P i P e S y S t e m S
Suitable for buildingS and houSeS.
EleganceraingutterS
CONTENTS
Elegance -FEaTurES & advantageS
22 elegance raingutters
3 elegance advantage
aCCrEdiTaTiON& StandardS
6 6 Quality&Certification
7 Specifications&Standards
Elegance -Product detail
8 8 raingutter & fittings
11 rainwater Pipes
12 PalingSolventCement
iNSTallaTiON
6 16 InstallationGuidelines
24 ProjectReferences1abOuT uS
5 25 AboutPalingIndustries
25 AboutAliaxis2
FEaTurES• Anexclusivelayout,withinternalbracketsandoutlets
thatcanbeplacedanywherealongthelengthofthegutter,avoidingtheneedtobreaktherunninglengthforthedownpipe
• Superioroutlook
• CertifiedBSEN607andBSEN1462
adVaNTaGES• CorrosionandUVResistant
• DurableandLightweight
• HighFlowCapacitywith16,100mm2
• NoOverFlow
• Anti-DrippingSystemtoPreventLeak
• WeirOutlettoInduceHigherFlowrate
• Designedtoaccommodateextensivethermalmovement
aPPliCaTiONPalingRaingutterSystemsarerecommendedforbuildingapplications,andarespecificallydesignedforcontemporaryhousesandcondominiums.
raiNGuTTErSProduct range
Stylish designTheuniquedesignofthePaling’s
Elegance rainwater gutter
Systemisabletocomplementany
contemporarylifestyletodate.With
thisexclusivelayout,theinternal
bracketsandoutletscanbeplaced
anywherealongthelengthofthe
gutterwithouttheneedtobreakthe
runninglengthtoaccommodatethe
down-pipe.
AcomprehensiverangeofPaling’s
Eleganceandaccessoriesaremanufacturedtothesamehigh
standards.Paling’sElegance range is
designedtosuitwideapplicationand
withitsaestheticallysuperioroutlook,
mostbuildingscanbenefitfromit.
2
ElEGaNCE raiNGuTTErS /// FEaTurES adVaNTaGES
Performance CharacteristicsPVC-Uisacorrosionfreematerial.Itcanwithstandtoughweatherconditionsforanextensiveperiodoftime.ItisUVresistant
eventhoughexposedtodirectsunlight.Itisalsoextremelydurable,lightweightandeasy-to-install.
PVC-Uismaintenancefree.Itssmoothsurfacepreventsalgaeandfungusgrowth.Together,theseinnovativefeatures
improvethebuilding’soutlook,reduceassemblyandinstallationtime,reducepercentageoffailureandhelpsaveupa
considerableamountofmoney.
Asaresult,thissystemofferseasierandfasterassembly,adesignthatlastmuchlongerthananytypicalrainwatergutter
system.
EfficiencyPaling’sEleganceGutterProfilehasahighcapacitywithaneffectivecrosssectionalareaof16100mm2.Itpreventsover
flowandkeepsthehousecleananddry.
Theexpansionoutlethashighflowcapacityandantidrippingfeature.Norubbergasketandsolventcementisrequired.In
addition,advancedesignatjointspreventsleakage.
Paling’sElegancecomplieswiththeStandardBSEN607forgutterprofileandfittingsandStandardBSEN1462forthegutter
brackets.
