SS-DCH7 www.daikinac.com 2/18Supersedes 1/18
Cooling Capacity: 90,000 — 140,000 BTU/h
Heating Capacity: 90,000 — 142,000 BTU/h
DCH Commercial7½ - 12½ Ton Packaged Heat Pump
Up to 11.5 EER & 3.4 COP
■ ContentsNomenclature ..............................2Product Specifications .................4Expanded Cooling Data ................8Expanded Heating Data ............16Airflow Data ...............................18 Crankcase Heater .......................22Electrcial Data / Heat Kit Data ...23Dimensions ................................31Wiring Diagrams .......................35 – for Models with DDC Controls ......39Accessories ................................42
■ Standard Features• High-efficiency scroll compressors• Two-stage cooling• Copper tube / aluminum fin coils• Power block for field wiring• High-capacity, steel-cased filter drier• Single-point entry• 24-volt terminal strip• Convertible airflow orientation• Easy to service• Built-in filter rack with standard 2” filters• AHRI Certified; ETL Listed• Units meet the performance outlined in
Table 6.8.1-2 of ASHRAE Standard 90.1-2013
■ Cabinet Features• Heavy-gauge, galvanized-
steel cabinet with UV-resis-tant powder-paint finish
• Full perimeter rail• Sloped drain pan
*Model shown is a gas/electric
* Complete warranty details available from your local dealer or at www.daikincomfort.com.
2 www.daikinac.com SS-DCH7 SS-DCH7 www.daikinac.com 3
Nomenclature
D C H 090 045 3 V * * * A *1 2 3 4,5,6 7,8,9 10 11 12 13 14 15 16
Revision LevelsMajor & Minor
Brand Factory-Installed OptionsD Daikin X No Options
A Non-powered convenience outletConfiguration B Powered convenience outletC Standard Efficiency (6 - 25 Tons) C Low-ambient kitS Standard Efficiency (3 - 5 Tons) D Return air smoke detectorT High Efficiency (3 - 5 Tons) E Supply air smoke detector
F Non-powered convenience outlet; Application Low-ambient kitC Cooling1 G Non-powered convenience outlet; G Gas Heat Return air smoke detectorH Heat Pump1 H Non-powered convenience outlet;
Supply air smoke detectorNominal Cooling Capacity J Non-powered convenience outlet;036 3 Tons 102 8½ Tons 300 25 Tons Return & Supply air smoke detectors048 4 Tons 120 10 Tons K Non-powered convenience outlet;060 5 Tons 150 12½ tons Low-ambient kit; Supply air smoke detector072 6 Tons 180 15 Tons L Non-powered convenience outlet; 090 7½ Tons 240 20 Tons Low-ambient kit
Return & Supply air smoke detectorsNominal Heating Capacity M Powered convenience outlet;
Gas/Electric A/C H/P Factory-Installed Electric Heat Low-ambient kit045 45,000 BTU/h XXX No Heat N Powered convenience outlet;090 90,000 BTU/h 010 10 kW 030 30 kW Return air smoke detector115 115,000 BTU/h 015 15 kW 031 30 kW O Powered convenience outlet;140 140,000 BTU/h 016 15 kW 045 45 kW Return & Supply air smoke detectors210 210,000 BTU/h 018 18 kW 046 45 kW P Powered convenience outlet;350 350,000 BTU/h 020 20 kW 060 60 kW Supply air smoke detector400 400,000 BTU/h 025 25 kW Q Powered convenience outlet; Low-ambient
See product specifications for heat size(s) available for each capacity. kit; Return air smoke detectorR Powered convenience outlet; Low-ambient
Voltage kit; Supply air smoke detector1 208-230/1/60 (DS* & DT* 3-5 Tons models only) 4 460/3/60 T Powered convenience outlet; Low-ambient3 208-230/3/60 7 575/3/60 kit; Return & Supply air smoke detectors
U Non-powered convenience outlet;Supply Fan/Drive Type/Motor Low-ambient kit; Return air smoke detectorB Belt Drive (3-5 Tons single speed models only) V Two-Speed Belt Drive V Low-ambient kit; Return air smoke detectorD Direct Drive (3-5 Tons single speed models only) (6-25 Tons only) W Low-ambient kit; Supply air smoke detectorH High Static (3-5 Tons single-speed Belt W High Static (6-25 Tons Y Low-ambient kit; Return & Supply
Drive models only) two-speed Belt Drive air smoke detectorsmodels only) Z Return & Supply air smoke detectors
Factory-Installed OptionsA Ultra Low-Leak Downflow Economizer R Ultra Low-Leak Downflow Economizer;B DDC-BACnet protocol DDC-BACnet protocol; F Ultra Low-Leak Downflow Economizer; Disconnect Switch (non-fused) Factory-Installed Options
DDC-BACnet protocol V Low-Leak Downflow Economizer X Standard Aluminized Heat ExchangerH Disconnect Switch (non-fused) W Low-Leak Downflow Economizer S Stainless-Steel Heat ExchangerJ Ultra Low-Leak Downflow Economizer; Disconnect Switch (non-fused) D Hinged Panels
Disconnect Switch (non-fused) X No Options K Stainless-Steel Heat Exchanger; M Disconnect Switch (non-fused); DDC-BACnet protocol Hinged Panels
B Phase MonitorNote: Not all options available for all products. J Stainless Steel Heat Exchanger; Phase Monitor
1 X= No Options in character 13th M Hinged Panel; Phase MonitorL Stainless-Steel Heat Exchanger;
Hinged Panels; Phase Monitor
2 www.daikinac.com SS-DCH7 SS-DCH7 www.daikinac.com 3
Nomenclature
Factory-Installed Options• Stainless-Steel Heat Exchanger (Gas units only): A tubular heat exchanger made of 409-type stainless steel is installed in the unit.• Low-Ambient Kit: Allows for cooling operation at lower outdoor temperatures. On the 3- to 6-ton units, cooling operation is extended
from 60°F ambient temperature to 35°F outside air temperature. On 7½ -20 ton units, cooling operation is extended from 35°F ambient temperature to 0°F outside air temperature. For 25 ton units, cooling operation is extended from 24°F ambient temperature to 0°F outside air temperature.
• Economizers (Downflow): Based on air conditions, can provide outside air to cool the space.• Electric Heat Kits (AC and heat pump units only): Available in all voltage options.• Non-powered Convenience Outlet: A 120V, 15A, GFCI outlet makes it easier for technicians to service the unit once an electrician runs
power to the outlet.• Powered Convenience Outlet: A 120V, 15A, GFCI outlet powered with a transformer built into the unit. When a factory-installed powered
convenience outlet is installed in the equipment, the unit MCA (Min. Circuit Ampacity) will increase by 7.2A/6.5A for 208/230V units, increase by 3.3A for 460V units, and by 2.6A for 575V units. The MOP (Max. Overcurrent Protection) device must be sized accordingly.
• Disconnect Switch (non-fused; 3-phase units only): A disconnect switch is installed in the unit and factory wiring will be complete from the switch to the unit. Please note that for air conditioning (DSC units) and heat pump models (DSH units), the appropriate electric heat kit must be ordered to be factory-installed along with the disconnect switch (non-fused) when it is ordered. Please note that for models with a powered convenience outlet option and a disconnect switch (non-fused) option, the power to the powered convenience outlet will be shut off when the disconnect switch (non-fused) is in the off position.
• Return Air and/or Supply Air Smoke Detectors: Return air and/or supply air smoke detectors are installed in the unit.• Hinged Access Panels: Allows access to unit’s major components. Combined with latches for easy access to control box, compressor,
filters and blower motor. Available on all units.• Phase Monitor: Phase monitor (3 phase only), available for 3 - 25 ton DS, DC and DT series models. Phase monitor shall provide protection
for motors and compressors against problems caused by phase loss, phase reversal and phase unbalance. Phase monitor is equipped with an LED that provides an ON or FAULT indicator.
• DDC Controller: DDC communicating controller, available for 3 - 25 ton DS, DC and DT series models with on-board BACnet® communication interface.
• High static belt drive assembly, factory installed.
4 www.daikinac.com SS-DCH7 SS-DCH7 www.daikinac.com 5
DCH090***3V***A*
DCH090***4V**A*
DCH090***7V***A*
Cooling CapacityTotal BTU/h 90,000 90,000 90,000Sensible BTU/h 65,700 65,700 65,700EER / IEER 11.5 / 12.8 11.5 / 12.8 11.5 / 12.8Decibels 83 83 83AHRI Reference #s 7041912 7041912 7041912
Heating CapacityBTU/h / COP (47° F) 90,000 / 3.4 90,000 / 3.4 90,000 / 3.4BTU/h / COP (17° F) 52,000 / 2.4 52,000 / 2.4 52,000 / 2.4
Evaporator Motor / CoilMotor Type 2-speed Belt Drive 2-speed Belt Drive 2-speed Belt DriveIndoor Nominal CFM 3,000 3,000 3,000Indoor Motor FLA (Cooling) 6.0 2.9 2.4Horsepower - RPM 2.0/1740-1160 2.0/1740-1160 2.0/1745-1170Piston Size (Cooling) 0.076 0.076 0.078Filter Size (Qty) (4) 16" x 24" x 2" (4) 16" x 24" x 2" (4) 16" x 24" x 2"Drain Size (NPT) ¾" ¾" ¾"R-410A Refrigerant Charge: Cir #1/ #2 220 oz. 220 oz. 200 oz.Evaporator Coil Face Area (ft²) 10.2 10.2 10.2Rows Deep / Fins per Inch 4/16 4/16 4/16
Belt Drive Evap Fan Data# of Wheels (D x W) 1 (15" x 12") 1 (15" x 12") 1 (15" x 12")Motor Sheave / Blower Sheave VL40 / AK74 VL40 / AK74 VL40 / AK74Belt AX51 AX51 AX51
Condenser Fan / CoilQuantity of Condenser Fan Motors 2 2 2Horsepower - RPM ¼ - 1090 ¼ - 890 ¼ - 1075Fan Diameter / # Fan Blades 22 / 4 22 / 4 22 / 4Outdoor Nominal CFM 0 0 0Face Area (ft²) 7,600 7,600 7,600# Coils / Rows Deep - Fins per Inch 2/2/20 2/2/20 2/2/20Piston Size (Heating) 0.052 0.052 0.052
CompressorQuantity / Type / Stage 2 / Scroll / 1 2 / Scroll / 1 2 / Scroll / 1Compressor RLA / LRA 13.1 / 83.1 6.1 / 41.0 4.4 / 33.0
Electrical DataVoltage / Phase / Frequency 208/230-3-60 460-3-60 575-3-60Indoor Blower HP / FLA 2/6.0 2/2.9 2/2.4Max External Static 1.0" 1.0" 1.0"Outdoor Fan HP / FLA ¼ / 1.4 ¼ / 0.7 ¼ / 0.55Min. Circuit Ampacity¹ 38.4 / 38.4 18 13.4Max. Overcurrent Protection (amps)² 50 / 50 20 15Entrance Power Supply & Entrance Control Voltage Locating Dimple Locating Dimple Locating Dimple
Operating Weight (lbs) 1,135 1,135 1,135Ship Weight (lbs) 1,175 1,175 1,175
¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.² May use fuses or HACR-type circuit breakers of the same size as noted.Note: Always check the S&R plate for electrical data on the unit being installed.
Product Specifications — 7 ½ Tons
4 www.daikinac.com SS-DCH7 SS-DCH7 www.daikinac.com 5
DCH102***3V***A*
DCH102***4V***A*
DCH102***7V***A*
Cooling CapacityTotal, BTU/h 100,000 100,000 100,000Sensible BTU/h 69,000 69,000 69,000EER / IEER 11.1 / 13.0 11.1 / 13.0 11.1 / 13.0Decibels 83 83 83ARI Reference #s 7370925 7370925 7370925
Heating Capacity
BTU/h / COP (47° F) 102,000 / 3.4 102,000 / 3.4 102,000 / 3.4
BTU/h / COP (17° F) 55,500 / 2.25 55,500 / 2.25 55,500 / 2.25
Evaporator Motor / CoilMotor Type 2-speed Belt Drive 2-speed Belt Drive 2-speed Belt DriveIndoor Nominal CFM 3,400 3,400 3,400Indoor Motor FLA (Cooling) 6.0 2.9 2.4Horsepower - RPM 2.0/1740-1160 2.0/1740-1160 2.0/1745-1170Piston Size (Cooling) 0.08 0.08 0.08Filter Size (in.) (Qty) (4) 16 x 24 x 2 (4) 16 x 24 x 2 (4) 16 x 24 x 2Drain Size (NPT) 3/4" 3/4" 3/4"R-410A Refrigerant Charge Cir #1 & #2 (oz.) 235/225 235/225 235/225Evaporator Coil Face Area (ft²) 10.2 10.2 10.2Rows Deep / Fins per Inch 4 / 14 4 / 14 4 / 14
Belt Drive Evap Fan Data# of Wheels (D x W) 1 (15" x 12") 1 (15" x 12") 1 (15" x 12")Motor Sheave / Blower Sheave VL40 / AK74 VL40 / AK74 VL40 / AK74Belt AX51 AX51 AX51
Condenser Fan / CoilQuantity of Condenser Fan Motors 2 2 2Horsepower - RPM 1/4" - 1,090 1/4" - 890 1/4" - 1,075Fan Diameter / # Fan Blades 22 / 4 22 / 4 22 / 4Outdoor Nominal CFM 7,600 7,600 7,600Face Area (ft²) 32.4 32.4 32.4Rows Deep / Fins per Inch 2 / 22 2 / 22 2 / 22Piston Size (Heating) 0.059 0.059 0.059
CompressorQuantity / Type / Stage 2 / Scroll / 1 2 / Scroll / 1 2 / Scroll / 1Compressor RLA / LRA ea. 14.5 / 98 6.3 / 55 6.0 / 41
Electrical Data / StaticVoltage / Phase / Frequency 208/230-3-60 460-3-60 575-3-60Standard Motor Max. External Static 1" 1" 1"Outdoor Fan FLA ea. 1.4 0.7 0.55Min. Circuit Ampacity¹ 43.2 / 43.2 19.4 17.8Max. Overcurrent Protection (amps)² 50 / 50 25 20Entrance Power Supply & Control Voltage Locating Dimple Locating Dimple Locating Dimple
Operating Weight (lbs) 1,285 1,285 1,285Ship Weight (lbs) 1,310 1,310 1,310
¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.² May use fuses or HACR-type circuit breakers of the same size as noted.Note: Always check the S&R plate for electrical data on the unit being installed.
Product Specifications — 8 ½ Tons
6 www.daikinac.com SS-DCH7 SS-DCH7 www.daikinac.com 7
DCH120***3V***A*
DCH120***4V***A*
DCH120***7V***A*
Cooling CapacityTotal BTU/h 113,000 113,000 113,000Sensible BTU/h 84,700 84,700 84,700EER / IEER 11.1 / 12.6 11.1 / 12.6 11.1 / 12.6Decibels 83 83 83ARI Reference #s 6345706 6345706 6345706
Heating CapacityBTU/h / COP (47° F) 116,000 / 3.4 116,000 / 3.4 116,000 / 3.4BTU/h / COP (17° F) 56,000 / 2.4 56,000 / 2.4 56,000 / 2.4
Evaporator Motor / CoilMotor Type 2-speed Belt Drive 2-speed Belt Drive 2-speed Belt DriveIndoor Nominal CFM 3,500 3,500 3,500Indoor motor FLA (Cooling) 6.4 3.0 2.4Horsepower - RPM 2.0/1725 2.0/1750-1165 2.0/1750-1165Piston Size (Cooling) 0.086 0.086 0.086Expansion Device Orifice Orifice Orifice Filter Size (in.) (Qty = 4) 16 x 24 x 2 16 x 24 x 2 16 x 24 x 2Drain Size (NPT) ¾" ¾" ¾"R-410A Refrigerant Charge Cir #1 & #2 (oz.) 225 / 225 225 / 225 225 / 225Evaporator Coil Face Area (ft²) 10.2 10.2 10.2Rows Deep/ Fins per Inch 4 / 14 4 / 14 4 / 14
Belt Drive Evap Fan Data# of Wheels (D x W) (1) 15" x 15" (1) 15" x 15" (1) 15" x 15"Motor Sheave / Blower Sheave VL40 / AK74 VL40 / AK74 VL40 / AK74Belt AX50 AX50 AX50
Condenser Fan / CoilQuantity of Condenser Fan Motors 2 2 2Horsepower - RPM ⅓ - 1,075 ⅓ - 1,075 ⅓ - 1,075Fan Diameter / # Fan Blades 22 / 3 22 / 3 22 / 3Outdoor Nominal CFM 8,200 8,200 8,200Face Area (ft²) 32.4 32.4 32.4# Coils / Rows Deep - Fins per Inch 2 / 2 - 22 2 / 2 - 22 2 / 2 - 22Piston Size (Heating) 0.064 0.064 0.064
CompressorQuantity / Type / Stage 2 / Scroll / 1 2 / Scroll / 1 2 / Scroll / 1Compressor RLA / LRA ea. 16 / 110.0 7.8 / 52.0 5.7 / 38.9
Electrical DataVoltage/Phase/ Frequency 208/230-3-60 460-3-60 575-3-60Belt-Driven Standard Max Static 1.4 1.4 1.4Outdoor Fan RLA ea. 2.00 0.85 0.85Min. Circuit Ampacity¹ 46.3 / 46.3 22.2 16.6Max. Overcurrent Protection (amps)² 60 / 60 25 20Entrance Power Supply & Control Voltage Locating Dimple Locating Dimple Locating Dimple
Operating Weight (lbs) 1285 1285 1285Ship Weight (lbs) 1310 1310 1310
¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.² May use fuses or HACR-type circuit breakers of the same size as noted.Note: Always check the S&R plate for electrical data on the unit being installed.
Product Specifications — 10 Tons
6 www.daikinac.com SS-DCH7 SS-DCH7 www.daikinac.com 7
DCH150***3V***A*
DCH150***4V***A*
DCH150***7V***A*
Cooling CapacityTotal, BTU/h 140,000 140,000 140,000Sensible BTU/h 98,000 98,000 98,000EER / IEER 10.6 / 11.8 10.6 / 11.8 10.6 / 11.8Decibels 83 83 83ARI Reference #s 6885866 6885866 6885866
Heating CapacityBTU/h / COP (47° F) 142,000 / 3.2 142,000 / 3.2 142,000 / 3.2BTU/h / COP (17° F) 82,000 / 2.1 82,000 / 2.1 82,000 / 2.1
Evaporator Motor / CoilMotor Type 2-speed Belt Drive 2-speed Belt Drive 2-speed Belt DriveIndoor Nominal CFM 4,000 4,000 4,000Indoor Motor FLA (Cooling) 9.1 4.3 3.5Horsepower - RPM 3.0/1760-1165 3.0/1760-1165 3.0/1760-1165Piston Size (Cooling) 0.094 0.094 0.094Filter Size (in.) (Qty) (4) 20 x 25 x 2 (4) 20 x 25 x 2 (4) 20 x 25 x 2Drain Size (NPT) ¾" ¾" ¾"R-410A Refrigerant Charge Cir #1 & #2 (oz.) 301 / 301 301 / 301 301 / 301Evaporator Coil Face Area (ft²) 14.7 14.7 14.7Rows Deep / Fins per Inch 4/7 4/7 4/7
Belt Drive Evap Fan Data# of Wheels (D x W) (1) 15" x 15" (1) 15" x 15" (1) 15" x 15"Motor Sheave / Blower Sheave VP44 / AK71 VP44 / AK71 VP44 / AK71Belt AX48 AX48 AX48
Condenser Fan / CoilQuantity of condenser Fan Motors 2.0 2.0 2.0Horsepower - RPM ⅓ - 1,075 ⅓ - 1,075 ⅓ - 1,075Fan Diameter / # Fan Blades 22/ 3 22/ 3 22/ 3Outdoor Nominal CFM 8,200 8,200 8,200Face Area (ft²) 35.3 35.3 35.3# Coils / Rows Deep - Fins per Inch 2/3-15 2/3-15 2/3-15Piston Size (Heating) 0.07 0.07 0.07
CompressorQuantity / Type/ Stage 2 / Scroll / 1 2 / Scroll / 1 2 / Scroll / 1Compressor RLA / LRA ea. 22.4 / 149 10.6 / 75 7.7 / 54
Electrical Data / StaticVoltage / Phase / Frequency 208/230-3-60 460-3-60 575-3-60Standard Max Static 1.4" 1.4" 1.4"Outdoor Fan FLA ea. 2.0 0.85 0.67Min. Circuit Ampacity¹ 63.6 / 63.6 29.8 22.2Max. Overcurrent Protection (amps)² 80 / 80 40 25Entrance Power Supply & Entrance Control Voltage Locating Dimple Locating Dimple Locating Dimple
Operating Weight (lbs) 1325 1325 1325Ship Weight (lbs) 1350 1350 1350
¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.² May use fuses or HACR-type circuit breakers of the same size as noted.Note: Always check the S&R plate for electrical data on the unit being installed.
Product Specifications — 12 ½ Tons
8 www.daikinac.com SS-DCH7 SS-DCH7 www.daikinac.com 9
Out
door
Am
bien
t Te
mpe
ratu
re65
7585
9510
511
5En
teri
ng In
door
Wet
Bul
b Te
mpe
ratu
reID
BAi
rflo
w59
6367
7159
6367
7159
6367
7159
6367
7159
6367
7159
6367
71
70
3375
MBh
88.2
91.4
100.
2-
86.1
89.3
97.8
-84
.187
.295
.5-
82.0
85.0
93.2
-77
.980
.888
.5-
72.2
74.8
82.0
-S/
T0.
730.
610.
42-
0.76
0.63
0.44
-0.
780.
650.
45-
0.80
0.67
0.47
-0.
830.
700.
48-
0.84
0.70
0.49
-∆T
1815
12-
1815
12-
1815
12-
1816
12-
1815
12-
1714
11-
kW6.
196.
326.
50-
6.64
6.77
6.98
-7.
037.
177.
39-
7.37
7.53
7.76
-7.
677.
838.
08-
7.92
8.09
8.35
-Hi
PR
234
252
266
-26
228
229
8-
298
321
339
-34
036
638
6-
382
411
434
-42
245
448
0-
Lo P
R10
811
512
6-
114
122
133
-11
912
613
8-
125
133
145
-13
113
915
2-
135
144
157
-
3000
MBh
85.6
88.7
97.2
-83
.686
.795
.0-
81.6
84.6
92.7
-79
.782
.690
.5-
75.7
78.4
85.9
-70
.172
.679
.6-
S/T
0.70
0.58
0.40
-0.
720.
610.
42-
0.74
0.62
0.43
-0.
770.
640.
44-
0.80
0.66
0.46
-0.
800.
670.
46-
∆T18
1612
-19
1612
-19
1612
-19
1612
-18
1612
-17
1511
-kW
6.15
6.27
6.45
-6.
596.
726.
92-
6.98
7.12
7.34
-7.
327.
477.
70-
7.61
7.77
8.01
-7.
868.
038.
28-
Hi P
R23
124
926
3-
260
279
295
-29
531
833
6-
336
362
382
-37
840
743
0-
418
450
475
-Lo
PR
107
114
124
-11
312
013
2-
118
125
137
-12
413
214
4-
130
138
150
-13
414
315
6-
2400
MBh
79.0
81.9
89.7
-77
.280
.087
.7-
75.4
78.1
85.6
-73
.576
.283
.5-
69.8
72.4
79.3
-64
.767
.173
.5-
S/T
0.67
0.56
0.39
-0.
700.
580.
40-
0.72
0.60
0.41
-0.
740.
620.
43-
0.77
0.64
0.44
-0.
770.
650.
45-
∆T20
1813
-21
1814
-21
1814
-21
1814
-21
1813
-19
1713
-kW
6.01
6.13
6.31
-6.
446.
576.
76-
6.81
6.95
7.16
-7.
157.
297.
52-
7.43
7.58
7.82
-7.
677.
838.
08-
Hi P
R22
424
225
5-
252
271
286
-28
630
832
6-
326
351
371
-36
739
541
7-
406
436
461
-Lo
PR
104
111
121
-11
011
712
8-
114
121
133
-12
012
813
9-
126
134
146
-13
013
815
1-
75
3375
MBh
89.7
92.3
100.
010
7.3
87.6
90.2
97.6
104.
