GRUNER AGPF 1149, D-78560 Wehingen
Tel. (++49) 74 26 / 948 - 0Fax (++49) 74 26 / 948 - 200
http://www.gruner.deE-Mail: [email protected]
16/07 · FSOE · Copyright by Gruner AG · Technical changes are reserved
Actuator with spring return
5 Nm
20 Nm
For the application with
Fire dampersSmoke dampers
��� ACTUATOR FOR DAMPERS
F ire & Smoke Protect ion
G R U N E R – t h e f r i e n d l y a l t e r n a t i v e
���
General overview fire & smoke protection
Summary: Actuators for fire & smoke protection
Technical characteristics, Type 229, 5 Nm
Technical characteristics, Type 239, 20 Nm
Your way to Gruner
Content:
2
3
4 - 7
8 - 11
12
Page:
GRUNER AGPF 1149, D-78560 Wehingen
Tel. (++49) 74 26 / 948 - 0Fax (++49) 74 26 / 948 - 200
http://www.gruner.deE-Mail: [email protected]
20/06· FSOE · Copyright by Gruner AG · Technical changes are reserved
��� GENERAL OVERVIEW: FIRE & SMOKE PROTECTION
Applications
● = Standard
❍ = Optional
TypeSpring Return
Torque (Actuator)
Torque (Spring)
Angle of Rotation
ControlOn/Off
Power Supply24 VAC/DC
230 VAC
OptionsAuxiliary switch(es)
Thermal Tripping Device
(72°C)
Thermal Tripping Device
for Duct Mounting (72°C)
229●
5 Nm (ca. 1 m2)
4 Nm
100°
●
●
●
●
❍
239●
20 Nm (ca. 4 m2)
15 Nm
100°
●
●
●
●
❍
❍
Fire Protection
���
2
Motorised control of fire and smoke dampers in
HVAC systems.
All actuators correspond to the DIN-VDE standards
and CE guidelines.
GRUNER AGPF 1149, D-78560 Wehingen
Tel. (++49) 74 26 / 948 - 0Fax (++49) 74 26 / 948 - 200
http://www.gruner.deE-Mail: [email protected]
16/07 · FSOE · Copyright by Gruner AG · Technical changes are reserved
��� SUMMARY: ACTUATORS FOR FIRE & SMOKE PROTECTION
TypeTorque (Actuator)
Torque (Spring)
On/Off Control
Angle of Rotation
Power Supply24 VAC/DC
230 VAC
OptionsThernal Tripping Device
(72°C)
Thernal Tripping Device
for Duct Mounting (72°C)
Auxiliary switch(es)
Page
5 Nm
4 Nm
●
100°
●
●
4
5 Nm
4 Nm
●
100°
●
●
●
4
5 Nm
4 Nm
●
100°
●
●
6
229-
024-
05-S
2
229T
A-024
-05-
S2
229-
230-
05-S
2● = Standard
❍ = Optional
3
Actuators typ 239 dispose of the manual override option by crank. Actuators according to US standard available upon demand.
5 Nm
4 Nm
●
100°
●
●
●
6
229T
A-230
-05-
S2
239-
024-
20-S
2
20 Nm
15 Nm
●
100°
●
●
8
239T
-024
-20-
S2
20 Nm
15 Nm
●
100°
●
●
●
8
239T
A-024
-20-
S2
20 Nm
15 Nm
●
100°
●
●
●
8
239-
230-
20-S
2
20 Nm
15 Nm
●
100°
●
●
10
239T
-230
-20-
S2
20 Nm
15 Nm
●
100°
●
●
●
10
239T
A-230
-20-
S2
20 Nm
15 Nm
●
100°
●
●
●
10
Important NoteThe modification and mounting of the actuator to the fire damper is made by the manufacturer of the damper. For this reason the spring-return actuator
is only supplied directly to manufacturers of fire dampers. The manufacturer then bears overall responsibility for proper functioning of the damper.
