SS-DCC15 www.daikinac.com 12/17Supersedes 7/17
15 Tons Cooling Capacity: 180,000 BTU/h20 Tons Cooling Capacity: 240,000 BTU/h25 Tons Cooling Capacity: 290,000 BTU/h
DCC Commercial15 - 25 Tons Packaged Air Conditioners
■ Standard Features• High-efficiency scroll compressor• Copper tube / aluminum fin coils• Aluminum micro-channel
indoor coil on 25-ton units• 25-ton models contain two outdoor fans• High- and low-pressure switches• High-capacity, steel-cased filter drier• Heater kits with single-point entry • Crankcase heaters • 24-volt terminal strip • Power block for field wiring
■ Cabinet Features• Heavy-gauge, galvanized-steel cabinet
with UV-resistant powder-paint finish • Built-in filter rack with standard 2”
filters (convertible to 4” filters)• Full perimeter rail• Sloped drain pan
• Units meet the performance outlined in Table 6.8.1-1 of ASHRAE Standard 90.1-2013
• AHRI Certified; ETL Listed
* Complete warranty details available from your local dealer or at www.daikincomfort.com.
■ ContentsNomenclature ...............................2Product Specifications ..................4Expanded Cooling Data .................7Airflow Data ................................13Crankcase Heater ........................15Electrical Data / Heat Kit Data ....16Dimensions ..................................20Wiring Diagrams .........................25 – for Models with DDC Controls ......28Accessories .................................32
2 www.daikinac.com SS-DCC15 SS-DCC15 www.daikinac.com 3
Nomenclature
D C C 300 060 3 B * * * A *1 2 3 4,5,6 7,8,9 10 11 12 13 14 15 16
Revision LevelsMajor & Minor
Brand Factory-Installed OptionsD Daikin X No Options
A Non-powered convenience outletConfiguration B Powered convenience outletC Standard Efficiency (6 - 25 Tons) C Low-ambient kitS Standard Efficiency (3 - 5 Tons) D Return air smoke detectorT High Efficiency (3 - 5 Tons) E Supply air smoke detector
F Non-powered convenience outlet; Application Low-ambient kitC Cooling1 G Non-powered convenience outlet; G Gas Heat Return air smoke detectorH Heat Pump1 H Non-powered convenience outlet;
Supply air smoke detectorNominal Cooling Capacity J Non-powered convenience outlet;036 3 Tons 102 8½ Tons 300 25 Tons Return & Supply air smoke detectors048 4 Tons 120 10 Tons K Non-powered convenience outlet;060 5 Tons 150 12½ tons Low-ambient kit; Supply air smoke detector072 6 Tons 180 15 Tons L Non-powered convenience outlet; 090 7½ Tons 240 20 Tons Low-ambient kit
Return & Supply air smoke detectorsNominal Heating Capacity M Powered convenience outlet;
Gas/Electric A/C H/P Factory-Installed Electric Heat Low-ambient kit045 45,000 BTU/h XXX No Heat N Powered convenience outlet;090 90,000 BTU/h 010 10 kW 030 30 kW Return air smoke detector115 115,000 BTU/h 015 15 kW 031 30 kW O Powered convenience outlet;140 140,000 BTU/h 016 15 kW 045 45 kW Return & Supply air smoke detectors210 210,000 BTU/h 018 18 kW 046 45 kW P Powered convenience outlet;350 350,000 BTU/h 020 20 kW 060 60 kW Supply air smoke detector400 400,000 BTU/h 025 25 kW Q Powered convenience outlet; Low-ambient
See product specifications for heat size(s) available for each capacity. kit; Return air smoke detectorR Powered convenience outlet; Low-ambient
Voltage kit; Supply air smoke detector1 208-230/1/60 4 460/3/60 T Powered convenience outlet; Low-ambient3 208-230/3/60 7 575/3/60 kit; Return & Supply air smoke detectors
U Non-powered convenience outlet;Supply Fan/Drive Type/Motor Low-ambient kit; Return air smoke detectorD Direct Drive (3-5 Tons) V Low-ambient kit; Return air smoke detectorV Two-Speed Belt Drive (also designates 6-Ton with two-stage compressor) W Low-ambient kit; Supply air smoke detectorW High Static (two-speed Belt Drive) Y Low-ambient kit; Return & Supply
air smoke detectorsA Ultra Low-Leak Downflow Economizer R Ultra Low-Leak Downflow Economizer; Z Return & Supply air smoke detectorsB DDC-BACnet protocol DDC-BACnet protocol; F Ultra Low-Leak Downflow Economizer; Disconnect Switch (non-fused)
DDC-BACnet protocol V Low-Leak Downflow Economizer Factory-Installed OptionsH Disconnect Switch (non-fused) W Low-Leak Downflow Economizer X Standard Aluminized Heat ExchangerJ Ultra Low-Leak Downflow Economizer; Disconnect Switch (non-fused) S Stainless-Steel Heat Exchanger
Disconnect Switch (non-fused) X No Options D Hinged PanelsM Disconnect Switch (non-fused); DDC-BACnet protocol K Stainless-Steel Heat Exchanger;
Hinged PanelsNote: Not all options available for all products. B Phase Monitor
1 X= No Options in character 13th J Stainless Steel Heat Exchanger; Phase MonitorM Hinged Panel; Phase MonitorL Stainless-Steel Heat Exchanger;
Hinged Panels; Phase Monitor
2 www.daikinac.com SS-DCC15 SS-DCC15 www.daikinac.com 3
Nomenclature
Factory-Installed Options• Stainless-Steel Heat Exchanger (Gas units only): A tubular heat exchanger made of 409-type stainless steel is installed in the unit.• Low-Ambient Kit: Allows for cooling operation at lower outdoor temperatures. On the 3- to 6-ton units, cooling operation is extended
from 60°F ambient temperature to 35°F outside air temperature. On 7½ -20 ton units, cooling operation is extended from 35°F ambient temperature to 0°F outside air temperature. For 25 ton units, cooling operation is extended from 24°F ambient temperature to 0°F outside air temperature.
• Economizers (Downflow): Based on air conditions, can provide outside air to cool the space.• Electric Heat Kits (AC and heat pump units only): Available in all voltage options.• Non-powered Convenience Outlet: A 120V, 15A, GFCI outlet makes it easier for technicians to service the unit once an electrician runs
power to the outlet.• Powered Convenience Outlet: A 120V, 15A, GFCI outlet powered with a transformer built into the unit. When a factory-installed powered
convenience outlet is installed in the equipment, the unit MCA (Min. Circuit Ampacity) will increase by 7.2A/6.5A for 208/230V units, increase by 3.3A for 460V units, and by 2.6A for 575V units. The MOP (Max. Overcurrent Protection) device must be sized accordingly.
• Disconnect Switch (non-fused; 3-phase units only): A disconnect switch is installed in the unit and factory wiring will be complete from the switch to the unit. Please note that for air conditioning (DSC units) and heat pump models (DSH units), the appropriate electric heat kit must be ordered to be factory-installed along with the disconnect switch (non-fused) when it is ordered. Please note that for models with a powered convenience outlet option and a disconnect switch (non-fused) option, the power to the powered convenience outlet will be shut off when the disconnect switch (non-fused) is in the off position.
• Return Air and/or Supply Air Smoke Detectors: Return air and/or supply air smoke detectors are installed in the unit.• Hinged Access Panels: Allows access to unit’s major components. Combined with latches for easy access to control box, compressor,
filters and blower motor. Available on all units.• Two-speed indoor fan blower models are standard on 6, 7½, 8½, 10, 12½, 15, 20 & 25 ton units. Section 6.4.3.10.b of ASHRAE Standard
90.1-2010 and Section 6.5.3.2.1.a of ASHRAE Standard 90.1-2013 require a minimum of two fan speeds. Section 140.4(m)1 of California Energy Commission Title 24 2013 contains a similar provision. When the units with the two-speed indoor fan blowers operate on a call for the first stage of cooling, the fan operates at low speed, which is 66% of full speed. When the units operate on a call for the second stage of cooling, the fan operates at full speed. In heating operation, the fan operates at full speed. During ventilation operation, the fan operates at low speed.
• Phase Monitor: Phase monitor (3 phase only), available for 3 - 25 ton DS, DC and DT series models. Phase monitor shall provide protection for motors and compressors against problems caused by phase loss, phase reversal and phase unbalance. Phase monitor is equipped with an LED that provides an ON or FAULT indicator.
• DDC Controller: DDC communicating controller, available for 3 - 25 ton DS, DC and DT series models with on-board BACnet® communication interface.
• High static blower assembly, factory-installed
4 www.daikinac.com SS-DCC15 SS-DCC15 www.daikinac.com 5
Product Specifications — 15 Tons
DCC180*** 4V***A*
DCC180*** 7B***A*
DCC180*** 7V***A*
Cooling Capacity
Total, BTU/h 180,000 180,000 180,000
Sensible BTU/h 134,600 134,600 134,600
EER / IEER 11 / 12.8 11 / 11.2 11 / 12.8
Decibels 88 88 88
ARI Reference #s 6502018 6572288 6502018
Evaporator Motor / Coil
Motor Type (Belt Drive) 2-Speed Belt Std Static 2-Speed Belt
Indoor Nominal CFM 6,000 6,000 6,000
Indoor Motor FLA (Cooling) 4.3 4.2 3.5
Horsepower - RPM (Speed: Full / Low) 3.0 - 1,760/1,165 3.0 - 1,725 3.0 - 1,760/1,165
Metering Device TXV TXV TXV
Filter Size (#) 20 x 25 x 2 (6) 20 x 25 x 2 (6) 20 x 25 x 2 (6)
Drain Size (NPT) 1” 1” 1”
R-410A Refrigerant Charge Cir #1 186.2 186.2 186.2
R-410A Refrigerant Charge Cir #2 170.8 170.8 170.8
Evaporator Coil Face Area (ft²) 20 20 20
Rows Deep / Fins per Inch 4 / 16 4 / 16 4 / 16
Belt Drive Evap Fan Data
# of Wheels (D x W) 2 (15” x 12”) 2 (15” x 12”) 2 (15” x 12”)
Motor Sheave 1VP50 x 1⅛” 1VM50 x ⅞” 1VP50 x 1⅛”
Blower Sheave BK100 x 1³/₁₆” BK100 x 1³/₁₆” BK100 x 1³/₁₆”
Belt BX44 BX45 BX44
Condenser Fan / Coil
Quantity of Condenser Fan Motors 3 3 3
Horsepower - RPM ⅓ - 1,075 ⅓ - 1,075 ⅓ - 1,075
Fan Diameter / # Fan Blades 22 / 3 22 / 3 22 / 3
Outdoor Nominal CFM 9,000 9,000 9,000
Face Area (ft²) 53.3 53.3 53.3
Rows Deep / Fins per Inch 2 / 27 2 / 27 2 / 27
Compressor
Quantity / Type 2 / Scroll 2 / Scroll 2 / Scroll
Compressor RLA / LRA Circuit #1 12.2 / 100 9.0 / 78 9.0 / 78
Compressor RLA / LRA Circuit #2 12.2 / 100 9.0 / 78 9.0 / 78
Electrical Data / Static
Voltage / Phase (60 Hz) 460-3-60 575-3-60 575-3-60
Standard Max Static 1.2 1.2 1.2
Outdoor Fan FLA / LRA 0.85 / 2.2 0.67/1.8 0.67/1.8
Total Unit Amps 31.3 24.2 23.5
Min. Circuit Ampacity¹ 34.3 26.4 25.7
Max. Overcurrent Protection (amps)² 45 35 30
Entrance Power Supply 2⅛" 2⅛" 2⅛"
Entrance Control Voltage ⅞" ⅞" ⅞"
Operating Weight (lbs) 1965 1965 1965
Ship Weight (lbs) 2080 2080 2080
¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
² May use fuses or HACR-type circuit breakers of the same size as noted.Note: Always check the S&R plate for electrical data on the unit being installed.
4 www.daikinac.com SS-DCC15 SS-DCC15 www.daikinac.com 5
Product Specifications — 20 Tons
DCC240 ***3V***B*
DCC240 ***4V***B*
DCC240 ***7V***B*
Cooling Capacity
Total, BTU/h 240,000 240,000 240,000
Sensible BTU/h 181,000 181,000 181,000
EER / IEER 10.0 / 11.6 10.0 / 11.6 10.0 / 11.6
Decibels 88 88 88
ARI Reference #s 8813880 8813880 8813880
Evaporator Motor / Coil
Motor Type (Belt Drive) 2-Speed Belt 2-Speed Belt 2-Speed Belt
Indoor Nominal CFM 7,000 7,000 7,000
Indoor Motor FLA (Cooling) 14 6.6 5.2
Horsepower - RPM (Speed: Full / Low) 5.0 - 1,775/1,185 5.0 - 1,775/1,185 5.0 - 1,775/1,185
Metering Device TXV TXV TXV
Filter Size (#) 20 x 25 x 2 (6) 20 x 25 x 2 (6) 20 x 25 x 2 (6)
Drain Size (NPT) 1” 1” 1”
R-410A Refrigerant Charge Cir #s 1 & 2 177 & 195 ozs. 177 & 195 ozs. 177 & 195 ozs.
Face Area (ft²) 20 20 20
Rows Deep / Fins per Inch 4 / 16 4 / 16 4 / 16
Belt Drive Evap Fan Data
# of Wheels (D x W) 2 (15” x 15”) 2 (15” x 15”) 2 (15” x 15”)
Motor Sheave 1VP60 x 1⅜” 1VP60 x 1⅜” 1VP60 x 1⅜”
Blower Sheave BK100 x 1⁷/₁₆” BK100 x 1⁷/₁₆” BK100 x 1⁷/₁₆”
Belt BX45 BX45 BX45
Condenser Fan / CoilQuantity of Condenser Fan Motors 3 3 3
Horsepower - RPM ⅓ - 1,075 ⅓ - 1,075 ⅓ - 1,075
Fan Diameter / # Fan Blades 22 / 3 22 / 3 22 / 3
Outdoor Nominal CFM 9,000 9,000 9,000
Face Area (ft²) 53.3 53.3 53.3
Rows Deep / Fins per Inch 2 / 27 2 / 27 2 / 27
CompressorQuantity / Type 2 / Scroll 2 / Scroll 2 / Scroll
Compressor RLA / LRA CIR. #1 34.0 / 240.0 16.0 / 140.0 12.9 / 107.6
Compressor RLA / LRA CIR. #2 34.0 / 240.0 16.0 / 140.0 12.9 / 107.6
Electrical Data / Static
Voltage / Phase (60 Hz) 208/230-3-60 460-3-60 575-3-60
Outdoor Fan FLA / LRA 2.0 /4.4 0.85 / 2.2 0.67 / 1.8
Total Unit Amps 88 41.2 33.0
Min. Circuit Ampacity¹ 96.4 / 96.4 43.5 35.0
Max. Overcurrent Protection (amps)² 125 / 125 50 45
Entrance Power Supply 2⅛" 2⅛" 2⅛"
Entrance Control Voltage ⅞" ⅞" ⅞"
Operating Weight (lbs) 2085 2085 2085
Ship Weight (lbs) 2202 2202 2202
¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.² May use fuses or HACR-type circuit breakers of the same size as noted.Note: Always check the S&R plate for electrical data on the unit being installed.
6 www.daikinac.com SS-DCC15 SS-DCC15 www.daikinac.com 7
Product Specifications — 25 Tons
DCC300***3V***A*
DCC300***4V***A*
DCC300***7V***A*
Cooling Capacity
Total, BTU/h 290,000 290,000 290,000
Sensible BTU/h 196,000 196,000 196,000
EER / IEER 10.2 / 11.8 10.2 / 11.8 10.2 / 11.8
Decibels 92 92 92
AHRI Reference #s 8582013 8582013 8582013
Evaporator Motor / Coil
Motor Type (Belt Drive) 2-speed Belt Drive 2-speed Belt Drive 2-speed Belt Drive
Indoor Nominal CFM 8,200 8,200 8,200
Indoor Motor FLA (Cooling) 21.0 10.1 8.2
Horsepower - RPM (Speed: Full / Low) 7.5 - 1770/1175 7.5 - 1770/1175 7.5 - 1770/1175
Metering Device TXV TXV TXV
Filter Size (#) 20 x 20 x 2 (8) 20 x 20 x 2 (8) 20 x 20 x 2 (8)
Drain Size (NPT) 1" 1" 1"
R-410A Refrigerant Charge Cir #s 1 & 2 215 & 198 ozs. 215 & 198 ozs. 215 & 198 ozs.
Face Area (ft²) 17.2 17.2 17.2
Rows Deep / Fins per Inch 2 / 15 2 / 15 2 / 15
Belt Drive Evap Fan Data
# of Wheels (D x W) 2 (15" x 15") 2 (15" x 15") 2 (15" x 15")
Motor Sheave 1VP60 x 1⅜" 1VP60 x 1⅜" 1VP60 x 1⅜"
Blower Sheave BK110 x 1⁷/₁₆" BK110 x 1⁷/₁₆" BK110 x 1⁷/₁₆"
Belt BX46 BX46 BX46
Condenser Fan / Coil
Quantity of Condenser Fan Motors 2 2 2
Horsepower - RPM 1 - 1145 1 - 1145 1 - 1145
Fan Diameter / # Fan Blades 30 / 2 30 / 2 30 / 2
Outdoor Nominal CFM 15,000 15,000 15,000
Face Area (ft²) 53.3 53.3 53.3
Rows Deep / Fins per Inch 2 / 27 2 / 27 2 / 27
Compressor
Quantity / Type 2 / Scroll 2 / Scroll 2 / Scroll
Compressor RLA / LRA CIR. #1 48.1 / 245 18.6 / 125 14.7 / 100
Compressor RLA / LRA CIR. #2 48.1 / 245 18.6 / 125 14.7 / 100
Electrical Data
Voltage / Phase (60 Hz) 208/230-3-60 460-3-60 575-3-60
Outdoor Fan FLA / LRA 3.7 / 16.9 1.85 / 8.5 1.5 / 6.82
Total Unit Amps 125 51.0 40.6
Min. Circuit Ampacity¹ 133 / 133 53.8 42.9
Max. Overcurrent Protection (amps)² 175 / 175 70 50
Entrance Power Supply 2⅛" 2⅛" 2⅛"
Entrance Control Voltage ⅞" ⅞" ⅞"
Operating Weight (lbs) 2119 2119 2119
Ship Weight (lbs) 2387 2387 2387
¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
² May use fuses or HACR-type circuit breakers of the same size as noted.Note: Always check the S&R plate for electrical data on the unit being installed.
