*** SAFETY PAYS ***
*** SUPPORT VALUE ENGINEERING - IT PAYS ***
DE
SIG
NE
D B
Y:
DR
AW
N B
Y:
CH
EC
KE
D B
Y:
PR
OJE
CT E
NGIN
EE
R/A
RC
HIT
EC
T
DA
TE
DR
AWIN
G C
OD
E:
SC
ALE:
DA
TE:
SY
MB
OL
RE
VISIO
NS
DE
SC
RIP
TIO
NA
PP
R.
DA
TE
OF ENGINEERS
US ARMY CORPS
CO
RP
S O
F E
NGIN
EE
RS
U.S.
AR
MY E
NGIN
EE
R DIS
TRIC
T
LOUISVILLE DISTRICT
SHEET REF NUMBER:
SHEET OF
1 2 3 4 5 6 7 98
F
E
D
A
B
C
05-MAR-2013
353449_OMS_S-001xxx.dgn
MA
RC
H 2
013
LO
UIS
VIL
LE DIS
TRIC
T
C.
GR
AS
S
PN
67659
F-1
71-4
0-1
76
FY13
A.
MC
CO
Y
E. F
RY
R. S
MIT
HS
HE
RID
AN A
RM
Y R
ES
ER
VE C
EN
TE
R (
AR
C)
SH
ERID
AN, IL
LIN
OIS
OMS
S-001
GE
NE
RA
L N
OT
ES
OM
S B
UIL
DIN
G
STRUCTURAL ABBREVIATIONS GENERAL NOTES
DESCRIPTION
DESIGN NOTES
SYMBOL SYMBOL DESCRIPTION
HCA HEADED CONCRETE ANCHOR
MLC MILITARY LOAD CLASSIFICATION
TOS TOP OF STEEL
IAW IN ACCORDANCE WITH
AB
AFF
AHR
APPROX
ARCH
BD
BOC
BOS
BRG
CFS
CJ
CL
CLR
CMU CONCRETE MASONRY UNIT
CLEAR
CENTER LINE
CONSTRUCTION JOINT
COLD-FORMED STEEL
BEARING
BOTTOM OF STEEL
BOTTOM OF CONCRETE
BAR DIAMETER
ARCHITECTURAL
APPROXIMATELY
ANCHOR
ABOVE FINISHED FLOOR
ANCHOR BOLT
COL
CONN
CONC
CONT
DCJ
DIA, Ø
DN
DP
EA
DWG(S)
EF
EJ
ELEC
ELEV ELEVATION
ELECTRICAL
EXPANSION JOINT
EACH FACE
DRAWING(S)
EACH
DEPRESSED SLAB
DOWN
DIAMETER
DOWELED CONSTRUCTION JOINT
CONTINUOUS
CONCRETE
CONNECTION
COLUMN
HS
HORIZ
GALV
EQ
EW
FFE
FOM
FTG
GA
HIGH STRENGTH
HORIZONTAL
GALVANIZED
GAGE
FOOTING
FACE OF MASONRY
FINISHED FLOOR ELEVATION
EACH WAY
EQUAL
PLF
PL
PJF
PEMB
OPP
OC
NO
NIC
MOW
MIN
MFR
MECH MECHANICAL
MANUFACTURER
MINIMUM
MIDDLE OF WALL
NOT IN CONTRACT
ON CENTER
NUMBER
OPPOSITE
PRE-ENGINEERED METAL BUILDING
PREMOLDED JOINT FILLER
POUNDS PER LINEAR FOOT
PLATE
TORO
TOF
TOM
TOC
TOBB
T&B
SJ
SIM
RO
SF
ROUGH OPENING
STEPPED FOOTING
SIMILAR
SAWED (CONTRACTION) JOINT
TOP AND BOTTOM
TOP OF BOND BEAM
TOP OF CONCRETE
TOP OF FOOTING
TOP OF MASONRY
TOP OF ROUGH OPENING
UON
VERT
UNLESS OTHERWISE NOTED
VERTICAL
LB(S)
KIP (k)
POUND(S)
1000 LBS
MAX MAXIMUM
PL
REINF REINFORCEMENT
TDS TURNDOWN SLAB
WWR WELDED WIRE REINFORCEMENT
WF WALL FOOTING
TS
TYP
THICKENED SLAB
TYPICAL
METAL BUILDING SYSTEMS MANUAL 2006J)
MASONRY STRUCTURES" ACI 530-08 "BUILDING CODE REQUIREMENTS FORI)
BUILDINGS UFC 4-010-01 DoD MINIMUM ANTITERRORISM FORH)
W/ CHANGE 1 UFC 3-310-04: SEISMIC DESIGN FOR BUILDINGSG)
UFC 3-301-01 STRUCTURAL ENGINEERING W/ CHANGE 2F)
W/ CHANGE 2 UFC 1-200-01 GENERAL BUILDING REQUIREMENTSE)
STRUCTURAL CONCRETE" ACI 318-08, "BUILDING CODE REQUIREMENTS FORD)
BUILDINGS" DATED MARCH 1, 2005 AISC "SPECIFICATION FOR STRUCTURAL STEELC)
AND OTHER STRUCTURES ASCE 7-05, MINIMUM DESIGN LOADS FOR BUILDINGSB)
2009 INTERNATIONAL BUILDING CODEA)
THE FOLLOWING CODES AND SPECIFICATIONS:STRUCTURAL DESIGN SHALL BE IN ACCORDANCE WITH1.
P2 #
353449
497 616
65 KIPSVEHICLE AXLE LOAD123VEHICLE DESIGN MLCBCRANE CLASSIFICATION20 FTHOOK HEIGHT10 TONSCRANE CAPACITY
H) BUILDING USE
SEE PEMB NOTE 5 ON OMS S-002WIND/SEISMIC DEFLECTION
HORIZONTAL:
L/180TOTAL LOAD DEFLECTIONL/240LIVE LOAD DEFLECTION
ROOF FRAMING
VERTICAL:
G) DEFLECTION CRITERIA FOR PEMB DESIGN
SEE PEMB NOTE 2 ON OMS S-002F) COLLATERAL DEAD LOAD
PER PEMBSEISMIC RESPONSE COEFFICIENTPER PEMBDESIGN BASE SHEARPER PEMBANALYSIS PROCEDUREPER PEMBRESPONSE MODIFICATION FACTORPER PEMBBASIC SEISMIC-FORCE-RESISTING SYSTEM
BSEISMIC DESIGN CATEGORYDSITE CLASS0.088gSPECTRAL RESPONSE COEFFICIENT, Sd10.158gSPECTRAL RESPONSE COEFFICIENT, Sds0.055gMAPPED SPECTRAL RESPONSE ACCEL., S10.148gMAPPED SPECTRAL RESPONSE ACCEL., Ss1.0SEISMIC IMPORTANCE FACTOR, IeIIOCCUPANCY CATEGORY
E) SEISMIC LOADS ARE IAW ASCE 7-05:
SEE OMS S-003COMPONENTS AND CLADDING+/-0.18INTERNAL PRESSURE COEFF., GCpi0.85GUST EFFECT FACTOR, GDWIND EXPOSURE CATEGORY1.0WIND LOAD IMPORTANCE FACTOR, IwIIOCCUPANCY CATEGORY90 MPHBASIC WIND SPEED, V
D) WIND LOADS ARE IAW ASCE 7-05:
20 PSFFLAT-ROOF SNOW LOAD, Pf1.0SNOW LOAD IMPORTANCE FACTOR, Is1.0THERMAL FACTOR, Ct0.9SNOW EXPOSURE FACTOR, Ce25 PSFGROUND SNOW LOAD, Pg
C) SNOW LOADS ARE IAW ASCE 7-05
15 PSF PARTITION LOAD IS INCLUDED IN LIVE LOADS.DESIGN OF THIS STRUCTURE. WHERE APPLICABLE, A NOTE: LIVE LOAD REDUCTION SHALL NOT USED IN THE
65 PSFTRAINING ROOMS 20 PSF MIN.ROOF300 PSFREPAIR BAY / MAINTENANCE AREA125 PSFMECHANICAL / ELECTRICAL ROOMS100 PSFLOBBIES125 PSFLIGHT STORAGE ROOMS250 PSFHEAVY STORAGE ROOMS100 PSFFIRST FLOOR SLAB-ON-GRADE UON 80 PSFCORRIDORS
B) LIVE LOADS:
TOTAL PER PEMB MANUFACTURER2.0 PSFMISCELLANEOUS6.0 PSFMECHANICAL AND ELECTRICAL2.0 PSFCEILING3.0 PSFMETAL DECK (1.5B 18GA)1.0 PSFSTANDING SEAM METAL ROOF1.0 PSF(6") RIGID INSULATION
ROOF:
LEAN-TO RAFTER PORTION
TOTAL PER PEMB MANUFACTURER2.0 PSFMISCELLANEOUS6.0 PSFMECHANICAL AND ELECTRICAL3.0 PSFMETAL DECK (1.5B 18GA)1.0 PSFSTANDING SEAM METAL ROOF1.0 PSF(6)" RIGID INSULATION
ROOF:
PRIMARY RIGID FRAME PORTION
A) DEAD LOADS:
DESIGN LOAD CRITERIA3.
FINAL DESIGN LOADS BY PEMB MANUFACTURER. MINIMUM DESIGN LOADS TO BE USED BY PEMB MANUFACTURER. BY UFC 1-200-01 AND UFC 3-301-01. PROVIDED DEAD LOADS ARE IN ACCORDANCE WITH (IAW): IBC 2009 AND ASCE 7-05 AS MODIFIED2.
DB
B-R
EA
DY T
O A
DV
ER
TIS
E
OVERHEAD AND UNDERGROUND, FOR THE DURATION OF CONSTRUCTION.15. THE CONTRACTOR SHALL LOCATE AND PROTECT ALL EXISTING UTILITIES,
BUILDING CODE.FOR BUILDINGS AND OTHER STRUCTURES AND IBC 2009, INTERNATIONAL RESISTING SYSTEMS AS REQUIRED BY ASCE 7-05, MINIMUM DESIGN LOADS
14. THE CONTRACTOR SHALL PROVIDE SPECIAL INSPECTIONS FOR SEISMIC
COMPLETION OF THIS WORK.DISCREPANCIES OR UNDOCUMENTED CONDITIONS THAT MAY EFFECT THE
13. THE CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER OF ANY
MECHANICAL OR ELECTRICAL EQUIPMENT.ANY INSERTS, HANGERS, PIPE SLEEVES OR HOLES REQUIRED FOR RESPONSIBLE FOR COORDINATING THE LOCATION AND PLACEMENT OF UNLESS OTHERWISE SHOWN OR NOTED, THE CONTRACTOR SHALL BE 12.
