![Page 1: Development of Affordable Bioelectronic Devices Based on Soluble and Membrane Proteins 80 th ACS Colloids and Surface Science Symposium University of Colorado](https://reader037.vdocument.in/reader037/viewer/2022102808/56649e7a5503460f94b7b2d6/html5/thumbnails/1.jpg)
Development of Affordable Bioelectronic Devices Based on Soluble and Membrane Proteins
80th ACS Colloids and Surface Science Symposium
University of Colorado at Boulder June 20, 2006
Brian L. Hassler, Aaron J. Greiner, Sachin Jadhav, Neeraj Kohli, Robert M. Worden, Robert Y. Ofoli, Ilsoon Lee
Department of Chemical Engineering and Materials ScienceMichigan State UniversityEast Lansing, MI 48823
![Page 2: Development of Affordable Bioelectronic Devices Based on Soluble and Membrane Proteins 80 th ACS Colloids and Surface Science Symposium University of Colorado](https://reader037.vdocument.in/reader037/viewer/2022102808/56649e7a5503460f94b7b2d6/html5/thumbnails/2.jpg)
Outline• Motivation• Interface chemistry for both soluble and
membrane proteins• Electrochemical characterization• Experimental results• Integration with microfluidics• Conclusions
![Page 3: Development of Affordable Bioelectronic Devices Based on Soluble and Membrane Proteins 80 th ACS Colloids and Surface Science Symposium University of Colorado](https://reader037.vdocument.in/reader037/viewer/2022102808/56649e7a5503460f94b7b2d6/html5/thumbnails/3.jpg)
Motivation• Rapid detection• Multi-analyte identification• High throughput screening for the
pharmaceutical industry• Identification of pathogens• Affordable fabrication
![Page 4: Development of Affordable Bioelectronic Devices Based on Soluble and Membrane Proteins 80 th ACS Colloids and Surface Science Symposium University of Colorado](https://reader037.vdocument.in/reader037/viewer/2022102808/56649e7a5503460f94b7b2d6/html5/thumbnails/4.jpg)
Interface for dehydrogenase enzymes
• Mediator integration Linear approach
• Electron mediator Pyrroloquinoline quinone (PQQ)
ENZ
MED
ne-
ne-
GOLD
ENZ MED
ne-
ne-
GOLD
• Mediator integration Linear approach Branched approach
• Electron mediators Neutral red Nile blue A Toluidine blue O
ENZ MED
ne-
ne-
GOLDZayats et al., Journal of the American Chemical
Society, 124, 14724-15735 (2002)
![Page 5: Development of Affordable Bioelectronic Devices Based on Soluble and Membrane Proteins 80 th ACS Colloids and Surface Science Symposium University of Colorado](https://reader037.vdocument.in/reader037/viewer/2022102808/56649e7a5503460f94b7b2d6/html5/thumbnails/5.jpg)
Reaction Mechanism
Hassler et. al, Biosensors and Bioelectronics, 77, 4726-4733 (2006)
![Page 6: Development of Affordable Bioelectronic Devices Based on Soluble and Membrane Proteins 80 th ACS Colloids and Surface Science Symposium University of Colorado](https://reader037.vdocument.in/reader037/viewer/2022102808/56649e7a5503460f94b7b2d6/html5/thumbnails/6.jpg)
Mobile lipid
Reservoir lipid
Spacer molecule
Membrane protein
Interface for membrane proteins
Gold electrode
Raguse et. al, Langmuir, 14, 648 (1998)
![Page 7: Development of Affordable Bioelectronic Devices Based on Soluble and Membrane Proteins 80 th ACS Colloids and Surface Science Symposium University of Colorado](https://reader037.vdocument.in/reader037/viewer/2022102808/56649e7a5503460f94b7b2d6/html5/thumbnails/7.jpg)
Outline• Motivation• Interface chemistry for both soluble and
membrane proteins• Electrochemical characterization• Experimental results• Integration with microfluidics• Conclusions
