Declaration of ConformityIn Accordance with ANSI/ISEA 125-2014
Alexander Andrew, Inc. 1306 S. Alameda St Compton, CA 90221
Declaration # S1017023 Declaration Date 10.18.17
Tested Item # 6050428WR 5pc Confined Space Davit System with Winch and SRL-R
Additional Items Conforming Under this Declaration:
Alexander Andrew, Inc. declares that the product(s) listed above is in conformity with the requirements of the following performance standard(s):
5pc Davit System- OSHA 1926.502 and 1910.66 120' Personnel Winch- ANSI Z359.4-2013 60' SRL-R- ANSI Z359.14-2014
Conformity Assessment Method in accordance with ANSI/ISEA 125-2014
Level 1 Level 2 Level 3
Level 1: FallTech LabOutside the Scope of
ISO/IEC Standard 17025:2005
Level 2: FallTech Lab Within the Scope of
ISO/IEC Standard 17025:2005
Level 3: Independent 3rd Party Lab accredited to
ISO/IEC Standard 17025:2005
Supporting Documentation PC-0898 PC-0865 PC-1264 PC-0865DPT-000046
Authorized Signature
Martin Barila VP of Operations 10.26.17
FallTech Testing Laboratory 1306 S. Alameda Street,
Compton, CA 90221-4803Tel: (323) 752-0060
www.falltech.com
Certificate# TL-594 Testing
FLT-08 Rev. H Page 1 of 2
PC-0898 Rpt. Date 8/3/2017 Rpt. Rev Rev Date
Mark Sasaki
Date
Date
Date
Sample ID Description6500128 11"-28" Offset Davit Arm
Zack Winters, Tyler WilsonDate Complete 3/31/2017PC-0898
Test Operator(s)
See attached PC-0898 Protocol
See attached PC-0898 ProtocolSee attached PC-0898
ResultsSee attached PC-0898
Results
Material/Sample Identification
Test Specification Test Criteria Test Result Pass/Fail
Witnessed by
FallTech P/N 6500128 11"-28" Offset Arm and the 6500657 57" Lower Mast/Extension meet the requirements of OSHA 1926, OSHA 1910, and FallTech's General Manufacturing Requirements.
Lab Quality Manager
Test Summary
Test Report No.
Test Request No.
Initiated By Part No.
FallTech Test Report
Test Specification(s)
Part Description
OSHA 1926 & 1910, No Applicable ANSI StandardFallTech
11"-28" Offset Davit Arm and 57" Lower Mast ExtensionPart No. Revision A6500128 & 6500657
Report Prepared For
Conclusion
Report Signatories and Approval
Director of Engineering 10/9/2017
6500657 57" Lower Mast/Extension
10/9/2017
Not Required N/A
FallTech Testing Laboratory 1306 S. Alameda Street,
Compton, CA 90221-4803Tel: (323) 752-0060
www.falltech.com
Certificate# TL-594 Testing
FLT-08 Rev. H Page 2 of 2
PC-0898 Rpt. Date 8/3/2017 Rpt. Rev Rev Date
Mark Sasaki
Date Complete 3/31/2017PC-0898
Test Report No.
Test Request No.
Initiated By Part No.
FallTech Test Report
Test Specification(s)
Part Description
OSHA 1926 & 1910, No Applicable ANSI StandardFallTech
11"-28" Offset Davit Arm and 57" Lower Mast ExtensionPart No. Revision A6500128 & 6500657
Report Prepared For
Characteristic
See attached PC-0898 Protocol
Ambient Conditions, Indoors
Description of Test 11"-28" Offset Davit Arm with 57" Lower Mast/Extension Static Pull Test
Acceptance Criteria See attached PC-0898 Protocol
Test By Test DateZack Winters, Tyler Wilson 3/31/2017
Time Removed from Conditioning
Test Method See attached PC-0898 Protocol
Test Procedure See attached PC-0898 ProtocolConditioning Requirements
10,000 Lbf Load Cell (+/- 0.5%) 342183 4/25/2018
N/A Time Tested N/A
N/A Actual Conditions Ambient
Test Information
Test Environment
Test Results
End of Report
See attached PC-0898 Protocol
See attached PC-0898 Protocol
See attached PC-0898 Test Results
See attached PC-0898 Test Results
Sample ID Criteria Test Data Pass/Fail
Size/TypeEquipment Used
Equipment Used Control Number Calibration Date10k Load Cell
FallTech Testing Laboratory 1306 S. Alameda Street,
Compton, CA 90221-4803Tel: (323) 752-0060
www.falltech.com
Certificate# TL-594 Testing
FLT-08 Rev. H Page 1 of 2
DTP-000046 Rpt. Date 9/26/2017 Rpt. Rev Rev Date
Mark Sasaki
Date
Date
Date
10/9/2017
Not Required N/A
Report Signatories and Approval
N/A Time Tested N/A
N/A Actual Conditions Ambient
Test Information
Test Environment
Director of Engineering 10/9/2017
Witnessed by
Acceptance Criteria
FallTech P/N 6500728 meets the requirements of OSHA 1926.502, OSHA 1910, and FallTech's General Manufacturing Requirements.
Lab Quality Manager
Test Summary
Time Removed from Conditioning
Test Report No.
Test Request No.
Initiated By Part No.
FallTech Test Report
Test Specification(s)
Part Description
OSHA 1926 & 1910, No Applicable ANSI StandardFallTech
Confined Space Davit 3-PC Portable BasePart No. Revision A6500728
Report Prepared For
Conclusion
Test Method See attached DTP-000046 Protocol
Test Procedure See attached DTP-000046 ProtocolConditioning Requirements
See attached DTP-000046 Protocol
Test By Test DateZack Winters, Tyler Wilson 4/11/2017Ambient Conditions, Indoors
Description of Test 3-PC Portable Base Static Pull test
See attached DTP-000046 Protocol
See attached DTP-000046 ProtocolSee attached DTP-
000046 ResultsSee attached DTP-000046
Results
Material/Sample IdentificationSample ID Description
6500728 Confined Space Davit 3-PC Portable Base
Zack Winters, Tyler WilsonDate Complete 4/11/2017DTP-000046
Test Operator(s)
Test Specification Test Criteria Test Result Pass/Fail
FallTech Testing Laboratory 1306 S. Alameda Street,
Compton, CA 90221-4803Tel: (323) 752-0060
www.falltech.com
Certificate# TL-594 Testing
FLT-08 Rev. H Page 2 of 2
DTP-000046 Rpt. Date 9/26/2017 Rpt. Rev Rev Date
Mark Sasaki
Date Complete 4/11/2017DTP-000046
Test Report No.