6 www.daikinac.com SS-DCC15 SS-DCC15 www.daikinac.com 7
Out
door
Am
bien
t Te
mpe
ratu
re
6575
8595
105
115
Ente
ring
Indo
or W
et B
ulb
Tem
pera
ture
IDB
Airf
low
5963
6771
5963
6771
5963
6771
5963
6771
5963
6771
5963
6771
70
6750
MBh
176.
418
2.8
200.
3-
172.
317
8.6
195.
6-
168.
217
4.3
191.
0-
164.
117
0.1
186.
3-
155.
916
1.6
177.
0-
144.
414
9.7
164.
0-
S/T
0.75
0.63
0.43
-0.
780.
650.
45-
0.80
0.67
0.46
-0.
820.
690.
48-
0.86
0.71
0.49
-0.
860.
720.
50-
∆T18
1612
-18
1612
-18
1612
-18
1612
-18
1612
-17
1511
-
HI P
R23
625
326
8-
264
284
300
-30
132
334
2-
342
368
389
-38
541
443
8-
425
458
484
-
LO P
R10
311
012
0-
109
116
127
-11
412
113
2-
119
127
139
-12
513
314
5-
129
138
150
-
6000
MBh
171.
217
7.5
194.
5-
167.
317
3.4
189.
9-
163.
316
9.2
185.
4-
159.
316
5.1
180.
9-
151.
315
6.9
171.
9-
140.
214
5.3
159.
2-
S/T
0.72
0.60
0.41
-0.
740.
620.
43-
0.76
0.64
0.44
-0.
790.
660.
45-
0.82
0.68
0.47
-0.
820.
690.
48-
∆T19
1612
-19
1613
-19
1613
-19
1713
-19
1612
-18
1512
-
HI P
R23
325
126
5-
262
282
297
-29
832
033
8-
339
365
385
-38
141
043
3-
421
453
479
-
LO P
R10
210
911
9-
108
115
126
-11
212
013
1-
118
126
137
-12
413
214
4-
128
136
149
-
4800
MBh
158.
116
3.8
179.
5-
154.
416
0.0
175.
3-
150.
715
6.2
171.
1-
147.
015
2.4
167.
0-
139.
714
4.8
158.
6-
129.
413
4.1
146.
9-
S/T
0.69
0.58
0.40
-0.
720.
600.
41-
0.73
0.61
0.42
-0.
760.
630.
44-
0.79
0.66
0.46
-0.
790.
660.
46-
∆T21
1814
-21
1814
-21
1814
-21
1814
-21
1814
-20
1713
-
HI P
R22
624
325
7-
254
273
288
-28
931
132
8-
329
354
374
-37
039
842
0-
409
440
464
-
LO P
R99
106
115
-10
511
212
2-
109
116
127
-11
512
213
3-
120
128
139
-12
413
214
4-
75
6750
MBh
179.
418
4.7
199.
921
4.5
175.
218
0.4
195.
320
9.6
171.
017
6.1
190.
620
4.6
166.
917
1.8
186.
019
9.6
158.
516
3.2
176.
718
9.6
146.
815
1.2
163.
617
5.6
S/T
0.85
0.76
0.58
0.37
0.89
0.79
0.60
0.39
0.91
0.81
0.61
0.40
0.94
0.84
0.63
0.41
0.97
0.87
0.66
0.42
0.98
0.88
0.66
0.43
∆T21
1916
1121
1916
1121
1916
1121
2016
1121
1916
1120
1815
10
HI P
R23
825
627
028
226
728
730
331
630
432
734
536
034
637
239
341
038
941
944
246
143
046
348
850
9
LO P
R10
411
112
112
911
011
712
813
711
512
213
314
212
112
814
014
912
613
414
715
613
113
915
216
2
6000
MBh
174.
217
9.3
194.
120
8.3
170.
117
5.1
189.
620
3.5
166.
117
1.0
185.
119
8.6
162.
016
6.8
180.
519
3.8
153.
915
8.5
171.
518
4.1
142.
614
6.8
158.
917
0.5
S/T
0.81
0.73
0.55
0.35
0.84
0.76
0.57
0.37
0.87
0.77
0.59
0.38
0.89
0.80
0.60
0.39
0.93
0.83
0.63
0.40
0.94
0.84
0.63
0.41
∆T22
2016
1122
2017
1122
2017
1122
2017
1222
2016
1120
1915
11
HI P
R23
625
326
827
926
428
430
031
330
132
334
235
634
236
838
940
638
541
543
845
742
645
848
450
4
LO P
R10
311
012
012
810
911
612
713
511
412
113
214
111
912
713
914
812
513
314
515
512
913
815
016
0
4800
MBh
160.
716
5.5
179.
119
2.3
157.
016
1.6
175.
018
7.8
153.
315
7.8
170.
818
3.3
149.
515
4.0
166.
617
8.8
142.
014
6.3
158.
316
9.9
131.
613
5.5
146.
615
7.4
S/T
0.79
0.70
0.53
0.34
0.81
0.73
0.55
0.35
0.83
0.75
0.56
0.36
0.86
0.77
0.58
0.38
0.89
0.80
0.61
0.39
0.90
0.81
0.61
0.39
∆T24
2218
1324
2318
1325
2318
1325
2319
1324
2218
1323
2117
12
HI P
R22
824
626
027
125
627
629
130
429
231
433
134
633
235
737
739
437
440
242
544
341
344
446
948
9
LO P
R10
010
711
712
410
611
312
313
111
011
712
813
611
612
313
414
312
112
914
115
012
513
314
615
5
IDB:
Ent
erin
g In
door
Dry
Bul
b Te
mpe
ratu
reSh
aded
are
a re
flect
s ACC
A (T
VA) c
ondi
tions
High
and
low
pre
ssur
es a
re m
easu
red
at th
e liq
uid
and
sucti
on a
cces
s fitti
ngs.
Expanded Cooling Data — 15 Tons (Standard motor and two-speed motor at high speed)
8 www.daikinac.com SS-DCC15 SS-DCC15 www.daikinac.com 9
Expanded Cooling Data — 15 Tons (Two-speed motor at high speed)
Out
door
Am
bien
t Te
mpe
ratu
re
6575
8595
105
115
Ente
ring
Indo
or W
et B
ulb
Tem
pera
ture
IDB
Airf
low
5963
6771
5963
6771
5963
6771
5963
6771
5963
6771
5963
6771
80
6750
MBh
182.
618
6.5
199.
321
3.1
178.
318
2.2
194.
720
8.1
174.
117
7.9
190.
020
3.1
169.
817
3.5
185.
419
8.2
161.
316
4.9
176.
118
8.3
149.
415
2.7
163.
217
4.4
S/T
0.94
0.88
0.71
0.53
0.97
0.91
0.74
0.55
1.00
0.93
0.76
0.57
1.00
0.96
0.78
0.59
1.00
1.00
0.81
0.61
1.00
1.00
0.82
0.61
∆T23
2219
1624
2320
1624
2320
1623
2320
1622
2220
1620
2118
15
HI P
R24
025
927
328
527
029
030
632
030
733
034
936
334
937
639
741
439
342
344
746
643
446
749
351
5
LO P
R10
611
212
313
111
211
913
013
811
612
313
514
312
213
014
115
112
813
614
815
813
214
015
316
3
6000
MBh
177.
218
0.1
193.
520
6.9
173.
117
6.9
189.
020
2.0
169.
017
2.7
184.
519
7.2
164.
916
8.5
180.
019
2.4
156.
616
0.1
171.
018
2.8
145.
114
8.3
158.
416
9.3
S/T
0.89
0.84
0.68
0.51
0.93
0.87
0.71
0.53
0.95
0.89
0.72
0.54
0.98
0.92
0.75
0.56
1.00
0.95
0.78
0.58
1.00
0.96
0.78
0.59
∆T24
2320
1625
2420
1625
2420
1625
2421
1624
2320
1622
2219
15
HI P
R23
825
627
028
226
728
730
331
630
432
734
536
034
637
239
341
038
941
944
246
143
046
348
851
0
LO P
R10
511
112
112
911
011
712
813
711
512
213
314
212
112
814
014
912
613
414
715
613
113
915
216
2
4800
MBh
163.
616
7.2
178.
619
0.9
159.
816
3.3
174.
418
6.5
156.
015
9.4
170.
318
2.0
152.
215
5.5
166.
117
7.6
144.
614
7.7
157.
816
8.7
133.
913
6.8
146.
215
6.3
S/T
0.86
0.81
0.66
0.49
0.89
0.84
0.68
0.51
0.92
0.86
0.70
0.52
0.94
0.89
0.72
0.54
0.98
0.92
0.75
0.56
0.99
0.93
0.75
0.56
∆T27
2622
1827
2623
1827
2623
1828
2623
1827
2623
1825
2421
17
HI P
R23
124
826
227
425
927
929
430
729
531
733
534
933
536
138
139
837
740
642
944
741
744
947
449
4
LO P
R10
110
811
812
510
711
412
413
211
111
812
913
811
712
413
614
512
313
014
215
212
713
514
715
7
85
6750
MBh
185.
818
9.3
198.
321
1.6
180.
418
4.9
193.
720
6.6
177.
118
0.5
189.
120
1.7
172.
817
6.1
184.
519
6.8
164.
216
7.3
175.
218
7.0
152.
115
5.0
162.
317
3.2
S/T
0.98
0.95
0.86
0.69
1.00
0.98
0.89
0.72
1.00
1.00
0.91
0.74
1.00
1.00
0.94
0.76
1.00
1.00
0.97
0.79
1.00
1.00
0.98
0.80
∆T25
2423
2025
2523
2024
2523
2024
2424
2022
2323
2021
2122
19
HI P
R24
326
127
628
827
229
330
932
331
033
335
236
735
338
040
141
839
742
745
147
043
947
249
852
0
LO P
R10
711
312
413
211
312
013
113
911
712
513
614
512
313
114
315
212
913
715
015
913
314
215
516
5
6000
MBh
180.
318
3.8
192.
520
5.4
176.
117
9.6
188.
120
0.6
172.
017
5.3
183.
619
5.8
167.
817
1.0
179.
119
1.1
159.
416
2.5
170.
118
0.5
147.
615
0.5
157.
616
8.1
S/T
0.94
0.90
0.82
0.66
0.97
0.94
0.85
0.69
1.00
0.96
0.87
0.70
1.00
0.99
0.89
0.73
1.00
1.00
0.93
0.75
1.00
1.00
0.94
0.76
∆T26
2524
2126
2624
2126
2624
2126
2625
2124
2524
2123
2323
20
HI P
R24
025
927
328
527
029
030
632
030
733
034
936
334
937
639
741
439
342
344
746
643
446
749
351
5
LO P
R10
611
212
313
111
211
913
013
811
612
313
514
312
213
014
115
112
813
614
815
813
214
015
316
3
4800
MBh
166.
516
9.7
177.
718
9.6
162.
616
5.7
173.
618
5.2
158.
716
1.8
169.
418
0.8
154.
815
7.8
165.
317
6.4
147.
114
9.9
157.
016
7.5
136.
313
8.9
145.
515
5.2
S/T
0.90
0.87
0.79
0.64
0.94
0.90
0.81
0.66
0.96
0.93
0.84
0.68
0.99
0.96
0.86
0.70
1.00
0.99
0.90
0.73
1.00
1.00
0.90
0.73
∆T29
2827
2329
2927
2329
2927
2329
2927
2428
2827
2326
2725
22
HI P
R23
325
126
527
626
228
129
731
029
732
033
835
333
936
538
540
238
141
043
345
242
145
347
949
9
LO P
R10
210
911
912
710
811
512
613
411
212
013
113
911
812
613
714
612
413
214
415
312
813
614
915
8
IDB:
Ent
erin
g In
door
Dry
Bul
b Te
mpe
ratu
reSh
aded
are
a re
flect
s AHR
I (TV
A) co
nditi
ons
High
and
low
pre
ssur
es a
re m
easu
red
at th
e liq
uid
and
sucti
on a
cces
s fitti
ngs.
8 www.daikinac.com SS-DCC15 SS-DCC15 www.daikinac.com 9
Out
door
Am
bien
t Te
mpe
ratu
re
6575
8595
105
115
Ente
ring
Indo
or W
et B
ulb
Tem
pera
ture
IDB
Airf
low
5963
6771
5963
6771
5963
6771
5963
6771
5963
6771
5963
6771
70
7875
MBh
235.
224
3.8
267.
1-
229.
723
8.1
260.
9-
224.
223
2.4
254.
6-
218.
822
6.8
248.
4-
207.
821
5.4
236.
0-
192.
519
9.5
218.
6-
S/T
0.76
0.63
0.44
-0.
780.
660.
45-
0.80
0.67
0.47
-0.
830.
690.
48-
0.86
0.72
0.50
-0.
870.
730.
50-
∆T21
1814
-21
1814
-21
1814
-21
1814
-21
1814
-20
1713
-
HI P
R25
927
929
4-
290
313
330
-33
035
637
5-
376
405
428
-42
345
648
1-
468
503
531
-
LO P
R10
010
611
6-
105
112
122
-11
011
712
7-
115
122
134
-12
112
814
0-
125
133
145
-
7000
MBh
228.
323
6.7
259.
3-
223.
023
1.2
253.
3-
217.
722
5.7
247.
2-
212.
422
0.1
241.
2-
201.
820
9.1
229.
1-
186.
919
3.7
212.
3-
S/T
0.72
0.60
0.42
-0.
750.
630.
43-
0.77
0.64
0.44
-0.
790.
660.
46-
0.82
0.69
0.48
-0.
830.
690.
48-
∆T22
1914
-22
1914
-22
1914
-22
1915
-22
1914
-20
1813
-
HI P
R25
627
629
1-
288
310
327
-32
735
237
2-
373
401
423
-41
945
147
6-
463
498
526
-
LO P
R99
105
115
-10
411
112
1-
108
115
126
-11
412
113
2-
119
127
139
-12
313
114
3-
5600
MBh
210.
721
8.4
239.
3-
205.
821
3.4
233.
8-
200.
920
8.3
228.
2-
196.
020
3.2
222.
6-
186.
219
3.0
211.
5-
172.
517
8.8
195.
9-
S/T
0.70
0.58
0.40
-0.
720.
600.
42-
0.74
0.62
0.43
-0.
760.
640.
44-
0.79
0.66
0.46
-0.
800.
670.
46-
∆T24
2116
-24
2116
-24
2116
-25
2116
-24
2116
-23
2015
-
HI P
R24
926
828
3-
279
300
317
-31
734
136
1-
361
389
411
-40
743
846
2-
449
483
510
-
LO P
R96
102
111
-10
110
811
8-
105
112
122
-11
011
812
8-
116
123
134
-12
012
713
9-
75
7875
MBh
239.
224
6.2
266.
528
6.1
233.
624
0.5
260.
327
9.4
228.
023
4.8
254.
127
2.8
222.
522
9.1
247.
926
6.1
211.
421
7.6
235.
525
2.8
195.
820
1.6
218.
223
4.2
S/T
0.86
0.77
0.58
0.37
0.89
0.80
0.60
0.39
0.91
0.82
0.62
0.40
0.94
0.84
0.64
0.41
0.98
0.88
0.66
0.43
0.99
0.88
0.67
0.43
∆T24
2218
1324
2218
1324
2218
1325
2319
1324
2218
1323
2117
12
HI P
R26
228
129
731
029
331
633
334
833
435
937
939
638
040
943
245
142
846
048
650
747
250
853
756
0
LO P
R10
110
711
712
510
611
312
413
211
111
812
913
711
612
413
514
412
213
014
115
112
613
414
615
6
7000
MBh
232.
223
9.1
258.
827
7.7
226.
823
3.5
252.
827
1.3
221.
422
8.0
246.
726
4.8
216.
022
2.4
240.
725
8.4
205.
221
1.3
228.
724
5.4
190.
119
5.7
211.
822
7.4
S/T
0.82
0.73
0.56
0.36
0.85
0.76
0.58
0.37
0.87
0.78
0.59
0.38
0.90
0.81
0.61
0.39
0.93
0.84
0.63
0.41
0.94
0.84
0.64
0.41
∆T25
2319
1325
2319
1325
2319
1326
2419
1325
2319
1324
2218
12
HI P
R25
927
929
430
729
131
333
034
433
035
637
639
237
640
542
844
642
345
648
150
246
850
353
255
4
LO P
R10
010
611
612
310
511
212
213
011
011
712
713
611
512
213
414
212
112
814
014
912
513
314
515
4
5600
MBh
214.
322
0.7
238.
825
6.3
209.
321
5.5
233.
325
0.4
204.
421
0.4
227.
724
4.4
199.
420
5.3
222.
223
8.5
189.
419
5.0
211.
122
6.5
175.
418
0.6
195.
520
9.8
S/T
0.79
0.71
0.54
0.34
0.82
0.73
0.56
0.36
0.84
0.75
0.57
0.37
0.87
0.78
0.59
0.38
0.90
0.81
0.61
0.39
0.91
0.81
0.62
0.40
∆T28
2621
1528
2621
1528
2621
1528
2621
1528
2621
1526
2420
14
HI P
R25
127
028
529
828
230
332
033
432
134
536
438
036
539
341
543
341
144
246
748
745
448
851
653
8
LO P
R97
103
112
120
102
109
119
126
106
113
123
131
112
119
130
138
117
124
136
145
121
129
141
150
IDB:
Ent
erin
g In
door
Dry
Bul
b Te
mpe
ratu
reSh
aded
are
a re
flect
s ACC
A (T
VA) c
ondi
tions
High
and
low
pre
ssur
es a
re m
easu
red
at th
e liq
uid
and
sucti
on a
cces
s fitti
ngs.