![Page 8: Development of Affordable Bioelectronic Devices Based on Soluble and Membrane Proteins 80 th ACS Colloids and Surface Science Symposium University of Colorado](https://reader037.vdocument.in/reader037/viewer/2022102808/56649e7a5503460f94b7b2d6/html5/thumbnails/8.jpg)
Chronoamperometry• Technique:
Induce step change in potential Measure current vs. time
• Parameters obtained: Electron transfer coefficients (ket) Charge (Q) Surface coverage ()
Time
Po
ten
tia
l
E1
E2
Time
Cu
rre
nt
![Page 9: Development of Affordable Bioelectronic Devices Based on Soluble and Membrane Proteins 80 th ACS Colloids and Surface Science Symposium University of Colorado](https://reader037.vdocument.in/reader037/viewer/2022102808/56649e7a5503460f94b7b2d6/html5/thumbnails/9.jpg)
Cyclic voltammetry• Technique:
Conduct potential sweep Measure current density
• Parameters obtained: Peak current
• Electrode area (A)• Scan rate (v)
• Concentration (CA)
Sensitivity Maximum turnover (TRmax) Potential
Cu
rre
nt
Time
Po
ten
tia
l
E1
E2
E1
![Page 10: Development of Affordable Bioelectronic Devices Based on Soluble and Membrane Proteins 80 th ACS Colloids and Surface Science Symposium University of Colorado](https://reader037.vdocument.in/reader037/viewer/2022102808/56649e7a5503460f94b7b2d6/html5/thumbnails/10.jpg)
Constant potential amperometry• Technique:
Set constant potential Vary analyte concentration
• Parameters obtained: Sensitivity (slope)
Time
Cu
rre
nt
Concentration
Cu
rre
nt
![Page 11: Development of Affordable Bioelectronic Devices Based on Soluble and Membrane Proteins 80 th ACS Colloids and Surface Science Symposium University of Colorado](https://reader037.vdocument.in/reader037/viewer/2022102808/56649e7a5503460f94b7b2d6/html5/thumbnails/11.jpg)
Impedance spectroscopy• Technique:
Apply sinusoidal AC voltage (Vac) on top of a constant DC voltage (Vdc):
Measure resistance
• Parameters obtained: Membrane capacitance (CM)
Membrane resistance (RM)
Vapplied = Vdc + Vac sin ωt
![Page 12: Development of Affordable Bioelectronic Devices Based on Soluble and Membrane Proteins 80 th ACS Colloids and Surface Science Symposium University of Colorado](https://reader037.vdocument.in/reader037/viewer/2022102808/56649e7a5503460f94b7b2d6/html5/thumbnails/12.jpg)
Model equivalent circuit
RM: Resistance of the membrane containing the ion channels
CM: Capacitance of membrane
RS: Resistance of the solution
CDL: Double layer capacitance
RS
CM
RM
CDL
![Page 13: Development of Affordable Bioelectronic Devices Based on Soluble and Membrane Proteins 80 th ACS Colloids and Surface Science Symposium University of Colorado](https://reader037.vdocument.in/reader037/viewer/2022102808/56649e7a5503460f94b7b2d6/html5/thumbnails/13.jpg)
Outline• Motivation• Interface chemistry for both soluble and
membrane proteins• Electrochemical characterization• Experimental results• Integration with microfluidics• Conclusions
![Page 14: Development of Affordable Bioelectronic Devices Based on Soluble and Membrane Proteins 80 th ACS Colloids and Surface Science Symposium University of Colorado](https://reader037.vdocument.in/reader037/viewer/2022102808/56649e7a5503460f94b7b2d6/html5/thumbnails/14.jpg)
Experimental protocol• Secondary alcohol dehydrogenase (2 ADH)• Bacteria: Thermoanaerobacter ethanolicus
Thermostable Cofactor dependent
• Reaction mechanism
2-Propanol+NADP+ Acetone +NADPH
MEDOX+NADPH MEDRED+NADP+
MEDRED MEDOX
2 ADH
