DIAGRAMAS Y PLANOS
APARTADO 10
NYLON 66 by ARROL
PLANTA DE PRODUCCIÓN DE CUMENO
PLANOS Y DIAGRAMAS
2
10 PLANOS Y DIAGRAMAS ...............................................................................................................................
10.1 NOMENCLATURA ..................................................................................................................................
10.1.1 VÁLVULAS Y ACCESORIOS .............................................................................................................
10.1.2 EQUIPOS ............................................................................................................................................
10.2 DIAGRAMAS ...........................................................................................................................................
Plano nº1 Diagrama de flujo ............................................................................................................................
Plano nº2 Diagrama de proceso .....................................................................................................................
10.3 P&ID ........................................................................................................................................................
Plano nº1 A-100 ..............................................................................................................................................
Plano nº2 A-200 ..............................................................................................................................................
Plano nº3 A-300 ..............................................................................................................................................
Plano nº4 A-400 ............................................................................................................................................. .
Plano nº5 A-1600 & A-500 ..............................................................................................................................
10.4 IMPLANTACIÓN ......................................................................................................................................
Plano nº1 A-100a ............................................................................................................................................
Plano nº2 A-100b ............................................................................................................................................
Plano nº3 A-200 ..............................................................................................................................................
Plano nº4 A-300 ..............................................................................................................................................
Plano nº5 A-400a ............................................................................................................................................
Plano nº6 A-400b ............................................................................................................................................
Plano nº7 A-1600 ............................................................................................................................................
10.5 PLANOS ..................................................................................................................................................
Plano nº1 Zonas en Nylon 66..........................................................................................................................
Plano nº2 Equipos en Nylon 66.......................................................................................................................
Plano nº3 Incendios en Nylon 66 ....................................................................................................................
Válvulas y accesorios
Símbolo Descripción
Flujos
PLANOS Y DIAGRAMAS 10
NOMENCLATURA10.1
VÁLVULAS Y ACCESORIOS10.1.1 Pág.3
Símbolo Descripción
Bomba
PLANOS Y DIAGRAMAS 10
NOMENCLATURA10.1
EQUIPOS10.1.2 Pág.4
Plano de:Dibujado: Dep. PlanificaciónRevisado: Dep. Calidad
Aprovado: Dirección Técnica
Fecha proyecto: 15-01-2015
Proyeto: NYLON 66
Plano nº: Descripción:
Diagramade flujo1
BenzenoPropileno
MEZCLA
COMPRESIÓN
REACCIÓN
CATALÍTICA
COMPRESIÓN
DES-
COMPRESIÓN
TRATAMIENTO
TÉRMICOSEPARACIÓN RECTIFICACIÓN RECTIFICACIÓN
MEZCLA
Cumeno
DIPB
Electricidad
Therminol 66Electricidad
Benzeno recirculado
Therminol 66
Therminol 66
Therminol 66
Agua d
e t
orr
eA
gua
Gas fuel
Benzeno r
ecircula
do
Agua Agua de chiller
Agua
Ag
ua d
e torr
e
Th
erm
inol 66
Therm
inol 66
Agua de chillerAgua
AguaTherminol 66
Agua de torreTherminol 66
TRATAMIENTO
TÉRMICO
TRATAMIENTO
TÉRMICO
TRATAMIENTO
TÉRMICO
TRATAMIENTO
TÉRMICO
TRATAMIENTO
TÉRMICO
Electricidad
Plano de:
Diagramade proceso
Dibujado: Dep. Planificación
Revisado: Dep. Calidad
Aprovado: Dirección Técnica
Fecha proyecto: 15-01-2015
Proyeto: NYLON 66
Plano nº: Descripción:
2
BENCENO
PROPILENO
FUEL GAS
16
13
PROPIEDADESCORRIENTE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
Temperatura (ºC) 25.00 168.90 25.00 53.88 38.55 100.70 235.10 213.60 322.90 360.00 427.00 325.40 264.50 90.00 90.00 90.00 176.50 175.90 235.00 25.00 25.00
Densidad(Kg/m3) 520.19 520.19 882.13 863.08 873.54 873.54 874.54 749.64 749.64 749.64 839.11 839.11 839.11 839.11 677.47 864.00 864.84 864.70 859.81 864.70 859.81
Presión (bar) 1.75 25.00 1.75 1.75 1.75 1.75 25.00 25.00 25.00 25.00 25.00 24.80 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75
Estado físico V V L L L V V V V V V V V L/V V L L L L L L
CAUDALES MÁSICOS (Kg/h)Propileno 4808.90 4808.90 285.01 286.65 286.65 286.65 7585.25 7585.25 7585.25 1864.57 1864.57 1864.57 1864.57 973.92 367.29
Propano 253.10 253.10 108.85 110.25 110.25 110.25 478.64 478.64 478.64 684.65 684.65 684.65 684.65 354.19 140.98
Benceno 8584.00 6624.64 15209.78 15209.78 15209.78 12627.50 12627.50 12627.50 9243.80 9243.80 9243.80 9243.80 831.79 8525.58
Cumeno 142.50 143.33 143.33 143.33 118.62 118.62 118.62 8860.90 8860.00 8860.00 8860.90 95.88 9349.20 11186.12 11118.89 0.14 11118.89 0.14
DIPB 156,08 156,08 156,08 156,08 0.23 166.95 203,88 1.11 271.56 1.11 271.56
Total 5062.00 5062.00 8584.00 7161.00 15750.00 15750.00 15750.00 20810.00 20810.00 20810.00 20810.00 20809.10 20809.10 20810.00 2256.01 18550.00 11390.00 11120.00 271.70 11120.00 271.70
15
14
17
4
2
8
9
10
1112
E-203
R-201
E-202
E-301
C-301
C-302
Br-301
E-302
E-304
7
Co-201
Co-101
E-201
CUMENO
DIPB
18
19
C-303
E-305
Br-302
E-303
20
21
E-307
E-306
M-201
H2H1
H5
H4
C2
C1
C3
C4
H7
H6
H9
H8
C5
C6
C7 C8
C9 C10
SERVICIO FRÍOCORRIENTE C1 C2 C3 C4 C5 C6 C7 C8 C9 C10
Temperatura (ºC) 30 40 30 40 30 40 15 30 15 30
Caudal (Kg/h) 284009 284009 108813 108813 134636 134636 55703 55703 110567 110567
Capacidad calorífica (KJ/Kg·ºC) 4.52 4.52 4.52 4.52 4.52 4.52 4.52 4.52 4.52 4.52
Producto Agua Agua Agua Agua Agua Agua Agua Agua Agua Agua
Origen/Destino Torre Torre Torre Torre Torre Torre Chiller Chiller Chiller Chiller
SERVICIO CALORCORRIENTE H1 H2 H3 H4 H5 H6 H7 H8 H9
Temperatura (ºC) 300.00 240.00 300.00 365.00 340.00 300.00 223.00 300.00 250.00
Caudal (Kg/h) 43200 43200 17016 17016 17016 30000 30000 44703 44703
Capacidad calorífica (KJ/Kg·ºC) 2.96 2.75 2.96 3.20 3.11 2.96 2.69 2.96 2.79