EleganceRainwaterGutterSystem
3
FEaTurES adVaNTaGES /// ElEGaNCE raiNGuTTErS
4
Paling gutter Profile
MoreflexibilitywithP-Shapefrontreturn
Groovedprofiletoenablehorizontalmovement
afterlockingintointernalbracket
Highercapacity16100mm2
exPanSion outlet
Weirflow,drainingupto6L/Sto10L/S
Noleakingwithantidrippingbaffle
Suitableforroundandrectangular
ElEGaNCE raiNGuTTErS /// adVaNTaGES
5
Paling internal bracket
AllowinghorizontalmovementwithP.Shape
Canloadupto60kgeach
Aestheticallysuperioroutlook
Paling exPanSion joiner
Accommodatesthermalmovementfrom-10°cto+40°c
2in1(Joiner+expansion)
Doublerubbersealstopreventleakages
adVaNTaGES /// ElEGaNCE raiNGuTTErS
6
RAINWATERGUTTER
RAINWATERGUTTERFITTINGS
RAINWATERDOWNPIPES
1. UnplasticizedPolyvinylChloride(PVC-U)rainwater gutter
1. UnplasticizedPolyvinylChloride(PVC-U)fittingsforRainwaterGutteranddownpipes
For updated copies of our certificates, please visit the Paling website www.paling.com.my
1. UnplasticizedPolyvinylChloride(PVC-U)Rainwaterdownpipesroundandrectangularshape
qualiTy & CErTiFiCaTiON
SySTEm CErTiFiCaTiON
ElEGaNCE raiNGuTTErS /// aCCrEdiTaTiON
7
STANDARDS AND QUALIFICATION
BSEN 607 for gutter and BSEN 1462 for gutter bracket
GUTTER PROFILE PRINTINGA The word ‘Paling’ or Paling
logoB The word ‘ELEGANCE’C The word SIRIM CERTIFIED or
MS logoD SIRIM license numberE Standard conformance
and year of standardF Manufacturing dateG Manufacturing shift code
DOWNPIPE FITTINGS1 Round Straight Coupler2 Round Downpipe Clip3 Round Downpipe4 Round Bend 68°5 Rectangular Bend 88°6 Rectangular Downpipe Clip7 Rectangular Downpipe8 Rectangular Offset 88°9 Rectangular Straight Coupler
GUTTER FITTINGSMARKINGH Product nameI StandardJ Paling logo
6
7
8
9
STANDARDS & QUALIFICATION /// ELEGANCE RAINGUTTERS
H
I
J
8
STOP ENdCOdE NO. dirECTiON
milKy WHiTE
TrENdyGrEy
2705205LE01 2705205LE22 left
2705205RI01 2705205RI22 right
COdE NO. dimENSiONS(mm)
lENGTH(m)
milKy WHiTE
TrENdy GrEy
a b C
15002055801 15002055822 205 125 424 5.8
GuTTEr PrOFilE
A
B
C
ExPaNSiON OuTlET
COdE NO. OuTlET SiZE
(mm)
SHaPE dimENSiONS
(mm)
milKy WHiTE
TrENdyGrEy
a b
271011001 271011022 110 round 341 238
271011501 271011522 110 rectangular 341 238a
b
iNTErNal COrNEr
COdE NO. dimENSiONS (mm)
milKy WHiTE
TrENdy GrEy
a b
270320501 270320522 227 227a
b
ExTErNal COrNErCOdE NO. dimENSiONS (mm)
milKy WHiTE
TrENdy GrEy
a b
270220501 270220522 227 227A
B
ElEGaNCE raiNGuTTErS /// raiNGuTTEr & FiTTiNGS
9
ExPaNSiON JOiNErCOdE NO.
milKyWHiTE
TrENdy GrEy
270920501 270920522
JOiNErCOdE NO.
milKyWHiTE
TrENdy GrEy
270620501 270620522
iNTErNal braCKETCOdE NO.
milKyWHiTE
TrENdy GrEy
270720501 270720522
raiNGuTTEr & FiTTiNGS /// ElEGaNCE raiNGuTTErS
GraTiNG COdE NO.