Expanded Cooling Data — 20 Tons (Two-speed motor at high speed)
10 www.daikinac.com SS-DCC15 SS-DCC15 www.daikinac.com 11
Expanded Cooling Data — 20 Tons (Two-speed motor at high speed)
Out
door
Am
bien
t Te
mpe
ratu
re
6575
8595
105
115
Ente
ring
Indo
or W
et B
ulb
Tem
pera
ture
IDB
Airf
low
5963
6771
5963
6771
5963
6771
5963
6771
5963
6771
5963
6771
80
7875
MBh
243.
424
8.7
265.
728
4.1
237.
824
2.9
259.
627
7.5
232.
123
7.2
253.
427
0.9
226.
423
1.4
247.
226
4.3
215.
121
9.8
234.
825
1.0
199.
320
3.6
217.
523
2.5
S/T
0.94
0.89
0.72
0.54
1.00
0.92
0.75
0.56
1.00
0.94
0.77
0.57
1.00
1.00
0.79
0.59
1.00
1.00
0.82
0.61
1.00
1.00
0.83
0.62
∆T27
2622
1828
2623
1827
2623
1826
2723
1825
2622
1823
2421
17
HI P
R26
428
430
031
329
631
933
735
133
736
338
340
038
441
343
645
543
246
549
151
247
751
454
256
6
LO P
R10
210
811
812
610
811
412
513
311
211
913
013
811
712
513
614
512
313
114
315
212
713
514
815
7
7000
MBh
236.
324
1.5
258.
027
5.8
230.
823
5.9
252.
026
9.4
225.
323
0.3
246.
026
3.0
219.
822
4.6
240.
025
6.6
208.
821
3.4
228.
024
3.7
193.
519
7.7
211.
222
5.8
S/T
0.90
0.84
0.69
0.51
0.93
0.88
0.71
0.53
0.96
0.90
0.73
0.55
0.99
0.93
0.75
0.56
1.00
0.96
0.78
0.58
1.00
0.97
0.79
0.59
∆T28
2723
1928
2724
1928
2724
1929
2724
1927
2723
1925
2522
17
HI P
R26
228
129
731
029
331
633
434
833
435
937
939
638
040
943
245
142
846
048
650
747
350
953
756
0
LO P
R10
110
711
712
510
611
312
413
211
111
812
913
711
612
413
514
412
213
014
115
112
613
414
615
6
5600
MBh
218.
122
2.9
238.
125
4.6
213.
121
7.7
232.
624
8.6
208.
021
2.5
227.
124
2.7
202.
920
7.3
221.
523
6.8
192.
819
7.0
210.
422
5.0
178.
618
2.5
194.
920
8.4
S/T
0.87
0.81
0.66
0.50
0.90
0.84
0.69
0.51
0.92
0.87
0.70
0.53
0.95
0.89
0.73
0.54
0.99
0.93
0.75
0.56
1.00
0.93
0.76
0.57
∆T31
3026
2131
3026
2132
3026
2132
3026
2131
3026
2129
2824
19
HI P
R25
427
328
830
128
530
632
333
732
434
836
838
436
939
741
943
741
544
647
149
245
849
352
154
3
LO P
R98
104
114
121
103
110
120
128
107
114
125
133
113
120
131
139
118
126
137
146
122
130
142
151
85
7875
MBh
247.
725
2.5
264.
428
2.1
241.
924
6.6
258.
327
5.5
236.
224
0.7
252.
126
9.0
230.
423
4.8
246.
026
2.4
218.
922
3.1
233.
724
9.3
202.
720
6.7
216.
423
0.9
S/T
0.99
0.96
0.86
0.70
1.00
0.99
0.89
0.72
1.00
1.00
0.92
0.74
1.00
1.00
0.95
0.77
1.00
1.00
0.98
0.80
1.00
1.00
0.99
0.80
∆T29
2827
2328
2827
2328
2827
2327
2727
2426
2627
2324
2425
22
HI P
R26
728
730
331
629
932
234
035
534
036
638
740
438
841
744
146
043
646
949
651
748
251
954
857
1
LO P
R10
310
911
912
710
911
612
613
411
312
013
114
011
912
613
814
712
413
214
415
412
913
714
915
9
7000
MBh
240.
524
5.1
256.
727
3.9
234.
923
9.4
250.
726
7.5
229.
323
3.7
244.
826
1.1
223.
722
8.0
238.
825
4.8
212.
521
6.6
226.
924
2.0
196.
820
0.6
210.
122
4.2
S/T
0.94
0.91
0.82
0.67
0.98
0.94
0.85
0.69
1.00
0.97
0.87
0.71
1.00
1.00
0.90
0.73
1.00
1.00
0.94
0.76
1.00
1.00
0.94
0.77
∆T30
2928
2430
3028
2430
3028
2429
3028
2428
2828
2426
2626
23
HI P
R26
428
430
031
329
631
933
735
133
736
338
340
038
441
343
645
543
246
549
151
247
751
454
256
6
LO P
R10
210
811
812
610
811
412
513
311
211
913
013
811
712
513
614
512
313
114
315
212
713
514
815
7
5600
MBh
221.
922
6.2
236.
925
2.8
216.
822
1.0
231.
424
6.9
211.
621
5.7
225.
924
1.0
206.
521
0.5
220.
423
5.1
196.
119
9.9
209.
422
3.4
180.
718
5.2
194.
020
6.9
S/T
0.91
0.88
0.79
0.64
0.94
0.91
0.82
0.67
0.97
0.93
0.84
0.68
1.00
0.96
0.87
0.71
1.00
1.00
0.90
0.73
1.00
1.00
0.91
0.74
∆T33
3331
2734
3331
2734
3331
2734
3331
2732
3331
2730
3029
25
HI P
R25
627
629
130
428
830
932
734
132
735
237
238
837
240
142
344
141
945
147
649
746
349
852
654
9
LO P
R99
105
115
122
104
111
121
129
108
115
126
134
114
121
132
141
119
127
139
148
123
131
143
153
IDB:
Ent
erin
g In
door
Dry
Bul
b Te
mpe
ratu
reSh
aded
are
a re
flect
s AHR
I (TV
A) co
nditi
ons
High
and
low
pre
ssur
es a
re m
easu
red
at th
e liq
uid
and
sucti
on a
cces
s fitti
ngs.
10 www.daikinac.com SS-DCC15 SS-DCC15 www.daikinac.com 11
Expanded Cooling Data — 25 Tons (Two-speed motor on high speed)
Out
door
Am
bien
t Te
mpe
ratu
re65
7585
9510
511
5En
teri
ng In
door
Wet
Bul
b Te
mpe
ratu
reID
BAi
rflo
w59
6367
7159
6367
7159
6367
7159
6367
7159
6367
7159
6367
71
70
9202
MBh
284.
229
4.5
322.
7-
277.
628
7.7
315.
2-
271.
028
0.8
307.
7-
264.
327
4.0
300.
2-
251.
126
0.3
285.
2-
232.
624
1.1
264.
2-
S/T
0.67
0.56
0.39
-0.
700.
580.
40-
0.72
0.60
0.41
-0.
740.
620.
43-
0.77
0.64
0.44
-0.
770.
650.
45-
∆T19
1713
-19
1713
-19
1713
-19
1713
-19
1713
-18
1612
-
kW22
.18
22.6
523
.36
-23
.88
24.3
925
.17
-25
.38
25.9
326
.77
-26
.70
27.2
928
.19
-27
.83
28.4
529
.39
-28
.80
29.4
430
.43
-
HI P
R27
029
030
6-
303
326
344
-34
437
039
1-
392
422
445
-44
147
550
1-
487
524
554
-LO
PR
102
108
118
-10
811
512
5-
112
119
130
-11
812
513
7-
123
131
143
-12
713
614
8-
8200
MBh
275.
928
6.0
313.
3-
269.
527
9.3
306.
0-
263.
127
2.7
298.
7-
256.
726
6.0
291.
5-
243.
825
2.7
276.
9-
225.
923
4.1
256.
5-
S/T
0.64
0.54
0.37
-0.
670.
560.
38-
0.68
0.57
0.39
-0.
700.
590.
41-
0.73
0.61
0.42
-0.
740.
620.
43-
∆T20
1713
-20
1713
-20
1713
-20
1813
-20
1713
-19
1612
-
kW22
.00
22.4
723
.17
-23
.69
24.2
024
.97
-25
.17
25.7
226
.55
-26
.48
27.0
727
.95
-27
.60
28.2
129
.14
-28
.56
29.2
030
.17
-
HI P
R26
728
730
3-
300
322
340
-34
136
738
7-
388
418
441
-43
747
049
6-
482
519
548
-LO
PR
101
107
117
-10
711
312
4-
111
118
129
-11
612
413
5-
122
130
142
-12
613
414
7-
7257
MBh
262.
127
1.7
297.
6-
256.
026
5.3
290.
7-
249.
925
9.0
283.
8-
243.
825
2.7
276.
9-
231.
624
0.1
263.
0-
214.
622
2.4
243.
7-
S/T
0.61
0.51
0.36
-0.
640.
530.
37-
0.65
0.55
0.38
-0.
670.
560.
39-
0.70
0.58
0.40
-0.
710.
590.
41-
∆T20
1813
-21
1814
-21
1814
-21
1814
-21
1813
-19
1713
-
kW21
.66
22.1
122
.80
-23
.31
23.8
024
.56
-24
.76
25.3
026
.12
-26
.05
26.6
227
.49
-27
.14
27.7
428
.65
-28
.08
28.7
129
.66
-
HI P
R26
228
229
7-
294
316
334
-33
435
937
9-
380
409
432
-42
846
048
6-
473
509
537
-LO
PR
9910
511
5-
105
111
121
-10
911
612
6-
114
121
133
-12
012
713
9-
124
132
144
-
75
9202
MBh
289.
029
7.5
322.
134
5.7
282.
329
0.6
314.
633
7.6
275.
628
3.7
307.
132
9.6
268.
827
6.8
299.
632
1.5
255.
426
2.9
284.
630
5.5
236.
624
3.6
263.
628
3.0
S/T
0.76
0.68
0.52
0.3
0.79
0.71
0.54
0.3
0.81
0.73
0.55
0.4
0.84
0.75
0.57
0.4
0.87
0.78
0.59
0.4
0.88
0.79
0.59
0.4
∆T22
2017
1222
2117
1222
2117
1223
2117
1222
2017
1221
1916
10.8
kW22
.36
22.8
323
.55
24.3
24.0
724
.59
25.3
826
.225
.59
26.1
527
.00
27.9
26.9
327
.52
28.4
329
.428
.07
28.6
929
.64
30.6
29.0
529
.70
30.6
931
.7
HI P
R27
229
331
032
2.9
306
329
347
362.
334
837
439
541
2.0
396
426
450
469.
344
547
950
652
8.0
492
530
559
583.
3LO
PR
103
110
120
127.
410
911
612
613
4.6
113
120
131
139.
911
912
613
814
7.0
125
132
145
154.
012
913
715
015
9.3
8200
MBh
280.
628
8.9
312.
733
5.6
274.
128
2.2
305.
432
7.8
267.
527
5.4
298.
132
0.0
261.
026
8.7
290.
931
2.2
248.
025
5.3
276.
329
6.6
229.
723
6.5
256.
027
4.7
S/T
0.73
0.65
0.49
0.3
0.76
0.68
0.51
0.3
0.78
0.69
0.52
0.3
0.80
0.72
0.54
0.3
0.83
0.74
0.56
0.4
0.84
0.75
0.57
0.4
∆T23
2117
1223
2118
1223
2118
1223
2218
1223
2117
1222
2016
11.2
kW22
.18
22.6
523
.36
24.1
23.8
824
.40
25.1
826
.025
.38
25.9
426
.78
27.7
26.7
127
.30
28.1
929
.127
.83
28.4
529
.39
30.4
28.8
029
.45
30.4
331
.5
HI P
R27
029
030
731
9.7
303
326
344
358.
734
437
039
140
8.0
392
422
446
464.
744
147
550
152
2.7
487
524
554
577.
6LO
PR
102
108
118
126.
110
811
512
513
3.3
112
119
130
138.
511
812
513
714
5.5
123
131
143
152.
512
813
614
815
7.7
7257
MBh
266.
527
4.4
297.
131
8.8
260.
326
8.1
290.
131
1.4
254.
126
1.7
283.
230
4.0
248.
025
5.3
276.
329
6.6
235.
624
2.5
262.
528
1.7
218.
222
4.7
243.
226
1.0
S/T
0.70
0.63
0.47
0.3
0.72
0.65
0.49
0.3
0.74
0.66
0.50
0.3
0.77
0.69
0.52
0.3
0.80
0.71
0.54
0.3
0.80
0.72
0.54
0.3
∆T24
2218
1224
2218
1224
2218
1224
2218
1324
2218
1222
2017
11.6
kW21
.83
22.2
922
.99
23.7
23.5
024
.00
24.7
725
.624
.97
25.5
126
.34
27.2
26.2
726
.84
27.7
228
.627
.37
27.9
828
.90
29.9
28.3
228
.95
29.9
130
.9
HI P
R26
428
430
031
3.3
297
319
337
351.
533
736
338
339
9.8
384
413
437
455.
443
246
549
151
2.3
478
514
543
566.
0LO
PR
100
106
116
123.
610
611
212
313
0.6
110
117
127
135.
711
512
313
414
2.6
121
129
140
149.
412
513
314
515
4.6
IDB:
Ent
erin
g In
door
Dry
Bul
b Te
mpe
ratu
reSh
aded
are
a re
flect
s AC
CA (T
VA) R
ating
Con
ditio
ns.
kW =
Tot
al s
yste
m p
ower
Hig
h an
d lo
w p
ress
ures
are
mea
sure
d at
the
liqui
d an
d su
ction
acc
ess
fitting
s.Am
ps: U
nit a
mps
(com
p.+
evap
orat
or +
con
dens
er fa
n m
otor
s)
Des
ign
Subc
oolin
g, 1
6 - 1
9 °F
@ th
e liq
uid
acce
ss fi
tting
con
necti
on A
RI 9
5 te
st c
ondi
tions
. Des
ign
Supe
rhea
t 8 -
12°F
@ th
e co
mpr
esso
r suc
tion
acce
ss fi
tting
con
necti
on.
12 www.daikinac.com SS-DCC15 SS-DCC15 www.daikinac.com 13
Expanded Cooling Data — 25 Tons (Two-speed motor on high speed)
Out
door
Am
bien
t Te
mpe
ratu
re65
7585
9510
511
5En
teri
ng In
door
Wet
Bul
b Te
mpe
ratu
reID
BAi
rflo
w59
6367
7159
6367
7159
6367
7159
6367
7159
6367
7159
6367
71
80
9202
MBh
294.
130
0.6
321.
134
3.3
287.
329
3.6
313.
633
5.3
280.
428
6.6
306.
232
7.3
273.
627
9.6
298.
731
9.3
259.
926
5.6
283.
830
3.3
240.
824
6.0
262.
928
1.0
S/T
0.84
0.79
0.64
0.5
0.87
0.82
0.66
0.5
0.89
0.84
0.68
0.5
0.92
0.86
0.70
0.5
0.96
0.90
0.73
0.5
0.96
0.90
0.74
0.5
∆T25
2421
1625
2421
1725
2421
1725
2421
1725
2421
1723
2219
15.4
kW22
.54
23.0
123
.74
24.5
24.2
724
.79
25.5
926
.425
.80
26.3
727
.23
28.1
27.1
527
.75
28.6
729
.628
.30
28.9
329
.89
30.9
29.2
929
.95
30.9
532
.0
HI P
R27
529
631
332
6.1
309
332
351
366.
035
137
839
941
6.2
400
430
455
474.
045
048
451
153
3.3
497
535
565
589.
2LO
PR
104
111
121
128.
711
011
712
813
6.0
114
122
133
141.
312
012
813
914
8.4
126
134
146
155.
613
013
815
116
0.9
8200
MBh
285.
629
1.8
311.
833
3.3
278.
928
5.0
304.
532
5.5
272.
327
8.2
297.
331
7.8
265.
627
1.4
290.
031
0.0
252.
425
7.9
275.
529
4.5
233.
823
8.9
255.
227
2.8
S/T
0.80
0.75
0.61
0.5
0.83
0.78
0.63
0.5
0.85
0.80
0.65
0.5
0.88
0.82
0.67
0.5
0.91
0.85
0.70
0.5
0.92
0.86
0.70
0.5
∆T26
2521
1726
2522
1726
2522
1726
2522
1726
2521
1724
2320
16.0
kW22
.36
22.8
323
.55
24.3
24.0
824
.59
25.3
826
.225
.59
26.1
527
.00
27.9
26.9
327
.53
28.4
329
.428
.07
28.6
929
.64
30.6
29.0
529
.70
30.6
931
.7
HI P
R27
229
331
032
2.9
306
329
347
362.
334
837
439
541
2.1
396
426
450
469.
444
647
950
652
8.0
492
530
559
583.
4LO
PR
103
110
120
127.
410
911
612
613
4.6
113
120
131
139.
911
912
613
814
7.0
125
132
145
154.
012
913
715
015
9.3
7257
MBh
271.
327
7.2
296.
231
6.6
265.
027
0.8
289.
330
9.2
258.
726
4.3
282.
430
1.9
252.
425
7.9
275.
529
4.5
239.
724
5.0
261.
727
9.8
222.
122
6.9
242.
425
9.2
S/T
0.77
0.72
0.59
0.4
0.79
0.74
0.61
0.5
0.81
0.76
0.62
0.5
0.84
0.79
0.64
0.5
0.87
0.82
0.67
0.5
0.88
0.83
0.67
0.5
∆T26
2522
1827
2622
1827
2622
1827
2622
1827
2522
1825
2421
16.5
kW22
.00
22.4
723
.17
23.9
23.6
924
.20
24.9
725
.825
.17
25.7
226
.55
27.4
26.4
827
.07
27.9
528
.927
.60
28.2
129
.14
30.1
28.5
629
.20
30.1
731
.2
HI P
R26
728
730
331
6.5
300
322
340
355.
134
136
738
740
3.8
388
418
441
460.
