SHEET TITLE
DWG NO.
SCALE
DATE
NOT TO SCALE
Disclaimer: Ardex makes every reasonable effort to ensure that the technical details, recommendations and other information contained in this drawing are accurate and represent our knowledge and experience at the time of design and
publication. Ardex reserves the right to change the information without prior notice. Ardex provides the information in good faith with no representations or warranties (whether implied or otherwise), and will not be liable for any losses or
damages (whether direct, indirect or consequential) whatsoever, whether in contract, negligence or any other action, arising out of or in connection with the use, or inability to use, the information.
It is your responsibility to ensure that our products are used only for the purposes for which they are intended and are used in accordance with any applicable specifications, guidelines, standards, codes of practice, regulations and laws.
The supply of our products and services are also subject to certain terms, warranties and exclusions which are available on request.
ARDEX BUTYNOL DRAWING LISTAB-0005/04/2019
ARDEX BUTYNOL DRAWING LIST
DRAWING NO. SHEET TITLE DATE
AB-00 DRAWING LIST 05/04/2019
AB-01 THRESHOLD AT OPENING - REBATED 05/04/2019
AB-02 THRESHOLD AT OPENING 05/04/2019
AB-03 BOTTOM PLATE WALL - DIRECT FIXED 05/04/2019
AB-04 BOTTOM PLATE WALL - CAVITY 05/04/2019
AB-05 INTERNAL CENTRAL 05/04/2019
AB-06 INTERNAL GUTTER 05/04/2019
AB-07 BOX GUTTER & PARAPET DOWNTURN 05/04/2019
AB-08 OVERFLOW 05/04/2019
AB-09 SCUPPER OUTLET 05/04/2019
AB-10 EAVES & VERGE 05/04/2019
AB-11 SPOUTING 05/04/2019
AB-12 ROOF PENETRATION 05/04/2019
AB-13 FLASHING INTO CONCRETE WALLS - CHASE 05/04/2019
AB-14 FLASHING INTO CONCRETE WALLS - MECHANICAL 05/04/2019
AB-15 FLASHING INTO CONCRETE WALLS - FLASHING 05/04/2019
AB-16 ONE WAY SUBSTRATE VENTILATOR 05/04/2019
AB-17 PIPE PENETRATION 05/04/2019
AB-18 TOP FIXED BALUSTRADE 05/04/2019
AB-19 PLANT EQUIPMENT SUPPORTS 05/04/2019
AB-20 TAPING SUBSTRATE 05/04/2019
AB-21 SEISMIC JOINT 05/04/2019
AB-22 CONSTRUCTION JOINT 05/04/2019
AB-23 TYPICAL MEMBRANE LAP & LAYERS 05/04/2019
AB-24 3D - INTERNAL CORNER 05/04/2019
AB-25 3D - INTERNAL ROOF DRAIN 05/04/2019
AB-26 3D - RAINWATER HEAD & SCUPPER OPENING IN MEMBRANE 05/04/2019
AB-27 3D - ROOF EDGE MECHANICAL FIXED 05/04/2019
AB-28 WARM ROOF SYSTEM - CONCRETE 05/04/2019
AB-29 WARM ROOF SYSTEM - METAL DECK 05/04/2019
AB-30 WARM ROOF SYSTEM - PLYWOOD 05/04/2019
FLOOR STRUCTURE
ENCLOSED DECK STRUCTURE
FINISHED FLOOR LEVEL
SILL FLASHING WITH 5º SLOPE ANDSTOPENDS
DRESS BUTYNOL 100mm MIN.UP FRAMING AT ENDS. WIDTH TO
SUIT JOINERY AND CLADDING
WALL OFFSET TODECK STRUCTURE
FLOOR DEPTH100 M
IN.
ARDEX CA20P
SHEET TITLE
DWG NO.
SCALE @ A4
DATEDisclaimer: Ardex makes every reasonable effort to ensure that the technical details, recommendations and other information contained in this drawing are accurate and represent our knowledge and experience at the time of design and
publication. Ardex reserves the right to change the information without prior notice. Ardex provides the information in good faith with no representations or warranties (whether implied or otherwise), and will not be liable for any losses or
damages (whether direct, indirect or consequential) whatsoever, whether in contract, negligence or any other action, arising out of or in connection with the use, or inability to use, the information.
It is your responsibility to ensure that our products are used only for the purposes for which they are intended and are used in accordance with any applicable specifications, guidelines, standards, codes of practice, regulations and laws.
The supply of our products and services are also subject to certain terms, warranties and exclusions which are available on request. 1 : 2
ARDEX BUTYNOL THRESHOLD AT OPENING - REBATEDAB-0105/04/2019
FLOOR STRUCTURE
ENCLOSED DECK STRUCTURE
FINISHED FLOOR LEVEL
100 M
IN.