OF THE PROJECT.SHALL REMAIN THE PROPERTY OF THE CONTRACTOR AFTER COMPLETION SHEETING, TEMPORARY BRACING, GUYS OR TIEDOWNS. SUCH MATERIAL CONSTRUCTION. THIS INCLUDES THE ADDITION OF NECESSARY SHORING, SAFETY OF THE BUILDING, ITS COMPONENTS AND OCCUPANTS DURING DETERMINE ERECTION PROCEDURES AND SEQUENCE TO ENSURE THE COMPLETED. IT IS THE CONTRACTOR’S SOLE RESPONSIBILITY TO ONLY AFTER THE STRUCTURAL WORK CONTAINED IN THE DRAWINGS IS THE STRUCTURE IS DESIGNED TO BE SELF SUPPORTING AND STABLE 11.
OF LOADING RESTRICTIONS.CONTRACTOR WILL ENSURE THAT ALL SUBCONTRACTORS ARE INFORMED MATERIALS ON POURED OR ERECTED FLOOR/ROOFS. GENERAL OR ERECTED FLOOR OR ROOF. DO NOT STORE OR STACK CONSTRUCTION MANUFACTURER. AVOID IMPACT WHEN PLACING MATERIALS ON POURED CONTRACTOR SHALL COORDINATE LOADING RESTRICTIONS WITH PEMB 10.
ROOF.IMPACT WHEN PLACING MATERIALS ON POURED OR ERECTED FLOOR OR SUBCONTRACTORS ARE INFORMED OF LOADING RESTRICTIONS. AVOID LOAD. GENERAL CONTRACTOR WILL ENSURE THAT ALL ERECTED FLOOR/ROOFS IN EXCESS OF 80 PERCENT OF THE DESIGN LIVE DO NOT STORE OR STACK CONSTRUCTION MATERIALS ON POURED OR 9.
SUPPORT PLAN FOR SLABS AND FRAMING PRIOR TO COMMENCING WORK.OBTAIN DESIGNER OF RECORD APPROVAL ON PROPOSED EQUIPMENT AND FRAMING HAVE NOT BEEN DESIGNED FOR EQUIPMENT LOADS. CRANES, PERSONNEL LIFTS OR OTHER ERECTION EQUIPMENT. THE SLAB DO NOT LOAD THE SLAB-ON-GRADE OR SUPPORTED SLAB WITH ERECTION 8.
RESPONSIBILITY OF THE CONTRACTOR.WELL AS SUPERVISION OF THE WORK, SHALL BE THE SOLE CONSTRUCTION TECHNIQUES, MEANS, METHODS, AND SEQUENCES, AS 7.
DRAWINGS UNDER ANY CIRCUMSTANCE.REPRODUCTION OF CONTRACT DRAWINGS SHALL NOT BE USED AS SHOP 6.
DRAWINGS FOR ACTUAL DATUM ELEVATION.THE FINISHED FIRST FLOOR ELEVATION DATUM IS [100’-0"]. SEE CIVIL ELEVATIONS ON THE STRUCTURAL DRAWINGS ARE DENOTED AS [X’-X"], 5.
AGAINST WIND AND/OR CONSTRUCTION LOADS.DURING CONSTRUCTION. BRACE ALL WALLS DURING CONSTRUCTION CONNECTIONS ARE FULLY MADE, AS NECESSARY, TO ENSURE STABILITY COMPONENTS UNTIL ALL COMPONENTS ARE ERECTED AND ALL PROVIDE TEMPORARY BRACING AND SHORING OF THE STRUCTURE AND 4.
REFERENCED.ANOTHER CONDITION WHERE THE DETAIL IS SPECIFICALLY INDICATED OR TITLES OR FROM THE SIMILARITY OF A CONSTRUCTION CONDITION TO DETERMINE APPLICABILITY OF TYPICAL DETAILS FROM DESCRIPTIVE CASES WHERE THE NATURE OF THE CONSTRUCTION REQUIRES THEIR USE. SPECIFICALLY INDICATED OR REFERENCED, BUT ALSO IN ALL OTHER DETAILS ENTITLED OR NOTED AS "TYPICAL" APPLY NOT ONLY WHERE 3.
THAT WILL BE AFFECTED.TO THE CONTRACTING OFFICER PRIOR TO BEGINNING WORK IN AREAS REPORT DISCREPANCIES IN DIMENSIONS BETWEEN DIFFERENT DRAWINGS 2.
HANGERS, AND ANCHORS.NOT LIMITED TO, THE REQUIREMENTS FOR SLEEVES, INSERTS, HOLES, DRAWINGS. COORDINATE THE WORK OF OTHER TRADES INCLUDING, BUT USE STRUCTURAL DRAWINGS IN CONJUNCTION WITH ALL OTHER 1.
W912
QR-1
3-R
0036
MA
RC
H 2
013
*** SAFETY PAYS ***
*** SUPPORT VALUE ENGINEERING - IT PAYS ***
DE
SIG
NE
D B
Y:
DR
AW
N B
Y:
CH
EC
KE
D B
Y:
PR
OJE
CT E
NGIN
EE
R/A
RC
HIT
EC
T
DA
TE
DR
AWIN
G C
OD
E:
SC
ALE:
DA
TE:
SY
MB
OL
RE
VISIO
NS
DE
SC
RIP
TIO
NA
PP
R.
DA
TE
OF ENGINEERS
US ARMY CORPS
CO
RP
S O
F E
NGIN
EE
RS
U.S.
AR
MY E
NGIN
EE
R DIS
TRIC
T
LOUISVILLE DISTRICT
SHEET REF NUMBER:
SHEET OF
1 2 3 4 5 6 7 98
F
E
D
A
B
C
05-MAR-2013
353449_OMS_S-002xxx.dgn
MA
RC
H 2
013
LO
UIS
VIL
LE DIS
TRIC
T
C.
GR
AS
S
PN
67659
F-1
71-4
0-1
76
FY13
A.
MC
CO
Y
E. F
RY
R. S
MIT
HS
HE
RID
AN A
RM
Y R
ES
ER
VE C
EN
TE
R (
AR
C)
SH
ERID
AN, IL
LIN
OIS
OMS
S-002
GE
NE
RA
L N
OT
ES
OM
S B
UIL
DIN
G
PRE-ENGINEERED METAL BUILDING
SPECIAL INSPECTIONS
STEEL DECK
CONCRETE CONSTRUCTION NOTESSTEEL NOTESFOUNDATION NOTES
OPENING UP TO 6’-0"........................... L6 x 3-1/2 x 3/8
OPENING UP TO 3’-0"........................... L3-1/2 x 3-1/2 x 3/8
LOOSE BRICK VENEER LINTEL MINIMUM SIZE SHALL BE AS FOLLOWS:3.
PROVIDE 8" BEARING ON EACH END OF STEEL LINTEL, MINIMUM.2.
ALL LOOSE BRICK LINTELS SHALL BE HOT DIP GALVANIZED.1.
ADHESIVE ANCHORS
NON-SHRINK GROUT NOTES
LOOSE BRICK LINTEL NOTES
MASONRY CONSTRUCTION NOTES
P2 #
353449
SHALL BE FILLED WITH GROUT.ALL MASONRY BOND BEAMS, LINTELS, AND BLOCKS WITH EMBEDDED ANCHOR BOLTS 12.
SHALL BE SHOWN ON THE SHOP DRAWINGS.THE LOCATIONS OF ALL OPENINGS, BOND AND LINTEL BEAMS, AND THE REINFORCEMENT 11.
SCHEDULES.SPACING AS VERTICAL WALL REINFORCEMENT. LAP WALL REINFORCEMENT PER PROVIDE DOWEL REINFORCEMENT FROM WALLS INTO FOUNDATION OF SAME SIZE AND 10.
CELLS. USE NONMETALLIC BAR POSITIONERS.UNLESS OTHERWISE NOTED OR DETAILED, CENTER WALL REINFORCEMENT IN BLOCK 9.
ALUMINUM AND STEEL.ALUMINUM-CEMENT CHEMICAL REACTION OR ELECTROLYTIC REACTION BETWEEN GROUT, OR MORTAR, UNLESS EFFECTIVELY COATED OR COVERED TO PREVENT ALUMINUM CONDUITS, PIPES, AND ACCESSORIES SHALL NOT BE EMBEDDED IN MASONRY 8.
PVC SLEEVES OR CORED HOLES UNLESS OTHERWISE INDICATED ON THE DRAWINGS.PLACE PIPES AND CONDUITS PASSING HORIZONTALLY THROUGH MASONRY IN STEEL OR 7.
BEYOND THE JAMB ON EACH SIDE.IMMEDIATELY ABOVE AND BELOW ALL OPENINGS, EXTENDING A MINIMUM OF 24 INCHES AT THE TOP OF ALL FOUNDATIONS, AT FLOORS AND ROOF AND IN THE TWO JOINTS BEAMS AT A MAXIMUM OF 8 FEET ON CENTER. ADDITIONALLY LOCATE REINFORCEMENT LOCATE JOINT REINFORCEMENT 16 INCHES ON CENTER VERTICALLY AND PROVIDE BOND 6.
FABRICATE REINFORCING BARS WHICH ARE INDICATED TO BE BENT OR HOOKED.60 AND SHALL HAVE FABRICATION TOLERANCES IN ACCORDANCE WITH ACI SP-66. SHOP REINFORCEMENT SHALL BE DEFORMED BARS CONFORMING TO ASTM A615/A615M, GRADE 5.
SHALL ATTAIN A MINIMUM 28-DAY COMPRESSIVE STRENGTH OF 2000 PSI.GROUT SHALL CONFORM TO ASTM C476 AND SHALL NOT CONTAIN ADMIXTURES. GROUT 4.
WITH MEDIUM OR NORMAL WEIGHT AGGREGATE.CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90 AND BE MANUFACTURED 3.
STRENGTH OF CONCRETE MASONRY UNITS SHALL BE A MINIMUM OF 2150 PSI.DESIGN MASONRY ASSEMBLAGE STRENGTH, f’m = 1500 PSI. NET AREA COMPRESSIVE 2.
"SPECIFICATION FOR MASONRY STRUCTURES" (ACI 530.1-08/ASCE 7-05/TMS 602-05).REQUIREMENTS FOR MASONRY STRUCTURES" (ACI 530-08/ASCE 7-05/TMS 402-05) AND ALL MASONRY CONSTRUCTION SHALL BE IN ACCORDANCE WITH "BUILDING CODE 1.