Test Request No.
Initiated By Part No.
FallTech Test Report
Test Specification(s)
Part Description
OSHA 1926 & 1910, No Applicable ANSI StandardFallTech
Confined Space Davit 3-PC Portable BasePart No. Revision A6500728
Report Prepared For
Characteristic
See attached DTP-000046 Protocol
4/25/2018
Test Results
End of Report
See attached DTP-000046 Protocol
See attached DTP-000046 Protocol
See attached DTP-00004 Test Results
See attached DTP-00046 Test Results
Sample ID Criteria Test Data Pass/Fail
Size/TypeEquipment Used
Equipment Used Control Number Calibration Date10k Load Cell 10,000 Lbf Load Cell (+/-0.5%) 342183
Page 1 of 2
This attestation is issued in accordance with our terms and conditions, a copy of which is available on request. Exova OCM 3883 East Eagle Drive Anaheim, CA 92807 USA
371456-8 FallTech, PC-1264, 7298 ANSI Z359.4 Witness test
October 26, 2017
FallTech Testing Laboratory 1306 S. Alameda Street Compton, CA 90221 Attention: Jay Sponholz Quality Manager Subject: Attestation of Witnessing Testing
Exova OCM Job # 371456-8 FallTech P.O.: OPEN Report No.: PC-1264 Base Part No. 7298 Description: Personnel Winch
Dear Mr. Sponholz: The purpose of this attestation is to attest to the fact that a representative of Exova OCM was on site at FallTech’s facilities to confirm suitability of the equipment used, calibration status of the equipment and to witness testing performed by FallTech employees. Details of this visit are included below:
• Date of Testing: − October 5, 2017
• Exova OCM Test Witness: − 10/5/17 - Nolan Schatzle
• FallTech Test Operators: − Yesbet Sierra/Jay Sponholz
• Specification: ANSI Z359.4-2013 Sections: 3.3, 4.3.6, 4.3.2.1, 4.3.2.2, 4.3.2.3
• Equipment Calibration Interval − 1 year, except weights which are 5 years
FallTech Testing Laboratory 1306 S. Alameda Street,
Compton, CA 90221-4803
Tel: (323) 752-0060
www.falltech.com
PC-1264 Rpt. Date 10/18/2017 Rpt. Rev Rev Date
Dan Redden
4028969h Personnel Winch
4028966c Personnel Winch
4028968w Personnel Winch
4028975 Personnel Winch
4028974 Personnel Winch
Personnel Winch4028967
Material/Sample Identification
Sample ID Description
Personnel Winch
4028975 Personnel Winch
4028974 Personnel Winch
4028967 Personnel Winch
Yesbet Sierra / Jay Sponholz
Date Complete 10/12/2017PC-1264
Test Operator(s)
Test Report No.
Test Request No.
Initiated By
Part No.
Personnel Winch
4028973w
FallTech Test Report
Test Specification(s)
Part Description
ANSI Z359.4-2013: 3.3, 4.3.6,
4.3.2.1, 4.3.2.2, 4.3.2.3
FallTech
Personnel Winch
Part No. Revision A7298
Report Prepared For
4028962 Personnel Winch
4028964 Personnel Winch
4028961 Personnel Winch
4028975 Personnel Winch
4028974 Personnel Winch
4028967 Personnel Winch
4028975 Personnel Winch
4028974 Personnel Winch
4028967 Personnel Winch
4028978h Personnel Winch
4028970c
Certificate# TL-594 Testing
FLT-08 Rev. H
Page 1 of 25
FallTech Testing Laboratory 1306 S. Alameda Street,
Compton, CA 90221-4803
Tel: (323) 752-0060
www.falltech.com
PC-1264 Rpt. Date 10/18/2017 Rpt. Rev Rev Date
Dan Redden
Date Complete 10/12/2017PC-1264
Test Report No.
Test Request No.
Initiated By
Part No.
FallTech Test Report
Test Specification(s)
Part Description
ANSI Z359.4-2013: 3.3, 4.3.6,
4.3.2.1, 4.3.2.2, 4.3.2.3
FallTech
Personnel Winch
Part No. Revision A7298
Report Prepared For
Static Strength
Maintain load
Static Strength
Maintain load
Static Strength
Maintain load
4028959h Personnel Winch
4028975c Personnel Winch
4028960w Personnel Winch
4028965 Personnel Winch
4028977 Personnel Winch
4028963
Pass
> 1 Minute 1 Minute Pass
ANSI Z359.4-2013
4.3.6.1
> 3100 Lbf 3278.9 lbF Pass
> 1 Minute 1 Minute Pass
ANSI Z359.4-2013
4.3.6.1
> 3100 Lbf 3164.8 lbF
ANSI Z359.4-2013
4.3.6.1
> 3100 Lbf 3165.3 lbF Pass
> 1 Minute 1 Minute Pass
Test Summary
Test Specification Test Criteria Test Result Pass/Fail
Personnel Winch
4028978h Personnel Winch
4028970c Personnel Winch
4028973w Personnel Winch
Material/Sample Identification (Continued)
Sample ID Description
Certificate# TL-594 Testing
FLT-08 Rev. H
Page 2 of 25
FallTech Testing Laboratory 1306 S. Alameda Street,
Compton, CA 90221-4803
Tel: (323) 752-0060
www.falltech.com
PC-1264 Rpt. Date 10/18/2017 Rpt. Rev Rev Date
Dan Redden
Date Complete 10/12/2017PC-1264
Test Report No.