SILL FLASHING WITH 5º SLOPE ANDSTOPENDS
DRESS BUTYNOL 100mm MIN.UP FRAMING AT ENDS. WIDTH TO
SUIT JOINERY AND CLADDING
WALL OFFSET TODECK STRUCTURE
ARDEX CA20P
SHEET TITLE
DWG NO.
SCALE @ A4
DATEDisclaimer: Ardex makes every reasonable effort to ensure that the technical details, recommendations and other information contained in this drawing are accurate and represent our knowledge and experience at the time of design and
publication. Ardex reserves the right to change the information without prior notice. Ardex provides the information in good faith with no representations or warranties (whether implied or otherwise), and will not be liable for any losses or
damages (whether direct, indirect or consequential) whatsoever, whether in contract, negligence or any other action, arising out of or in connection with the use, or inability to use, the information.
It is your responsibility to ensure that our products are used only for the purposes for which they are intended and are used in accordance with any applicable specifications, guidelines, standards, codes of practice, regulations and laws.
The supply of our products and services are also subject to certain terms, warranties and exclusions which are available on request. 1 : 2
ARDEX BUTYNOL THRESHOLD AT OPENINGAB-0205/04/2019
FLOOR STRUCTURE
ENCLOSED DECK STRUCTURE
150 M
IN.
100 M
IN.
CARRY BUTYNOL UP BEHIND WRAPAND PAST THE BOTTOM PLATE OF
THE WALL FRAMING
FINISHED FLOOR LEVEL
BUILDING WRAP
6
WALL OFFSET TO DECK STRUCTURE
35 M
IN.
CLADDING
SHEET TITLE
DWG NO.
SCALE @ A4
DATEDisclaimer: Ardex makes every reasonable effort to ensure that the technical details, recommendations and other information contained in this drawing are accurate and represent our knowledge and experience at the time of design and
publication. Ardex reserves the right to change the information without prior notice. Ardex provides the information in good faith with no representations or warranties (whether implied or otherwise), and will not be liable for any losses or
damages (whether direct, indirect or consequential) whatsoever, whether in contract, negligence or any other action, arising out of or in connection with the use, or inability to use, the information.
It is your responsibility to ensure that our products are used only for the purposes for which they are intended and are used in accordance with any applicable specifications, guidelines, standards, codes of practice, regulations and laws.
The supply of our products and services are also subject to certain terms, warranties and exclusions which are available on request. 1 : 2
ARDEX BUTYNOL BOTTOM PLATE WALL - DIRECT FIXEDAB-0305/04/2019
FLOOR STRUCTURE
ENCLOSED DECK STRUCTURE
150 M
IN.
100 M
IN.
FINISHED FLOOR LEVEL
CARRY BUTYNOL UP BEHIND WRAPAND PAST THE BOTTOM PLATE OF
THE WALL FRAMING
CAVITY BASE CLOSURE
DRIP EDGE
NOTE:1). INTERNAL CORNERS TO BE FORMED AS PER DETAIL
2). DIMENSIONS ARE SHOWN TO BUTYNOL. HOWEVER,
WHERE THERE IS ADDITIONAL MATERIAL APPLIED OVER
THE BUTYNOL ALL DIMENSIONS SHALL APPLY TO THE
HIGHEST LEVEL OF THE WEARING SURFACE
35 M
IN.
CLADDING
CAVITY
SHEET TITLE
DWG NO.
SCALE @ A4
DATEDisclaimer: Ardex makes every reasonable effort to ensure that the technical details, recommendations and other information contained in this drawing are accurate and represent our knowledge and experience at the time of design and
publication. Ardex reserves the right to change the information without prior notice. Ardex provides the information in good faith with no representations or warranties (whether implied or otherwise), and will not be liable for any losses or
damages (whether direct, indirect or consequential) whatsoever, whether in contract, negligence or any other action, arising out of or in connection with the use, or inability to use, the information.
It is your responsibility to ensure that our products are used only for the purposes for which they are intended and are used in accordance with any applicable specifications, guidelines, standards, codes of practice, regulations and laws.
The supply of our products and services are also subject to certain terms, warranties and exclusions which are available on request. 1 : 2
ARDEX BUTYNOL BOTTOM PLATE WALL - CAVITYAB-0405/04/2019
ARDEX BUTYNOL ADHERED WITHARDEX WA98
ARDEX SS CLAMPED LEAF GUARD
GUTTER FALL 1:100
FALLFALL
FILLET
GUTTER WIDTH IN ACCORDANCE WITH NZBC E2/AS1
300 MIN.
SHEET TITLE
DWG NO.
SCALE @ A4
DATEDisclaimer: Ardex makes every reasonable effort to ensure that the technical details, recommendations and other information contained in this drawing are accurate and represent our knowledge and experience at the time of design and
publication. Ardex reserves the right to change the information without prior notice. Ardex provides the information in good faith with no representations or warranties (whether implied or otherwise), and will not be liable for any losses or
damages (whether direct, indirect or consequential) whatsoever, whether in contract, negligence or any other action, arising out of or in connection with the use, or inability to use, the information.