milKy WHiTE TrENdy GrEy
270820501 270820522
COdE NO. dimENSiONS (mm)
l l1 l2 d d1
271411501 52 50 122 115 90
STraiGHT COuPlEr (Rectangular)
L1L
D1
D
L2
10
68° BEND (Rectangular)
CODE NO. ANGLE DIMENSIONS (mm)Ѳ L L1 D D1
2713 115 01 68º 52 50 115 90
D D1
L
L1
88° BEND (Rectangular)
CODE NO. ANGLE DIMENSIONS (mm)Ѳ L L1 D D1
2711 115 01 88º 52 50 115 90
D D1
L
L1
OFFSET 88° (Rectangular)
CODE NO. ANGLE DIMENSIONS (mm)Ѳ L L1 D D1
2712 115 01 88º 52 50 115 90
DOWNPIPE CLIP (Rectangular)
CODE NO. DIMENSIONS (mm)D D1
2704 115 01 115 90
D
D1
ELEGANCE RAINGUTTERS /// RAINGUTTER & FITTINGS
DOWNPIPE CLIP (ROUND)
CODE NO. DIMENSIONS (mm)D
2701 110 01 110
D
11
RAINWATER PIPES /// ELEGANCE RAINGUTTERS
RECTANGULARDOWNPIPE
CODE NO. LENGTH(m)
MIN.WALL THICKNESS e (mm)
DIMENSIONS(mm)
D D11510 115 58 01 5.8 1.7 115 90
D
D1
RAINWATER PIPESThere are three types of rainwater pipe:
• The Normal Duty Pipe is intended for exposed installation on the building that do not exceed storeys in height, such as terrace houses or low-rise shop-houses.
• The Medium Duty is intended for exposed installation on building exceeding five storeys.• The Heavy Duty designed with higher ring stiffness for use in pipe work to be encased in
reinforced concrete (RC) columns.
D
L
CODE NO. MODEL NOM. SIZE
SPECIFICATION OUTSIDE DIAMETER
WALL THICKNESS
LENGTHL
(mm) D (mm) e (mm) (m)1220 110 58 ND 01 Normal Duty 110 110.0-110.3 2.2-2.7 5.8
1220 110 58 MD 01 Medium Duty 110 110.0-110.3 3.2-3.8 5.8
1220 110 58 HD 20 Heavy Duty 110 110.0-110.3 6.0-6.8 5.8
12
COdE NO. dESCriPTiON GmS TiN/CarTON
6050070P PalingClearsolvefastdry 500 20
6010070 PalingClearsolvefastdry 100 60
6050010 PalingColoursolveslowdry
(Blue)
500 20
6050012 PalingColoursolvefastdry
(Green)
500 20
6050011 Elegancesolventcement
(rainwatergutter)
500 20
SOlVENT CEmENT
ElEGaNCE raiNGuTTErS /// SOlVENT CEmENT
13
FEaTurES• PVCSolventCementFastDry–forpipesandfittings
≤80mm
• PVCSolventCementSlowDry–forpipesandfittings ≥80mm
• Moderatesolventodour
• ComplieswithMS628orBS4346.SPANlisted
adVaNTaGES• ColourCo-PolymerforEasierApplicationand
Inspection
• EasytoUse
• PremiumQuality
• FastandSlowDryingSolventavailableforStrongBonding
aPPliCaTiONPalingSolventCementisformulatedforPVCpipesusedforrainwaterandraingutterapplications.
SOlVENTcement
Product range
SOlVENT CEmENT /// ElEGaNCE raiNGuTTErS
14
Solid Content: 24%Consistency property: 1,000 pcsquality: Tough & resilientSolid consist of: mEK & CyCColour: GreenStandard: mS628 Part ii Section 2.2
- HighlysolublefastdryPVC-USolventcement.
- SuitableforjoiningallPVC-Upipesfrom15mm-75mm
diameter.
- Whenapplied,itwillinstantlydissolveandblendwiththe
pipetoproduceafilm(wall)of0.4mmthick,sothatthe
fittinggapwillbestrongandstable.
STraiNiNG TimE
Pipes with diameters 15mm 10 seconds
Pipes with diameters 25mm to 32mm 8 seconds
Pipes with diameters 50mm 6 seconds
Pipes with diameters 75mm 4 seconds
PaliNG COlOurSOlVE FaST dry
PaliNG raiNGuTTErS SOlVENT CEmENT
PaliNG COlOurSOlVE SlOW dry
Solid Content: 24%Consistency property: 1,000 pcsquality: Tough & resilientSolid consist of: mEK, CyC & THFColour: blueStandard: mS628 Part ii Section 2.2
- HighlysoluableslowdryPVC-USolventcement.
- SuitableforjoiningallPVC-Upipesfrom75mm-200mm
diameter.
- Whenapplied,itwillinstantlydissolveandblendwiththe
pipetoproduceafilm(wall)of0.4mmthick,sothatthe
fittinggapwillbestrongandstable.