Test Request No.
Initiated By
Part No.
FallTech Test Report
Test Specification(s)
Part Description
ANSI Z359.4-2013: 3.3, 4.3.6,
4.3.2.1, 4.3.2.2, 4.3.2.3
FallTech
Personnel Winch
Part No. Revision A7298
Report Prepared For
Static Strength
Maintain load
Static Strength
Maintain load
Slippage
(Post Static)
Primary Brake
(Post Static)
Static Strength
Maintain load
Static Strength
Maintain load
Slippage
(Post Static)
Primary Brake
(Post Static)
Static Strength
Maintain load
Static Strength
Maintain load
Slippage
(Post Static)
Primary Brake
(Post Static)
ANSI Z359.4-2013
4.3.6.2
> 1240 Lbf 1324.0 lbF Pass
> 1 Minute 1 Minute Pass
> 1240 Lbf 1296.5 lbF Pass
> 1 Minute 1 Minute Pass
Raise / Lower without
slippageNo Slippage Pass
< 4" travel when control
released
Average of 3 readings
> 1240 Lbf 1289.9 lbF Pass
0.0" Pass
> 1 Minute 1 Minute Pass
ANSI Z359.4-2013
4.3.6.2
> 1240 Lbf 1293.6 lbF Pass
> 1 Minute 1 Minute Pass
> 1240 Lbf 1297.0 lbF Pass
> 1 Minute 1 Minute Pass
Raise / Lower without
slippageNo Slippage Pass
< 4" travel when control
released
Average of 3 readings
0.0" Pass
Test Summary (Continued)
Test Specification Test Criteria Test Result Pass/Fail
ANSI Z359.4-2013
4.3.6.2
> 1240 Lbf 1272.7 lbF Pass
> 1 Minute 1 Minute Pass
Raise / Lower without
slippageNo Slippage Pass
< 4" travel when control
released
Average of 3 readings
0.0" Pass
Certificate# TL-594 Testing
FLT-08 Rev. H
Page 3 of 25
FallTech Testing Laboratory 1306 S. Alameda Street,
Compton, CA 90221-4803
Tel: (323) 752-0060
www.falltech.com
PC-1264 Rpt. Date 10/18/2017 Rpt. Rev Rev Date
Dan Redden
Date Complete 10/12/2017PC-1264
Test Report No.
Test Request No.
Initiated By
Part No.
FallTech Test Report
Test Specification(s)
Part Description
ANSI Z359.4-2013: 3.3, 4.3.6,
4.3.2.1, 4.3.2.2, 4.3.2.3
FallTech
Personnel Winch
Part No. Revision A7298
Report Prepared For
Force to Raise
Force to Lower
Force to Raise
Force to Lower
Force to Raise
Force to Lower
Force to Raise
Force to Lower
Force to Raise
Force to Lower
Force to Raise
Force to Lower Pass
< 30.0 Lbf
Average of 3 readings27.4 lbF
16.7 lbF
ANSI Z359.4-2013
4.3.6.3
Pass
< 30.0 Lbf
Average of 3 readings21.7 lbF Pass
Test Summary (Continued)
Test Specification Test Criteria Test Result Pass/Fail
ANSI Z359.4-2013
4.3.6.3
< 30.0 Lbf
Average of 3 readings25.0 lbF Pass
< 30.0 Lbf
Average of 3 readingsPass
ANSI Z359.4-2013
4.3.6.3 / 4.3.2.1
< 30.0 Lbf
Average of 3 readings25.4 lbF Pass
< 30.0 Lbf
Average of 3 readings10.9 lbF Pass
ANSI Z359.4-2013
4.3.6.3
< 30.0 Lbf
Average of 3 readings25.0 lbF Pass
< 30.0 Lbf
Average of 3 readings13.4 lbF Pass
ANSI Z359.4-2013
4.3.6.3 / 4.3.2.2
< 30.0 Lbf
Average of 3 readings26.0 lbF Pass
< 30.0 Lbf
Average of 3 readings5.8 lbF Pass
ANSI Z359.4-2013
4.3.6.3 / 4.3.2.3
< 30.0 Lbf
Average of 3 readings25.2 lbF Pass
< 30.0 Lbf
Average of 3 readings6.2 lbF
Certificate# TL-594 Testing
FLT-08 Rev. H
Page 4 of 25
FallTech Testing Laboratory 1306 S. Alameda Street,
Compton, CA 90221-4803
Tel: (323) 752-0060
www.falltech.com
PC-1264 Rpt. Date 10/18/2017 Rpt. Rev Rev Date
Dan Redden
Date Complete 10/12/2017PC-1264
Test Report No.
Test Request No.
Initiated By
Part No.