It is your responsibility to ensure that our products are used only for the purposes for which they are intended and are used in accordance with any applicable specifications, guidelines, standards, codes of practice, regulations and laws.
The supply of our products and services are also subject to certain terms, warranties and exclusions which are available on request. 1 : 2
ARDEX BUTYNOL INTERNAL CENTRALAB-0505/04/2019
ARDEX BUTYNOL ADHERED WITHARDEX WA98
GUTTER SIZE & FALL INACCORDANCE WITH NZBC E2/AS1
300MIN.
FILLET
PLYWOOD SUBSTRATE TO COMPLYWITH CURRENT ARDEX BUTYNOL
MASTERSPEC SPECIFICATION
GUTTER WIDTH IN ACCORDANCE WITH NZBC E2/AS1
300 MIN.
50 MIN. 50 MIN.
METAL ROOFING
SHEET TITLE
DWG NO.
SCALE @ A4
DATEDisclaimer: Ardex makes every reasonable effort to ensure that the technical details, recommendations and other information contained in this drawing are accurate and represent our knowledge and experience at the time of design and
publication. Ardex reserves the right to change the information without prior notice. Ardex provides the information in good faith with no representations or warranties (whether implied or otherwise), and will not be liable for any losses or
damages (whether direct, indirect or consequential) whatsoever, whether in contract, negligence or any other action, arising out of or in connection with the use, or inability to use, the information.
It is your responsibility to ensure that our products are used only for the purposes for which they are intended and are used in accordance with any applicable specifications, guidelines, standards, codes of practice, regulations and laws.
The supply of our products and services are also subject to certain terms, warranties and exclusions which are available on request. 1 : 2
ARDEX BUTYNOL INTERNAL GUTTERAB-0605/04/2019
FILLET
METAL CAPPING
MIN. 5.0°
FILLET
ARDEX BUTYNOL ADHERED WITHARDEX WA98
GUTTER SIZE & FALL INACCORDANCE WITH NZBC E2/AS1
300MIN.
PLYWOOD
PLYWOOD SUBSTRATE TO COMPLYWITH CURRENT ARDEX BUTYNOL
MASTERSPEC SPECIFICATION
ROOF CLADDING
50 MIN.
GUTTER WIDTH IN ACCORDANCE WITH NZBC E2/AS1
300 MIN.
WIT
H N
ZB
C E
2/A
S1
IN A
CC
OR
DA
NC
E
WIT
H N
ZB
C E
2/A
S1
IN A
CC
OR
DA
NC
E
SHEET TITLE
DWG NO.
SCALE @ A4
DATEDisclaimer: Ardex makes every reasonable effort to ensure that the technical details, recommendations and other information contained in this drawing are accurate and represent our knowledge and experience at the time of design and
publication. Ardex reserves the right to change the information without prior notice. Ardex provides the information in good faith with no representations or warranties (whether implied or otherwise), and will not be liable for any losses or
damages (whether direct, indirect or consequential) whatsoever, whether in contract, negligence or any other action, arising out of or in connection with the use, or inability to use, the information.
It is your responsibility to ensure that our products are used only for the purposes for which they are intended and are used in accordance with any applicable specifications, guidelines, standards, codes of practice, regulations and laws.
The supply of our products and services are also subject to certain terms, warranties and exclusions which are available on request. 1 : 2
ARDEX BUTYNOL BOX GUTTER & PARAPET DOWNTURNAB-0705/04/2019
ARDEX SCUPPER
ARDEX CA20P
TAPE
CAVITY CLOSER
ARDEX BUTYNOL ADHERED WITHARDEX WA98
ARDEX SEAM TAPE/SEAM PRIMER
ARDEX SEAM TAPE/SEAM PRIMER
50 MIN. PLYWOOD SUBSTRATE TO COMPLYWITH CURRENT ARDEX BUTYNOL
MASTERSPEC SPECIFICATION
CLADDING
SHEET TITLE
DWG NO.
SCALE @ A4
DATEDisclaimer: Ardex makes every reasonable effort to ensure that the technical details, recommendations and other information contained in this drawing are accurate and represent our knowledge and experience at the time of design and
publication. Ardex reserves the right to change the information without prior notice. Ardex provides the information in good faith with no representations or warranties (whether implied or otherwise), and will not be liable for any losses or
damages (whether direct, indirect or consequential) whatsoever, whether in contract, negligence or any other action, arising out of or in connection with the use, or inability to use, the information.
It is your responsibility to ensure that our products are used only for the purposes for which they are intended and are used in accordance with any applicable specifications, guidelines, standards, codes of practice, regulations and laws.