043
747
049
651
7.5
482
519
548
571.
7LO
PR
101
107
117
124.
910
711
312
413
1.9
111
118
129
137.
111
612
413
514
4.0
122
130
142
150.
912
613
414
715
6.1
85
9202
MBh
299.
330
5.1
319.
534
0.9
292.
329
8.0
312.
133
2.9
285.
329
0.9
304.
632
5.0
278.
428
3.8
297.
231
7.1
264.
526
9.6
282.
330
1.2
245.
024
9.7
261.
527
9.0
S/T
0.88
0.85
0.77
0.6
0.91
0.88
0.79
0.6
0.93
0.90
0.81
0.7
0.96
0.93
0.84
0.7
1.00
0.97
0.87
0.7
1.00
0.97
0.88
0.7
∆T26
2624
2127
2625
2127
2625
2127
2625
2226
2625
2124
2423
19.9
kW22
.72
23.2
023
.93
24.7
24.4
725
.00
25.8
026
.626
.01
26.5
827
.45
28.4
27.3
827
.99
28.9
129
.928
.54
29.1
830
.15
31.2
29.5
430
.20
31.2
132
.3
HI P
R27
829
931
632
9.4
312
336
354
369.
635
538
240
342
0.4
404
435
459
478.
845
448
951
653
8.6
502
540
571
595.
1LO
PR
105
112
122
130.
011
111
812
913
7.3
115
123
134
142.
712
112
914
114
9.9
127
135
148
157.
113
114
015
316
2.5
8200
MBh
290.
629
6.2
310.
233
0.9
283.
828
9.3
303.
032
3.2
277.
028
2.4
295.
831
5.5
270.
327
5.5
288.
630
7.8
256.
826
1.7
274.
129
2.4
237.
824
2.5
253.
927
0.9
S/T
0.84
0.81
0.73
0.6
0.87
0.84
0.76
0.6
0.89
0.86
0.78
0.6
0.92
0.89
0.80
0.7
0.96
0.92
0.83
0.7
0.96
0.93
0.84
0.7
∆T27
2725
2228
2726
2228
2726
2228
2726
2227
2726
2226
2524
20.7
kW22
.54
23.0
123
.74
24.5
24.2
724
.79
25.5
926
.425
.80
26.3
727
.23
28.1
27.1
527
.75
28.6
729
.628
.30
28.9
329
.89
30.9
29.2
929
.95
30.9
532
.0
HI P
R27
529
631
332
6.1
309
332
351
366.
035
137
839
941
6.2
400
430
455
474.
045
048
451
153
3.3
497
535
565
589.
2LO
PR
104
111
121
128.
711
011
712
813
6.0
114
122
133
141.
312
012
813
914
8.4
126
134
146
155.
613
013
815
116
0.9
7257
MBh
276.
028
1.4
294.
731
4.4
269.
627
4.8
287.
830
7.1
263.
226
8.3
281.
029
9.8
256.
826
1.7
274.
129
2.4
243.
924
8.6
260.
427
7.8
226.
023
0.3
241.
225
7.4
S/T
0.80
0.78
0.70
0.6
0.83
0.80
0.73
0.6
0.85
0.82
0.74
0.6
0.88
0.85
0.77
0.6
0.91
0.88
0.80
0.6
0.92
0.89
0.80
0.7
∆T28
2826
2328
2826
2328
2826
2329
2827
2328
2826
2326
2625
21.3
kW22
.18
22.6
523
.36
24.1
23.8
824
.39
25.1
726
.025
.38
25.9
326
.77
27.7
26.7
027
.29
28.1
929
.127
.83
28.4
529
.39
30.4
28.8
029
.44
30.4
331
.5
HI P
R27
029
030
631
9.6
303
326
344
358.
634
437
039
140
7.9
392
422
445
464.
644
147
550
152
2.6
487
524
554
577.
5LO
PR
102
108
118
126.
110
811
512
513
3.3
112
119
130
138.
511
812
513
714
5.5
123
131
143
152.
512
713
614
815
7.7
IDB:
Ent
erin
g In
door
Dry
Bul
b Te
mpe
ratu
reSh
aded
are
a re
flect
s AH
RI) R
ating
Con
ditio
ns.
kW =
Tot
al s
yste
m p
ower
Hig
h an
d lo
w p
ress
ures
are
mea
sure
d at
the
liqui
d an
d su
ction
acc
ess
fitting
s.Am
ps: U
nit a
mps
(com
p.+
evap
orat
or +
con
dens
er fa
n m
otor
s)
Des
ign
Subc
oolin
g, 1
6 - 1
9 °F
@ th
e liq
uid
acce
ss fi
tting
con
necti
on A
RI 9
5 te
st c
ondi
tions
. Des
ign
Supe
rhea
t 8 -
12°F
@ th
e co
mpr
esso
r suc
tion
acce
ss fi
tting
con
necti
on.
12 www.daikinac.com SS-DCC15 SS-DCC15 www.daikinac.com 13
Standard Two-Speed Belt Drive at High Speed — Down Shot
ESP (" H₂O)
Turns Open
0 1 2 3 4 5 6
CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP
0.2 --- --- --- --- --- --- --- --- --- --- 7203 2.18 6718 1.840.4 --- --- --- --- --- --- 7306 2.54 6777 2.14 6257 1.80 5711 1.48
0.6 --- --- 7477 2.97 6899 2.51 6323 2.10 5716 1.72 5103 1.39 --- ---
0.8 7112 2.96 6467 2.46 5795 2.01 5101 1.61 --- --- --- --- --- ---
1.0 5983 2.38 5190 1.89 --- --- --- --- --- --- --- --- --- ---1.2 4426 1.71 --- --- --- --- --- --- --- --- --- --- --- ---
Two-Speed High-Static Belt Drive at High Speed — Down Shot
ESP (" H₂O)
Turns Open
0 1 2 3 4 5
CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP
0.8 --- --- --- --- --- --- --- --- --- --- 6580 4.301.0 --- --- --- --- --- --- 6930 5.14 6432 4.53 5908 3.98
1.2 --- --- --- --- 6866 5.52 6382 4.80 5916 4.24 5370 3.68
1.4 --- --- 6779 5.80 6417 5.22 5914 4.52 5307 3.89 --- ---
1.6 6685 6.06 6391 5.52 5954 4.90 5288 4.18 --- --- --- ---
1.8 6248 5.75 5782 5.09 5261 4.50 --- --- --- --- --- ---
2.0 5664 5.31 5111 4.71 --- --- --- --- --- --- --- ---2.2 5053 4.81 --- --- --- --- --- --- --- --- --- ---
Airflow Data — 20 Tons Standard Two-Speed Belt Drive at High Speed — Down Shot
ESP (" H₂O)
Turns Open
0 1 2 3 4 5 6
CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP
0.2 --- --- --- --- --- --- --- --- --- --- --- --- 9664 4.050.4 --- --- --- --- --- --- --- --- 9570 4.08 9197 3.82 8702 3.51
0.6 --- --- --- --- --- --- 9038 3.82 8460 3.46 7949 3.14 --- ---
0.8 --- --- 8171 2.93 7630 3.70 7068 2.79 --- --- --- --- --- ---
1.0 --- --- 7901 2.85 7203 3.42 --- --- --- --- --- --- --- ---1.2 7344 4.35 --- --- --- --- --- --- --- --- --- --- --- ---
Two-Speed High-Static Belt Drive at High Speed — Down Shot
ESP (" H₂O)
Turns Open
0 1 2 3 4 5
CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP
0.8 --- --- --- --- --- --- --- --- 8765 6.05 8225 5.381.0 --- --- --- --- --- --- 8663 6.43 8040 5.67 7385 4.97
1.2 --- --- 8978 7.61 8583 6.90 7978 6.00 7395 5.30 6713 4.60
1.4 8845 7.87 8474 7.26 8021 6.52 7393 5.65 6634 4.86 --- ---
1.6 8356 7.58 7989 6.89 7442 6.13 6610 5.22 --- --- --- ---
1.8 7810 7.18 7227 6.37 6576 5.62 --- --- --- --- --- ---2.0 7080 6.64 6389 5.89 --- --- --- --- --- --- --- ---2.2 6316 6.02 --- --- --- --- --- --- --- --- --- ---
Notes• Airflow table represent dry coil with filters installed; SCFM correction factor for wet coil is 4%. • Any adjustment made to the blower should not cause the motor to draw more than the motor rated RLA. Minimum rated SCFM is 350 per ton.• Unit factory shipped with the sheave set at 2.5 turns open.
Airflow Data — 15 Tons
14 www.daikinac.com SS-DCC15 SS-DCC15 www.daikinac.com 15
Airflow Data — 25 Tons
Standard Two-Speed Belt Drive at High Speed - Down Shot
Turns Open 0 1 2 3 4 5 6
RPM 972 941 910 877 845 813 781
ESP SCFM BHP SCFM BHP SCFM BHP SCFM BHP SCFM BHP SCFM BHP SCFM BHP
0.2 --- --- --- --- --- --- 10,369 5.07 9,748 4.41 9,191 3.82 8,683 3.28
0.4 --- --- 10,802 6.00 10,125 5.30 9,484 4.62 8,905 4.01 8,386 3.46 7,913 2.95
0.6 10,519 6.20 9,821 5.47 9,193 4.81 8,599 4.18 8,062 3.61 7,582 3.10 7,143 2.63
0.8 9,482 5.60 8,839 4.93 8,261 4.32 7,714 3.74 7,220 3.21 6,777 2.74 --- ---
1 8,446 5.01 7,857 4.39 7,329 3.83 6,829 3.30 --- --- --- --- --- ---
1.2 7,409 4.41 6,876 3.85 --- --- --- --- --- --- --- --- --- ---
Two-Speed High Static Belt Drive at High Speed - Down Shot
Turns Open 0 1 2 3 4 5 6
RPM 1254 1208 1163 1124 1085 1046 1007
ESP SCFM BHP SCFM BHP SCFM BHP SCFM BHP SCFM BHP SCFM BHP SCFM BHP
0.6 --- --- --- --- --- --- --- --- --- --- --- --- 11,409 7.12
0.8 --- --- --- --- --- --- --- --- --- --- --- --- 10,302 6.46
1 --- --- --- --- --- --- --- --- --- --- 10,159 6.79 9,195 5.79
1.2 --- --- --- --- --- --- --- --- 9,990 7.11 8,961 6.04 8,087 5.13
1.4 --- --- --- --- --- --- 9,789 7.39 8,686 6.25 7,763 5.29 6,980 4.46
1.6 --- --- --- --- 9,543 7.63 8,357 6.40 7,382 5.39 6,566 4.53 --- ---
1.8 --- --- --- --- 7,957 6.48 6,925 5.41 6,077 4.53 --- --- --- ---
2 --- --- 7,667 6.68 6,370 5.34 --- --- --- --- --- --- --- ---
2.2 7,280 6.78 --- --- --- --- --- --- --- --- --- --- --- ---
Notes• Airflow table represent dry coil with filters installed; SCFM correction factor for wet coil is 4%. • Any adjustment made to the blower should not cause the motor to draw more than the motor rated RLA. Minimum rated SCFM is 350 per ton.• Unit factory shipped with the sheave set at 2.5 turns open.
Airflow Pressure Drop of Downflow Economizer for 15- to 25-Ton Rooftop Units (100% Return Air)
CFM 4,500 5,000 5,500 6,000 6,500 7,000 7,500 8,000 8,500 9,000 9,500 10,000
(In. WG) 0.15 0.18 0.22 0.27 0.32 0.37 0.42 0.48 0.55 0.61 0.69 0.76
14 www.daikinac.com SS-DCC15 SS-DCC15 www.daikinac.com 15
0.00
0.05
0.10
0.15
0.20
0.25
0.30
0.35
0.40
0.45
0.50
0 700600500400300200100
Air Velocity (FPM)
Resi
stan
ce (i
n. w
.g.)
2" Deep
Flanders Pre Pleat M13Air Velocity vs Resistance
(Test Size: 24" x 24" x 2" High Capacity)
High Efficiency MERV 13 Air Filter Option
Crankcase Heater, High Efficiency MERV 13 Air Filter Option
Crankcase Heater Selection TableZP/ZPS… Compressor Diameter Compressor Voltage Crankcase
Heater Watts230V 460V 575V16-31 5.5" 0163R00002S 0163R00031S 0163R00032S 40
39-83 6.58/7.3" 0130L00017S 0130L00018S 0130L00019S 70
103-137 9.14” 0130L00020S 0130L00021S 0130L00022S 90
DC* Tonnage Compressor Voltage Crankcase Heater Watts230V 460V 575V
15-20 Ton** 0130L00017S 0130L00018S 0130L00019S 70
25 Ton 0130L00020S 0130L00021S 0130L00022S 90
*Includes C,G&H models. **If Compressor Diameter is 9.14” then use 25 Ton Crankcase heaters.
Tonnage: Filter Nominal Size: Part Number: Order QTY:
15, 20 20 x 25 x 2 0160L00202 6
25 20 X 20 X 2 0160L00201 8
16 www.daikinac.com SS-DCC15 SS-DCC15 www.daikinac.com 17
Heat Kit Electrical Data (Blower Only, Heat Mode)
DCC180***(3V) @ 208 / 240V – 15 Tons
Model RecommendedAirflow Range
EHK3-31 5250 - 6750 CFM
EHK3-46 5250 - 6750 CFM
EHK3-60 5250 - 6750 CFM
DCC180***(4V) @ 480V – 15 Tons
Model RecommendedAirflow Range
EHK4-31 5250 - 6750 CFM
EHK4-46 5250 - 6750 CFM
EHK4-60 5250 - 6750 CFM
DCC180***(7V) @575V – 15 Tons
Model RecommendedAirflow Range
EHK7-31 5250 - 6750 CFM
EHK7-46 5250 - 6750 CFM
EHK7-60 5250 - 6750 CFM
DCC240***(3V) @ 208 / 240V – 20 Tons
Model RecommendedAirflow Range
EHK3-31 7200 - 8500 CFM
EHK3-46 7200 - 8500 CFM
EHK3-60 7200 - 8500 CFM
EHK3-75 7200 - 8500 CFM
DCC240***(4V) @ 480V – 20 Tons
Model RecommendedAirflow Range
EHK4-31 7200 - 8500 CFM
EHK4-46 7200 - 8500 CFM
EHK4-60 7200 - 8500 CFM
EHK4-75 7200 - 8500 CFM
DCC240***(7V) @575V – 20 Tons
Model RecommendedAirflow Range
EHK7-31 7200 - 8500 CFM
EHK7-46 7200 - 8500 CFM
EHK7-60 7200 - 8500 CFM
EHK7-75 7200 - 8500 CFM
Note: When using electric heat kit, the single-point kit installed in the unit is needed to meet UL requirements.