885
.588
.095
.310
2.3
83.4
85.9
93.0
99.8
79.3
81.6
88.3
94.8
73.4
75.6
81.8
87.8
S/T
0.83
0.75
0.56
0.36
0.86
0.77
0.58
0.38
0.89
0.79
0.60
0.39
0.91
0.82
0.62
0.40
0.95
0.85
0.64
0.41
0.96
0.86
0.65
0.42
∆T20
1915
1121
1916
1121
1916
1121
1916
1120
1915
1119
1814
10kW
6.24
6.36
6.55
6.75
6.69
6.82
7.03
7.25
7.08
7.23
7.45
7.69
7.43
7.59
7.83
8.07
7.73
7.89
8.14
8.40
7.99
8.16
8.42
8.69
Hi P
R23
625
426
828
026
528
530
131
430
132
434
235
734
336
939
040
738
641
543
945
842
745
948
550
6Lo
PR
109
116
127
135
116
123
134
143
120
128
139
149
126
134
146
156
132
141
154
163
137
145
159
169
3000
MBh
87.1
89.7
97.0
104.
185
.187
.694
.810
1.7
83.0
85.5
92.5
99.3
81.0
83.4
90.3
96.9
77.0
79.2
85.8
92.0
71.3
73.4
79.4
85.3
S/T
0.79
0.71
0.54
0.35
0.82
0.74
0.56
0.36
0.84
0.76
0.57
0.37
0.87
0.78
0.59
0.38
0.90
0.81
0.61
0.39
0.91
0.82
0.62
0.40
∆T21
2016
1121
2016
1121
2016
1122
2016
1121
2016
1120
1815
10kW
6.19
6.32
6.50
6.70
6.64
6.77
6.98
7.19
7.03
7.17
7.39
7.63
7.38
7.53
7.76
8.01
7.67
7.83
8.08
8.34
7.92
8.09
8.35
8.62
Hi P
R23
425
226
627
726
228
229
831
129
832
133
935
434
036
638
640
338
241
143
445
342
245
448
050
1Lo
PR
108
115
126
134
114
122
133
141
119
126
138
147
125
133
145
154
131
139
152
162
135
144
157
167
2400
MBh
80.4
82.7
89.6
96.1
78.5
80.8
87.5
93.9
76.6
78.9
85.4
91.7
74.8
77.0
83.3
89.4
71.0
73.1
79.2
85.0
65.8
67.7
73.3
78.7
S/T
0.77
0.69
0.52
0.33
0.79
0.71
0.54
0.35
0.81
0.73
0.55
0.35
0.84
0.75
0.57
0.37
0.87
0.78
0.59
0.38
0.88
0.79
0.60
0.38
∆T24
2218
1224
2218
1224
2218
1224
2218
1324
2218
1222
2017
12kW
6.06
6.18
6.36
6.55
6.49
6.62
6.82
7.02
6.87
7.01
7.22
7.45
7.20
7.35
7.58
7.82
7.49
7.65
7.88
8.13
7.73
7.90
8.15
8.41
Hi P
R22
724
425
826
925
427
428
930
228
931
132
934
333
035
537
539
137
139
942
143
941
044
146
648
6Lo
PR
105
112
122
130
111
118
129
137
115
123
134
143
121
129
141
150
127
135
147
157
131
140
153
162
IDB:
Ent
erin
g In
door
Dry
Bul
b Te
mpe
ratu
reSh
aded
are
a re
flect
s ACC
A (T
VA) R
ating
Con
ditio
nsHi
gh a
nd lo
w p
ress
ures
are
mea
sure
d at
the
liqui
d an
d su
ction
acc
ess fi
tting
s.De
sign
Supe
rhea
t 7±2
°F, D
esig
n Su
bcoo
ling
12 ±
2 °F
pre
ssur
es m
easu
red
@ th
e su
ction
and
liqu
id se
rvic
e po
rts,
AHR
I 95
test
con
ditio
ns
Expanded Cooling Data — 7½ Tons
8 www.daikinac.com SS-DCH7 SS-DCH7 www.daikinac.com 9
Out
door
Am
bien
t Te
mpe
ratu
re65
7585
9510
511
5En
teri
ng In
door
Wet
Bul
b Te
mpe
ratu
reID
BAi
rflo
w59
6367
7159
6367
7159
6367
7159
6367
7159
6367
7159
6367
71
80
3375
MBh
91.3
93.3
99.7
106.
589
.291
.197
.310
4.1
87.0
88.9
95.0
101.
684
.986
.892
.799
.180
.782
.488
.194
.174
.776
.481
.687
.2S/
T0.
910.
860.
700.
520.
950.
890.
720.
541.
000.
910.
740.
551.
000.
940.
770.
571.
001.
000.
790.
591.
001.
000.
800.
60∆T
2322
1915
2322
1915
2422
1915
2322
1915
2222
1915
2021
1814
kW6.
296.
416.
606.
806.
746.
887.
087.
307.
147.
297.
517.
757.
497.
657.
898.
147.
797.
968.
218.
478.
058.
228.
488.
76Hi
PR
238
257
271
283
268
288
304
317
304
328
346
361
347
373
394
411
390
420
443
462
431
464
490
511
Lo P
R11
011
812
813
711
712
413
614
412
112
914
115
012
713
614
815
813
414
215
516
513
814
716
017
1
3000
MBh
88.6
90.6
96.8
103.
486
.688
.594
.510
1.0
84.5
86.3
92.3
98.6
82.4
84.2
90.0
96.2
78.3
80.0
85.5
91.4
72.5
74.1
79.2
84.7
S/T
0.87
0.82
0.67
0.50
0.90
0.85
0.69
0.52
0.93
0.87
0.71
0.53
0.96
0.90
0.73
0.55
0.99
0.93
0.76
0.57
1.00
0.94
0.76
0.57
∆T24
2320
1624
2320
1624
2320
1624
2320
.016
2423
2016
2221
1915
kW6.
246.
366.
556.
756.
696.
827.
037.
257.
087.
237.
457.
697.
437.
597.
838.
077.
737.
898.
148.
407.
998.
168.
428.
69Hi
PR
236
254
268
280
265
285
301
314
301
324
342
357
343
369
390
407
386
415
439
458
427
459
485
506
Lo P
R10
911
612
713
511
612
313
414
312
012
813
914
912
613
414
715
613
214
115
416
413
714
515
916
9
2400
MBh
81.8
83.6
89.3
95.5
79.9
81.6
87.2
93.2
78.0
79.7
85.1
91.0
76.1
77.8
83.1
88.8
72.3
73.9
78.9
84.4
67.0
68.4
73.1
78.1
S/T
0.84
0.79
0.64
0.48
0.87
0.82
0.67
0.50
0.89
0.84
0.68
0.51
0.92
0.86
0.70
0.53
0.96
0.90
0.73
0.55
0.97
0.91
0.74
0.55
∆T26
2522
1827
2622
1827
2622
1827
2622
1827
2522
1825
2421
16kW
6.10
6.22
6.40
6.60
6.54
6.67
6.87
7.08
6.92
7.06
7.28
7.50
7.26
7.41
7.64
7.88
7.55
7.71
7.95
8.20
7.80
7.96
8.21
8.48
Hi P
R22
924
626
027
125
727
729
230
529
231
533
234
633
335
837
839
537
540
342
644
441
444
547
049
0Lo
PR
106
113
123
131
112
119
130
139
116
124
135
144
122
130
142
151
128
136
149
159
133
141
154
164
85
3375
MBh
92.9
94.7
99.2
105.
890
.792
.596
.810
3.3
88.6
90.3
94.5
100.
986
.488
.192
.298
.482
.183
.787
.693
.576
.077
.581
.286
.6S/
T0.
960.
920.
830.
680.
990.
960.
860.
701.
000.
980.
890.
721.
001.
000.
920.
741.
001.
000.
950.
771.
001.
000.
960.
78∆T
2424
2320
2524
2320
2424
2320
2424
2320
2223
2320
2121
2118
kW6.
336.
466.
656.
856.
796.
937.
147.
367.
197.
347.
577.
817.
557.
717.
958.
207.
858.
028.
278.
548.
128.
298.
558.
83Hi
PR
241
259
274
285
270
291
307
320
307
331
349
364
350
377
398
415
394
424
448
467
435
468
495
516
Lo P
R11
211
913
013
811
812
513
714
612
213
014
215
212
913
714
915
913
514
315
716
713
914
816
217
3
3000
MBh
90.2
91.9
96.3
102.
788
.189
.894
.010
0.3
86.0
87.6
91.8
97.9
83.9
85.5
89.6
95.5
79.7
81.2
85.1
90.8
73.8
75.2
78.8
84.1
S/T
0.91
0.88
0.80
0.65
0.95
0.91
0.82
0.67
0.97
0.94
0.85
0.69
1.00
0.97
0.87
0.71
1.00
1.00
0.91
0.74
1.00
1.00
0.91
0.74
∆T25
2523
2026
2524
2126
2524
2126
2524
2124
2524
2023
2322
19kW
6.29
6.41
6.60
6.80
6.74
6.88
7.08
7.30
7.14
7.29
7.51
7.75
7.49
7.65
7.89
8.14
7.79
7.96
8.21
8.47
8.05
8.22
8.48
8.76
Hi P
R23
825
727
128
326
828
830
431
730
432
834
636
134
737
339
441
139
042
044
346
243
146
449
051
1Lo
PR
110
118
128
137
117
124
136
144
121
129
141
150
127
136
148
158
134
142
155
165
138
147
160
171
2400
MBh
83.2
84.8
88.9
94.8
81.3
82.9
86.8
92.6
79.4
80.9
84.7
90.4
77.4
78.9
82.7
88.2
73.6
75.0
78.5
83.8
68.1
69.4
72.7
77.6
S/T
0.88
0.85
0.77
0.62
0.91
0.88
0.80
0.65
0.94
0.90
0.82
0.66
0.97
0.93
0.84
0.68
1.00
0.97
0.87
0.71
1.00
0.98
0.88
0.71
∆T28
2826
2328
2826
2328
2826
2329
2827
2328
2826
2326
2625
21kW
6.15
6.27
6.45
6.65
6.59
6.72
6.92
7.13
6.97
7.12
7.33
7.56
7.32
7.47
7.70
7.94
7.61
7.77
8.01
8.27
7.86
8.02
8.28
8.55
Hi P
R23
124
926
327
426
027
929
530
829
531
833
535
033
636
238
239
937
840
743
044
841
845
047
549
5Lo
PR
107
114
124
133
113
120
131
140
118
125
137
146
124
131
144
153
130
138
150
160
134
143
156
166
IDB:
Ent
erin
g In
door
Dry
Bul
b Te
mpe
ratu
reSh
aded
are
a re
flect
s AHR
I Rati
ng C
ondi
tions
High
and
low
pre
ssur
es a
re m
easu
red
at th
e liq
uid
and
sucti
on a
cces
s fitti
ngs.
Desig
n Su
perh
eat 7
±2 °F
, Des
ign
Subc
oolin
g 12
±2
°F p
ress
ures
mea
sure
d @
the
sucti
on a
nd li
quid
serv
ice
port
s, A
HRI 9
5 te
st c
ondi
tions
Expanded Cooling Data — 7½ Tons (cont.)
10 www.daikinac.com SS-DCH7 SS-DCH7 www.daikinac.com 11
Expanded Cooling Data — 8½ Tons
Out
door
Am
bien
t Te
mpe
ratu
re65
7585
9510
511
5En
teri
ng In
door
Wet
Bul
b Te
mpe
ratu
reID
BAi
rflo
w59
6367
7159
6367
7159
6367
7159
6367
7159
6367
7159
6367
71
70
3300
MBh
95.1
98.6
108.
0-
92.9
96.3
105.
5-
90.7
94.0
103.
0-
88.5
91.7
100.
5-
84.1
87.1
95.5
-77
.980
.788
.4-
S/T
0.71
0.59
0.41
-0.
730.
610.
43-
0.75
0.63
0.44
-0.
780.
650.
45-
0.81
0.67
0.47
-0.
810.
680.
47-
Delta
T19
1612
-19
1612
-19
1613
-19
1713
-19
1612
-18
1512
-KW
6.93
7.07
7.29
-7.
457.
607.
84-
7.90
8.07
8.32
-8.
308.
488.
75-
8.65
8.83
9.12
-8.
949.
149.
43-
AMPS
11.8
12.0
12.3
-12
.512
.713
.0-
13.3
13.6
13.9
-14
.014
.314
.7-
14.8
15.0
15.4
-15
.515
.816
.2-
HI P
R23
725
526
9-
266
286
302
-30
232
534
3-
344
370
391
-38
741
744
0-
428
460
486
-LO
PR
9910
511
5-
104
111
121
-10
811
512
6-
114
121
132
-11
912
713
9-
123
131
143
-
3200
MBh
95.1
98.6
108.
0-
92.9
96.3
105.
5-
90.7
94.0
103.
0-
88.5
91.7
100.
5-
84.1
87.1
95.5
-77
.980
.788
.4-
S/T
0.71
0.59
0.41
-0.
730.
610.
43-
0.75
0.63
0.44
-0.
780.
650.
45-
0.81
0.67
0.47
-0.
810.
680.
47-
Delta
T19
1713
-20
1713
-20
1713
-20
1713
-19
1713
-18
1612
-KW
6.93
7.07
7.29
-7.
457.
607.
84-
7.90
8.07
8.32
-8.
308.
488.
75-
8.65
8.83
9.12
-8.
949.
149.
43-
AMPS
11.8
12.0
12.3
-12
.512
.713
.0-
13.3
13.6
13.9
-14
.014
.314
.7-
14.8
15.0
15.4
-15
.515
.816
.2-
HI P
R23
725
526
9-
266
286
302
-30
232
534
3-
344
370
391
-38
741
744
0-
428
460
486
-LO
PR
9910
511
5-
104
111
121
-10
811
512
6-
114
121
132
-11
912
713
9-
123
131
143
-
3100
MBh
94.2
97.6
107.
0-
92.0
95.4
104.
5-
89.8
93.1
102.
0-
87.6
90.8
99.5
-83
.286
.394
.5-
77.1
79.9
87.6
-S/
T0.
700.
590.
41-
0.73
0.61
0.42
-0.
750.
620.
43-
0.77
0.64
0.45
-0.
800.
670.
46-
0.81
0.67
0.47
-De
lta T
2017
13-
2017
13-
2017
13-
2017
13-
2017
13-
1816
12-
KW6.
867.
007.
21-
7.37
7.52
7.76
-7.
827.
998.
24-
8.22
8.39
8.66
-8.
558.
749.
02-
8.84
9.04
9.33
-AM
PS11
.711
.912
.2-
12.4
12.6
12.9
-13
.213
.413
.8-
13.9
14.2
14.5
-14
.614
.915
.3-
15.3
15.6
16.0
-HI
PR
234
251
266
-26
228
229
8-
298
321
339
-34
036
538
6-
382
411
434
-42
245
448
0-
LO P
R97
104
113
-10
311
012
0-
107
114
124
-11
212
013
1-
118
125
137
-12
213
014
2-
75
3300
MBh
96.8
99.6
107.
811
5.7
94.5
97.3
105.
311
3.0
92.3
95.0
102.
811
0.3
90.0
92.7
100.
310
7.6
85.5
88.0
95.3
102.
379
.281
.588
.394
.7S/
T0.
810.
720.
550.
350.
840.
750.
570.
360.
860.
770.
580.
370.
880.
790.
600.
380.
920.
820.
620.
400.
930.
830.
630.
40De
lta T
2220
1611
2220
1711
2220
1711
2220
1712
2220
1611
2019
1511
KW6.
987.
137.
357.
587.
507.
667.
908.
157.
978.
148.
398.
678.
378.
558.
839.
128.
728.
919.
209.
509.
029.
219.
519.
83AM
PS11
.912
.112
.412
.712
.612
.813
.113
.513
.413
.714
.014
.414
.114
.414
.815
.214
.915
.215
.616
.015
.615
.916
.316
.8HI
PR
239
257
272
283
268
289
305
318
305
328
347
362
348
374
395
412
391
421
444
463
432
465
491
512
LO P
R10
010
611
612
310
511
212
213
011
011
712
713
611
512
213
414
212
112
814
014
912
513
314
515
4
3200
MBh
96.8
99.6
107.
811
5.7
94.5
97.3
105.
311
3.0
92.3
95.0
102.
811
0.3
90.0
92.7
100.
310
7.6
85.5
88.0
95.3
102.
379
.281
.588
.394
.7S/
T0.
810.
720.
550.
350.
840.
750.
570.
360.
860.
770.
580.
370.
880.
790.
600.
380.
920.
820.
620.
400.
930.
830.
630.
40De
lta T
2221
1712
2321
1712
2321
1712
2321
1712
2321
1712
2119
1611
KW6.
987.
137.
357.
587.
507.
667.
908.
157.
978.
148.
398.
678.
378.
558.
839.
128.
728.
919.
209.
509.
029.
219.
519.
83AM
PS11
.912
.112
.412
.712
.612
.813
.113
.513
.413
.714
.014
.414
.114
.414
.815
.214
.915
.215
.616
.015
.615
.916
.316
.8HI
PR
239
257
272
283
268
289
305
318
305
328
347
362
348
374
395
412
391
421
444
463
432
465
491
512
LO P
R10
010
611
612
310
511
212
213
011
011
712
713
611
512
213
414
212
112
814
014
912
513
314
515
4
3100
MBh
95.8
98.6
106.
711
4.6
93.6
96.3
104.
311
1.9
91.3
94.0
101.
810
9.2
89.1
91.7
99.3
106.
684
.687
.294
.310
1.2
78.4
80.7
87.4
93.8
S/T
0.80
0.71
0.54
0.35
0.83
0.74
0.56
0.36
0.85
0.76
0.57
0.37
0.87
0.78
0.59
0.38
0.91
0.81
0.61
0.40
0.92
0.82
0.62
0.40
Delta
T23
2117
1223
2117
1223
2117
1223
2117
1223
2117
1221
2016
11KW
6.91
7.06
7.27
7.50
7.43
7.58
7.82
8.07
7.88
8.05
8.31
8.57
8.28
8.46
8.73
9.02
8.62
8.81
9.10
9.40
8.92
9.11
9.41
9.72
AMPS
11.8
12.0
12.3
12.6
12.5
12.7
13.0
13.4
13.3
13.5
13.9
14.3
14.0
14.3
14.7
15.1
14.7
15.0
15.4
15.9
15.4
15.7
16.2
16.7
HI P
R23
625
426
828
026
528
530
131
430
132
434
235
734
336
939
040
738
641
543
945
742
645
948
550
5LO
PR
9810
511
412
210
411
112
112
910
811
512
613
411
412
113
214
011
912
713
814
712
313
114
315
2ID
B: E
nter
ing
Indo
or D
ry B
ulb
Tem
pera
ture
Shad
ed a
rea
refle
cts A
CCA
(TVA
)Rati
ng C
ondi
tions
Amps
: Uni
t am
ps (c
omp.
+ ev
apor
ator
+ c
onde
nser
fan
mot
ors)
High
and
low
pre
ssur
es a
re m
easu
red
at th
e liq
uid
and
sucti
on a
cces
s fitti
ngs.
Desig
n Su
perh
eat 7
±2 °F
, Des
ign
Subc
oolin
g 12
±2
°F p
ress
ures
mea
sure
d @
the
sucti
on a
nd li
quid
serv
ice
port
s, A
HRI 9
5 te
st c
ondi
tions
10 www.daikinac.com SS-DCH7 SS-DCH7 www.daikinac.com 11
Expanded Cooling Data — 8½ Tons (cont.)
Out
door
Am
bien
t Te
mpe
ratu
re65
7585
9510
511
5En
teri
ng In
door
Wet
Bul
b Te
mpe
ratu
reID
BAi
rflo
w59
6367
7159
6367
7159
6367
7159
6367
7159
6367
7159
6367
71
70
3300
MBh
95.1
98.6
108.
0-
92.9
96.3
105.
5-
90.7
94.0
103.
0-
88.5
91.7
100.
5-
84.1
87.1
95.5
-77
.980
.788
.4-
S/T
0.71
0.59
0.41
-0.
730.
610.
43-
0.75
0.63
0.44
-0.
780.
650.
45-
0.81
0.67
0.47
-0.
810.
680.
47-
Delta
T19
1612
-19
1612
-19
1613
-19
1713
-19
1612
-18
1512
-KW
6.93
7.07
7.29
-7.
457.
607.
84-
7.90
8.07
8.32
-8.
308.
488.
75-
8.65
8.83
9.12
-8.
949.
149.
43-
AMPS
11.8
12.0
12.3
-12
.512
.713
.0-
13.3
13.6
13.9
-14
.014
.314
.7-
14.8
15.0
15.4
-15
.515
.816
.2-
HI P
R23
725
526
9-
266
286
302
-30
232
534
3-
344
370
391
-38
741
744
0-
428
460
486
-LO
PR
9910
511
5-
104
111
121
-10
811
512
6-
114
121
132
-11
912
713
9-
123
131
143
-
3200
MBh
95.1
98.6
108.
0-
92.9
96.3
105.
5-
90.7
94.0
103.
0-
88.5
91.7
100.
5-
84.1
87.1
95.5
-77
.980
.788
.4-
S/T
0.71
0.59
0.41
-0.
730.
610.
43-
0.75
0.63
0.44
-0.
780.
650.
45-
0.81
0.67
0.47
-0.
810.
680.
47-
Delta
T19
1713
-20
1713
-20
1713
-20
1713
-19
1713
-18
1612
-KW
6.93
7.07
7.29
-7.
457.
607.
84-
7.90
8.07
8.32
-8.
308.
488.
75-
8.65
8.83
9.12
-8.
949.
149.
43-
AMPS
11.8
12.0
12.3
-12
.512
.713
.0-
13.3
13.6
13.9
-14
.014
.314
.7-
14.8
15.0
15.4
-15
.515
.816
.2-
HI P
R23
725
526
9-
266
286
302
-30
232
534
3-
344
370
391
-38
741
744
0-
428
460
486
-LO
PR
9910
511
5-
104
111
121
-10
811
512
6-
114
121
132
-11
912
713
9-
123
131
143
-
3100
MBh
94.2
97.6
107.
0-
92.0
95.4
104.
5-
89.8
93.1
102.
0-
87.6
90.8
99.5
-83
.286
.394
.5-
77.1
79.9
87.6
-S/
T0.
700.
590.
41-
0.73
0.61
0.42
-0.
750.
620.
43-
0.77
0.64
0.45
-0.
800.
670.
46-
0.81
0.67
0.47
-De
lta T
2017
13-
2017
13-
2017
13-
2017
13-
2017
13-
1816
12-
KW6.
867.
007.
21-
7.37
7.52
7.76
-7.
827.
998.
24-
8.22
8.39
8.66
-8.
558.
749.
02-
8.84
9.04
9.33
-AM
PS11
.711
.912
.2-
12.4
12.6
12.9
-13
.213
.413
.8-
13.9
14.2
14.5
-14
.614
.915
.3-
15.3
15.6
16.0
-HI
PR
234
251
266
-26
228
229
8-
298
321
339
-34
036
538
6-
382
411
434
-42
245
448
0-
LO P
R97
104
113
-10
311
012
0-
107
114
124
-11
212
013
1-
118
125
137
-12
213
014
2-
75
3300
MBh
96.8
99.6
107.
811
5.7
94.5
97.3
105.
311
3.0
92.3
95.0
102.
811
0.3
90.0
92.7
100.
310
7.6
85.5
88.0
95.3
102.
379
.281
.588
.394
.7S/
T0.
810.
720.
550.
350.
840.
750.
570.
360.
860.
770.
580.
370.
880.
790.
600.
380.
920.
820.
620.
400.
930.
830.
630.
40De
lta T
2220
1611
2220
1711
2220
1711
2220
1712
2220
1611
2019
1511
KW6.
987.
137.
357.
587.
507.
667.
908.
157.
978.
148.
398.
678.
378.
558.
839.
128.
728.
919.
209.
509.
029.
219.
519.
83AM
PS11
.912
.112
.412
.712
.612
.813
.113
.513
.413
.714
.014
.414
.114
.414
.815
.214
.915
.215
.616
.015
.615
.916
.316
.8HI
PR
239
257
272
283
268
289
305
318
305
328
347
362
348
374
395
412
391
421
444
463
432
465
491
512
LO P
R10
010
611
612
310
511
212
213
011
011
712
713
611
512
213
414
212
112
814
014
912
513
314
515
4
3200
MBh
96.8
99.6
107.
811
5.7
94.5
97.3
105.
311
3.0
92.3
95.0
102.
811
0.3
90.0
92.7
100.
310
7.6
85.5
88.0
95.3
102.
379
.281
.588
.394
.7S/
T0.
810.
720.
550.
350.
840.
750.
570.
360.
860.
770.
580.
370.
880.
790.
600.
380.
920.
820.
620.
400.
930.
830.
630.
40De
lta T
2221
1712
2321
1712
2321
1712
2321
1712
2321
1712
2119
1611
KW6.
987.
137.
357.
587.
507.
667.
908.
157.
978.
148.
398.
678.
378.
558.
839.
128.
728.
919.
209.
509.
029.
219.
519.