CONDUIT.VAPOR BARRIER OR WATERPROOFING SYSTEM SHALL BE SEALED TO THE PIPE OR AT ALL PENETRATIONS THROUGH FLOOR SLABS AND FOUNDATION WALLS THE 19.
CONTRACTING OFFICER FOR APPROVAL.PRIOR TO PLACEMENT OF CONCRETE, SUBMIT JOINT LAYOUTS TO THE 18.
FINISHES, FLOOR DEPRESSIONS, AND CURBS.SEE ARCHITECTURAL DRAWINGS FOR TYPE AND LOCATION OF ALL FLOOR 17.
OTHERWISE NOTED ON DRAWINGS.ALL DOWELS SHALL MATCH SIZE AND NUMBER OF MAIN REINFORCING UNLESS 16.
TO ENGINEER OF RECORD FOR REVIEW.SPACING. CONTRACTOR SHALL SUBMIT SLAB-ON-GRADE JOINT SHOP DRAWINGS SLAB-ON-GRADE CONSTRUCTION SEQUENCING. SEE PLANS FOR SLAB JOINT CONTRACTOR SHALL COORDINATE SLAB-ON-GRADE JOINT REQUIREMENTS WITH REPRESENT ALL OF THE JOINTS REQUIRED FOR SLAB-ON-GRADE CONSTRUCTION. CONCRETE SLAB-ON-GRADE JOINTS INDICATED ARE DIAGRAMMATIC AND DO NOT 15.
REACTION AND ELECTROLYTIC ACTION BETWEEN ALUMINUM AND STEEL.EFFECTIVELY COATED OR COVERED TO PREVENT ALUMINUM-CONCRETE ALUMINUM SHALL NOT BE PLACED IN DIRECT CONTACT WITH CONCRETE UNLESS 14.
ALL EXPOSED CONCRETE EDGES SHALL BE CHAMFERED 3/4" OR AS INDICATED.13.
REINFORCEMENT.REPRESENTATIVE HAS INSPECTED ALL EMBEDDED WORK, INCLUDING NO CONCRETE SHALL BE PLACED UNTIL THE COR OR THE COR’S DESIGNATED 12.
INDICATED.SHALL NOT BE CUT TO FACILITATE PLACEMENT OF EMBEDDED ITEMS, UNLESS OTHER EMBEDDED ITEMS UNLESS OTHERWISE INDICATED. REINFORCEMENT REINFORCING STEEL SHALL BE SPREAD AT SLEEVES, ANCHORS, RECESSES AND 11.
PLACEMENT.AND MAINTAINED SECURELY IN PLACE PRIOR TO AND DURING CONCRETE ALL EMBEDDED ITEMS SHALL BE PROPERLY PLACED, ACCURATELY POSITIONED 10.
VERTICAL SURFACES, UNO.PROVIDE 1/2" THICK JOINT FILLER MATERIAL WHERE SLABS ON GRADE ABUT 9.
REQUIREMENTS OF ACI 318.NOTED. STIRRUPS, TIES, AND 180 DEGREE HOOKS SHALL CONFORM TO THE DEGREE HOOK A MINIMUM OF 12 BAR DIAMETERS IN LENGTH, UNLESS OTHERWISE CONCRETE REINFORCING STEEL MARKED STANDARD HOOK SHALL HAVE A 90 8.
1"C. SLABS AND WALLS 2"B. CONCRETE EXPOSED TO EARTH OR WEATHER 3"A. CONCRETE DEPOSITED AGAINST THE GROUND
ACI 301 AND ACI 318.NO CASE SHALL REINFORCEMENT COVER BE LESS THAN THE REQUIREMENTS OF MINIMUM CONCRETE COVER FOR REINFORCING STEEL SHALL BE AS INDICATED. IN 7.
WITH THE REQUIREMENTS OF ACI 318.INDICATED. CONTINUOUS REINFORCING STEEL SHALL BE LAPPED IN ACCORDANCE CONCRETE REINFORCING STEEL SHALL BE CONTINUOUS UNLESS OTHERWISE 6.
TIED AND LAPPED ONE FULL MESH SPACING.PROVIDE SHEET-TYPE WELDED WIRE REINFORCEMENT. SHEET LAPS SHALL BE WELDED WIRE REINFORCEMENT SHALL CONFORM TO ASTM A185 OR ASTM A497. 5.
REINFORCING BARS WHICH ARE INDICATED TO BE BENT OR HOOKED.FABRICATION TOLERANCES IN ACCORDANCE WITH ACI SP-66. SHOP FABRICATE BARS SHALL CONFORM WITH ASTM A706/A706M, GRADE 60. ALL BARS SHALL HAVE SPECIFICATIONS ALLOW, EXCEPT WHERE BARS ARE TO BE WELDED. WELDED ASTM A706/A706M, GRADE 60. ASTM A615/A615M SHALL BE PERMITTED AS CONCRETE REINFORCING STEEL SHALL BE DEFORMED BARS CONFORMING TO 4.
CONCRETE DENSITY SHALL BE NORMAL WEIGHT.3.
HAVE A MINIMUM 28-DAY COMPRESSIVE STRENGTH (f’c) OF 4000 PSI.STRENGTH (f’c) OF 4000 PSI FOR ALL STRUCTURAL MEMBERS, FOOTINGS SHALL ALL CAST-IN-PLACE CONCRETE SHALL ATTAIN MINIMUM 28-DAY COMPRESSIVE 2.
CONTRACTOR SHALL BE IN ACCORDANCE WITH ACI 318-08.CONCRETE (ACI 301-08). ALL CONCRETE DESIGN PERFORMED BY THE OF THE AMERICAN CONCRETE INSTITUTE (ACI) SPECIFICATIONS FOR STRUCTURAL ALL CONCRETE CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE PROVISIONS 1.
EXISTING REINFORCEMENT IS ENCOUNTERED DURING THE DRILLING PROCESS.
CONCRETE. CONTACT ENGINEER WHERE NOT DRILL THROUGH REBAR IN EXISTING
ENCOUNTERING EXISTING REINFORCING DURING DRILLING - CONTRACTOR SHALL 3.
ADHESIVE PER THE MANUFACTURER’S RECOMMENDATION.
HOLE OF CONCRETE DUST WITH BRUSH AND OIL-FREE COMPRESSED AIR. INJECT
SIZE SPECIFIED. THOROUGHLY CLEAN PRODUCT MANUFACTURER FOR THE DOWEL
PROVIDE DRILLED HOLES OF DIAMETER AND DEPTH RECOMMENDED BY THE 2.
RECOMMENDATIONS.MANUFACTURER’S PRINTED LITERATURE AND
ADHESIVE ANCHOR SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH 1.
8000 PSI.
DECKING IS PLACED. GROUT SHALL HAVE A MINIUM COMPRESSIVE STRENGTH OF
MUST BE PLACED IMMEDIATELY AFTER COLUMN IS PLUMB, AND BEFORE ANY
ACCORDANCE WITH MANUFACTURER’S WRITTEN RECOMMENDATIONS. GROUT
WATER PRIOR TO PLACING GROUT. GROUT PRODUCT SHALL BE INSTALLED IN
SHALL BE FREE FROM DUST, DEBRIS, OR GROUT. SURFACE OF EXISTING CONCRETE
NON-SHRINK GROUT SHALL BE HIGH STRENGTH, NON-FERROUS, NON-SHRINK 1.
CONTRACTING OFFICER’S SATISFACTION.CQC STAFF, WHO HAS DEMONSTRATED COMPETENCE TO THE UNDER THE
A SPECIAL INSPECTOR IS A QUALIFIED PERSON, EXCLUSIVE OF PERSONNEL INCLUDED 6.
(CQC) PLAN.INCLUDE SPECIAL INSPECTIONS REQUIREMENTS IN CONTRACTOR’S QUALITY CONTROL 5.
INSPECTIONS FOR SEISMIC RESISTANCE SHALL BE AS PER IBC 2009, SECTION 1707.4.
1704.4.AND TABLE INSPECTION OF CONCRETE CONSTRUCTION SHALL BE AS PER IBC 2009, SECTION 1704.4. 3.
1704.3.TABLE INSPECTION OF STEEL CONSTRUCTION SHALL BE AS PER IBC 2009, SECTION 1704.3. AND 2.
INSPECTION OF FABRICATORS SHALL BE AS PER IBC 2009, SECTION 1704.2.1.
LOADS MAY REQUIRE SPECIAL EVALUATION.NOTIFY DECK MANUFACTURER OF ANY LOADING CONDITION OVER 200 PSF.THESE 7.
DECK ENDS SHALL BEAR A MINIMUM OF 2" AT END SUPPORTS.METAL ROOF DECK SHALL HAVE NO LESS THAN THREE SPANS PER PANEL UNO 6.
AS DESIGNED BY PEMB MANUFACTURER).METAL DECK SHALL BE MINIMUM 1 1/2" DEEP, GALVANIZED, WIDE RIB DECK (TYPE - 5.
MANUFACTURER’S SPECIFICATIONS.MEMBERS AS INDICATED ON STRUCTURAL SECTIONS AND DETAILS AND IAW THE SPECIFICATIONS AND ERECTION LAYOUTS AND CONNECTED TO SUPPORTING METAL DECK SHALL BE ERECTED IN ACCORDANCE WITH THE MANUFACTURER’S 4.
STRENGTH OF 33 KSI AS PER THE LATEST EDITION OF THE STEEL DECK INSTITUTE.NEW METAL ROOF DECK SHALL BE ASTM A653 HAVING A MINIMUM YIELD 3.
580 CLASS 90.THE ROOF SYSTEM MUST ALSO RESIST UPLIFT PRESSURES PRESCRIBED BY UL 2.
PERFORMED BY A REGISTERED PROFESSIONAL ENGINEER.THE CONTRACTOR AS PART OF THE METAL ROOF SYSTEM. DESIGN SHALL BE CONNECTIONS SUPPORTED BY COLD FORMED FRAMING SHALL BE DESIGNED BY ALL METAL ROOF DECK SHALL BE IAW SDI. METAL ROOF DECK AND ASSOCIATED 1.
FABRICATION AND CONSTRUCTION.SUBMIT STRUCTURAL STEEL SHOP DRAWINGS FOR APPROVAL PRIOR TO 11.
DRAWINGS PRIOR TO FABRICATION.INDICATED ON APPROVED SUBMITTALS, AND AS SPECIFICALLY APPROVED ON SHOP EXCEPT AS DETAILED ON THE DRAWINGS, PERMITTED IN THE SPECIFICATIONS, AS SHOP AND FIELD SPLICES OF STRUCTURAL STEEL MEMBERS ARE PROHIBITED 10.