FallTech Test Report
Test Specification(s)
Part Description
ANSI Z359.4-2013: 3.3, 4.3.6,
4.3.2.1, 4.3.2.2, 4.3.2.3
FallTech
Personnel Winch
Part No. Revision A7298
Report Prepared For
Slippage
Slippage
Slippage
Slippage
Slippage
Slippage
Primary Brake
Primary Brake
Primary Brake
Primary Brake
Primary Brake
Primary Brake
ANSI Z359.4-2013
4.3.6.5 / 4.3.2.2
< 4" travel when control
released
Average of 3 readings
0.0" Pass
ANSI Z359.4-2013
4.3.6.5 / 4.3.2.3
< 4" travel when control
released
Average of 3 readings
0.0" Pass
ANSI Z359.4-2013
4.3.6.5
< 4" travel when control
released
Average of 3 readings
0.0" Pass
ANSI Z359.4-2013
4.3.6.5
< 4" travel when control
released
Average of 3 readings
0.0" Pass
0.0" Pass
ANSI Z359.4-2013
4.3.6.4 / 4.3.2.2
Raise / Lower without
slippageNo Slippage Pass
ANSI Z359.4-2013
4.3.6.4 / 4.3.2.3
Raise / Lower without
slippageNo Slippage Pass
ANSI Z359.4-2013
4.3.6.4 / 4.3.2.1
ANSI Z359.4-2013
4.3.6.5 / 4.3.2.1
< 4" travel when control
released
Average of 3 readings
Raise / Lower without
slippageNo Slippage Pass
ANSI Z359.4-2013
4.3.6.4
Raise / Lower without
slippageNo Slippage Pass
ANSI Z359.4-2013
4.3.6.4
ANSI Z359.4-2013
4.3.6.4
Raise / Lower without
slippageNo Slippage Pass
Raise / Lower without
slippageNo Slippage Pass
ANSI Z359.4-2013
4.3.6.5
< 4" travel when control
released
Average of 3 readings
0.0" Pass
Test Summary (Continued)
Test CriteriaTest Specification Test Result Pass/Fail
Certificate# TL-594 Testing
FLT-08 Rev. H
Page 5 of 25
August 15, 2016
FallTech Testing Laboratory 1306 S. Alameda Street Compton, CA 90221 Attention: Jay Sponholz Quality Manager Subject: Attestation of Witnessing Testing
Exova OCM Job # 361179-2 FallTech P.O.: OPEN Report No.: PC-0865 Base Part No. 7281 Description: 60' Cable 3-Way Self-Retracting Device
Dear Mr. Sponholz: The purpose of this attestation is to attest to the fact that a representative of Exova OCM was on site at FallTech’s facilities to confirm suitability of the equipment used, calibration status of the equipment and to witness testing performed by FallTech employees. Details of this visit are included below:
• Date of Testing: − June 9, 33, 2016
• Exova OCM Test Witness: − Robert Fortner
• FallTech Test Operators: − Yesbet Sierra and Jay Sponholz
• Specification: − ANSI Z359.14-2014 Sections 4.2.1, 4.2.3, 4.2.5, 4.2.6, 4.2.8.1, 4.2.8.2, 4.2.8.3
• Equipment Calibration Interval − 1 year, except weights which are 5 years
Page 1 of 2
This attestation is issued in accordance with our terms and conditions, a copy of which is available on request. Exova OCM 3883 East Eagle Drive Anaheim, CA 92807 USA
361179-2 FallTech (PC-0865, 7281) ANSI Z359.14 Witness test.docx
Exova OCM
Attached to this attestation is the test report generated by FallTech Testing Laboratory. Exova OCM test witness certifies the report accurately presents the testing performed on the samples identified.
Test Report # Date
PC-0865 7/8/2016
Test Witness Signature:
Robert Fortner Technician Mechanical Laboratory
Approval Signature:
Mark E. Kokosinski General Manager
Base Part# Description Sample ID's Results FT15026 FT16272 FT15042 FT16260 FT16259 FT15078 FT15026 FT16272 FT15042 FT16287 FT17267
60' Cable 3-Way Self-Retracting FT17299 7281
Device FT16279 Pass
FT15071 FT16299 FT15028 FT15080 FT16258 FT16272 FT15026 FT15048 FT15075 FT16294 FT15059
(Signed for and on behalf of Exova-OCM)
R.r.
(Signed for a'J! o'J'eha/f ~f ~ova-OCM)
~.£~'
This attestation shall not be reproduced except in full, without the written approval of Exova-OCM. The laboratory has witnessed the testing the material I items supplied by the client as sampled by the client. The testing is not within Exova OCM's L.A.B scope of testing and was not performed at Exova OCM.
FallTech Testing Laboratory Attestation Number: 36179-2
Revision Letter: Original Page 2 of 2
Exova OCM 3883 East Eagle Drive Anaheim , CA 92807 USA
FallTech Testing Laboratory 1306 S. Alameda Street,
Compton, CA 90221-4803
Tel: (323) 752-0060
www.falltech.com
PC-0865 Date 7/8/2016 Rev Rev Date
Report Prepared For
Dan Redden
7281
N/A BOM No
PC-0865 6/7/2016 6/29/2016
Yesbet Sierra
FT15075 60' Cable 3-Way Self Retracting Device
FT16294 60' Cable 3-Way Self Retracting Device
FT15059 60' Cable 3-Way Self Retracting Device
FT17299
FT16272 60' Cable 3-Way Self Retracting Device
FT15026 60' Cable 3-Way Self Retracting Device
FT15048 60' Cable 3-Way Self Retracting Device
60' Cable 3-Way Self Retracting Device
60' Cable 3-Way Self Retracting Device
60' Cable 3-Way Self Retracting Device
FT15026
60' Cable 3-Way Self Retracting Device
60' Cable 3-Way Self Retracting Device
60' Cable 3-Way Self Retracting Device
FT15078
60' Cable 3-Way Self Retracting Device
FT16260
FT16259
60' Cable 3-Way Self Retracting Device
60' Cable 3-Way Self Retracting Device
60' Cable 3-Way Self Retracting Device
60' Cable 3-Way Self Retracting Device
60' Cable 3-Way Self Retracting Device
FT16272
FT15042
FT16287
FT17267
60' Cable 3-Way Self Retracting Device
Test Report Number
Test Request #
Initiated By
Base Part #
FallTech Test Report
Test Specification
Date Received Date Complete