���
GRUNER AGPF 1149, D-78560 Wehingen
Tel. (++49) 74 26 / 948 - 0Fax (++49) 74 26 / 948 - 200
http://www.gruner.deE-Mail: [email protected]
16/07 · FSOE · Copyright by Gruner AG · Technical changes are reserved
��� 229-024-05-S2, 229TA-024-05-S2
229-024-05-S2
1 2 3
S1
4 5 6
S2
BUBN
229TA-024-05-S2
Applications
1 2 3
S1
4 5 6
S2
BUBN
TF1 TF2
TA
Connection scheme Connection scheme
���
To regulate fire and smoke dampers in HVAC
systems:
• Form-locking steel drive
• Torque 5 Nm / 4 Nm
• Angle of rotation 100°
• Hold safe position in case of high temperature
• no manual operation and position fixing
• reliable safe postion
• Electromagnetic compatibility controlled
4
Technical Characteristics
Control
Connecting voltage
Power consumption
Transformer sizing
Angle of rotation
Direction of rotation
Running time (90°)
Torque
Auxiliary switches
Switching power Auxiliary switches
Connection
Safety class
Protection
Dimensions
Ambient temperature
Maintenance
CE
Weight
On/Off
24 VAC (50/60 Hz) / DC ± 20%
Motion: 5.0 W / Power safe mode: 3.0 W
6.5 VA
100° (-5°...+95°)
can be selected by mounting back to front
Actuator: < 40...75 s / Spring: < 20 s
Actuator: 5 Nm / Spring: 4 Nm
2, position fixed to 5° and 80°
250 VAC / 5.0 (2.5) A, change-over switch
Cable 900 mm / 0.75 mm2
III
IP54 (Cable downwards)
158 x 66 x 61 mm
-30°C...+50°C
maintenance-free
73/23/EWG, 89/336/EWG
1,100 g
GRUNER AGPF 1149, D-78560 Wehingen
Tel. (++49) 74 26 / 948 - 0Fax (++49) 74 26 / 948 - 200
http://www.gruner.deE-Mail: [email protected]
16/07 · FSOE · Copyright by Gruner AG · Technical changes are reserved
��� 229-024-05-S2, 229TA-024-05-S2
Technical drawing
BU, BN
TA
1,2,3,4,5,6
66.00±1.00
93.00±0.50
157.00±1.00
R65.00
R11.00
48.5082.50
11.00
6.00
52.00
R2.00
12.20
12.20
,8,2
0
,4,6
1
61.00±1.00
12.00
66.00
2.002.00
13.0013.00
229-024-05-S2
���
5
Fixing of the shaft
Concentric form locking shaft: ❑ 8...12 mm
Thermal tripping devices (Fig. 1 + 2)
Auxiliary switches
The actuator has two position fixed auxiliary switches for indicating the damper postion. The position of
the damper can be read on the scale on front of the actuator.
Self test
Duct temperature
Ambient temperature
If 72°C are reached the actuator turns the damper back to its safe position.
Version
TA
Yes
Yes
Yes
66.0
0±1.
002.
0027
.60
Ø9.00
40.0
050
.00
50.00
2.8...Ø3
20.0
020
.00
107.
00±
2.00
2.8...Ø3
9.5...Ø10
2 Thermal tripping device TA
1
GRUNER AGPF 1149, D-78560 Wehingen
Tel. (++49) 74 26 / 948 - 0Fax (++49) 74 26 / 948 - 200
http://www.gruner.deE-Mail: [email protected]
16/07 · FSOE · Copyright by Gruner AG · Technical changes are reserved
��� 229-230-05-S2, 229TA-230-05-S2
229-230-05-S2
1 2 3
S1
4 5 6
S2
BUBN
NL
229TA-230-05-S2
Applications
1 2 3
S1
4 5 6
S2
BUBN
TF1 TF2
TA
NL
Connection scheme Connection scheme
���
To regulate fire and smoke dampers in HVAC
systems:
• Form-locking steel drive
• Torque 5 Nm / 4 Nm
• Angle of rotation 100°
• Hold safe position in case of high temperature
• no manual operation and position fixing
• reliable safe postion
• Electromagnetic compatibility controlled
6
Technical Characteristics
Control
Connecting voltage
Power consumption
Transformer sizing
Angle of rotation
Direction of rotation
Running time (90°)
Torque
Auxiliary switches
Switching power Auxiliary switches
Connection
Safety class
Protection
Dimensions
Ambient temperature
Maintenance
CE
Weight
On/Off
230 VAC (50/60 Hz) ± 15%
Motion: 5.0 W / Power safe mode: 2.5 W
5.5 VA
100° (-5°...+95°)
can be selected by mounting back to front
Actuator: < 40...75 s / Spring: < 20 s
Actuator: 5 Nm / Spring: 4 Nm
2, position fixed to 5° and 80°
250 VAC / 5.0 (2.5) A, change-over switch
Cable 900 mm / 0.75 mm2
II
IP54 (Cable downwards)
158 x 66 x 61 mm
-30°C...+50°C
maintenance-free
73/23/EWG, 89/336/EWG
1,100 g
GRUNER AGPF 1149, D-78560 Wehingen
Tel. (++49) 74 26 / 948 - 0Fax (++49) 74 26 / 948 - 200
http://www.gruner.deE-Mail: [email protected]
16/07 · FSOE · Copyright by Gruner AG · Technical changes are reserved
��� 229-230-05-S2, 229TA-230-05-S2
Technical drawing
BU, BN
TA
1,2,3,4,5,6
66.00±1.00
93.00±0.50
157.00±1.00
R65.00
R11.00
48.5082.50
11.00
6.00
52.00
R2.00
12.20
12.20
,8,2
0
,4,6
1
61.00±1.00
12.00
66.00
2.002.00
13.0013.00
229-230-05-S2
���
7
Fixing of the shaft
Concentric form locking shaft: ❑ 8...12 mm
Thermal tripping devices (Fig. 1 + 2)
Auxiliary switches
The actuator has two position fixed auxiliary switches for indicating the damper postion. The position of
the damper can be read on the scale on front of the actuator.