CALCULATIONS FOR ANY ALTERNATE DETAILS AND MEMBER SPLICES.THE CONTRACTOR SHALL SUBMIT FOR APPROVAL DRAWINGS AND DESIGN 9.
SPECIFIED.MANUAL", 13TH EDITION, FOR THE BEAM SIZE, SPAN, AND GRADE OF STEEL INDICATED IN THE LOAD TABLES OF PART 3 OF THE AISC "STEEL CONSTRUCTION BE DESIGNED FOR 50 PERCENT OF THE MAXIMUM TOTAL UNIFORM LOAD AS CONDITIONS WHERE REACTIONS ARE NOT INDICATED, SHEAR CONNECTIONS SHALL SHALL BE DESIGNED FOR THE SERVICE REACTIONS GIVEN IN DRAWING SET. FOR SHEAR CONNECTIONS FOR BEAMS SUPPORTING FLOOR AND ROOF GRAVITY LOADS 8.
CONNECTION DESIGN IS DELEGATED TO THE CONTRACTOR.7.
CONNECTIONS, THREADS INCLUDED IN SHEAR PLANE.ALL FIELD-BOLTED SHEAR CONNECTIONS SHALL BE SNUG TIGHT BEARING-TYPE 6.
IN THE FIELD.SHALL NOT BE CUT OR ENLARGED BY FLAME CUTTING PERMITTED. BOLT HOLES
FIELD CUTTING OF STRUCTURAL STEEL MEMBERS BY ANY TRADE SHALL NOT BE 5.
FOR THE CONNECTION LOADS. HIGH-STRENGTH BOLTS WITH HARDENED CARBON STEEL WASHERS AS REQUIRED ALL BOLTED CONNECTIONS, UNLESS OTHERWISE NOTED, SHALL USE 4.
REVIEW BY THE COR�S REPRESENTATIVE.NOTED. CURRENT AWS CERTIFICATIONS SHALL BE AVAILABLE AT THE JOB SITE FOR CONFORM TO AWS STANDARDS. USE E70XX ELECTRODES UNLESS OTHERWISE ALL SHOP AND FIELD WELDING SHALL BE BY CERTIFIED WELDERS AND SHALL 3.
ASTM A36/ A36MI. THREADED ROD
ASTM F1554, GRADE 36H. ANCHOR RODS w/ NUT AND WASHER
ASTM F1554, GRADE 36G. HOOKED ANCHOR RODS
ASTM A325F. HIGH STRENGTH BOLTS
ASTM A36/ A36ME. PLATES AND ANGLES
ASTM A36/ A36MD. CHANNELS AND S-SHAPES
ASTM A992, GRADE 50C. WIDE-FLANGE SHAPES AND TEES
ASTM 500, GRADE B, Fy=42 KSIB. ROUND HSS
ASTM 500, GRADE B, Fy=46 KSIA. SQUARE AND RECTANGULAR HSS
THE ABOVE-LISTED AISC SPECIFICATION AND THE FOLLOWING:UNLESS OTHERWISE NOTED, STRUCTURAL STEEL SHALL BE IN ACCORDANCE WITH 2.
STANDARD PRACTICE FOR BUILDINGS AND BRIDGES", DATED MARCH 18, 2005.STRUCTURAL STEEL BUILDINGS" DATED MARCH 9, 2005 AND THE AISC "CODE OF ONNECTIONS SHALL BE IN ACCORDANCE WITH THE AISC "SPECIFICATION FOR FABRICATION AND ERECTION OF STRUCTURAL STEEL AND DESIGN OF C1.
00 0006 EARTHWORK SPEC.WITH STRUCTURAL FILL IN ACCORDANCE WITH 31 EXCAVATED AND REPLACED
UNDOCUMENTED FILL ENCOUNTERED IN STRUCTURAL AREAS SHALL BE 13.
EXISTING FOUNDATIONS, UNO.OR BRACING REQUIRED. DO NOT UNDERCUT RESPONSIBLE FOR ANY SHORING
PROTECT EXISTING FOUNDATION SYSTEMS. THE CONTRACTOR IS 12.
DATED JULY 2012.REPORT PREPARED BY US ARMY CORPS OF ENGINEERS, LOUISVILLE DISTRICT,
THE GEOTECHNICAL INVESTIGATION RECOMMENDATIONS CONTAINED IN CONTRACTOR SHALL DESIGN THE FOUNDATIONS BASED ON THE 11.
ADEQUATE FOR FOUNDATION SUPPORT.GEOTECHNICAL ENGINEER TO VERIFY THE EXPOSED BEARING SURFACE IS IS
APPROVED BY THE CONTRACTOR’S PROFESSIONAL BE INSPECTED AND PRIOR TO PLACEMENT OF CONCRETE, ALL FOUNDATION EXCAVATION SHALL 10.
WELDED WIRE REINFORCING.PERMITTED TO BE PLACED BETWEEN TWO LAYERS OF SLABS ON GRADE. IT IS
RADIANT FLOOR PIPING SHALL NOT BE PLACED ABOVE TOP REINFORCING OF 9.
FINISHED ELEVATION.SEE CIVIL PLANS FOR ACTUAL FIRST FLOOR ELEVATION WITHIN PLANS.
REFERENCE ELEVATION 100.0FT IS THE ASSUMED FIRST FLOOR FINISHED 8.
UNDERGROUND UTILITIES.COORDINATED WITH ADJACENT DO NOT INSTALL FOUNDATIONS UNTIL FOUNDATION WORK HAS BEEN 7.
GREATER THAN DIMENSIONS INDICATED.FOOTING SCHEDULES. EXCAVATION WIDTHS SHALL BE A MINIMUM OF 4"
INDICATED ON THE FOUNDATION PLAN, SECTIONS, AND AND THICKNESSES ENSURE THAT EARTH-FORMED FOOTINGS CONFORM TO THE SHAPE, LINES, 6.
SUBGRADES.DO NOT PLACE FOUNDATION CONCRETE ON FROZEN OR SATURATED 5.
SLABS-ON-GRADE (TYPICAL).UNDER ALL PLACE 10 MIL VAPOR RETARDER AND 4" OF CAPILLARY WATER BARRIER 4.
REQUIREMENTS.REFER TO SPECIFICATION 31 00 00, EARTHWORK, FOR ADDITIONAL DURING EXCAVATIONS SHALL BE ACCOMPLISHED BY APPROVED MEANS. AND ANY PERCHED WATER CONDITIONS THAT MIGHT BE ENCOUNTERED PLACED AND BACKFILLED. REMOVAL OF SURFACE WATER, GROUNDWATER, SUBGRADE SOILS REMAINING DRY AND FIRM UNTIL AFTER FOOTINGS ARE ENSURE THAT ALL FOOTING EXCAVATIONS ARE ACCOMPLISHED WITH CONTRACTOR SHALL PROVIDE DRAINAGE AND DEWATERING AS REQUIRED TO OPERATIONS WILL BE CONTINUALLY AND EFFECTIVELY DRAINED. THE
THE SITE WHICH AFFECTS CONSTRUCTION IMMEDIATELY SURROUNDING ALL EXCAVATION SHALL BE PERFORMED SO THAT THE SITE AND AREA 3.
THEREAFTER.AS SOON AS PRACTICAL PLACE FOUNDATION CONCRETE THE SAME DAY EXCAVATIONS ARE MADE OR 2.
THE FACTOR OF SAFETY AGAINST UPLIFT SHOULD NOT BE LESS THAN 1.5.IS THE DEPTH OF FOOTING BASE MEASURED FROM FINISH GRADE ELEVATION. FOOTINGS IS 42 INCHES FOR FROST PENETRATION. MINIMUM FOOTING DEPTH
SPREAD FOOTINGS. MINIMUM DEPTH OF PERIMETER 3500 PSF FOR ISOLATED ALLOWABLE SOIL BEARING CAPACITY IS 3000 PSF FOR STRIP FOOTINGS AND 1.
DB
B-R
EA
DY T
O A
DV
ER
TIS
E
498 616
METAL BUILDING (PEMB) DESIGNER. MEMBERS SHALL NOT BE ALLOWED, UNLESS APPROVED BY THE PRE-ENGINEERED CLIP TO ATTACH TO STRUCTURAL MEMEBERS. DRILLING THROUGH STRUCTURAL ANY HANGERS SUPPORTING EQUIPMENT, DUCTWORK, PIPING, ETC. SHALL USE A 8.
DUCTS, FANS, PIPING, ELECTRICAL COMPONENTS, SUPPORTED PARTITIONS, ETC.DESIGN AND PROVIDE STRUCTURAL MEMBERS FOR THE SUPPORT OF HVAC UNITS, 7.
OTHER THAN METAL BUILDING WILL BE CONSTRUCTED AS SHOWN.LOADS PROVIDED BY METAL BUILDING MANUFACTURER. FOUNDATIONS FOR ITEMS REDESIGN METAL BUILDING FOUNDATIONS AND PIERS FOR ACTUAL BUILDING BE USED AS A GUIDE FOR THE BUILDING SUPPLIED. THE CONTRACTOR WILL FOUNDATIONS AND PIERS SHOWN ARE ESTIMATES FOR THE BUILDING AND ARE TO 6.
BY THE BUILDING.LIMITS SHALL NOT EXCEED DEFLECTION TOLERANCES OF EQUIPMENT SUPPORTED BUILDING COMPONENTS DO NOT CONTACT INTERIOR PARTITIONS. DEFLECTION LOW RISE BUILDINGS" 1990, DEFLECTIONS SHALL BE LIMITED TO ENSURE THAT STEEL DESIGN GUIDE SERIES 3 "SERVICEABILITY DESIGN CONSIDERATIONS FOR WITH "SERVICEABILITY CONSIDERATIONS" SUMMARY TABLES CONTAINED IN AISC BUILDING LATERAL DEFLECTIONS AND RACKING LIMITS SHALL BE IN ACCORDANCE 5.
ARE NOT ALLOWED.DESIGN BUILDING SYSTEM WITH HINGED COLUMN BASES. FIXED BASE COLUMNS 4.
LOAD COMBINATIONS ARE MORE STRINGENT.CODES UNLESS THE (MBMA) METAL BUILDING SYSTEMS MANUAL (LATEST EDITION) LOAD COMBINATIONS SHALL BE IN ACCORDANCE WITH APPLICABLE BUILDING 3.
