Download - Db-60 Manual 120811 Print
-
8/18/2019 Db-60 Manual 120811 Print
1/60
DB-60Standard & 359˚ Oscillation Un
OPERATING & PARTS MANUAL
Rev. 07/
DUSTBOSS®
KNOWS...
-
8/18/2019 Db-60 Manual 120811 Print
2/60
i
IMPORTANT
DUST CONTROL TECHNOLOGY, INC., HEREBY DISCLAIMS ANY LIABILITY FOR: DAMAGE DUE TO CONTAMINATION
OF THE MATERIAL; USER’S FAILURE TO INSPECT, MAINTAIN AND TAKE REASONABLE CARE OF THE EQUIPMENT;
INJURIES OR DAMAGE RESULTING FROM USE OR APPLICATION OF THIS PRODUCT CONTRARY TO INSTRUCTIONS
AND SPECIFICATIONS CONTAINED HEREIN. DUST CONTROL TECHNOLOGY’S® LIABILITY SHALL BE LIMITED TO
REPAIR OR REPLACEMENT OF EQUIPMENT SHOWN TO BE DEFECTIVE.
Observe all safety rules given herein along with owner and Government standards and regulations. Know and understand
lockout/tagout procedures as defined by American National Standards Institute (ANSI) z244.1-1982, American National
Standard for Personnel Protection - Lockout/Tagout of Energy Sources - Minimum Safety Requirements and Occupational
Safety and Health Administration (OSHA) Federal Register, Part IV, 29 CFR Part 1910, Control of Hazardous Energy
Source (Lockout/Tagout); Final Rule.
THE FOLLOWING SYMBOLS MAY BE USED IN THIS MANUAL:
DANGER: Immediate hazards that will result in severe personal injury or death.
WARNING: Hazards or unsafe practices that could result in personal injury.
CAUTION: Hazards or unsafe practices that could result in product or property damages.
IMPORTANT: Instructions that must be followed to ensure proper installation/operation of equipment.
NOTE: General statements to assist the reader.
THE FOLLOWING DOCUMENTS ARE REFERENCED IN THIS MANUAL:
> American National Standards Institute (ANSI) z244.1-1982, American National Standard for Personnel Protection - Lockout/Tagout of Energy
Sources - Minimum Safety Requirements, American National Standards Institute, Inc., 1430 Broadway, New York, NY 10018.
> Federal Register, Volume 54, Number 169, Part IV, 29 CFR Part 1910, Control of Hazardous Energy Source (Lockout/Tagout);
Final Rule, Department of Labor, Occupational Safety and Health Administration (OSHA), 32nd Floor, Room 3244,
230 South Dearborn Street, Chicago, IL 60604.
> The National Electrical Code (NEC) Handbook, National Fire Protection Association, 1 Batterymarch Park, P.O. Box 9101,
Quincy MA 02269-9101.
> ICS 1-1988, General Standards for Industrial Control and Systems, and 250-1985, Enclosures for Electrical Equipment
(1000 Volts Maximum), National Electrical Manufacturers Association (NEMA), 2101 L Street N.W., Washington, D.C. 20037.
-
8/18/2019 Db-60 Manual 120811 Print
3/60
-
8/18/2019 Db-60 Manual 120811 Print
4/60
ii
TABLE OF CONTENTS
EG A PNOITCES
IMPORTANT ....................................................................................................................................................................................................i
..................................................................................................................................................................15
INTRODUCTION
> General ...........................................................................................................................................................................................................1
> Description .....................................................................................................................................................................................................1
> DB-60 Technical Specifications ..........................................................................................................................................................2–3
TRAINING & SAFETY
> Safety ...............................................................................................................................................................................................................4
> Materials Required.......................................................................................................................................................................................4
> Training ...........................................................................................................................................................................................................4> Precautions ..............................................................................................................................................................................................4–5
BEFORE INSTALLATION
> Before Using Your DustBoss® .................................................................................................................................................................6
OPERATING THE UNIT
> Safety ...............................................................................................................................................................................................................7
> Control Panel .................................................................................................................................................................................................7
> Unit Startup ...................................................................................................................................................................................................7
> Unit Shutdown .............................................................................................................................................................................................8
> Aiming the DustBoss® ...............................................................................................................................................................................8
HANDLING YOUR UNIT
> Transport & Positioning .............................................................................................................................................................................9
> DB-60 Machine Pivoting & Head Adjustment.............................................................................................................................10–11
STORAGE & MAINTENANCE
> Machine Storage & Placement Options ............................................................................................................................................12
> Winterizing Rules ......................................................................................................................................................................................12
> Daily Checklist ............................................................................................................................................................................................13
> Quarterly Maintenance Checklist ..........................................................................................................................................................13
REMINDERS
> Do’s, Don’ts & Remembers....................................................................................................................................................................14
ADDITIONAL RESOURCES
> Appendix of Figures ..................................................................................................................................................................................16
> Optional Booster Pump Information ............................................................................................................................................17–22
> Electrical Schematics ........................................................................................................................................................................23–24
> Parts List ...............................................................................................................................................................................................25–51
WARRANTY ..................................................................................................................................................................................................52
-
8/18/2019 Db-60 Manual 120811 Print
5/60
-
8/18/2019 Db-60 Manual 120811 Print
6/60
1
INTRODUCTION
Your DustBoss
®
Dust Controller has been designed for maximum throw while breaking
water into fine droplets to allow maximum dust control.