The supply of our products and services are also subject to certain terms, warranties and exclusions which are available on request. 1 : 2
ARDEX BUTYNOL OVERFLOWAB-0805/04/2019
ARDEX SCUPPER
ARDEX BUTYNOL ADHERED WITHARDEX WA98
MIN.5.0°
METAL CAPPING
ARDEX SEAM TAPE/SEAM PRIMER
ARDEX SEAM TAPE/SEAM PRIMER
ARDEX CA20P
50 MIN.
EXTERNAL RAINHEAD WITHOVERFLOW
ARDEX BUTYNOL ADHERED WITHARDEX WA98
PLYWOOD SUBSTRATE TO COMPLYWITH CURRENT ARDEX BUTYNOL
MASTERSPEC SPECIFICATION
WIT
H N
ZB
C E
2/A
S1
IN A
CC
OR
DA
NC
E
WIT
H N
ZB
C E
2/A
S1
IN A
CC
OR
DA
NC
E
SHEET TITLE
DWG NO.
SCALE @ A4
DATEDisclaimer: Ardex makes every reasonable effort to ensure that the technical details, recommendations and other information contained in this drawing are accurate and represent our knowledge and experience at the time of design and
publication. Ardex reserves the right to change the information without prior notice. Ardex provides the information in good faith with no representations or warranties (whether implied or otherwise), and will not be liable for any losses or
damages (whether direct, indirect or consequential) whatsoever, whether in contract, negligence or any other action, arising out of or in connection with the use, or inability to use, the information.
It is your responsibility to ensure that our products are used only for the purposes for which they are intended and are used in accordance with any applicable specifications, guidelines, standards, codes of practice, regulations and laws.
The supply of our products and services are also subject to certain terms, warranties and exclusions which are available on request. 1 : 2
ARDEX BUTYNOL SCUPPER OUTLETAB-0905/04/2019
WIT
H N
ZB
C N
ZB
C E
2/A
S1
IN A
CC
OR
DA
NC
E
ARDEX BUTYNOL ADHERED WITHARDEX WA98
BARGE BOARD
BUILDING WRAP
MEMBRANE DRESSED DOWN OVERBARGE FLASHING AND RETURNED AT
ENDS
PLYWOOD
APPROPRIATE FASTENER
ARDEX PRESSURE SEAL WITH ARDEXCA20P SEALANT
CLADDING
UPSTAND FRAMING
SHEET TITLE
DWG NO.
SCALE @ A4
DATEDisclaimer: Ardex makes every reasonable effort to ensure that the technical details, recommendations and other information contained in this drawing are accurate and represent our knowledge and experience at the time of design and
publication. Ardex reserves the right to change the information without prior notice. Ardex provides the information in good faith with no representations or warranties (whether implied or otherwise), and will not be liable for any losses or
damages (whether direct, indirect or consequential) whatsoever, whether in contract, negligence or any other action, arising out of or in connection with the use, or inability to use, the information.
It is your responsibility to ensure that our products are used only for the purposes for which they are intended and are used in accordance with any applicable specifications, guidelines, standards, codes of practice, regulations and laws.
The supply of our products and services are also subject to certain terms, warranties and exclusions which are available on request. 1 : 2
ARDEX BUTYNOL EAVES & VERGEAB-1005/04/2019
SPOUTING BY OTHERS
ARDEX BUTYNOL ADHERED WITHARDEX WA98
PLYWOOD SUBSTRATE TO COMPLYWITH CURRENT ARDEX BUTYNOL
MASTERSPEC SPECIFICATION
FASCIA
STAINLESS STEEL FIXING
PVC TAPE SEPARATION LAYER
ALUMINIUM ANGLE
50 MIN.
SHEET TITLE
DWG NO.
SCALE @ A4
DATEDisclaimer: Ardex makes every reasonable effort to ensure that the technical details, recommendations and other information contained in this drawing are accurate and represent our knowledge and experience at the time of design and
publication. Ardex reserves the right to change the information without prior notice. Ardex provides the information in good faith with no representations or warranties (whether implied or otherwise), and will not be liable for any losses or
damages (whether direct, indirect or consequential) whatsoever, whether in contract, negligence or any other action, arising out of or in connection with the use, or inability to use, the information.
It is your responsibility to ensure that our products are used only for the purposes for which they are intended and are used in accordance with any applicable specifications, guidelines, standards, codes of practice, regulations and laws.
The supply of our products and services are also subject to certain terms, warranties and exclusions which are available on request. 1 : 2
ARDEX BUTYNOL SPOUTINGAB-1105/04/2019
FILLET
ARDEX BUTYNOL ADHERED WITHARDEX WA98
OVER FLASHING FROM ROOFLIGHT,VENT ETC
NOTE:1). FOR MAX PENETRATION SIZE 1200x1200mm
2). EXTERNAL CORNERS TO BE FORMED AS SHOWN
IN A
CC
OR
DA
NC
E W
ITH
NZ
BC
E2/A
S1
150 M
IN.
PLYWOOD
INTERNAL LINING
SHEET TITLE
DWG NO.