CONCENTRATED LOADS EXCEED PURLIN CAPACITY.MECHANICAL EQUIPMENT LOADS SHOWN. USE SPREADER BEAMS WHERE LOCATED ANYWHERE ALONG THE LENGTH OF THE PURLIN IN ADDITION TO DESIGNED FOR AN ADDITIONAL CONCENTRATED LIVE LOAD OF 250 POUNDS AND LEEWARD WIND PRESSURE AND SUCTION LOADS. ROOF PURLINS SHALL BE LISTED IN THE DESIGN NOTES ON OMS S-001. INCLUDE THE EFFECTS OF WINDWARD LOADS. PARAMETERS FOR DEVELOPMENT OF WIND AND SEISMIC LOADS ARE LOAD OF 7 PSF IN ADDITION TO BUILDING DEAD LOADS, WIND LOADS AND SEISMIC DESIGN BUILDING SYSTEM FOR LIVE LOADS INDICATED AND A COLLATERAL DEAD 2.
DESIGN BUILDING SYSTEM(S) IN ACCORDANCE WITH THE BUILDING CODE.1.
W912
QR-1
3-R
0036
MA
RC
H 2
013
*** SAFETY PAYS ***
*** SUPPORT VALUE ENGINEERING - IT PAYS ***
DE
SIG
NE
D B
Y:
DR
AW
N B
Y:
CH
EC
KE
D B
Y:
PR
OJE
CT E
NGIN
EE
R/A
RC
HIT
EC
T
DA
TE
DR
AWIN
G C
OD
E:
SC
ALE:
DA
TE:
SY
MB
OL
RE
VISIO
NS
DE
SC
RIP
TIO
NA
PP
R.
DA
TE
OF ENGINEERS
US ARMY CORPS
CO
RP
S O
F E
NGIN
EE
RS
U.S.
AR
MY E
NGIN
EE
R DIS
TRIC
T
LOUISVILLE DISTRICT
SHEET REF NUMBER:
SHEET OF
1 2 3 4 5 6 7 98
F
E
D
A
B
C
05-MAR-2013
353449_OMS_S-003xxx.dgn
MA
RC
H 2
013
LO
UIS
VIL
LE DIS
TRIC
T
C.
GR
AS
S
PN
67659
F-1
71-4
0-1
76
FY13
A.
MC
CO
Y
E. F
RY
R. S
MIT
HS
HE
RID
AN A
RM
Y R
ES
ER
VE C
EN
TE
R (
AR
C)
SH
ERID
AN, IL
LIN
OIS
GENERAL NOTES
OMS
S-003
CO
MP.
& C
LA
DD.
OS
M B
UIL
DIN
G
0 4’ 8’ 16’
N
2
2
2
2
1
1
2
2
2
5
3
4
WIN
D U
PLIF
T DIA
GR
AM
1
2a
2a
2a
a
a
4a
a
aa
aa
a
2a
4a
2a
2a
3
4
54
33
33
a = 4.3’COMPONENTS AND CLADDING ROOF
ZONESAREA
TRIBUTARY
1 10 10.0 24.4
1 20 10.0 24.3
1 50 10.0 23.3
1 =100 10.0 22.3
2
2
2
2
3
3
3
3
4
4
4
4
5
5
5
5
10
20
50
=100
10
20
50
=100
10
20
50
=100
10
20
50
=100
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
40.9
36.7
30.8
26.4
61.6
51.1
37.0
26.4
32.6
32.0
30.9
30.7
50.8
45.3
38.0
32.6
a
(PSF)(+) PRESSURE
(PSF)(-) PRESSURE
P2 #
353449
499 616
DB
B-R
EA
DY T
O A
DV
ER
TIS
E
ZONESAREA
TRIBUTARY (PSF)
(+) PRESSURE(PSF)
(-) PRESSURE
38.8
(PSF)PRESSURE
(-) NET
AREATRIBUTARY ZONES
(PSF)PRESSURE
(+) NET
4 10
4
4
5
4
5
5
5
20
50
=100
10
20
50
=100
24.4
23.3
21.7
20.7
24.4
23.3
21.7
20.7
26.4
25.3
23.9
22.8
32.6
30.4
27.5
25.3
1 & 2
1 & 2
10 10
1 & 2
1 & 2
1 & 2
3
3
3
3
3
20
50
100
500
10
20
50
100
500
10
10
10
10
10
10
10
10
10
38.2
37.4
36.8
26.4
61.6
49.1
32.7
20.2
20.2
a = 4.3’COMPONENTS AND CLADDING WALL
a = 4.3’COMPONENTS AND CLADDING ROOF OVERHANG
WIND LOADING DIAGRAM - MINIMUM COMPONENTS & CLADDING PRESSURES1/8" = 1’-0"
A1
SHOWN ON THIS SHEET.
DEAD LOAD IS NOT CONSIDERED IN THE PRESSURES5.
OVERHANG ROOF AREAS.
BUT THEY SHOULD BE APPLIED TO ALL PERTINENT
BEEN OMMITED FROM DIAGRAM FOR CLARIFICATION,
OVERHANG PRESSURE COEFFICIENT AREAS HAVE4.
MINIMUM DESIGN VALUES.
SPECIFIED ON THIS DRAWING ARE TO BE USED AS
LOADS IN ACCCORDANCE WITH ASCE 7-05. LOADS
PEMB MANUFACTURER SHALL DETERMINE WIND UPLIFT3.
SEE PLANS FOR DIMENSIONS2.
STRUCTURAL NOTES.
SEE SHEETS S-001 AND S-002 FOR GENERAL1.
W912
QR-1
3-R
0036
MA
RC
H 2
013
*** SAFETY PAYS ***
*** SUPPORT VALUE ENGINEERING - IT PAYS ***
DE
SIG
NE
D B
Y:
DR
AW
N B
Y:
CH
EC
KE
D B
Y:
PR
OJE
CT E
NGIN
EE
R/A
RC
HIT
EC
T
DA
TE
DR
AWIN
G C
OD
E:
SC
ALE:
DA
TE:
SY
MB
OL
RE
VISIO
NS
DE
SC
RIP
TIO
NA
PP
R.
DA
TE
OF ENGINEERS
US ARMY CORPS
CO
RP
S O
F E
NGIN
EE
RS
U.S.
AR
MY E
NGIN
EE
R DIS
TRIC
T
LOUISVILLE DISTRICT
SHEET REF NUMBER:
SHEET OF
1 2 3 4 5 6 7 98
F
E
D
A
B
C
05-MAR-2013
353449_OMS_S-101xxx.dgn
MA
RC
H 2
013
A
1
C D FB E
2
3
A C D FB E
LO
UIS
VIL
LE DIS
TRIC
T
C.
GR
AS
S
PN
67659
F-1
71-4
0-1
76
FY13
A.
MC
CO
Y
E. F
RY
R. S
MIT
HS
HE
RID
AN A
RM
Y R
ES
ER
VE C
EN
TE
R (
AR
C)
SH
ERID
AN, IL
LIN
OIS
GENERAL NOTES
OMS
S-101
FO
UN
DA
TIO
N P
LA
N
OS
M B
UIL
DIN
G
A1
S-302
E1
S-302
E1
S-301
C1
S-302
A4
S-501
C7
S-301
FOUNDATION PLAN1/8" = 1’-0"
A10 4’ 8’ 16’
N
8" S
LA
B6" S
LA
B
WW
R 6
x6 - W
2.9
xW
2.9
CJ
CJ
CJ
CJ
CJ
CJ
CJ CJ
CJ
CJ
CJ
CJ
CJ
1
2
3
1 1 2
2 3
BRICK VENEER
SHEET KEYNOTES
FOUNDATION NOTES
LEGEND
@ DOOR WAY
POUR THROUGH
4
2
4
4
8" S
LA
B6" S
LA
B
WW
R 6
x6 - W
2.9
xW
2.9
WW
R 4
x4 - W
2.9
xW
2.9
2 L
AY
ER
S O
F
W2
W2
W2
W2
A4
S-501
WW
R 4
x4 W
2.9
xW
2.9
2 L
AY
ER
S O
F
D4
S-301
"8519’-101’-4"
24’-0"
24’-0"
24’-0"
1’-4""8519’-1031’-8"
GRADE.
FOOTINGS SHALL BE 42" BELOW FINAL EXTERIOR
THE MINIMUM DEPTH TO THE BOTTOM OF EXTERIOR7.
FOUNDATIONS, UNO.
BRACING REQUIRED. DO NOT UNDERCUT EXISTING
CONTRACTOR IS RESPONSIBLE FOR ANY SHORING OR
PROTECT EXISTING FOUNDATION SYSTEMS. THE 6.
UNDERGROUND UTILITIES.
WORK HAS BEEN COORDINATED WITH ADJACENT
DO NOT INSTALL FOUNDATIONS UNTIL FOUNDATION 5.
FROZEN OR SATURATED SUBGRADES.
BOTTOMS. DO NOT PLACE FOUNDATION CONCRETE ON
ACCUMULATING AND STANDING IN THE EXCAVATION
FOUNDATION EXCAVATIONS TO PREVENT WATER FROM
PRACTICAL THEREAFTER. ADEUATLEY PROTECT
EXCAVATIONS ARE MADE OR AS SOON AS
PLACE FOUNDATION CONCRETE THE SAME DAY 4.
SHALL BE SUBMITTED TO THE ENGINEER.
RECOMMENDATIONS. INSPECTING & TESTING REPORTS
CONSTRUCTION PER GEOTECHNICAL REPORT
DURING GRADING & FOUNDATION PHASE OF
PROVIDE OBSERVATION & TESTING SERVICES
GEOTECHNICAL ENGINEER SHALL BE RETAINED TO 3.
CAPACITY OF 3500 PSF. SEE GENERAL NOTE 8.
CONTRACTOR FOR ALLOWABLE SOIL BEARING
ISOLATED SPREAD FOOTINGS SHALL BE DESIGNED BY 2.
ALLOWABLE SOIL BEARING CAPACITY OF 3000 PSF.
STRIP FOOTINGS HAVE BEEN DESIGNED FOR 1.
FOOTING SCHEDULE
TYPE LENGTH WIDTH THICKNESS REINFORCING
4’-0" 1’-0"
10’-0" 10’-0" (10) #7 EW, T&B1’-4"
FC3 3’-0" 1’-4"(4) #5 LONGITUDINAL
AND #6 @ 16" O.C.
F4 4’-0" (5) #5 EW, T&B
F10
REINFORCING BARS
REMARKS
TIESVERTICAL
MARK
P-1 2’-4" x 3’-0" #4@128) #7
97’-4"
T/FTG EL., UNO
CONT.