Producto Th 66 Th 66 Th 66 Th 66 Th 66 Th 66 Th 66 Th 66 Th 66
Origen/Destino Caldera Caldera Caldera Reactor Caldera Caldera Caldera Caldera Caldera
H3
1
3
56
Plano de:
P&IDA-100
Dibujado: Dep. PlanificaciónRevisado: Dep. Calidad
Aprovado: Dirección Técnica
Fecha proyecto: 15-01-2015
Proyeto: NYLON 66
Plano nº: Descripción:
1
A-500
A-200
PROPILENO
BENCENO
A-200
LCV2L-T103-1
LICL-T103-1
LCV1L-T103-1
LTL-T103-1
LEL-T103-1
LCV2L-T104-1
LICL-T104-1
LCV1L-T103-1
LTL-T104-1
LEL-T104-1
LCV2L-T101-1
LICL-T101-1
LCV1L-T101-1
LTL-T101-1
LEL-T101-1
LCV2L-T102-1
LICL-T102-1
LCV1L-T102-1
LTL-T102-1
LEL-T102-1
LEL-T103-2
LTL-T103-2
LICL-T103-2
LCVL-T103-2
LEL-T104-2
LTL-T104-2
LICL-T104-2
LCVL-T104-2
LEL-T102-2
LTL-T102-2
LICL-T102-2
LCVL-T102-2
LEL-T101-2
LTL-T101-2
LICL-T101-2
LCVL-T101-2
PIPI-T101
PIPI-T101
T-102T-101
T-104T-103
4"-AI2-M-127
2"-AI2-M-101
2"-AI2-TV-110
2"-AI2-AS-102
2"-AI2-B-103 2"-AI2-B-104
2"-AI2-AS-105
2"-AI2-AS-106
2"-AI2-B-107 2"-AI2-B-108
2"-AI2-AS-109
2"-AI2TV-111
2"-AI2-AS-112
2"-AI2-B-113 2"-AI2-B-114
2"-AI2-AS-115
2"-AI2-AS-116
2"-AI2-B-117 2"-AI2-B-118
2"-AI2-AS-119
2"-AI2-TV-120
2"-AI2-B-121 2"-AI2-B-123
2"-AI2-R-122
2"-AI2-B-124 2"-AI2-B-126
2"-AI2-R-125
2"-AI2-F-101
2"-AI2-F-102
4"-AI2-TV-136
4"-AI2-AS-128
4"-AI2-B-129 4"-AI2-B-130
4"-AI2-AS-131
4"-AI2-AS-132
4"-AI2-B-133 4"-AI2-B-134
4"-AI2-AS-135
4"-AI2-TV-137
4"-AI2-AS-138
4"-AI2-B-139 4"-AI2-B-140
4"-AI2-AS-141
4"-AI2-AS-142
4"-AI2-B-143 4"-AI2-B-144
4"-AI2-AS-145
4"-AI2-TV-146
4"-AI2-M-1474"-AI2-M-149
4"-AI2-R-148
4"-AI2-M-150 4"-AI2-M-152
4"-AI2-R-151
4"-AI2-F-103
4"-AI2-F-104
2"-AI2CSP1-BC-101 2"-AI2CSP1-BC-102
2"-A
I2C
SP
2-B
C-1
03
2"-A
I2C
SP
1-B
C-1
05
2"-AI2CSP1-BC-104
2"-AI2CSP1-BC-106
2"-AI2CSP1-BC-108
2"-A
I2C
SP
1-B
C-1
07
4"-AI2CSP5-PRP-110 4"-AI2CSP5-PRP-111
4"-A
I2C
SP
5-P
RP
-11
2
4"-AI2CSP5-PRP-113
4"-A
I2C
SP
5-P
RP
-11
4
4"-AI2CSP5-PRP-115
4"-AI2CSP6-PRP-117
4"-A
I2C
SP
5-P
RP
-11
6
P-101-A
P-101-B
CO-101-A
CO-101-B
AT
MÓ
SF
ER
A
AT
MÓ
SF
ER
A
Plano de:
P&IDA-200
Dibujado: Dep. Planificación
Revisado: Dep. Calidad
Aprovado: Dirección Técnica
Fecha proyecto: 15-01-2015
Proyeto: NYLON 66
Plano nº: Descripción:
2
A-100
A-3
00
A-100
A-300
LEL-M201
LTL-M201
LICL-M201
LCVL-M201
TCVT-E201
TICT-E201
TTT-E201
TET-E201
TCVT-E203
TICT-E203
TTT-E203
TET-E203
M-201
E-203
E-201E-202
2"-A
I2-B
-23
1
2"-AI2-AS-204
2"-AI2-M-2022"-AI2-M-203
2"-AI2-AS-201
2,5
"-AI2
-B-2
05
2,5
"-AI2
-B-2
092,5
"-AI2
-F-2
02
2,5
"-AI2
-B-2