SCALE @ A4
DATEDisclaimer: Ardex makes every reasonable effort to ensure that the technical details, recommendations and other information contained in this drawing are accurate and represent our knowledge and experience at the time of design and
publication. Ardex reserves the right to change the information without prior notice. Ardex provides the information in good faith with no representations or warranties (whether implied or otherwise), and will not be liable for any losses or
damages (whether direct, indirect or consequential) whatsoever, whether in contract, negligence or any other action, arising out of or in connection with the use, or inability to use, the information.
It is your responsibility to ensure that our products are used only for the purposes for which they are intended and are used in accordance with any applicable specifications, guidelines, standards, codes of practice, regulations and laws.
The supply of our products and services are also subject to certain terms, warranties and exclusions which are available on request. 1 : 2
ARDEX BUTYNOL ROOF PENETRATIONAB-1205/04/2019
CONCRETE
ARDEX BUTYNOL ADHERED WITHARDEX WA98
FILLET
NOTE:ARDEX BUTYNOL IS ADHERED WITH ARDEX WA98
ADHESIVE INTO SQUARE CHASE AND FINISHED WITH
ARDEX CA20P SEALANT
ARDEX CA20P
SQUARE CHASE
RADIUS ANGLE
150 M
IN.
15 - 20 mm
SHEET TITLE
DWG NO.
SCALE @ A4
DATEDisclaimer: Ardex makes every reasonable effort to ensure that the technical details, recommendations and other information contained in this drawing are accurate and represent our knowledge and experience at the time of design and
publication. Ardex reserves the right to change the information without prior notice. Ardex provides the information in good faith with no representations or warranties (whether implied or otherwise), and will not be liable for any losses or
damages (whether direct, indirect or consequential) whatsoever, whether in contract, negligence or any other action, arising out of or in connection with the use, or inability to use, the information.
It is your responsibility to ensure that our products are used only for the purposes for which they are intended and are used in accordance with any applicable specifications, guidelines, standards, codes of practice, regulations and laws.
The supply of our products and services are also subject to certain terms, warranties and exclusions which are available on request. 1 : 2
ARDEX BUTYNOL FLASHING INTO CONCRETE WALLS - CHASEAB-1305/04/2019
CONCRETE
ARDEX BUTYNOL ADHERED WITHARDEX WA98
FILLET
ARDEX PRESSURE SEAL WITH ARDEXCA20P SEALANT
APPROPRIATE FASTENER
150 M
IN.
SHEET TITLE
DWG NO.
SCALE @ A4
DATEDisclaimer: Ardex makes every reasonable effort to ensure that the technical details, recommendations and other information contained in this drawing are accurate and represent our knowledge and experience at the time of design and
publication. Ardex reserves the right to change the information without prior notice. Ardex provides the information in good faith with no representations or warranties (whether implied or otherwise), and will not be liable for any losses or
damages (whether direct, indirect or consequential) whatsoever, whether in contract, negligence or any other action, arising out of or in connection with the use, or inability to use, the information.
It is your responsibility to ensure that our products are used only for the purposes for which they are intended and are used in accordance with any applicable specifications, guidelines, standards, codes of practice, regulations and laws.
The supply of our products and services are also subject to certain terms, warranties and exclusions which are available on request. 1 : 2
ARDEX BUTYNOL FLASHING INTO CONCRETE WALLS - MECHANICALAB-1405/04/2019
ARDEX BUTYNOL ADHERED WITHARDEX WA98
ARDEX LO RISE VENT INSTALLEDOVER INTERSECTION OF VENT TAPES
ON PLYWOOD SUBSTRATE
CAVIBAT BATTEN
PLYWOOD SUBSTRATE TO COMPLYWITH CURRENT ARDEX BUTYNOL
MASTERSPEC SPECIFICATION
3 GAP
CEILING INSULATION
SHEET TITLE
DWG NO.
SCALE @ A4
DATEDisclaimer: Ardex makes every reasonable effort to ensure that the technical details, recommendations and other information contained in this drawing are accurate and represent our knowledge and experience at the time of design and
publication. Ardex reserves the right to change the information without prior notice. Ardex provides the information in good faith with no representations or warranties (whether implied or otherwise), and will not be liable for any losses or
damages (whether direct, indirect or consequential) whatsoever, whether in contract, negligence or any other action, arising out of or in connection with the use, or inability to use, the information.
It is your responsibility to ensure that our products are used only for the purposes for which they are intended and are used in accordance with any applicable specifications, guidelines, standards, codes of practice, regulations and laws.
The supply of our products and services are also subject to certain terms, warranties and exclusions which are available on request. 1 : 2
ARDEX BUTYNOL ONE WAY SUBSTRATE VENTILATORAB-1605/04/2019
STAINLESS STEEL CLIP
ARDEX BUTYNOL ADHERED WITHARDEX WA98
PLYWOOD
NOTE:IF FLASHING TAPE IS USED IT MUST NOT BE LEFT
EXPOSED. A COVER STRIP BUTYNOL MUST BE
APPLIED OVER THE FLASHING TAPE TO FINISH
FLASHING TAPE
ARDEX BUTYNOL COVER STRIP
SHEET TITLE
DWG NO.