The DustBoss units were designed for hostile industrial environments. Simplicity of
design, ease of operation and maintenance are their key features. As you become more
familiar with your machine and its great versatility, you will appreciate the difference your
DustBoss can make to create a cleaner, safer environment.
The DB-60® uses this technology to cover 21,000 sq. ft. (1,950 sq. meters) with a fine mist of water,
or up to 125,000 sq.ft. (11,613 sq. meters) with optional 359˚ oscillation. Considerable effort has gone
GENERAL
into the research; testing and actual use have provided insight into the design and improvements
to the DustBoss units.
Dust Control Technology
®
is dedicated to providing our customers with superior qualityproducts for optimum trouble-free operation.
It is important that you have a full understanding of the contents of this manual. It contains
information which will help you operate your DustBoss in a safe manner and obtain
optimum performance from the system.
The DustBoss units utilize a ducted fan with an efficient water spray manifold and
nozzle system.
The most effective dust control is attained with a fine mist of water droplets, ranging from
50–200 microns in size, and proper location of the unit to use the wind to your advantage.
The spray manifold consists of a main water manifold with 30 nozzles. A simple
quick-disconnect system allows the feed hose to be easily connected.
A 3-wheel carriage system is utilized for both units. The DB-60 is safely powered with
a stainless steel control panel and 150 foot (45.72 meter) cord.
Intensive effort and research have gone into creating a safe and efficient dust controller.
If you have any questions on the operation of the equipment after reviewing this manual,
please contact your local representative or call Dust Control Technology directly at
800-707-2204 or 309-645-3691. In case of emergency, please call anytime, 24/7.
DESCRIPTION
DB-60 (left)
DB-30 (right)
-
8/18/2019 Db-60 Manual 120811 Print
7/60
2
TECHNICALSPECIFICATIONS
SPECIFICATIONS
General Specifications
> 30,000 CFM (849.50 CMM) generated by 25 HP fan.
> 21,000 square feet (1,950 square meters) coverage. Up to 125,000 square feet
(11,613 square meters) coverage available with optional 359˚ oscillation.
> Oscillator gives 0–40˚ of movement on standard unit. Unit can also be equipped with optional
increased oscillation, up to 359˚,
> Adjustable angle
of
throw
0–50˚
of height
adjustment.
Electrical Specifications
> U.S.: 3 Phase / 25 HP fan / 480 Volt / 60 Hertz. Full load current is 46 amps.
60 Kw gen set is recommended. Motor is designed with a 1.15 service factor
capable of operating at +/- 10% of design voltage.
> Other motor options available, including all international electrical motors:
• 3 Phase / 25 HP fan / 380 Volt / 50 Hz (Europe, Middle East, N. Japan, Latin America)
• 3 Phase / 25 HP fan / 400 Volt / 50 Hz (Europe, Japan, New Zealand, Australia)
• 3 Phase / 25 HP fan / 415 Volt / 50 Hz (Europe, New Zealand, Australia)
• 3 Phase / 25 HP fan / 575 Volt / 60 Hz (Canada)
• 3 Phase / 25 HP fan / 380 Volt / 60 Hz Korea)
• 3 Phase / 25 HP fan / 440 Volt / 60 Hz (Mexico)
> 380, 400, 415 volt / 50 Hz motors are designed with a 1.00 service factor
capable of operating at +/- 10% of design voltage.
> 10 HP (7.5 Kw) high-pressure booster pump with no lift.
> 1/8 HP (0.10 Kw) oscillator.
>
150 foot (45.72 meters) 6/4 electrical cord. Other options available.> No male plug, “bare wired” is standard, any plug is extra cost.
> Cabinet with control panel.
Water Specifications
> 10 PSI (0.689 BAR) constant pressure needs to be delivered to booster pump.
Maximum inlet water pressure should not exceed 100 PSI (6.89 BAR).
> Maximum PSI delivered by booster pump is 200 PSI (13.79
BAR).
> Filter is included and should be used at all times. Contact us for recommendations
when using nonpotable water. (Filter system in-line 30
mesh
595
micron).
> 1-1/2" (38.1 mm) cam-and-groove quick disconnect
female
coupling
for
fire hose provided on machine.
> 30 brass nozzles (also available in stainless and nylon).
> Droplet size 50–200 microns.
> Throw 200 feet (60 meters).
-
8/18/2019 Db-60 Manual 120811 Print
8/60
3
Noise Levels
Dimensions
Maintenance
> If using potable water, nozzles need to be inspected once a year.
> Fan motor and high pressure pump should be greased every 10,000 hours.
> Oscillator bearing should be greased on a regular maintenance schedule,
or as needed.