SIZE
PIER SCHEDULE
F10 F10 F10 F10
F10
F10
F10F10F10F10
F10
F10
F10 F10
FC3 FC3 FC3
FC3 FC3 FC3
FC
3
FC
3
FC
3
FC
3
97’-4"
97’-4"
CJCJ
A1
S-301
C7C7
S-301
F4 F4
SEE FOUNDATION NOTES AND GENERAL NOTES.THE BUILDING AND ARE TO BE USED AS A GUIDE FOR THE BUILDING SUPPLIED.THE SPREAD FOOTINGS SHOWN ON THIS SHEET ARE ESTIMATES FORTHE CONTINUOUS STRIP FOOTINGS HAVE BEEN DESIGNED.NOTE:
10’-0" "854’- 10’-1" "8
31’-8 "858’-114’-7"6’-0"
"836’-1 9"
"4
12’-7
7’-4"
8’-8"
5’-4"
4’-7"
11’-0"
5’-4"
"8
57’-9
"8
38’-6
"8
57’-7
TYP.
CONCRETE STEM WALL BENEATH CMU WALL
CAST-IN PLACE CONCRETE REPRESENTING
S-301
P2 #
353449
WALL
WITHOUT
SIM.
5 5
5
CMU ON 6" REINFORCED CONCRETE SLAB
CJ
CJ
THE SLAB FOR ADDITIONAL CRACK CONTROL, TYP.
PLACE (2) #4 BARS x 4’-0" LONG IN THE TOP ONE THIRD OF6.
4" CMU COLUMN WRAP, SEE ARCHITECTURAL.5.
SEE OMS C7/S-301 FOR CONCRETE SLAB THROUGH DOOR.4.
NO X-BRACING OR PORTAL FRAME ALLOWED3.
X-BRACING OR PORTAL FRAME ALLOWED2.
PORTAL FRAME ALLOWED1.
6
TYP.6
TYP.
11’-8"11’-8"
"4197’-5
"4
173’-5
"4
141’-5
32’-0"CJ
CJ
500 616
SEE OMS S-601 FOR WALL SCHEDULE.
WALLS NOT LABELED ARE 8" CMU WALLS.10.
SEE OMS A1/S-302 & E1/S-302 FOR DRAIN LOCATIONS.9.
MANUFACTURER.
LOADS AND DIMENSIONS PROVIDED BY THE PEMB
FOUNDATIONS FOR THE ACTUAL BUILDING
THE CONTRACTOR WILL REDESIGN THE
USED AS A GUIDE FOR THE BUILDING SUPPLIED.
ESTIMATES FOR THE BUILDING AND ARE TO BE
THE FOUNDATIONS SHOWN ON THIS SHEET ARE8.
GIRTS, UNO.
DIMENSIONS TO CMU WALLS ARE TO OUTSIDE FACE OF
GRID LINES AT EXTERIOR FACE OF GIRTS AND ALL 7.
AND ENCASE SLEEVE IN CONCRETE. SEE OMS S-502.
THAT UTILITIES GO UNDER FOOTINGS, DEEPEN FOOTING
FOUNDATION WALL AS REQUIRED. IF ELEVATIONS DEMAND
CONTRACTOR SHALL PROVIDE UTILITY SLEEVES THROUGH 5.
SPACING OF CONSTRUCTION JOINTS IS 100 FT.
AFTER THE POUR IS UNACCEPTABLE. THE MAXIMUM
HOURS OF INITIAL SET. SAW-CUTTING THE MORNING
ENSURE THAT ALL SAW CUTS ARE COMPLETED WITHIN 12
MAXIMUM SQUARE FOOTAGE THAT CAN BE PLACED AND
JOINTS ARE TO BE CONSTRUCTION JOINTS BASED ON THE
THE CONCTRACTOR SHALL DETERMINE WHICH OF THESE
CJ REFERS TO CONTROL AND/OR CONSTRUCTION JOINT. 4.
100’-0" IS EQUIVALENT TO ELEVATION 677.75’.
THE ASSUMED FINISHED FLOOR REFERENCE ELEVATION 3.
SEE ARCH. PLANS FOR DIMENSIONS NOT SHOWN.2.
STRUCTURAL NOTES.
SEE SHEETS OMS S-001 AND OMS S-002 FOR GENERAL 1.
ADDITIONAL #4 TIE AT TOP
DB
B-R
EA
DY T
O A
DV
ER
TIS
E
CJ
"8
512’-
"8
55’-4
11’-8" 3’-10" 3’-10" "8521’-2 11’-8""8
521’-2
CJ
CJ
MA
RC
H 2
013
W912
QR-1
3-R
0036
*** SAFETY PAYS ***
*** SUPPORT VALUE ENGINEERING - IT PAYS ***
DE
SIG
NE
D B
Y:
DR
AW
N B
Y:
CH
EC
KE
D B
Y:
PR
OJE
CT E
NGIN
EE
R/A
RC
HIT
EC
T
DA
TE
DR
AWIN
G C
OD
E:
SC
ALE:
DA
TE:
SY
MB
OL
RE
VISIO
NS
DE
SC
RIP
TIO
NA
PP
R.
DA
TE
OF ENGINEERS
US ARMY CORPS
CO
RP
S O
F E
NGIN
EE
RS
U.S.
AR
MY E
NGIN
EE
R DIS
TRIC
T
LOUISVILLE DISTRICT
SHEET REF NUMBER:
SHEET OF
1 2 3 4 5 6 7 98
F
E
D
A
B
C
05-MAR-2013
353449_OMS_S-301xxx.dgn
MA
RC
H 2
013
LO
UIS
VIL
LE DIS
TRIC
T
C.
GR
AS
S
PN
67659
F-1
71-4
0-1
76
FY13
A.
MC
CO
Y
E. F
RY
R. S
MIT
HS
HE
RID
AN A
RM
Y R
ES
ER
VE C
EN
TE
R (
AR
C)
SH
ERID
AN, IL
LIN
OIS
OMS
S-301
ST
RU
CT
UR
AL S
EC
TIO
NS
OM
S B
UIL
DIN
G
(4) #5 - CONT
SEE PLAN
REINFORCEMENT,
8" CMU
PER ARCH.
SPRAY FOAM INSULATION
C7
S-501
CMU WALL
ARCH.BRICK PER
ANGLE
(3) #5 - CONT
ARCH.
BRICK PER
(4) - #5 EQ. SPACED
#6 @ 16" O.C.
SIZE & SPACING
TO MATCH WALL REINF
DOWELS W/STD 90° HOOK
(3) #5 - CONT
(4) - #5 EQ. SPACED
#6 @ 16" O.C.
SIZE & SPACING
TO MATCH WALL REINF
DOWELS W/STD 90° HOOK
(3) #5 - CONT
SEE PLAN
REINFORCEMENT,
DRAIN & REINF.A1/S-501 FORSEE TYP. DETAILTRENCH DRAIN,
CHANNEL PER PEMB
GIRT PER PEMB
SECTION3/4" = 1’-0"
E1
SECTION3/4" = 1’-0"
C7
0 1’ 2’ 3’
0 1’ 2’ 3’
SECTION3/4" = 1’-0"
A7
MANUFACTURERPURLIN PER PEMB
MANUFACTURERCHANNEL PER PEMB
PER PEMBCHANNEL
PER PEMBPURLIN
GIRT PER PEMB
PEMB MANUFACTURERLEAN-TO FRAME PER
2’-2"
MIN.
1’-4"
1’-3"
[SEE PLAN]
1’-3"
HOOK HEIGHT OF 20 FEETPER MANUFACTURER WITH10 TON, OVERHEAD CRANE
1" GAP BETWEEN ANGLE & CMU WALL
TO 9" @ EDGETHICKEN SLAB
2
1
PAVEMENT, SEE CIVIL
MAT.EXP.
SEE CIVILPAVEMENT,
1’-4"
2’-2"
MIN.
T.O. MASONRY
SECTION3/16" = 1’-0"
A10 2’ 4’ 8’
2" MIN. GAP BETWEEN FRAME & CMU WALL
MANUFACTURERPER PEMB
FRAME
108’-8"
MANUFACTURERPER PEMB FRAME
A7
S-301
PURLIN ABOVE, PER PEMB MANUFACTURER
CHANNEL ABOVE, PER PEMB MANUFACTURER
MANUFACTURERPER PEMBGIRT ABOVE,
PURLIN PER PEMB MANUFACTURER
MANUFACTURERPER PEMBCHANNEL
MANUFACTURERPER PEMBCHANNEL
MANUFACTURERGIRT PER PEMB
3’-0"
3’-0"
FOUNDATION DESIGNER, TYP.PER CONTRACTOR’S REINFORCINGFOUNDATION AND
MANUFACTURERFRAME PER PEMB
SECTION3/16" = 1’-0"
D4
4’ 8’0 12’
4’ 8’0 12’
SEE TYP. DETAILSPOROUS FILL,
SEE TYP. DETAILSVAPOR BARRIER,
SEE TYP. DETAILSRIGID INSULATION,
SEE TYP. DETAILSPOROUS FILL,
SEE TYP. DETAILSVAPOR BARRIER,
SEE TYP. DETAILSRIGID INSULATION,
TYP.
5’-2"
501
P2 #
353449
616
DB
B-R
EA
DY T
O A
DV
ER
TIS
E
1/2" EJ, TYP.
1/2" EJ, TYP.
"836
FINISHED FLOOR
W912
QR-1
3-R
0036
MA
RC
H 2
013
*** SAFETY PAYS ***
*** SUPPORT VALUE ENGINEERING - IT PAYS ***
DE
SIG
NE
D B
Y:
DR
AW
N B
Y:
CH
EC
KE
D B
Y:
PR
OJE
CT E
NGIN
EE
R/A
RC
HIT
EC
T
DA
TE
DR
AWIN
G C
OD
E:
SC
ALE:
DA
TE:
SY
MB
OL
RE
VISIO
NS
DE
SC
RIP
TIO
NA
PP
R.
DA
TE
OF ENGINEERS
US ARMY CORPS
CO
RP
S O
F E
NGIN
EE
RS
U.S.
AR
MY E
NGIN
EE
R DIS
TRIC
T
LOUISVILLE DISTRICT
SHEET REF NUMBER:
SHEET OF
1 2 3 4 5 6 7 98
F
E
D
A
B
C
05-MAR-2013
353449_OMS_S-302xxx.dgn
MA
RC
H 2
013
LO
UIS
VIL
LE DIS
TRIC
T
C.
GR
AS
S
PN
67659
F-1
71-4
0-1
76
FY13
A.
MC
CO
Y
E. F
RY
R. S
MIT
HS
HE
RID
AN A
RM
Y R
ES
ER
VE C
EN
TE
R (
AR
C)
SH
ERID
AN, IL
LIN
OIS
OMS
S-302
ST
RU
CT
UR
AL S
EC
TIO
NS
OM
S B
UIL
DIN
G
SECTION3/4" = 1’-0"
C1
SECTION3/4" = 1’-0"
A1
0 1’ 2’ 3’
0 1’ 2’ 3’
8" CMU
WATERSTOP, CONT, TYP.