STraiNiNG TimE
Pipes with diameters 25mm 20 seconds
Pipes with diameters 32mm to 50mm 16 seconds
Pipes with diameters 75mm to 100mm 12 seconds
Pipes with diameters 150mm 8 seconds
Pipes with diameters 200mm 4 seconds
Solid Content: 24%Consistency property: 1,000 pcsquality: Tough & resilientSolid consist of: mEK, CyC & THFColour: Transparent and ClearStandard: mS628 Part ii Section 2.2
- SuitableforjoiningallPVC-Upipesraingutter.
- Whenapplied,itwillinstantlydissolveandblendwiththe
pipetoproduceafilm(wall)of0.4mmthick,sothatthe
fittinggapwillbestrongandstable.
STraiNiNG TimE
Gutter Profile 30 seconds
aTTENTiON:
1. Temperaturebelow15°C(50°F)willextendthe
strainingperiodforapproximately5minutesfor
eachtypeofpipe.
2. Alltheabovesolventcementisnotapplicable
tothosePVC-Upipeorfittingwhicharemade
ofpartlyrecycledmaterial.
3. Afterassembly,thepipemustbetightlyheld
inplaceandshallonlybereleasedafter
recommendedstrainingtimeasstipulated.If
releaseprematurely,thepipetobefittedwill
spring apart.
PaCKiNG CTN. SiZE
500g.(withbrush)x20Tinsperctn. 508mmx220mmx225mm
ElEGaNCE raiNGuTTErS /// raiNWaTEr dOWNPiPES
15
NOmiNal SiZE OF PiPE Or FiTTiNG
amOuNT OF SOlVENT CEmENT rEquirEd PEr JOiNT
NO OFPOSSiblE JOiNTS
(mm) (g) 100 g 500 g15 1.3 76 383
20 2.0 55 250
25 2.5 40 200
32 3.2 30 156
40 5.0 20 100
50 7.2 13 69
80 12.0 8 41
100 15.5 6 32
155 26.0 2 19
200 49.0 1 10
SOlVENT CEmENT rEquirEmENT FOr PVC-u PiPES & FiTTiNGS
SOlVENT CEmENT rEquirEmENT FOr PVC-u GuTTErS & COmPONENTS
rECOmmENdaTiONS ON bruSH: PrESSurE TEST:
PHySiCal aNd CHEmiCal PrOPErTiES
SiZE (mm) amOuNT OF SOlVENT CEmENT rEquirEd PEr JOiNT (g) NO OF POSSiblE JOiNTS (500 g)
205x125 15.5 32
A: Pipeswithdiameter25mmandbelow-usebrushas
accompaniedandaffixedtocan
B: Pipeswithdiameter32mmto50mmandbelow
-use1"brush
C: Pipeswithdiameter75mmto200mmandbelow-use
2"brush
D: RainWaterGutterandComponents-usebrushas
accompaniedandaffixedtocan
Flash point: 15°C
Flammable mixture (uN No. 1133)Thissolventcementmaterialwilligniteatambient
temperatures.Colourlessvapoursmaytravelconsiderable
distancetoignitionsourcesandcauseflashfiresor
explosions.
Hazard IdentificationMaycauseeyesandskinirritation,burnsordermatitis.
StorageStoreinwell-ventilatedarea.Keepawayfromheat,sparks
andflame.
Safety advice- Keepoutofreachofchildren.
- Keepawayfromsourcesofignition-NoSmoking.
- Avoidcontactwitheyes.