TECHNICALSPECIFICATIONS
(continued)
Chemical Additives
> Can be used with surfactant to improve binding of dust particles or with tackifying
agents to seal the ground to prevent dust from becoming airborne.
> Odor control chemicals can be used to help eliminate odor.
> Available on frame with skid mount. Unit comes standard on wheeled carriage.
> Dosing pump can be added to unit for chemical applications.
Optional
> Unit is available with optional increased oscillation, up to 359˚. Standard oscillation
provides 0–40˚ of movement.
ON STANDARD WHEELED CARRIAGE
6.75 feet (81 inches; or 2.06 meters) wide.
ON OPTIONAL FRAME WITH SKID MOUNT
6.33 feet (76 inches; or 1.93 meters) wide.>
> 9.75 feet (117 inches; or 2.97 meters) long.
> 7.17 feet (86 inches; or 2.19 meters) tall.
> 1800 lbs. (816.50 kilograms).
>
> 5.88 feet (70.5 inches; or 1.79 meters) long.
> 6.92 feet (83 inches; or 2.11 meters) tall.
> 1800 lbs. (816.50 kilograms).
-
8/18/2019 Db-60 Manual 120811 Print
9/60
4
TRAINING & SAFETY
All safety rules defined in the above documents, and all owner/employer safety rules,
must be strictly followed when installing and servicing this equipment.
Materials other than standard hand tools that are required to complete tasks are listed
where applicable. The DustBoss should be operated only by personnel who have knowledge
of the equipment and safety and operating procedures. This will prevent mishaps or injury
and will make dust control more efficient.
Operators should have a thorough understanding of the SAFETY procedures as well as
how to operate and handle problems that might occur.
They must know where the manual is located, how to use it for reference, and how touse the checklist prior to starting the DustBoss.
Your company is advised to develop custom training programs for your situations, and all
personnel associated with operating this equipment should receive instruction.
FOLLOW electrical guidelines at all times to avoid injury or death.
BE CERTAIN the “feed” power service and all power switches on the machine are OFF
before connecting or disconnecting the electrical plug. ELECTRICAL SHOCK CAN BE FATAL.
BE CERTAIN that the connection to the generator is made by a certified electrician and the
generator in grounded with a grounding rod. ELECTRICAL SHOCK CAN BE FATAL.
DO NOT open or work inside an electrical panel with the power source ON or CONNECTED.ELECTRICAL SHOCK CAN BE FATAL.
LOOSE CLOTHING SHOULD NOT BE WORN when operating the DustBoss to prevent
entangling in rotating equipment.
ALWAYS STAND OUT OF THE AIRSTREAM when starting, making adjustments, or while the
machine is running. This procedure is to prevent injury from possible flying foreign material.
STAND BEHIND water feeding valve/hydrant to open or close the water valve so that in
case of hose or connector failure, injury may be prevented.
ALWAYS open or close water valves VERY SLOWLY to gradually equalize the line and system
pressure to prevent hose, connector or pressurized system failure. Rapid opening and
closing of water valves releases a tremendous amount of energy and could cause a failurein any part of the total pressurized system or serious personal injury.
NEVER straddle a hose as serious injury could result.
DO NOT attempt to remove ice from fan or screen and DO NOT perform mechanical or
electrical service while the machine is in operation. NEVER run the machine without the
screen and guard in place.
DO NOT shut the water valve off while the booster pump is running.
TRAINING
PRECAUTIONS
SAFETY
MATERIALSREQUIRED
-
8/18/2019 Db-60 Manual 120811 Print
10/60
5
INAPPROPRIATE
USES
Fan Housing
DO NOT run over the fire hose that supplies water to the DustBoss. This can cause the
high pressure pump to trip out and shut the unit off. Protect the water supply with boards
on both sides of the hose.
NEVER move the DustBoss until the power service is OFF, and the power cord and hoses
are DISCONNECTED.
DO NOT leave hoses and cords laying around. They can possibly cause injury if run over.
DO NOT use clogged or damaged nozzles. Clogged nozzles cause erratic spray patterns
that decrease efficiency.
MONITOR THE MACHINE frequently to determine if problems are developing that could
cause personal injury, machine damage or unnecessary downtime.
FOR WINTER OPERATION, be cautious of ice, snow, wet, slippery conditions and other
hazards in the area.
NEVER place limbs or other body parts into the fan housing.
RULES FOR SAFE OPERATION
The manual should be read by all personnel associated
with misting.
> All personnel should be familiar with the machine and
be versed in their area’s safety procedures.
> Moving the machine while operating is not recommended.
> Operators should exercise caution while operating the
DustBoss. Care should be taken with clothing (i.e., scarves,
hats, hair, loose jackets, etc.) when working with any
rotating equipment.
> Always open and close hydrants/valves slowly. Rapid opening
and closing could damage the equipment, pipes and pumps,
or cause serious injury.
> Determine if appropriate signing or fencing of machine is
needed and in place.
The DustBoss is only intended for use as a dust and odor control device. Any other use
of the equipment is considered inappropriate.