SCALE @ A4
DATEDisclaimer: Ardex makes every reasonable effort to ensure that the technical details, recommendations and other information contained in this drawing are accurate and represent our knowledge and experience at the time of design and
publication. Ardex reserves the right to change the information without prior notice. Ardex provides the information in good faith with no representations or warranties (whether implied or otherwise), and will not be liable for any losses or
damages (whether direct, indirect or consequential) whatsoever, whether in contract, negligence or any other action, arising out of or in connection with the use, or inability to use, the information.
It is your responsibility to ensure that our products are used only for the purposes for which they are intended and are used in accordance with any applicable specifications, guidelines, standards, codes of practice, regulations and laws.
The supply of our products and services are also subject to certain terms, warranties and exclusions which are available on request. 1 : 2
ARDEX BUTYNOL PIPE PENETRATIONAB-1705/04/2019
ARDEX BUTYNOL ADHERED WITHARDEX WA98
PLYWOOD
DETAIL TAPE
PLINTH
SCREWED TOP PLATE
SHEET TITLE
DWG NO.
SCALE @ A4
DATEDisclaimer: Ardex makes every reasonable effort to ensure that the technical details, recommendations and other information contained in this drawing are accurate and represent our knowledge and experience at the time of design and
publication. Ardex reserves the right to change the information without prior notice. Ardex provides the information in good faith with no representations or warranties (whether implied or otherwise), and will not be liable for any losses or
damages (whether direct, indirect or consequential) whatsoever, whether in contract, negligence or any other action, arising out of or in connection with the use, or inability to use, the information.
It is your responsibility to ensure that our products are used only for the purposes for which they are intended and are used in accordance with any applicable specifications, guidelines, standards, codes of practice, regulations and laws.
The supply of our products and services are also subject to certain terms, warranties and exclusions which are available on request. 1 : 2
ARDEX BUTYNOL PLANT EQUIPMENT SUPPORTSAB-1905/04/2019
ARDEX BUTYNOL ADHERED WITHARDEX WA98
ARDEX RELEASE TAPE
NOTE:ALL JOINTS BETWEEN SUBSTRATE SHEETS OF
PLYWOOD SHOULD BE TAPED TO PREVENT
STRESSING OF THE ARDEX BUTYNOL IN CASE
OF MARKED TIMBER MOVEMENT
PLYWOOD SUBSTRATE TO COMPLYWITH CURRENT ARDEX BUTYNOL
MASTERSPEC SPECIFICATION
3 GAP
SHEET TITLE
DWG NO.
SCALE @ A4
DATEDisclaimer: Ardex makes every reasonable effort to ensure that the technical details, recommendations and other information contained in this drawing are accurate and represent our knowledge and experience at the time of design and
publication. Ardex reserves the right to change the information without prior notice. Ardex provides the information in good faith with no representations or warranties (whether implied or otherwise), and will not be liable for any losses or
damages (whether direct, indirect or consequential) whatsoever, whether in contract, negligence or any other action, arising out of or in connection with the use, or inability to use, the information.
It is your responsibility to ensure that our products are used only for the purposes for which they are intended and are used in accordance with any applicable specifications, guidelines, standards, codes of practice, regulations and laws.
The supply of our products and services are also subject to certain terms, warranties and exclusions which are available on request. 1 : 2
ARDEX BUTYNOL TAPING SUBSTRATEAB-2005/04/2019
ARDEX BUTYNOL ADHERED WITHARDEX WA98
EXPANSION JOINT
FIRE RESISTANT PRODUCT AS PERFIRE ENGINEERS REQUIREMENTS
BUTYNOL UNDERFLASHING FULLYBONDED TO ONE SIDE OF JOINT
CONCRETE SLAB
SHEET TITLE
DWG NO.
SCALE @ A4
DATEDisclaimer: Ardex makes every reasonable effort to ensure that the technical details, recommendations and other information contained in this drawing are accurate and represent our knowledge and experience at the time of design and
publication. Ardex reserves the right to change the information without prior notice. Ardex provides the information in good faith with no representations or warranties (whether implied or otherwise), and will not be liable for any losses or
damages (whether direct, indirect or consequential) whatsoever, whether in contract, negligence or any other action, arising out of or in connection with the use, or inability to use, the information.
It is your responsibility to ensure that our products are used only for the purposes for which they are intended and are used in accordance with any applicable specifications, guidelines, standards, codes of practice, regulations and laws.
The supply of our products and services are also subject to certain terms, warranties and exclusions which are available on request. 1 : 2
ARDEX BUTYNOL SEISMIC JOINTAB-2105/04/2019
ARDEX BUTYNOL ADHERED WITHARDEX WA98
EXPANSION JOINT
ADHESIVE STUCK TO ONE SIDE OFTHE JOINT ONLY
CONCRETE SLAB
SHEET TITLE
DWG NO.