![Page 15: Development of Affordable Bioelectronic Devices Based on Soluble and Membrane Proteins 80 th ACS Colloids and Surface Science Symposium University of Colorado](https://reader037.vdocument.in/reader037/viewer/2022102808/56649e7a5503460f94b7b2d6/html5/thumbnails/15.jpg)
Chronoamperometry results• Cofactor: NADP+
• Equation:et etI = k Qexp(-k t)
ket= 4.8×102 s-1
= 2.1×10-11 mol cm-2
-2.50E-05
2.50E-05
7.50E-05
1.25E-04
1.75E-04
0 0.01 0.02 0.03 0.04 0.05
Time (s)
Cu
rren
t (A
)
Zayats et al., Journal of the American Chemical Society, 124, 14724-15735 (2002)
![Page 16: Development of Affordable Bioelectronic Devices Based on Soluble and Membrane Proteins 80 th ACS Colloids and Surface Science Symposium University of Colorado](https://reader037.vdocument.in/reader037/viewer/2022102808/56649e7a5503460f94b7b2d6/html5/thumbnails/16.jpg)
Cyclic voltammetry results• Concentration range: 5 – 25 mM• Sensitivity: 3.8 A mM-1 cm-2
• TRmax=37 s-1
-30
-20
-10
0
10
20
30
-2000200400
Voltage (mV)
Cu
rren
t (
A)
0
5
10
15
20
25
0 10 20 30Concentration (mM)
Cu
rren
t (
A)
![Page 17: Development of Affordable Bioelectronic Devices Based on Soluble and Membrane Proteins 80 th ACS Colloids and Surface Science Symposium University of Colorado](https://reader037.vdocument.in/reader037/viewer/2022102808/56649e7a5503460f94b7b2d6/html5/thumbnails/17.jpg)
Amperometric detection• Potential: -200 mV• Concentration range: 1-6 mM• Sensitivity: 2.81 A mM-1 cm-2
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
0 20 40Time (s)
Cu
rre
nt
(A
)
0
1
2
3
4
0 2 4 6 8
Concentration (mM)
Cu
rren
t ( A
)
![Page 18: Development of Affordable Bioelectronic Devices Based on Soluble and Membrane Proteins 80 th ACS Colloids and Surface Science Symposium University of Colorado](https://reader037.vdocument.in/reader037/viewer/2022102808/56649e7a5503460f94b7b2d6/html5/thumbnails/18.jpg)
Impedance spectroscopy• Membrane capacitance: 1.17 µF cm-2
• Membrane resistance: 0.68 M cm2
• Resistance with valinomycin: 0.19 M cm2
4.5
4.7
4.9
5.1
5.3
5.5
5.7
5.9
-2 -1 0 1
Log(freq) (Hz)
Lo
g Z
(
)
After addition of valinomycin
Before addition of valinomycin
![Page 19: Development of Affordable Bioelectronic Devices Based on Soluble and Membrane Proteins 80 th ACS Colloids and Surface Science Symposium University of Colorado](https://reader037.vdocument.in/reader037/viewer/2022102808/56649e7a5503460f94b7b2d6/html5/thumbnails/19.jpg)
Outline• Motivation• Interface chemistry for both soluble and
membrane proteins• Electrochemical characterization• Experimental results• Integration with microfluidics• Conclusions
![Page 20: Development of Affordable Bioelectronic Devices Based on Soluble and Membrane Proteins 80 th ACS Colloids and Surface Science Symposium University of Colorado](https://reader037.vdocument.in/reader037/viewer/2022102808/56649e7a5503460f94b7b2d6/html5/thumbnails/20.jpg)
Motivation for use of microfluidics• Precise control over channel geometry• Precise control over flow conditions• Small sample volumes• Ease of fabrication using PDMS
![Page 21: Development of Affordable Bioelectronic Devices Based on Soluble and Membrane Proteins 80 th ACS Colloids and Surface Science Symposium University of Colorado](https://reader037.vdocument.in/reader037/viewer/2022102808/56649e7a5503460f94b7b2d6/html5/thumbnails/21.jpg)
Integration with microfluidics• Soft lithography• Channel dimensions: (300µm x 35µm)
Si
PDMS
Glass
PDMS