kW CorreCtion FaCtors
kW Correction Factor (for 208/230V Units)
Supply Voltage 240 230 220 210 208
Correction Factor 1 0.92 0.84 0.77 0.75
kW Correction Factor (for 575V Units)
Supply Voltage 560 550 540
Correction Factor 0.95 0.91 0.88
DCC300***(3V) @ 240 / 240V – 25 Tons
Model Airflow Range
EHK3-31 7200 - 8500 CFM
EHK3-46 7200 - 8500 CFM
EHK3-60 7200 - 8500 CFM
EHK3-75 7200 - 8500 CFM
DCC300***(4V) @ 480V – 25 Tons
Model airflow range
EHK4-31 7200 - 8500 CFM
EHK4-46 7200 - 8500 CFM
EHK4-60 7200 - 8500 CFM
EHK4-75 7200 - 8500 CFM
DCC300***(7V) @ 575V – 25 Tons
Model airflow range
EHK7-31 7200 - 8500 CFM
EHK7-46 7200 - 8500 CFM
EHK7-60 7200 - 8500 CFM
EHK7-75 7200 - 8500 CFM
kW Correction Factor (for 460V Units)
Supply Voltage 460 440 430
Correction Factor 0.92 0.84 0.8
16 www.daikinac.com SS-DCC15 SS-DCC15 www.daikinac.com 17
Electrical Data – 15 Ton
Model Number
Electrical Rating
Compressor Circuit 1
Compressor Circuit 2
Outdoor Fan Motor
Indoor Fan Motor
Optional Electric Heat
Optional Powered
Convienience Outlet
Unit Power Supply
RLA LRA RLA LRA QTY HP FLA Type HP FLA Model KW* FLA FLA MCA MOP
DCC180XXX3W 208/230-3-60 25.0 164.0 25.0 164.0 3 0.33 2.02-speed High
Static Belt Drive
7.50 20.3
- - - - 82.6 / 82.6 100 / 100EHK3-31 21.6 / 28.8 60.0 / 69.3 - 100 / 112 100 / 125EHK3-46 32.4 / 43.2 90.1 / 104 - 138 / 155 150 / 175EHK3-60 43.3 / 57.6 120 / 139 - 175 / 164 175 / 175
- - - 7.2 / 6.5 89.8 / 89.1 110 / 110EHK3-31 21.6 / 28.8 60.0 / 69.3 7.2 / 6.5 109 / 120 110 / 125EHK3-46 32.4 / 43.2 90.1 / 104 7.2 / 6.5 147 / 163 150 / 175EHK3-60 43.3 / 57.6 120 / 139 7.2 / 6.5 184 / 172 200 / 175
DCC180XXX3V 208/230-3-60 25.0 164.0 25.0 164.0 3 0.33 2.02-speed Belt
Drive3.00 9.1
- - - - 71.4 / 71.4 90 / 90EHK3-31 21.6 / 28.8 60.0 / 69.3 - 86.4 / 98.0 90 / 100EHK3-46 32.4 / 43.2 90.1 / 104 - 124 / 141 125 / 150EHK3-60 43.3 / 57.6 120 / 139 - 161 / 150 175 / 175
- - - 7.2 / 6.5 78.6 / 77.9 100 / 100EHK3-31 21.6 / 28.8 60.0 / 69.3 7.2 / 6.5 95.4 / 106 100 / 110EHK3-46 32.4 / 43.2 90.1 / 104 7.2 / 6.5 133 / 149 150 / 150EHK3-60 43.3 / 57.6 120 / 139 7.2 / 6.5 170 / 158 175 / 175
DCC180XXX4W 460-3-60 12.2 100.0 12.2 100.0 3 0.33 0.92-speed High
Static Belt Drive
7.50 9.5
- - - - 39.5 50EHK4-31 28.8 34.6 - 55.2 60EHK4-46 43.2 52.0 - 76.8 80EHK4-60 57.6 69.3 - 81.2 90
- - - 3.3 42.8 50EHK4-31 28.8 34.6 3.3 59.3 60EHK4-46 43.2 52.0 3.3 81.0 90EHK4-60 57.6 69.3 3.3 85.3 90
DCC180XXX4V 460-3-60 12.2 100.0 12.2 100.0 3 0.33 0.92-speed Belt
Drive3.00 4.3
- - - - 34.3 45EHK4-31 28.8 34.6 - 48.7 50EHK4-46 43.2 52.0 - 70.3 80EHK4-60 57.6 69.3 - 74.7 80
- - - 3.3 37.6 45EHK4-31 28.8 34.6 3.3 52.8 60EHK4-46 43.2 52.0 3.3 74.5 80EHK4-60 57.6 69.3 3.3 78.8 90
DCC180XXX7W 575-3-60 9.0 78.0 9.0 78.0 3 0.33 0.72-speed High
Static Belt Drive
7.50 7.5
- - - - 29.8 35EHK7-31 28.8 28.9 - 45.5 50EHK7-46 43.2 43.4 - 63.6 70EHK7-60 57.6 57.8 - 67.2 80
- - - 2.6 32.4 40EHK7-31 28.8 28.9 2.6 48.8 50EHK7-46 43.2 43.4 2.6 66.8 70EHK7-60 57.6 57.8 2.6 70.5 80
DCC180XXX7V 575-3-60 9.0 78.0 9.0 78.0 3 0.33 0.72-speed Belt
Drive3.00 3.5
- - - - 25.8 30EHK7-31 28.8 28.9 - 40.5 45EHK7-46 43.2 43.4 - 58.6 60EHK7-60 57.6 57.8 - 62.2 70
- - - 2.6 28.4 35EHK7-31 28.8 28.9 2.6 43.8 45EHK7-46 43.2 43.4 2.6 61.8 70EHK7-60 57.6 57.8 2.6 65.5 70
* Electric Heater kW rating: Rated at 240v for 208-230v units; 480v for 460v units
18 www.daikinac.com SS-DCC15 SS-DCC15 www.daikinac.com 19
* Electric Heater kW rating: Rated at 240v for 208-230v units; 480v for 460v units
Electrical Data – 20 Ton
Model Number
Electrical Rating
Compressor Circuit 1
Compressor Circuit 2
Outdoor Fan Motor
Indoor Fan Motor
Optional Electric Heat
Optional Powered
Convienience Outlet
Unit Power Supply
RLA LRA RLA LRA QTY HP FLA Type HP FLA Model KW* FLA FLA MCA MOP
DCC240XXX3W 208/230-3-60 34.0 240.0 34.0 240.0 3 0.33 2.02-speed High
Static Belt Drive
7.50 20.3
- - - - 103 / 103 125 / 125EHK3-31 21.6 / 28.8 60.0 / 69.3 - 103 / 112 125 / 125EHK3-46 32.4 / 43.2 90.1 / 104 - 138 / 155 150 / 175EHK3-60 43.3 / 57.6 120 / 139 - 175 / 164 175 / 175EHK3-75 54.1 / 72.0 150 / 173 - 175 / 199 200 / 225
- - - 7.2 / 6.5 110 / 109 125 / 125EHK3-31 21.6 / 28.8 60.0 / 69.3 7.2 / 6.5 110 / 120 125 / 125EHK3-46 32.4 / 43.2 90.1 / 104 7.2 / 6.5 147 / 163 150 / 175EHK3-60 43.3 / 57.6 120 / 139 7.2 / 6.5 184 / 172 200 / 175EHK3-75 54.1 / 72.0 150 / 173 7.2 / 6.5 184 / 207 200 / 225
DCC240XXX3V 208/230-3-60 34.0 240.0 34.0 240.0 3 0.33 2.02-speed Belt
Drive5.00 14.0
- - - - 96.4 / 96.4 125 / 125EHK3-31 21.6 / 28.8 60.0 / 69.3 - 96.4 / 104 125 / 125EHK3-46 32.4 / 43.2 90.1 / 104 - 130 / 147 150 / 150EHK3-60 43.3 / 57.6 120 / 139 - 168 / 156 175 / 175EHK3-75 54.1 / 72.0 150 / 173 - 168 / 191 200 / 225
- - - 7.2 / 6.5 104 / 103 125 / 125EHK3-31 21.6 / 28.8 60.0 / 69.3 7.2 / 6.5 104 / 112 125 / 125EHK3-46 32.4 / 43.2 90.1 / 104 7.2 / 6.5 139 / 156 150 / 175EHK3-60 43.3 / 57.6 120 / 139 7.2 / 6.5 177 / 164 200 / 175EHK3-75 54.1 / 72.0 150 / 173 7.2 / 6.5 177 / 199 200 / 225
DCC240XXX4W 460-3-60 16.0 140.0 16.0 140.0 3 0.33 0.92-speed High
Static Belt Drive
7.50 9.5
- - - - 48.1 60EHK4-31 28.8 34.6 - 55.2 60EHK4-46 43.2 52.0 - 76.8 80EHK4-60 57.6 69.3 - 81.2 90EHK4-75 72.0 86.6 - 98.5 110
- - - 3.3 51.4 60EHK4-31 28.8 34.6 3.3 59.3 60EHK4-46 43.2 52.0 3.3 81.0 90EHK4-60 57.6 69.3 3.3 85.3 90EHK4-75 72.0 86.6 3.3 103 110
DCC240XXX4V 460-3-60 16.0 140.0 16.0 140.0 3 0.33 0.92-speed Belt
Drive5.00 6.6
- - - - 45.2 60EHK4-31 28.8 34.6 - 51.6 60EHK4-46 43.2 52.0 - 73.2 80EHK4-60 57.6 69.3 - 77.5 90EHK4-75 72.0 86.6 - 94.9 110
- - - 3.3 48.5 60EHK4-31 28.8 34.6 3.3 55.7 60EHK4-46 43.2 52.0 3.3 77.3 80EHK4-60 57.6 69.3 3.3 81.7 90EHK4-75 72.0 86.6 3.3 99.0 110
DCC240XXX7W 575-3-60 12.9 107.6 12.9 107.6 3 0.33 0.72-speed High
Static Belt Drive
7.50 7.5
- - - - 38.7 50EHK7-31 28.8 28.9 - 45.5 50EHK7-46 43.2 43.4 - 63.6 70EHK7-60 57.6 57.8 - 67.2 80EHK7-75 72.0 72.3 - 81.7 90
- - - 2.6 41.3 50EHK7-31 28.8 28.9 2.6 48.8 50EHK7-46 43.2 43.4 2.6 66.8 70EHK7-60 57.6 57.8 2.6 70.5 80EHK7-75 72.0 72.3 2.6 84.9 100
DCC240XXX7V 575-3-60 12.9 107.6 12.9 107.6 3 0.33 0.72-speed Belt
Drive5.00 5.2
- - - - 36.4 45EHK7-31 28.8 28.9 - 42.6 45EHK7-46 43.2 43.4 - 60.7 70EHK7-60 57.6 57.8 - 64.3 70EHK7-75 72.0 72.3 - 78.8 90
- - - 2.6 39.0 50EHK7-31 28.8 28.9 2.6 45.9 50EHK7-46 43.2 43.4 2.6 64.0 70EHK7-60 57.6 57.8 2.6 67.6 80EHK7-75 72.0 72.3 2.6 82.0 90
18 www.daikinac.com SS-DCC15 SS-DCC15 www.daikinac.com 19
* Electric Heater kW rating: Rated at 240v for 208-230v units; 480v for 460v units
Electrical Data – 25 Ton
Model Number
Electrical Rating
Compressor Circuit 1
Compressor Circuit 2
Outdoor Fan Motor
Indoor Fan Motor
Optional Electric Heat
Optional Powered
Convienience Outlet
Unit Power Supply
RLA LRA RLA LRA QTY HP FLA Type HP FLA Model KW* FLA FLA MCA MOP
DCC300XXX3W 208/230-3-60 48.1 245.0 48.1 245.0 2 1.00 4.22-speed High
Static Belt Drive
7.50 21.0
- - - - 138 / 138 175 / 175EHK3-31 21.6 / 28.8 60.0 / 69.3 - 138 / 138 175 / 175EHK3-46 32.4 / 43.2 90.1 / 104 - 139 / 156 175 / 175EHK3-60 43.3 / 57.6 120 / 139 - 176 / 165 200 / 175EHK3-75 54.1 / 72.0 150 / 173 - 176 / 199 200 / 225
- - - 7.2 / 6.5 145 / 144 175 / 175EHK3-31 21.6 / 28.8 60.0 / 69.3 7.2 / 6.5 145 / 144 175 / 175EHK3-46 32.4 / 43.2 90.1 / 104 7.2 / 6.5 148 / 164 175 / 175EHK3-60 43.3 / 57.6 120 / 139 7.2 / 6.5 185 / 173 200 / 175EHK3-75 54.1 / 72.0 150 / 173 7.2 / 6.5 185 / 208 200 / 225
DCC300XXX3V 208/230-3-60 48.1 245.0 48.1 245.0 2 1.00 4.22-speed Belt
Drive7.50 21.0
- - - - 138 / 138 175 / 175EHK3-31 21.6 / 28.8 60.0 / 69.3 - 138 / 138 175 / 175EHK3-46 32.4 / 43.2 90.1 / 104 - 139 / 156 175 / 175EHK3-60 43.3 / 57.6 120 / 139 - 176 / 165 200 / 175EHK3-75 54.1 / 72.0 150 / 173 - 176 / 199 200 / 225
- - - 7.2 / 6.5 145 / 144 175 / 175EHK3-31 21.6 / 28.8 60.0 / 69.3 7.2 / 6.5 145 / 144 175 / 175EHK3-46 32.4 / 43.2 90.1 / 104 7.2 / 6.5 148 / 164 175 / 175EHK3-60 43.3 / 57.6 120 / 139 7.2 / 6.5 185 / 173 200 / 175EHK3-75 54.1 / 72.0 150 / 173 7.2 / 6.5 185 / 208 200 / 225
DCC300XXX4W 460-3-60 18.6 125.0 18.6 125.0 2 1.00 2.12-speed High
Static Belt Drive
7.50 10.1
- - - - 56.1 70EHK4-31 28.8 34.6 - 56.1 70EHK4-46 43.2 52.0 - 77.6 80EHK4-60 57.6 69.3 - 81.9 90EHK4-75 72.0 86.6 - 99.2 110
- - - 3.3 59.4 70EHK4-31 28.8 34.6 3.3 60.1 70EHK4-46 43.2 52.0 3.3 81.7 90EHK4-60 57.6 69.3 3.3 86.0 90EHK4-75 72.0 86.6 3.3 103 110
DCC300XXX4V 460-3-60 18.6 125.0 18.6 125.0 2 1.00 2.12-speed Belt
Drive7.50 10.1
- - - - 56.1 70EHK4-31 28.8 34.6 - 56.1 70EHK4-46 43.2 52.0 - 77.6 80EHK4-60 57.6 69.3 - 81.9 90EHK4-75 72.0 86.6 - 99.2 110
- - - 3.3 59.4 70EHK4-31 28.8 34.6 3.3 60.1 70EHK4-46 43.2 52.0 3.3 81.7 90EHK4-60 57.6 69.3 3.3 86.0 90EHK4-75 72.0 86.6 3.3 103 110
DCC300XXX7W 575-3-60 14.7 100.0 14.7 100.0 2 1.00 1.62-speed High
Static Belt Drive
7.50 8.2
- - - - 44.6 50EHK7-31 28.8 28.9 - 46.4 50EHK7-46 43.2 43.4 - 64.5 70EHK7-60 57.6 57.8 - 68.1 80EHK7-75 72.0 72.3 - 82.5 100
- - - 2.6 47.2 60EHK7-31 28.8 28.9 2.6 49.6 60EHK7-46 43.2 43.4 2.6 67.7 70EHK7-60 57.6 57.8 2.6 71.3 80EHK7-75 72.0 72.3 2.6 85.8 100
DCC300XXX7V 575-3-60 14.7 100.0 14.7 100.0 2 1.00 1.62-speed Belt
Drive7.50 8.2
- - - - 44.6 50EHK7-31 28.8 28.9 - 46.4 50EHK7-46 43.2 43.4 - 64.5 70EHK7-60 57.6 57.8 - 68.1 80EHK7-75 72.0 72.3 - 82.5 100
- - - 2.6 47.2 60EHK7-31 28.8 28.9 2.6 49.6 60EHK7-46 43.2 43.4 2.6 67.7 70EHK7-60 57.6 57.8 2.6 71.3 80EHK7-75 72.0 72.3 2.6 85.8 100
20 www.daikinac.com SS-DCC15 SS-DCC15 www.daikinac.com 21
35.5
51
7.01
750.7
50
88.1
1612
.137
8.20
4
3.05
8
133.
354
18.5
79
8.94
9
DC
*180
/240
***
15 A
ND
20
TON
CO
ME
RC
IAL
ALL
DIM
EN
SIO
NS
AR
E G
IVE
N IN
INC
HE
SA
LL D
IME
NS
ION
S A
ND
SP
EC
IFIC
ATI
ON
S A
RE
SU
BJE
CT
TO C
HA
NG
E W
ITH
OU
T N
OTI
FIC
ATI
ON
BA
CK
VIE
W
CO
ND
EN
SA
TED
RA
IN O
UTL
ET
THIS
SID
E O
NLY
FOR
K H
OLE
SB
OTH
SID
ES
AN
DC
ON
DE
NS
ER
EN
D
LIFT
SH
AC
KLE
HO
LES
BO
TH S
IDE
S A
ND
EN
DS
LEFT
EN
D V
IEW
TSTA
T W
IRE
E
NTR
AN
CE
LIN
E W
IRE
EN
TRA
NC
E
DIS
CO
NN
EC
T S
WIT
CH
LOC
ATI
ON
TOP
VIE
W
(if a
pplic
able
)
Dimensions — 15 & 20 Tons
20 www.daikinac.com SS-DCC15 SS-DCC15 www.daikinac.com 21
8.20
4
3.05
8
12.1
25
88.1
16
7.01
7
50.7
50
35.5
51
133.
354
53.2
12
TOP
VIE
W BA
CK
VIE
W
LEFT
EN
D V
IEW
DC
*300
***
25-T
ON
C
OM
ME
RC
IAL
ALL
DIM
EN
SIO
N G
IVE
N A
RE
IN IN
CH
ES
ALL
DIM
EN
SIO
NS
AN
D S
PE
CIF
ICA
TIO
NS
AR
E S
UB
JEC
T TO
CH
AN
GE
WIT
HO
UT
NO
TIC
E.
CO
ND
EN
SA
TED
RA
N O
UTL
ET
THIS
SID
E O
NLY
FOR
K H
OLE
SB
OTH
SID
ES
AN
DC
ON
DE
NS
ER
EN
D
LEFT
SH
AC
KLE
HO
LES
BO
TH S
IDE
S A
ND
EN
DS
TSTA
T W
IRE
EN
TRA
NC
E
LIN
E W
IRE
EN
TRA
NC
E
Dimensions — 25 Tons
22 www.daikinac.com SS-DCC15 SS-DCC15 www.daikinac.com 23
Electrical Entrance Locations
Unit Clearances
Maintain an adequate clearance around the unit for safety, service, maintenance, and proper unit operation. Leave a total clearance of 75” on the main control panel side of the unit for possible removal of fan shaft, coil, electric heat, and gas furnace. Leave a clearance of 48” on all other sides of the unit for possible compressor removal or service access, and to ensure proper ventilation and condenser airflow. Do not install the unit beneath any obstruction. Install the unit away from all building exhausts to inhibit Ingestion of exhaust air into the unit’s fresh-air intake.
12¹/₈”
3³/₅”
Low-Voltage Entrance3⁴/₅”
High-Voltage Entrance
Vertical Discharge (Top of Unit)
48”22”
7”
2 x 21” 2 x 60”
Return
Supply22”
46¹⁄₁₀”
9⅔”
Flue Vent
Gas Inlet Location (¾” NPT)
75"
48"
48"
6" 36" MINIMUMROOF OVERHANG
36" MINIMUM ROOF OVERHANG
22 www.daikinac.com SS-DCC15 SS-DCC15 www.daikinac.com 23
Roof Curb Installation — Rigging
Provisions for forks have been included in the unit base frame. No other fork locations are approved.
• Unit must be lifted by the four lifting holes lo-cated at the base frame corners.
• Lifting cables should be attached to the unit with shackles.• The distance between the crane hook and the top of the unit must
not be less than 60”.• Two spreader bars must span over the unit to prevent dam-
age to the cabinet by the lift cables. Spreader bars must be of sufficient length so that cables do not come in contact with the unit during transport. Remove wood struts mounted beneath unit base frame before setting unit on roof curb. These struts are intended to protect unit base frame from fork lift damage. To remove the struts, extract the sheet metal retainers and pull the struts through the base of the unit. Refer to rigging label on the unit.
Important: If using bottom discharge with roof curb, duct-work should be attached to the curb prior to installing the unit. Duct-work dimensions are shown in Roof Curb Installation Instructions Manual.Refer to the Roof Curb Installation Instructions for proper curb installation. Curbing must be installed in compliance with the National Roofing Contractors Association Manual.Lower unit carefully onto roof mounting curb. While rigging the unit, the center of gravity will cause the condenser end to be lower than the supply air end.Bring condenser end of unit into alignment with the curb. With condenser end of the unit resting on curb member and using curb as a fulcrum, lower opposite end of the unit until entire unit is seated on the curb. When a rectangular cantilever curb is used, take care to center the unit. Check for proper alignment and orientation of supply and return openings with duct. To assist in determining rigging requirements, unit weights are shown below.