Description
ANSI Z359.14-2014 4.3.1, 4.3.3, 4.2.1,
4.3.4, 4.2.8.1, 4.2.8.2, 4.2.8.3, 4.2.5, 4.2.6,
60' Cable 3-Way Self Retracting Device
ProductionProposed Part #
FallTech
Built By Whom
FT15026 60' Cable 3-Way Self Retracting Device
Test Operator Test Operator Jay Sponholz
Material/Sample Identification
Sample ID Description
FT15042
60' Cable 3-Way Self Retracting Device
60' Cable 3-Way Self Retracting Device
60' Cable 3-Way Self Retracting Device
FT16272 60' Cable 3-Way Self Retracting Device
FT16279
FT15071
FT16299
FT15028
FT15080
FT16258
Certificate# TL-594 Testing
FLT-08 Rev. G
Page 1 of 26
FallTech Testing Laboratory 1306 S. Alameda Street,
Compton, CA 90221-4803
Tel: (323) 752-0060
www.falltech.com
PC-0865 Date 7/8/2016 Rev Rev Date
Report Prepared For
Dan Redden
7281
N/A BOM No
PC-0865 6/7/2016 6/29/2016
Test Report Number
Test Request #
Initiated By
Base Part #
FallTech Test Report
Test Specification
Date Received Date Complete
Description
ANSI Z359.14-2014 4.3.1, 4.3.3, 4.2.1,
4.3.4, 4.2.8.1, 4.2.8.2, 4.2.8.3, 4.2.5, 4.2.6,
60' Cable 3-Way Self Retracting Device
ProductionProposed Part #
FallTech
Built By Whom
Functional 36" Travel
125 % Maximum Capacity
Hold
Functional 36" Travel
75 % Minimum Capacity
Hold
Functional 36" Travel
125 % Maximum Capacity
Hold
Functional 36" Travel
75 % Minimum Capacity
Hold
Functional 36" Travel
125 % Maximum Capacity
Hold
Functional 36" Travel
75 % Minimum Capacity
Hold
Static Strength
Rescue Mode
Static Strength
Rescue Mode
Static Strength
Rescue Mode
Test Specification Test Criteria Test Result Pass/Fail
Test Summary
ANSI Z359.14-2014
4.3.1
< 4" Vertical
Displacement0.0" Pass
1 Minute 1 Minute Pass
< 4" Vertical
Displacement0.0" Pass
1 Minute 1 Minute Pass
ANSI Z359.14-2014
4.3.1
< 4" Vertical
Displacement0.0" Pass
1 Minute 1 Minute Pass
< 4" Vertical
Displacement 0.0" Pass
1 Minute 1 Minute Pass
ANSI Z359.14-2014
4.3.1
< 4" Vertical
Displacement0.0" Pass
1 Minute 1 Minute Pass
< 4" Vertical
Displacement0.0" Pass
1 Minute 1 Minute Pass
ANSI Z359.14-2014
4.3.3
> 3,000 Lbf
for > 60 Seconds3106.2 lbF Pass
ANSI Z359.14-2014
4.3.3
> 3,000 Lbf
for > 60 Seconds3054.0 lbF Pass
ANSI Z359.14-2014
4.3.3
> 3,000 Lbf
for > 60 Seconds3053.5 lbF Pass
Certificate# TL-594 Testing
FLT-08 Rev. G
Page 2 of 26
FallTech Testing Laboratory 1306 S. Alameda Street,
Compton, CA 90221-4803
Tel: (323) 752-0060
www.falltech.com
PC-0865 Date 7/8/2016 Rev Rev Date
Report Prepared For
Dan Redden
7281
N/A BOM No
PC-0865 6/7/2016 6/29/2016
Test Report Number
Test Request #
Initiated By
Base Part #
FallTech Test Report
Test Specification
Date Received Date Complete
Description
ANSI Z359.14-2014 4.3.1, 4.3.3, 4.2.1,
4.3.4, 4.2.8.1, 4.2.8.2, 4.2.8.3, 4.2.5, 4.2.6,
60' Cable 3-Way Self Retracting Device
ProductionProposed Part #
FallTech
Built By Whom
Arrest Distance
Max Arrest Force
Avg Arrest Force
Post Fall Rescue Mode
Functional Travel
Visual Impact Indicator
Retraction Tension
0% Extracted
Retraction Tension
20% Extracted
Retraction Tension
40% Extracted
Retraction Tension
60% Extracted
Retraction Tension
80% Extracted
Retraction Tension
100% Extracted
Arrest Distance
Max Arrest Force
Avg Arrest Force
Post Fall Rescue Mode
Functional Travel
Visual Impact Indicator
Retraction Tension
0% Extracted
Retraction Tension
20% Extracted
Retraction Tension
40% Extracted
Retraction Tension
60% Extracted
Retraction Tension
80% Extracted
Retraction Tension
100% Extracted
Pass
Class A < 24"
Class B < 54"Pass
1592.1 lbF< 1800 Lbf
1.25 Lbf - 25 Lbf
< 24" Extended5.4 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended7.8 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended7.4 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended
1.25 Lbf - 25 Lbf
< 24" Extended7.2 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended7.0 lbF Pass
Visual Deployment Visually Deployed Pass
50% Arrest Distance
< 4" Vertical Displacement
11.4" Travel
0.0" DisplacementPass
1.25 Lbf - 25 Lbf
< 24" Extended4.4 lbF Pass
ANSI Z359.14-2014
4.2.1, 4.2.6, 4.3.4
Class A < 1350 Lbf
Class B < 900 Lbf
50% Arrest Distance
< 4" Vertical Displacement
1060.1 lbF Pass
11.1" Travel
0.0" DisplacementPass
22.2"
Pass7.6 lbF
Visual Deployment Visually Deployed Pass
ANSI Z359.14-2014
4.2.1, 4.2.6, 4.3.4
Class A < 24"
Class B < 54"22.8" Pass
< 1800 Lbf 1855.1 lbF Pass
Class A < 1350 Lbf
Class B < 900 Lbf1227.6 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended4.4 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended5.4 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended6.2 lbF
Pass
1.25 Lbf - 25 Lbf
< 24" Extended8.4 lbF Pass
Pass
1.25 Lbf - 25 Lbf
< 24" Extended6.8 lbF
Certificate# TL-594 Testing
FLT-08 Rev. G
Page 3 of 26
FallTech Testing Laboratory 1306 S. Alameda Street,
Compton, CA 90221-4803
Tel: (323) 752-0060
www.falltech.com
PC-0865 Date 7/8/2016 Rev Rev Date
Report Prepared For
Dan Redden
7281
N/A BOM No
PC-0865 6/7/2016 6/29/2016
Test Report Number
Test Request #
Initiated By
Base Part #
FallTech Test Report
Test Specification
Date Received Date Complete
Description
ANSI Z359.14-2014 4.3.1, 4.3.3, 4.2.1,