- Incaseoffire,usechemicalpowder,foamorcarbon
dioxide.
raiNWaTEr dOWNPiPES /// ElEGaNCE raiNGuTTErS
TEST PrESSurE dryiNG TimE
ColdWater(20°C) Below12kg/cm2(171psi) After1hour
HotWater(60°C) Below12kg/cm2(171psi) After2hours
16
iNSTallaTiON GuidES aNd TiPS
THEFOLLOWINGfactS have to be determined before the iNSTallaTiON StartS
TheEffectiveroofareaThenumberandpositionofoutletsTheanglesandtheirdistancesfromoutletsTotalnumberofbracketsandfittingsLowpointsoftheinstallation (expansionoutletfixingpoint)
Highpointsoftheinstallation
The effective roof areaTheEffectiveRoofArea(ERA)canbedeterminedbyusingthefollowingcalculations:
OptionSimpleCalculationFormula OptionMultiplicationCalculationFormula
Thetablebelowprovidesawiderrangeoffactorsto
enableaccurateassessmentofeffectiveroofareatobe
determined.TheaverageERAof100m2requiresatleastone
expansionoutlet.Therefore3expansionoutletsareneeded
forexampleA.
ExampleA
Usingroofdimensionswitha30°roofpitch.
R1:4mx16mx1.288=82.4m2
R2:4mx16mx1.288=41.2m2
R3:4mx16mx1.288=30.9m2
R4:4mx16mx1.288=30.9m2
R1:(4m+2.3/2)x16m=82.4m2
R2:(4m+2.3/2)x8m=41.2m2
R3:(4m+2.3/2)x6m=30.9m2
R4:(4m+2.3/2)x6m=30.9m2
roof pitch Factor
10° 1.088
12.5° 1.111
15° 1.134
17.5° 1.158
20° 1.182
22.5° 1.207
25° 1.233
27° 1.260
30° 1.288
32.5° 1.319
35° 1.350
37.5° 1.384
40° 1,419
42.5° 1.459
45° 1.500
47.5° 1.547
For roofs of 50° and above, a factor of 1.600 may be used
ElEGaNCE raiNGuTTErS /// iNSTallaTiON GuidEliNES
17
iNSTallaTiON GuidES
it is important to read Entire instructions Prior to attempting any installation!
To obtain the maximum benefits, it is essential that you have the right quantity of components and parts before assembling to save time and effort.
required Equipment1.Hammer
2.Hacksaw
3.Powerdrill
4.Cloth
5.Stringline
6.Builderslevelorlinelevel
7.Ladder
18.Planks
19.Measuringtape
10.Pencil
11.Graphpaper
12Squareandrule
13.Screws
14.EleganceSolventCement
STEP 1Measureanduseaplanningguidetosketcharoofplan(1centimetre=1metre).
Determinethefittingsrequiredandtransfertheinformationtotheordersheet.
Thiswillenableyoutocalculatethecostofmaterialsrequiredtocompletethe
installation.Also,decidewhereyouwantyourdownpipe.Theeffectiveroofarea
of100m2requiredaminimumofoneexpansionoutlet.Largereffectiveroofarea
willrequiremoreexpansionoutlets.PALING’sElegance isavailablein4metre
and6metrelengths.
layOuT PlaN ViEW
STEP 2Measuretherooflinewherethegutter
willbeinstalled,addingtogetherthe
lengthsofeachfasciaboard.Takethe
measurementfromtheouteredge
oftheshingle(FigureA).Markthe
measurementsandmakeanoutline
onagraphpaper.
Next,markthelocationsofthe
downpipeswitha‘X’.(FigureB)
Alltherepaintingforthefascia
boardshouldbecompletedbefore
Elegance installationiscarriedout.
Figure B
iNSTallaTiON GuidEliNES /// ElEGaNCE raiNGuTTErS
18
20mm thickFascia Board
Gutter
STEP 3Driveanailintothefasciaboardatone
endofthegutter-run(FigureC).The
roofeavesbeyondthefasciaboard
shouldbenotbelessthan50mmor
greaterthan75mmtoensurecorrect
roofwaterdischargeintothegutter.
Stretchastringlinefromthenail.To
properlyaligntheslope(usingaline
levelonthestringline)droponeendof
thelineaquarter-inchforevery10feet
offasciaboardlength,thenmarkthat
pointwithapencil(FigureD).
STEP 5Laygutterprofilesandtheirfittings
onthegroundasthemodelforhow
theywillgoonthefasciaboard.Use
hacksawtocutthegutterstothe
requiredlength(FigureG)andremove
allburrsatthecutend.ApplyPALING’s
SolventCementtothejoiningsections
andsealthosesectionsaccordingly
(FigureH).Checktheweldedsections
toensurethattheyarecompletely
sealedtogether.Ensuresufficient
solventcementisusedforjoining.