Self test
Duct temperature
Ambient temperature
If 72°C are reached the actuator turns the damper back to its safe position.
Version
TA
Yes
Yes
Yes
66.0
0±1.
002.
0027
.60
Ø9.00
40.0
050
.00
50.00
2.8...Ø3
20.0
020
.00
107.
00±
2.00
2.8...Ø3
9.5...Ø10
2 Thermal tripping device TA
1
GRUNER AGPF 1149, D-78560 Wehingen
Tel. (++49) 74 26 / 948 - 0Fax (++49) 74 26 / 948 - 200
http://www.gruner.deE-Mail: [email protected]
16/07 · FSOE · Copyright by Gruner AG · Technical changes are reserved
��� 239-024-20-S2, 239T-024-20-S2, 239TA-024-20-S2
239-024-20-S2
1 2 3
S1
4 5 6
S2
BUBN
239T-024-20-S2
Applications
1 2 3
S1
4 5 6
S2
BUBN
TF1
T
239TA-024-20-S2
1 2 3
S1
4 5 6
S2
BUBN
TF1 TF2
TA
Connection scheme Connection scheme Connection scheme
���
To regulate fire and smoke dampers in HVAC
systems:
• Form-locking steel drive
• Torque 20 Nm / 15 Nm
• Angle of rotation 100°
• Hold safe position in case of high temperature
• manual operation and position fixing
• reliable safe postion
• Electromagnetic compatibility controlled
8
Technical Characteristics
Control
Connecting voltage
Power consumption
Transformer sizing
Angle of rotation
Direction of rotation
Running time (90°)
Torque
Auxiliary switches
Switching power Auxiliary switches
Connection
Safety class
Protection
Dimensions
Ambient temperature
Maintenance
CE
Weight
On/Off
24 VAC (50/60 Hz) / DC ± 20%
Motion: 6.5 W / Power safe mode: 4,0 W
10 VA
100° (-5°...+95°)
can be selected by mounting back to front
Actuator: 150 s / Spring: < 20 s
Actuator: 20 Nm / Spring: 15 Nm
2, position fixed to 5° and 80°
250 VAC / 5.0 (2.5) A, change-over switch
Cable 900 mm / 0.75 mm2
III
IP54 (Cable downwards)
250 x 98 x 58 mm
-30°C...+50°C
maintenance-free
73/23/EWG, 89/336/EWG
2,500 g
GRUNER AGPF 1149, D-78560 Wehingen
Tel. (++49) 74 26 / 948 - 0Fax (++49) 74 26 / 948 - 200
http://www.gruner.deE-Mail: [email protected]
16/07 · FSOE · Copyright by Gruner AG · Technical changes are reserved
��� 239-024-20-S2, 239T-024-20-S2, 239TA-024-20-S2
Technical drawing
149
250
10
365
67
9880
Ø6(6x)
R12
582
2
43
15
24
5°
80°
Motor
S1, S2
1, 2, 3, 4, 5, 6
bl, br
27
239-024-20-S2
���
9
Fixing of the shaft
Concentric form locking shaft: ❑ 8...12 mm
Auxiliary switches
The actuator has two position fixed auxiliary switches for indicating the damper postion. The position of
the damper can be read on the scale on front of the actuator.
66.0
0±1.
002.
0027
.60
Ø9.00
40.0
050
.00
50.00
2.8...Ø3
20.0
020
.00
107.