4.3.4, 4.2.8.1, 4.2.8.2, 4.2.8.3, 4.2.5, 4.2.6,
60' Cable 3-Way Self Retracting Device
ProductionProposed Part #
FallTech
Built By Whom
Arrest Distance
Max Arrest Force
Avg Arrest Force
Post Fall Rescue Mode
Functional Travel
Visual Impact Indicator
Retraction Tension
0% Extracted
Retraction Tension
20% Extracted
Retraction Tension
40% Extracted
Retraction Tension
60% Extracted
Retraction Tension
80% Extracted
Retraction Tension
100% Extracted
Arrest Distance
Max Arrest Force
Avg Arrest Force
Post Fall Rescue Mode
Functional Travel
Visual Impact Indicator
Retraction Tension
0% Extracted
Retraction Tension
20% Extracted
Retraction Tension
40% Extracted
Retraction Tension
60% Extracted
Retraction Tension
80% Extracted
Retraction Tension
100% Extracted
Class A < 24"
Class B < 54"
< 1800 Lbf
Class A < 1575 Lbf
Class B < 1125 Lbf
23.0"
1681.6 lbF
1024.2 lbF
Pass
Pass
8.0 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended
Visual Deployment Visually Deployed Pass
50% Arrest Distance
< 4" Vertical Displacement
11.5" Travel
0.0" DisplacementPass
ANSI Z359.14-2014
4.2.8.1, 4.3.4
1.25 Lbf - 25 Lbf
< 24" Extended4.4 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended5.2 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended5.8 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended6.6 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended8.2 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended7.4 lbF Pass
Pass
ANSI Z359.14-2014
4.2.1, 4.2.6, 4.3.4
Class A < 24"
Class B < 54"22.8" Pass
< 1800 Lbf 1756.2 lbF Pass
Class A < 1350 Lbf
Class B < 900 Lbf1178.2 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended5.8 lbF Pass
Visual Deployment Visually Deployed Pass
50% Arrest Distance
< 4" Vertical Displacement
11.4" Travel
0.0" DisplacementPass
1.25 Lbf - 25 Lbf
< 24" Extended7.0 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended
7.6 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended4.2 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended5.4 lbF Pass
Certificate# TL-594 Testing
FLT-08 Rev. G
Page 4 of 26
FallTech Testing Laboratory 1306 S. Alameda Street,
Compton, CA 90221-4803
Tel: (323) 752-0060
www.falltech.com
PC-0865 Date 7/8/2016 Rev Rev Date
Report Prepared For
Dan Redden
7281
N/A BOM No
PC-0865 6/7/2016 6/29/2016
Test Report Number
Test Request #
Initiated By
Base Part #
FallTech Test Report
Test Specification
Date Received Date Complete
Description
ANSI Z359.14-2014 4.3.1, 4.3.3, 4.2.1,
4.3.4, 4.2.8.1, 4.2.8.2, 4.2.8.3, 4.2.5, 4.2.6,
60' Cable 3-Way Self Retracting Device
ProductionProposed Part #
FallTech
Built By Whom
Arrest Distance
Max Arrest Force
Avg Arrest Force
Post Fall Rescue Mode
Functional Travel
Visual Impact Indicator
Retraction Tension
0% Extracted
Retraction Tension
20% Extracted
Retraction Tension
40% Extracted
Retraction Tension
60% Extracted
Retraction Tension
80% Extracted
Retraction Tension
100% Extracted
Arrest Distance
Max Arrest Force
Avg Arrest Force
Post Fall Rescue Mode
Functional Travel
Visual Impact Indicator
Retraction Tension
0% Extracted
Retraction Tension
20% Extracted
Retraction Tension
40% Extracted
Retraction Tension
60% Extracted
Retraction Tension
80% Extracted
Retraction Tension
100% Extracted
Pass
Class A < 1575 Lbf
Class B < 1125 Lbf951.3 lbF Pass
< 1800 Lbf 1365.5 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended6.4 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended9.4 lbF Pass
Class A < 24"
Class B < 54"
50% Arrest Distance
< 4" Vertical Displacement
9.6" Travel
0.0" DisplacementPass
Class A < 24"
Class B < 54"
1426.2 lbF Pass
Class A < 1575 Lbf
Class B < 1125 Lbf995.2 lbF Pass
50% Arrest Distance
< 4" Vertical Displacement
11.0" Travel
0.0" DisplacementPass
Visual Deployment Visually Deployed Pass
1.25 Lbf - 25 Lbf
< 24" Extended4.0 lbF Pass
22.0"
1.25 Lbf - 25 Lbf
< 24" Extended5.4 lbF Pass
ANSI Z359.14-2014
4.2.8.1, 4.3.4
1.25 Lbf - 25 Lbf
< 24" Extended6.8 lbF Pass
ANSI Z359.14-2014
4.2.8.1, 4.3.4
Visual Deployment Visually Deployed Pass
1.25 Lbf - 25 Lbf
< 24" Extended4.4 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended5.4 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended6.4 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended7.2 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended8.8 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended7.2 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended7.2 lbF Pass
Pass
< 1800 Lbf
19.2"
Certificate# TL-594 Testing
FLT-08 Rev. G
Page 5 of 26
FallTech Testing Laboratory 1306 S. Alameda Street,
Compton, CA 90221-4803
Tel: (323) 752-0060
www.falltech.com
PC-0865 Date 7/8/2016 Rev Rev Date
Report Prepared For
Dan Redden
7281
N/A BOM No
PC-0865 6/7/2016 6/29/2016
Test Report Number
Test Request #
Initiated By
Base Part #
FallTech Test Report
Test Specification
Date Received Date Complete
Description
ANSI Z359.14-2014 4.3.1, 4.3.3, 4.2.1,
4.3.4, 4.2.8.1, 4.2.8.2, 4.2.8.3, 4.2.5, 4.2.6,
60' Cable 3-Way Self Retracting Device
ProductionProposed Part #
FallTech
Built By Whom
Arrest Distance
Max Arrest Force
Avg Arrest Force
Post Fall Rescue Mode
Functional Travel