102,5
"-AI2
-B-2
11
2,5
"-AI2
-B-2
062,5
"-AI2
-F-2
01
2,5
"-AI2
-R-2
072,5
"-AI2
-B-2
08
P-2
01
-A
P-2
01
-B
8"-A
I2-B
-21
2
8"-AI2-M-213
8"-AI2-F-203
8"-AI2-F-204
8"-AI2-M-214
4"-AI2-M-216
4"-AI2-M-218
4"-AI2-R-215
4"-AI2-M-217
4"-A
I2-B
-21
94
"-AI2
-B-2
20
4"-A
I2-B
-22
1
6"-A
I2-B
-22
2
6"-AI2-B-223
6"-AI2-B-224
4"-A
I2-B
-22
5
5"-AI2-M-230
CO-201-A
CO-201-B
2"-AI2CSP1-BC-201
2,5
"-AI2
CS
P1
-BC
-20
2
8"-AI2CSP1-BC-203
4"-AI2CSP6-PPB-205
4"-AI2CSP6-PRP-211
6"-A
I2C
SP
6-P
PB
-20
6
4"-AI2CSP6-BC-204
6"-A
I2C
SP
6-P
PB
-20
7
4"-AI2CSP6-CDPB-208
5"-AI2CSP6-CDPB-209
2"-AI2CSP1-BC-210
CEC-R201
CTC-R201
CITC-R201
CCVC-R201
4"-AI2-M-227 4"-AI2-M-228
4"-AI2-AS-229
4"-AI2-AS-226
PCWP-CO-201A/B
PICP-CO-201A/B
PTP-CO-201A/B
PEP-CO-201A/B
PIPI-E202
PIPI-E203
PIPI-E201
R-2
01
CO
L. C
ALD
ER
A
COL. CALDERA
CA
LD
ER
A
TCVT-R201
TICT-R201
TTT-R201
TET-R201
R-201
PIPI-R201
CALDERA
E-203
Plano de:
P&IDA-300
Dibujado: Dep. Planificación
Revisado: Dep. Calidad
Aprovado: Dirección Técnica
Fecha proyecto: 15-01-2015
Proyeto: NYLON 66
Plano nº: Descripción:
3
A-4
00
A-200
TCVT-E301
TICT-E301
TTT-E301
TET-E301
LEL-C301
LTL-C301
LICL-C301
TCVT-E302
TICT-E302
TTT-E302
TET-E302
LEL-C302
LTL-C302
LICL-C302
LCVL-C302
TICT-E307
TET-E307
TTT-E307
TVCT-E307
E-302
C-303
E-305E-304
E-301
E-307
TICT-E306
TVCT-E306
TTT-E306
TET-E306
TICT-C302
TTT-C302
TET-C302
TCVT-C302
LEL-C303
LTL-C303
LICL-C303
LCVL-C303
PCVP-C302
PICP-C302
PTP-C302
PEP-C302
TCVT-E303
TICT-E303
TTT-E303
TET-E303
PCVP-E303
PICP-E303
PTP-E303
PEP-E303
TICT-C303
TTT-C303
TET-C303
TCVT-C303
Br-301
LEL-BR302
A-4
00
Br-302
LTL-BR302
LICL-BR302
LCVL-BR302
LEL-BR301
LTL-BR301
LICL-BR301
LCVL-BR301
LCVL-C301
E-303
A-500
A-2
00
C-301
C-302
E-306
5"-A
I2C
SP
6-C
DP
B-3
01
5"-AI2-B-301
5"-AI2-B-302
5"-A
I2C
SP
1-C
DP
B-3
02
5"-AI2-B-303
3"-AI2-M-305 3"-AI2-M-306
3"-AI2-AS-307
3"-AI2-AS-304
3"-AI2-B-308 3"-AI2-R-310
3"-AI2-B-311
3"-AI2-F-301
3"-AI2-B-309 3"-AI2-R-312
3"-AI2-B-313
3"-AI2-F-302
P-301-B
P-301-A
2"-AI2-B-314
2"-AI2-R-315
2"-AI2-B-316
2"-AI2-F-303
2"-AI2-B-319
2"-AI2-R-318
2"-AI2-B-317
2"-AI2-F-304
P-302-B
P-302-A
2"-A
I2-M
-32
0
2"-AI2-M-322 2"-AI2-M-324
2"-AI2-AS-323
2"-AI2-AS-321
2"-AI2-M-326 2"-AI2-M-328
2"-AI2-AS-327
2"-AI2-AS-325
2"-AI2-B-331
2"-AI2-R-330
2"-AI2-B-329
2"-AI2-F-305
2"-AI2-B-334
2"-AI2-R-333
2"-AI2-B-332
2"-AI2-F-306
P-303-B
P-303-A
2,5
"-AI2
-M-3
35
2,5
"-AI2
-M-3
36
2,5"-AI2-M-338 2,5"-AI2-M-339
2,5"-AI2-AS-340
2,5"-AI2-AS-337
2,5"-AI2-B-341 2,5-AI2-R-342