SCALE @ A4
DATEDisclaimer: Ardex makes every reasonable effort to ensure that the technical details, recommendations and other information contained in this drawing are accurate and represent our knowledge and experience at the time of design and
publication. Ardex reserves the right to change the information without prior notice. Ardex provides the information in good faith with no representations or warranties (whether implied or otherwise), and will not be liable for any losses or
damages (whether direct, indirect or consequential) whatsoever, whether in contract, negligence or any other action, arising out of or in connection with the use, or inability to use, the information.
It is your responsibility to ensure that our products are used only for the purposes for which they are intended and are used in accordance with any applicable specifications, guidelines, standards, codes of practice, regulations and laws.
The supply of our products and services are also subject to certain terms, warranties and exclusions which are available on request. 1 : 2
ARDEX BUTYNOL CONSTRUCTION JOINTAB-2205/04/2019
50ARDEX BUTYNOL ADHERED WITHARDEX WA98
ARDEX SEAM TAPE AND SEAMPRIMER
SELECTED SUBSTRATE
SHEET TITLE
DWG NO.
SCALE @ A4
DATEDisclaimer: Ardex makes every reasonable effort to ensure that the technical details, recommendations and other information contained in this drawing are accurate and represent our knowledge and experience at the time of design and
publication. Ardex reserves the right to change the information without prior notice. Ardex provides the information in good faith with no representations or warranties (whether implied or otherwise), and will not be liable for any losses or
damages (whether direct, indirect or consequential) whatsoever, whether in contract, negligence or any other action, arising out of or in connection with the use, or inability to use, the information.
It is your responsibility to ensure that our products are used only for the purposes for which they are intended and are used in accordance with any applicable specifications, guidelines, standards, codes of practice, regulations and laws.
The supply of our products and services are also subject to certain terms, warranties and exclusions which are available on request. 1 : 2
ARDEX BUTYNOL TYPICAL MEMBRANE LAP & LAYERSAB-2305/04/2019
ARDEX BUTYNOL ADHERED WITH ARDEXWA98
SCREWS
BASE CONE FLANGE LINE OF SEAMTOP TO BE INSTALLED
GRATE COVER TO SUIT FINISHEDAPPLICATION
INNER CLAMP RING
APPLY ARDEX WA98 ADHESIVE TOSUBSTRATE BASE IN REQUIRED STAGES
SHEET TITLE
DWG NO.
SCALE
DATE
NOT TO SCALE
Disclaimer: Ardex makes every reasonable effort to ensure that the technical details, recommendations and other information contained in this drawing are accurate and represent our knowledge and experience at the time of design and
publication. Ardex reserves the right to change the information without prior notice. Ardex provides the information in good faith with no representations or warranties (whether implied or otherwise), and will not be liable for any losses or
damages (whether direct, indirect or consequential) whatsoever, whether in contract, negligence or any other action, arising out of or in connection with the use, or inability to use, the information.
It is your responsibility to ensure that our products are used only for the purposes for which they are intended and are used in accordance with any applicable specifications, guidelines, standards, codes of practice, regulations and laws.
The supply of our products and services are also subject to certain terms, warranties and exclusions which are available on request.
ARDEX BUTYNOL 3D - INTERNAL ROOF DRAINAB-2505/04/2019
75 M
IN.
OP
EN
ING
200 MIN.
OPENING
OPENING +
100 MIN
.
ARDEX EXTERNALRAINHEAD
DOWNPIPE
LIP OF DISCHARGE ATLOWEST POINT OF ROOF
SHEET TITLE
DWG NO.
SCALE
DATE
NOT TO SCALE
Disclaimer: Ardex makes every reasonable effort to ensure that the technical details, recommendations and other information contained in this drawing are accurate and represent our knowledge and experience at the time of design and
publication. Ardex reserves the right to change the information without prior notice. Ardex provides the information in good faith with no representations or warranties (whether implied or otherwise), and will not be liable for any losses or
damages (whether direct, indirect or consequential) whatsoever, whether in contract, negligence or any other action, arising out of or in connection with the use, or inability to use, the information.
It is your responsibility to ensure that our products are used only for the purposes for which they are intended and are used in accordance with any applicable specifications, guidelines, standards, codes of practice, regulations and laws.
The supply of our products and services are also subject to certain terms, warranties and exclusions which are available on request.
ARDEX BUTYNOL 3D - RAINWATER HEAD & SCUPPER OPENING IN MEMBRANEAB-2605/04/2019
METAL CAPPING
FILLET
SUBSTRATE
ARDEX BUTYNOL ADHERED WITHARDEX WA98 TO SUBSTRATE
SHEET TITLE
DWG NO.
