Download - Drum Pump Motors SP-280P Series - AIQSA
Insulation Class:....................................................................................................................F2
WARNING: Not suitable for pumping flammable or combustible liquids or use in a hazardous duty environment.
DATA-280P-05-17
PSI (BAR) FT (M)
GPM(LPM)
5 4
6
PSI (BAR) FT (M)
GPM(LPM)
13
2
Technical Specifications
Enclosure: ...........................................................................................Open Drip Proof (IP44)Available Voltage: .................................................................SP-280P & SP-280P-V : 110V
Horsepower (Watts):...............................................................................................1.1 (825)
Phase:.................................................................................................................................1Amps:.............................................................................................2.5 - 8 (varies by voltage)Frequency: .............................................................................................................50-60 Hz
Certification:.....................................................................................ETL (110V) or CE (220V)Housing Material:...................................................................Thermoplastic Polyester Resin
Power Cord Length:..........................................................................................16 ft. (4,8 m)
Power Cord Plug Type:..............................................NEMA 5-15-P (110V) or CEE 7/7 (220V)Noise Level:...............................................................................................................84 dBaLow Voltage Release:.........................................................SP-280P-2 & SP-280P-2-V : Yes
Thermal Overload:..........................................................................................................Yes
Variable Speed:.....................................SP-280P-V, SP-280P-2-V, & SP-280P-2-VNL : Yes
Drum Pump Motors | SP-280P Series
Weight:............................................................................................................10 lbs (4,5 kg)
.................................................SP-280P, SP-280P-V, SP-280P-2NL & SP-280P-2-VNL : No
...........................................................................SP-280P, SP-280P-2 & SP-280P-2NL : No
....................................SP-280P-2, SP-280P-2-V, SP-280P-2-NL & SP-280P-2-VNL : 220V
Note: Not recommended for use with the SP-700SR or 800SR Series pump.
Insulation Class:....................................................................................................................F2
WARNING: Not suitable for pumping flammable or combustible liquids or use in a hazardous duty environment.
DATA-ENC-05-17
PSI (BAR) FT (M)
GPM(LPM)
5 4
6
PSI (BAR) FT (M)
GPM(LPM)
13
2
Technical Specifications
Enclosure: ...........................................................................................................TEFC (IP54)Available Voltage: .....................................................................SP-ENC & SP-ENC-V : 110V
Horsepower (Watts):...............................................................................................1.1 (825)
Phase:.................................................................................................................................1Amps:.............................................................................................2.5 - 8 (varies by voltage)Frequency: .............................................................................................................50-60 Hz
Certification:.....................................................................................ETL (110V) or CE (220V)Housing Material:...................................................................................Anodized AluminumPower Cord Length:..........................................................................................16 ft. (4,8 m)
Power Cord Plug Type:..............................................NEMA 5-15-P (110V) or CEE 7/7 (220V)
Noise Level:...............................................................................................................88 dBa
Low Voltage Release:............................................................SP-ENC-2 & SP-ENC-2-V : Yes
Thermal Overload:..........................................................................................................Yes
Variable Speed:.........................................SP-ENC-V, SP-ENC-2-V, & SP-ENC-2-VNL : Yes
Drum Pump Motors | SP-ENC Series
Weight:............................................................................................................13 lbs (5,9 kg)
.......................................................SP-ENC, SP-ENC-V, SP-ENC-2NL & SP-ENC-2-VNL : No
...............................................................................SP-ENC, SP-ENC-2 & SP-ENC-2NL : No
............................................SP-ENC-2, SP-ENC-2-V, SP-ENC-2NL & SP-ENC-2-VNL : 220V
Certification:.........SP-410EX : CSA Class I, Div. I, Group D, Insulation Class B, Temp Code T3C
DATA-400-05-17
PSI (BAR) FT (M)
GPM(LPM)
5 4
6
PSI (BAR) FT (M)
GPM(LPM)
13
2
Technical Specifications
Enclosure: ............................................................................................Explosion Proof (IP54)
Available Voltage: .....................................................................................SP-410EX : 110V
Horsepower (Watts):............................................................................SP-410EX : 0.3 (230)
Phase:.................................................................................................................................1Amps:.............................................................................................2 - 2.6 (varies by voltage)
Frequency: .............................................................................................................50-60 Hz
...........................................................................................SP-420EX : Atex II 2G Ex d IIA T4
Housing Material:..........................................Aluminum (Inner Housing) / Nylon (Outer Shell)
Power Cord Length:..........................................................................................12 ft. (3,7 m)
Power Cord Plug:..............................................................................................Not Provided
Noise Level:...............................................................................................................80 dBa
Thermal Overload:............................................................................................................No
Variable Speed:................................................................................................................No
Drum Pump Motors | SP-400 Series
Weight:............................................................................................................17 lbs (7,7 kg)
II 2G Ex d IIA T4
WARNING: Pumping of flammables or combustible liquids can generate a static electric discharge, causing fire or explosion resulting in injury or death. Read and understand operating instructions before starting this unit. Follow all federal, state and local safety codes including NFPA 30 - NFPA77. Prior to connecting to air supply, install bond and ground wires and check continuity of each wire. A meter reading of one ohm or less is required for safe liquid transfer. Use only metallic drum, receiving vessel and metallic pump when pumping flammables. Air motors are not recognized under any current Underwriter’s Laboratory listing program. Consult a qualified engineer for suitability for use in a hazardous area or on flammables.