2,5"-AI2-B-343
2,5"-AI2-F-307
2,5"-AI2-B-344 2,5"-AI2-R-345
2,5"-AI2-B-346
2,5"-AI2-F-308
P-304-B
P-304-A
2,5"-AI2-B-347
2,5"-AI2-R-348
2,5"-AI2-B-349
2,5"-AI2-F-309
2,5"-AI2-B-352
2,5"-AI2-R-351
2,5"-AI2-B-350
2,5"-AI2-F-310
P-305-B
P-305-A
2,5
"-AI2
-M-3
53
2,5"-AI2-M-355 2,5"-AI2-M-357
2,5"-AI2-AS-356
2,5"-AI2-AS-354
2,5"-AI2-M-359 2,5"-AI2-M-360
2,5"-AI2-AS-361
2,5"-AI2-AS-358
3/8
"-AI2
-M-3
68
3/8
"-AI2
-M-3
69
3/8"-AI2-M-371 3/8"-AI2-M-372
3/8"-AI2-AS-373
3/8"-AI2-AS-370
2,5"-AI2-B-364
2,5"-AI2-R-363
2,5"-AI2-B-362
2,5"-AI2-F-311
2,5"-AI2-B-367
2,5"-AI2-R-366
2,5"-AI2-B-365
2,5"-AI2-F-312
P-306-B
P-306-A
3/8"-AI2-B-374 3/8"-AI2-R-375
3/8"-AI2-B-376
2,5"-AI2-F-307
3/8"-AI2-B-377 3/8"-AI2-R-378
3/8"-AI2-B-379
2,5"-AI2-F-308
P-307-B
P-307-A
2,5"-AI2-B-381
3/8
"-AI2
-B-3
80
5"-AI2CSP6-CDPB-303
3"-A
I2C
SP
1-C
DP
B-3
04
2,5
"-AI2
CS
P1
-CD
PB
-30
8
2"-AI2CSP1-BC-306A
2"-A
I2C
SP
1-B
C-3
07
2,5
"-AI2
CS
P1
-CD
PB
-30
5A
3/8
"-AI2
CS
P1
-DIP
B-3
09A
2,5
"-AI2
CS
P1
-CD
PB
-30
5B
2"-AI2CSP1-BC-306B
3/8
"-AI2
CS
P1
-DIP
B-3
09
B
3/8
"-AI2
CS
P1
-DIP
B-3
10
2,5"-AI2CSP1-CU-311A
2,5"-AI2CSP1-CU-311B
2,5"-AI2CSP1-CU-312
PEP-E301
PTP-E301
PITP-E301
PCVP-E301
5"-AI2-M-3925"-AI2-M-393
5"-AI2-AS-391
5"-AI2-AS-390
CEC-BR301
CTC-BR301
CICC-BR301
CCVC-BR301
2"-AI2-M-3842"-AI2-M-385
2"-AI2-AS-383
2"-AI2-AS-382
CEC-BR302
CTC-BR302
CICC-BR302
CCVC-BR302
2,5"-AI2-M-3882,5"-AI2-M-389
2,5"-AI2-AS-387
2,5"-AI2-AS-386
COL. CALDERA COL. CALDERA
CA
LD
ER
A
CA
LD
ER
A
TORRES TO
RR
ES
TO
RR
ES
COL. TORRES COL. TORRES
CO
L. T
OR
RE
S
CHILLERS
CHILLERS
COL. CHILLERS
COL. CHILLERS
Plano de:
P&IDA-400
Dibujado: Dep. PlanificaciónRevisado: Dep. Calidad
Aprovado: Dirección Técnica
Fecha proyecto: 15-01-2015
Proyeto: NYLON 66
Plano nº: Descripción:
4
A-700
CUMENO de
A-300ACENOL
LCV2L-T401-1
LICL-T401-1
LCV1L-T401-1
LTL-T401-1
LEL-T401-1
LCV2L-T402-1
LICL-T402-1
LCV1L-T402-1
LTL-T402-1
LEL-T402-1
LCV2L-T401-2
LICL-T401-2
LTL-T401-2
LEL-T401-2
LCV2L-T402-2
LICL-T402-2
LTL-T402-2
LEL-T402-2
LICL-T403-1
LCV1L-T403-1
LTL-T403-1
LEL-T403-1
LCV2L-T403-2
LICL-T403-2
LTL-T403-2
LEL-T403-2
DIPB de A-300
A-700
2,5"-AI2-TV-401A
2,5"-AI2-AS-402
2,5"-AI2-B-403 2,5"-AI2-B-404
2,5"-AI2-AS-405
2,5"-AI2-AS-406
2,5"-AI2-B-407 2,5"-AI2-B-408
2,5"-AI2-AS-409
2"-AI2TV-401B
2,5"-AI2-AS-410
2,5"-AI2-B-411 2,5"-AI2-B-412
2,5"-AI2-AS-413
2,5"-AI2-AS-414
2,5"-AI2-B-415 2,5"-AI2-B-416
2,5"-AI2-AS-417
2,5"-AI2-TV-418
2,5"-AI2CSP1-CM-401 2,5"-AI2CSP1-CM-403
2,5
"-AI2
CS
P1
-CM
-40