(4) #5 CONT
W/STD 90° HOOK
#5 x 2’-0" @ 12" OC
#6 @ 16" OC
(4) #5 CONT.
REINFORCEMENT, SEE PLAN
SADDLE CLIPSGRATING W/2" ALUMINUM
GALVANIZED, TYP.AT 18" OC,STUDSLONG HEADEDw/ 1/2"Ø x 4"GALVANIZEDCONT L2x2x1/4,
8"
TYPICAL, ALL SIDES ALUM. AND CONCRETE, OR COATING BETWEEN1/4" GALV. STEEL PLATE
WALL BEYOND
GALVANIZED, TYP. LONG HEADED STUDS AT 18" OC,
CONT L2x2x1/4, GALVANIZED w/ 1/2"Ø x 4"
(4) #5
#6 @ 16" OC
2"
[98’-8"]
#6 @ 16" O.C.
(4) #5 CONT
(6) #5 CONT
W/STD 90° HOOK
#5 x 2’-0" @ 12" OC
EL 100’-0"
FINISHED FLOOR
8" CMU WALL
GALV, TYP
STUDS @ 18" OC,
LONG HEADED
GALV W/ 1/2"Øx6"
CONT L4x4x1/4,
(4) #5
#6 @ 16" 0.C.
SIZE AND SPACE
HOOK TO MATCH WALL REINF
DOWELS W/STANDARD 90°
(4) #5 CONT
SIZE AND SPACE
HOOK TO MATCH WALL REINF
DOWELS W/STANDARD 90°
#6 @ 16" O.C.
(6) #5 CONT
EL 100’-0"
FINISHED FLOOR
8" CMU WALL 8" CMU WALL
WATERSTOP CONT, TYP
4"4"
W/STD 90° HOOK
#5 x 2’-0" @ 12" OC
W/STD 90° HOOK
#5 x 2’-0" @ 12" OC
CONT, TYP
WATERSTOP,
W/STD 90° HOOK
#5 x 2’-0" @ 12" OC
(8) #5 CONT
EL 100’-0"
FINISHED FLOOR
SLAB PER PLAN
[98’-8"]
[98’-8"]
SADDLE CLIPSGRATING W/2" ALUMINUM
SADDLE CLIPSGRATING W/2" ALUMINUM
W8x13W8x13
SADDLE CLIPSGRATING W/2" ALUMINUM
W8x13 W8x13
EL 100’-0"
FINISHED FLOOR
8" CMU WALL
(4) #5 CONT
WATERSTOP CONT, TYP
#6 @ 16" O.C.
(4) #5 CONT
SIZE AND SPACE
HOOK TO MATCH WALL REINF
DOWELS W/STANDARD 90°
GALV, TYP
STUDS @ 18" OC,
LONG HEADED
GALV W/ 1/2"Øx4"
CONT L2x2x1/4,
W/STD 90° HOOK
#5 x 2’-0" @ 12" OC
(4) #5 CONT
#6 @ 16" O.C.
SIZE AND SPACE
HOOK TO MATCH WALL REINF
DOWELS W/STANDARD 90°
(7) #5 CONT
8" CMU WALL
SLAB PER PLAN
SLAB PER PLAN
SLAB PER PLAN
EQ. SP. EQ. SP. EQ. SP.
4"
P2 #
353449
ADD WATERSTOP
DCJ, SIMILAR TO C1/S-501,
110 AND 111
THROUGH CJ IN ROOMS
WATERSTOP CONTINUOUS
0 1’ 2’ 3’
SECTION3/4" = 1’-0"
E1
502 616
DB
B-R
EA
DY T
O A
DV
ER
TIS
E
3’-0" 3’-0" 3’-0"
SIZE AND SPACE
WALL REINF
90° HOOK TO MATCH
DOWELS W/STANDARD
3’-0" 3’-0"
3’-0" 3’-0"
1’-4"
1’-4"
2’-2"
MIN
1’-4"
2’-2"
MIN.
2’-2"
MIN.
TYP. REINF SIZE AND SPACING,
HOOK TO MATCH WALLDOWELS W/ STANDARD 90°
SIZE AND SPACING, TYP
HOOK TO MATCH WALL REINF
DOWELS W/STANDARD 90°
OMS S-501.
SEE DETAILS ON
SLAB PER PLAN.
EJ, TYP.
OMS S-501.
SEE DETAILS ON
SLAB PER PLAN.
OMS S-501.
SEE DETAILS ON
SLAB PER PLAN.
BELOW GRADEGROUT SOLID
1/2" EJ, TYP.
1/2" EJ, TYP.
SEE CIVIL DRAWINGSPAVING OR FINISHED GRADE,
SEE CIVIL DRAWINGS
1/2" EJ, TYP.
4"
2"
W912
QR-1
3-R
0036
MA
RC
H 2
013
*** SAFETY PAYS ***
*** SUPPORT VALUE ENGINEERING - IT PAYS ***
DE
SIG
NE
D B
Y:
DR
AW
N B
Y:
CH
EC
KE
D B
Y:
PR
OJE
CT E
NGIN
EE
R/A
RC
HIT
EC
T
DA
TE
DR
AWIN
G C
OD
E:
SC
ALE:
DA
TE:
SY
MB
OL
RE
VISIO
NS
DE
SC
RIP
TIO
NA
PP
R.
DA
TE
OF ENGINEERS
US ARMY CORPS
CO
RP
S O
F E
NGIN
EE
RS
U.S.
AR
MY E
NGIN
EE
R DIS
TRIC
T
LOUISVILLE DISTRICT
SHEET REF NUMBER:
SHEET OF
1 2 3 4 5 6 7 98
F
E
D
A
B
C
05-MAR-2013
353449_OMS_S-501xxx.dgn
MA
RC
H 2
013
LO
UIS
VIL
LE DIS
TRIC
T
C.
GR
AS
S
PN
67659
F-1
71-4
0-1
76
FY13
A.
MC
CO
Y
E. F
RY
R. S
MIT
HS
HE
RID
AN A
RM
Y R
ES
ER
VE C
EN
TE
R (
AR
C)
SH
ERID
AN, IL
LIN
OIS
OMS
S-501
OM
S B
UIL
DIN
G
CONCRETE SLAB-ON-GRADE
REINFORCEMENT, SEE PLAN
SLAB-ON-GRADECONCRETE
SEE PLANREINFORCEMENT,
1/8" RADIUS TOOLED EDGE (TYP)
CONCRETE SLAB-ON-GRADE
T
#5 AT 24" OC
2’-6"
CONT PL 1/4" (GALVANIZED)
2 - #5 CONT
FABRIC AT 3’-0" OC EACH WAYSUPPORT FOR WELDED WIRE
SLAB THICKNESSSAWCUT JOINT, DEPTH EQUAL TO 1/4 OF
BONDPREVIOUS POUR TO PREVENT ALONG ENTIRE FACE OF APPLY CURING COMPOUND
BOND AT 12" OC COATED TO PREVENT
3/4" Ø x 16" LONG SMOOTH DOWEL
RADON BARRIER10 MIL VAPOR/
RADON BARRIER10 MIL VAPOR/
RADON BARRIER10 MIL VAPOR/
RADON BARRIER10 MIL VAPOR/
–8"
T/2
T/2
TYPICAL SLAB-ON-GRADE (SOG)NOT TO SCALE
E1
TYPICAL SLAB-ON-GRADE SAWED (CONTRACTION) JOINT (SJ)NOT TO SCALE
E4TYPICAL SLAB DEPRESSION (SD)NOT TO SCALE
C7TYPICAL DOWELED CONSTRUCTION JOINT (DCJ)NOT TO SCALE
C1
TYPICAL TRENCH DRAINNOT TO SCALE
A1TYPICAL THICKENED SLAB AT TRANSITIONNOT TO SCALE
A4
SE
E P
LA
N
SLOPE
SEE CIVILPAVEMENT,
INSIDE FACE OF DOORFACE OF BRICK
TY
PIC
AL D
ET
AIL
S
TRENCH(2) - #5 CONT UNDER
3" CLR TYP
REINFORCEMENT.SUPPORT DOWELS INDEPENDENTLY OF 2.
PARALLEL TO TOP OF SLAB.POSITION DOWELS PERPENDICULAR TO JOINT AND 1.
NOTES:
TOC
1
1
1"@12"
1"@12"
"4
31
"4
1
7"
ONLY UNDER 8" SLAB2" RIGID INSULATION
ONLY UNDER 8" SLAB2" RIGID INSULATION
ONLY UNDER 8" SLAB2" RIGID INSULATION
1"
TO PREVENT BONDINGFACE OF PREVIOUS POUR COMPOUND TO ENTIRE APPLY LIQUID CURING
8" SLAB-ON-GRADE
SEE PLANREINFORCEMENT,
6" SLAB-ON-GRADE
ONLY UNDER 8" SLAB2" RIGID INSULATION
SPACING REINFORCING SIZE AND
DOWELS TO MATCH WALL
TO PREVENT BONDDOWEL @ 12" OC COATED 3/4"Ø x 24" LONG SMOOTH
(2) - #5 CONT
NEW POUR PREVIOUS POUR
48 X B
AR DIA
M.
1’-2"
2" 2"
SE
E P
LA
N
6" CA-7 STONE
2" CA-6 STONE
2" CA-6 STONE6" CA-7 STONE
2" CA-6 STONE
6" CA-7 STONE
8"3’-0"8"
1’-0"1’-0"
6" CA-7 STONE
2" CA-6 STONE
LONG HEADED STUDS AT 18" OC (GALV)L2x2x1/4 WITH 1/2" Ø x 4"
1’-4"
8"
2" CA-6 STONE
6" CA-7 STONE
ONLY UNDER 8" SLAB2" RIGID INSULATION
ONLY UNDER 8" SLAB2" RIGID INSULATION
P2 #
353449
BAR GRATING1 1/2" x 1/4" NON-SPARK
503 616
8"
PL
AN
SE
E
DB
B-R
EA
DY T
O A
DV
ER
TIS
E
O.C. VERTICAL REINFORCEMENTCMU WALL PER PLAN WITH #5 @ 32"
TYP.1/2" EJ,
BOND AT 12" OC COATED TO PREVENT
3/4" Ø x 16" LONG SMOOTH DOWEL
LONG HEADED STUDS AT 18" OC (GALV)L4x4x1/4 WITH 1/2" Ø x 6"
FINISHED FLOOR
FINISHED FLOOR FINISHED FLOOR
FINISHED FLOOR
MA
RC
H 2
013
W912
QR-1
3-R
0036
*** SAFETY PAYS ***
*** SUPPORT VALUE ENGINEERING - IT PAYS ***
DE
SIG
NE
D B
Y:
DR
AW
N B
Y:
CH
EC
KE
D B
Y:
PR
OJE
CT E
NGIN
EE
R/A
RC
HIT
EC
T
DA
TE
DR
AWIN
G C
OD
E:
SC
ALE:
DA
TE:
SY
MB
OL
RE
VISIO
NS
DE
SC
RIP
TIO
NA
PP
R.