83AM
PS11
.912
.112
.412
.712
.612
.813
.113
.513
.413
.714
.014
.414
.114
.414
.815
.214
.915
.215
.616
.015
.615
.916
.316
.8HI
PR
239
257
272
283
268
289
305
318
305
328
347
362
348
374
395
412
391
421
444
463
432
465
491
512
LO P
R10
010
611
612
310
511
212
213
011
011
712
713
611
512
213
414
212
112
814
014
912
513
314
515
4
3100
MBh
95.8
98.6
106.
711
4.6
93.6
96.3
104.
311
1.9
91.3
94.0
101.
810
9.2
89.1
91.7
99.3
106.
684
.687
.294
.310
1.2
78.4
80.7
87.4
93.8
S/T
0.80
0.71
0.54
0.35
0.83
0.74
0.56
0.36
0.85
0.76
0.57
0.37
0.87
0.78
0.59
0.38
0.91
0.81
0.61
0.40
0.92
0.82
0.62
0.40
Delta
T23
2117
1223
2117
1223
2117
1223
2117
1223
2117
1221
2016
11KW
6.91
7.06
7.27
7.50
7.43
7.58
7.82
8.07
7.88
8.05
8.31
8.57
8.28
8.46
8.73
9.02
8.62
8.81
9.10
9.40
8.92
9.11
9.41
9.72
AMPS
11.8
12.0
12.3
12.6
12.5
12.7
13.0
13.4
13.3
13.5
13.9
14.3
14.0
14.3
14.7
15.1
14.7
15.0
15.4
15.9
15.4
15.7
16.2
16.7
HI P
R23
625
426
828
026
528
530
131
430
132
434
235
734
336
939
040
738
641
543
945
742
645
948
550
5LO
PR
9810
511
412
210
411
112
112
910
811
512
613
411
412
113
214
011
912
713
814
712
313
114
315
2ID
B: E
nter
ing
Indo
or D
ry B
ulb
Tem
pera
ture
Shad
ed a
rea
refle
cts A
CCA
(TVA
)Rati
ng C
ondi
tions
Amps
: Uni
t am
ps (c
omp.
+ ev
apor
ator
+ c
onde
nser
fan
mot
ors)
High
and
low
pre
ssur
es a
re m
easu
red
at th
e liq
uid
and
sucti
on a
cces
s fitti
ngs.
Desig
n Su
perh
eat 7
±2 °F
, Des
ign
Subc
oolin
g 12
±2
°F p
ress
ures
mea
sure
d @
the
sucti
on a
nd li
quid
serv
ice
port
s, A
HRI 9
5 te
st c
ondi
tions
Out
door
Am
bien
t Te
mpe
ratu
re65
7585
9510
511
5En
teri
ng In
door
Wet
Bul
b Te
mpe
ratu
reID
BAi
rflo
w59
6367
7159
6367
7159
6367
7159
6367
7159
6367
7159
6367
71
80
3300
MBh
98.5
100.
610
7.5
114.
996
.298
.310
5.0
112.
293
.995
.910
2.5
109.
691
.693
.610
0.0
106.
987
.088
.995
.010
1.6
80.6
82.4
88.0
94.1
S/T
0.88
0.83
0.67
0.50
0.92
0.86
0.70
0.52
0.94
0.88
0.72
0.54
0.97
0.91
0.74
0.55
1.00
0.94
0.77
0.57
1.00
0.95
0.77
0.58
Delta
T24
2320
1625
2420
1625
2420
1625
2421
1624
2320
1622
2219
15KW
7.04
7.18
7.40
7.64
7.56
7.72
7.97
8.22
8.03
8.20
8.46
8.74
8.44
8.62
8.90
9.19
8.79
8.98
9.27
9.58
9.09
9.29
9.59
9.91
AMPS
11.9
12.2
12.5
12.8
12.7
12.9
13.2
13.6
13.5
13.8
14.1
14.6
14.2
14.5
14.9
15.4
15.0
15.3
15.7
16.2
15.7
16.0
16.5
17.0
HI P
R24
226
027
528
627
129
230
832
130
833
235
036
535
137
839
941
639
542
544
946
843
647
049
651
7LO
PR
101
107
117
125
106
113
124
132
111
118
129
137
116
124
135
144
122
130
141
151
126
134
146
156
3200
MBh
98.5
100.
610
7.5
114.
996
.298
.310
5.0
112.
293
.995
.910
2.5
109.
691
.693
.610
0.0
106.
987
.088
.995
.010
1.6
80.6
82.4
88.0
94.1
S/T
0.88
0.83
0.67
0.50
0.92
0.86
0.70
0.52
0.94
0.88
0.72
0.54
0.97
0.91
0.74
0.55
1.00
0.94
0.77
0.57
1.00
0.95
0.77
0.58
Delta
T25
2421
1725
2421
1725
2421
1726
2421
1725
2421
1723
2320
16KW
7.04
7.18
7.40
7.64
7.56
7.72
7.97
8.22
8.03
8.20
8.46
8.74
8.44
8.62
8.90
9.19
8.79
8.98
9.27
9.58
9.09
9.29
9.59
9.91
AMPS
11.9
12.2
12.5
12.8
12.7
12.9
13.2
13.6
13.5
13.8
14.1
14.6
14.2
14.5
14.9
15.4
15.0
15.3
15.7
16.2
15.7
16.0
16.5
17.0
HI P
R24
226
027
528
627
129
230
832
130
833
235
036
535
137
839
941
639
542
544
946
843
647
049
651
7LO
PR
101
107
117
125
106
113
124
132
111
118
129
137
116
124
135
144
122
130
141
151
126
134
146
156
3100
MBh
97.5
99.6
106.
411
3.8
95.2
97.3
104.
011
1.1
93.0
95.0
101.
510
8.5
90.7
92.7
99.0
105.
886
.188
.094
.110
0.5
79.8
81.5
87.1
93.1
S/T
0.87
0.82
0.67
0.50
0.91
0.85
0.69
0.52
0.93
0.87
0.71
0.53
0.96
0.90
0.73
0.55
1.00
0.93
0.76
0.57
1.00
0.94
0.77
0.57
Delta
T25
2421
1726
2521
1726
2521
1726
2522
1725
2421
1724
2320
16KW
6.97
7.11
7.33
7.56
7.49
7.64
7.88
8.13
7.95
8.12
8.37
8.64
8.35
8.53
8.81
9.09
8.70
8.88
9.17
9.48
8.99
9.19
9.49
9.81
AMPS
11.8
12.1
12.3
12.7
12.6
12.8
13.1
13.5
13.4
13.6
14.0
14.4
14.1
14.4
14.8
15.2
14.8
15.1
15.5
16.0
15.5
15.9
16.3
16.8
HI P
R23
825
727
128
326
828
830
431
730
432
734
636
134
737
339
441
139
042
044
346
243
146
449
051
1LO
PR
9910
611
612
310
511
212
213
010
911
612
713
511
512
213
314
212
012
814
014
912
413
214
415
4
85
3300
MBh
100.
210
2.1
107.
011
4.1
97.9
99.8
104.
511
1.5
95.5
97.4
102.
010
8.8
93.2
95.0
99.5
106.
288
.590
.394
.510
0.8
82.0
83.6
87.6
93.4
S/T
0.93
0.89
0.81
0.65
0.96
0.93
0.84
0.68
0.98
0.95
0.86
0.70
1.00
0.98
0.89
0.72
1.00
1.00
0.92
0.75
1.00
1.00
0.93
0.75
Delta
T26
2524
2126
2624
2126
2624
2126
2625
2125
2524
2123
2323
20KW
7.09
7.24
7.46
7.70
7.62
7.78
8.03
8.29
8.09
8.27
8.53
8.81
8.51
8.69
8.97
9.27
8.86
9.05
9.35
9.66
9.16
9.37
9.67
10.0
0AM
PS12
.012
.212
.512
.912
.813
.013
.313
.713
.613
.914
.214
.714
.314
.615
.015
.515
.115
.415
.816
.315
.816
.116
.617
.1HI
PR
244
263
277
289
274
295
311
324
311
335
354
369
355
382
403
420
399
429
453
473
441
474
501
522
LO P
R10
210
811
812
610
811
412
513
311
211
913
013
811
712
513
614
512
313
114
315
212
713
514
815
7
3200
MBh
100.
210
2.1
107.
011
4.1
97.9
99.8
104.
511
1.5
95.5
97.4
102.
010
8.8
93.2
95.0
99.5
106.
288
.590
.394
.510
0.8
82.0
83.6
87.6
93.4
S/T
0.93
0.89
0.81
0.65
0.96
0.93
0.84
0.68
0.98
0.95
0.86
0.70
1.00
0.98
0.89
0.72
1.00
1.00
0.92
0.75
1.00
1.00
0.93
0.75
Delta
T27
2625
2127
2725
2227
2725
2227
2725
2225
2625
2224
2423
20KW
7.09
7.24
7.46
7.70
7.62
7.78
8.03
8.29
8.09
8.27
8.53
8.81
8.51
8.69
8.97
9.27
8.86
9.05
9.35
9.66
9.16
9.37
9.67
10.0
0AM
PS12
.012
.212
.512
.912
.813
.013
.313
.713
.613
.914
.214
.714
.314
.615
.015
.515
.115
.415
.816
.315
.816
.116
.617
.1HI
PR
244
263
277
289
274
295
311
324
311
335
354
369
355
382
403
420
399
429
453
473
441
474
501
522
LO P
R10
210
811
812
610
811
412
513
311
211
913
013
811
712
513
614
512
313
114
315
212
713
514
815
7
3100
MBh
99.2
101.
110
5.9
113.
096
.998
.810
3.4
110.
394
.696
.410
1.0
107.
792
.394
.198
.510
5.1
87.7
89.4
93.6
99.8
81.2
82.8
86.7
92.5
S/T
0.92
0.88
0.80
0.65
0.95
0.92
0.83
0.67
0.97
0.94
0.85
0.69
1.00
0.97
0.88
0.71
1.00
1.00
0.91
0.74
1.00
1.00
0.92
0.74
Delta
T27
2725
2227
2725
2227
2725
2227
2726
2226
2625
2224
2524
20KW
7.02
7.17
7.39
7.62
7.55
7.70
7.95
8.20
8.01
8.18
8.44
8.71
8.42
8.60
8.88
9.17
8.77
8.96
9.25
9.55
9.07
9.27
9.57
9.89
AMPS
11.9
12.1
12.4
12.8
12.6
12.9
13.2
13.6
13.5
13.7
14.1
14.5
14.2
14.5
14.9
15.3
14.9
15.2
15.6
16.1
15.7
16.0
16.4
16.9
HI P
R24
125
927
428
527
029
130
732
030
733
134
936
435
037
739
841
539
442
444
746
743
546
849
451
6LO
PR
100
107
117
124
106
113
123
131
110
117
128
136
116
123
135
143
121
129
141
150
126
134
146
155
IDB:
Ent
erin
g In
door
Dry
Bul
b Te
mpe
ratu
reSh
aded
are
a re
flect
s AHR
I Rati
ng C
ondi
tions
Amps
: Uni
t am
ps (c
omp.
+ ev
apor
ator
+ c
onde
nser
fan
mot
ors)
High
and
low
pre
ssur
es a
re m
easu
red
at th
e liq
uid
and
sucti
on a
cces
s fitti
ngs.
Desig
n Su
perh
eat 7
±2 °F
, Des
ign
Subc
oolin
g 12
±2
°F p
ress
ures
mea
sure
d @
the
sucti
on a
nd li
quid
serv
ice
port
s, A
HRI 9
5 te
st c
ondi
tions
12 www.daikinac.com SS-DCH7 SS-DCH7 www.daikinac.com 13
Out
door
Am
bien
t Te
mpe
ratu
re65
7585
9510
511
5En
teri
ng In
door
Wet
Bul
b Te
mpe
ratu
reID
BAi
rflo
w59
6367
7159
6367
7159
6367
7159
6367
7159
6367
7159
6367
71
70
3938
MBh
114
118
129
-11
111
512
6-
108
112
123
-10
611
012
0-
100
104
114
-93
9610
6-
S/T
0.73
0.61
0.42
-0.
760.
630.
44-
0.78
0.65
0.45
-0.
800.
670.
47-
0.83
0.70
0.48
-0.
840.
700.
49-
∆T19
1713
-20
1713
-20
1713
-20
1713
-20
1713
-18
1612
-kW
8.22
8.37
8.60
-8.
778.
949.
19-
9.25
9.43
9.70
-9.
689.
8710
.16
-10
.04
10.2
410
.55
-10
.36
10.5
610
.88
-Hi
PR
247
266
281
-27
729
831
5-
315
339
358
-35
938
640
8-
404
435
459
-44
648
050
7-
Lo P
R10
511
112
2-
111
118
128
-11
512
213
4-
121
128
140
-12
713
514
7-
131
139
152
-
3500
MBh
110
114
125
-10
811
212
2-
105
109
119
-10
310
611
7-
9810
111
1-
9094
103
-S/
T0.
700.
580.
40-
0.72
0.61
0.42
-0.
740.
620.
43-
0.77
0.64
0.44
-0.
800.
660.
46-
0.80
0.67
0.46
-∆T
20.2
717
.55
13.3
2-
20.5
217
.76
13.4
8-
20.5
417
.78
13.5
0-
20.6
917
.91
13.5
9-
20.4
017
.66
13.4
0-
19.0
516
.49
12.5
2-
kW8.
28.
38.
5-
8.7
8.9
9.1
-9.
29.
49.
6-
9.6
9.8
10.1
-10
.010
.210
.5-
10.3
10.5
10.8
-Hi
PR
245
263
278
-27
429
531
2-
312
336
355
-35
538
340
4-
400
430
454
-44
247
650
2-
Lo P
R10
411
012
0-
110
117
127
-11
412
113
2-
120
127
139
-12
513
314
6-
130
138
151
-
2800
MBh
102
106
116
-99
103
113
-97
101
110
-95
9810
8-
9093
102
-83
8695
-S/
T0.
670.
560.
39-
0.70
0.58
0.40
-0.
720.
600.
41-
0.74
0.62
0.43
-0.
770.
640.
44-
0.77
0.65
0.45
-∆T
2320
15-
2320
15-
2320
15-
2320
15-
2320
15-
2118
14-
kW8
88
-9
99
-9
99
-9
1010
-10
1010
-10
1011
-Hi
PR
237
255
270
-26
628
630
2-
303
326
344
-34
537
139
2-
388
417
441
-42
946
148
7-
Lo P
R10
110
711
7-
106
113
123
-11
011
712
8-
116
123
135
-12
212
914
1-
126
134
146
-
75
3938
MBh
116
119
129
138
113
116
126
135
110
113
123
132
108
111
120
129
102
105
114
122
9597
105
113
S/T
0.83
0.75
0.56
0.4
0.86
0.77
0.58
0.4
0.89
0.79
0.60
0.4
0.91
0.82
0.62
0.4
0.95
0.85
0.64
0.4
0.96
0.86
0.65
0.4
∆T22
.520
.717
.011
.722
.821
.017
.211
.922
.821
.017
.211
.923
.021
.117
.312
.022
.620
.817
.111
.821
.119
.515
.911
.0kW
8.3
8.4
8.7
8.9
8.8
9.0
9.3
9.5
9.3
9.5
9.8
10.1
9.8
9.9
10.2
10.5
10.1
10.3
10.6
10.9
10.4
10.6
11.0
11.3
Hi P
R25
026
928
429
628
030
131
833
231
834
336
237
736
339
041
243
040
843
946
448
445
148
551
253
4Lo
PR
106
113
123
131
112
119
130
138
116
124
135
144
122
130
142
151
128
136
148
158
132
141
154
164
3500
MBh
112
116
125
134
110
113
122
131
107
110
119
128
104
107
116
125
9910
211
111
992
9510
211
0S/
T0.
790.
710.
540.
30.
820.
740.
560.
40.
840.
760.
570.
40.
870.
780.
590.
40.
900.
810.
610.
40.
910.
820.
620.
4∆T
23.4
21.6
17.7
12.2
23.7
21.8
17.9
12.4
23.7
21.9
17.9
12.4
23.9
22.0
18.0
12.5
23.6
21.7
17.8
12.3
22.0
20.3
16.6
11.5
kW8.
28.
48.
68.
88.
88.
99.
29.
59.
39.
49.
710
.09.
79.
910
.210
.510
.010
.210
.510
.910
.410
.610
.911
.2Hi
PR
247
266
281
293
277
298
315
329
315
339
358
374
359
386
408
426
404
435
459
479
446
480
507
529
Lo P
R10
511
112
213
011
111
812
813
711
512
213
414
212
112
814
014
912
713
514
715
713
113
915
216
2
2800
MBh
104
107
115
124
101
104
113
121
9910
211
011
896
9910
711
592
9410
210
985
8795
101
S/T
0.77
0.69
0.52
0.3
0.79
0.71
0.54
0.3
0.81
0.73
0.55
0.4
0.84
0.75
0.57
0.4
0.87
0.78
0.59
0.4
0.88
0.79
0.60
0.4
∆T26
.124
.019
.713
.626
.424
.319
.913
.726
.424
.319
.913
.826
.624
.520
.113
.926
.224
.219
.813
.724
.522
.618
.512
.8kW
8.1
8.2
8.4
8.7
8.6
8.7
9.0
9.2
9.1
9.2
9.5
9.8
9.5
9.7
9.9
10.2
9.8
10.0
10.3
10.6
10.1
10.3
10.6
11.0
Hi P
R24
025
827
228
426
928
930
631
930
632
934
836
234
837
539
641
339
242
244
546
443
346
649
251
3Lo
PR
102
108
118
126
107
114
125
133
112
119
130
138
117
125
136
145
123
131
143
152
127
135
148
157
IDB:
Ent
erin
g In
door
Dry
Bul
b Te
mpe
ratu
reSh
aded
are
a re
flect
s ACC
A (T
VA) R
ating
Con
ditio
nsHi
gh a
nd lo
w p
ress
ures
are
mea
sure
d at
the
liqui
d an
d su
ction
acc
ess fi
tting
s.De
sign
Supe
rhea
t 7±2
°F, D
esig
n Su
bcoo
ling
12 ±
2 °F
pre
ssur
es m
easu
red
@ th
e su
ction
and
liqu
id se
rvic
e po
rts,
AHR
I 95
test
con
ditio
ns
Expanded Cooling Data — 10 Tons
12 www.daikinac.com SS-DCH7 SS-DCH7 www.daikinac.com 13
Out
door
Am
bien
t Te
mpe
ratu
re65
7585
9510
511
5En
teri
ng In
door
Wet
Bul
b Te
mpe
ratu
reID
BAi
rflo
w59
6367
7159
6367
7159
6367
7159
6367
7159
6367
7159
6367
71
80
3938
MBh
118
120
128
137
115
117
125
134
112
115
122
131
109
112
119
128
104
106
114
121
9698
105
112
S/T
0.91
0.86
0.70
0.5
0.95
0.89
0.72
0.5
1.00
0.91
0.74
0.6
1.00
0.94
0.77
0.6
1.00
1.00
0.79
0.6
1.00
1.00
0.80
0.6
∆T25
.124
.120
.916
.725
.424
.421
.216
.926
.224
.421
.216
.925
.624
.621
.417
.124
.324
.821
.116
.822
.523
.019
.715
.7kW
8.34
8.49
8.73
9.0
8.90
9.07
9.32
9.6
9.39
9.57
9.85
10.1
9.83
10.0
210
.31
10.6
10.2
010
.40
10.7
111
.010
.52
10.7
311
.05
11.4
Hi P
R25
227
128
629
928
330
432
133
532
234
636
638
136
639
441
643
441
244
446
848
945
549
051
754
0Lo
PR
107
114
124
132
113
120
131
140
117
125
136
145
123
131
143
152
129
137
150
160
134
142
155
165
3500
MBh
114
117
125
133
112
114
122
130
109
111
119
127
106
109
116
124
101
103
110
118
9496
102
109
S/T
0.87
0.82
0.67
0.50
0.90
0.85
0.69
0.52
0.93
0.87
0.71
0.53
0.96
0.90
0.73
0.55
0.99
0.93
0.76
0.57
1.00
0.94
0.76
0.57
∆T26
.16
25.0
721
.80
17.4
26.4
825
.38
22.0
717
.626
.51
25.4
022
.09
17.6
26.6
925
.58
22.2
417
.826
.32
25.2
221
.93
17.5
24.5
623
.56
20.4
916
.4kW
8.3
8.4
8.7
8.9
8.8
9.0
9.3
9.5
9.3
9.5
9.8
10.1
9.8
9.9
10.2
10.5
10.1
10.3
10.6
11.0
10.4
10.6
11.0
11.3
Hi P
R25
026
928
429
628
030
131
833
231
834
336
237
736
339
041
243
040
843
946
448
445
148
551
253
4Lo
PR
106
113
123
131
112
119
130
138
116
124
135
144
122
130
142
151
128
136
149
158
132
141
154
164
2800
MBh
105
108
115
123
103
105
112
120
101
103
110
117
9810
010
711
493
9510
210
986
8894
101
S/T
0.84
0.79
0.64
0.5
0.87
0.82
0.67
0.5
0.89
0.84
0.68
0.5
0.92
0.86
0.70
0.5
0.96
0.90
0.73
0.5
0.97
0.91
0.74
0.6
∆T29
2824
19.4
2928
2519
.629
2825
19.6
3028
2519
.829
2824
19.5
2726
2318
.2kW
8.1
8.3
8.5
8.7
8.6
8.8
9.1
9.3
9.1
9.3
9.6
9.8
9.5
9.7
10.0
10.3
9.9
10.1
10.4
10.7
10.2
10.4
10.7
11.0
Hi P
R24
226
127
528
727
229
230
932
230
933
235
136
635
237
940
041
739
642
645
046
943
747
149
751
8Lo
PR
103
109
119
127
108
115
126
134
113
120
131
139
118
126
137
146
124
132
144
153
128
136
149
159
85
3938
MBh
120
122
128
136
117
119
125
133
114
116
122
130
111
114
119
127
106
108
113
120
9810
010
511
2S/
T0.
960.
920.
830.
70.
990.
960.
860.
71.
000.
980.
890.
71.
001.
000.
920.
71.
001.
000.
950.
81.
001.
000.
960.
8∆T
26.8
26.3
24.9
21.6
27.1
26.7
25.2
21.8
26.7
26.7
25.2
21.8
26.0
26.5
25.4
22.0
24.7
25.2
25.1
21.7
22.9
23.3
23.4
20.3
kW8.
408.
558.
799.
08.
969.
139.
399.
79.
469.
649.
9210
.29.
9010
.09
10.3
910
.710
.27
10.4
810
.79
11.1
10.5
910
.81
11.1
311
.5Hi
PR
255
274
289
302
286
307
325
339
325
350
369
385
370
398
420
439
416
448
473
493
460
495
523
545
Lo P
R10
811
512
513
311
412
113
214
111
812
613
814
712
413
214
515
413
013
915
116
113
514
415
716
7
3500
MBh
116
118
124
132
114
116
121
129
111
113
118
126
108
110
115
123
103
105
110
117
9597
102
108
S/T
0.91
0.88
0.80
0.65
0.95
0.91
0.82
0.67
0.97
0.94
0.85
0.69
1.00
0.97
0.87
0.71
1.00
1.00
0.91
0.74
1.00
1.00
0.91
0.74
∆T27
.90
27.4
425
.94
22.5
28.2
427
.78
26.2
622
.728
.27
27.8
126
.28
22.8
28.4
028
.00
26.4
722
.926
.98
27.5
026
.10
22.6
24.9
925
.47
24.3
821
.1kW
8.3
8.5
8.7
9.0
8.9
9.1
9.3
9.6
9.4
9.6
9.8
10.1
9.8
10.0
10.3
10.6
10.2
10.4
10.7
11.0
10.5
10.7
11.0
11.4
Hi P
R25
227
128
629
928
330
432
133
532
234
636
638
136
639
441
643
441
244
446
848
945
549
051
754
0Lo
PR
107
114
124
132
113
120
131
140
117
125
136
145
123
131
143
152
129
137
150
160
134
142
155
165
2800
MBh
107
109
115
122
105
107
112
119
102
104
109
116
100
102
107
114
9597
101
108
8890
9410
0S/
T0.
880.
850.
770.
60.
910.
880.
800.
60.
940.
900.
820.
70.
970.
930.
840.
71.
000.
970.
870.
71.
000.
980.
880.
7∆T
31.0
30.5
28.9
25.0
31.4
30.9
29.2
25.3
31.5
30.9
29.2
25.3
31.7
31.2
29.4
25.5
31.1
30.7
29.0
25.1
28.8
28.7
27.1
23.5
kW8.
28.
38.
58.
88.
78.
99.
19.
49.
29.
49.
69.
99.
69.