PRECAUTIONS
(continued)
IF YOU EXPERIENCE UNUSUAL NOISE OR VIBRATION, shut the machine down immediatelyand contact your local representative or Dust Control Technology directly at 800-707-2204
or 309-693-8600. In case of emergency, please call 309-645-3691 anytime, 24/7.
-
8/18/2019 Db-60 Manual 120811 Print
11/60
6
BEFORE INSTALLATION
The delivery service is responsible for damage occurring in transit. Dust Control Technology
CANNOT enter claims for damages. Contact your transportation agent for more information.
1. Inspect shipping containers for damage. Report damage to delivery service immediately
and fill out delivery service’s claim form. Keep any damaged goods subject to examination.
2. Remove the DustBoss unit from the shipping container and assemble by placing the
wheels on the carriage assembly (see fig.1–10 in the Appendix of Figures, p.16).
Turn off and lock out/tag out energy source to the DustBoss according to ANSI standards
prior to opening control panel or working on any electrical or mechanical components.
3. Move the DustBoss to a level, stable surface. Connect the DustBoss to both the
power supply and the water supply (see “Technical Specifications” section for the
electrical and water requirements of your unit).
Your personnel will need to determine the actual machine location, taking into consideration
factors such as wind direction, distance from water hydrant, whether or not the location
is open or closed, etc. Your company should develop procedures for machine positioning
and signage to designate the operating area of the unit.
> Remove the power cord a turn at a time, laying it coil upon coil on the ground in
an offset fashion until the appropriate length of cord required has been removed.The cord should uncoil without tangling as the end is pulled toward the power station.
> After checking to verify that the power station is switched off, connect the plug.
NOTE: If the plug will not go into the receptacle properly, clear away any ice, snow
or other debris. Keep the plug end out of water at all times. Again, be certain the
POWER IS SWITCHED OFF BEFORE CONNECTING THE PLUG.
> Hoses and power cords should be routed away from the spray plume and out of the
way from any vehicles. Advise vehicle operators of cord and hose locations. Signage
and/or fencing off of the operating area may be appropriate.
BEFORE USING
YOUR DUSTBOSS
Positioning of DustBoss
Prescreen filter
> Flush the water hose before attaching the hose to the unit. Open the water
hydrant/valve slowly, then turn off the water and reconnect the hose to the water
inlet on the machine.
> Rotate the head to direct the stream. Take advantage of wind to maximize coverage
and direction. Position the unit at an angle to the working area.
> Adjust the head to the appropriate angle for the wind and the area to be covered.
Cranking the vertical adjustment jack handle will change the head position.
4. Read the section entitled,“Operating the Unit,” thoroughly before starting and/or
attempting to use the DustBoss.
-
8/18/2019 Db-60 Manual 120811 Print
12/60
OPERATING THE UNIT
7
Turn off and lock out/tag out energy source to DustBoss according to ANSI standards
prior to opening control panel or working on any electrical or mechanical components
or removing safety guards or any items from cone.
Before starting the fan:
> Verify the master power switch is off.
> Verify the absence of any foreign object in the DustBoss fan housing.
The Master Electric Control Switch is positioned on the electrical panel. If turned off,
current is immediately suspended and the unit stops. Unit function commands on
panel include: Fan, on/off; Oscillator Motor, on/off; and High Pressure Pump, on/off.
Units equipped with optional increased oscillation have a knob for programming
the desired range of oscillation.
Hearing Protection is recommended if you are within 15 feet of the
SAFETY
UNIT
STARTUP
The Master Electric Control Switch is positioned on the electrical panel. If turned off,
current is immediately suspended and the unit stops. Unit function commands on control
CONTROL
PANEL
Control Panel
unit while in operation. Wear proper personal protective equipment.
When the DustBoss is in operation, keep away from the fan and
other moving parts. Never remove protective devices from the unit.
CHECKLIST:
> Make sure the machine is securely anchored. Lower the jacks to stabilize
the unit.
> Check fan to see if frozen or blocked by debris (with power off at machine).
> Loop the hose and power cord with extra slack to allow for the rotations of the
enclosure and fan barrel when the oscillator is engaged.
> Make sure water hose is securely connected. Verify the hose camlock rings on
the hose coupling are in locked position.
> Check that the DustBoss head is at an appropriate angle and aimed correctly.
> Verify the power is ON at the electrical station.
Before full start-up, check to be sure that the electrical system is operational by turning
the power on at the control panel. Push the fan start and stop button to ensure there isnot a serious fan imbalance or other operational problem within the system before full
speed rotation is allowed. At this time, check fan rotation. Before full start-up, be sure
no loose clothing, gloves, hats, etc. may be drawn into the fan.
Turn off and lock out/tag out energy source to DustBoss according to ANSI standards
prior to opening control panel or working on any electrical or mechanical components
or removing safety guards or any items from cone.
Stabilization Jack
Oscillation contr
knobs for units
equipped with op
increased oscilla
-
8/18/2019 Db-60 Manual 120811 Print
13/60
88
In case of danger, turn off Master Switch.