DA
TE
OF ENGINEERS
US ARMY CORPS
CO
RP
S O
F E
NGIN
EE
RS
U.S.
AR
MY E
NGIN
EE
R DIS
TRIC
T
LOUISVILLE DISTRICT
SHEET REF NUMBER:
SHEET OF
1 2 3 4 5 6 7 98
F
E
D
A
B
C
05-MAR-2013
353449_OMS_S-502xxx.dgn
MA
RC
H 2
013
LO
UIS
VIL
LE DIS
TRIC
T
C.
GR
AS
S
PN
67659
F-1
71-4
0-1
76
FY13
A.
MC
CO
Y
E. F
RY
R. S
MIT
HS
HE
RID
AN A
RM
Y R
ES
ER
VE C
EN
TE
R (
AR
C)
SH
ERID
AN, IL
LIN
OIS
OMS
S-502
OM
S B
UIL
DIN
G
TY
PIC
AL D
ET
AIL
S
TYPICAL UTILITY PIPE UNDER FOOTINGNOT TO SCALE
A1TYPICAL PIPE SLEEVENOT TO SCALE
A6
PIPE SLEEVE NOTES
TYPICAL UTILITY PIPE THRU FOOTINGNOT TO SCALE
D1
1
1
T
1’-0"
EACH SIDE
MINIMUM
FOOTING
2" LARGER THAN PIPE DIA.PROVIDE PIPE SLEEVE WITH DIA.
UTILITY LINEPLUMBING/
FOOTING
MIX CONCRETE - 2500 PSIOF FOOTING USING LEANCONCRETE TO BOTTOMFILL PIPE TRENCH WITH
COVER3" MIN.
UTILITY LINEPLUMBING/
LARGER PIPE SLEEVES OR OPENINGS
FLOOR SLAB REINFORCING AT 8" ORFUTURE PIPE SLEEVE
ANCHORS TO PIPE SLEEVEREINFORCING BARS FORWELD 4 (4" MIN.) SCRAP
MIN.
1’-0"
MIN.
1’-0"
2"
8" DIA. AND UNDER 24" DIA.
(2) #4 EACH WAY IF SLEEVE OVER
2" LARGER THAN PIPE DIA.PROVIDE PIPE SLEEVE WITH DIA.
#5@12" O.C. (6) #5
ELE
VA
TIO
N
BE
LO
W PIP
E
FT
G D
OW
N
ST
EP W
ALL
TT
SE
E P
LA
N
WALL
WALL
STEM WALL
STEM WALL
PIPE DIA.LARGER THAN
SLEEVE W/DIA. 2"PROVIDE PIPE
DWGS FOR CONDUIT OPENINGS BEFORE CONCRETE PLACEMENT.AGAINST PLUMBING DWGS FOR SLEEVES AND ELECTRICAL AND SMALLER UNLESS SHOWN OTHERWISE. CHECK FLOORSCONTRACTOR TO LOCATE IN FIELD PIPE SLEEVES FOR PIPE 3" 3.
OPENINGS LESS THAN 8".EQUALLY TO EACH SIDE OF OPENING. DO NOT CUT STEEL FORAT ALL SMALL OPENINGS (<8" DIA.) SPREAD REINFORCING 2.
DETAILED ON DESIGN DRAWINGS.)AND BOTTOM. MORE REINFORCING SHALL BE PROVIDED IF (MIN. OF #4 BARS AT 45 DEGREES TO MAIN REINFORCEMENT TOP TO BE DIAMETER OF OPENING PLUS 60 BAR DIAMETERS. TO REPLACE AREA OF BARS CUT BY OPENING. BAR LENGTHS ADD ADDITIONAL BARS TOP & BOTTOM AT EACH SIDE OF SLEEVES 1.
MA
RC
H 2
013
DB
B-R
EA
DY T
O A
DV
ER
TIS
E
504
P2 #
353449
W912
QR-1
3-R
0036
616
*** SAFETY PAYS ***
*** SUPPORT VALUE ENGINEERING - IT PAYS ***
DE
SIG
NE
D B
Y:
DR
AW
N B
Y:
CH
EC
KE
D B
Y:
PR
OJE
CT E
NGIN
EE
R/A
RC
HIT
EC
T
DA
TE
DR
AWIN
G C
OD
E:
SC
ALE:
DA
TE:
SY
MB
OL
RE
VISIO
NS
DE
SC
RIP
TIO
NA
PP
R.
DA
TE
OF ENGINEERS
US ARMY CORPS
CO
RP
S O
F E
NGIN
EE
RS
U.S.
AR
MY E
NGIN
EE
R DIS
TRIC
T
LOUISVILLE DISTRICT
SHEET REF NUMBER:
SHEET OF
1 2 3 4 5 6 7 98
F
E
D
A
B
C
07-MAR-2013
353449_OMS_S-601xxx.dgn
MA
RC
H 2
013
LO
UIS
VIL
LE DIS
TRIC
T
C.
GR
AS
S
PN
67659
F-1
71-4
0-1
76
FY13
A.
MC
CO
Y
E. F
RY
R. S
MIT
HS
HE
RID
AN A
RM
Y R
ES
ER
VE C
EN
TE
R (
AR
C)
SH
ERID
AN, IL
LIN
OIS
OMS
S-601
OM
S B
UIL
DIN
G
EQ
EQ
EQ
EQ
EQ
EQ
EQEQ
EQ
EQ
EQEQ
DIAMETERSLAP 48 BARREINFORCING,JAMB VERTICAL
SEE PLAN
BRG8"
EQEQVERTICAL WALL REINFORCING
TO ARCHITECTURAL DWGSCONTROL JOINT - REFER
(TYP)VERTICAL WALL REINFORCING
CORNER CONTROL JOINT
INTERSECTION
(TYP)VERTICAL WALL REINFORCING
OPENING - WALL TERMINATION
WALL REINFORCINGADDITIONAL VERTICAL
16" WIDEGROUT SOLID 30" DEEP x
OPENING
NOT AT CONTROL JOINT
JOINTCONTROLMASONRY
AT CONTROL JOINT
SEE "NOT AT CONTROL JOINT"FOR ADDITIONAL INFORMATIONNOTE:
NOT SHOWN FOR CLARITY.VENEER MASONRY AND SHELF ANGLES NOTE:
SECTION
LINTEL SCHEDULE THIS SHEETBOTTOM REINFORCING, SEE
BOTTOM OF LINTEL
REINFORCINGTYPICAL VERTICAL WALL
[SEE ARCH]
TYPICAL
REMARKS
VERTICAL
REINFORCEMENT
HORIZONTAL
8" CMU
THICKNESSMATERIAL AND
MARK
W1
CLEAR SPAN
0’-0" TO 3’-4"
3’-5" TO 5’-4"
5’-5" TO 8’-0"
"D"DEPTH
8"
8"
16"
"W"WIDTH
8"
8"
8"
REINFORCING
2-#5 BOTTOM
2-#5 BOTTOM
2-#5 TOP AND BOTTOM
8"
DE
TAIL
S
TY
PIC
AL M
AS
ON
RY
TYPICAL 6" CMUW2
REINFORCING (TYP)VERTICAL WALL
MASONRY LAP SPLICE
f.y =
f.t =
f.m =
BAR
IN
IN
IN
IN
IN
#3
#4
#5
#6
#7
60000
24000
18
24
30
36
42
48
PSI
PSI
PSI
IN#8
ld
#3
#4
#5
#6
#7
#8
#9
REINFORCED CONCRETE
OTHER THAN TOPCLASS B SPLICES FOR REINFORCEMENT,
BAR SIZE 4000 PSI
18"
25"
31"
37"
54"
62"
70"
#3
#4
#5
#6
#7
#8
#9
BAR SIZE 4000 PSI
24"
32"
48"
70"
80"
90"
AS TOP BARSCLASS B SPLICES FOR REINFORCEMENT
40"
EMBEDMENT SHALL BE IAW ACI 318-05
(2) #5 @ 48"OC MAX
(1) #5 @ 48"OC MAX
(1) #5 AT 32" OC
(1) #5 AT 32" OC
CMU LINTEL SCHEDULE
REINFORCINGTHIS SHEET FOR SIZE AND SEE CMU LINTEL SCHEDULE
2’-0"
1500
TYPICAL MASONRY VERTICAL WALL REINFORCEMENTN.T.S.
E1WALL SCHEDULEN.T.S.
E5
TYPICAL CMU LINTELN.T.S.
C1
P2 #
353449
OF ROUGH OPENING OF WINDOWADDITIONAL (2) #5 BAR, EXTEND 2’-0" BEYOND EACH SIDESILL REINFORCEMENT @ WINDOW NOT SHOWN -5.
NOT OTHERWISE SHOWN ON THE DRAWINGS.CMU LINTEL SCHEDULE APPLIES ONLY TO LINTELS4.
WIDTH OF WALL.AND REQUIRED WIDTH OF LINTEL, IF DIFFERENT FROMSEE ARCHITECTURAL DRAWINGS FOR WIDTH OF WALL3.
PLUMBING, AND ELECTRICAL DRAWINGS.COORDINATE WITH ARCHITECTURAL, MECHANICAL,FOR EXACT SIZE AND LOCATION OF ALL WALL OPENINGS2.
PROVIDE 8" CMU BEARING EACH END OF LINTEL.1.
NOTES:
LAP SPLICE TABLE fy = 60ksi
505 616
DB
B-R
EA
DY T
O A
DV
ER
TIS
E
SIDE OF ROUGH OPENING OF WINDOWADDITIONAL (2) #5 BAR, EXTEND 2’-0" BEYOND EACHSILL REINFORCEMENT @ WINDOW NOT SHOWN -3.
AND TOP OF WALLPROVIDE BOND BEAMS BELOW OPENINGS, TOP OF FOUNDATION,2.
PROVIDE BOND BEAMS AT 48" OC1.
NOTES:
W912
QR-1
3-R
0036
MA
RC
H 2
013