810
.110
.410
.010
.210
.510
.810
.310
.510
.811
.1Hi
PR
244
263
278
290
274
295
312
325
312
336
355
370
355
382
404
421
400
430
454
474
442
475
502
524
Lo P
R10
411
012
012
810
911
612
713
511
412
113
214
112
012
713
914
812
513
314
515
513
013
815
016
0ID
B: E
nter
ing
Indo
or D
ry B
ulb
Tem
pera
ture
Shad
ed a
rea
refle
cts A
HRI R
ating
Con
ditio
nsHi
gh a
nd lo
w p
ress
ures
are
mea
sure
d at
the
liqui
d an
d su
ction
acc
ess fi
tting
s.De
sign
Supe
rhea
t 7±2
°F, D
esig
n Su
bcoo
ling
12 ±
2 °F
pre
ssur
es m
easu
red
@ th
e su
ction
and
liqu
id se
rvic
e po
rts,
AHR
I 95
test
con
ditio
ns
Expanded Cooling Data — 10 Tons (cont.)
14 www.daikinac.com SS-DCH7 SS-DCH7 www.daikinac.com 15
Expanded Cooling Data — 12½ Tons
Out
door
Am
bien
t Te
mpe
ratu
re65
7585
9510
511
5En
teri
ng In
door
Wet
Bul
b Te
mpe
ratu
reID
BAi
rflo
w59
6367
7159
6367
7159
6367
7159
6367
7159
6367
7159
6367
71
70
4500
MBh
137.
214
2.2
155.
8-
134.
013
8.9
152.
2-
130.
813
5.6
148.
5-
127.
613
2.3
144.
9-
121.
212
5.7
137.
7-
112.
311
6.4
127.
5-
S/T
0.70
0.59
0.41
-0.
730.
610.
42-
0.75
0.62
0.43
-0.
770.
640.
45-
0.80
0.67
0.46
-0.
810.
670.
47-
∆T20
1713
-20
1713
-20
1713
-20
1713
-20
1713
-19
1612
-kW
10.2
710
.49
10.8
2-
11.0
711
.31
11.6
7-
11.7
712
.03
12.4
2-
12.3
912
.67
13.0
9-
12.9
213
.21
13.6
5-
13.3
713
.68
14.1
4-
HI P
R24
726
628
1-
277
298
315
-31
533
935
8-
359
386
408
-40
443
445
9-
446
480
507
-LO
PR
100
107
117
-10
611
312
3-
110
117
128
-11
612
313
5-
121
129
141
-12
613
414
6-
4000
MBh
133.
213
8.1
151.
3-
130.
113
4.8
147.
7-
127.
013
1.6
144.
2-
123.
912
8.4
140.
7-
117.
712
2.0
133.
7-
109.
011
3.0
123.
8-
S/T
0.67
0.56
0.39
-0.
690.
580.
40-
0.71
0.60
0.41
-0.
740.
610.
43-
0.76
0.64
0.44
-0.
770.
640.
45-
∆T21
1813
-21
1814
-21
1814
-21
1814
-21
1814
-19
1713
-kW
10.1
910
.40
10.7
3-
10.9
811
.21
11.5
8-
11.6
711
.93
12.3
2-
12.2
912
.56
12.9
8-
12.8
113
.10
13.5
3-
13.2
613
.56
14.0
2-
HI P
R24
426
327
8-
274
295
312
-31
233
635
5-
355
382
404
-40
043
045
4-
442
475
502
-LO
PR
9910
611
6-
105
112
122
-10
911
612
7-
115
122
133
-12
012
814
0-
124
132
144
-
3500
MBh
122.
912
7.4
139.
6-
120.
112
4.5
136.
4-
117.
212
1.5
133.
1-
114.
411
8.5
129.
9-
108.
611
2.6
123.
4-
100.
610
4.3
114.
3-
S/T
0.65
0.54
0.37
-0.
670.
560.
39-
0.69
0.57
0.40
-0.
710.
590.
41-
0.74
0.61
0.43
-0.
740.
620.
43-
∆T21
1814
-21
1814
-21
1814
-21
1814
-21
1814
-20
1713
-kW
9.94
10.1
510
.47
-10
.71
10.9
411
.29
-11
.38
11.6
312
.01
-11
.98
12.2
512
.65
-12
.49
12.7
713
.19
-12
.92
13.2
213
.66
-HI
PR
237
255
269
-26
628
630
2-
303
326
344
-34
537
139
2-
388
417
441
-42
846
148
7-
LO P
R97
103
112
-10
210
811
8-
106
113
123
-11
111
812
9-
117
124
135
-12
112
814
0-
75
4500
MBh
139.
514
3.6
155.
516
6.9
136.
314
0.3
151.
916
3.0
133.
013
7.0
148.
215
9.1
129.
813
3.6
144.
615
5.2
123.
312
6.9
137.
414
7.5
114.
211
7.6
127.
313
6.6
S/T
0.80
0.71
0.54
0.35
0.83
0.74
0.56
0.36
0.85
0.76
0.57
0.37
0.88
0.78
0.59
0.38
0.91
0.81
0.62
0.40
0.92
0.82
0.62
0.40
∆T23
2117
1223
2117
1223
2117
1223
2118
1223
2117
1221
2016
11kW
10.3
510
.57
10.9
111
.27
11.1
611
.40
11.7
712
.16
11.8
712
.13
12.5
312
.95
12.5
012
.77
13.2
013
.65
13.0
313
.32
13.7
714
.24
13.4
913
.79
14.2
614
.75
HI P
R24
926
828
329
628
030
131
833
231
834
336
237
736
339
041
243
040
843
946
348
345
148
551
253
4LO
PR
102
108
118
126
107
114
125
133
111
119
129
138
117
125
136
145
123
131
143
152
127
135
147
157
4000
MBh
135.
513
9.5
151.
016
2.0
132.
313
6.2
147.
415
8.2
129.
213
3.0
143.
915
4.5
126.
012
9.7
140.
415
0.7
119.
712
3.2
133.
414
3.2
110.
911
4.2
123.
613
2.6
S/T
0.76
0.68
0.52
0.33
0.79
0.71
0.53
0.34
0.81
0.72
0.55
0.35
0.84
0.75
0.57
0.36
0.87
0.78
0.59
0.38
0.88
0.78
0.59
0.38
∆T24
2218
1224
2218
1324
2218
1324
2218
1324
2218
1222
2117
12kW
10.2
710
.49
10.8
211
.17
11.0
711
.31
11.6
712
.06
11.7
712
.03
12.4
312
.84
12.3
912
.67
13.0
913
.53
12.9
213
.21
13.6
514
.12
13.3
813
.68
14.1
414
.62
HI P
R24
726
628
129
327
729
831
532
831
533
935
837
435
938
640
842
540
443
545
947
944
648
050
752
9LO
PR
101
107
117
124
106
113
123
131
110
117
128
137
116
123
135
143
121
129
141
150
126
134
146
155
3500
MBh
125.
012
8.7
139.
314
9.5
122.
112
5.7
136.
114
6.1
119.
212
2.7
132.
814
2.6
116.
311
9.7
129.
613
9.1
110.
511
3.8
123.
113
2.1
102.
310
5.4
114.
112
2.4
S/T
0.73
0.66
0.50
0.32
0.76
0.68
0.52
0.33
0.78
0.70
0.53
0.34
0.81
0.72
0.55
0.35
0.84
0.75
0.57
0.36
0.84
0.75
0.57
0.37
∆T24
2218
1324
2218
1324
2318
1325
2319
1324
2218
1323
2117
12kW
10.0
210
.24
10.5
610
.90
10.8
011
.03
11.3
911
.76
11.4
811
.73
12.1
112
.52
12.0
812
.35
12.7
613
.19
12.5
912
.88
13.3
013
.75
13.0
413
.33
13.7
814
.24
HI P
R24
025
827
228
426
928
930
531
930
632
934
736
234
837
539
641
339
242
244
546
443
346
649
251
3LO
PR
9710
411
312
110
311
012
012
710
711
412
413
211
212
013
113
911
812
513
714
612
213
014
215
1ID
B =
Ente
ring
Indo
or D
ry B
ulb
Tem
pera
ture
Shad
ed a
rea
refle
cts A
CCA
(TVA
) con
ditio
nsDe
sign
Supe
rhea
t 8±3
°F @
the
com
pres
sor s
uctio
n ac
cess
fitti
ng c
onne
ction
.Hi
gh &
low
pre
ssur
es a
re m
easu
red
at th
e liq
uid
& su
ction
serv
ice
port
s.De
sign
Subc
oolin
g, 1
2±3
°F @
liqu
id a
cces
s fitti
ng c
onne
ction
AHR
I 95
test
con
ditio
ns.
Expanded Cooling Data — 12½ Tons
14 www.daikinac.com SS-DCH7 SS-DCH7 www.daikinac.com 15
Expanded Cooling Data — 12½ Tons (cont.)
Out
door
Am
bien
t Te
mpe
ratu
re65
7585
9510
511
5En
teri
ng In
door
Wet
Bul
b Te
mpe
ratu
reID
BAi
rflo
w59
6367
7159
6367
7159
6367
7159
6367
7159
6367
7159
6367
71
80
4500
MBh
142.
014
5.1
155.
016
5.7
138.
714
1.7
151.
416
1.9
135.
413
8.3
147.
815
8.0
132.
113
5.0
144.
215
4.1
125.
512
8.2
137.
014
6.4
116.
211
8.8
126.
913
5.7
S/T
0.88
0.82
0.67
0.50
0.91
0.85
0.69
0.52
0.93
0.87
0.71
0.53
0.96
0.90
0.73
0.55
1.00
0.94
0.76
0.57
1.00
0.94
0.77
0.57
∆T25
2421
1726
2521
1726
2521
1726
2522
1726
2521
1724
2320
16kW
10.4
410
.66
11.0
011
.36
11.2
511
.50
11.8
712
.26
11.9
712
.23
12.6
413
.06
12.6
012
.88
13.3
113
.76
13.1
413
.44
13.8
914
.36
13.6
013
.91
14.3
814
.88
HI P
R25
227
128
629
928
330
432
133
532
234
636
538
136
639
441
643
441
244
346
848
845
549
051
753
9LO
PR
103
109
119
127
108
115
126
134
113
120
131
139
118
126
137
146
124
132
144
153
128
136
149
159
4000
MBh
137.
914
0.9
150.
516
0.9
134.
713
7.6
147.
015
7.1
131.
413
4.3
143.
515
3.4
128.
213
1.0
140.
014
9.7
121.
812
4.5
133.
014
2.2
112.
911
5.3
123.
213
1.7
S/T
0.84
0.78
0.64
0.48
0.87
0.81
0.66
0.49
0.89
0.83
0.68
0.51
0.92
0.86
0.70
0.52
0.95
0.89
0.73
0.54
0.96
0.90
0.73
0.55
∆T26
2522
1827
2622
1827
2622
1827
2623
1827
2622
1825
2421
17kW
10.3
510
.58
10.9
111
.27
11.1
611
.40
11.7
712
.16
11.8
712
.13
12.5
312
.95
12.5
012
.78
13.2
013
.65
13.0
313
.32
13.7
714
.24
13.4
913
.80
14.2
614
.75
HI P
R24
926
828
329
628
030
131
833
231
834
336
237
736
339
041
243
040
843
946
448
345
148
551
253
4LO
PR
102
108
118
126
107
114
125
133
111
119
129
138
117
125
136
145
123
131
143
152
127
135
147
157
3500
MBh
127.
213
0.0
138.
914
8.5
124.
312
7.0
135.
714
5.0
121.
312
4.0
132.
514
1.6
118.
412
0.9
129.
213
8.1
112.
411
4.9
122.
813
1.2
104.
210
6.4
113.
712
1.6
S/T
0.81
0.76
0.62
0.46
0.84
0.78
0.64
0.48
0.86
0.80
0.65
0.49
0.88
0.83
0.67
0.50
0.92
0.86
0.70
0.52
0.93
0.87
0.71
0.53
∆T27
2622
1827
2623
1827
2623
1827
2623
1827
2623
1825
2421
17kW
10.1
010
.32
10.6
510
.99
10.8
811
.12
11.4
811
.86
11.5
711
.83
12.2
212
.62
12.1
812
.45
12.8
713
.30
12.7
012
.98
13.4
213
.87
13.1
513
.44
13.8
914
.37
HI P
R24
226
027
528
727
129
230
932
230
933
235
136
635
237
840
041
739
642
645
046
943
747
049
751
8LO
PR
9810
511
412
210
411
112
112
910
811
512
613
411
412
113
214
011
912
713
814
712
313
114
315
2
85
4500
MBh
144.
514
7.3
154.
216
4.6
141.
114
3.8
150.
716
0.7
137.
814
0.4
147.
115
6.9
134.
413
7.0
143.
515
3.1
127.
713
0.1
136.
314
5.4
118.
312
0.6
126.
313
4.7
S/T
0.92
0.89
0.80
0.65
0.95
0.92
0.83
0.67
0.98
0.94
0.85
0.69
1.00
0.97
0.88
0.71
1.00
1.00
0.91
0.74
1.00
1.00
0.92
0.75
∆T27
2725
2227
2726
2227
2726
2227
2726
2226
2725
2224
2524
21kW
10.5
210
.75
11.0
911
.45
11.3
411
.59
11.9
712
.36
12.0
712
.33
12.7
413
.17
12.7
112
.99
13.4
213
.88
13.2
513
.55
14.0
014
.48
13.7
214
.03
14.5
115
.00
HI P
R25
427
428
930
228
630
732
433
832
534
936
938
537
039
842
043
841
644
847
349
346
049
552
254
5LO
PR
104
110
120
128
109
116
127
135
114
121
132
141
119
127
139
148
125
133
145
155
129
138
150
160
4000
MBh
140.
314
3.0
149.
715
9.8
137.
013
9.7
146.
315
6.0
133.
713
6.3
142.
815
2.3
130.
513
3.0
139.
314
8.6
124.
012
6.4
132.
314
1.2
114.
811
7.0
122.
613
0.8
S/T
0.88
0.85
0.76
0.62
0.91
0.88
0.79
0.64
0.93
0.90
0.81
0.66
0.96
0.93
0.84
0.68
1.00
0.96
0.87
0.70
1.00
0.97
0.88
0.71
∆T28
2826
2329
2827
2329
2827
2329
2827
2328
2826
2326
2625
21kW
10.4
410
.66
11.0
011
.36
11.2
511
.50
11.8
712
.26
11.9
712
.23
12.6
413
.06
12.6
012
.88
13.3
113
.76
13.1
413
.44
13.8
914
.36
13.6
013
.91
14.3
814
.88
HI P
R25
227
128
629
928
330
432
133
532
234
636
538
136
639
441
643
441
244
346
848
845
549
051
753
9LO
PR
103
109
119
127
108
115
126
134
113
120
131
139
118
126
137
146
124
132
144
153
128
136
149
159
3500
MBh
129.
513
2.0
138.
214
7.5
126.
512
8.9
135.
014
4.0
123.
412
5.8
131.
814
0.6
120.
412
2.8
128.
613
7.2
114.
411
6.6
122.
113
0.3
106.
010
8.0
113.
112
0.7
S/T
0.85
0.82
0.74
0.60
0.88
0.85
0.76
0.62
0.90
0.87
0.78
0.63
0.93
0.89
0.81
0.65
0.96
0.93
0.84
0.68
0.97
0.94
0.84
0.69
∆T29
2827
2329
2927
2329
2927
2329
2927
2429
2827
2327
2725
22kW
10.1
810
.40
10.7
311
.08
10.9
711
.21
11.5
711
.96
11.6
711
.93
12.3
212
.73
12.2
812
.56
12.9
713
.41
12.8
113
.09
13.5
313
.99
13.2
613
.56
14.0
114
.49
HI P
R24
426
327
829
027
429
531
232
531
233
635
437
035
538
240
442
140
043
045
447
444
247
550
252
3LO
PR
9910
611
612
310
511
212
213
010
911
612
713
511
512
213
314
212
012
814
014
912
413
214
415
4ID
B =
Ente
ring
Indo
or D
ry B
ulb
Tem
pera
ture
Shad
ed a
rea
refle
cts A
HRI r
ating
con
ditio
nsDe
sign
Supe
rhea
t 8±3
°F @
the
com
pres
sor s
uctio
n ac
cess
fitti
ng c
onne
ction
.Hi
gh &
low
pre
ssur
es a
re m
easu
red
at th
e liq
uid
& su
ction
serv
ice
port
s.De
sign
Subc
oolin
g, 1
2±3
°F @
liqu
id a
cces
s fitti
ng c
onne
ction
AHR
I 95
test
con
ditio
ns.
Expanded Cooling Data — 12½ Tons (cont.)
16 www.daikinac.com SS-DCH7 SS-DCH7 www.daikinac.com 17
DCH090
Outdoor Ambient Temperature
65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10
MBh 113.1 107.1 100.8 94.2 90 87.2 81.0 74.7 56.1 51.8 47.7 45.0 43.3 38.9 34.5 30.1 25.7 21.0
T/R 34.9 33.1 31.1 29.1 27.8 26.9 25.0 23.1 17.3 16.0 14.7 13.9 13.4 12.0 10.6 9.3 7.9 6.5
kW 8.21 8.06 7.90 7.75 7.66 7.59 7.45 7.29 6.65 6.51 6.37 6.29 6.23 6.09 5.95 5.82 5.67 5.54
Amps 29.98 28.23 26.82 25.60 24.9 24.54 23.51 22.62 21.93 21.23 20.51 20.17 19.99 19.29 18.42 17.71 16.84 15.79
COP 4.0 3.9 3.7 3.6 3.4 3.4 3.2 3.0 2.5 2.3 2.2 2.1 2.0 1.9 1.7 1.5 1.3 1.1
HI PR 424 406 390 373 365 358 344 330 316 302 290 283 278 267 257 246 238 229
LO PR 134 124 117 107 101 97 89 80 72 64 56 52 51 43 37 31 27 21
DCH102
Outdoor Ambient Temperature
65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10
MBh 128.2 121.4 114.2 106.8 102 98.8 91.8 84.7 69.2 63.8 58.8 55.5 53.4 48.0 42.5 37.1 31.6 25.9
T/R 34.9 33.1 31.1 29.1 27.8 26.9 25.0 23.1 18.8 17.4 16.0 15.1 14.6 13.1 11.6 10.1 8.6 7.1
kW 9.34 9.17 8.99 8.82 8.72 8.64 8.48 8.30 7.83 7.66 7.50 7.41 7.34 7.17 7.01 6.85 6.68 6.52
Amps 37.57 35.17 33.25 31.57 30.6 30.13 28.71 27.51 26.55 25.60 24.63 24.16 23.91 22.95 21.77 20.79 19.61 18.17
COP 4.0 3.9 3.7 3.5 3.4 3.3 3.2 3.0 2.6 2.4 2.3 2.2 2.1 2.0 1.8 1.6 1.4 1.2
HI PR 419 401 386 369 360 354 340 326 312 298 287 280 275 264 254 244 235 227
LO PR 136 126 118 108 103 99 91 81 73 65 57 53 51 43 37 32 28 22
Above information is for nominal CFM and 70 degree indoor dry bulb. Instantaneous capacity listed. kW = Total system power
High pressure is measured at the liquid line gauge port connection Amps = Outdoor unit amps (comp.+fan)
Low pressure is measured at the compressor suction gauge port connection. Design Super Heat 7°± 2 @ Suction Service Port 47 test condition
Expanded Heating Data
16 www.daikinac.com SS-DCH7 SS-DCH7 www.daikinac.com 17
DCH120
Outdoor Ambient Temperature
65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10
MBh 150.8 142.8 134.4 125.6 120 116.3 108.0 99.6 87.7 81.0 74.6 70.4 67.8 60.8 53.9 47.0 40.1 32.9
T/R 34.9 33.1 31.1 29.1 27.8 26.9 25.0 23.1 20.3 18.7 17.3 16.3 15.7 14.1 12.5 10.9 9.3 7.6
kW 10.70 10.50 10.31 10.11 10.0 9.92 9.73 9.54 8.65 8.47 8.30 8.20 8.13 7.95 7.78 7.61 7.44 7.27
Amps 41.27 38.87 36.93 35.26 34.3 33.81 32.39 31.18 30.22 29.27 28.29 27.82 27.57 26.61 25.42 24.44 23.26 21.81
COP 4.1 4.0 3.8 3.6 3.5 3.4 3.2 3.1 3.0 2.8 2.6 2.5 2.4 2.2 2.0 1.8 1.6 1.3
HI PR 439 421 405 387 378 371 356 342 328 313 301 293 288 277 266 256 246 238
LO PR 133 123 115 106 100 96 89 79 71 64 56 52 50 42 37 31 27 21
DCH150
Outdoor Ambient Temperature
65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10
MBh 178.5 169.0 159.0 148.7 142 137.6 127.8 117.9 104.7 96.6 89.0 84.0 80.9 72.6 64.3 56.1 47.9 39.2
T/R 39.4 37.3 35.1 32.8 31.3 30.3 28.2 26.0 23.1 21.3 19.6 18.5 17.8 16.0 14.2 12.4 10.6 8.6
kW 13.89 13.64 13.39 13.14 13.0 12.89 12.65 12.40 12.36 12.10 11.85 11.70 11.60 11.34 11.09 10.85 10.59 10.34
COP 3.76 3.62 3.48 3.31 3.2 3.12 2.96 2.78 2.48 2.34 2.20 2.10 2.04 1.87 1.70 1.51 1.32 1.11
HI PR 471 452 434 415 405 398 382 367 351 336 322 315 309 297 286 274 264 255
LO PR 129 120 113 103 98 94 86 77 69 62 54 51 49 41 36 30 26 21
Above information is for nominal CFM and 70 degree indoor dry bulb. Instantaneous capacity listed. kW = Total system power
High pressure is measured at the liquid line gauge port connection Amps = Outdoor unit amps (comp.+fan)
Low pressure is measured at the compressor suction gauge port connection. Design Super Heat 7°± 2 @ Suction Service Port 47 test condition
Expanded Heating Data
18 www.daikinac.com SS-DCH7 SS-DCH7 www.daikinac.com 19
Two-Speed Standard Belt Drive at High Speed — Down Shot
ESP(IN W.C.)
Turns Open0 1 2 3 4 5
CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP
0.1 --- --- --- --- --- --- --- --- --- --- --- --- 3617 704 1.07 3293 653 0.840.3 --- --- --- --- --- --- --- --- --- 3541 749 1.15 3179 704 0.88 2757 656 0.660.5 --- --- --- --- --- --- 3447 798 1.23 3049 754 0.94 2606 710 0.71 --- --- ---0.7 --- --- --- 3400 848 1.33 2950 798 1.01 2474 754 0.75 --- --- --- --- --- ---0.9 3303 890 1.41 2871 848 1.11 2408 804 0.82 --- --- --- --- --- --- --- --- ---1.1 2838 897 1.23 --- --- --- --- --- --- --- --- --- --- --- --- --- --- ---
Two-Speed High-Static Belt Drive at High Speed — Down Shot
ESP(IN W.C.)
Turns Open0 1 2 3 4 5
CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP
0.9 --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- 3401 909 1.511.1 --- --- --- --- --- --- --- --- --- --- --- --- 3428 965 1.71 2943 915 1.31.3 --- --- --- --- --- --- --- --- --- 3471 1015 1.9 3012 971 1.5 2423 920 1.121.5 --- --- --- --- --- --- 3722 1063 2.25 3041 1023 1.67 2503 976 1.31 --- --- ---1.7 --- --- --- --- --- --- 3359 1075 2.04 2540 1031 1.5 --- --- --- --- --- ---1.9 --- --- --- 3381 1119 2.22 2890 1080 1.78 --- --- --- --- --- --- --- --- ---2.1 --- --- --- 3089 1129 2.04 --- --- --- --- --- --- --- --- --- --- --- ---
Two-Speed Standard Belt Drive at High Speed — Horizontal
ESP(IN W.C.)
Turns Open0 1 2 3 4 5
CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP
0.1 --- --- --- --- --- --- --- --- --- --- --- --- 3625 701 1.08 3309 660 0.860.3 --- --- --- --- --- --- 3815 797 1.44 3468 747 1.11 3177 703 0.88 2796 663 0.680.5 --- --- --- 3780 841 1.52 3405 803 1.23 3053 753 0.94 2608 709 0.68 2225 665 0.530.7 3687 885 1.6 3327 847 1.29 2968 805 1.02 2423 758 0.73 --- --- --- --- --- ---0.9 3236 891 1.39 2850 852 1.1 2352 807 0.8 --- --- --- --- --- --- --- --- ---1.1 2713 896 1.17 --- --- --- --- --- --- --- --- --- --- --- --- --- --- ---
Two-Speed High-Static Belt Drive at High Speed — Horizontal
ESP(IN W.C.)