NOTE: Explosion proof motor regulations require that motors be returned to the manufacturer for repair.
.............................................................................................................SP-420EX : 0.8 (600)
...................................................................................................................SP-420EX : 220V
DATA-A1-05-17
PSI (BAR) FT (M)
GPM(LPM)
5 4
6
PSI (BAR) FT (M)
GPM(LPM)
13
2
Technical Specifications
Power Type: ...........................................................................................................Pneumatic
Horsepower (Watts):...............................................................................................0.5 (370)
Certification:.............................................................................................Atex II 2 G c IIB T4Housing Material:..................................................................................................Cast Steel
Noise Level:................................................................................................................78 dBa
Drum Pump Motors | SP-A1
Weight:............................................................................................................2.7 lbs (1,2 kg)
II 2 G c IIB T4
WARNING: Pumping of flammables or combustible liquids can generate a static electric discharge, causing fire or explosion resulting in injury or death. Read and understand operating instructions before starting this unit. Follow all federal, state and local safety codes including NFPA 30 - NFPA77. Prior to connecting to air supply, install bond and ground wires and check continuity of each wire. A meter reading of one ohm or less is required for safe liquid transfer. Use only metallic drum, receiving vessel and metallic pump when pumping flammables. Air motors are not recognized under any current Underwriter’s Laboratory listing program. Consult a qualified engineer for suitability for use in a hazardous area or on flammables.
Note: Not recommended for use with the SP-700SR or 800SR Series pump.
Air Consumption:.........................................................27 CFM (13 l/sec) @ 80 psi (5.51 bar)
Air Inlet / Exhaust Size:......................................................................1/8" npt(f) / 1/8" npt(f)
Lubrication Required:.............................................................................................Yes, Daily
Adapter Material:.........................................................................................................Nylon
DATA-A2-05-17
PSI (BAR) FT (M)
GPM(LPM)
5 4
6
PSI (BAR) FT (M)
GPM(LPM)
13
2
Technical Specifications
Power Type: ...........................................................................................................Pneumatic
Horsepower (Watts):.............................................................................................0.75 (560)
Trigger Lock:........................................................................................................SP-A2 : No
Housing / Adapter Material:..................................................................................Aluminum
Noise Level:................................................................................................................87 dBa
Drum Pump Motors | SP-A2 Series
Weight:............................................................................................................3.4 lbs (1.5 kg)
WARNING: Pumping of flammables or combustible liquids can generate a static electric discharge, causing fire or explosion resulting in injury or death. Read and understand operating instructions before starting this unit. Follow all federal, state and local safety codes including NFPA 30 - NFPA77. Prior to connecting to air supply, install bond and ground wires and check continuity of each wire. A meter reading of one ohm or less is required for safe liquid transfer. Use only metallic drum, receiving vessel and metallic pump when pumping flammables. Air motors are not recognized under any current Underwriter’s Laboratory listing program. Consult a qualified engineer for suitability for use in a hazardous area or on flammables.
Note: Not recommended for use with the SP-700SR or 800SR Series pump.
Air Consumption:......................................................28 CFM (13.2 l/sec) @ 100 psi (6,8 bar)
Air Inlet / Exhaust Size:......................................................................1/4" npt(f) / 3/8" npt(f)
Lubrication Required:.............................................................................................Yes, Daily
........................................................................................................................SP-A2TL : Yes