2
2,5
"-AI2
CS
P1
-CM
-40
5
2,5"-AI2CSP1-CM-404
2,5"-AI2CSP1-CM-406
3/8"-AI2-AS-419
3/8"-AI2-B-420 3/8"-AI2-B-421
3/8"-AI2-AS-422
3/8"-AI2-AS-423
3/8"-AI2-B-424 3/8"-AI2-B-425
3/8"-AI2-AS-426
3/8"-AI2CSP1-DP-409
2,5"-AI2CSP1-CM-407
3/8"-AI2CSP1-DP-410
AT
MÓ
SF
ER
A
AT
MÓ
SF
ER
A
2,5"-AI2-B-427 2-AI2-R-426
2"-AI2-B-429
2,5"-AI2-F-401
2,5"-AI2-B-430 2"-AI2-R-431
2"-AI2-B-432
2,5"-AI2-F-402
P-401-B
P-401-A
2"-AI2CSP1-CM-408
ATMÓSFERA
Plano de:
P&IDEJEMPLO A-1600 & A-500
Dibujado: Dep. PlanificaciónRevisado: Dep. Calidad
Aprovado: Dirección Técnica
Fecha proyecto: 15-01-2015
Proyeto: NYLON 66
Plano nº: Descripción:
5
Producción de aire comprimido
Circuito aceite térmico
Quemador de gases
PEP-RC-2
COLECTOR
PTP-RC-2
PICP-RC-2
PCVP-RC-2
PEP-RC-1
PTP-RC-1
PICP-RC-1
PCVP-RC-1
PdI
LAL
PdI
AT
MÓ
SF
ER
A
AIRE
GA
S N
AT
UR
AL
AIRE
GAS NATURAL
C.THERMINOL 66
THERMINOL 66
AIRE
Plano de:
ImplantaciónA-100a
Dibujado: Dep. Planificación
Revisado: Dep. Calidad
Aprovado: Dirección Técnica
Fecha proyecto: 15-01-2015
Proyeto: NYLON 66
Plano nº: Descripción:
1
T-101 T-102
Plano de:
ImplantaciónA-100b
Dibujado: Dep. Planificación
Revisado: Dep. Calidad
Aprovado: Dirección Técnica
Fecha proyecto: 15-01-2015
Proyeto: NYLON 66
Plano nº: Descripción:
2
T-103 T-104
Plano de:
ImplantaciónA-200
Dibujado: Dep. Planificación
Revisado: Dep. Calidad
Aprovado: Dirección Técnica
Fecha proyecto: 15-01-2015
Proyeto: NYLON 66
Plano nº: Descripción:
3
E-203 E-202
E-201
M-201
R-201
Plano de:
ImplantaciónA-300
Dibujado: Dep. Planificación
Revisado: Dep. Calidad
Aprovado: Dirección Técnica
Fecha proyecto: 15-01-2015
Proyeto: NYLON 66
Plano nº: Descripción:
4
E-301Br-301
E-304 E-305
Br-302
C-301 C-302 C-303
E-302 E-303
E-307
E-306
Plano de:
ImplantaciónA-400a
Dibujado: Dep. Planificación
Revisado: Dep. Calidad
Aprovado: Dirección Técnica
Fecha proyecto: 15-01-2015
Proyeto: NYLON 66
Plano nº: Descripción:
5
T-401 T-402
Plano de:
ImplantaciónA-400b
Dibujado: Dep. Planificación
Revisado: Dep. Calidad
Aprovado: Dirección Técnica
Fecha proyecto: 15-01-2015
Proyeto: NYLON 66
Plano nº: Descripción:
6
T-403
Plano de:
ImplantaciónA-1600
Dibujado: Dep. Planificación
Revisado: Dep. Calidad
Aprovado: Dirección Técnica
Fecha proyecto: 15-01-2015
Proyeto: NYLON 66
Plano nº: Descripción:
7
TR-1601
TR-1602
TR-1605
TR-1604
TR-1603
CH-1601
CH-1602
CA-1601 CA-1601AI-1601
N-1601
G-1601
Plano de:
PlanoNYLON 66 Zonas
Dibujado: Dep. PlanificaciónRevisado: Dep. Calidad
Aprovado: Dirección Técnica