Wipeoffexcesssolventcementwitha
cleanclothimmediately.
STEP 4Determinethelowestpoint,and
attachtheexpansionoutlettothe
fasciaboardbyusingapowerdrill
(FigureE).Alongthegutterrun,placed
theinternalbracketsatevery600mm
interval(FigureF).Inordertosupport
thefittings(joiner,internal&external
corner,stopendandexpansion
outlet),internalbracketsshouldbe
fixedatadistanceof150mmfrom
eachendofthefittings.
Figure D
Figure C
Figure F
Figure E
Figure H
Figure G
ElEGaNCE raiNGuTTErS /// iNSTallaTiON GuidEliNES
19
STEP 6Toapplythegutterprofilestothe
fasciaboards,positiontheP-shape
interlockoftheguttereachthe
bracketends.Afterensuringeach
bracketiscorrectlyengagedintothe
P-shapeinterlock,rollguttersection
evenlyupwardstowardsthebracket
untilthereartopedgefirmlylocksinto
thebracket(FigureI).Neversolvent
weldthegutterwiththeexpansion
outletsasthegutterneedstomove
freelytoaccommodatethermal
expansion(FigureJ).
STEP 7Aseriesofselectionfittingsare
assembledtodiverttherainwater
tothedrainagesystem.Installpipe
clipsatevery1.8mintervalalongthe
downpipes(FigureK&L).
iNSTallaTiON GuidES
PaliNG’s formulated Solvent Cement to be used with Elegance system. The surface areas to be joined must be clean and dry before application. apply solvent cement on both surfaces and join them accordingly. Hold the joining parts together for a minimum of 10 seconds. Check
Theweldedsurfacestoensurethatacompletesealhas
beenachieved.Excesssolventcementontheexterior
surfaceshouldberemovedimmediately.
(NootherSolventCementshouldbeusedwithout
consultationwiththemanufacturer.)
Figure I
Figure J Figure K
iNSTallaTiON GuidEliNES /// ElEGaNCE raiNGuTTErS
20
APPLICATION SOLUTION
The Elegance expansion joiner is specially designed for addressing substantial movement from thermal expansion/contraction resulting from installation of long and straight gutter.
The application is normally suitable for the run of gutter length exceeding 8 metres and without any incorporation of expansion outlet.
It is also intended for gutters running along multiple corners, without thermal movement provision.
Utilizing the expansion joiner in such installation will prevent gutters from warping, bowing and dislocating, resulting in a fairly straight and neat
ELEGANCE RAINGUTTERS /// INSTALLATION GUIDELINES
21
PrOPriETy FEaTurES
TheEleganceexpansionjoinerisequippedwithdoubleslidingrubberseal(3),whichaccommodatesandfacilitatesthemovementofthegutters(1),(2).
Thedualsealdesignenhancesreliabilityagainstleakageduringnormalorheavyrainfallrate.
Sealmaterialismadeofresilientanddurabletoweatheringeffect.
Thesealsinsidetheexpansionjoinercanbeeasilycleanedorreplaced,intheeventofdamage,byremovingthe2partsof
theunit(lubricatethegasketwithsilicongreaseaftercleaningorreplacementbeforereassembling).Thecompleteunitis
pre-lubricatedatfactory.
iNSTallaTiON GuidEliNES /// ElEGaNCE raiNGuTTErS
1 3
2
Thejoinerisinherently
markedwithtemperature
scaletopreciselyposition
gutteraccordingtoambient
temperature
(range-10°Cto40°C)
22
TofixtheEleganceexpansionjoinerissimpleandswift.Thestepsoutlinedbelowguidestheinstallation:
• Setbracketspacingat400mmandplacethejoineratmiddistancebetweenthesebrackets.
• SolventCementthegutterintoonesideoftheExpansionJoinerandinsertintopreviouslyinstalledbrackets.
• Settheexpansionjoinerusingthegraduatedtemperaturemarkedontheinsideofthebaseofthefittingaccordingtothe
temperatureatthetimeoftheinstallation.Itisimportantthatthefittingissetintherightpositionforittofunctioncorrectly.