Visual Impact Indicator
Retraction Tension
0% Extracted
Retraction Tension
20% Extracted
Retraction Tension
40% Extracted
Retraction Tension
60% Extracted
Retraction Tension
80% Extracted
Retraction Tension
100% Extracted
Arrest Distance
Max Arrest Force
Avg Arrest Force
Post Fall Rescue Mode
Functional Travel
Visual Impact Indicator
Retraction Tension
0% Extracted
Retraction Tension
20% Extracted
Retraction Tension
40% Extracted
Retraction Tension
60% Extracted
Retraction Tension
80% Extracted
Retraction Tension
100% Extracted
ANSI Z359.14-2014
4.2.8.2, 4.3.4
ANSI Z359.14-2014
4.2.8.2, 4.3.4
< 1800 Lbf 1757.2 lbF Pass
Class A < 1575 Lbf
Class B < 1125 Lbf1191.9 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended4.0 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended
Class A < 24"
Class B < 54"22.8 Pass
< 1800 Lbf 1739.2 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended7.0 lbF
24.6" Pass
7.6 lbF Pass
Pass
1.25 Lbf - 25 Lbf
< 24" Extended7.2 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended7.4 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended
Class A < 1575 Lbf
Class B < 1125 Lbf1145.1 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended4.4 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended5.0 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended6.4 lbF Pass
50% Arrest Distance
< 4" Vertical Displacement
11.4" Travel
0.0" DisplacementPass
Visual Deployment Visually Deployed Pass
Pass
1.25 Lbf - 25 Lbf
< 24" Extended7.0 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended7.0 lbF Pass
Class A < 24"
Class B < 54"
5.6 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended7.0 lbF
50% Arrest Distance
< 4" Vertical Displacement
12.3" Travel
0.0" DisplacementPass
Visual Deployment Visually Deployed Pass
Certificate# TL-594 Testing
FLT-08 Rev. G
Page 6 of 26
FallTech Testing Laboratory 1306 S. Alameda Street,
Compton, CA 90221-4803
Tel: (323) 752-0060
www.falltech.com
PC-0865 Date 7/8/2016 Rev Rev Date
Report Prepared For
Dan Redden
7281
N/A BOM No
PC-0865 6/7/2016 6/29/2016
Test Report Number
Test Request #
Initiated By
Base Part #
FallTech Test Report
Test Specification
Date Received Date Complete
Description
ANSI Z359.14-2014 4.3.1, 4.3.3, 4.2.1,
4.3.4, 4.2.8.1, 4.2.8.2, 4.2.8.3, 4.2.5, 4.2.6,
60' Cable 3-Way Self Retracting Device
ProductionProposed Part #
FallTech
Built By Whom
Arrest Distance
Max Arrest Force
Avg Arrest Force
Post Fall Rescue Mode
Functional Travel
Visual Impact Indicator
Retraction Tension
0% Extracted
Retraction Tension
20% Extracted
Retraction Tension
40% Extracted
Retraction Tension
60% Extracted
Retraction Tension
80% Extracted
Retraction Tension
100% Extracted
Arrest Distance
Max Arrest Force
Avg Arrest Force
Post Fall Rescue Mode
Functional Travel
Visual Impact Indicator
Retraction Tension
0% Extracted
Retraction Tension
20% Extracted
Retraction Tension
40% Extracted
Retraction Tension
60% Extracted
Retraction Tension
80% Extracted
Retraction Tension
100% Extracted
Pass
< 1800 Lbf 1841.1 lbF
ANSI Z359.14-2014
4.2.8.2, 4.3.4
Class A < 24"
Class B < 54"23.4"
Pass
1.25 Lbf - 25 Lbf
< 24" Extended
Pass
Class A < 1575 Lbf
Class B < 1125 Lbf985.5 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended4.0 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended5.2 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended6.6 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended6.6 lbF
8.0 lbF Pass
50% Arrest Distance
< 4" Vertical Displacement
11.7" Travel
0.0" DisplacementPass
Visual Deployment Visually Deployed Pass
1.25 Lbf - 25 Lbf
< 24" Extended7.4 lbF Pass
ANSI Z359.14-2014
4.2.8.3, 4.3.4
Class A < 24"
Class B < 54"28.0" Pass
< 1800 Lbf 1618.9 lbF Pass
Class A < 1575 Lbf
Class B < 1125 Lbf999.0 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended4.8 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended6.0 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended7.2 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended7.4 lbF
14.0" Travel
0.0" DisplacementPass
Visual Deployment Visually Deployed Pass
Pass
1.25 Lbf - 25 Lbf
< 24" Extended7.2 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended7.2 lbF Pass
50% Arrest Distance
< 4" Vertical Displacement
Certificate# TL-594 Testing
FLT-08 Rev. G
Page 7 of 26
FallTech Testing Laboratory 1306 S. Alameda Street,
Compton, CA 90221-4803
Tel: (323) 752-0060
www.falltech.com
PC-0865 Date 7/8/2016 Rev Rev Date
Report Prepared For
Dan Redden
7281
N/A BOM No
PC-0865 6/7/2016 6/29/2016
Test Report Number
Test Request #
Initiated By
Base Part #
FallTech Test Report
Test Specification
Date Received Date Complete
Description
ANSI Z359.14-2014 4.3.1, 4.3.3, 4.2.1,
4.3.4, 4.2.8.1, 4.2.8.2, 4.2.8.3, 4.2.5, 4.2.6,
60' Cable 3-Way Self Retracting Device
ProductionProposed Part #
FallTech
Built By Whom
Arrest Distance
Max Arrest Force
Avg Arrest Force
Post Fall Rescue Mode
Functional Travel
Visual Impact Indicator
Retraction Tension
0% Extracted
Retraction Tension
20% Extracted
Retraction Tension
40% Extracted
Retraction Tension
60% Extracted
Retraction Tension
80% Extracted
