Field device for DLC-2000 System Communication via different media high, medium and low voltage power-
lines special distribution lines (e.g.
emergency power supply lines) long distance or heavily disturbed 2-
wire line data rates up to 576 kbps regulation compliant communication
(CENELEC / FCC)
DLC-200 Node
DLC-200 Node
Technical Data Frequency Range Further Features 9 – 500 kHz - carrier frequencies freely configurable - Transmission with OFDM and FEC Freely configurable Band Width - synchronous and asynchronous transmission 4 – 400 kHz - complies with standards EN 50065 (CENELEC), IEC 61000-3, FCC part 15 Data Rates Subpart B 9.6 – 576 (288 CENELEC) kbps - Transmission via high, medium and low voltage or any two-wire line (even heavily disturbed and attenuated lines) Maximum Range without Repeater - protection class: IP51 500 m – 1 km over low voltage lines up to 15km over medium voltage lines Medium Voltage Coupling capacitive or inductive
Function The basis of the DLC-2000 system is a power line communication (PLC) infrastructure that allows to access metering and control equipment remotely. In according with the overall project goals, the primary usage of this infrastructure is remote meter reading and remote control. Besides that, the communication platform is open to various kinds of add-on services. The bottom-level of the communication infrastructure is comprised of DLC-200 Nodes, each coupled with a PLC interface (usually a low-voltage PLC device, in certain cases also with medium-voltage PLC interface). A Node is usually installed at the consumer site, e.g., inside an apartment, and has a number of metering inputs (such as M-Bus). Nodes are also equipped with digital outputs that allow switching off and on electrical/heat/gas/water supply for a particular consumer, upon commands from the utility company. Features DLC Communication Frequency Range 9 to 500 kHz Bandwidth 4 to 400 kHz freely configurable Carrier frequencies freely adjustable Bandwidth efficiency 0.5 to 2.9 bit/Hz/s Data rates 9.6 to 576 (288 CENELEC) kbps Transmission with OFDM and FEC synchronous and asynchronous transmission
mode complies with Standards EN 50065 (CENELEC), IEC
61000-3, FCC part 15 subpart B
Interfaces
1x Ethernet 10BaseT/100BaseTX electrical or 100BaseFX optical variant.
2x RS232/RS485, mode selectable by software control
CAN-Bus, fully compliant with the ISO 11898 standard, high speed and low speed mode
3 x EN 62056 (IEC1107) metering interface (optional)
M-Bus Master metering interface (optional) Smartcard Reader for standard SIM-cards
compliant to ISO 7816 standard (optional) System connector (for connecting e.g. I/O
card)
Communication Architecture
DLC-2000 Intranet
Driver 3
S0 Meter
DLC-200 Communication Interface
Driver 2 Protocol Translator Driver 1
Driver 2 Driver 1
Access Point services for drivers
Data transmission over PLC
Alarm transmission over PLC
Powerline Adaptation Layer Powerline Communication System
Access Point
Node
S0 Meter
AccessPoint
Application
PowerlineComm.System
NodeApplication
Driver 3
Access Point services for protocols
IEC 1107Meter
IEC 101 Device
Powerline Communication System Powerline Adaptation Layer
DLC-200 Communication Interface
Content is subject to change without prior notice. DLC, DLC-1 and DLC-2000 are registered trademarks of iAd GmbH. Other brand, product or company names are property of the respective holder. Warranties, implied or expressed as well as liabilities for any damage resulting from using provided information in this document are excluded until part of a separate written contract.