Fecha proyecto: 15-01-2015
Proyeto: NYLON 66
Plano nº: Descripción:
1
C/ DE LA POLIAMIDA
C/ DEL CICLOHEXA
AV
ING
UD
A D
EL
NIT
RIC
A-1200 (MANTENIMIENTO PLANTA)
AMPLIACIÓN A-1400 (RECTIFICACIÓN)
AMPLIACIÓN A-1400 (REACCIÓN)
AMPLIACIÓN A-1400(PRODUCTOS)
AMPLIACIÓN A-1400(ED.CORPORATIVO)
AM
PLIA
CIÓ
N A
-1400
(LA
BO
RA
TO
RIO
S)
A-1
600
(INE
RT
IZA
CIÓ
N)
A-200
(REACCIÓN)
A-300
(RECTIFICACIÓN)
A-100
(ALMACENAMIENTO
MATERIAS PRIMERAS)
A-400
(ALMACENAMIENTO
PRODUCTO FINAL)
A-700
(CARGA Y
DESCARGA)
A-900a
(LABORATORIO
CALIDAD)
A-900a
(SALA CAMPANAS)
A-900b
(LABORATORIO
PROCESO)
A-900b
(SALA CAMPANAS)
A-1600
(GASES
LABORATORIO)
A-1000
(VESTUARIOS)
A-1200
(SERVICIO
LIMPIEZA
EDIFICIOS)
A-1000
(COCINA
COMEDOR)
A-1000
(SALA
FORMACIONES)
A-800
(OFICINAS)
A-1100
(SALA DE CONTROL)
A-800
(DIRECCIÓN)
A-1300
(APARCAMIENTO)
A-800
(RECEPCIÓN)
A-1000
(SALA
VISITAS)
A-1200
(MANTENI-
MIENTO
PLANTA)
A-1600
(SERVICIOS)
AMPLIACIÓN A-1400(SERVICIOS)
AMPLIACIÓN A-1400(SERVICIOS)
A-1400
(AMPLIACIONES)
N
A-500a
(TRATAMIENTO
GASES)
A-500b
(TRATAMIENTO
LÍQUIDOS)
A-600
(PROTECCIÓNCONTRA
INCENDIOS)
A-1500
(ESTACIÓNTRANSFORMADORA)
A-500c
(TRATAMIENTO
RESIDUOS
SÓLIDOS)
Plano de:
PlanoNYLON 66
Dibujado: Dep. Planificación
Revisado: Dep. CalidadAprovado: Dirección Técnica
Fecha proyecto: 15-01-2015
Proyeto: NYLON 66
Plano nº: Descripción:
2
C/ DE LA POLIAMIDA
C/ DEL CICLOHEXA
AV
ING
UD
A D
EL
NIT
RIC
N
VISITASVISITASVISITAS
HC A
VENTA AACENOL
Bombes
Bombes
Bombes$
Bom
bes
Bombes
Bombes
Bombes
Bombes Bombes
Plano de:
PlanoNYLON 66 Incendios
Dibujado: Dep. PlanificaciónRevisado: Dep. Calidad
Aprovado: Dirección Técnica
Fecha proyecto: 15-01-2015
Proyeto: NYLON 66
Plano nº: Descripción:
3
BOCA DEINCENDIO
HIDRANTE
EXTINTOR
HIDRANTE
SPRINKLER
BOCA DE
INCENDIOS
LEYENDA
C/ DE LA POLIAMIDA
C/ DEL CICLOHEXA
AV
ING
UD
A D
EL
NIT
RIC
N
VISITAS
AMPLIACIÓN A-1400 (RECTIFICACIÓN)
AMPLIACIÓN A-1400 (REACCIÓN)
AMPLIACIÓN A-1400(PRODUCTOS)
AMPLIACIÓN A-1400(ED.CORPORATIVO)
AM
PLIA
CIÓ
N A
-1400
VISITAS VISITAS
AMPLIACIÓN A-1400(SERVICIOS)
AMPLIACIÓN A-1400(SERVICIOS)
BOCA DEINCENDIO
BOCA DEINCENDIO
BOCA DEINCENDIO
BOCA DEINCENDIO
BOCA DEINCENDIO
BOCA DEINCENDIO
BOCA DEINCENDIO
BOCA DEINCENDIO
BOCA DEINCENDIO
BOCA DEINCENDIO
BOCA DEINCENDIO
BOCA DEINCENDIO
HIDRANTE
HIDRANTE
HIDRANTE
HIDRANTE
HIDRANTE
HIDRANTE
HIDRANTEHIDRANTE
HIDRANTEHIDRANTEHIDRANTE
HIDRANTEHIDRANTE
HIDRANTE
HIDRANTE
HIDRANTE
HIDRANTE
HIDRANTE
HIDRANTEHIDRANTE
HIDRANTEHIDRANTE HIDRANTE
HC A