EMERGENCY SHUTDOWN PROCEDURE:
> Turn off Master Electric Control Switch.
> Shut off the booster pump and the water supply.
> Drain the water supply hose.
STANDARD SHUTDOWN PROCEDURE:
> Trouble-free start-up of your DustBoss relies upon the observance of the proper
shutdown procedure.
> Turn off water at hydrant/valve.
> After water is absent, disconnect hose and let drain downhill or off to the side.
> Turn off fan.
> Position head of machine to allow all water to drain. Tip it up as far as it can go.
> Turn machine disconnect switch to OFF position.
> Coil cord and place machine and hoses out of the way. Before moving the machine,
be sure the wheels and front tow bar are free to rotate.
If you experience unusual noise or vibration, shut the machine down immediately and
contact your local representative or Dust Control Technology directly at 800-707-2204
or 309-693-8600. In case of emergency, please call 309-645-3691 anytime, 24/7.
The DustBossunits can be raised and rotated to treat the operating area.
RAISING AND LOWERING:
> Elevation is manually controlled by the vertical adjustment jack.
> The angle of the DustBoss head is set by operator depending on weather
and environmental conditions and placement site.
> The ideal angle of elevation for maximum range is 35˚, for most applications.
MANUAL ROTATION:> The unit can rotate on the turntable a complete 360˚.
AUTOMATIC ROTATION:
> Be sure to unlock the turntable by removing the locking pin before beginning oscillation.
> The DustBoss will rotate back and forth automatically when the oscillator motor
is engaged (Standard DB-60: 0–40˚ of oscillating movement).
> Switching on the oscillating motor will begin the rotation of the unit head.
UNIT
SHUTDOWN
AIMING THE
DUSTBOSS
Vertical Adjustment Jack
-
8/18/2019 Db-60 Manual 120811 Print
14/60
9
HANDLING YOUR UNIT
9
Towing
The DustBoss units can be towed on a jobsite, however, they can not be towed on the
highway. The tires are for off-road use only. First lock the turn table head into position
using the locking pin.
To tow, simply attach the tow bar to the hitch on the transport equipment. A safety chain
is also recommended. Before moving a machine it is recommended that:
> The wheels are not frozen into the ground and free to rotate.
> The tow bar is locked into the up position on models having this feature.
> The leveling jacks are not frozen into the ground, are cleared from deep snow or mud
and are raised to prevent damage to them during transport.
Before towing a machine downhill, lock the tow bar pivot with the hitch pin provided to
prevent the machine from jack knifing during transport.
Anchoring
Be certain the jacks are firmly anchored to prevent machine movement. The machine must
be level for the oscillator to function properly. Remove the machine from the transport
equipment once you are sure it is secured into position.
Frame & Leveling Jacks
The DB-60 may be equipped with three leveling jacks that are quick and easy to adjust.
The jack has three points of adjustment:
> It is not critical that the unit be perfectly level. The jack is designed with a drop leg that
has five hole positions that are adjusted by pulling the pin and lowering or raising theleg to the desired height.
> The jack also has five tabs welded to the outside of the housing that enables height
adjustment in four positions simply by pulling the attached pin and lowering or raising
the jack to the desired position.
> Lastly, the jack has a telescoping feature that is adjusted up or down by turning the
handle located on the top of the jack.
Rear Axles
The rear axles are adjustable in and out. Extend to full out position for greater stability on
terrain when operating.
TRANSPORT ANDPOSITIONING
▲
Stabilization Jack
-
8/18/2019 Db-60 Manual 120811 Print
15/60
10
GALVANIZED CARRIAGE
Car
The DB-60 enclosure is attached to the frame with a large diameter turntable bearing. The
standard (40˚ oscillat ion) DB-60 is equipped with a friction clutch that enables the user to
adjust the location of the fan and where the mist falls while the oscillator gear motor is running.
However, for the friction clutch to function correctly it needs to be adjusted properly and the
machine must be level.
The friction clutch functions by compressing two discs constructed of a fibrous brake
material (“friction discs”) that apply a compressive force on a metallic drive member.
The drive member is coupled to the oscillator gear motor by a tie rod and two rod ends.
The rotation of the oscillator gear motor exerts a force on the tie rod assembly and drive
member that is held stationary by the friction clutch, causing the enclosure and fan torotate back and forth.
The friction clutch used on the standard (40˚ oscillat ion) DB-60 is shown below:
The torque is adjusted by bending down the ears on the locking washer and tightening
the adjustment nut to 1/2 turn past fingers tight. Depending on the wear to the friction
discs and your specific conditions it may be necessary to tighten the adjustment nut
beyond 1/2 turn beyond fingers tight. However, by overtightening adjustment nut, the
friction clutch will not function properly and maybe damaged. Please contact Dust Control
Technology for further assistance with friction clutch adjustment, if necessary.
All DB-60 carriage models are equipped with a transport lock to prevent the rotation or
movement of the enclosure and fan during transport. The transport lock should always be
used to move the machine to prevent a sudden weight shift from a rapid rotation of the
enclosure and fan and to prevent damage to the friction clutch.