15-Ton Units Weights (bls.) 20-Ton Units Weights
(lbs.) 25-Ton Units Weights (lbs.)
Weight A 590 Weight A 644 Weight A 626
Weight B 482 Weight B 525 Weight B 464
Weight C 492 Weight C 504 Weight C 501
Weight D 401 Weight D 412 Weight D 518
Shipping Weight 2080 Shipping Weight 2202 Shipping Weight 2377
Operating Weight 1965 Operating Weight 2085 Operating Weight 2109
Note: These weights are calculated without installed accessories.
Corner & Center-of-Gravity Locations
COMPRESSOR 1
COMPRESSOR 2
CG
EVAP
OR
ATO
RC
OIL
S
A
B
C
X D
Y40”Compressor 1
Re
tuR
n
eva
po
Ra
toR C
oil
Su
pp
ly
Compressor 2
60"
24 www.daikinac.com SS-DCC15 SS-DCC15 www.daikinac.com 25
Roof Curb Installation
Curb installations must comply with local codes and should follow the established guidelines of the National Roofing Contractors Association.Proper unit installation requires that the roof curb be firmly and permanently attached to the roof structure. Check for adequate fastening method prior to setting the unit on the curb.Full perimeter roof curbs are available from the factory and are shipped unassembled. The installing contractor is responsible for field assembly, squaring, leveling, and mounting on the roof structure. All required hardware necessary for the assembly of the sheet metal curb is included in the curb accessory package.
• Determine sufficient structural support before locating and mounting the curb and package unit.• Duct-work must be constructed using industry guidelines. The duct-work must be placed into the
roof curb before mounting the package unit. Our full perimeter curbs include duct connection frames to be assembled with the curb. Cantilevered-type curbs are not available from the factory.
• Contractor furnishes curb insulation, cant strips, flashing, and general roofing material.• Support curbs on parallel sides with roof members. To prevent damage to the unit,
the roof members cannot penetrate supply and return duct openings.Note: The unit and curb accessories are designed to allow vertical duct installation before unit placement. Duct installation after unit placement is not recommended.See the manual shipped with the roof curb for assembly and installation instructions.
123 Curb Top O.D.
119¾ Curb Top O.D.
74¾ Curb O.D.
78 Curb Top O.D.
61⅞ 61⅞
Insulated Panels 11¼
1⅝ Typ.
17²/₂₅ 17²/₂₅ 17²/₂₅
1¾
123 Curb Bottom O.D.1⅜ Typ. 77½ Curb Bottom O.D.
1¾
23⅞
24 www.daikinac.com SS-DCC15 SS-DCC15 www.daikinac.com 25
Wiring Diagram — DCC 15 & 20 Tons (230V/460V/575V, Two-Speed Belt Drive)
CM3
CM1
CM2
FC2
FC3
TB2
F
C
F
C
F
GRND
CM3
CM1
CM2
FC1
FC2
FC3
TB2
F
F
C
F
C
GRND
RD
BK
BK
BK
PU
PU
PU
PU
PU
PU
PU
PU
BR BR
BR
BR
BR
BR
BR
BR
RD
RD
GR
BK
BK
PB
0140L03208-A
322222224
1
23
22 2222241
2
BL
BL
YL
CCR2
CCR1
POWER SUPPLYSEE NOTE 4
208V-240V-460V-575V 3 ph - 60Hz
LOWSPEED
CB2
L2
T3
L1
T2
L3
T1
HIGHSPEED
CB1
L2
T3
L1
T2
L3
T1
YL
BL
GY
BK
RD
OR
L3T3
L2
CC1L1T1
T2
L3T3
L2
CC2L1T1
T2
L3T3
L2
BC1L1T1
T2
L3T3
L2
BC2L1T1
T2
T3
T2
T1
COMP
1RD
YL
BK
CCH1
T3
T2
T1
COMP
2RD
YL
BK
CCH2
C
TR
24V
208 460240 575
4 2
16
CCHR2
4 2
CCHR1
4 2
16
4 2
YLBL
YLBL
GRPU
NONC 41
2
35 NONC 4
12
35
BR2
BR1GR
GR
GRYL
BL
WH
PU
GR
GR
BL
GR
BLBL
BL
BL
PK
PK
ORRD
RD
BK
BK
BK
RDRD
BK
RDOR
OR
OR
OR
OR
OR
OR
BK
RD
RD
RD
BK
BK
BK
BK
BK
BK
BK
BK
RD
RD
YL
96
3
85
2
74
1WH
YL
BL
BL
RD
BKOR
PK
TO THERMOSTAT
RD
RD
K1
K1
BL
WH
BR
RD
BL
XFMR-C
BR
R
BL
NC
EBTDR
BR
GR
BL GR
PU
BL
GR
BLM2
BR
WH
RD
C
COM
R
REPLACE JUMPER W
ITHSM
OKE/FIRE DETECTOR
C Y1 Y2S2 G
WH
SEE NOTE 4
S1
RD
W1 W2 OTB1
XFMR-R
SPEED UP
NOTE
BR
RD
PU
GR
G
RD
#2
M1
RD
PU
NO
GR
PK
YL
PU
YL
YL
RD
1
4
7
2
5
8
3
6
9
BRPU
PU
PU
PU
YLWH
WH
PU
PUYL
OR
RD
RD
PU
OR
RDBK
GY
BL
YL
HIGHEM
LOW
YL
YLYL
BKBK
BK
12
1311
2
3
1
SEE NOTE 5
1 32
YL
HPS2LPS2
YL
HPS1LPS1
BL
BL
WH
ORRDBK
SEE NOTE 3PLF 2
PLF 1
YLYL
PUPU
BLBL
Wiri
ng is
sub
ject
to c
hang
e. A
lway
s re
fer
to t
he w
iring
dia
gram
on
the
unit
for t
he m
ost u
p-to
-dat
e w
iring
.⚠
War
ning
High
Vol
tage
: Dis
conn
ect
all p
ower
bef
ore
serv
icin
g or
inst
allin
g th
is u
nit.
Mul
tiple
pow
er
sour
ces m
ay b
e pr
esen
t. F
ailu
re to
do
so m
ay ca
use
prop
erty
dam
age,
per
sona
l inju
ry, o
r dea
th.⚡
26 www.daikinac.com SS-DCC15 SS-DCC15 www.daikinac.com 27
Wiring Diagram — DCC 15 & 20 Tons (230V/460V/575V, Two-Speed Belt Drive cont.)
0140L02915-A
CC2
CF2
EBTDR
CC1
L2
T3
COMP1
T2
G
1
F
R
CM2
L1
CC1T1
6
BC
CC
CM
CMR
COMP
ECON
EBTD
EMR
R
EM
FC
GND
HPS
LPS
PB
PLF
TB1
TR
C
C
24V
PLF2
CC1
T3
L3
CONDENSER MOTOR
CONDENSER MOTOR RELAY
COMPRESSOR
ECONOMIZER
EQUPIMENT GROUND
NOTES:
1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY.2. USE COPPER CONDUCTORS ONLY ++ USE N.E.C. CLASS 2 WIRE3. ECONOMIZER PLUG LOCATED IN THE RETURN AIR COMPARTMENT, REMOVE MALE PLUG, ATTACH FEMALE PLUG TO THE ECONOMIZER ACCESSORY.4. FOR TWO STAGE OPERATION REMOVE W1 TO W2 WIRE JUMPER.5. FOR 208V OPERATION MOVE BLACK WIRE FROM TERMINAL 3 TO TERMINAL 2 ON 240V TRANSFORMER
TR
4
5
208-240V
208-240/460/575/3/60
T2
PLF1
3
EBTDR
R
EBTDR
LPS2
HPS2
CF3
CC2
T3
T1
COMP2
T2
F CM3
CC2T1
C
CC2T3
T2
CC1
LPS1
HPS1
5
69
7 4
3
28
1
THERMOSTAT ++
THERMOSTAT
RD
W1
STAT
Y1
Y2
WH
C
G
YL
Y2
R
C
G
R
W1
TB1
PK
GR
Y1
BL
OO OR
9
7
8
W2W2 BR
++
CF1
F CM1
C
T1
TB2
CCH
CCHR
2 1
2 1
CCH1
CCH2
CCHR1
CCHR2
6
6 4
4
CCR
24
24
CCR1
CCR2
SEENOTE 3
SEE UNIT RATING PLATE FOR TYPE AND SIZE OF OVER CURRENT PROTECTION
WIRE CODE
BK BLACK
BL BLUE
BR BROWN
GR GREEN
OR ORANGE
PK PINK
PU PURPLE
RD RED
WH WHITE
YL YELLOW
YL/PK YELLOW WITH PINK STRIP
BL/PK BLUE WITH PINK STRIP
FACTORY WIRING
LOW VOLTAGE
LINE VOLTAGE
FIELD WIRING
2 STAGE COOLING
OPTIONALHIGH VOLTAGE
FIELD WIRING
HIGH VOLATGE
LOW VOLATGE
COMPONENT LEGEND
BLOWER CONTACTOR
COMPRESSOR CONTACTOR
CRANK CASE HEATER
CRANK CASE HEATER RELAY
COMPRESSOR CONTACTOR RELAY
ELECTRONIC BLOWER TIME DELAY
EVAPORATOR MOTOR RELAY
RELAY
EVAPORATOR MOTOR
FAN CAPACITOR
LOW PRESSURE SWITCH
HIGH PRESSURE SWITCH
POWER DISTRUBTION BLOCK
FEMALE PLUG / CONNECTOR
TERMINAL BLOCK (24V SIGNAL)
TERMINAL BLOCK (L1)
TRANSFORMER
SUPPLY VOLTAGE
2
NOTE 5
31
31
R
REPLACE JUMPER W
ITHSM
OKE/FIRE DETECTOR
C Y1 Y2S2 G
WH
SEE NOTE 4
S1
RD
W1 W2 OTB1
BLOWER RELAYBR
EM
HIGH SPEED
LOW SPEED BC2CB2
CB1BC1
CB2BC2
BC2CB2
BC1CB1
BC1CB1
CCHR1
CCHR2
BC1
BC2
2
5
4
BR1
BR1
2
5
4
BR2
BR2
1 3
1 3
Wiri
ng is
sub
ject
to c
hang
e. A
lway
s re
fer
to t
he w
iring
dia
gram
on
the
unit
for t
he m
ost u
p-to
-dat
e w
iring
.⚠
War
ning
High
Vol
tage
: Dis
conn
ect
all p
ower
bef
ore
serv
icin
g or
inst
allin
g th
is u
nit.
Mul
tiple
pow
er
sour
ces m
ay b
e pr
esen
t. F
ailu
re to
do
so m
ay ca
use
prop
erty
dam
age,
per
sona
l inju
ry, o
r dea
th.⚡
26 www.daikinac.com SS-DCC15 SS-DCC15 www.daikinac.com 27
Wiring Diagram — DCC 25 Tons (230V/460V/575V, Two-Speed Belt Drive - Controls Diagram)
0140L04764-A
3A
1 3
42CC1
CMC1
CC2
CMC2
1234
12
1234
12
AUX2-IOCCE-GND
EXH1AUX1-O
Y2-IY2-OY1-I
CR
Y1-O
12
MATMAT
12
OATOAT
12
S-BUSS-BUS
123
1234
IAQ 2-10IAQ COMIAQ 24V
ACT COMACT 24V
GRDLUG
MAS
OD ENTH
ECONACT
ECON PLMECON MODULE
ECON PLF
ECON SHRTPLM
PLM 3
PLF 3
CCR1
TB3
PU
BL
BL
PU
YL
GR
BL
TB3
BL
SUPPLY (LINE) VOLTAGE
24 VAC
TR1
2 2
CONTROLS DIAGRAMDCC300***(3,4,7) V
2SPD EM
3
3GR
EBTDR
(NO)
(NC)COM
G
R
XFMR-R XFMR-C
C
SPEEDUP
M1
M2
7
6
BL
HPS1 LPS1
HPS2 LPS2
PU
YL
PU
YL
PU
YL
PU
5 6
1 3
42
CCR2
5 6
1
2
3
FM1
1
2
1
2
1
2
3
FM2
1
2
1
2
-t°
-t°
1
2
3
1
2
1
2-t°
1 3
42
LAR
5 6
LAM2
T1
T2
LATT6
LA CMC
1
2
3
1
2
1
2
-t°
LAM1
1 3
42
CMR
5 6 BK
BK
BK
BKBL
BL
OR
BK
YL
BK
RD BL
BLWH WH
WH
BL
GY
WH
WH
OR
OR
WH
WHBL
BR
OR
OR
WH
WH
RD
RD
RD
RDBL
BK
BL
BR
123
123
R CS1S2YIY2GW1 W2
TB1
FIELDCONTROL WIRINGCLASS 2
4
1 2 3 4 5 6 7 8 9
HEAT PLF
BRWH
BL
GR RD PU
PU
YL
YL
BK
5
BLRD
RD
BL
YL
BL
RD
YL
BL
BL
YL
YL
PU
PU
BLOR
PU
BL
GR
GR
RD
RD
RD
RD
GY
YL
YL
PU
YL
PU
PU
GR
PU
PU
1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE OF INSULATION AS ORIGINAL (USE COPPER CONDUCTORS ONLY).
2. IF OPTIONAL ECONOMIZER IS INSTALLED, REMOVE ECON SHRT PLM AND CONNECT ECON PLM TO ECON PLF.
3. TB3 LOW VOLTAGE TERMINAL BLOCK.4 TERMINALS FOR 24VAC PWR (RD,BK,BR WIRE) AND 6 TERMINALS FOR 24VAC COM (BL WIRE).
4. CONNECTIONS SHOWN ARE FOR 1-STAGE HEAT OPERATION. WHEN 2-STAGE OPERATION IS REQUIRED REMOVE WH JUMPER WIRE CONNECTING W2 TO W1 ON TB1.
5. IF OPTIONAL SMOKE DETECTOR IS INSTALLED, REMOVE RD JUMPER WIRE CONNECTING S1 TO S2 ON TB1 AND MAKE THE FOLLOWING WIRE CONNECTIONS: RD WIRE TO S1,BR WIRE TO TB3 (24V/PWR),BL WIRE TO TB3 (24V/COM).
NOTES:
BL
BL
BL BR WH PU RD
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
YL
WH RD
1
2
3
4
5
6
7
8
9
RD
BL
RD
GY
BL
YLPU RD
BRWH GR RD RD
6. EBTDR RELAY ENERGIZES 7 SEC AFTER 24VAC IS APPLIED TO "G". THE RELAY DE-ENERGIZES 65 SEC AFTER 24VAC IS REMOVED FROM "G".
7. EBDTR RELAY DELAYS WILL DECREASE TO APPROX 3-5 SEC WHEN "SPEEDUP" IS SHORTED TO "C".
8. IF LOW AMBIENT KIT IS INSTALLED, CONNECT GY WIRE FROM LAM2-3 TO CMR-4. ALSO CONNECT BL COM WIRES FROM LAT-T6 AND LAM2 -2 TO TB3 (24V COM).
RD
OR8BL
GY
RD
BL
BL
8
BL
ECON OPTION
LOW AMBOPTION
BL
PU
PU
BK
RD RD
RD
GY
GYYL
RD
RD
BL
GR
GR GR
PU
ORBKYLRD
BL
BR GR RD RD PU YL
YLPUBRWH GR RD RD RD
BC2LOW SPEED
BC1HIGH SPEED
BL
BL
BR2
BL
YLPU
WH
YL
GR
PU
BL
BL
1 3
42
5 6
BR1
1 3
42
5 6
BK
BK
GR
BL
BR
BR
BL BL
YL
BR BRBKGR
GR
BL
YLYL
YL
BL
GY
BL
OR
WH
WHWH YL
YL
BL
YLOR
BK
PU
BL
BL
BL
YL
BK
BL
BL
BL
BL
BL
BL
WH
WH
WH
BL
WH
WHWH
WH
WH
BL
BK
THERMOSTAT WIRING
Y1
TB1
W
G
W
PK
RD
Y1
R
OR
BL
GR
C
2 STAGE COOLING
WH
OO
Y2
C
G
R
YL
PK
RD
OR
BR
STAT
Y2SEN2
SEN1
7
18
8
17
6
16 B
R
Y
Y
AUX B
AUX A
10
9
B
R
Y
Y
SENSOR 1
SENSOR 2
B
R
Y
Y
B
R
Y
Y
SMOKE DETECTOR
SMK DET OPTION
24V AC/DC
PK
BL 5
PLF PLM
PLF PLM
PLF PLM
PLF PLM
9. LAT ON/OFF TIME SETTINGS : ON -TIME (LEFT COLUMN) : 2,8 = ON OFF -TIME (RIGHT COLUMN) : 8 = ON ALL OTHER DIP SWITCHES = OFF
9W
iring
is s
ubje
ct to
cha
nge.
Alw
ays
refe
r to
the
wiri
ng d
iagr
am o
n th
e un
it fo
r the
mos
t up-
to-d
ate
wiri
ng.
⚠ W
arni
ngHi
gh V
olta
ge: D
isco
nnec
t al
l pow
er b
efor
e se
rvic
ing
or in
stal
ling
this
uni
t. M
ultip
le p
ower
so
urce
s may
be
pres
ent.
Fai
lure
to d
o so
may
caus
e pr
oper
ty d
amag
e, p
erso
nal in
jury
, or d
eath
.⚡
28 www.daikinac.com SS-DCC15 SS-DCC15 www.daikinac.com 29
WIRING DIAGRAMS FOR MODELS WITH DDC CONTROLSFor complete information and installation instructions for models
with DDC controls, see manual DK-DDC-TGD-XXX
28 www.daikinac.com SS-DCC15 SS-DCC15 www.daikinac.com 29
Wiri
ng is
sub
ject
to c
hang
e. A
lway
s re
fer
to t
he w
iring
dia
gram
on
the
unit
for t
he m
ost u
p-to
-dat
e w
iring
.⚠
War
ning
High
Vol
tage
: Dis
conn
ect
all p
ower
bef
ore
serv
icin
g or
inst
allin
g th
is u
nit.
