Transcript
  • 8/17/2019 Dpk Coventional Clarifier

    1/5

    Water TreatmentPackage Plant Design

    Sedimentation TankDesign

    1 of 5

    Sedimentation Tank design

    Typical design criteria for horizontal-flow rectangular tanks with tube settlers

    MWH pp.823

    "Tube settlers typically have detention time less than 20min, but they still have a settling efficientycomparable to that of a rectangular settling tank with a minimum 2h detention time."

  • 8/17/2019 Dpk Coventional Clarifier

    2/5

    Water TreatmentPackage Plant Design

    Sedimentation TankDesign

    2 of 5

    General Data

    Raw water, Q = MLDRaw water, Q = m3/s

    Number of basin = No.

    Unit Load = m3/s= MLD

    Tube settlers

    Length Lp = mWidth d = m

    Settling Velocity, Vs = m/s AssumedƟ = 60 degrees

    Adopted Parameters

    Settling Zone Dimension by trial and error

    Width W = m AssumedDepth D = m AssumedLength L = m Assumed

    Settling Area, = m2Vf Ɵ = m/sVf Ɵ = m/h < 2.5 to 6.25 m/h

    Total TankWidth W = mDepth D = mTotal Length L = m

    Tank volume, V = m3 including additional % for settling.Thus, Total length = m

    Detention time, T = s= 79 min ( 6 to 10 min.) OK

    2.5

    0.625

    11.50.00206

    0.00061

    0.05

    2.32.4

    6.25

    6.25

    0.0289

    4

    2.31

    0.9

    0.00723

    34.5

    5

    4769

    25

    7.42918

  • 8/17/2019 Dpk Coventional Clarifier

    3/5

    Water TreatmentPackage Plant Design

    Sedimentation TankDesign

    3 of 5

    MWH, pp.810

    Design Calculations

    Settling Velocity, Vs = m/s Assumed

    Countercurrent Settlers

    = s

    = s

    Reynolds Number < 20,000

    =

    Froude Number > 0.00001

    =vf = m/sAx = m2Pw = mv = m2/sg = m/s2Rh = m

    1E-067.1

    85.906

    479.39

    0.0006

    1598

    5.58E-070.0021

    5.52

    9.810.7775

  • 8/17/2019 Dpk Coventional Clarifier

    4/5

    Water TreatmentPackage Plant Design

    Sedimentation TankDesign

    4 of 5

    Water Treatment Unit Processes: Physical and Chemical pp.590By David W. Hendricks

    Submerged Trough Design

    Trough Design

    Input Load = m3/s (includes both clarifier discharge)

    Wash down loss = % Assumed

    Est. Trough load = m3/s or MLDMax. over flow Rate, vf = m/s

    Area Req. , Ax = m2

    Trough width = mwater depth = mFree board = mTrough heigth = m

    2.375

    11.3

    13.3

    0.0021

    1.211.10.2

    0.0289

    5

    0.0275

  • 8/17/2019 Dpk Coventional Clarifier

    5/5


Top Related