SCALE
DATE
NOT TO SCALE
Disclaimer: Ardex makes every reasonable effort to ensure that the technical details, recommendations and other information contained in this drawing are accurate and represent our knowledge and experience at the time of design and
publication. Ardex reserves the right to change the information without prior notice. Ardex provides the information in good faith with no representations or warranties (whether implied or otherwise), and will not be liable for any losses or
damages (whether direct, indirect or consequential) whatsoever, whether in contract, negligence or any other action, arising out of or in connection with the use, or inability to use, the information.
It is your responsibility to ensure that our products are used only for the purposes for which they are intended and are used in accordance with any applicable specifications, guidelines, standards, codes of practice, regulations and laws.
The supply of our products and services are also subject to certain terms, warranties and exclusions which are available on request.
ARDEX BUTYNOL 3D - ROOF EDGE MECHANICAL FIXEDAB-2705/04/2019
ARDEX BUTYNOL ADHERED WITHARDEX WA98
OPTIONAL ARDEX HD COVER BOARD
ARDEX POLYISO BOARD
ARDEX A38 SCREED TO FALLS.
TWIN PACK POLYISO ADHESIVE
CONCRETE
NOTE: FOR FASTENING OR FIXING PATTERN DEPENDENT ON WIND ZONE/R VALUES.CONSULT WITH AN ARDEX REPRESENTATIVE
SHEET TITLE
DWG NO.
SCALE @ A4
DATEDisclaimer: Ardex makes every reasonable effort to ensure that the technical details, recommendations and other information contained in this drawing are accurate and represent our knowledge and experience at the time of design and
publication. Ardex reserves the right to change the information without prior notice. Ardex provides the information in good faith with no representations or warranties (whether implied or otherwise), and will not be liable for any losses or
damages (whether direct, indirect or consequential) whatsoever, whether in contract, negligence or any other action, arising out of or in connection with the use, or inability to use, the information.
It is your responsibility to ensure that our products are used only for the purposes for which they are intended and are used in accordance with any applicable specifications, guidelines, standards, codes of practice, regulations and laws.
The supply of our products and services are also subject to certain terms, warranties and exclusions which are available on request. 1 : 2
ARDEX BUTYNOL WARM ROOF SYSTEM - CONCRETEAB-2805/04/2019
ARDEX BUTYNOL ADHERED WITHARDEX WA98
OPTIONAL ARDEX HD COVER BOARD
ARDEX POLYISO BOARD
ARDEX VAPOUR BARRIER(IF REQUIRED)
APPROVED DIMOND ROOFING METALDECK PITCHED TO FALLS
NOTE: FOR FASTENING OR FIXING PATTERN DEPENDENT ON WIND ZONE/R VALUES.CONSULT WITH AN ARDEX REPRESENTATIVE
SHEET TITLE
DWG NO.
SCALE @ A4
DATEDisclaimer: Ardex makes every reasonable effort to ensure that the technical details, recommendations and other information contained in this drawing are accurate and represent our knowledge and experience at the time of design and
publication. Ardex reserves the right to change the information without prior notice. Ardex provides the information in good faith with no representations or warranties (whether implied or otherwise), and will not be liable for any losses or
damages (whether direct, indirect or consequential) whatsoever, whether in contract, negligence or any other action, arising out of or in connection with the use, or inability to use, the information.
It is your responsibility to ensure that our products are used only for the purposes for which they are intended and are used in accordance with any applicable specifications, guidelines, standards, codes of practice, regulations and laws.
The supply of our products and services are also subject to certain terms, warranties and exclusions which are available on request. 1 : 2
ARDEX BUTYNOL WARM ROOF SYSTEM - METAL DECKAB-2905/04/2019
ARDEX BUTYNOL ADHERED WITHARDEX WA98
OPTIONAL ARDEX HD COVER BOARD
ARDEX POLYISO BOARD
ARDEX VAPOUR BARRIER(IF REQUIRED)
PLYWOOD PITCHED TO FALLS
NOTE: FOR FASTENING OR FIXING PATTERN DEPENDENT ON WIND ZONE/R VALUES.CONSULT WITH AN ARDEX REPRESENTATIVE
SHEET TITLE
DWG NO.
SCALE @ A4
DATEDisclaimer: Ardex makes every reasonable effort to ensure that the technical details, recommendations and other information contained in this drawing are accurate and represent our knowledge and experience at the time of design and
publication. Ardex reserves the right to change the information without prior notice. Ardex provides the information in good faith with no representations or warranties (whether implied or otherwise), and will not be liable for any losses or
damages (whether direct, indirect or consequential) whatsoever, whether in contract, negligence or any other action, arising out of or in connection with the use, or inability to use, the information.
It is your responsibility to ensure that our products are used only for the purposes for which they are intended and are used in accordance with any applicable specifications, guidelines, standards, codes of practice, regulations and laws.
The supply of our products and services are also subject to certain terms, warranties and exclusions which are available on request. 1 : 2
ARDEX BUTYNOL WARM ROOF SYSTEM - PLYWOODAB-3005/04/2019