Turns Open0 1 2 3 4 5
CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP
0.9 --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- 3447 902 1.541.1 --- --- --- --- --- --- --- --- --- --- --- --- 3398 956 1.65 3006 908 1.311.3 --- --- --- --- --- --- --- --- --- 3486 1008 1.87 2960 962 1.44 --- --- ---1.5 --- --- --- --- --- --- 3514 1057 2.07 2949 1019 1.62 --- --- --- --- --- ---1.7 --- --- --- 3388 1103 2.18 3036 1069 1.84 --- --- --- --- --- --- --- --- ---1.9 --- --- --- 2959 1114 2.0 --- --- --- --- --- --- --- --- --- --- --- ---2.1 --- --- --- 2527 1124 1.86 --- --- --- --- --- --- --- --- --- --- --- ---
Notes • Assume dry coil with filter in place; CFM correction for wet coil = 3%• Any adjustment made to the blower should not cause the motor to draw more than the motor rated RLA. Applications that exceed the above • could require a larger motor. Minimum rated SCFM is 350 per ton.
Airflow Data – 7½ Tons
18 www.daikinac.com SS-DCH7 SS-DCH7 www.daikinac.com 19
Two-Speed Standard Belt Drive at High Speed — Down Shot
ESP(IN W.C.)
Turns Open0 1 2 3 4 5
CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP
0.1 --- --- --- --- --- --- --- --- --- --- --- --- 3467 701 1.04 3143 650 0.810.3 --- --- --- --- --- --- --- --- --- 3391 746 1.12 3029 701 0.85 2607 653 0.630.5 --- --- --- --- --- --- 3297 795 1.20 2899 751 0.91 2456 707 0.68 --- --- ---0.7 --- --- --- 3250 845 1.30 2800 795 0.98 --- --- --- --- --- --- --- --- ---0.9 3153 887 1.38 2721 845 1.08 --- --- --- --- --- --- --- --- --- --- --- ---1.1 2688 894 1.20 --- --- --- --- --- --- --- --- --- --- --- --- --- --- ---
Two-Speed High-Static Belt Drive at High Speed — Down Shot
ESP(IN W.C.)
Turns Open0 1 2 3 4 5
CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP
0.9 --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- 3251 906 1.481.1 --- --- --- --- --- --- --- --- --- --- --- --- 3278 962 1.68 2793 912 1.271.3 --- --- --- --- --- --- --- --- --- 3321 1012 1.87 2862 968 1.47 --- --- ---1.5 --- --- --- --- --- --- 3572 1060 2.22 2891 1020 1.64 --- --- --- --- --- ---1.7 --- --- --- --- --- --- 3209 1072 2.01 --- --- --- --- --- --- --- --- ---1.9 --- --- --- 3231 1116 2.19 2740 1077 1.75 --- --- --- --- --- --- --- --- ---2.1 3256 1156 2.31 2939 1126 2.01 --- --- --- --- --- --- --- --- --- --- --- ---
Two-Speed Standard Belt Drive at High Speed — Horizontal
ESP(IN W.C.)
Turns Open0 1 2 3 4 5
CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP
0.1 --- --- --- --- --- --- --- --- --- --- --- --- 3475 698 1.05 3159 657 0.830.3 --- --- --- --- --- --- 3665 794 1.41 3318 744 1.08 3027 700 0.85 2646 660 0.650.5 --- --- --- 3630 838 1.49 3255 800 1.2 2903 750 0.91 2458 706 0.65 --- --- ---0.7 3537 882 1.57 3177 844 1.26 2818 802 0.99 --- --- --- --- --- --- --- --- ---0.9 3086 888 1.36 2700 849 1.07 --- --- --- --- --- --- --- --- --- --- --- ---1.1 2563 893 1.14 --- --- --- --- --- --- --- --- --- --- --- --- --- --- ---
Two-Speed High-Static Belt Drive at High Speed — Horizontal
ESP(IN W.C.)
Turns Open0 1 2 3 4 5
CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP
0.9 --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- 3297 899 1.511.1 --- --- --- --- --- --- --- --- --- --- --- --- 3248 953 1.62 2856 905 1.281.3 --- --- --- --- --- --- --- --- --- 3336 1005 1.84 2810 959 1.41 --- --- ---1.5 --- --- --- --- --- --- 3364 1054 2.04 2799 1016 1.59 --- --- --- --- --- ---1.7 --- --- --- 3238 1100 2.15 2886 1066 1.81 --- --- --- --- --- --- --- --- ---1.9 3188 1146 2.23 2809 1111 1.97 --- --- --- --- --- --- --- --- --- --- --- ---
Notes • Assume dry coil with filter in place; CFM correction for wet coil = 3%• Any adjustment made to the blower should not cause the motor to draw more than the motor rated RLA. Applications that exceed the above • could require a larger motor. Minimum rated SCFM is 350 per ton.
Airflow Data – 8½ Tons
20 www.daikinac.com SS-DCH7 SS-DCH7 www.daikinac.com 21
Two-Speed Belt Drive at High Speed — Down shot
ESP(IN W.C.)
Turns Open
0 1 2 3 4 5
CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP
0.2 --- --- --- --- --- --- --- --- --- --- --- --- 4629 774 1.76 4269 733 1.42
0.4 --- --- --- --- --- --- --- --- --- 4539 824 1.86 4198 781 1.53 3797 735 1.21
0.6 --- --- --- --- --- --- 4511 868 2.01 4103 829 1.63 3752 787 1.33 3312 745 1.03
0.8 --- --- --- 4445 912 2.14 4144 873 1.81 3695 833 1.45 3180 790 1.07 --- --- ---
1 4418 956 2.3 4073 917 1.92 3661 879 1.55 --- --- --- --- --- --- --- --- ---
1.2 4064 967 2.09 3518 923 1.6 --- --- --- --- --- --- --- --- --- --- --- ---
1.4 3555 972 1.77 --- --- --- --- --- --- --- --- --- --- --- --- --- --- ---
Two-Speed High-Static Belt Drive at High Speed — Down Shot
ESP(IN W.C.)
Turns Open
0 1 2 3 4 5
CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP
0.8 --- --- --- --- --- --- --- --- --- --- 4288 2.63 4681 937 2.38 4206 891 1.91
1.0 --- --- --- --- --- --- --- --- 4273 2.83 3858 2.37 4288 948 2.19 3721 897 1.63
1.2 --- --- --- --- --- --- 4296 3.07 3780 2.52 3327 2.08 3845 954 1.91 --- --- ---
1.4 --- --- 4551 3.81 4257 3.31 3706 2.65 3197 2.17 --- --- --- --- --- --- --- ---
1.6 --- --- 4083 3.42 3842 2.99 3116 2.22 --- --- --- --- --- --- --- --- --- ---
1.8 4230 3.78 3809 3.18 3285 2.66 --- --- --- --- --- --- --- --- --- --- --- ---
2.0 3859 3.45 3322 2.87 --- --- --- --- --- --- --- --- --- --- --- --- --- ---
2.2 3445 3.11 --- --- --- --- --- --- --- --- --- ---
Two-Speed Belt Drive at High Speed — Horizontal
ESP(IN W.C.)
Turns Open
0 1 2 3 4 5
CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP
0.2 --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- 4707 724 1.62
0.4 --- --- --- --- --- --- --- --- --- --- --- --- 4679 774 1.78 4235 730 1.4
0.6 --- --- --- --- --- --- --- --- --- 4595 822 1.91 4223 780 1.55 3679 735 1.16
0.8 --- --- --- --- --- --- 4468 862 1.96 4121 824 1.64 3596 785 1.26 --- --- ---
1 --- --- --- 4349 907 2.06 3990 868 1.72 3463 829 1.31 --- --- --- --- --- ---
1.2 4486 962 2.35 3923 918 1.84 3267 879 1.33 --- --- --- --- --- --- --- --- ---
1.4 3990 967 2.03 --- --- --- --- --- --- --- --- --- --- --- --- --- --- ---
Two-Speed High-Static Belt Drive at High Speed — Horizontal
ESP(IN W.C.)
Turns Open
0 1 2 3 4 5
CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP
0.8 --- --- --- --- --- --- --- --- --- --- 4388 2.74 4681 937 2.38 4206 891 1.91
1.0 --- --- --- --- --- --- --- --- 4374 2.95 4039 2.52 4288 948 2.19 3721 897 1.63
1.2 --- --- --- --- --- --- 4406 3.22 3975 2.67 3451 2.15 3845 954 1.91 --- --- ---
1.4 --- --- --- --- 4320 3.36 3965 2.90 3505 2.38 --- --- --- --- --- --- --- ---
1.6 --- --- 4378 3.61 3493 2.72 3381 2.52 3015 2.06 --- --- --- --- --- --- --- ---
1.8 4440 3.77 3729 3.07 --- --- --- --- --- --- --- --- --- --- --- --- --- ---
2.0 4015 3.38 3080 2.52 --- --- --- --- --- --- --- --- --- --- --- --- --- ---
2.2 3522 2.96 --- --- --- --- --- --- --- --- --- ---
Airflow Data – 10 Tons
20 www.daikinac.com SS-DCH7 SS-DCH7 www.daikinac.com 21
Two-Speed Belt Drive at High Speed — Down shot
ESP (in W.C.)
Turns Open 0 1 2 3 4 5
CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP
0.2 --- --- 5605 2.74 5271 2.32 4915 1.95 4587 1.63 4185 1.320.4 5548 2.96 5202 2.51 4792 2.09 4439 1.73 4073 1.43 3606 1.140.6 5136 2.71 4533 2.14 4315 1.84 3860 1.51 --- --- --- ---0.8 4692 2.51 3931 1.86 3742 1.60 --- --- --- --- --- ---1.0 4166 2.17 --- --- --- --- --- --- --- --- --- ---
Two-Speed High-Static Belt Drive at High Speed — Down Shot
ESP (in W.C.)
Turns Open 0 1 2 3 4 5
CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP
0.8 --- --- --- --- --- --- 5332 3.64 4910 3.09 4479 2.551.0 --- --- 5660 4.52 5271 3.87 4827 3.28 4361 2.74 3932 2.221.2 5582 5.05 5187 4.12 4802 3.52 4332 2.93 3822 2.38 --- ---1.4 5174 4.65 4707 3.69 4260 3.09 3683 2.48 --- --- --- ---1.6 4695 4.23 4208 3.28 3586 2.61 --- --- --- --- --- ---1.8 4187 3.79 3680 2.86 --- --- --- --- --- --- --- ---2.0 3602 3.30 --- --- --- --- --- --- --- --- --- ---
Two-Speed Belt Drive at High Speed — Horizontal
ESP (in W.C.)
Turns Open 0 1 2 3 4 5
CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP
0.2 5230 3.15 4998 2.72 4592 2.24 4474 1.99 4160 1.67 3825 1.400.4 4933 2.92 4619 2.47 4244 2.05 4063 1.79 3722 1.480.6 4602 2,69 4220 2.22 3840 1.84 3652 1.580.8 4265 2.46 3797 1.981.0 3883 2.21
Two-Speed High-Static Belt Drive at High Speed — Horizontal
ESP (in W.C.)
Turns Open 0 1 2 3 4 5
CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP
0.8 5592 4.84 5460 4.22 5178 3.74 4851 3.32 4481 2.84 4115 2.381.0 5436 4.52 5120 3.92 4770 3.41 4445 3.02 4087 2.57 3673 2.131.2 5125 4.22 4780 3.62 4354 3.08 4036 2.73 3670 2.88 --- ---1.4 4795 3.91 4421 3.31 3990 2.81 3602 2.42 --- --- --- ---1.6 4410 3.57 4036 3.00 3652 2.57 --- --- --- --- --- ---1.8 3996 3.22 3593 2.66 --- --- --- --- --- --- --- ---2.0 3760 2.96 --- --- --- --- --- --- --- --- --- ---
Notes• Assume dry coil with filter in place; CFM correction for wet coil = 3%• Any adjustment made to the blower should not cause the motor to draw more than the motor rated RLA. Application • that exceed the above could require a larger motor. Minimum rated SCFM is 350 per ton.
Airflow Data – 12½ Tons
Airflow Pressure Drop of Downflow Economizer for 7.5 to 12.5 Ton Rooftop Units (100% Return Air)SCFM 2000 2500 3000 3500 4000 4500 5000 5500
in. WG 0.02 0.04 0.06 0.09 0.13 0.18 0.23 0.29
22 www.daikinac.com SS-DCH7 SS-DCH7 www.daikinac.com 23
0.00
0.05
0.10
0.15
0.20
0.25
0.30
0.35
0.40
0.45
0.50
0 700600500400300200100
Air Velocity (FPM)
Resi
stan
ce (i
n. w
.g.)
2" Deep
Flanders Pre Pleat M13Air Velocity vs Resistance
(Test Size: 24" x 24" x 2" High Capacity)
High Efficiency MERV 13 Air Filter Option
Crankcase Heater, High Efficiency MERV 13 Air Filter Option
Crankcase Heater Selection TableZP/ZPS… Compressor Diameter Compressor Voltage Crankcase
Heater Watts230V 460V 575V16-31 5.5" 0163R00002S 0163R00031S 0163R00032S 4039-83 6.58/7.3" 0130L00017S 0130L00018S 0130L00019S 70
103-137 9.14” 0130L00020S 0130L00021S 0130L00022S 90
DC* Tonnage Compressor Voltage Crankcase Heater Watts230V 460V 575V
7.5 Ton-12.5 Ton 0130L00017S 0130L00018S 0130L00019S 70
Tonnage: Filter Nominal Size: Part Number: Order QTY:
7.5 16 x 20 x 2 0160L00205 4
7.5(HP), 8.5, 10 16 X 24 X 2 0160L00206 4
12.520 x 20 x 2 0160L00201 4
14 x 20 x 2 0160L00204 2
22 www.daikinac.com SS-DCH7 SS-DCH7 www.daikinac.com 23
Electrical Data - 7½ Tons
Model Number
Electrical Rating
Compressor Circuit 1
Compressor Circuit 2
Outdoor Fan Motor
Indoor Fan Motor
Optional Electric Heat
Optional Powered
Convienience Outlet
Unit Power Supply
RLA LRA RLA LRA QTY HP FLA Type HP FLA Model KW* FLA FLA MCA MOP
DCH090XXX3W 208/230-3-60 13.1 83.1 13.1 83.1 2 0.25 1.42-speed
High Static Belt Drive
2.00 6.0
- - - - 38.4 / 38.4 50 / 50EHK3-16 11.3 / 15.0 31.3 / 36.1 - 77.5 / 83.5 80 / 90EHK3-30 22.5 / 29.9 62.3 / 71.9 - 116 / 128 125 / 150EHK3-45 33.7 / 44.9 93.6 / 108 - 155 / 173 175 / 175
- - - 7.2 / 6.5 45.6 / 44.9 50 / 50EHK3-16 11.3 / 15.0 31.3 / 36.1 7.2 / 6.5 84.7 / 90.0 90 / 90EHK3-30 22.5 / 29.9 62.3 / 71.9 7.2 / 6.5 123 / 135 125 / 150EHK3-45 33.7 / 44.9 93.6 / 108 7.2 / 6.5 163 / 180 175 / 200
DCH090XXX3V 208/230-3-60 13.1 83.1 13.1 83.1 2 0.25 1.4 2-speed Belt Drive 2.00 6.0
- - - - 38.4 / 38.4 50 / 50EHK3-16 11.3 / 15.0 31.3 / 36.1 - 77.5 / 83.5 80 / 90EHK3-30 22.5 / 29.9 62.3 / 71.9 - 116 / 128 125 / 150EHK3-45 33.7 / 44.9 93.6 / 108 - 155 / 173 175 / 175
- - - 7.2 / 6.5 45.6 / 44.9 50 / 50EHK3-16 11.3 / 15.0 31.3 / 36.1 7.2 / 6.5 84.7 / 90.0 90 / 90EHK3-30 22.5 / 29.9 62.3 / 71.9 7.2 / 6.5 123 / 135 125 / 150EHK3-45 33.7 / 44.9 93.6 / 108 7.2 / 6.5 163 / 180 175 / 200
DCH090XXX4W 460-3-60 6.1 41.0 6.1 41.0 2 0.25 0.72-speed
High Static Belt Drive
2.00 2.9
- - - - 18.0 20EHK4-16 15.0 18.0 - 40.6 45EHK4-30 29.9 36.0 - 63.0 70EHK4-45 44.9 54.0 - 85.5 90
- - - 3.3 21.3 25EHK4-16 15.0 18.0 3.3 43.9 45EHK4-30 29.9 36.0 3.3 66.3 70EHK4-45 44.9 54.0 3.3 88.8 90
DCH090XXX4V 460-3-60 6.1 41.0 6.1 41.0 2 0.25 0.7 2-speed Belt Drive 2.00 2.9
- - - - 18.0 20EHK4-16 15.0 18.0 - 40.6 45EHK4-30 29.9 36.0 - 63.0 70EHK4-45 44.9 54.0 - 85.5 90
- - - 3.3 21.3 25EHK4-16 15.0 18.0 3.3 43.9 45EHK4-30 29.9 36.0 3.3 66.3 70EHK4-45 44.9 54.0 3.3 88.8 90
DCH090XXX7W 575-3-60 4.4 33.0 4.4 33.0 2 0.25 0.62-speed
High Static Belt Drive
2.00 2.4
- - - - 13.4 15EHK7-16 15.0 15.1 - 32.2 35EHK7-30 29.9 30.0 - 50.9 60EHK7-45 44.9 45.1 - 69.8 70
- - - 2.6 16.0 20EHK7-16 15.0 15.1 2.6 34.8 35EHK7-30 29.9 30.0 2.6 53.5 60EHK7-45 44.9 45.1 2.6 72.4 80
DCH090XXX7V 575-3-60 4.4 33.0 4.4 33.0 2 0.25 0.6 2-speed Belt Drive 2.00 2.4
- - - - 13.4 15EHK7-16 15.0 15.1 - 32.2 35EHK7-30 29.9 30.0 - 50.9 60EHK7-45 44.9 45.1 - 69.8 70
- - - 2.6 16.0 20EHK7-16 15.0 15.1 2.6 34.8 35EHK7-30 29.9 30.0 2.6 53.5 60EHK7-45 44.9 45.1 2.6 72.4 80
* Elecric Heater kW rating: Rated at 240v for 208-230v units; 480v for 460v units
24 www.daikinac.com SS-DCH7 SS-DCH7 www.daikinac.com 25
Electrical Data - 8½ Tons
Model Number
Electrical Rating
Compressor Circuit 1
Compressor Circuit 2
Outdoor Fan Motor
Indoor Fan Motor
Optional Electric Heat
Optional Powered
Convienience Outlet
Unit Power Supply
RLA LRA RLA LRA QTY HP FLA Type HP FLA Model KW* FLA FLA MCA MOP
DCH102XXX3W 208/230-3-60 14.5 98.0 14.5 98.0 2 0.33 2.32-speed
High Static Belt Drive
2.00 6.0
- - - - 43.2 / 43.2 50 / 50EHK3-16 11.3 / 15.0 31.3 / 36.1 - 82.3 / 88.3 90 / 90EHK3-30 22.5 / 29.9 62.3 / 71.9 - 121 / 133 125 / 150EHK3-45 33.7 / 44.9 93.6 / 108 - 160 / 178 175 / 200
- - - 7.2 / 6.5 50.4 / 49.7 60 / 60EHK3-16 11.3 / 15.0 31.3 / 36.1 7.2 / 6.5 89.5 / 94.8 90 / 100EHK3-30 22.5 / 29.9 62.3 / 71.9 7.2 / 6.5 128 / 140 150 / 150EHK3-45 33.7 / 44.9 93.6 / 108 7.2 / 6.5 167 / 185 175 / 200
DCH102XXX3V 208/230-3-60 14.5 98.0 14.5 98.0 2 0.33 2.3 2-speed Belt Drive 2.00 6.0
- - - - 43.2 / 43.2 50 / 50EHK3-16 11.3 / 15.0 31.3 / 36.1 - 82.3 / 88.3 90 / 90EHK3-30 22.5 / 29.9 62.3 / 71.9 - 121 / 133 125 / 150EHK3-45 33.7 / 44.9 93.6 / 108 - 160 / 178 175 / 200
- - - 7.2 / 6.5 50.4 / 49.7 60 / 60EHK3-16 11.3 / 15.0 31.3 / 36.1 7.2 / 6.5 89.5 / 94.8 90 / 100EHK3-30 22.5 / 29.9 62.3 / 71.9 7.2 / 6.5 128 / 140 150 / 150EHK3-45 33.7 / 44.9 93.6 / 108 7.2 / 6.5 167 / 185 175 / 200
DCH102XXX4W 460-3-60 6.3 55.0 6.3 55.0 2 0.33 1.12-speed
High Static Belt Drive
2.00 2.9
- - - - 19.4 25EHK4-16 15.0 18.0 - 41.9 45EHK4-30 29.9 36.0 - 64.3 70EHK4-45 44.9 54.0 - 86.9 90
- - - 3.3 22.7 25EHK4-16 15.0 18.0 3.3 45.2 50EHK4-30 29.9 36.0 3.3 67.6 70EHK4-45 44.9 54.0 3.3 90.2 100
DCH102XXX4V 460-3-60 6.3 55.0 6.3 55.0 2 0.33 1.1 2-speed Belt Drive 2.00 2.9
- - - - 19.4 25EHK4-16 15.0 18.0 - 41.9 45EHK4-30 29.9 36.0 - 64.3 70EHK4-45 44.9 54.0 - 86.9 90
- - - 3.3 22.7 25EHK4-16 15.0 18.0 3.3 45.2 50EHK4-30 29.9 36.0 3.3 67.6 70EHK4-45 44.9 54.0 3.3 90.2 100
DCH102XXX7W 575-3-60 6.0 41.0 6.0 41.0 2 0.33 0.92-speed
High Static Belt Drive
2.00 2.4
- - - - 17.8 20EHK7-16 15.0 15.1 - 36.6 40EHK7-30 29.9 30.0 - 55.3 60EHK7-45 44.9 45.1 - 74.1 80
- - - 2.6 20.4 25EHK7-16 15.0 15.1 2.6 39.2 40EHK7-30 29.9 30.0 2.6 57.9 60EHK7-45 44.9 45.1 2.6 76.7 80
DCH102XXX7V 575-3-60 6.0 41.0 6.0 41.0 2 0.33 0.9 2-speed Belt Drive 2.00 2.4
- - - - 17.8 20EHK7-16 15.0 15.1 - 36.6 40EHK7-30 29.9 30.0 - 55.3 60EHK7-45 44.9 45.1 - 74.1 80
- - - 2.6 20.4 25EHK7-16 15.0 15.1 2.6 39.2 40EHK7-30 29.9 30.0 2.6 57.9 60EHK7-45 44.9 45.1 2.6 76.7 80
* Elecric Heater kW rating: Rated at 240v for 208-230v units; 480v for 460v units
24 www.daikinac.com SS-DCH7 SS-DCH7 www.daikinac.com 25
Electrical Data - 10 Tons
Model Number
Electrical Rating
Compressor Circuit 1
Compressor Circuit 2
Outdoor Fan Motor
Indoor Fan Motor
Optional Electric Heat
Optional Powered
Convienience Outlet
Unit Power Supply
RLA LRA RLA LRA QTY HP FLA Type HP FLA Model KW* FLA FLA MCA MOP
DCH120XXX3W 208/230-3-60 16.0 110.0 16.0 110.0 2 0.33 2.02-speed
High Static Belt Drive
5.00 14.0
- - - - 53.9 / 53.9 60 / 60EHK3-16 11.3 / 15.0 31.3 / 36.1 - 93.0 / 99.0 100 / 100EHK3-30 22.5 / 29.9 62.3 / 71.9 - 132 / 144 150 / 150EHK3-45 33.7 / 44.9 93.6 / 108 - 171 / 189 175 / 200
- - - 7.2 / 6.5 61.1 / 60.4 70 / 70EHK3-16 11.3 / 15.0 31.3 / 36.1 7.2 / 6.5 100 / 106 100 / 110EHK3-30 22.5 / 29.9 62.3 / 71.9 7.2 / 6.5 139 / 150 150 / 150EHK3-45 33.7 / 44.9 93.6 / 108 7.2 / 6.5 178 / 195 200 / 200
DCH120XXX3V 208/230-3-60 16.0 110.0 16.0 110.0 2 0.33 2.0 2-speed Belt Drive 2.00 6.4
- - - - 46.3 / 46.3 60 / 60EHK3-16 11.3 / 15.0 31.3 / 36.1 - 85.4 / 91.4 90 / 100EHK3-30 22.5 / 29.9 62.3 / 71.9 - 124 / 136 125 / 150EHK3-45 33.7 / 44.9 93.6 / 108 - 163 / 181 175 / 200
- - - 7.2 / 6.5 53.5 / 52.8 60 / 60EHK3-16 11.3 / 15.0 31.3 / 36.1 7.2 / 6.5 92.6 / 97.9 100 / 100EHK3-30 22.5 / 29.9 62.3 / 71.9 7.2 / 6.5 131 / 143 150 / 150EHK3-45 33.7 / 44.9 93.6 / 108 7.2 / 6.5 171 / 188 175 / 200
DCH120XXX4W 460-3-60 7.8 52.0 7.8 52.0 2 0.33 0.92-speed
High Static Belt Drive
5.00 6.6
- - - - 25.8 30EHK4-16 15.0 18.0 - 48.3 50EHK4-30 29.9 36.0 - 70.7 80EHK4-45 44.9 54.0 - 93.3 100