00±
2.00
2.8...Ø3
9.5...Ø10
2 Thermal tripping device TA
Thermal tripping devices (Fig. 1 + 2)
Self test
Duct temperature
Ambient temperature
If 72°C are reached the actuator turns the damper back to its safe position.
Version
TA
Yes
Yes
Yes
Version
T
No
No
Yes
1
GRUNER AGPF 1149, D-78560 Wehingen
Tel. (++49) 74 26 / 948 - 0Fax (++49) 74 26 / 948 - 200
http://www.gruner.deE-Mail: [email protected]
16/07 · FSOE · Copyright by Gruner AG · Technical changes are reserved
��� 239-230-20-S2, 239T-230-20-S2, 239TA-230-20-S2
239-230-20-S2
1 2 3
S1
4 5 6
S2
BUBN
NL
239T-230-20-S2
Applications
1 2 3
S1
4 5 6
S2
BUBN
TF1
T
NL
239TA-230-20-S2
1 2 3
S1
4 5 6
S2
BUBN
TF1 TF2
TA
NL
Connection scheme Connection scheme Connection scheme
���
To regulate fire and smoke dampers in HVAC
systems:
• Form-locking steel drive
• Torque 20 Nm / 15 Nm
• Angle of rotation 100°
• Hold safe position in case of high temperature
• manual operation and position fixing
• reliable safe postion
• Electromagnetic compatibility controlled
10
Technical Characteristics
Control
Connecting voltage
Power consumption
Transformer sizing
Angle of rotation
Direction of rotation
Running time (90°)
Torque
Auxiliary switches
Switching power Auxiliary switches
Connection
Safety class
Protection
Dimensions
Ambient temperature
Maintenance
CE
Weight
On/Off
230 VAC (50/60 Hz) ± 15%
Motion: 9.0 W / Power safe mode: 7,0 W
10.0 VA
100° (-5°...+95°)
can be selected by mounting back to front
Actuator: 150 s / Spring: < 20 s
Actuator: 20 Nm / Spring: 15 Nm
2, position fixed to 5° and 80°
250 VAC / 5.0 (2.5) A, change-over switch
Cable 900 mm / 0.75 mm2
II
IP54 (Cable downwards)
250 x 98 x 58 mm
-30°C...+50°C
maintenance-free
73/23/EWG, 89/336/EWG
2,500 g
GRUNER AGPF 1149, D-78560 Wehingen
Tel. (++49) 74 26 / 948 - 0Fax (++49) 74 26 / 948 - 200
http://www.gruner.deE-Mail: [email protected]
16/07 · FSOE · Copyright by Gruner AG · Technical changes are reserved
��� 239-230-20-S2, 239T-230-20-S2, 239TA-230-20-S2
Technical drawing
149
250
10
365
67
9880
Ø6(6x)
R12
582
2
43
15
24
5°
80°
Motor
S1, S2
1, 2, 3, 4, 5, 6
bl, br
27
239-230-20-S2
���
11
Fixing of the shaft
Concentric form locking shaft: ❑ 8...12 mm
Thermal tripping devices (Fig. 1 + 2)
Auxiliary switches
The actuator has two position fixed auxiliary switches for indicating the damper postion. The position of
the damper can be read on the scale on front of the actuator.
Self test
Duct temperature
Ambient temperature
If 72°C are reached the actuator turns the damper back to its safe position.
Version
TA
Yes
Yes
Yes
66.0
0±1.
002.
0027
.60
Ø9.00
40.0
050
.00
50.00
2.8...Ø3
20.0
020
.00
107.
00±
2.00
2.8...Ø3
9.5...Ø10
2 Thermal tripping device TA
Version
T
No
No
Yes
1
GRUNER AGPF 1149, D-78560 Wehingen
Tel. (++49) 74 26 / 948 - 0Fax (++49) 74 26 / 948 - 200
http://www.gruner.deE-Mail: [email protected]
16/07 · FSOE · Copyright by Gruner AG · Technical changes are reserved
��� YOUR WAY TO GRUNER
���
���
MünchenStuttgart
Zürich
Singen
Freudenstadt
Wehingen
Offenburg
Strasbourg
Schramberg
Karlsruhe
A81
N3N1
Basel
34
A8
B14
B27
Donaueschingen
B27
Balingen
Tutt l ingen
Spaichingen
B33A5
Rottwei l
Aldingen
Gosheim
Schömberg
DenkingenFrit t l ingen
Freiburg
B31