• Determinethelengthofthenextpieceofgutter.SolventCementthislengthofgutterintotheothersideoftheexpansion
joiner,ensuringthejoinerisstillsetatthecorrecttemperatureposition.
iNSTallaTiON
TECHNiCal daTa
dimENSiONS (mm)
L(Open) 190
L(Close) 145
H1 148
H2 130
W 210
ElEGaNCE raiNGuTTErS /// iNSTallaTiON GuidEliNES
l
W
H1H2
23
-3-aPPly THE SOlVENT
CEmENTApplyadhesiveevenlytobothsidestobematedusingabrushingstrokeparalleltooralongthepipeaxis.Itisrecommendedthata1”brushbeusedtoapplythesolventcement
can or tin well before using to ensure homogeneity.
-4-maKE THE JOiNT
Insertpipestraightintothefittingasdeeplyintothefittingsocketaspossiblewithouttwistingandholdinplacefirmly
andsteadilyforatleasttensecondsforFastDryandtwentysecondsforSlowDry.
Removeexcesssolventcementwithasoftcloth.Asmallclosedadhesiveringshouldbeclearlyvisibleattheendofthefittingtosignalthatthesufficientadhesivehasbeen
applied.
-5-ClEaN THE ExCESS SOlVENT
CEmENTWhenmakingmultiplejointsonapipingsystem,
anundisturbedrestperiodofatleastfiveminutesisrequiredbeforesecondbondcanbecarriedout.Thisistoavoidstresstothefirstjoint,whichmayweakenits
adhesion.
Wait 24 hours before testing or use
-2-dEGrEaSE THE SPiGOT
aNd SOCKETMarktheinsertiondepthtothepipespigottoavoidexcessiveapplicationandprovidescontrolastowhetherpipehasbeenadequatelyinserted
intothefitting.
Cleanpartstobefusedwithprimingfluidtoensurethatdirtandpossibleslipandreleaseagentsareremovedforoptimalresults.ScrapeoffanydiscolouredpipelayerduetoUV-radiationorproperbondingcannot
beachieved.
forpipeswithdiametersbetween32to50mmand2”brushforpipeswithdiametersabove50mm.Jointmustbemadewithin2minutesofstarting
application.
-1-CuT & dEburr
Wherenecessary,cutpipetolengthatrightangletoitsaxistomaximizesurfaceforbonding.Useofamitreboxandfinetoothsawis
recommended.
Cutsurfaceneedtobedeburredandchamferedtoaslightbeveltosimplifycentredinsertionanduniformadhesivedistribution
between parts.
aSSEmbly PiPES WiTH SOlVENT CEmENT JOiNTS
iNSTallaTiON GuidEliNES /// ElEGaNCE raiNGuTTErS
24
PrOJECT rEFErENCES
TamaN yarl @ Sri PETaliNGmilKy WHiTE
liNK HOuSE@ KaJaNGlEaTHEr brOWN
adda HEiGHT@ JOHOrTrENdy GrEy
ElEGaNCE raiNGuTTErS /// PrOJECT rEFErENCES
Aliaxisispresentinmorethan40countries.TheGrouphasmorethan100manufacturingandcommercialentitiesandemploysover14,600people.
TheethosoftheGroupallowslocalandglobalknowledgeoftheindustry,regulationsandbuildingpracticestocombineandprovideconsistentlyexcellentcustomerservicetospecifiers,consultants,contractors,installersandothers.
THE aliaxiS GrOuP iS a lEadiNG GlObal maNuFaCTurEr aNd diSTribuTOr OF Primary PlaSTiC Fluid HaNdliNG SySTEmS uSEd iN rESidENTial aNd COmmErCial CONSTruCTiON.