Mul
tiple
pow
er
sour
ces m
ay b
e pr
esen
t. F
ailu
re to
do
so m
ay ca
use
prop
erty
dam
age,
per
sona
l inju
ry, o
r dea
th.⚡
Wiring Diagram with DDC — DCC0180*/ DCC240* 208-230, 460, 575 / 3 / 60 2SP Control
CONTROL WIRING DIAGRAMDCC(180-240)****V
DDC
CC1
CC2
ECON
XS(CLASS2)
BK
DA
BCS
OAT
ESPSCS
TB1 T1
24VAC
CFS
RSS
LDS
CO2
T2
T3
T4
T5
LPS1
HPS2
HPS1
LPS2
BL/PK
BL/PK
YL/PK
YL/PK
PK
BK
BK
GND24 VAC(PWR)
OAHVOUT (DC)
GND24VAC(COM)
24 VAC(PWR)
VOUT (DC)
VOUT (DC)24 VAC(PWR)
IAH
GND
BI8
BI5
121110
1
COM3-8RLY8
BI1 BI2
BI3 BI4
BI7
BR
RDCOM3-8
RLY7RLY6RLY5
RLY4RLY3
COM1
PU
(OAT)
(CFS)
(EMER)(FAN PROV)
(HEAT 2)(HEAT 1)
BI6 (SHED)
RLY1
RLY2COM2
(24V IN)
(ECON PWR)
(EXF)(ALRM)
(ECON DMPR)
(OAH)
(ISOL GND)
(CO2)
23456
78
1
2
3456789
DDC (CLASS2)
(ECON FB)
C(CLASS2)
TB2
DAT
(COMP2 OUT)
(COMP1 OUT)(COMP1 IN)
(COMP2 IN)
YL
YL
4
21
65
3
987
HTR PLF2
WH
BR
65
4321 AO1
AO2 AO3 AO4
GNDGND
AG
SPCTEMP
TEMP
GNDSTPT OFFSET
BK
PU
RD
BK
PU
BK
WH WH
PK
WHBR
GR
GR
BR
BL
WH
8
7
65
4
32
1
9
AI3
AI8
AI7 AI6
AI5 AI4
AI1
AI2
AGND AGND
10
WH WH
PLF
WH
WH
BL
4
5
-t°
3
BAC NET3T-21(BAC
NET)R+SH
RD
BL
BL
(SPC TMP)
(SUPPLY AIR TMP)
(SPC HUM)
(COMP PRESS 1)
(BLOWER STAGE 1)
(COMP PRESS 2)
(SPC SLIDE ADJ)
(RMT STRT/STP)
-t°
PU
BR
BL
BL
RD
GR
SMK/EMG TR1
PUYL
PU
BL/PK
BL/PK
YL
PK
YL/PKPK
YL/PK YLPK
YL
PU
BL
RD
GR
24V
RD
LINE VOLTAGE
PK
PKPKPKPK
YL BK
YL PKPU
PK
PKRD
BK
GR
YL
PU
BL
YL
BL
BL
BK
PK
BL
4
21
65
3
EXF CNTL RLYTWISTEDPAIR
GRD10VDC
ALRM CNTL RLY
GRD10VDC
BR
RD
WH
RD
RD
BR
GRGR
GR
GR BK
BK
PU
PUPU
PU
PU
PUPU
BK
BK
YL
YL
PU
PU
PU PUYL
PK
PKPKPK PKPK BL
BLBL
BLBL
BL
2
2
RDRD
GRRD
RD
PURD
BK
BK
BR
BR
BR
GR
BL
6
PK
BC1(HI SPD)
BK
BC2(LO SPD)
BL
BL
BR BR
BR
BR
(BLOWER STAGE 2)
BL
BL
BLBL
BL
GND
24VAC
1
2
BLBL
BL
0140L05824-A
NOTES:
1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE OF INSULATION AS ORIGINAL (AT LEAST 105° C). USE COPPER CONDUCTORS ONLY. USE N.E.C. CLASS 2 WIRE FOR ALL LOW VOLTAGE FIELD CONNECTIONS.
IF OPTIONAL SMOKE DETECTOR IS INSTALLED, REMOVE RED JUMPER WIRE CONNECTIONS TB1-XS TO TB1-ES.
DISCHARGE AIR TEMPERATURE SENSOR SHIPPED WITH UNIT IN CONTROL BOX.INSTALL AND CONNECT PER THE ATTACHED INSTRUCTIONS/WIRING DIAGRAM.
IF OPTIONAL ECONOMIZER IS INSTALLED, CONNECT ECON PLF TO ECONOMIZER. ECONOMIZER PLUG LOCATED IN THE RETURN AIR COMPARTMENT.
IF OPTIONAL ELECTRIC HEAT IS INSTALLED, CONNECT HTR PLF2 TO ACCESSORY HEAT PLUG IN HEAT COMPARTMENT.
SEE POWER DIAGRAM FOR CONTROL TRANSFORMER (TR1) HIGH VOLTAGE CONNECTIONS.
2
3
4
5
6
30 www.daikinac.com SS-DCC15 SS-DCC15 www.daikinac.com 31
Wiri
ng is
sub
ject
to c
hang
e. A
lway
s re
fer
to t
he w
iring
dia
gram
on
the
unit
for t
he m
ost u
p-to
-dat
e w
iring
.⚠
War
ning
High
Vol
tage
: Dis
conn
ect
all p
ower
bef
ore
serv
icin
g or
inst
allin
g th
is u
nit.
Mul
tiple
pow
er
sour
ces m
ay b
e pr
esen
t. F
ailu
re to
do
so m
ay ca
use
prop
erty
dam
age,
per
sona
l inju
ry, o
r dea
th.⚡
Wiring Diagram with DDC— DCC0180*/ DCC240* 208-230, 460, 575 / 3 / 60 2SP Power
BKBK
RD
RD
OR
T1
0140L05763-A
POWER WIRING DIAGRAMDCC(180-240)
DDC
LOW VOLTAGE
HIGH VOLTAGE
FIELD WIRING
LOW VOLTAGE
FACTORY WIRING
HIGH VOLTAGE
GR GREEN
WIRE CODE
BL BLUE
PU PURPLEPK PINK
WH WHITE
BK BLACK
RD RED
BR BROWN
OR ORANGE
YL YELLOW
GY GRAY
YL/PK YELLOW WITH PINK STRIPEBL/PK BLUE WITH PINK STRIPE
OPTIONAL LOW VOLTAGE
OPTIONAL ACCESSORIES OR FIELD SUPPLIED
BLOWER CONTACTORBC
COMPRESSOR CONTACTOR
COMPRESSOR
ECONOMIZER
HIGH PRESSURE SWITCH
POWER DISTRIBUTION BLOCKFEMALE PLUG/CONNECTOR
TERMINAL BLOCK (24V SIGNAL)
CC
COMP
ECON
HPS
PBPLF
TB
COMPONENT LEGEND
CIRCUIT BREAKERCB
TR
GND
BCS BLOWER CURRENT SWITCHBM BLOWER MOTOR
CFS CLOGGED FILTER SWITCHCF CONDENSER FAN
DAT DISCHARGE AIR TEMPERATURE SENSORDDC DIRECT DIGITAL CONTROL
CO2 CARBON DIOXIDE SENSOR
FC FAN CAPACITOR
EQUIPMENT GROUNDGV GAS VALVE
EXF EXHAUST FAN
IAH INDOOR AIR HUMIDITY SENSOR
LOW PRESSURE SWITCHLPS
RSS REMOTE START/STOP
OAT OUTDOOR AIR TEMPERATURE SENSOROAH OUTDOOR AIR HUMIDITY SENSOR
LDS LOAD SHEDDING
SPCTEMP SPACE TEMPERATURE SENSOR
TRANSFORMER
ALRM ALARM
HGRH HOT GAS REHEAT
SMK SMOKE DETECTOR
ALS AUXILIARY LIMIT SWITCH
IIC INTEGRATED IGNITION CONTROLLS LIMIT SWITCH
FS FLAME SENSE
PLM MALE PLUG/CONNECTOR
L1
L2
L3
T1
T2
T3
COMP 1
BM
L1
L2
L3
T1
T2
T3
RD
GY
BL
YL
RD
BL
BK
OR
RD
YL
BK
OR
GY
OR
RD
OR
RD
YL
BK
CCAS1
BC1
BC 2
CC1
PB
CCH1
GR
L1 L2 L3
GR
5
GND
L2
L3
L1
L1 L2 L3
LINE VOLTAGE
RD
7
L1
L2
L3
T2
T3
CB2LOW
SPEED
L1
L2
L3
T1
T2
T3
CB1HIGH
SPEED
L1
L2
L3
T1
T2
T3
RDBK
RD
BK
OR
LINEVOLTAGE
TR1
4
2,3
BK
OR
RD
ORBKBK RD OR OR
OR
GY BK
BKBK
CF1
CF3BR
PUPU
BR
BK
CF2
NOTES:1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE OF INSULATION AS ORIGINAL (USE COPPER CONDUCTORS ONLY).2. THE CONTROL TRANSFORMER HAS MULTIPLE HIGH VOLTAGE TAPS. ENSURE WIRE CONNECTIONS ARE CORRECT FOR UNIT SUPPLY VOLTAGE RATING3. 208/230V SUPPLY POWER UNITS ARE FACTORY CONNECTED TO THE CONTROL TRANSFORMER 240V TAP. MOVE WIRE CONNECTION FROM 240V TAP TO 208V TAP WHEN 208V POWER SUPPLY IS USED.4. SEE CONTROL DIAGRAM FOR CONTROL TRANSFORMER LOW VOLTAGE CONNECTIONS5. OPTIONAL; CB1,CB2,BC2 AND ASSOCIATED WIRING IS PRESENT ONLY WITH 2-SPEED EVAPORATOR MOTOR.6. USE COPPER CONDUCTORS ONLY. UNIT TERMINALS ARE NOT DESIGNED FOR OTHER CONDUCTORS.
THE USE OF OTHER TYPE CONDUCTORS MAY CAUSE DAMAGE TO THE UNIT.7. SEE ACCESSORY KIT LITERATURE FOR OPTIONAL CONVENIENCE OUTLET WIRING DIAGRAM.
BK
HVTB HIGH VOLTAGE TERMINAL BOARD
BK
BK
BK
BR
PUPU
BR
BK BKBK
BR
PUPU
FC1
BR
BK BK
PU
BR
BK BK
RD
RD
BK CFHVTB
BK
RD
OROR
COMP 2
L1
L2
L3
T1
T2
T3OR
RD
YL
BK
CCAS 2
CC2
CCH2
GR
L2
L3
L1
RD
OR
OR
BR BK
BKBK
RD
OROROR
RD
BK
BKBK
OROR
OR
RD
BK
RD
FC2
PU
BRRD
RD
FC3
PUBR
RD
BK
BK
RD
OR
BKBK
BK
OR
OR
OR
BK
ORRD
BK
RD
OR
BK
BK
OR
RD OR OR
BK BK RD OR OR
BK RD OR
RD OR
CCAS COMPRESS CONTACTOR AUXILIARY SWITCHCCH CRANK CASE HEATER
30 www.daikinac.com SS-DCC15 SS-DCC15 www.daikinac.com 31
Wiri
ng is
sub
ject
to c
hang
e. A
lway
s re
fer
to t
he w
iring
dia
gram
on
the
unit
for t
he m
ost u
p-to
-dat
e w
iring
.⚠
War
ning
High
Vol
tage
: Dis
conn
ect
all p
ower
bef
ore
serv
icin
g or
inst
allin
g th
is u
nit.
Mul
tiple
pow
er
sour
ces m
ay b
e pr
esen
t. F
ailu
re to
do
so m
ay ca
use
prop
erty
dam
age,
per
sona
l inju
ry, o
r dea
th.⚡
Wiring Diagram with DDC — DCC300* 208-230, 460, 575/3/60 2SP Control
78 6 5 4 3 2 1
014
0L06
606-
A
T1 T2LAT T6
136
5
42
LAR
1 21 2
1 2 3LAM
2PL
MPL
F
-t W
LA C
MC
LOW
AM
BO
PTIO
NL3L2
L1
1 2
1 2
1 2 3LAM
1PL
MPL
F
CM
R
24
56 3
1
7
HIG
HSP
EED
CB1
T3T2T1
L3L2L1
BC1
EM
T3T2T1
L3L2L1
T1T2
T3LA
C M
C T3T2T1
L3L2L1
PLF
PLM
FB 2
F6F5F4
321
321
FB 1
CM
C2
CM
C1
T3T2T1
L3L2L1
CM
1
F3F2F1
T3T2T1
L3L2L1
RDBR PU
BK BR
BK
BK BR
BK BR PU
GR
BK BR YL
BK YLBR
BK
PU
PUPUBK
BK RD
OR
BK RD
OR
BK RD OR
YL (1
1)YL
(13)
YL (1
2)
GR
BL
BL
PUPU
PU
GY GY
GY
BK BK
BK BK
PU
(CLA
SS2)
BK
BCS
OAT
PSC
STB
1
CFSRSS LD
S
CO
2
S MK /
E MG
2
BK
LPS1
HPS
2
YL
HPS
1
LPS2
PU
BL/P
K
BL/P
KYL
/PK
YL/P
K
YL/P
K
YL/P
K
PK
BKBK
YL
PUYL
GN
D24
VACO
AHVO
UT
(DC
)
GN
D24
VAC
(CO
M)
24 V
ACVOU
T (D
C)
VOU
T (D
C)
24 V
ACIAH G
ND
BI8
BI5
CO
M3-
8R
LY8
BI1
BI2
BI3
BI4
BI7
GN
D24
VAC
BR
RD
CO
M3-
8
RLY
7R
LY6
RLY
5R
LY4
RLY
3
CO
M1
BL
PU
PU
OAT
CFSEM
ERG
ENC
Y SH
UTD
OW
NFA
N P
RO
V SW
HEA
T/ST
G2
HEA
T/ST
G1
YL
BI6
LOAD
SHE
D
RLY
1R
LY2
CO
M2
24V
RLY
EXF
(SSR
)/VFD
ALRM
(SSR
)
ECO
N DM
PR
OAH
SPC
TM
PC
O2
SENS
OR
DD
C (
CLAS
S2)
ECO
N FE
EDBA
CK
C
GR
(CLA
SS2)
TB2
DAT
CO
MP/
STG
2C
OM
P/ST
G1
24V
RLY
1
24V
RLY
2
YL
ECO
N
AO
1 A
O2
AO
3 A
O4
GN
DG
ND
WH
AG
SPC
TEM
P TEM
P
GN
DST
PT O
FFSE
T
GR
BRBR
BKBK
PUPU
GR
GRBR
BR BR
GR
BR
BRG
R
RD
RD
RD
BL
BLBL
BL
PU
PKPK
PU
YL
BKR
DBK
BK
BK
BL/P
K
PUPU YL
PU
PU
YL
PU WH
PK
WH
WH
PKWH
BR
ALR
M-
+
EXF
-+
GR
GR
AI3
AI8
AI7
AI6
AI5
AI4
AI1
AI2
AG
ND
AG
ND
GR
WH
WH
PU
BK
PU
PLF
WH
BL
TR1
5
RD
BL
4
-t°
3
BAC
NET
T-BA
C N
ETR
+SH
+-
HG
RH
BR
BL
BL
PUPU
GR
GR
GR
BL
BLBL
BL
RD
65
43
21
BR
BR
BR
BRBR
BL
RDRD
BL
RD
BR
BR
BL
BL
24V
CNT
LVO
LTA G
E
LINE
VOLT
A GE
RD
BL
RD
BL
BL
SUPP
LY A
IR T
MP
MO
D H
GR
H
SPC
HUM
CO
MP
PRES
S SW
1
BLO
WER
/STG
1
CO
MP
PRES
S SW
2
SPC
SLI
DE
ADJ
RM
T ST
RT/
STP
BK
-t°
FSW
24VA
CRD
RD
T1T2
T3T4
1 2
1 2
1 2 3
FM2
PLM
PLF
-tW
1 2
1 2
1 2 3
FM1
PLM
PLF
-tW
YL
BLO
WER
/STG
2/EX
F
CO
ND
FAN
(S)
REV
VAL
VE/L
AT
DEF
RO
ST S
W (E
S)
BK
YL BL BK
RD
RD
RD
RD
OR
OR
OR
OR
WH
WH
WH
WH
BLPU
BK
YL
PU
PUPU
BL
BLBL
BK
BK
RD
RD
YLBL
BK
BL
BK
1 1
1 2
RD
RD
PK
PK
PK
RD
RD
RD
RD
PK
BR
BRBK
BRBK
BR
BK
BR
YL
RD
RD RD
BK
BK
BK BK
BLBL
BLBL
9
T3T2T1
L3L2L1
LOW
SPEE
D
CB2
T3T2T1
L3L2L1
BC 2
BR BK RD
OR
YL BL GY
YL BL GY
BK (1
)
BK (3
)BK
(2)
PUPU
BL
BL
BL
BL
BL
BL
BL
BL
8
13
8
L3L2
L1
L1 L3
L2
GN
D
L1C
CH2
CC
H1
PB
CC
1
CC2
CC
AS2
CC
AS1
PU
T3T2T1
L3L2L1
CO
MP1
RD
LIN
E VO
LTAG
EL3
L2L1
PHAS
E M
ON
ITO
R10
YL
BK RD YL
BK RD
PU
BK
BK
GY
GY
GY
BK BKG
R
BK
PUBK
BKBL
PU
BL
BKBR
PU
BL
BL
101 2
1 1
PKPK
PK
BKBK
24V
RLY
BR
BL
BL
BK
PU PUYL
YL
YL RD
RD
RDYL BK O
R
GY
BL
WH
OR
BKYL
RD
OR
BK YL
RD
BLBL
BLBL
GY
BLW
HW
HW
HW
HW
H
-tW
WH
WH
RD
BL
BL
GY
BK
RD
L2L3
YL
PU
BK
RD
BLBL
GY
BL
BRWH
PUYL
RD
RD
RD
YLYLR
D
RD
RD
BK
RD
T5XS
DA
ES
BL
BL
PKR
D
BK
BKR
D
RD
BK
BL
PUYL
GR
L1 L3
L2T3T2T1
L3L2L1
CO
MP2
PURD
BKPU
PU
GY
GY
L3L2
L1
PLF
PLM321
321C
M2
GR
BK BR PU
BK BR PU
BRBK
BL
GY
BK
RD
BR
BL
OR
BK RD
OR
BK
BK BK
RD
RD
RD
OR
PU
YLRDBK
BRBK
BR
PU
BR
POW
ER &
CO
NTR
OL
WIR
ING
DIA
GR
AMD
CC
(300
) ***
(3,4
,6,7
) (B,
V)
DD
C
GR
GRE
EN
WIR
E C
OD
E
BL
B
LUE
PU
P
UR
PLE
PK
P
INK
WH
WH
ITE
BK
B
LAC
K
RD
RED
BR
B
RO
WN
OR
ORA
NGE
YL
Y
ELLO
W
GY
GRA
Y
BLO
WER
CO
NTAC
TOR
BC
CO
MPR
ESSO
R C
ONT
ACTO
R
CO
MPR
ESSO
R
ECO
NOM
IZER
HIG
H PR
ESSU
RE S
WIT
CH
POW
ER D
ISTR
IBU
TIO
N BL
OCK
FEM
ALE
PLU
G/C
ONN
ECTO
R
TER
MIN
AL B
LOCK
(24V
SIG
NAL)
CC CO
MP
ECO
N
HPS
PB PLF
TB
CO
MPO
NEN
T LE
GEN
D
CIR
CUI
T BR
EAKE
RC
B GND
BCS
BLO
WER
CU
RREN
T SW
ITC
H
CFS
CLO
GG
ED F
ILTE
R S
WIT
CH
DAT
DISC
HAR
GE
AIR
TEM
PERA
TURE
SEN
SOR
DD
CDI
REC
T D
IGIT
AL C
ONT
RO
L
CO
2C
ARBO
N D
IOXI
DE
SEN
SOR
FCFA
N C
APAC
ITO
R
EQUI
PMEN
T G
ROUN
D
EXF
EXH
AUST
FAN
IAH
INDO
OR
AIR
HUM
IDIT
Y SE
NSO
R
LOW
PR
ESSU
RE S
WIT
CH
LPS
RSS
REM
OTE
STA
RT/S
TOP
OAT
OUT
DO
OR
AIR
TEM
PERA
TURE
SEN
SOR
OAH
OUT
DO
OR
AIR
HUM
IDIT
Y SE
NSO
R
LDS
LOAD
SH
EDDI
NG
SPC
TEM
PSP
ACE
TEM
PERA
TURE
SEN
SOR
YL/P
K Y
ELLO
W W
ITH
PIN
K ST
RIP
EBL
/PK
BLU
E W
ITH
PIN
K ST
RIP
E
ALR
MAL
ARM
HG
RH
HO
T G
AS R
EHEA
T
SMK
SMO
KE D
ETEC
TOR
H
IGH
VOLT
AGE
FIEL
DW
IRIN
G
L
OW
VO
LTAG
E
FAC
TORY
WIR
ING
OPT
ION
AL
AC
CESS
OR
IES
OR
FIE
LD S
UPP
LIED
CO
MPO
NEN
TS
OPT
IONA
L L
OW
VO
LTAG
E
NO
TES:
2 3 4 5
PSPR
ESSU
RE
SWIT
CH
FMFR
EEZE
STA
T M
ODU
LE
H
IGH
VOLT
AGE
L
OW
VO
LTAG
E
PLM
MAL
E PL
UG
/CO
NNEC
TOR
6
7 8 9 10 11 12
FSW
FLO
AT S
WIT
CH
PMPH
ASE
MO
NITO
R
CO
ND
ENSE
R M
OTO
RC
M
CR
ANK
CAS
E H
EATE
RC
CH
CO
ND
ENSE
R M
OTO
R C
ONT
ACTO
RCM
C
CC
AUX
SW
ITC
HC
CAS
FUS
E BL
OCK
FB
CO
ND
ENSE
R M
OTO
R RE
LAY
CMR
LACM
CLO
W A
MBI
ENT
COND
ENSE
R M
OTO
RC
ON
TAC
TOR
LAM
LOW
AM
BIEN
T M
ODU
LELA
RLO
W A
MBI
ENT
REL
AYLO
W A
MBI
ENT
TIM
ERLA
T
EVAP
ORA
TOR
MO
TOR
EM
I
F LO
W A
MBI
ENT
KIT
IS IN
STAL
LED
, DIS
CO
NN
ECT
CO
ND
ENSE
R
MO
TOR
WIR
ES F
RO
M C
MC1
(T1,
T2,
T3)
AN
D C
ON
NEC
T TO
C
OR
RES
PON
DIN
G (B
K, B
R, Y
L) W
IRES
WIT
H Q
UIC
K C
ON
NEC
T
TER
MIN
ALS
FRO
M L
AC M
C (T
1, T
2, T
3). C
ON
NEC
T (B
K, B
R, Y
L)
FR
OM
LAC
MC
(L1,
L2,
L3)
TO
CM
C1
(T1,
T2,
T3)
.