- - - 3.3 29.1 35EHK4-16 15.0 18.0 3.3 51.6 60EHK4-30 29.9 36.0 3.3 74.0 80EHK4-45 44.9 54.0 3.3 96.6 100
DCH120XXX4V 460-3-60 7.8 52.0 7.8 52.0 2 0.33 0.9 2-speed Belt Drive 2.00 3.0
- - - - 22.2 25EHK4-16 15.0 18.0 - 44.7 45EHK4-30 29.9 36.0 - 67.1 70EHK4-45 44.9 54.0 - 89.7 90
- - - 3.3 25.5 30EHK4-16 15.0 18.0 3.3 48.0 50EHK4-30 29.9 36.0 3.3 70.4 80EHK4-45 44.9 54.0 3.3 93.0 100
DCH120XXX7W 575-3-60 5.7 38.9 5.7 38.9 2 0.33 0.72-speed
High Static Belt Drive
5.00 5.2
- - - - 19.4 25EHK7-16 15.0 15.1 - 38.3 40EHK7-30 29.9 30.0 - 57.0 60EHK7-45 44.9 45.1 - 75.8 80
- - - 2.6 22.0 25EHK7-16 15.0 15.1 2.6 40.9 45EHK7-30 29.9 30.0 2.6 59.6 60EHK7-45 44.9 45.1 2.6 78.4 80
DCH120XXX7V 575-3-60 5.7 38.9 5.7 38.9 2 0.33 0.7 2-speed Belt Drive 2.00 2.4
- - - - 16.6 20EHK7-16 15.0 15.1 - 35.5 40EHK7-30 29.9 30.0 - 54.2 60EHK7-45 44.9 45.1 - 73.0 80
- - - 2.6 19.2 20EHK7-16 15.0 15.1 2.6 38.1 40EHK7-30 29.9 30.0 2.6 56.8 60EHK7-45 44.9 45.1 2.6 75.6 80
* Elecric Heater kW rating: Rated at 240v for 208-230v units; 480v for 460v units
26 www.daikinac.com SS-DCH7 SS-DCH7 www.daikinac.com 27
Electrical Data - 12½ Tons
Model Number
Electrical Rating
Compressor Circuit 1
Compressor Circuit 2
Outdoor Fan Motor
Indoor Fan Motor
Optional Electric Heat
Optional Powered
Convienience Outlet
Unit Power Supply
RLA LRA RLA LRA QTY HP FLA Type HP FLA Model KW* FLA FLA MCA MOP
DCH150XXX3W 208/230-3-60 22.4 149.0 22.4 149.0 2 0.33 2.02-speed
High Static Belt Drive
5.00 14.0
- - - - 68.5 / 68.5 90 / 90EHK3-16 11.3 / 15.0 31.3 / 36.1 - 108 / 114 110 / 125EHK3-30 22.5 / 29.9 62.3 / 71.9 - 146 / 158 150 / 175EHK3-45 33.7 / 44.9 93.6 / 108 - 185 / 203 200 / 225
- - - 7.2 / 6.5 75.7 / 75.0 90 / 90EHK3-16 11.3 / 15.0 31.3 / 36.1 7.2 / 6.5 115 / 120 125 / 125EHK3-30 22.5 / 29.9 62.3 / 71.9 7.2 / 6.5 154 / 165 175 / 175EHK3-45 33.7 / 44.9 93.6 / 108 7.2 / 6.5 193 / 210 200 / 225
DCH150XXX3V 208/230-3-60 22.4 149.0 22.4 149.0 2 0.33 2.0 2-speed Belt Drive 3.00 9.1
- - - - 63.6 / 63.6 80 / 80EHK3-16 11.3 / 15.0 31.3 / 36.1 - 103 / 109 110 / 110EHK3-30 22.5 / 29.9 62.3 / 71.9 - 142 / 153 150 / 175EHK3-45 33.7 / 44.9 93.6 / 108 - 181 / 199 200 / 200
- - - 7.2 / 6.5 70.8 / 70.1 90 / 90EHK3-16 11.3 / 15.0 31.3 / 36.1 7.2 / 6.5 110 / 115 110 / 125EHK3-30 22.5 / 29.9 62.3 / 71.9 7.2 / 6.5 149 / 160 150 / 175EHK3-45 33.7 / 44.9 93.6 / 108 7.2 / 6.5 188 / 205 200 / 225
DCH150XXX4W 460-3-60 10.6 75.0 10.6 75.0 2 0.33 0.92-speed
High Static Belt Drive
5.00 6.6
- - - - 32.1 40EHK4-16 15.0 18.0 - 54.7 60EHK4-30 29.9 36.0 - 77.1 80EHK4-45 44.9 54.0 - 99.6 100
- - - 3.3 35.4 45EHK4-16 15.0 18.0 3.3 58.0 60EHK4-30 29.9 36.0 3.3 80.4 90EHK4-45 44.9 54.0 3.3 103 110
DCH150XXX4V 460-3-60 10.6 75.0 10.6 75.0 2 0.33 0.9 2-speed Belt Drive 3.00 4.3
- - - - 29.8 40EHK4-16 15.0 18.0 - 52.4 60EHK4-30 29.9 36.0 - 74.8 80EHK4-45 44.9 54.0 - 97.3 100
- - - 3.3 33.1 40EHK4-16 15.0 18.0 3.3 55.7 60EHK4-30 29.9 36.0 3.3 78.1 80EHK4-45 44.9 54.0 3.3 101 110
DCH150XXX7W 575-3-60 7.7 54.0 7.7 54.0 2 0.33 0.72-speed
High Static Belt Drive
5.00 5.2
- - - - 23.9 30EHK7-16 15.0 15.1 - 42.7 45EHK7-30 29.9 30.0 - 61.4 70EHK7-45 44.9 45.1 - 80.3 90
- - - 2.6 26.5 30EHK7-16 15.0 15.1 2.6 45.3 50EHK7-30 29.9 30.0 2.6 64.0 70EHK7-45 44.9 45.1 2.6 82.9 90
DCH150XXX7V 575-3-60 7.7 54.0 7.7 54.0 2 0.33 0.7 2-speed Belt Drive 3.00 3.5
- - - - 22.2 25EHK7-16 15.0 15.1 - 41.0 45EHK7-30 29.9 30.0 - 59.7 60EHK7-45 44.9 45.1 - 78.6 80
- - - 2.6 24.8 30EHK7-16 15.0 15.1 2.6 43.6 45EHK7-30 29.9 30.0 2.6 62.3 70EHK7-45 44.9 45.1 2.6 81.2 90
* Elecric Heater kW rating: Rated at 240v for 208-230v units; 480v for 460v units
26 www.daikinac.com SS-DCH7 SS-DCH7 www.daikinac.com 27
Model and Heat Kit Usage
RecommendedAirflow Range
DCH090***3V***
EHK3-16 3000-3375 CFM
EHK3-30 3000-3375 CFM
EHK3-45 3000-3375 CFM
Model and Heat Kit Usage
RecommendedAirflow Range
DCH090***4V***
EHK4-16 3000-3375 CFM
EHK4-30 3000-3375 CFM
EHK4-45 3000-3375 CFM
Model and Heat Kit Usage
RecommendedAirflow Range
DCH090***7V***EHK7-16 3000-3375 CFMEHK7-30 3000-3375 CFM
EHK7-45 3000-3375 CFM
kW Correction Factor
kW Correction Factor for 208/230V Units
Supply Voltage 240 230 220 210 208
Correction Factor 1 0.92 0.84 0.77 0.75
kW Correction Factor for 480V Units
Supply Voltage 460 440 430
Correction Factor 0.92 0.84 0.8
For other voltage, use voltage² / 480²
kW Correction Factor for 575V Units
Supply Voltage 560 550 540
Correction Factor 0.95 0.91 0.88
Multiply rated kW by correction factor to get actual kW.
Heat Kit Electrical Data – 7½ Tons
28 www.daikinac.com SS-DCH7 SS-DCH7 www.daikinac.com 29
Model and Heat Kit Usage
RecommendedAirflow Range
(Downshot)
RecommendedAirflow Range
(Horizontal)
DCH102***3V***
EHK3-16 3400 - 3825 CFM 3400 - 3825 CFM
EHK3-30 3400 - 3825 CFM 3400 - 3825 CFM
EHK3-45 3400 - 3825 CFM 3400 - 3825 CFM
Model and Heat Kit Usage
RecommendedAirflow Range
(Downshot)
RecommendedAirflow Range
(Horizontal)
DCH102***4V***
EHK4-16 3400 - 3825 CFM 3400 - 3825 CFM
EHK4-30 3400 - 3825 CFM 3400 - 3825 CFM
EHK4-45 3400 - 3825 CFM 3400 - 3825 CFM
Model and Heat Kit Usage
RecommendedAirflow Range
(Downshot)
RecommendedAirflow Range
(Horizontal)
DCH102***7V***
EHK7-16 3400 - 3825 CFM 3400 - 3825 CFM
EHK7-30 3400 - 3825 CFM 3400 - 3825 CFM
EHK7-45 3400 - 3825 CFM 3400 - 3825 CFM
^ - EHK Heater Kits above require a three-phase power supply
kW Correction Factor
kW Correction Factor for 208/230V Units
Supply Voltage 240 230 220 210 208
Correction Factor 1 0.92 0.84 0.77 0.75
kW Correction Factor for 480V Units
Supply Voltage 460 440 430
Correction Factor 0.92 0.84 0.8
For other voltage, use voltage² / 480²
kW Correction Factor for 575V Units
Supply Voltage 560 550 540
Correction Factor 0.95 0.91 0.88
Multiply rated kW by correction factor to get actual kW.
Heat Kit Electrical Data – 8½ Tons
28 www.daikinac.com SS-DCH7 SS-DCH7 www.daikinac.com 29
Model and Heat Kit Usage
RecommendedAirflow Range
DCH120***3V***EHK3-16 3500 - 4500 CFM
EHK3-30 3500 - 4500 CFMEHK3-45 4000 - 4500 CFM
Model and Heat Kit Usage
RecommendedAirflow Range
DCH120***4V***EHK4-16 3500 - 4500 CFM
EHK4-30 3500 - 4500 CFMEHK4-45 4000 - 4500 CFM
Model and Heat Kit Usage
RecommendedAirflow Range
DCH0120***7V***EHK7-16 3500 - 4500 CFM
EHK7-30 3500 - 4500 CFMEHK7-45 4000 - 4500 CFM
kW Correction Factor
kW Correction Factor for 208/230V Units
Supply Voltage 240 230 220 210 208
Correction Factor 1 0.92 0.84 0.77 0.75
kW Correction Factor for 480V Units
Supply Voltage 460 440 430
Correction Factor 0.92 0.84 0.8
For other voltage, use voltage² / 480²
kW Correction Factor for 575V Units
Supply Voltage 560 550 540
Correction Factor 0.95 0.91 0.88
Multiply rated kW by correction factor to get actual kW.
Heat Kit Electrical Data – 10 Tons
30 www.daikinac.com SS-DCH7 SS-DCH7 www.daikinac.com 31
Model and Heat Kit Usage
RecommendedAirflow Range
DCH150***3V***EHK3-16 4000 - 5600
EHK3-30 4300 - 5600EHK3-45 4500 - 5600
Model and Heat Kit Usage
RecommendedAirflow Range
DCH150***4V***EHK4-16 4000 - 5600
EHK4-30 4300 - 5600EHK4-45 4500 - 5600
Model and Heat Kit Usage
RecommendedAirflow Range
DCH150***7V***EHK7-16 4000 - 5600
EHK7-30 4300 - 5600EHK7-45 4500 - 5600
kW Correction Factor
kW Correction Factor for 208/230V Units
Supply Voltage 240 230 220 210 208
Correction Factor 1 0.92 0.84 0.77 0.75
kW Correction Factor for 480V Units
Supply Voltage 460 440 430
Correction Factor 0.92 0.84 0.8
For other voltage, use voltage² / 480²
kW Correction Factor for 575V Units
Supply Voltage 560 550 540
Correction Factor 0.95 0.91 0.88
Multiply rated kW by correction factor to get actual kW.
Heat Kit Electrical Data – 12½ Tons
30 www.daikinac.com SS-DCH7 SS-DCH7 www.daikinac.com 31
61.7
30
6.15
0
13.8
75
"A"
23.9
30
"B"
6.15
2
36.3
75
7.25
128
.312
42.8
7512
.625
38.8
84
19.6
88
4.47
523.2
86
53.6
86
6.19
2
50.2
39
99.9
80
DC
*090
-150
***
7.5
THR
U 1
2.5
TON
CO
MM
ERC
IAL
ALL
DIM
ENSI
ON
S G
IVEN
AR
E IN
INC
HES
ALL
DIM
ENSI
ON
S AN
D S
PEC
IFIC
ATIO
NS
ARE
SUBJ
ECT
TO C
HAN
GE
WIT
HO
UT
NO
TIC
E
GAS
LIN
E EN
TRAN
CE
CO
MBI
NAT
ION
AI
R IN
LET
(GAS
UN
IT)
FLU
E / V
ENT
OU
TLET
FRO
NT
VIEW
RET
UR
N A
IR S
UPP
LY
SUPP
LY A
IR D
UC
T
CO
ND
ENSA
TE D
RAI
N O
UTL
ET
LIFT
ING
SH
ACKL
E H
OLE
SBO
TH S
IDES
AN
D E
ND
S
RIG
HT
END
VIE
W
DIS
CO
NN
ECT
SWIT
CH
TOP
VIEW
MO
DEL
TO
NN
AGE
"A"
"B"
7.5
TON
CO
MM
ERC
IAL
GAS
, HT
PUM
P, A
IR C
ON
DIT
ION
ER53
.339
20.0
55
8.5
TON
CO
MM
ERC
IAL
GAS
, HT
PUM
P, A
IR C
ON
DIT
ION
ER53
.339
20.0
55
10 T
ON
CO
MM
ERC
IAL
GAS
, HT
PUM
P, A
IR C
ON
DIT
ION
ER53
.339
20.0
55
12.5
TO
N C
OM
MER
CIA
LG
AS, H
T PU
MP,
AIR
CO
ND
ITIO
NER
58.8
3918
.055
Dimensions
12 ½
ton
uses
gril
le
32 www.daikinac.com SS-DCH7 SS-DCH7 www.daikinac.com 33
Electrical Entrance Locations
Low-Voltage Entrance
Dimples Mark Drill Locations
High-Voltage Entrance
10 3/16”
3 3/4”
26 ½”
3¾”
103/16”
Unit Clearances
48"
48"48"
48"
Maintain an adequate clearance around the unit for safety, service, maintenance, and proper unit operation. Leave a clearance of 48" on all sides of the unit for possible compressor removal or service access, and to ensure proper ventilation and condenser airflow. Do not install the unit beneath any obstruction. Install the unit away from all building exhausts to inhibit ingestion of exhaust air into the unit’s fresh-air intake.
32 www.daikinac.com SS-DCH7 SS-DCH7 www.daikinac.com 33
Provisions for forks have been included in the unit base frame. No other fork locations are approved.• Unit must be lifted by the four lifting holes lo-
cated at the base frame corners.• Lifting cables should be attached to the unit with shackles.• The distance between the crane hook and the top of the unit must
not be less than 60”.• Two spreader bars must span over the unit to prevent damage to
the cabinet by the lift cables. Spreader bars must be of sufficient length so that cables do not come in contact with the unit during transport. Remove wood struts mounted beneath unit base frame before setting unit on roof curb. These struts are intended to pro-tect unit base frame from fork lift damage. To remove the struts, extract the sheet metal retainers and pull the struts through the base of the unit. Refer to rigging label on the unit.
Important: If using bottom discharge with roof curb, duct-work should be attached to the curb prior to installing the unit. Duct-work dimensions are shown in Roof Curb Installation Instructions Manual.Refer to the Roof Curb Installation Instructions for proper curb installation. Curbing must be installed in compliance with the National Roofing Contractors Association Manual.Lower unit carefully onto roof mounting curb. While rigging the unit, the center of gravity will cause the condenser end to be lower than the supply air end.Bring condenser end of unit into alignment with the curb. With condenser end of the unit resting on curb member and using curb as a fulcrum, lower opposite end of the unit until entire unit is seated on the curb. When a rectangular cantilever curb is used, take care to center the unit. Check for proper alignment and orientation of supply and return openings with duct.
Corner & Center-of-Gravity Locations
CG
DB
A C
Return
Supply
Evaporator Coil
Compressor 1
Compressor 2
Y
X
30”
49”
Note: These weights are calculated without accessories installed.
Unit Weights 7½-Ton Weights (lbs)
8½-Ton Weights (lbs)
10-Ton Weights (lbs)
12½-Ton Weights (lbs)
Weight A 285 345 345 435
Weight B 285 325 325 345
Weight C 285 320 320 300
Weight D 285 300 300 240
Shipping Weight 1175 1310 1310 1350Operating Weight 1135 1285 1285 1325
Roof Curb Installations – Rigging
34 www.daikinac.com SS-DCH7 SS-DCH7 www.daikinac.com 35
Curb installations must comply with local codes and should follow the established guidelines of the National Roofing Contractors Association.Proper unit installation requires that the roof curb be firmly and permanently attached to the roof structure. Check for adequate fastening method prior to setting the unit on the curb.Full perimeter roof curbs are available from the factory and are shipped unassembled. The installing contractor is responsible for field assembly, squaring, leveling, and mounting on the roof structure. All required hardware necessary for the assembly of the sheet metal curb is included in the curb accessory package.• Determine sufficient structural support before locating and mounting the curb and package unit.• Duct-work must be constructed using industry guidelines. The duct-work must be placed into the roof curb before mounting
the package unit. Our full perimeter curbs include duct connection frames to be assembled with the curb. Cantilevered-type curbs are not available from the factory.
• Contractor furnishes curb insulation, cant strips, flashing, and general roofing material.• Support curbs on parallel sides with roof members. To prevent damage to the unit, the roof members cannot penetrate sup-
ply and return duct openings.Note: The unit and curb accessories are designed to allow vertical duct installation before unit placement. Duct installation after unit placement is not recommended.
See the manual shipped with the roof curb for assembly and installation instructions.
3-D View
15⅜ x 31⅛Supply Opening
14⅝ x 38⅜Return Opening
92¼ 53¼
14
1⅝¾
14
1⅜
3
42
1
6
RCCF
FANC
FANC
RCCF
FANC
FANC
PowerWiring
ThermostatWiring
Power & Low-Voltage Block Locations
Top View
Roof Curb Installations (cont.)
34 www.daikinac.com SS-DCH7 SS-DCH7 www.daikinac.com 35
Wiri
ng is
subj
ect t
o ch
ange
. Alw
ays
refe
r to
the
wiri
ng d
iagr
am o
n th
e un
it fo
r the
mos
t up-
to-d
ate
wiri
ng.
⚠
War
ning
High
Vol
tage
: Di
scon
nect
all
pow
er b
efor
e se
rvic
ing
or in
stal
ling
this
unit.
Mul
tiple
pow
er
sour
ces m
ay b
e pr
esen
t. Fa
ilure
to d
o so
may
caus
e pr
oper
ty d
amag
e, p
erso
nal i
njur
y, or
dea
th.⚡
0140
L033
69-A
BK
CM1
FC1
F C
CM2
PU
FC2
F C
COMP1
T2T3 T1
L3T3
CL2 L1
T2 T1 CC1
YLRD BK
C
TR
24V
COMP 2
T2T3 T1
L3T3
CL2 L1
T2 T1
CC2
YLRD BK
BL
BL
OR
OR
RD
BK
BK
LPS1
322 22222 4
1
2CCR1
322 22222 4
1
2CCR
2
LPS
2HP
S 2
HIG
HEM LO
W
L3T3
CL2 L1
T2 T1 BC 1
L3T3
CL2 L1
T2 T1
BC 2
RD
OR
RD
BK
BK
RD
BK
GR
COL O
RCO
DEBK
-----
------
---- B
LACK
BL --
------
------
- BLU
EBR
-----
------
---- B
ROW
NO
R ---
------
------
ORA
NGE
PU --
------
------
- PUR
PLE
RD --
------
------
- RED
WH
------
------
-- W
HITE
YL --
------
------
- YE
LLO
WPK
-----
------
----
PINK
GR-
------
------
--- G
REEN
GY-
------
------
--- G
REY
WIR
I NG
CODE
F ACT
ORY
WIR
ING
HIG
H VO
LTAG
ELO
W V
OLT
AGE
OPT
IONA
L HI
GH
VOLT
AGE
FIEL
DW
IRIN
GHI
GH
VOLT
AGE
S1S2
RC
GW
1W
2Y1
Y2O
3 2 1
96
8 745
PU
PK
PK
PU
WH
YL
WH
GR
BL
BLBL
WH
YL
PU
YLBR
WH
WH
BL
BL
RD
BL
BK
BK
PU BRBKBR
BL
BL
BL
BL
BL
GR
YL
YL
BL
OR
YL
VM
PU
OR
RD
BK
RD BKRD
YL
HPS1
YL
OR BK
VMR
3 1
BLBL
WH
RD
RD
BL
BL
PLF
PU
PK
PK
WH
GV
RS
ALS
BR
PU
IIC
WH
RD
GR
OR
SEE
NOTE
3
L2
UNUSED COOLHEAT
DIFS
L14 5 6
2 31
ECON
11
8
12
97
10
GR
BL
PU
PU
BR
YL YL
PU
RD
RD
WH
BL
BK
BK
BK
YL
YL
YL
GR
GR
LS
PS
RD
RD
RD
FS
YLPU
BR
IGN
RD OR
YL
WH
WH
BL
BL
BL
BL
BL BL
BL
BLBL
WH
GR
PU
RD
RD
RD
RD
RDYL
PKYL
YLYL
GR
BL
GY
BL
YL
BR
RD
RD
RDW
H
RD
PB
BK BKRDOR
YL
YLG
ND
OR RD
BKRDOR
BLYL
RDBL
RD RD
GR
GR
BR1
BR2
53
21
4NCNO
GR
53
21
4NCNO
YL
BL
GY
YL
BKOR
REPL
ACE
JUM
PER
WIT
HSM
OKE
/FIR
E DE
TECT
OR
SEE
NOTE
5
SEE
NOTE
2
BLW
HOR
BK
BKBK
460OR APPROPRIATEINPUT VOLTAGE
240
RD
SEE
NOTE
6
RDBK
BK
OR
OR
POW
ER S
UPPL
Y46
0-57
5/3/
60SE
E NO
TE 4
46O ORAPPROPRIATE
INPUTVOLTAGE
GR
RD
RD
Wiring Diagram – DCH 7½ – 8½ (230V/ 460V/ 575V, 2-Speed, 3-Phase Belt Drive)
36 www.daikinac.com SS-DCH7 SS-DCH7 www.daikinac.com 37
Wiri
ng is
subj
ect t
o ch
ange
. Alw
ays
refe
r to
the
wiri
ng d
iagr
am o
n th
e un
it fo
r the
mos
t up-
to-d
ate
wiri
ng.
⚠
War
ning
High
Vol
tage
: Di
scon
nect
all
pow
er b
efor
e se
rvic
ing
or in
stal
ling
this
unit.
Mul
tiple
pow
er
sour
ces m
ay b
e pr
esen
t. Fa
ilure
to d
o so
may
caus
e pr
oper
ty d
amag
e, p
erso
nal i
njur
y, or
dea
th.⚡
460-575/3/60 0140L03370-A
460-575/3/60SUPPLY VOLTAGE
CC1
L2
T3
COMP1 T2
FCM1
L1
CC1T1
C
CC1
T3
L3T2
SEE UNIT RATING PLATE FOR TYPE AND SIZE
COMPONENT LEGEND
OF OVER CURRENT PROTECTION
ALSBCBRCBCCCCRCMCOMPEMFFCFSGNDGVHPSIBRIICIGNLPSLSPLFPSRSTB1TRVMVMR
OPTIONAL HIGHVOLTAGE
HIGH VOLTAGE
FIELD WIRING
OR ORANGE
YL YELLOW
PU PURPLE
GR GREEN
PK PINK
RD REDWH WHITE
LOW VOLTAGE
BK BLACKWIRE CODE
BR BROWNBL BLUE
LINE VOLTAGE
FACTORY WIRING
LOW VOLTAGE
AUXILLARY LIMIT SWITCHBLOWER CONTACTORBLOWER RELAYCIRCUIT BREAKERCOMPRESSOR CONTACTORCOMPRESSOR CONTACTOR RELAYCONDENSER MOTORCOMPRESSOREVAPORATOR MOTORFUSEFAN CAPACITORFLAME SENSOREQUIPMENT GROUNDGAS VALVEHIGH PRESSURE SWITCHINDOOR BLOWER RELAYINTEGRATED IGNITION CONTROLIGNITORLOW PRESSURE SWITCHLIMIT SWITCHFEMALE PLUG/CONNECTORPRESSURE SWITCHROLLOUT SWITCHTERMINAL BLOCK (24V SIGNAL)TRANSFORMERVENT MOTORVENT MOTOR RELAY
3. L1 AND L2 ON IIC CONTROL IS 24V INPUT.
4. USE COPPER CONDUCTORS ONLY.++ USE NEC CLASS 2 WIRE.
5. FOR TWO STAGE OPERATION REMOVEW1 TO W2 JUMPER WIRE
2. ACCESSORY ECONOMIZER PLUG ADJACENTTO BLOWER HOUSING IN RETURN AIRCOMPARTMENT. REMOVE MALE PLUG ANDATTACH FEMALE PLUG TO THE ECONOMIZERACCESSORY.
