Transcript
Page 1: DC16 071A. 438-483 kW (500-540 kVA) · SCANIA POWER GENERATION ENGINEs DC16 071A. 438-483 kW (500-540 kVA) EU stage IIIA Standard equipment • Scania Engine Management System, EMS

SCANIA POWER GENERATION ENGINEs

DC16 071A. 438-483 kW (500-540 kVA)EU stage IIIA

Standard equipment• ScaniaEngineManagementSystem,EMS• Unitinjectors,PDE• Turbocharger• Fuelfilterandextrapre-filterwithwater

separator• Oilfilter,fullflow• Centrifugaloilcleaner• Oilcooler,integratedinblock• Oilfiller,invalvecover• Deepfrontoilsump• Oildipstick,inblock• Magneticdrainplugforoildraining• Starter,1-pole7.0kW• Alternator,1-pole100A• Flywheel,SAE14• Siluminflywheelhousing,SAE1flange• Front-mountedenginebrackets• EGRsystem• Opencrankcaseventilation• Operator’smanual

Optional equipment• Coolingpackage• Fans• Side-mountedPTO• Exhaustconnections• Instrumentpanel• Engineheater• Stiffrubberenginesuspension• Aircleaner• Closedcrankcaseventilation• Studsinflywheelhousing• Lowcoolantlevelreaction• Finetunepotentiometer• Rampstartdelay• Rampuprate

TheenginesforpowergenerationfromScaniaarebasedonarobustdesignwitha

strengthoptimisedcylinderblockcontainingwetcylinderlinersthatcaneasilybe

exchanged.Individualcylinderheadswith4valvespercylinderpromotesrepairability

andfueleconomy.

TheengineisequippedwithaScaniadevelopedEngineManagementSystem,EMS,

inordertoensurethecontrolofallaspectsrelatedtoengineperformance.

Theinjectionsystemisbasedonelectronicallycontrolledunitinjectorsthatgiveslow

exhaustemissionswithgoodfueleconomyandahightorque.Forfurtherreductionof

NOxemissionstheenginesarealsoequippedwithanexhaustgasrecirculation,EGR,

systemdevelopedbyScania.Theenginecanbefittedwithmanyaccessoriessuchas

aircleaners,radiatorsandPTOsinordertosuitavarietyofinstallations.

Thisspecificationmayberevisedwithoutnotice.

Engine speed (rpm)

1500 rpm (50 Hz) 1800 rpm (60 Hz)

PRP PRP

Grosspower(kW) 438 483

Grosspower(kVA) 500 540

Specfuelconsumption.Fullload(g/kWh) 204 211

Specfuelconsumption.3/4load(g/kWh) 210 213

Specfuelconsumption.1/2load(g/kWh) 211 215

Heatrejectiontocoolant(kW) 198 219

PRP – Prime power:Forcontinuousoperationatvaryingload.Maxmeanloadfactorof70%ofra-tedpowerover24hofoperation.1hour/12hoursperiodofaccumulatedpeakoverloadto110%.

Page 2: DC16 071A. 438-483 kW (500-540 kVA) · SCANIA POWER GENERATION ENGINEs DC16 071A. 438-483 kW (500-540 kVA) EU stage IIIA Standard equipment • Scania Engine Management System, EMS

SCANIA POWER GENERATION ENGINEs

sE 151 87 södertälje, swedenTelephone +46 8 553 810 00Telefax +46 8 553 829 [email protected]

DC16 071A. 438-483 kW (500-540 kVA)EU stage IIIA

Edit

ion

03

© s

can

ia C

V A

B, s

E-15

1 87

der

tälje

, sw

eden

Engine description

Noofcylinders 90ºV8

Workingprinciple 4-stroke

Firingorder 1-5-4-2-6-3-7-8

Displacement 16.4litres

Borexstroke 130x154mm

Compressionratio 16.7:1

Weight 1340kg(excloilandcoolant)

Pistonspeedat1500rpm 7.7m/s

Pistonspeedat1800rpm 9.24m/s

Camshaft Highpositionalloysteel

Pistons Steelpistons

Connectionrods I-sectionpressforgingsofalloysteel

Crankshaft Alloysteelwithhardenedandpolishedbearingsurfaces

Oilcapacity 35-45dm3

Electricalsystem 1-pole24V

1:70

901:

7092

1315

560 651

843

445

All dimensions in mm