MACHINE PIVOTING &
HEAD ADJUSTMENT
Transport Lock
riage Rotational Pivot and Friction Clutch Adjustment — Standard DB-60 (with 40˚ oscillation) only.
-
8/18/2019 Db-60 Manual 120811 Print
16/60
11
VERTICAL PIVOT ADJUSTMENT
The DB-60 is equipped with an easy-to-use head vertical adjustment jack. Crank the handle
to raise and lower the head angle. Varying the head angle can change the hang time of
the plume and provide better dust control, based on the conditions.
40˚ OSCILLATOR (STANDARD)
359˚ PROGRAMMABLE OSCILLATOR (OPTIONAL)
> Defining the Range of Oscillation (DEGREES)
The standard DB-60 is equipped with an oscillator to rotate the fan head back
and forth approximately 40˚ to allow for increased dust control. Units are also
available with optional 359˚ oscillation. The oscillator is engaged by simply
disengaging the transport locking pin and pushing the on/off button located
on the control panel.
Units equipped with optional increased oscillation (up to 359˚) also have an oscillation control
knob on the control panel that can be programmed to the desired range of oscillation.
1 Rotate the machine to one end of the desired range of oscillation by using the left/right
selector switch.
2
3
Turn selector switch to “set” and hold for 1/2 second.
Run the oscillator to the other end of the desired oscillation range, using the left/right selector
4 Turn selector to “set”. This must be done within 5 minutes of the first set.
5 Selector can now be moved to “run”; machine will oscillate between the set end points.
> Relocating the Position of the Oscillation Range
1 Stop the oscillator motor.
2
3
Lift the lever by the oscillator.
Reposition the barrel.
4 Lower the lever.
5 The machine will oscillate the same degree range, but starting from a new location.
TROUBLESHOOTING
NOTES
Machine will not oscillate: One“set” was pushed without the second “set” within
5 minutes. Repeat steps 1–5 above.>
> Oscillation range / position has changed: Machine was rotated manually using lever.
Repeat steps 1–5 above.
> Be certain to check that the machines can swing without interference to the unit.
> The carriage must be level and the friction clutch adjusted properly for the oscillator
to function as intended.
> During set-up, the hose and cord should be looped with extra slack to allow for the
rotation of the enclosure and fan barrel when the oscillator is engaged.
> The ducted fan can be rotated during operation to a different direction by simply turning
the enclosure. Dust Control Technology’s unique friction clutch allows this to occur
while the oscillator gear motor is engaged.
MACHINE PIVOTING &HEAD ADJUSTMENT
(continued)
Oscillator Motor
Oscillator Lever
Oscillation control knobs forunits equipped with optional
increased oscillation
Transport Locking Pin
-
8/18/2019 Db-60 Manual 120811 Print
17/60
12
STORAGE & MAINTENANCE
12
MACHINE STORAGE &PLACEMENT OPTIONS
Your company should determine the best location to store and operate the equipment
when the unit is in operation and when it is sitting idle. Proper marking and/or signage
to designate the location of the unit, and/or the use of fencing to cordon off the area
may be appropriate. Each company should have a policy that is clearly understood before
transporting, setting up, operating or parking the DustBoss.
Consider covering the water inlet to avoid entry of foreign objects. Be sure to follow the
winterizing checklist below if there is the possibility of freezing temperatures.
WINTERIZING RULESThe DustBoss can be operated below freezing temperatures,
however, when not in use, the following steps need to be
performed to avoid damage to your unit.
DB-60
> Disconnect the main inlet hose from the water supply.
> Release the drain valve under the high pressure pump.
Lever should be turned to the vertical position to drain.
> Turn the valve on the misting ring to the vertical position
to drain. Disconnect the black hose that leads from
the pump to the misting ring to drain using the
quickcam disconnect.
And remember...
> Protect your own hose from freezing as well.Quickcam Disconnect
High Pressure Pump
Drain Valve
▲
▲
-
8/18/2019 Db-60 Manual 120811 Print
18/60
13
QUARTERLY
MAINTENANCE
CHECKLIST
> No foreign material near electrical hookup.
> Cord intact and free of nicks or cracks.
> Fan free of obstructions and possible ice.
> Carriage not broken or cracked.
> Tow bar secure and not damaged.
> Hoses not damaged.
> Nozzles clear and undamaged.
> Nozzles — Inspect for any clogging.(If
clogged, take nozzle off at manifold while
the DustBoss is turned off. Use weld tip
cleaning rod to unplug.)
> Jack operating properly.
> No loose nuts or bolts.
> Wheel lug nuts secure.
> Tires properly inflated.
> Screen in place.
> Overall “look” is normal.
SPECIFICS TO CHECK:
> Wheels, tires, lug nuts and bearings.
> Carriage for weld cracks or bends.
> Tow bar for wear, cracks or bends.
> Head mounting yoke for wear, cracks
or bends.
> Nozzles checked for damage and wear.
> Manifold should be flushed clean.
> High pressure pump checked for damage
and wear.
> Fan housing and mounts inspected for
cracks or wear.