I
F LO
W A
MBI
ENT
KIT
IS IN
STAL
LED
, CO
NN
ECT
GY
WIR
E FR
OM
L
AM2
- 3 T
O C
MR
-4. A
LSO
CO
NN
ECT
BL C
OM
WIR
ES F
RO
M L
AT-
T
6 AN
D L
AM2
-2 T
O T
B 2
(24V
CO
M).
O
PTIO
NAL
; CB1
, CB2
, BC
2 AN
D A
SSO
CIA
TED
WIR
ING
IS P
RES
ENT
O
NLY
WIT
H 2
-SPE
ED E
VAPO
RAT
OR
MO
TOR
. WH
EN P
RES
ENT,
BK
W
IRE
FRO
M D
DC
CO
NTR
OLL
ER IN
STAL
LED
ON
BC2
AN
D B
R W
IRE
FRO
M D
DC
INST
ALLE
D O
N B
C1.
I
F 3
PHAS
E LI
NE
VOLT
AGE
MO
NIT
OR
IS IN
STAL
LED
,CO
NN
ECT
P
HAS
E M
ON
ITO
R L
1, L
2, L
3 TO
TH
E U
NIT
PO
WER
BLO
CK
R
ESPE
CTI
VELY
. ALS
O, R
EMO
VE J
UM
PER
WIR
E C
ON
NEC
TIO
NS
T
B1 -
ES T
O T
B1- P
M .
I
F FL
OAT
SW
ITC
H IS
INST
ALLE
D, R
EMO
VE J
UM
PER
WIR
E
CO
NN
ECTI
ON
S TB
1- P
M T
O T
B1 -
FSW
.
I
F FR
EEZE
PR
OTE
CTIO
N M
OD
ULE
IS IN
STAL
LED
, REM
OVE
JU
MPE
R
CO
NN
ECTI
ON
S TB
1- P
S TO
TB1
- FM
1 AN
D T
B1 -
FM1
TO T
B1 -
FM2.
L
AT O
N/O
FF T
IME
SETT
ING
S:
ON
- TI
ME
(LEF
T C
OLU
MN
) : 2
,8 =
ON
O
FF -
TIM
E ( R
IGH
T C
OLU
MN
) : 8
= O
N
ALL
OTH
ER D
IP S
WIT
CH
ES O
FF
1. R
EPLA
CEM
ENT
WIR
E M
UST
BE
SAM
E SI
ZE A
ND
TYPE
OF
INSU
LATI
ON
AS O
RIG
INAL
(AT
LEAS
T10
5° C
). U
SE C
OPP
ERC
ON
DU
CTO
RS O
NLY.
U
SE N
.E.C
. CLA
SS 2
WIR
E FO
R AL
L LO
W V
OLT
AGE
FIEL
DC
ON
NEC
TIO
NS.
IF O
PTIO
NAL
SMO
KE D
ETEC
TOR
IS IN
STAL
LED
, REM
OVE
RED
JUM
PER
WIR
EC
ONN
ECTI
ONS
TB1
-XS
TOTB
1-ES
.
DISC
HAR
GE
AIR
TEM
PERA
TURE
SEN
SOR
SHIP
PED
WIT
H U
NIT
INC
ON
TRO
L BO
X.IN
STAL
L AN
D C
ONN
ECT
PER
THE
ATTA
CHE
DIN
STR
UCTI
ONS
/WIR
ING
DIA
GRA
M.
IF O
PTIO
NAL
ECO
NO
MIZ
ER IS
INST
ALLE
D, C
ON
NEC
T EC
ON
PLF
TO
ECO
NOM
IZER
. ECO
NOM
IZER
PLU
G L
OCA
TED
IN T
HE
RET
URN
AIR
CO
MPA
RTM
ENT.
(208
/230
)V U
NITS
: IF
UNI
T UT
ILIZ
ES 2
08V
SUPP
LY P
OW
ER, M
OVE
TR1/
2 H
IGH
VOLT
AGE
RED
WIR
E FR
OM
TH
E 24
0V T
ERM
INAL
TO
THE
208V
TER
MIN
AL 4
60V,
575
V U
NITS
: RED
WIR
E C
ONN
ECTE
DTO
APPR
OPR
IATE
HIG
H VO
LTAG
E IN
PUT
TER
MIN
ALO
NTR
1/2
IF O
PTIO
NAL
ELEC
TRIC
HEA
T IS
INST
ALLE
D, C
ON
NEC
T H
TR P
LF2
TOAC
CESS
ORY
HEA
T PL
UG
IN H
EAT
CO
MPA
RTM
ENT.
13
TRTR
ANSF
ORM
ER
TB1-
T1
FM
1 (F
REEZ
E M
ONI
TOR
1)TB
1-T2
F
M2
(FRE
EZE
MO
NITO
R2)
TB1-
T3
PM
(PH
ASE
MO
NITO
R)TB
1-T4
F
SW (F
LOAT
SW
ITC
H)TB
1-T5
U
NU
SED
RD
1
9
BL
BL
BL
BL
BL
BL
BL
BL
6H
TR P
LF2
PKPU YL
PUBL
/PK
YL
32 www.daikinac.com SS-DCC15 SS-DCC15 www.daikinac.com 33
Accessories
Daikin Installed Item # Description Fits
Model SizesField-
InstalledFactory- Installed
Operating Weight (lbs)
Curb
14CURB180300 14” Roof Curb 15-25 tons √ 285
18CURB180300 18” Roof Curb 15-25 tons √ 315
24CURB180300 24” Roof Curb 15-25 tons √ 360
GHRC-180300 Hurricane Restraint Clips 15-25 tons √ 2
Ultra Low-Leak Economizer & Power Exhaust1
10-366-11 Ultra Low-Leak Downflow Economizer w/ Enthalpy 15-25 tons √ √ 281
10-465-11-21 Prop Power Exhaust 230v 15-25 tons √ 98
10-465-11-31 Prop Power Exhaust 460v 15-25 tons √ 98
10-465-11-41 Prop Power Exhaust 575v 15-25 tons √ 98
Low-Leak Economizer & Power Exhaust2
DDNECNJ180300B Low-Leak Downflow Economizer 15-25 tons √ √ 416
DPE1803002 Downflow Power Exhaust (208/230v) 15-25 tons √ 200
DPE1803004 Downflow Power Exhaust (460v) 15-25 tons √ 200
DPE1803007 Downflow Power Exhaust (575v) 15-25 tons √ 200
DHZECNJ180300 Horizontal Economizer 15-25 tons √ 225
Downflow Accessories
D25FD180300 25% Manual Fresh Air Damper 15-25 tons √ 34
D25MFD180300 25% Motorized Fresh Air Damper 15-25 tons √ 42
D50MFD180300 50% Motorized Fresh Air Damper 15-25 tons √ 42
DDNBB180300 Burglar Bar Sleeves with Supply and Return 15-25 tons √ 60
Horizontal Accessories
HZCURB180300EDR Horizontal Curb End Discharge Roofed In 15-25 tons √ 950
HZCURB180300NSRHorizontal Curb Non-Service Side Discharge Roofed In
15-25 tons √ 950
HZCURB180300SSR Horizontal Curb Service Side Discharge Roofed In 15-25 tons √ 950
HZCURB180300EDS Horizontal Curb End Discharge Slab Mount 15-25 tons √ 850
HZCURB180300NSSHorizontal Curb Non-Service Side Discharge Slab Mount
15-25 tons √ 850
HZCURB180300SSS Horizontal Curb Service Side Discharge Slab Mount 15-25 tons √ 850
DHZE25FD180300 Horizontal Fresh Air Damper 25% 15-25 tons √ 75
DHZRETPNL180300 Horizontal Return Panel 15-25 tons √ 50
Concentrics
CDK180 Concentric Duct Kit 15 tons √ 158
CDK240 Concentric Duct Kit 20 tons √ 197
CDK300 Concentric Duct Kit Flush Mount Diffuser 25 tons √ 244
3 phase 208-230V Electric Heat Kits
EHK3-31 30kw 208-230v 3ph Electric Heat Kit 15-25 tons √ √ 21
EHK3-46 40kw 208-230v 3ph Electric Heat Kit 15-25 tons √ √ 21
EHK3-60 60kw 208-230v 3ph Electric Heat Kit 15-25 tons √ √ 21
EHK3-75 75kw 208-230v 3ph Electric Heat Kit 20 - 25 tons √ √ 21
32 www.daikinac.com SS-DCC15 SS-DCC15 www.daikinac.com 33
Accessories
Daikin Installed Item # Description Fits
Model SizesField-
InstalledFactory- Installed
Operating Weight (lbs)
3 phase 460V Electric Heat Kits
EHK4-31 30kw 460v 3ph Electric Heat Kit 15-25 tons √ √ 21
EHK4-46 40kw 460v 3ph Electric Heat Kit 15-25 tons √ √ 21
EHK4-60 60kw 460v 3ph Electric Heat Kit 15-25 tons √ √ 21
EHK4-75 75kw 460v 3ph Electric Heat Kit 20 - 25 tons √ √ 21
3 phase 575V Electric Heat Kits
EHK7-31 30kw 575v 3ph Electric Heat Kit 15-25 tons √ √ 21
EHK7-46 40kw 575v 3ph Electric Heat Kit 15-25 tons √ √ 21
EHK7-60 60kw 575v 3ph Electric Heat Kit 15-25 tons √ √ 21
EHK7-75 75kw 575v 3ph Electric Heat Kit 20 - 25 tons √ √ 21
DDC Accessories3
DDC communicating controller (built-in BACnet® MS/TP) includes Standard Room Sensor to be installed in field
15-25 tons √ 2
10366D11B DDC Ultra Low-Leak Downflow Economizer 15-25 tons √ √ 71
10465DDCPower Exhaust kit used with DDC Ultra Low-Leak Economizer
15-25 tons √ 1
DLAKT03 Low-Ambient 15-20 tons √ √ 2
LONKT01 LonWorks® card 15-25 tons √ 1
3PMK01 Phase Monitor (3-Phase Only) 15-25 tons √ √ 2
DFSKT02 Dirty Filter Switch 15-25 tons √ 1
High-Static Kits
HSKTW180-3FI High static, factory-installed, 230V 15 ton, AC only √ 80
HSKTW180-4FI High static, factory-installed, 460V 15 ton, AC only √ 80
HSKTW180-7FI High static, factory-installed, 575V 15 ton, AC only √ 80
HSKTW240-3FI High static, factory-installed, 230V 20 ton √ 50
HSKTW240-4FI High static, factory-installed, 460V 20 ton √ 50
HSKTW240-7FI High static, factory-installed, 575V 20 ton √ 50
HSKTW300AC-FI High static, factory-installed, 25 ton, all voltages 25 ton, AC only √ 8
Crankcase Heater Kits
0130L00017S 70W 230V 15-20 tons √ 1
0130L00018S 70W 460V 15-20 tons √ 1
0130L00019S 70W 575V 15-20 tons √ 1
0130L00020S 90W 230V 25 tons √ 1
0130L00021S 90W 460V 25 tons √ 1
0130L00022S 90W 575V 25 tons √ 1
High Efficiency Filters
0160L00202High Efficiency MERV 13 Air Filter Nom. Size: 20x25x2; (Order Qty 6)
15, 20 tons √ 9
0160L00201High Efficiency MERV 13 Air Filter Nom. Size: 20x20x2; (Order Qty 8)
25 tons √ 11
34 www.daikinac.com SS-DCC15 SS-DCC15 www.daikinac.com 35
Daikin Installed Item # Description Fits
Model SizesField-
InstalledFactory- Installed
Operating Weight (lbs)
Misc Accessories
Convenience Outlet: Powered 15-25 tons √ 42
Convenience Outlet: Non Powered 15-25 tons √ 2
Disconnect Switch (non-fused) 15-25 tons √ 5
LAKT23 Low-Ambient Kit, 208-230V - non-DDC 15-20 tons √ √ 32
LAKT24 Low-Ambient Kit, 460V - non-DDC 15-20 tons √ √ 32
LAKT25 Low-Ambient Kit, 575V - non-DDC 15-20 tons √ √ 32
LAKT05 Low-Ambient Kit (all voltages) - non-DDC 25 tons √ √ 2
3PMNDK01 Phase Monitor - Non DDC 15-25 tons √ √ 2
Smoke Detector (supply and/or return air) 15-25 tons √ 11
Hinged Panels 15-25 tons √ 34
FSKT02A Freeze Stat Kit4 25 tons √ 11 Use Economizer & Power Exhaust listed within Ultra Low-Leak section 2 Use Economizer & Power Exhaust listed within Low-Leak section 3 For a full list of DDC accessories, please refer to DDC Controller Technical Guide manual (DK-DDC-TGD-01B)4 FSK02A is standard on 2 speed, V, models.Note: Where multiple variations are available, the heaviest combination is listed.
Accessories
34 www.daikinac.com SS-DCC15 SS-DCC15 www.daikinac.com 35
Notes
36 www.daikinac.com SS-DCC15 SS-DCC15 www.daikinac.com PB
Our continuing commitment to quality products may mean a change in specifications without notice. © 2017 • Houston, Texas • Printed in the USA.
Notes