam lter into the back o the
HEPA lter and then click the lter assembly
into the back o the dust container.
To remove and clean the CaptivG3 cone rom
inside the dust container, rstly ensure the
dust container has been emptied. Follow
the ‘EMPTYING THE DUST CONTAINER’
instructions.
Press the ‘PUSH’ button located beneath the
hose inlet connection on the ront o the dust
container. The bottom o the container will
release. Grip the two pockets at the base o the
cone with two ngers, twist anti-clockwise to‘OPEN’ and pull to remove the cone.
Shake and tap the cone until all the ne dust
particles are removed. The cone can also be
hand washed. Allow the cone to completely air
dry beore re-assembling.
To replace the cone into the dust container, grip
the two pockets at the base o the cone with
two ngers, slide the cone into the allocated
bracket inside the dust container and twist
clockwise to ‘CLOSE’ until resistance is elt.
5.
6.
KBV220-280_IB_FA.indd 8 11/6/09 4:04:27 PM
8/14/2019 Cyclonic Bagless Vacuum KBV220/280
http://slidepdf.com/reader/full/cyclonic-bagless-vacuum-kbv220280 9/12
Place the dust container back in the vacuum
cleaner or next use.
ExHAUST FILTER
The exhaust lter should be cleaned every sixmonths. Simply unclip the grill on the top o the
vacuum cleaner towards the rear, shake and tap
the lter to remove any dust accumulated. Then
relocate the lter and reattach the grill.
CARE AND MAINTENANCE
Always switch the vacuum o, then switch o at
the power outlet and unplug the appliance prior to
cleaning or replacing either lter.
To clean the outside o the unit, wipe the exterior
with a sot, damp cloth. Never use an abrasivecleaner.
IMPORTANT: CHECK AND REPLACE bOTH THE MOTOR
PROTECTION AND HEPA FILTERS APPROxIMATELY TWICE A
YEAR OR WHEN VIS IbLY CLOGGED.
7.
KBV220-280_IB_FA.indd 9 11/6/09 4:04:27 PM
8/14/2019 Cyclonic Bagless Vacuum KBV220/280
http://slidepdf.com/reader/full/cyclonic-bagless-vacuum-kbv220280 10/12
10
TROUBLE SHOOTING GUIDE
PROBLEM POSSIBLE CAUSES WHAT TO DO
Vacuum cleaner is not working The unit may not be pluggedinto power outlet
• Ensure the power plug issecurely plugged
•
Vacuum cleaner is not picking
up dirt
Dust container is ull
Filter is clogged
Dust container is not tted
correctly
•
•
•
Empty and clean the dust
container
Reer to ‘Cleaning and
Replacing Filters’, page 7
Check dust container
replacement
•
•
•
Dust escaping rom vacuum
Dust container is not ttedcorrectly
Hose is not tted correctly
Dust container is ull
•
•
•
Check dust container
installation
Check hose installation
Empty and clean the dust
container
•
•
•
SPARE PARTS
To order spare parts or your Kambrook CaptivG3Lit Cyclonic Bagless Vacuumplease contact Customer Service on:
1300 139 789 (Australia)
and 0800 253 007 (New Zealand)
KBV220-280_IB_FA.indd 10 11/6/09 4:04:27 PM
8/14/2019 Cyclonic Bagless Vacuum KBV220/280
http://slidepdf.com/reader/full/cyclonic-bagless-vacuum-kbv220280 11/12
11
NOTES
KBV220-280_IB_FA.indd 11 11/6/09 4:04:27 PM
8/14/2019 Cyclonic Bagless Vacuum KBV220/280
http://slidepdf.com/reader/full/cyclonic-bagless-vacuum-kbv220280 12/12
12
Kambrook warrants the purchaser against defects in workmanship and material for a period of 12 months
from the date of purchase (3 months commercial use).
Guarantee and purchase receipt for this product are to be retained as proof of purchase and must be
presented if making a claim under the Kambrook guarantee.
Kambrook reserves the right to replace or repair the appliance within the warranty period.
Warranty does not apply to any defect, deterioration, loss, injury or damage occasioned by, or as a result
of the misuse or abuse, negligent handling or if the product has not been used in accordance with the
instructions. The guarantee excludes breakages and consumable items such as kneading blades.
This warranty is void if there is evidence of the product being tampered with by unauthorised persons.
If the product includes one or a number of accessories only the defective accessory or product will be
replaced. In the event of Kambrook choosing to replace the appliance, the guarantee will expire at the
original date, i.e. 12 months from the original date of purchase.
In Australia, this KAMBROOK Guarantee is additional to the conditions and guarantees which are mandatory
as implied by the Trade Practises Act 1974 and State and Territory legislation.
For service, spare parts or product information in Australia, please call KAMBROOK on the Customer
Service Line; 1300 139 798.
For service, spare parts or product information in New Zealand, please call KAMBROOK on the Customer
Service Line; 080 0 273 845 or 09 271 3980.
If claiming this guarantee the product must be returned freight prepaid.
KAMBROOK 12 MONTH REPLACEMENT WARRANTY
YOUR PURCHASE RECORD (Please complete)
DATE OF PURCHASE .......................................................
MODEL NUMBER .............................................................
SERIAL NUMBER .............................................................
PURCHASED FROM .........................................................
Attach a copy of the purchase receipt here.
(Please don’t return purchase record
until you are making a claim)
Due to continual improvement in design or other wise, the product you purchase may differ slight ly from the illustrat ion in this book. Issue 1/09
KAMBROOK 12 MONTH REPLACEMENT WARRANTY
Register your warranty at www.kambrook.com.au/service.asp
Kambrook - Australia
Building 2, Port Air Industrial Estate
1A Hale Street
Botany NSW 2019
Australia
Customer Service Line 1300 139 798
Customer Service Fax 1800 621 337
Kambrook - New ZealandPrivate Bag 94 411
Greenmount, Manukau
Auckland 2141New Zealand
Customer Service Line/Spare Parts 0800 273 845or 09 271 3980
Customer Service Fax 0800 288 513