> Fan visually inspected for structural
cracks or nicks in blades.
> Electrical cord inspected for nicks and
abrasions or breakage.
> All nuts, bolts and other fasteners
checked for tightness.> Protect the cord from sunlight (ultraviolet
rays) to ensure its long life.
> Grease fan motor and booster pump
every 10,000 hours.
> Oscillator bearing should be greased on a regular
maintenance schedule, or as needed.
Recommended Spare Parts
> Nozzles.
Unclogged Nozzle
Nozzles
High Pressure Pump
Correct Nozzle Spray
DAILY CHECKLIST
The machine should be checked completely for unusual wear and/or damage
three times per year.
-
8/18/2019 Db-60 Manual 120811 Print
19/60
14
REMINDERS
DO’s
DON’Ts
REMEMBER’s
DO have a training seminar before you or your crew ever start to use the DustBoss.
Familiarity with the unit and its procedures could prevent a mishap or injury, and should
make dust control more efficient.
DO let vehicle operators know where and how the machines are placed so they can avoid
running over the cords, hoses and DustBoss plume area.
DO exercise caution and care when moving the DustBoss. THE LOCKING PIN ON THE
OSCILLATOR SHOULD BE ENGAGED WHEN MOVING THE UNIT AND DISENGAGED
WHEN IN USE.
DO check the machine frequently to determine if problems are developing that could
cause an emergency.
DO be sure to drain the machine at time of shutdown.
DO move the unit when the power source is off and the cord and hoses are disconnected.
DO keep good records of your activities. It can help you in the future. Examples include:
temperature, relative humidity, water flow rate, machine location, number of machines, etc.
DO plan the misting activities. Having a map of the area with a preset plan of action is a
good idea. Allow for changes according to various atmospheric changes and plan ahead,
setting up a timetable/schedule of where and when. Also consider how many people will
be available to monitor machine operation.
DO follow the instructions in this booklet, especially the daily checks and safety reminders.
DON’T trailer the DustBoss on the highway. The unit’s wheels are intended for off-road
use only.
DON’T connect or disconnect the unit from the electrical source while the power supply is on.
DON’T leave hoses or cords unprotected. They could be run over by vehicles and be
damaged or personnel could be injured.
DON’T straddle hoses.
DON’T stand in front of hydrants/valves or misting equipment while opening hydrants or valves.
DON’T turn off the valve with the booster pump running.
REMEMBER not to get in direct line of the DustBoss’s air stream. Debris could be thrown
by the fan and cause injury.
REMEMBER to raise the jacks on your machine when moving it.
-
8/18/2019 Db-60 Manual 120811 Print
20/60
15
ADDITIONAL RESOURCES
15
APPENDIX OF FIGURES ________________________________________________________________________16
OPTIONAL BOOSTER PUMP INFORMATION ______________________________________________________17–22
> Installation, Operation,
and Maintenance Instructions ____________________________________________________________17–18
> Pump Specifications ____________________________________________________________________19–20
> Repair Parts ______________________________________________________________________________21
> Parts Specifications ________________________________________________________________________22
ELECTRICAL SCHEMATICS____________________________________________________________________23–24
> DB-60 3-Phase Control Transformer Model (480 Volt / 60 Hertz machines) — Standard oscillation ____23
> DB-60 3-Phase Y-D Control Transformer Model (400 Volt / 50 Hertz machines)_____________________25
> DB-60 3-Phase Control Transformer Model (480 Volt / 60 Hertz machines) — 359˚ oscillation ________24
DB-60 PARTS LIST __________________________________________________________________________26–51
> Fan Assembly __________________________________________________________________________27–28
> Enclosure Assembly ____________________________________________________________________29–30
> Enclosure Assembly — 359º oscillation ____________________________________________________31–32
>
Frame Assembly________________________________________________________________________33–34
> Frame Assembly — 359º oscillation _______________________________________________________35–36
> Wheel Assembly________________________________________________________________________37–38
> Booster Pump & Spray Assembly _________________________________________________________39–40
> 359º Pump Assembly____________________________________________________________________41–42