1. REPLACEMENT WIRE MUST BE THE SAMESIZE AND TYPE OF INSULATION AS ORIGINAL.(USE COPPER CONDUCTOR ONLY).
NOTES
YL /PK YELLOW WITHPINK STRIP
BL /PK BLUE WITHPINK STRIP
RD
W1
STAT
Y1
Y2
WH
C
G
YL
Y2
2 STAGE COOLING
R
C
G
R
W1
TB1
PK
GR
Y1
BL
W2BRW2NOTE 5
24V
TB1
BC1IIC
VMR
FSIGN
NOTE 3L2
RSGV
PLF
NOTE 2
LS
H C
D1
FSF
5
4
L1 NOTE 3
ALS
ECON
3
6
9
IIC
7
CCR2
321
9 6
87 4
5
INSTALLER/SERVICEMAN
THE STATUS LIGHT ON THE FURNACE CONTROL MAY BE USED AS A GUIDE TOTROUBLESHOOTING THIS APPLIANCE. STATUS LIGHT CODES ARE AS FOLLOWS:
FALSE FLAME SENSED
OPEN LIMIT SWITCH
WITHOUT INDUCER ONPRESSURE SWITCH CLOSED
PRESSURE SWITCHOPEN
NORMAL OPERATION
3 BLINKS
6 BLINKS
4 BLINKS
5 BLINKSCOMPRESSOROUTPUT DELAY
OFF
ON
1 BLINK
2 BLINKS
STATUS LIGHT
OPEN AUX. LIMITSWITCH
IGNITION FAILURE
OPEN ROLLOUTSWITCH
NO POWER ORINTERNAL CONTROL
EQUIPMENT STATUS
CHECKPRESSURE SWITCH
MAIN LIMIT OPENBAD SWITCH
STICKING GAS VALVE3 MIN. COMP.
ANTI-CYCLE TIMER
CHECKPRESSURE SWITCH
GAS PRESSURE
FLAME ROLLOUT
AUX. LIMIT OPEN
FLAME SENSOR
BAD SWITCH
GAS VALVE
GAS FLOW
CHECK INPUT POWERCHECK FUSE ON CONTROL
REPLACE CONTROL
------
CHECK
TR
1
2
6. MOVE WIRE(S) TO APPROPRIATE INPUTVOLTAGE TERMINAL ON TRANSFORMER.
FC1
LPS1 HPS14 2 CC1
4 2 CC2CCR2
CCR1
HC
BC2
2
5
4BR1
11
CCR11210
BR1
BR2
2
5
4BR2
HPS2 LPS2
SEE NOTE 6
8PS
C
THERMOSTATFIELD WIRINGTHERMOSTATFIELD WIRING
TO THERMOSTAT ++
BC1
BC2
BC2
BC1
BC1
BC2LOW SPEED
HIGH SPEED
EM
T1 T2
T3
CC2
C
T1 CC2
CM2F
T2
COMP2
T3
CC2
FC2
460V ORAPPROPRIATE
INPUTVOLTAGE
VMR
24
C
VM
RO G CY1W1W2 Y2S2S1 RO G CY1W1W2S2S1
Wiring Diagram – DCH 7½ – 8½ (230V/ 460V/ 575V, 2-Speed, 3-Phase Belt Drive)
36 www.daikinac.com SS-DCH7 SS-DCH7 www.daikinac.com 37
Wiri
ng is
subj
ect t
o ch
ange
. Alw
ays
refe
r to
the
wiri
ng d
iagr
am o
n th
e un
it fo
r the
mos
t up-
to-d
ate
wiri
ng.
⚠
War
ning
High
Vol
tage
: Di
scon
nect
all
pow
er b
efor
e se
rvic
ing
or in
stal
ling
this
unit.
Mul
tiple
pow
er
sour
ces m
ay b
e pr
esen
t. Fa
ilure
to d
o so
may
caus
e pr
oper
ty d
amag
e, p
erso
nal i
njur
y, or
dea
th.⚡
0140
L025
77-A
BK
CM1
FC1
F CT1T2
L1L2
CM2
PU
FC2
F C
RDRD
CMC
PU
PU
COMP1
T2T3 T1
L3T3
CL2 L1
T2 T1 CC1
YLRD BK
C460575
TR
24V
COMP 2
T2T3 T1
L3T3
CL2 L1
T2 T1
CC2
YLRD BK
BL
BL
BL
BL
BK
BL
BK
PB
RD
RD
RD
BK BK
BK
BK
LPS1
HPS1
322 22222 4
1
2CCR1
YL
322 22222 4
1
2 CCR
2
LPS
2HP
S 2
HIG
HEM LO
W
T1
L3
T2
L1
T3
L2
CB1
HIG
HSP
EED
T1
L3
T2
L1
T3
L2
CB2
LOW
SPEE
D
L3T3
CL2 L1
T2 T1
BC 1
L3T3
CL2 L1
T2 T1
BC 2
RD
OR
RD
BK
BK
RD
BK
GR
GR
6
28 5
7
39
4 1
PLF 1WH
GND
COLO
RC O
D EBK
-----
------
---- B
LACK
BL --
------
------
- BLU
EBR
-----
------
---- B
ROW
NO
R ---
------
------
ORA
NGE
PU --
------
------
- PUR
PLE
RD --
------
------
- RED
WH
-----
------
--- W
HIT
EYL
-----
------
---- Y
ELLO
WPK
-----
------
---- P
INK
GR-
------
------
--- G
REEN
WIR
ING
CODE
FACT
ORY
WIR
ING
HIG
H VO
LTAG
ELO
W V
OLT
AGE
OPT
IONA
L HI
GH
VOLT
AGE
FIEL
DW
IRIN
GHI
GH
VOLT
AGE
53
2 14
NC
NO
S1S2
RC
GW
1W
2Y1
Y2O
RD
BL
BLPK
DFT1 DFT2
RVC1 RVC2
COM
R
NCNO
UP
C
K1
SPEE
DK1
M1
XFM
R-C
EBTD
R
XFM
R-R
M2
3 2 1
96
8 745
RD
WH
PU
PU
PU
PUPK
PK
YL
PU
WH
YL
YL
YL
BR
WH
GR
GRG
R
GR
BL
BL
BL
RD
HVDR DF
2
C R
DC
O O R
LVDR
Y DFT
W2
DF1
RD
RD
YL
BLYL
PU
PUPU
PU
YL
BRBR
RD
BR
BR
BLBR
BL
SSHR
OR
BL
OR O
R
RD
RDRD
RD
WH
WH
WH
PU
YL YL
BK BK
BKBK
BLBL
BL
BL
BL
OR
OR
OR
OR
RD
BL
BK
BKBK
BK
PU BRBKBR
YL
YL
BL
BL
BL
YL
RDRD
GR
GR
GR
GR
YLYLYL
YL
BL
OR RD BK
OR
OR
OR
RD
RD
RD
BL
BL
BLBR
RDRD
BL
YLO
RO
R
YL
OR
BLBL
BR1
BR2
BR3
RDW
H
RDRD
RDO
R
WH
G
RD
OR
24V
460
575
C
ORRD
PK
BL
TR
53
21
4NCNO
DRBL
RD
RD5
3
21
4NCNO
GR
53
21
4NCNO 5
3
21
4NCNO
YL
OR BK
BL
REPL
ACE
JUM
PER
WIT
HSM
OKE
/FIR
E DE
TECT
OR
BL
BL
BL
BL BL
YL YL
GY
YL
BLGY YL
SEE
NOTE
4
SEE
NOTE
5
SEE
NOTE
5
SEE
NOTE
3
GR
POW
ER S
UPPL
Y20
8-24
0/46
0/57
5/3/
60SE
E NO
TE 2
PLF
2
208
240
208240
BKBK
BK
YL
YLYL
RDRD
Wiring Diagram – DCH 10 – 12½ (230V/ 460V/ 575V, 2-Speed, 3-Phase Belt Drive)
38 www.daikinac.com SS-DCH7 SS-DCH7 www.daikinac.com 39
Wiri
ng is
subj
ect t
o ch
ange
. Alw
ays
refe
r to
the
wiri
ng d
iagr
am o
n th
e un
it fo
r the
mos
t up-
to-d
ate
wiri
ng.
⚠
War
ning
High
Vol
tage
: Di
scon
nect
all
pow
er b
efor
e se
rvic
ing
or in
stal
ling
this
unit.
Mul
tiple
pow
er
sour
ces m
ay b
e pr
esen
t. Fa
ilure
to d
o so
may
caus
e pr
oper
ty d
amag
e, p
erso
nal i
njur
y, or
dea
th.⚡
R
BC2
R
HVDR
RVC2
SEE UNIT RATING PLATE FOR TYPE AND SIZE
5
OF OVER CURRENT PROTECTION
4
BLOWER CONTACTOR
COMPRESSOR CONTACTORCONDENSER MOTORCONDENSER MOTOR CONTACTORCOMPRESSORDEFROST CONTROLDEFROST THERMOSTATECONOMIZERELECTRONIC BLOWER TIME DELAYEVAPORATOR MOTOR RELAYRELAYEVAPORATOR MOTORFAN CAPACITOREQUPIMENT GROUNDHIGH PRESSURE SWITCHHIGH VOLTAGE DEFROST RELAYLOW PRESSURE SWITCHLOW VOLTAGE DEFROST RELAYLOW VOLTAGE JUNCTION BOXPOWER DISTRIBUTION BLOCKFEMALE PLUG / CONNECTORREVERSING VAVLE COILTERMINAL BLOCK (24V SIGNAL)TRANSFORMER
LVDR
W2R
DFT2
C
BC
CCCMCMCCOMPDCDFTECONEBTDEMRREMFCGNDHPSHVDRLPSLVDRLVJBPBPLFRVCTB1TR
6
COMPONENT LEGEND
R
R
G
NOTES:
1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY.2. USE COPPER CONDUCTORS ONLY ++ USE N.E.C. CLASS 2 WIRE3. ECONOMIZER PLUG LOCATED IN THE RETURN AIR COMPARTMENT. REMOVE MALE PLUG AND ATTACH FEMALE PLUG TO THE ECONOMIZER ACCESSORY.4. FOR TWO STAGE OPERATION REMOVE W1 TO W2 JUMPER WIRE.
EBTDR
CC1HPS1
LPS1
LOW VOLTAGE
LINE VOLTAGE
FIELD WIRING
LOW VOLTAGE OPTIONAL
HIGH VOLTAGE
FACTORY WIRING
HIGH VOLTAGE
CC2
GR GREEN
WIRE CODE
BL BLUE
PU PURPLEPK PINK
WH WHITE
BK BLACK
RD RED
BR BROWN
OR ORANGE
YL YELLOWYL/PK YELLOW WITH PINK STRIPBL/PK BLUE WITH PINK STRIP
CMC
CMCCM2
T2
CC2
T3
T1COMP2
CC2T1
CC2T2
CMC
CC1
L2
T3
COMP1
F
SUPPLY VOLTAGE
CM1
L1
CC1T1
C
CC1
L3208-240/440/575/3/60
T2
TR24V
8
7
9
ORO O
BL
Y1
GR
PK
TB1
W1
RG
C
R
2 STAGE COOLING
YL
G
C
WH
Y2
Y1
STAT
W1
RD
THERMOSTATFIELD WIRING
W2 BR W2
NONC
PLF29
7
8 56
4
32
1
SEE NOTE 3
O
SSHR SECOND STAGE HEATER RELAY
BC2
EM
CB2BC2
HIGH SPEED
LOW SPEEDCB2
BC1CB1
BC1
BC1
BR1
BR1
BR2BR3
BR2
BR3
CCR1
CCR2
LPS2HPS2
CB1
EBTDR
BLOWER RELAYCIRCUIT BREAKERCOMPRESSOR CONTACTOR RELAY
BRCBCCR
FC
BC2CB2
BC1CB1
4
5
2
4
5
24
5
2
DFT1R
R EBTDR
BC2
R
HVDR
Y
SEE UNIT RATING PLATE FOR TYPE AND SIZE
5
OF OVER CURRENT PROTECTION
4
BLOWER CONTACTOR
COMPRESSOR CONTACTORCONDENSER MOTORCONDENSER MOTOR CONTACTORCOMPRESSORDEFROST CONTROLDEFROST THERMOSTATECONOMIZERELECTRONIC BLOWER TIME DELAYEVAPORATOR MOTOR RELAYRELAYEVAPORATOR MOTORFAN CAPACITOREQUPIMENT GROUNDHIGH PRESSURE SWITCHHIGH VOLTAGE DEFROST RELAYLOW PRESSURE SWITCHLOW VOLTAGE DEFROST RELAYLOW VOLTAGE JUNCTION BOXPOWER DISTRIBUTION BLOCKFEMALE PLUG / CONNECTORREVERSING VAVLE COILTERMINAL BLOCK (24V SIGNAL)TRANSFORMER
LVDR
W2 DFT
R
DFT2
C
BC
CCCMCMCCOMPDCDFTECONEBTDEMRREMFCGNDHPSHVDRLPSLVDRLVJBPBPLFRVCTB1TR
6
COMPONENT LEGEND
R
R
C
208-240/460/575/3/60 0140L02578-A
PLF1
G
NOTES:
1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY.2. USE COPPER CONDUCTORS ONLY ++ USE N.E.C. CLASS 2 WIRE3. ECONOMIZER PLUG LOCATED IN THE RETURN AIR COMPARTMENT. REMOVE MALE PLUG AND ATTACH FEMALE PLUG TO THE ECONOMIZER ACCESSORY.4. FOR TWO STAGE OPERATION REMOVE W1 TO W2 JUMPER WIRE.
EBTDR
CC1
DC
HPS1
LPS1
LOW VOLTAGE
LINE VOLTAGE
FIELD WIRING
LOW VOLTAGE OPTIONAL
HIGH VOLTAGE
FACTORY WIRING
HIGH VOLTAGE
CC2
++
GR GREEN
WIRE CODE
BL BLUE
PU PURPLEPK PINK
WH WHITE
BK BLACK
RD RED
BR BROWN
OR ORANGE
YL YELLOWYL/PK YELLOW WITH PINK STRIPBL/PK BLUE WITH PINK STRIP
CMC
CMC
FC2
CM2
T2
CC2
T3
T1COMP2
CC2T1
CC2T2
CMC
CC1
L2
T3
COMP1
F
SUPPLY VOLTAGE
CM1
L1
CC1T1
C
CC1
L3208-240/440/575/3/60
T2
TR24V
8
7
9
ORO O
BL
Y1
GR
PK
TB1
W1
RG
C
R
2 STAGE COOLING
Y2
YL
G
C
WH
Y2
Y1
STAT
W1
RD
THERMOSTATFIELD WIRING
W2 BR W2
SSHRNONC
9
7
8 56
4
32
1
SEE NOTE 3
O
SSHR SECOND STAGE HEATER RELAY
T2
BC2
EM
CB2BC2
HIGH SPEED
LOW SPEEDCB2
BC1CB1
BC1
BC1
BR1
BR1
BR2BR3
BR2
BR3
CCR1
CCR2
CCR1
CCR2
LPS2HPS2
CB1
EBTDR
BLOWER RELAYCIRCUIT BREAKERCOMPRESSOR CONTACTOR RELAY
BRCBCCR
FC
BC2CB2
BC1CB1
4
5
2
4
5
24
5
2
DFT1R
DR NODRNC
TR24V
C
TR24V
RVC1
FC1
5. MOVE WIRE(S) TO APPROPRIATE INPUTVOLTAGE TERMINAL ON TRANSFORMER.
CSEE NOTE 5
SEE NOTE 5
NOTE 4TB1
TO THERMOSTAT
RO G CY1W1W2S2S1 RO G CY1W1W2 Y2S2S1
Wiring Diagram – DCH 10 – 12½ (230V/ 460V/ 575V, 2-Speed, 3-Phase Belt Drive)
38 www.daikinac.com SS-DCH7 SS-DCH7 www.daikinac.com 39
WIRING DIAGRAMS FOR MODELS WITH DDC CONTROLSFor complete information and installation instructions for models
with DDC controls, see manual DK-DDC-TGD-XXX
40 www.daikinac.com SS-DCH7 SS-DCH7 www.daikinac.com 41
Wiri
ng is
subj
ect t
o ch
ange
. Alw
ays
refe
r to
the
wiri
ng d
iagr
am o
n th
e un
it fo
r the
mos
t up-
to-d
ate
wiri
ng.
⚠
War
ning
High
Vol
tage
: Di
scon
nect
all
pow
er b
efor
e se
rvic
ing
or in
stal
ling
this
unit.
Mul
tiple
pow
er
sour
ces m
ay b
e pr
esen
t. Fa
ilure
to d
o so
may
caus
e pr
oper
ty d
amag
e, p
erso
nal i
njur
y, or
dea
th.⚡
Wiring Diagram with DDC – DCH090*/ DCH102* 208 - 230, 460, 575 / 3 / 60 2SP
RLY
2R
LY1
56
BM
T3L3
T1T2
L1L2C
OM
P1
CF1
L 2B
R BK
BK
BC
1
CFC
CC
1
RD
YL BK
T 2 T1L 1
BL
014
0L05
760-
A
BR
T3L3
T1T2
L1L2
CF2
BR
PU
PU
FC2
BR
T3L3
T1T2
L1L2
CC
2
YL RD BK
RD
CO
MP2
BL
BL
RD R
D RD
RD
BK
T1
T2T3T3
T2
T1
BL
BK
BK
PU
PU
RD
FC1
RD
OR
RD
RD
BK
BL
BL
BLBL
RD
OR
BL
RD
BL
BL
PU
BLB
L BK
RD
BL
BK
BK
EC
ON
XS(C
LAS
S2)
RD
DA
OA
T
ES
PS
C STB
1T 1
24V
AC
CFS
RS
S
LDS
CO
2
T 2T 3
T 4T 5
SM
K/E
MG
2
BK
PKP
K
PK
GY
BL/
PK
BL/
PK
GY
LPS1
HP
S2
YL
HP
S1
LPS
2
PU
BL/
PK
BL/P
KYL
/PK
YL/P
K
YL/P
K
YL/P
K
PK
BK
YL
PU
YL
DFT
DFT
RD
RD
RD
GN
D24
VA
COA
HVO
UT
(DC
)
GN
D24
VA
C (C
OM
)24
VA
C
VOU
T (D
C)
VO
UT
(DC
)
24 V
ACIAH G
ND
BI8
BI5
121110
1
CO
M3-
8
BI1
BI2
BI3
BI4
BI7 GN
D
24V
AC
BR
RD
OR
CO
M3-
8
CO
M1
BL
PU
PU
(OAT
)
(DFT
)(C
FS)
(EM
ER
)(F
AN
PR
OV
)
(RE
V V
LV)
(CF)
(HE
AT 2
)(H
EAT
1)
YL
BI6
(SH
ED
)
CO
M2
(24V
IN)
(EC
ON
PW
R)
(EXF
)(A
LRM
)
(EC
ON
DM
PR
)
(OA
H)
(ISO
L G
ND
)
(SP
C T
MP
)(C
O2)
2345678 12
1 2 3 4 5 6 7 8 9
DD
C (
CLA
SS
2)
(EC
ON
FB
)
RV
2
C
GR
(CLA
SS2)
TB2
DA
T
(CO
MP2
OU
T)(C
OM
P1 O
UT)
(CO
MP1
IN)
(CO
MP2
IN)
YL YL
RV
1
BKB
K
123
123
4 2 16 5 39 8 7
HTR
PLF
1H
TRP
LM1
HTR
PLF
2
WH
BR
654321 A
O1
AO
2 A
O3
AO
4G
ND
GN
D
RD
RD
RD
OR
OR
AG
SPC
TEM
P TEM
P
GN
DS
TPT
OFF
SE
T
GR
BR
BR
BK
BK
PU
PU
GR
GR
BR
BR
BR
GR
BR
BR
GR
RD
RD
RD
RD
BL
BL
BL
BL
BL
BR
BR
PU
PKPK
PU
YL
BK RD
BK
RD
RD
BL/
PK
BL/
PK
PU
PU YL
PU
PU
RD
YL
PU
BR
YL
BK
BL
BL
BK
WH
PK
3 124
WH
WH
BK
PKWH
BR
ALR
M-
+
EXF
-+
GRG
R
RD
BR B
LWH
8 7 6 5 4 3 2 19 A
I3
AI8
AI7
AI6
AI5
AI4
AI1
AI2
AG
ND
AG
ND
10
GR
WH
WH
PU
BK
PU
PK
PLF
WH
WH
BL
BL
BLB
L
BL
BL
BL
BL
BL
24V
208
C3
224
01
TR2
5
24V
208
C3
224
01
TR1
RD
RD
RD
OR
RD
OR
RD
RD
RD
OR
RD
RD
PO
WE
RS
UPP
LY
PB
L3
GND
BKR
D
OR
OR
BL
BL
PU
BL
BL
BL
BL
BL
BL
OR
BL
4
6
OR
L1
BK
L2 BK
RDO
RL1
L2L3
LIN
E V
OLT
AG
E
YLYL
YL
RD
GR
GR
EE
N
WIR
E C
ODE
BL
B
LUE
PU
PU
RPL
EP
K
PIN
K
WH
W
HIT
E
BK
BLA
CK
RD
RE
D
BR
BR
OW
N
OR
OR
AN
GE
YL
Y
ELL
OW
GY
G
RA
Y
-t°
3
BA
C N
ET
3T-
21(B
AC
NE
T)R
+S
H
BLO
WE
R C
ON
TAC
TOR
BC
CO
MP
RE
SSO
R C
ON
TAC
TOR
CO
MP
RE
SSO
R
EC
ON
OM
IZE
R
HIG
H P
RE
SS
UR
E S
WIT
CH
PO
WE
R D
ISTR
IBU
TIO
N B
LOC
KFE
MA
LE P
LUG
/CO
NN
EC
TOR
TER
MIN
AL
BLO
CK
(24V
SIG
NA
L)
CC
CO
MP
EC
ON
HP
S
PB PLF
TB
CO
MPO
NEN
T LE
GEN
D
CIR
CU
IT B
RE
AKE
RC
B TRGN
D
BC
SB
LOW
ER
CU
RR
EN
T S
WIT
CH
BM
BLO
WE
R M
OTO
R
CFC
CO
ND
EN
SE
R F
AN
CO
NTA
CTO
RC
FSC
LOG
GE
D F
ILTE
R S
WIT
CH
CF
CO
ND
EN
SE
R F
AN
DAT
DIS
CH
AR
GE
AIR
TE
MP
ER
ATU
RE
SE
NS
OR
DD
CD
IRE
CT
DIG
ITA
L C
ON
TRO
LD
FTD
EFR
OST
TH
ER
MO
STA
T S
WIT
CH
CO
2C
AR
BO
N D
IOXI
DE
SE
NS
OR
FCFA
N C
AP
AC
ITO
RE
QU
IPM
EN
T G
RO
UN
D
EXF
EXH
AU
ST
FAN
IAH
IND
OO
R A
IR H
UM
IDIT
Y S
EN
SO
R
LOW
PR
ES
SU
RE
SW
ITC
HLP
S
RV
RE
VE
RS
ING
VA
LVE
RS
SR
EM
OTE
STA
RT/
STO
P
OA
TO
UTD
OO
R A
IR T
EM
PE
RA
TUR
E S
EN
SO
RO
AH
OU
TDO
OR
AIR
HU
MID
ITY
SE
NSO
R
LDS
LOA
D S
HE
DD
ING
SP
CTE
MP
SP
AC
E T
EM
PE
RA
TUR
E S
EN
SOR
TRA
NS
FOR
ME
R
YL/P
K
YELL
OW
WIT
H
P
INK
STR
IPE
BL/
PK
BL
UE
WIT
H
P
INK
STR
IPE
+-
HG
RH
BL
BL
BL
OR
BL
RD
RD
BK
ALR
MA
LAR
M
HG
RH
HO
T G
AS
RE
HE
AT
SM
KS
MO
KE
DE
TEC
TOR
BL
BR
BL
PU
PU
RD
RD
GR
GR
RD
OR
T3L3
T1T2
L1L2
BC
2
BR
BK
BK
BK
BK
BLBL
RD
BKBKBK
OR
OR
RD
RD
BK
BK
BK
NO
TES:
1. R
EPLA
CEM
EN
T W
IRE
MU
ST
BE S
AM
E S
IZE
AN
D T
YPE
OF
INS
ULA
TIO
N A
S O
RIG
INA
L (A
T LE
AST
105°
C).