![Page 22: Development of Affordable Bioelectronic Devices Based on Soluble and Membrane Proteins 80 th ACS Colloids and Surface Science Symposium University of Colorado](https://reader037.vdocument.in/reader037/viewer/2022102808/56649e7a5503460f94b7b2d6/html5/thumbnails/22.jpg)
Layout of microfluidics system
Working Electrodes
Auxiliary Electrode
Inlet Outlet
Torque-Actuated Valves
Inlet/Outlet Ports
Microfluidic Channels
![Page 23: Development of Affordable Bioelectronic Devices Based on Soluble and Membrane Proteins 80 th ACS Colloids and Surface Science Symposium University of Colorado](https://reader037.vdocument.in/reader037/viewer/2022102808/56649e7a5503460f94b7b2d6/html5/thumbnails/23.jpg)
Torque-actuated valves
Glass
PDMS
Urethane
Whitesides et al., Analytical Chemistry, 77, 4726-4733 (2005)
![Page 24: Development of Affordable Bioelectronic Devices Based on Soluble and Membrane Proteins 80 th ACS Colloids and Surface Science Symposium University of Colorado](https://reader037.vdocument.in/reader037/viewer/2022102808/56649e7a5503460f94b7b2d6/html5/thumbnails/24.jpg)
Zayats model
![Page 25: Development of Affordable Bioelectronic Devices Based on Soluble and Membrane Proteins 80 th ACS Colloids and Surface Science Symposium University of Colorado](https://reader037.vdocument.in/reader037/viewer/2022102808/56649e7a5503460f94b7b2d6/html5/thumbnails/25.jpg)
Torque-actuated valves
![Page 26: Development of Affordable Bioelectronic Devices Based on Soluble and Membrane Proteins 80 th ACS Colloids and Surface Science Symposium University of Colorado](https://reader037.vdocument.in/reader037/viewer/2022102808/56649e7a5503460f94b7b2d6/html5/thumbnails/26.jpg)
Torque-actuated valves
![Page 27: Development of Affordable Bioelectronic Devices Based on Soluble and Membrane Proteins 80 th ACS Colloids and Surface Science Symposium University of Colorado](https://reader037.vdocument.in/reader037/viewer/2022102808/56649e7a5503460f94b7b2d6/html5/thumbnails/27.jpg)
Outline• Motivation• Interface chemistry for both soluble and
membrane proteins• Electrochemical characterization• Experimental results• Integration with microfluidics• Conclusions
![Page 28: Development of Affordable Bioelectronic Devices Based on Soluble and Membrane Proteins 80 th ACS Colloids and Surface Science Symposium University of Colorado](https://reader037.vdocument.in/reader037/viewer/2022102808/56649e7a5503460f94b7b2d6/html5/thumbnails/28.jpg)
Conclusions• Developed self-assembling biosensor interfaces
Dehydrogenases Ionophores
• Characterized interfaces electrochemically Chronoamperometry Cyclic voltammetry Constant potential amperometry Impedance spectroscopy
• Fabricated electrode arrays with microfluidics Photolithography Soft lithography Torque-actuated valves
![Page 29: Development of Affordable Bioelectronic Devices Based on Soluble and Membrane Proteins 80 th ACS Colloids and Surface Science Symposium University of Colorado](https://reader037.vdocument.in/reader037/viewer/2022102808/56649e7a5503460f94b7b2d6/html5/thumbnails/29.jpg)
Acknowledgments• Yue Huang:
Electrical Engineering (MSU)
• Dr. J. Gregory Zeikus: Biochemistry and Molecular Biology (MSU)
• Ted Amundsen Chemical Engineering (MSU)
![Page 30: Development of Affordable Bioelectronic Devices Based on Soluble and Membrane Proteins 80 th ACS Colloids and Surface Science Symposium University of Colorado](https://reader037.vdocument.in/reader037/viewer/2022102808/56649e7a5503460f94b7b2d6/html5/thumbnails/30.jpg)
Thank you
Questions?