Retraction Tension
100% Extracted
Arrest Distance
Max Arrest Force
Avg Arrest Force
Post Fall Rescue Mode
Functional Travel
Visual Impact Indicator
Retraction Tension
0% Extracted
Retraction Tension
20% Extracted
Retraction Tension
40% Extracted
Retraction Tension
60% Extracted
Retraction Tension
80% Extracted
Retraction Tension
100% Extracted
ANSI Z359.14-2014
4.2.8.3, 4.3.4
1.25 Lbf - 25 Lbf
< 24" Extended7.8 lbF
Class A < 24"
Class B < 54"25.4"
1.25 Lbf - 25 Lbf
< 24" Extended3.8 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended6.0 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended6.2 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended9.0 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended7.4 lbF Pass
Pass
Pass
< 1800 Lbf 1438.4 lbF
ANSI Z359.14-2014
4.2.8.3, 4.3.4
Class A < 24"
Class B < 54"25.4" Pass
< 1800 Lbf 1204.5 lbF Pass
Class A < 1575 Lbf
Class B < 1125 Lbf838.3 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended4.6 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended5.8 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended6.6 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended7.0 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended8.2 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended8.4 lbF Pass
50% Arrest Distance < 4"
Vertical Displacement
12.7" Travel
0.0" DisplacementPass
Visual Deployment Visually Deployed Pass
50% Arrest Distance
< 4" Vertical Displacement
12.7" Travel
0.0" DisplacementPass
Visual Deployment Visually Deployed Pass
Pass
Class A < 1575 Lbf
Class B < 1125 Lbf920.7 lbF Pass
Certificate# TL-594 Testing
FLT-08 Rev. G
Page 8 of 26
FallTech Testing Laboratory 1306 S. Alameda Street,
Compton, CA 90221-4803
Tel: (323) 752-0060
www.falltech.com
PC-0865 Date 7/8/2016 Rev Rev Date
Report Prepared For
Dan Redden
7281
N/A BOM No
PC-0865 6/7/2016 6/29/2016
Test Report Number
Test Request #
Initiated By
Base Part #
FallTech Test Report
Test Specification
Date Received Date Complete
Description
ANSI Z359.14-2014 4.3.1, 4.3.3, 4.2.1,
4.3.4, 4.2.8.1, 4.2.8.2, 4.2.8.3, 4.2.5, 4.2.6,
60' Cable 3-Way Self Retracting Device
ProductionProposed Part #
FallTech
Built By Whom
Retraction Tension
0% Extracted
Retraction Tension
20% Extracted
Retraction Tension
40% Extracted
Retraction Tension
60% Extracted
Retraction Tension
80% Extracted
Retraction Tension
100% Extracted
Retraction Tension
0% Extracted
Retraction Tension
20% Extracted
Retraction Tension
40% Extracted
Retraction Tension
60% Extracted
Retraction Tension
80% Extracted
Retraction Tension
100% Extracted
Pass
1.25 Lbf - 25 Lbf
< 24" Extended
ANSI Z359.14-2014
4.2.6 1.25 Lbf - 25 Lbf
< 24" Extended7.6 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended10.2 lbF
8.2 lbF Pass
7.4 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended8.2 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended9.2 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended4.8 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended5.6 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended6.2 lbF Pass
ANSI Z359.14-2014
4.2.6
1.25 Lbf - 25 Lbf
< 24" Extended5.0 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended6.0 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended6.4 lbF Pass
1.25 Lbf - 25 Lbf
< 24" Extended
Certificate# TL-594 Testing
FLT-08 Rev. G
Page 9 of 26
Report Prepared For
Initiated By
Base Part#
Proposed Part#
Test Request#
ANSI Z359.14-2014 4.2.6
ANSI Z359.14-2014 4.2.S
ANSI Z359.14-2014 4.2.S
ANSI Z359.14-2014 4.2.S
'Witnessed by
·~ v ACCREDITED Certificate# TL·594 Testing
FallTech
ANSI 2359.14-2014
FallTech Testing Laboratory 1306 S. Alameda Street,
Compton, CA 90221-4803 Tel : (323) 752-0060
www.falltech .com
4.3.1, 4.3.3, 4 .2 .1, Dan Redden Test Specification
4.3.4, 4.2.8.1, 4.2.8.2, 4 .2.8.3, 4.2.5, 4.2.6,
7281 Description 60' Cable 3-Way Self Retracting Device
N/A Built By Whom Production BOM No
PC-0865 Date Received 617/2016 Date Complete 6/29/2016
Retraction Tension 1.25 Lbf - 25 Lbf 4.4 lbF
0% Extracted ~ 24" Extended
Retraction Tension 1.25 Lbf - 25 Lbf 6.2 lbF
20% Extracted ~ 24" Extended
Retraction Tension 1.25 Lbf - 25 Lbf 6.2 lbF
40% Extracted ~ 24" Extended
Retraction Tension 1.25 Lbf - 25 Lbf 7.6 lbF
60% Extracted ~ 24" Extended
Retraction Tension 1.25 Lbf - 25 Lbf 7.8 lbF
80% Extracted ~ 24" Extended
Retraction Tension 1.25 Lbf- 25 Lbf 7.2 lbF
100% Extracted ~ 24" Extended
!'.3,000 Lbf 3084.0 lbF Static Strength
for.:'. 60 Seconds
!'.3,000 Lbf 3062.9 lbF Static Strength
for.:'. 60 Seconds
Static Strength !'.3,000 Lbf
3068.7 lbF for.:'. 60 Seconds
Date
This laboratory Is accredted In accordance with the recogiized lrlernaUonal Standard ISO/IEC 17025:2005. Tlis accred~ation demonstrates tectnical competence for a defined scope and the operation or a
laboratory q111lity managemerl system (rerer to the joirl ISO-ILAC-IAF Commt.nlque dated Jar<Jary 2009). Fal/Tec/1 Testing LaborD!ory allows for a +/- 5% tolerance oo dynamic and static •treflf/f/1tesl re•ub.
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
7/8/2016
&/3o /It-
FLT-08 Rev. G
Page 10 of 26