> Y-Line Assembly ________________________________________________________________________43–44
> Oscillator Assembly _____________________________________________________________________45–46
> 359º Oscillator Assembly_________________________________________________________________47–48
> DB-60 Panel
_________________________________________________________51–52> DB-60 with 359º Oscillation Panel
___________________________________________________________________________49–50
WARRANTY __________________________________________________________________________________53
-
8/18/2019 Db-60 Manual 120811 Print
21/60
16
APPENDIX OF FIGURES
16
FIGS. 1–9Unpacking & Assembly of DB-60
-
8/18/2019 Db-60 Manual 120811 Print
22/60
17
-
8/18/2019 Db-60 Manual 120811 Print
23/60
1818
-
8/18/2019 Db-60 Manual 120811 Print
24/60
19
-
8/18/2019 Db-60 Manual 120811 Print
25/60
20
-
8/18/2019 Db-60 Manual 120811 Print
26/60
21
-
8/18/2019 Db-60 Manual 120811 Print
27/60
22
-
8/18/2019 Db-60 Manual 120811 Print
28/60
23
ELECTRICAL SCHEMATICS
DB-60 3-PHASE CONTROL TRANSFORMER MODEL – Standard oscillation
(480 Volt / 60 Hertz machines)
-
8/18/2019 Db-60 Manual 120811 Print
29/60
24
D B - 6 0 3 - P H A S E C O N T R O L T R A N S F O R M E R M O D E L – 3 5 9 ˚ o s c i l l a t i o n
( 4 8 0 V o l t /
6 0 H e r t z m a c h i n e s )
-
8/18/2019 Db-60 Manual 120811 Print
30/60
-
8/18/2019 Db-60 Manual 120811 Print
31/60
-
8/18/2019 Db-60 Manual 120811 Print
32/60
26
-
8/18/2019 Db-60 Manual 120811 Print
33/60
27
-
8/18/2019 Db-60 Manual 120811 Print
34/60
28
-
8/18/2019 Db-60 Manual 120811 Print
35/60
29
-
8/18/2019 Db-60 Manual 120811 Print
36/60
30
-
8/18/2019 Db-60 Manual 120811 Print
37/60
31
-
8/18/2019 Db-60 Manual 120811 Print
38/60
32
-
8/18/2019 Db-60 Manual 120811 Print
39/60
33
-
8/18/2019 Db-60 Manual 120811 Print
40/60
34
-
8/18/2019 Db-60 Manual 120811 Print
41/60
35
-
8/18/2019 Db-60 Manual 120811 Print
42/60
36
-
8/18/2019 Db-60 Manual 120811 Print
43/60
37
-
8/18/2019 Db-60 Manual 120811 Print
44/60
38
-
8/18/2019 Db-60 Manual 120811 Print
45/60
39
-
8/18/2019 Db-60 Manual 120811 Print
46/60
40
-
8/18/2019 Db-60 Manual 120811 Print
47/60
41
-
8/18/2019 Db-60 Manual 120811 Print
48/60
42
-
8/18/2019 Db-60 Manual 120811 Print
49/60
43
-
8/18/2019 Db-60 Manual 120811 Print
50/60
44
-
8/18/2019 Db-60 Manual 120811 Print
51/60
45
-
8/18/2019 Db-60 Manual 120811 Print
52/60
46
-
8/18/2019 Db-60 Manual 120811 Print
53/60
47
-
8/18/2019 Db-60 Manual 120811 Print
54/60
48
-
8/18/2019 Db-60 Manual 120811 Print
55/60
49
-
8/18/2019 Db-60 Manual 120811 Print
56/60
50
-
8/18/2019 Db-60 Manual 120811 Print
57/60
51
-
8/18/2019 Db-60 Manual 120811 Print
58/60
52
-
8/18/2019 Db-60 Manual 120811 Print
59/60
53
WARRANTY
A.THE WARRANTY PERIOD SHALL BE THIRTY-SIX MONTHS OR THREE THOUSAND HOURS
(WHICHEVER OCCURS FIRST) FROM THE DATE OF PURCHASE FOR ALL MODELS.
B.DURING THE PERIOD OF WARRANTY, DUST CONTROL TECHNOLOGY® GUARANTEES
TO THE ORIGINAL PURCHASER OF EACH DUST CONTROL MACHINE:
Any part adjudged by the manufacturer defective by reason of faulty workmanship
or material shall be replaced free of charge upon return of broken part.
C.THE WARRANTY SHALL BE EFFECTIVE IF PURCHASER:
Gives notice to an authorized distributor of any and all apparent defects within
ten (10) days after discovery and immediately makes machine available for inspection
to the distributor or his authorized representative.
D.WARRANTY SHALL NOT EXTEND TO:
1. Machines used for renting or leasing beyond the original owner.
2. Machines subjected to abnormal strain, neglect, abuse, improperly stored,
or altered from factory standard.
3. Machines whose trademark, name, or identification number has been changed
or removed.
4. Failures of, or failures caused by parts or accessories not manufactured by
Dust Control Technology®.
E.WHERE PERMITTED BY LAW:
1. COMPANY’S LIABILITY SHALL BE LIMITED TO THAT SET FORTH IN THIS
WARRANTY, AND COMPANY SHALL NOT BE LIABLE FOR INCIDENTAL OR
CONSEQUENTIAL DAMAGES, INCLUDING INJURY TO PERSON OR PROPERTY.
2. COMPANY MAKES NO OTHER WARRANTY OF ANY KIND, EXPRESSED OR
IMPLIED; AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE WHICH EXCEED THE OBLIGATION STATED IN THIS
WARRANTY ARE HEREBY DISCLAIMED BY COMPANY AND EXCLUDED FROM
THIS WARRANTY.
As set forth herein, the term “machine” shall refer to misting machines as manufactured by Dust Control
Technology and sold by authorized distributors. Claims for warranty shall be submitted by the authorized
distributor who performs or authorizes the repairs.
-
8/18/2019 Db-60 Manual 120811 Print
60/60