THE aliaxiS GrOuPabOuT
iN aSia
malaysia:KualaLumpur
Vietnam:HoChiMinh
india:Bangalore,Mumbai&Goa
Singapore
China:Beijing,Shanghai&Guangzhou
abOuT
PaliNG iNduSTriES SdN. bHd. WaS ESTabliSHEd iN 1971 TO PrOduCE uPVC PiPES & FiTTiNGS iN malaySia. OVEr THE yEarS iT HaS ExPaNdEd iTS raNGE TO OTHEr SaNiTary PrOduCTS aNd SySTEmS liKE PlaSTiC CiSTErNS aNd OTHEr aCCESSOriES.
PaliNG iNduSTriES
Thesesystemsaresuitableforvariousapplicationsandbuildingtypes,includingdomestic,commercial,industrialandcivilconstructionprojects.Palingproductsareaccuratelydesignedtoconsistentlyexceedtheperformanceaspectsspecifiedunderwidelyrecognizedstandards.
AlongwithISO9001certificationandvariousapprovalsbySIRIMandIKRAM,PalingproductsareaccreditedbyNSF,anauthorityinwaterindustrystandards.
Palingproductsaremanufacturedunderaneffectivesystemofinspection,testing,supervisionandcontrol.
25
abOuT uS /// ElEGaNCE raiNGuTTErS
NOTE : : daTE
NOTE : : daTE
NOTE : : daTE
disclaimer
ThisbrochurehasbeencompiledbyPalingIndustriesSdnBhd(“thecompany”)topromotebetterunderstandingofthetechnicalaspectsoftheCompany’s
productstoassistusersinobtainingfromthemthebestpossibleperformance.Thebrochureissuppliedsubjecttoacknowledgmentofthefollowing
conditions:
i) ThebrochureisprotectedbyCopyrightandmaynotbecopiedorreproducedinanyformorbyanymeansinwholeorinpartwithoutpriorconsentin
writingbytheCompany.
ii) Productspecifications,usagedataandadvisoryinformationmaychangefromtimetotimewithadvancesinresearchandfieldexperience.The
Companyreservestherighttomakesuchchangesatanytimewithoutnotice.
iii) CorrectusageoftheCompany’sproductsinvolveengineeringjudgementswhichcannotbeproperlymadewithoutfullknowledgeofalltheconditions
pertainingtoeachspecificinstallation.TheCompanyexpresslydisclaimsallandanyliabilitytoanypersondonebyanysuchpersoninreliancewhether
wholeorpartialuponthewholeoranypartofthecontentsofthisbrochure.
iv) Nooffertotrade,noranyconditionsoftrading,areexpressedorimpliedbytheissueorcontentofthisbrochure.
v) NothinghereinshalloverridetheCompany’sconditionsofSale,whichmaybeobtainedfromtheRegisteredOfficeoranySalesOfficeoftheCompany.
vi) ThisbrochureisandshallremainthepropertyoftheCompany,andshallsurrenderedondemandtotheCompany.
P r e S S u r eP i P i n g S y S t e m
P i P e S y S t e m SSUITABLEFORBUILDINGS,
houSeS and civil conStruction PurPoSeS.
P i P e S y S t e m SSUITABLEFORBUILDINGS,
houSeS and civil conStruction PurPoSeS.
hydrotechtm
mS3MU L T I - L Ay E R P V C - U
undergrounddrainage &SEWER
SyStem
P i P e S y S t e m SSUITABLEFORBUILDINGS,
houSeS and civil conStruction PurPoSeS.
P i P e S y S t e m SSUITABLEFORBUILDINGS,
houSeS and civil conStruction PurPoSeS.
Soil,WASTE&vent SyStem
P i P e S y S t e m SSUITABLEFORBUILDINGS,
houSeS and civil conStruction PurPoSeS.
rainWATERdrainage SyStem
P i P e S y S t e m SSuitable for civil
conStruction PurPoSeS and buildingS.
r a i nWATERSyStem & gyrojoint
Distributed by :
PALING INDUSTRIES SDN BHD (11039 V)
w w w . p a l i n g . c o m . m y
we make life �ow
Lot 10072, Persiaran Mahogani Utama 2 Seksyen 4,
Bandar Utama Batang Kali,
44300 Batang Kali,
Selangor Darul Ehsan.
T : 03 - 6063 6888 03 - 6057 0580F : 03 - 6057 0680E : [email protected]