US
E C
OPP
ER
CO
ND
UC
TOR
S O
NLY
.
USE
N.E
.C. C
LAS
S 2
WIR
E F
OR
ALL
LO
W V
OLT
AG
E F
IELD
CO
NN
EC
TIO
NS
.
I
F O
PTIO
NA
L S
MO
KE D
ETE
CTO
R IS
INS
TALL
ED
, REM
OV
E R
ED
JU
MP
ER
WIR
E C
ON
NE
CTI
ON
S T
B1-
XS T
O T
B1-
ES.
D
ISC
HA
RG
E A
IR T
EM
PER
ATU
RE
SEN
SOR
SH
IPP
ED
WIT
H U
NIT
IN C
ON
TRO
L B
OX.
INST
ALL
AN
D C
ON
NE
CT
PE
R T
HE
ATT
AC
HE
D IN
STR
UC
TIO
NS
/WIR
ING
DIA
GR
AM.
I
F O
PTIO
NA
L E
CO
NO
MIZ
ER
IS IN
STA
LLE
D, C
ON
NE
CT
EC
ON
PLF
TO
EC
ON
OM
IZE
R. E
CO
NO
MIZ
ER
PLU
G L
OC
ATE
D IN
TH
E R
ETU
RN
AIR
CO
MPA
RTM
EN
T.
(
208/
230)
V U
NIT
S: IF
UN
IT U
TILI
ZES
208
V S
UPP
LY P
OW
ER
, MO
VE
TR1/
2 H
IGH
VO
LTA
GE
RED
WIR
E F
RO
M T
HE
240
V T
ER
MIN
AL T
O T
HE
208
V T
ER
MIN
AL
46
0V, 5
75V
UN
ITS:
RE
D W
IRE
CO
NN
EC
TED
TO
AP
PR
OP
RIA
TE H
IGH
VO
LTA
GE
INP
UT
TER
MIN
AL
ON
TR
1/2
I
F O
PTIO
NA
L E
LEC
TRIC
HEA
T IS
INST
ALL
ED
, CO
NN
EC
T H
TR P
LF2
TO A
CC
ESSO
RY
HEA
T P
LUG
IN H
EA
T C
OM
PAR
TME
NT.
2 3 4 5 6
BC
S
BKBK
BK
BK
RDBL
RLY
8R
LY7
RLY
6R
LY5
RLY
4R
LY3
L
OW
VO
LTA
GE
H
IGH
VO
LTA
GE
FIEL
D W
IRIN
G
L
OW
VO
LTA
GE
FAC
TORY
WIR
ING
H
IGH
VO
LTA
GE
OP
TIO
NAL
LO
W V
OLT
AG
E
OPT
IONA
L AC
CESS
OR
IES
OR
FIE
LD S
UPP
LIED
BLB
LBL
BR
RD
OR
BR
BR
BL
RD
RD
BKBR
OR
BK
ORR
DBK
BK
GY
YLBL
BL
WH
OR
PO
WER
& C
ON
TRO
L W
IRIN
G D
IAG
RA
MD
CH
(090
-102
)***
*VD
DC
BK
RD
BK
RD
OR
OR
OR
5
BK
OR
BK
(SU
PPLY
AIR
TM
P)
(RM
T S
TRT/
STP
)
(MO
D H
GR
H)
(SP
C H
UM
)
(CO
MP
PR
ESS
1)
(BLO
WE
R S
TAG
E 1
)
(CO
MP
PR
ESS
2)
(BLO
WE
R S
TAG
E 2
)
(SP
C S
LID
E A
DJ)
RD
BL
RD
OR
BL
OR
BL
BL
BL
BL BLB
L
OR
BL
GR
RD
RD
BL
BL
BL
BR
PU
BLBL
BLP
U
GR
GR
RD
WH
BLB
L
BL
BL
GY
PLM
MA
LE P
LUG
/CO
NN
EC
TOR
-t°
40 www.daikinac.com SS-DCH7 SS-DCH7 www.daikinac.com 41
Wiri
ng is
subj
ect t
o ch
ange
. Alw
ays
refe
r to
the
wiri
ng d
iagr
am o
n th
e un
it fo
r the
mos
t up-
to-d
ate
wiri
ng.
⚠
War
ning
High
Vol
tage
: Di
scon
nect
all
pow
er b
efor
e se
rvic
ing
or in
stal
ling
this
unit.
Mul
tiple
pow
er
sour
ces m
ay b
e pr
esen
t. Fa
ilure
to d
o so
may
caus
e pr
oper
ty d
amag
e, p
erso
nal i
njur
y, or
dea
th.⚡
Wiring Diagram with DDC – DCH120*/ DCH150* 208 - 230, 460, 575 / 3 / 60 2SP
RLY
2R
LY1
56
BM
T3L3
T1T2
L1L2C
OM
P1
CF1
L 2B
R BK
BK
BC
1
CFC
CC
1
OR BK
RDYL BK
T 2 T1L 1
BL
014
0L05
746-
A
BR
T3L3
T1T2
L1L2
CF2
BR
PU
PU
FC2
BR
T3L3
T1T2
L1L2
CC
2
YL RD
BK
RD
CO
MP2
BL
BL
RD R
D RD
RD
BK
T1
T2T3T3
T2
T1
BL
BK
BK
PU
PU
RD
FC1
RD
OR RD
RD
BK
BL
BL
BLBL
RD
OR
BL
RD
BL
BL
PU
PU
BL
BL
BK
RD
BL
BK
BK
EC
ON
XS(C
LAS
S2)
RD
DA
OA
T
ES
PS
C STB
1T 1
24V
AC
CFS
RS
S
LDS
CO
2
T 2T 3
T 4T 5
SM
K/E
MG
2
BK
PK
PK
PK
GY
BL/P
K
BL/
PK
GY
LPS
1
HP
S2
YL
HP
S1
LPS
2
PU
BL/
PK
BL/
PK
YL/P
K
YL/P
K
YL/P
K
YL/P
K
PK
BK
YL
PU
YL
DFT
DFT
RD
RD
RD
GN
D24
VACO
AH
VO
UT
(DC
)
GN
D24
VA
C (C
OM
)24
VACVO
UT
(DC
)
VO
UT
(DC
)
24 V
ACIAH G
ND
BI8
BI5
121110
1
CO
M3-
8
BI1
BI2
BI3
BI4
BI7 GN
D
24V
AC
BR
RD
OR
CO
M3-
8
CO
M1
BL
PU
PU
(OA
T)
(DFT
)(C
FS)
(EM
ER
)(F
AN
PR
OV
)
(REV
VLV
)(C
F)(H
EAT
2)(H
EAT
1)
YL
BI6
(SH
ED
)
CO
M2
(24V
IN)
(EC
ON
PW
R)
(EXF
)(A
LRM
)
(EC
ON
DM
PR
)
(OA
H)
(ISO
L G
ND
)
(SP
C T
MP
)(C
O2)
2345678 12
1 2 3 4 5 6 7 8 9
DD
C (
CLA
SS2
)
(EC
ON
FB
)
RV2
C
GR
(CLA
SS
2)TB
2
DAT
(CO
MP
2 O
UT)
(CO
MP
1 O
UT)
(CO
MP
1 IN
)
(CO
MP
2 IN
)
YL YL
RV1
BK
BK
123
123
4 2 16 5 39 8 7
HTR
PLF
1H
TRPL
M1
HTR
PLF
2
WH
BR
654321 A
O1
AO
2 A
O3
AO
4G
ND
GN
D
RD
RD
RD
OR
OR
AG
SPC
TEM
P TEM
P
GN
DS
TPT
OFF
SE
T
GR
BR
BR
BKB
K
PU
PU
GR
GR
BR
BR
BR
GR
BR
BR
GR
RD
RD
RD
RD
BL
BL
BL
BL
BL
BR
BR
PU
PKPK
PU
YL
BK
RD
BK
RD
RD
BL/
PK
BL/
PK
PU
PU
YL
PU
PU
RD
YL
PU
BR
YL
BK
BL
BL
BK
WH
PK
3 124
WH
WH
BK
PK
WH
BR
ALR
M-
+
EXF
-+
GRG
R
RD
BR B
LWH
8 7 6 5 4 3 2 19 A
I3
AI8
AI7
AI6
AI5
AI4
AI1
AI2
AG
ND
AG
ND
10
GR
WH
WH
PU
BK
PU
PK
PLF
WH
WH
BL
BL
BLB
L
BL
BL
BL
BL
BL
24V
208
C3
224
01
TR2
5
24V
208
C3
224
01
TR1
RD
RD
RD
OR
RD
OR
RD
RD
RD
OR
RD
RD
PO
WE
RS
UP
PLY
PB
L3
GND
BKR
D
OR
OR
BL
BL
PU
BL
BL
BL
BL
BL
BL
OR
BL
4
6
OR
L1
BK
L2 BK
RDO
RL1
L2L3
LIN
E V
OLT
AG
E
YL
YLYL
RD
GR
GR
EE
N
WIR
E C
ODE
BL
BLU
E
PU
PU
RP
LEP
K
P
INK
WH
W
HIT
E
BK
BLA
CK
RD
RE
D
BR
BR
OW
N
OR
OR
AN
GE
YL
Y
ELL
OW
GY
G
RA
Y
-t°
3
BA
C N
ET3
T-21
(BA
CN
ET)
R+
SH
BLO
WE
R C
ON
TAC
TOR
BC
CO
MPR
ESS
OR
CO
NTA
CTO
R
CO
MPR
ESS
OR
ECO
NO
MIZ
ER
HIG
H P
RES
SUR
E S
WIT
CH
PO
WE
R D
ISTR
IBU
TIO
N B
LOC
KFE
MA
LE P
LUG
/CO
NN
EC
TOR
TER
MIN
AL
BLO
CK
(24V
SIG
NA
L)
CC
CO
MP
ECO
N
HP
S
PB PLF TBC
OM
PON
ENT
LEG
END
CIR
CU
IT B
RE
AKER
CB TRGN
D
BCS
BLO
WE
R C
UR
RE
NT
SW
ITC
HB
MB
LOW
ER
MO
TOR
CFC
CO
ND
EN
SER
FAN
CO
NTA
CTO
RC
FSC
LOG
GED
FIL
TER
SW
ITC
H
CF
CO
ND
EN
SER
FAN
DA
TD
ISC
HA
RG
E A
IR T
EM
PER
ATU
RE
SE
NS
OR
DD
CD
IREC
T D
IGIT
AL
CO
NTR
OL
DFT
DE
FRO
ST
THE
RM
OS
TAT
SW
ITC
H
CO
2C
ARB
ON
DIO
XID
E S
EN
SO
R
FCFA
N C
APA
CIT
OR
EQ
UIP
ME
NT
GR
OU
ND
EXF
EXH
AUS
T FA
N
IAH
IND
OO
R A
IR H
UM
IDIT
Y S
ENS
OR
LOW
PR
ESSU
RE
SW
ITC
HLP
S
RV
REV
ERS
ING
VA
LVE
RSS
RE
MO
TE S
TAR
T/S
TOP
OA
TO
UTD
OO
R A
IR T
EM
PER
ATU
RE
SEN
SO
RO
AHO
UTD
OO
R A
IR H
UM
IDIT
Y S
ENS
OR
LDS
LOAD
SH
EDD
ING
SPC
TEM
PS
PAC
E T
EM
PER
ATU
RE
SE
NS
OR
TRAN
SFO
RM
ER
YL/P
K
YELL
OW
WIT
H
P
INK
STR
IPE
BL/
PK
B
LUE
WIT
H
P
INK
STR
IPE
+-
HG
RH
BL
BL
BL
OR
BL
RD
RD
BK
ALR
MA
LAR
M
HG
RH
HO
T G
AS
REH
EAT
SM
KS
MO
KE D
ETE
CTO
R
BL
BR
BL
PU
PU
RD
RD
GR
GR
RD
OR
T3L3
T1T2
L1L2
BC
2
BR
BK
BK
BK
BK
BK
GY BL YL
BLBL
T1L1
CB1
(HI S
PD
)
RD
YLYL
YLO
R RD
BK
OR
OR
RD
RD
BK
BK
BK
NO
TES
:
1. R
EP
LAC
EM
EN
T W
IRE
MU
ST
BE
SA
ME
SIZ
E A
ND
TYP
E O
F IN
SU
LATI
ON
AS
OR
IGIN
AL
(AT
LEA
ST
105°
C).
US
E C
OP
PE
R C
ON
DU
CTO
RS
ON
LY.
U
SE
N.E
.C. C
LAS
S 2
WIR
E F
OR
ALL
LO
W V
OLT
AG
E F
IELD
CO
NN
EC
TIO
NS
.
I
F O
PTI
ON
AL
SM
OK
E D
ETE
CTO
R IS
INS
TALL
ED
, RE
MO
VE
RE
D J
UM
PE
R W
IRE
CO
NN
EC
TIO
NS
TB1-
XS T
O T
B1-
ES
.
D
ISC
HA
RG
E A
IR T
EM
PE
RAT
UR
E S
EN
SO
R S
HIP
PE
D W
ITH
UN
IT IN
CO
NTR
OL
BO
X.IN
STA
LL A
ND
CO
NN
EC
T P
ER
TH
E A
TTA
CH
ED
INS
TRU
CTI
ON
S/W
IRIN
G D
IAG
RA
M.
I
F O
PTI
ON
AL
EC
ON
OM
IZE
R IS
INS
TALL
ED
, CO
NN
EC
T E
CO
N P
LF T
O E
CO
NO
MIZ
ER
. EC
ON
OM
IZE
R P
LUG
LO
CA
TED
IN T
HE
RE
TUR
N A
IR C
OM
PA
RTM
EN
T.
(
208/
230)
V U
NIT
S: IF
UN
IT U
TILI
ZES
208
V S
UPP
LY P
OW
ER
, MO
VE T
R1/
2 H
IGH
VO
LTAG
E R
ED
WIR
E F
RO
M T
HE
240V
TE
RM
INA
L TO
TH
E 2
08V
TE
RM
INAL
460V
, 575
V U
NIT
S: R
ED
WIR
E C
ON
NE
CTE
D T
O A
PP
RO
PR
IATE
HIG
H V
OLT
AG
E IN
PU
T TE
RM
INA
L O
N T
R1/
2
I
F O
PTI
ON
AL
ELE
CTR
IC H
EA
T IS
INST
ALL
ED
, CO
NN
EC
T H
TR P
LF2
TO A
CC
ES
SO
RY
HE
AT
PLU
G IN
HE
AT C
OM
PA
RTM
EN
T.
2 3 4 5 6
BC
S
BKB
K BK
BK
RDB
L
RLY
8R
LY7
RLY
6R
LY5
RLY
4R
LY3
L
OW
VO
LTA
GE
H
IGH
VO
LTA
GE
FIEL
D W
IRIN
G
L
OW
VO
LTA
GE
FACT
OR
Y W
IRIN
G
H
IGH
VO
LTAG
E
OP
TIO
NA
L L
OW
VO
LTA
GE
OPT
IONA
L AC
CESS
OR
IES
OR
FIE
LD S
UPPL
IED
BL
BL
BL
BR
RD
OR
BR
BR
BL
RD
RD
BR
BK
BR
OR
BK
OR
BK
T2L2
T3L3
T1L1
CB
2(L
O S
PD
) T2L2
T3L3
GY YLBL
BK
BK
PO
WE
R &
CO
NTR
OL
WIR
ING
DIA
GR
AM
DC
H(1
20-1
50)*
***V
DD
C
BK
RD
BK
RD
OR
OR
5
BK
BK
(SU
PPL
Y A
IR T
MP
)
(RM
T ST
RT/
STP
)
(MO
D H
GR
H)
(SP
C H
UM
)
(CO
MP
PR
ESS
1)
(BLO
WE
R S
TAG
E 1
)
(CO
MP
PR
ES
S 2
)
(BLO
WE
R S
TAG
E 2
)
(SP
C S
LID
E A
DJ)
RD
RD
OR
BL
BL
BL
BLBL
BL
BL
OR
WH
RD
GR
PU
YL
BLBL
BLB
RR
D
RD
OR
BK
BK
BL
BL
BL
PU
RD
GR
GR
GR
BL
BL
BL
BR
GY
PLM
MA
LE P
LUG
/CO
NN
ECTO
R
-t°
42 www.daikinac.com SS-DCH7 SS-DCH7 www.daikinac.com 43
Accessories
Daikin MasterItem # Description Fits Model Sizes Field-
InstalledFactory-Installed
Operating Weight (lbs)
Curb14CURB90150 14” Roof Curb 7½-12½ tons √ 143
18CURB90150 18” Roof Curb 7½-12½ tons √ 165
24CURB90150 24” Roof Curb 7½-12½ tons √ 197
GHRC-90150 Hurricane Restraint Clips 7½-12½ tons √ 2
Ultra Low-Leak Economizer & Power Exhaust11036610B Ultra Low-Leak Downflow Economizer w/ Enthalpy 7½-12½ tons √ √ 137
1039610B Ultra Low-Leak Horizontal Economizer w/ Enthalpy 7½-12½ tons √ 137
104651021 Prop Power Exhaust 230v 7½-12½ tons √ 55
104651031 Prop Power Exhaust 460v 7½-12½ tons √ 55
104651041 Prop Power Exhaust 575v 7½-12½ tons √ 55
Low-Leak Economizer & Power Exhaust2DDNECNJ90150B Low-Leak Downflow Economizer 7½-12½ tons √ √ 130
DPE901502 Downflow Power Exhaust (208/230v) 7½-12½ tons √ 65
DPE901504 Downflow Power Exhaust (460v) 7½-12½ tons √ 65
DPE901507 Downflow Power Exhaust (575v) 7½-12½ tons √ 65
DINHZ90150B Horizontal Economizer, Internally Mounted 7½-12½ tons √ 110
DHZECNJ90150 Horizontal Economizer 7½-12½ tons √ 90
DHPE901502 Horizontal Power Exhaust (208/230v) 7½-12½ tons √ 65
DHPE901504 Horizontal Power Exhaust (460v) 7½-12½ tons √ 65
DHPE901507 Horizontal Power Exhaust (575v) 7½-12½ tons √ 65
Downflow AccessoriesD25FD90150 25% Manual Fresh Air Damper 7½-12½ tons √ 15
D25MFD90150 25% Motorized Fresh Air Damper 7½-12½ tons √ 21
DDNBBS90150 Burglar Bar Sleeves: includes Supply & Return 7½-12½ tons √ 45
DDNECNJ90150NR Low-Leak Downflow Economizer w/o Barometric Relief
7½-12½ tons √ 130
DDNSQRD9020 Downflow Square-to-Round Adapter 20” Round
7½ tons √ 55
Horizontal AccessoriesDBRD3672 Horizontal Barometric Relief Damper
(2 required)7½-12½ tons √ 30
ConcentricsCDK90102 Concentric Duct Kit 7½-8½ tons √ 42
CDK120 Concentric Duct Kit 10 tons √ 104
CDK150 Concentric Duct Kit 12½ tons √ 151
3 phase 208-230V Electric Heat KitsEHK3-16 16kw 208-230v 3ph Electric Heat Kit 7½-12½ tons √ √ 21
EHK3-30 30kw 208-230v 3ph Electric Heat Kit 7½-12½ tons √ √ 21
EHK3-45 45kw 208-230v 3ph Electric Heat Kit 7½-12½ tons √ √ 21
42 www.daikinac.com SS-DCH7 SS-DCH7 www.daikinac.com 43
Accessories
Daikin MasterItem # Description Fits Model Sizes Field-
InstalledFactory-Installed
Operating Weight (lbs)
3 phase 460V Electric Heat KitsEHK4-16 16kw 460v 3ph Electric Heat Kit 7½-12½ tons √ √ 21
EHK4-30 30kw 460v 3ph Electric Heat Kit 7½-12½ tons √ √ 21
EHK4-45 45kw 460v 3ph Electric Heat Kit 7½-12½ tons √ √ 21
3 phase 575V Electric Heat KitsEHK7-16 16kw 575v 3ph Electric Heat Kit 7½-12½ tons √ √ 21
EHK7-30 30kw 575v 3ph Electric Heat Kit 7½-12½ tons √ √ 21
EHK7-45 45kw 575v 3ph Electric Heat Kit 7½-12½ tons √ √ 21
DDC Accessories3
DDC communicating controller (built-in BACnet® MS/TP) includes Standard Room Sensor to be installed in field
7½-12½ tons √ 2
10366D10B DDC Ultra Low-Leak Downflow Economizer 7½-12½ tons √ √ 71
10396D10 DDC Ultra Low-Leak Horizontal Economizer 7½-12½ tons √ 71
10465DDC Power Exhaust kit used with DDC Ultra Low-Leak Economizer
7½-12½ tons √ 1
DLAKT03 Low-Ambient 7½-12½ tons √ √ 2
LONKT01 LonWorks® card 7½-12½ tons √ 1
3PMK01 Phase Monitor (3-Phase Only) 7½-12½ tons √ √ 2
DFSKT01 Dirty Filter Switch 7½-12½ tons √ 1
High-Static KitsHSKTW090FI High Static, Factory Installed (230/460/575v) 7½ tons √ 10
HSKTW102FI High Static, Factory Installed (230/460/575v) 8½ tons √ 10
HSKTW120-3FIHP High Static, Factory Installed (208/230v) 10 tons HP √ 60
HSKTW120-4FIHP High Static, Factory Installed (460v) 10 tons HP √ 60
HSKTW120-7FIHP High Static, Factory Installed (575v) 10 tons HP √ 60
HSKTW150-3FI High Static, Factory Installed (230v) 12½ tons √ 40
HSKTW150-4FI High Static, Factory Installed (460v) 12½ tons √ 40
HSKTW150AC-7FI High Static, Factory Installed (575v) 12½ tons AC/HP √ 35
Crankcase Heater Kits0130L00017S 70W 230V 7½-12½ tons √ 1
0130L00018S 70W 460V 7½-12½ tons √ 1
0130L00019S 70W 575V 7½-12½ tons √ 1
High Efficiency Filters0160L00205 High Efficiency MERV 13 Air Filter Nom.
Size: 16x20x2; (Order Qty 4)7.5 tons √ 4
0160L00206 High Efficiency MERV 13 Air Filter Nom. Size: 16x24x2; (Order Qty 4)
8.5 & 10 tons √ 4
0160L00202 High Efficiency MERV 13 Air Filter Nom. Size: 20x25x2; (Order Qty 4)
12.5 tons √ 6
44 www.daikinac.com SS-DCH7 SS-DCH7 www.daikinac.com PB
Our continuing commitment to quality products may mean a change in specifications without notice. © 2018 • Houston, Texas • Printed in the USA.
Accessories
Daikin MasterItem # Description Fits Model Sizes Field-
InstalledFactory-Installed
Operating Weight (lbs)
Misc AccessoriesHailGD02D Condenser Coil Hail Guard 7½-10 tons √ 34
HailGD05D Condenser Coil Hail Guard 12½ tons √ 37
Convenience Outlet: Powered 7½-12½ tons √ 42
Convenience Outlet: Non Powered 7½-12½ tons √ 2
Disconnect Switch (non-fused) 7½-12½ tons √ 5
LAKT17 Low-Ambient Kit, 208-230V - non-DDC 7½-8½ tons √ √ 23
LAKT18 Low-Ambient Kit, 460V - non-DDC 7½-8½ tons √ √ 23
LAKT19 Low-Ambient Kit, 575V - non-DDC 7½-8½ tons √ √ 23
LAKT20 Low-Ambient Kit, 208-230V - non-DDC 10-12½ tons √ √ 23
LAKT21 Low-Ambient Kit, 460V - non-DDC 10-12½ tons √ √ 23
LAKT22 Low-Ambient Kit, 575V - non-DDC 10-12½ tons √ √ 23
3PMNDK01 Phase Monitor - Non DDC 7½-12½ tons √ √ 2
Smoke Detector (supply and/or return air) 7½-12½ tons √ 11
Hinged Panels 7½-12½ tons √ 341 Use Economizer & Power Exhaust listed within Ultra Low-Leak section 2 Use Economizer & Power Exhaust listed within Low-Leak section 3 For a full list of DDC accessories, please refer to DDC Controller Technical Guide manual (DK-DDC-TGD-01B)Note: Where multiple variations are available, the heaviest combination is listed.